36C78619B0012-003.pdf
PDF 8 MB Posted
- Solicitation number
- 36C78619B0012
About this file
36C78619B0012 FSNC Upgrade 3001 Plans - 894CM3038-Part2.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C78619B0012-0005001.pdf | ||
| 36C78619B0012-0005000.docx | DOCX document | |
| 36C78619B0012-0004000.docx | DOCX document | |
| 36C78619B0012-0004001.pdf | ||
| 36C78619B0012-0003000.docx | DOCX document | |
| 36C78619B0012-0003001.pdf | ||
| 36C78619B0012-0002002.xlsx | XLSX spreadsheet | |
| 36C78619B0012-0002001.pdf | ||
| 36C78619B0012-0002000.docx | DOCX document | |
| 36C78619B0012-0001000.docx | DOCX document | |
| 36C78619B0012-005.pdf | ||
| 36C78619B0012-002.pdf | ||
| 36C78619B0012-004.pdf | ||
| 36C78619B0012-001.docx | DOCX document | |
| 36C78619B0012-000.docx | DOCX document |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
HENNEPIN COUNTY, MINNESOTA
MARCH 19, 2019 RPP MAC Dwg. of 93
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FORT SNELLING NATIONAL CEMETERY
MAINTENANCE BUILDING 3001 &
MATERIAL HANDLING FACILITY
894CM3038BID DOCUMENTS
KEY MAP
(NOT TO SCALE)
VL111
EXISTING CONDITIONS & BORING
PLAN
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
HENNEPIN COUNTY, MINNESOTA
MARCH 19, 2019 RPP MAC Dwg. of 93
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FORT SNELLING NATIONAL CEMETERY
MAINTENANCE BUILDING 3001 &
MATERIAL HANDLING FACILITY
894CM3038BID DOCUMENTS
KEY MAP
(NOT TO SCALE)
EROSION & SEDIMENT CONTROL PLAN PHASE I EROSION & SEDIMENT CONTROL PLAN PHASE II
GC111
E&S CONTROL PLAN
GC511
E&S CONTROL DETAILS
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
HENNEPIN COUNTY, MINNESOTA
MARCH 19, 2019 RPP MAC Dwg. of 93
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FORT SNELLING NATIONAL CEMETERY
MAINTENANCE BUILDING 3001 &
MATERIAL HANDLING FACILITY
894CM3038BID DOCUMENTS
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
HENNEPIN COUNTY, MINNESOTA
MARCH 19, 2019 RPP MAC Dwg. of 93
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FORT SNELLING NATIONAL CEMETERY
MAINTENANCE BUILDING 3001 &
MATERIAL HANDLING FACILITY
894CM3038BID DOCUMENTS
KEY MAP
(NOT TO SCALE)
CD111
DEMOLITION PLAN
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
HENNEPIN COUNTY, MINNESOTA
MARCH 19, 2019 RPP MAC Dwg. of 93
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FORT SNELLING NATIONAL CEMETERY
MAINTENANCE BUILDING 3001 &
MATERIAL HANDLING FACILITY
894CM3038BID DOCUMENTS
KEY MAP
(NOT TO SCALE)
CS111
SITE & UTILITY PLAN
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
HENNEPIN COUNTY, MINNESOTA
MARCH 19, 2019 RPP MAC Dwg. of 93
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FORT SNELLING NATIONAL CEMETERY
MAINTENANCE BUILDING 3001 &
MATERIAL HANDLING FACILITY
894CM3038BID DOCUMENTS
KEY MAP
(NOT TO SCALE)
CG111
GRADING PLAN
SPECIFICATION SHEET
CU211
UTILITY PROFILES
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
HENNEPIN COUNTY, MINNESOTA
MARCH 19, 2019 RPP MAC Dwg. of 93
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FORT SNELLING NATIONAL CEMETERY
MAINTENANCE BUILDING 3001 &
LP111
LANDSCAPE PLAN
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
HENNEPIN COUNTY, MINNESOTA
MARCH 19, 2019 RPP MAC Dwg. of 93
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FORT SNELLING NATIONAL CEMETERY
MAINTENANCE BUILDING 3001 &
MATERIAL HANDLING FACILITY
894CM3038BID DOCUMENTS
KEY MAP
(NOT TO SCALE)
GI511
GENERAL DETAILS
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
HENNEPIN COUNTY, MINNESOTA
MARCH 19, 2019 RPP MAC Dwg. of 93
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FORT SNELLING NATIONAL CEMETERY
MAINTENANCE BUILDING 3001 &
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
HENNEPIN COUNTY, MINNESOTA
MARCH 19, 2019 RPP MAC Dwg. of 93
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FORT SNELLING NATIONAL CEMETERY
MAINTENANCE BUILDING 3001 &
MATERIAL HANDLING FACILITY
894CM3038BID DOCUMENTS
CU511
STORM DETAILS
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
HENNEPIN COUNTY, MINNESOTA
MARCH 19, 2019 RPP MAC Dwg. of 93
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FORT SNELLING NATIONAL CEMETERY
MAINTENANCE BUILDING 3001 &
MATERIAL HANDLING FACILITY
894CM3038BID DOCUMENTS
1299CGS
APPROX. DRAIN AREA = 60.62 SQ IN
APPROX. WEIGHT WITH FRAME = 40.68 LBS
HINGED GRATE
FOR EASY ACCESS
DIMENSIONS ARE FOR REFERENCE ONLY
ACTUAL DIMENSIONS MAY VARY
DIMENSIONS ARE IN INCHES
GRATE MEETS H-20 LOAD RATING
QUALITY: MATERIALS SHALL CONFORM TO ASTM A536 GRADE 70-50-05
PAINT: CASTINGS ARE FURNISHED WITH A BLACK PAINT
LOCKING DEVICE AVAILABLE UPON REQUEST SEE DRAWING NO.
7001-110-035
1.12
13.56
13.38
3.56 1.81
DRAIN BASIN INLINE DRAIN
THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER
GRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS I,
CLASS II, OR CLASS III MATERIAL AS DEFINED IN ASTM D2321.
BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BE
PLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321.
NON TRAFFIC INSTALLATION
TOP SOIL
GRATE/COVER
TOP SOIL
GRATE/COVER
4" MIN ON 8" - 24"
6" MIN ON 30"
THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER
GRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS I,
CLASS II, OR CLASS III MATERIAL AS DEFINED IN ASTM D2321.
BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BE
PLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321.
CU512
STORM DETAILS
MINIMUM PIPE BURIAL
DEPTH PER PIPE
MANUFACTURER
RECOMMENDATION
INVERT ACCORDING TO
PLANS/TAKE OFF
NYLOPLAST 12" INLINE DRAIN: 2712AG _ _ X
(3) VARIOUS TYPES OF INLET & OUTLET ADAPTERS AVAILABLE:
4" - 12" FOR CORRUGATED HDPE (ADS N-12/HANCOR DUAL WALL,
ADS/HANCOR SINGLE WALL), N-12 HP, PVC SEWER (EX: SDR 35),
PVC DWV (EX: SCH 40), PVC C900/C905, CORRUGATED & RIBBED PVC
(CORRUGATED HDPE SHOWN)
1 - GRATES/SOLID COVER SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05,
WITH THE EXCEPTION OF THE BRONZE GRATE.
2 - FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05.
3 - DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO
ASTM D3212 FOR CORRUGATED HDPE (ADS N-12/HANCOR DUAL WALL),
N-12 HP, & PVC SEWER.
4 - DIMENSIONS ARE FOR REFERENCE ONLY. ACTUAL DIMENSIONS MAY VARY.
5 - DIMENSIONS ARE IN INCHES
6 - SEE DRAWING NO. 7001-110-275 FOR ADS N-12 & HANCOR DUAL WALL BELL
INFORMATION & DRAWING NO. 7001-110-364 FOR N-12 HP BELL INFORMATION.
(B)
THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER
GRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS I,
CLASS II, OR CLASS III MATERIAL AS DEFINED IN ASTM D2321.
BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BE
PLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321.
ADAPTER SIZE B
4" 10.50 6" 11.50 8" 11.50 10" 11.25 12" 6.00
18" MIN WIDTH GUIDELINE
8" MIN THICKNESS GUIDELINE
(1, 2) INTEGRATED DUCTILE IRON
FRAME & GRATE TO MATCH BASIN O.D.
TRAFFIC LOADS: CONCRETE SLAB DIMENSIONS ARE FOR
GUIDELINE PURPOSES ONLY. ACTUAL CONCRETE SLAB MUST BE
DESIGNED TAKING INTO CONSIDERATION LOCAL SOIL CONDITIONS,
TRAFFIC LOADING, & OTHER APPLICABLE DESIGN FACTORS.
SEE DRAWING NO. 7001-110-111 FOR NON TRAFFIC INSTALLATION.
17.50
17.50
1 - SEE DRAWING NO. 7001-110-364 FOR ADS/HANCOR
N-12 HP BELL INFORMATION
2 - DIMENSIONS ARE FOR REFERENCE ONLY
ACTUAL DIMENSIONS MAY VARY
3 - DIMENSIONS ARE IN INCHES
OCCUPANCY
B
AREA NAME
150 SF 00
00 OCC.
2 HOUR FIRE BARRIER PER IBC SECTION 706. OPENINGS
FIRE RATED FOR 90 MINUTES.
EGRESS PATH WITH NAME, SEGMENT LENGTH, AND
DIRECTION INDICATED
IBC OCCUPANCY GROUP
ROOM (NET) AND AREA (GROSS) TAGS INDICATING SQUARE
FOOTAGE / OCCUPANCY LOAD FACTOR, AND RESULTING
OCCUPANCY BELOW
FB
1 HOUR FIRE PARTITION PER IBC SECTION 708. OPENINGS
FIRE RATED FOR 20 MINUTES FOR CORRIDOR PARTITIONS
AND 45 MINUTES FOR OTHER FIRE PARTITIONS.
FP
PATH A
CODE ANALYIS LEGEND
165 EXIT EXIT F
0.2 x 165 = 33" MIN
ACTUAL = 34.25"
EXIT INDICATOR ADVANCED: WITH NAME OF EXIT, TOTAL
OCCUPANTS EXITING INDICATED, SIZE OF OPENING VS
ACUTAL OPENING WIDTH
CODE DATA
1. APPLICABLE CODES & STANDARDS
1.1 INTERNATIONAL BUILDING CODE (IBC), 2015
1.2 NFPA 101, LIFE SAFETY CODE, 2015
1.2 NATIONAL CEMETERY ADMINISTRATION DESIGN GUIDE, 1999
1.3 ARCHITECTURAL BARRIERS ACT (ABA), 2015
1.4 VA PHYSICAL SECURITY REQUIREMENTS, 2015
1.5 VA FIRE DESIGN MANUAL, 2015
1.6 VA BARRIER FREE DESIGN, 2017
1.7 VA SIGNAGE DESIGN MANUAL, 2015
4. MINIMUM CONSTRUCTION TYPE
4.1 TYPE II-B
3. BUILDING HEIGHT & AREA LIMITATIONS - IBC CHAPTER 5
3.1 TABLE 504.3 ALLOWABLE HEIGHT = 55', ACTUAL = 26'-6"
3.2 TABLE 504.4 ALLOWABLE STORIES ABOVE GRADE = 2, ACTUAL = 1
3.3 TABLE 506.2 ALLOWABLE AREA = 17,500 SF, ACTUAL = 3,880 SF
5. FIRE RESISTIVE REQUIREMENTS - IBC CHAPTER 6
5.1 PRIMARY STRUCTURAL FRAME = 0-HOUR RATING
5.2 BEARING WALLS, EXTERIOR = 0-HOUR RATING
5.3 BEARING WALLS, INTERIOR = 0-HOUR RATING
5.4 NON-BEARING WALLS & PARTITIONS, EXTERIOR = 0-HOUR RATING
5.5 NON-BEARING WALLS & PARTITIONS, INTERIOR = 0-HOUR RATING
5.6 FLOOR CONSTRUCTION = 0-HOUR RATING
5.7 ROOF CONSTRUCTION = 0-HOUR RATING
6. MEANS OF EGRESS - NFPA CHAPTER 42
6.1 EGRESS CAPACITY - TABLE 7.3.3.1 = 0.2" PER OCCUPANT X 39 OCCUPANTS =
7.8" REQUIRED, 68" PROVIDED
6.2 MINIMUM NUMBER OF EXITS - 42.2.4.1 = 2 REQUIRED, 2 PROVIDED
6.3 MINIMUM WIDTH OF DOORS - 7.2.1.2.3.2 = 32", 34" PROVIDED
6.4 COMMON PATH OF TRAVEL - TABLE 42.2.5 = 50', ACTUAL = 0'-0"
6.5 TRAVEL DISTANCE TO EXITS - TABLE 42.2.6 = 200', ACTUAL = 26'-0"
6.6 DEAD END CORRIDORS - TABLE 42.2.5 = 50', ACTUAL = 0'
2. OCCUPANCY CLASSIFICATIONS - IBC CHAPTER 3
2.1 GROUP S-1 STORAGE
3880 SF
MATERIAL STORAGE
E X
IT
B
.2 x
" M
IN
A C
T U
A L
E X
IT
A
.2 x
.8
" M
IN
A C
T U
A L
OCCUPANCY
S-1PATH A
PATH B
MARCH 19, 2019
Location
Project Number
Drawing Number
Project Title
Issue Date Checked Drawn
HENNEPIN COUNTY, MINNESOTA
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FORT SNELLING NATIONAL CEMETERY
MAINTENANCE BUILDING 3001 &
MATERIAL HANDLING FACILITY
894CM3038BID DOCUMENTS
LEO A DALY
(612) 338-8741
ECS MID-ATLANTIC, LLC
(847) 279-0366
O'CONNOR CONSTRUCTION
MANAGEMENT, INC.
(202) 299-0530
CULTURAL RESOURCE ANALYSTS, INC.
(859) 252-4737
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
GORDON - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
GORDON
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:_____________________________
Typed or Printed Name:__________________
Date:__________ License Number:_________
John R. Guerber
03/19/19 52755
LIFE SAFETY PLAN
GI111
JMH JRG 80
LIFE SAFETY ANALYSIS - AREA SCHEDULE
NAME AREA USE CLASSIFICATION (2015 IBC, TABLE 1004.1.2)
DESIGN OCCUPANT LOAD
LOAD
FACTOR
GROSS OR
NET
OCCUPANTS
LEVEL 1
MATERIAL STORAGE 3880 SF Industrial Areas 100 SF Gross 39
Grand total 3880 SF 39
EGRESS PATH SCHEDULE
PATH NAME TRAVEL DISTANCE
MAXIMUM
ALLOWABLE
PATH A 26'-0" 200'-0"
PATH B 26'-0" 200'-0"
SCALE: 1/16" = 1'-0"
E9
LIFE SAFETY PLAN
B
A
59'-4"
64'-0"
1'-0"
11'-8"
1'-0"
11'-8"
1'-0"
11'-8"
1'-0"
11'-8"
1'-0"
11'-4"
1'-0"
1'-0"
1'-0"
6" CONCRETE SLAB ON GRADE
REINF W/ #4 EPOXY COATED @
16"OC EW
TSE = VARIES
SEE NOTES 9-11 FOR ADDL INFO
TFE = 94'-8"
TYP, UNO
14'-0"
B1
SB501
SIM
TYP
20'-8"
23'-4"
15'-4"
5'-0"
5'-0"
15'-4"
23'-4"
20'-8"
D4
SB501
D4
SB501
D2
SB501
D2
SB501
D2
SB501
D2
SB501
D1
SB501
TYP OF 4
WARP FLOOR TOWARD DOOR
W
AR
P
FL
O O
R T
O W
AR
D
D O
O R
TSE = 100'-0"
AT DOORS
TSE = 100'-0"
AT DOORS
TSE = 100'-3"
S
LO
P E
FLO
O
R
S
LO
P E
FLO
O
R
SLOPE FLOOR AT EACH
STORAGE ENCLOSURE, T
YP
FOUNDATION PLAN NOTES
1. FOR GENERAL STRUCTURAL NOTES SEE DRAWING SS001
2. FOR SLAB CONSTRUCTION (CJ) & CONTROL (CJT) JOINTS SEE
3. PROVIDE THICKENED SLAB BELOW INTERIOR CMU PARTITIONS ON CONCRETE
FLOOR SLABS. FOR THICKENED SLAB DETAIL SEE
4. FOR BELOW GRADE UTILITY LINES AT BUILDING PERIMETER PROVIDE THICKENED
CONTINUOUS FOOTING PER DETAIL IF CONDITIONS AT UTILITY LINES
REQUIRE ALTERNATE METHODS NOTIFY CONTRACTING OFFICER
5. RECESS CONC SLAB AS REQUIRED AT FLOOR DRAINS. SEE ARCHITECTURAL FLOOR
PLANS AND FINISH SCHEDULE FOR LOCATIONS.
6. PROVIDE VAPOR RETARDER BELOW SLABS - SEE
7. PROVIDE STONE BASE BELOW SLABS PER
8. FOR CORNER BAR DETAIL- SEE
9. FOR SLAB WARMING SYSTEM (ALTERNATE 4) - SEE MECH. FOR UNDERFLOOR RIGID
INSUL - SEE ARCH
10. BASE BID: PROVIDE 7 LBS/CUBIC YARD FIBER REINFORCING IN FLOOR SLAB.
PROVIDE HEAVY DUTY METALLIC FLOOR HARDENER FINISH.
11. ALTERNATE 2: OMIT FIBERS & METALLIC FLOOR HARDENER. PROVIDE 6" CONCRETE
SLAB W/ #4 @16" OC TOPPED WITH 1 1/2" HIGH STRENGTH CONCRETE/AGGREGATE
TOPPING (EUCO FLOOR 202 BY EUCLID OR EQUAL)
/B1 SB501
/D2 SB501
/B7 SB501
/B5 SB501
/B5 SB501
/C9 SB501
MARCH 19, 2019
Location
Project Number
Drawing Number
Project Title
Issue Date Checked Drawn
HENNEPIN COUNTY, MINNESOTA
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FORT SNELLING NATIONAL CEMETERY
MAINTENANCE BUILDING 3001 &
MATERIAL HANDLING FACILITY
894CM3038BID DOCUMENTS
LEO A DALY
(612) 338-8741
ECS MID-ATLANTIC, LLC
(847) 279-0366
O'CONNOR CONSTRUCTION
MANAGEMENT, INC.
(202) 299-0530
CULTURAL RESOURCE ANALYSTS, INC.
(859) 252-4737
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
GORDON - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
GORDON
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456 03/19/19
Ahmet Senyurekli
47166
I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the state of Minnesota.
Signature:_____________________________
Typed or Printed Name:__________________
Date:__________ License Number:_________
FOUNDATION PLAN
SB111
AXS DJF 81
SCALE: 1/4" = 1'-0"
F1
FOUNDATION PLAN
N
2'
SCALE : 1/4" = 1'-0"
0 4' 8'
B
A
11 5/8" C M
U
5'-6 3/8"
9 EQ
SPA
5'-8"O
C
5'-6 3/8"
11 5/8" C M
U
59'-4"
64'-0"
DBE = 126'-0"
DBE = 124'-8"
SLOPE DOWN
D E
C K
S P
A N
1 1/2" 22GA TYPE B
METAL ROOF DECK
EL = VARIES
32LH10
32LH10
32LH10
32LH10
32LH12
32LH12
32LH12
32LH10
32LH10
32LH10
ERU-1
2491 LBS
C1
SF501
B9
SF501
B9
SF501
C1
SF501
SF501
B5
11 5/8" C
MU
11 5/8" C
MU
ROOF FRAMING PLAN NOTES
1. FOR GENERAL STRUCTURAL NOTES SEE DRAWING SS001
2. DBE INDICATES DECK BEARING ELEVATION.
3. FOR OPENINGS THROUGH ROOF SEE MECHANICAL DRAWINGS.
PROVIDE ROOF FRAME AT EACH OPENING SEE
4. TYPICAL ROOF DECK FASTENING: 5/8"Ø PUDDLE WELD IN 36/7 PATTERN.
PROVIDE 1 SIDELAP SCREW EACH SPAN. SEE SPECIFICATIONS FOR ALTERNATE
DECK FASTENING METHODS.
5. JOISTS TO BE DESIGNED FOR WIND UPLIFT SEE DETAIL
6. WHERE JOIST CHORD CONCENTRATED LOADS DO NOT OCCUR WITHIN 0'-6" OF
PANEL POINT, REINFORCE JOIST PER
7. FOR LATERAL LOADS TO JOIST SEATS SEE
/B1 SF501
/B9 SS001
/B2 SF501
/B4 SF501
MARCH 19, 2019
Location
Project Number
Drawing Number
Project Title
Issue Date Checked Drawn
HENNEPIN COUNTY, MINNESOTA
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FORT SNELLING NATIONAL CEMETERY
MAINTENANCE BUILDING 3001 &
MATERIAL HANDLING FACILITY
894CM3038BID DOCUMENTS
LEO A DALY
(612) 338-8741
ECS MID-ATLANTIC, LLC
(847) 279-0366
O'CONNOR CONSTRUCTION
MANAGEMENT, INC.
(202) 299-0530
CULTURAL RESOURCE ANALYSTS, INC.
(859) 252-4737
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
GORDON - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
GORDON
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456 03/19/19
Ahmet Senyurekli
47166
I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the state of Minnesota.
Signature:_____________________________
Typed or Printed Name:__________________
Date:__________ License Number:_________
ROOF FRAMING PLAN
SF111
AXS DJF 82
SCALE: 1/4" = 1'-0"
F1
ROOF FRAMING PLAN
N
2'
SCALE : 1/4" = 1'-0"
0 4' 8'
A E
B
A E
B
A E
D
A E
D
D7
AE311
D7
AE311
B
A
64'-0"
59'-4"
16'-4"
3'-4" 2'-0"
16'-0"
14'-0"
12'-8"
12'-8"
12'-8"
12'-8"
11'-4"
C12
C12
C12
C12
8'-0" H
IG
H
8'-0" H
IG
H
8'-0" H
IG
H
8'-0" H
IG
H
MULCH BIN
SOIL BIN
CLASS 5 BIN
SAND BIN
SALT BIN
DRIVE LANE
SCREENING AREA
107B
106A107A
F7
AE311
F7
AE311
106B
F2
AE311
F5
AE311
AF01
TYP
AE511
D6
ABOVE
16'-0"
2'-0"
3'-4"
16'-4"
AF02
AF03
AF03
AF03
MECH
8'-0"
12'-0"
M8
M8
10'-0" HIGH
10'-0" HIGH
FD
FD
FD
FD
1S4A
FIRE RATING
1 = 1 HOUR
MATERIAL
C = CONCRETE
S = STUD
M = CMU
NOMINAL THICKNESS
1 = 1 5/8" 2 = 2-1/2" 4 = 3-5/8" 6 = 6" 8 = 8" 10 = 10"
OPTIONS
H = PARTIAL HEIGHT WALL
1. ALL PARTITIONS GO TO DECK UNLESS NOTED OTHERWISE.
2. PROVIDE WATER RESISTANT GWB AT ALL WET LOCATIONS.
3. PROVIDE CEMENTITIOUS BACKING PANELS AT WALL TILE
LOCATIONS.
NOTES
PARTITION TYPES
FLOOR PLAN NOTES
1. PENETRATIONS THROUGH NON-RATED FLOORS, WALLS AND OTHER ASSEMBLIES
SHALL BE SEALED AT BOTH SIDES WITH MATERIALS APPROPRIATE TO THE
ASSEMBLY CONSTRUCTION TO REDUCE SOUND TRANSMISSION.
2. PENETRATIONS THROUGH FIRE-RATED FLOORS, WALLS, AND OTHER ASSEMBLIES
SHALL BE PROTECTED BY MATERIALS AND INSTALLATION DETAILS THAT
CONFORM TO UL OR OTHER APPROVED LISTINGS AND MATCH THE RATING OF
THE CONSTRUCTION BEING PENETRATED.
3. PROVIDE BLOCKING AS REQUIRED TO SUPPORT WALL MOUNTED ITEMS
(INCLUDING, BUT NOT LIMITED TO, MARKER BOARDS, SIGNAGE, CASEWORK,
MILLWORK AND TOILET ACCESSORIES).
4. PROVIDE BLOCKING AT RAILINGS AND GUARDRAILS CAPABLE OF SUPPORTING
THE POINT AND UNIFORM LOADS REQUIRED BY CODE.
5. VERIFY CLEARANCES REQUIRED FOR INSTALLATION OF RECESSED OR SEMI-
RECESSED EQUIPMENT AND FIXTURES (E.G. CABINETS, DISPENSERS, PANELS,
ETC.). NOTIFY CONTRACTING OFFICER IMMEDIATELY IF SPECIFIED WALL TYPES
DO NOT PROVIDE ADEQUATE SPACE FOR PROPER INSTALLATION.
6. FLOOR PLAN DIMENSIONS ARE LOCATED FROM THE FINISHED FACE OF
PARTITIONS, UNLESS NOTED OTHERWISE.
7. MASONRY DIMENSIONS ARE NOMINAL UNLESS NOTED OTHERWISE.
8. DO NOT SCALE DRAWINGS; DIMENSIONS SHALL GOVERN.
9. INTERIOR PARTITION TYPE INFORMATION IS LOCATED ON SHEET AE511.
10. EXTERIOR WALL CONSTRUCTION SHOWN ON WALL SECTIONS.
11. LOCATE DOOR FRAMES 4” CLEAR FROM ADJACENT PERPENDICULAR WALLS
UNLESS NOTED OTHERWISE.
12. SEE GI003 FOR MOUNTING HEIGHTS OF PLUMBING FIXTURES AND ACCESSORIES.
B
A
AC01
AC02
F6
AE511
CEILING PLAN NOTES
1. MECHANICAL AND ELECTRICAL INFORMATION SHOWN IS INTENDED ONLY TO
COMMUNICATE DESIGN INTENT. REFER TO MECHANICAL AND ELECTRICAL
DRAWINGS FOR DETAILED INFORMATION. NOTIFY CONTRACTING OFFICER OF ANY
DISCREPANCIES NOTED PRIOR TO COMMENCEMENT OF WORK.
2. COORDINATE ALL CEILING MOUNTED EQUIPMENT SUPPORTS, DEVICE LOCATIONS,
CLEARANCES, ETC. WITH EQUIPMENT INSTALLERS AND SUPPLIERS PRIOR TO
INSTALLATION.
3. ACOUSTICAL PANEL CEILING GRIDS OR PANELS SHALL BE CENTERED IN ROOMS
UNLESS OTHERWISE NOTED OR DIMENSIONED.
4. ALL CEILING MOUNTED ITEMS (LIGHT FIXTURES, SPRINKLER HEADS, SPEAKERS,
ETC.) SHALL BE CENTERED IN ACOUSTICAL CEILING PANELS OR GYPSUM BOARD
SOFFITS UNLESS OTHERWISE NOTED OR DIMENSIONED.
5. SPACE LIGHT FIXTURES EVENLY IN ROOMS, BAYS, SPACES, ETC. AND CENTER
BETWEEN EXPOSED STRUCTURAL ELEMENTS WHERE APPROPRIATE.
6. DIMENSIONS TO CEILING-INSTALLED ITEMS ARE TO CENTERLINE OF FIXTURE OR
EQUIPMENT UNLESS NOTED OTHERWISE.
7. LOCATE CONTROL JOINTS IN GYPSUM BOARD CEILINGS, SOFFITS, BULKHEADS, AND
FASCIAS AS INDICATED ON DRAWINGS OR AS SPECIFIED AND TO ALIGN WITH THOSE
IN WALLS BELOW. VERIFY PROPOSED LAYOUT WITH CONTRACTING OFFICER PRIOR
TO INSTALLATION.
8. PAINT ALL CONDUITS, DUCTWORK, SUPPORTS, HANGERS, ETC. THAT WILL REMAIN
EXPOSED TO VIEW. MATCH COLOR INDICATED FOR STRUCTURE (PNT-1) UNLESS
NOTED OTHERWISE.
CEILING PLAN LEGEND
LIGHT FIXTURES
EXIT LIGHT
B
A
STRUCTURAL SLOPE
AR03
AR05
STRUCTURAL SLOPE
F2
AE311
F5
AE311
A4
AE511
AR06
C4
AE511
FRAME TYPE
2"
SCHEDULE
SEE DOOR 2"
2"
DOOR TYPES
FLUSH
SCHEDULE
SEE DOOR
F
IN CONCRETE
IN CMU/CONCRETE
HEAD
JAMB
HEAD
JAMB
SILL
OHS
INSULATED
INSULATED
C4
AE511
F4
AE511
E4
AE511
C1
AE511
F1
AE511
S E
E D
O O
R S
C H
E D
U
LE
S E
E D
O O
R S
C H
E D
U
LE
IN CMU
HEAD
JAMB
F8
AE511
F9
AE511
CONCRETE OR BITUMINOUS
DRIVEWAY
16"Ø CONCRETE FOOTING
6"Ø SCHEDULE 40 STEEL PIPE -
GALVANIZED - FILL PIPE WITH
CONCRETE
4' -0
4'
-0
EXTERIOR
CONCRETE SURROUND - SLOPE
AWAY FROM GUARDPOST AT
1/4"/FOOT
BACKER ROD AND SEALANT
AROUND ENTIRE FOOTING
3/16" GALVANIZED STEEL CAP
WELDED WATER TIGHT
8' -0
INSTALL REFLECTIVE STRIPE AT
TOP OF BOLLARD AFTER CAP IS
INSTALLED
6"Ø SCHEDULE 40
GALVANIZED PIPE
4' -0
3/16" GALVANIZED STEEL
CAP SHOP WELD WATER
TIGHT
STEEL SPOOL
1/4"
INTERIOR
MARCH 19, 2019
Location
Project Number
Drawing Number
Project Title
Issue Date Checked Drawn
HENNEPIN COUNTY, MINNESOTA
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FORT SNELLING NATIONAL CEMETERY
MAINTENANCE BUILDING 3001 &
MATERIAL HANDLING FACILITY
894CM3038BID DOCUMENTS
LEO A DALY
(612) 338-8741
ECS MID-ATLANTIC, LLC
(847) 279-0366
O'CONNOR CONSTRUCTION
MANAGEMENT, INC.
(202) 299-0530
CULTURAL RESOURCE ANALYSTS, INC.
(859) 252-4737
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
GORDON - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
GORDON
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:_____________________________
Typed or Printed Name:__________________
Date:__________ License Number:_________
John R. Guerber
03/19/19 52755
FLOOR, CEILING & ROOF PLANS
AE111
JMH JRG 83
SCALE: 1/8" = 1'-0"
F5
FLOOR PLAN
SCALE: 1/8" = 1'-0"
F1
CEILING PLAN
KEYNOTE LEGEND
KEY DESCRIPTION
AC01 OPEN TO STRUCTURE
AC02 MECHANICAL EQUIPMENT, SEE MECH
AF01 6" DIA GUARD POST
AF02 CONCRETE STOOP, SEE STRUCTURAL
AF03 PRECAST CONCRETE SPLASH BLOCK
AR03 PREFINISHED METAL FASCIA
AR05 MECHANICAL EQUIPMENT, SEE MECH.
AR06 TAPERED INSULATION CRICKET, 1/2" PER FOOT SLOPE
DOOR SCHEDULE
DOOR NO.
DOOR
HDWE SET
DOOR FRAME
LABEL HOURWIDTH HEIGHT TYPE MAT'L FIN. TYPE MAT'L FIN.
106A 16'-0" 16'-0" 33 OHS STL MFR STD -- -- MFR STD --
106B 16'-0" 16'-0" 33 OHS STL MFR STD -- -- MFR STD --
107A 3'-0" 7'-0" 14 F HM P-2 1 HM P-2 --
107B 3'-0" 7'-0" 14 F HM P-2 1 HM P-2 --
108 3'-0" 7'-10" 7 F HM P-2 1 HM P-2 --
SCALE: 1/8" = 1'-0"
C1
ROOF PLAN
NN
N
SCALE: 1/2" = 1'-0"
B4
DETAIL - GUARDPOST
LEVEL 1
100'-0"
ROOF
124'-8"
BA
'-8
AE03
AE02
AE07
AE01
F2
AE311
AE06
LEVEL 1
100'-0"
ROOF
124'-8"
'-8
AE01
AE05
AE07F5
AE311
AE06
LEVEL 1
100'-0"
ROOF
124'-8"
1 2
AE01
AE07 F5
AE311
AE06
LEVEL 1
100'-0"
ROOF
124'-8"
B A
'-8
16'-0" 2'-0" 3'-4" 16'-4"
AE02
AE03
AE05
AE07
AE01
F2
AE311
AE06
MARCH 19, 2019
Location
Project Number
Drawing Number
Project Title
Issue Date Checked Drawn
HENNEPIN COUNTY, MINNESOTA
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FORT SNELLING NATIONAL CEMETERY
MAINTENANCE BUILDING 3001 &
MATERIAL HANDLING FACILITY
894CM3038BID DOCUMENTS
LEO A DALY
(612) 338-8741
ECS MID-ATLANTIC, LLC
(847) 279-0366
O'CONNOR CONSTRUCTION
MANAGEMENT, INC.
(202) 299-0530
CULTURAL RESOURCE ANALYSTS, INC.
(859) 252-4737
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
GORDON - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
GORDON
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:_____________________________
Typed or Printed Name:__________________
Date:__________ License Number:_________
John R. Guerber
03/19/19 52755
EXTERIOR ELEVATIONS
AE211
JMH JRG 84
SCALE: 1/8" = 1'-0"
B1
SOUTH ELEVATION
SCALE: 1/8" = 1'-0"
B5
EAST ELEVATION
SCALE: 1/8" = 1'-0"
D1
WEST ELEVATION
SCALE: 1/8" = 1'-0"
D5
NORTH ELEVATION
KEYNOTE LEGEND
KEY DESCRIPTION
AE01 1 1/2" METAL PANEL, MP-2
AE02 OVERHEAD DOOR 16'-0" X 16'-0"
AE03 EXTERIOR DOOR 3'-0" X 7'-0"
AE05 PREFINISHED ALUMINUM DOWNSPOUT
AE06 6" DIA BOLLARD
AE07 MECHANICAL EQUIPMENT
LEVEL 1
100'-0"
ROOF
124'-8"
1 2
8" CONCRETE STEM WALL
8' -0
EXTERIOR WALL ASSEMBLY 5
EXTERIOR WALL ASSEMBLY 7
ROOF ASSEMBLY 1
FLOOR ASSEMBLY 2
OVERHEAD DOOR
LEVEL 1
100'-0"
ROOF
124'-8"
BA
8' -0
EXTERIOR WALL ASSEMBLY 5
EXTERIOR WALL ASSEMBLY 6
EXTERIOR WALL ASSEMBLY 7
ROOF ASSEMBLY 1
FLOOR ASSEMBLY 2
LEVEL 1
100'-0"
ROOF
124'-8"
EXTERIOR WALL ASSEMBLY 5
EXTERIOR WALL ASSEMBLY 7
ROOF ASSEMBLY 1
FLOOR ASSEMBLY 2
116'-0"
AE511
C1
AE511
B6
F1
AE511
GUARDPOST, TYP
EXTERIOR ASSEMBLY TYPES
EXTERIOR WALL ASSEMBLY 5
• 1 1/2" METAL PANEL PER 07 40 00
• 2 1/2" RIGID INSULAITON (R-13.3 MIN) PER 07 21 13
• VAPOR RETARDER PER 07 21 13
• 12" CMU PER 04 20 00, SEE STRUCTURAL
EXTERIOR WALL ASSEMBLY 6
• 1 1/2" METAL PANEL PER 07 40 00
• 2 1/2" RIGID INSULATION (R-13.3 MIN) PER 07 21 13
• VAPOR RETARDER PER 07 21 13
• 12" CAST-IN-PLACE CONCRETE PER 03 30 53, SEE STRUCTURAL
EXTERIOR WALL ASSEMBLY 7
• 12" CAST-IN-PLACE CONCRETE PER 03 30 53, SEE STRUCTURAL
• BITUMINOUS DAMPROOFING PER 07 11 13
ROOF ASSEMBLY 1
• EPDM MEMBRANE PER 07 53 23
• COVER BOARD PER 07 22 00
• 6" RIGID INSULATION (R-30 MIN) PER 07 22 00
FLOOR ASSEMBLY 2
• CONCRETE SLAB PER 03 30 53, SEE STRUCTURAL
• 4" RIGID INSULATION (R-20 MIN)
• VAPOR BARRIER PER 03 30 53
LEVEL 1
100'-0"
ROOF
124'-8"
B
163 SF
SAND BIN
EXTERIOR WALL ASSEMBLY 5
EXTEROR WALL ASSEMBLY 6
EXTERIOR WALL ASSEMBLY 7
FLOOR ASSEMBLY 2
ROOF ASSEMBLY 1
PREFINISHED METAL GUTTER
TOP OF STEM WALL
108'-0"
AE511
B8
AE511
D8
MARCH 19, 2019
Location
Project Number
Drawing Number
Project Title
Issue Date Checked Drawn
HENNEPIN COUNTY, MINNESOTA
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FORT SNELLING NATIONAL CEMETERY
MAINTENANCE BUILDING 3001 &
MATERIAL HANDLING FACILITY
894CM3038BID DOCUMENTS
LEO A DALY
(612) 338-8741
ECS MID-ATLANTIC, LLC
(847) 279-0366
O'CONNOR CONSTRUCTION
MANAGEMENT, INC.
(202) 299-0530
CULTURAL RESOURCE ANALYSTS, INC.
(859) 252-4737
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
GORDON - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
GORDON
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:_____________________________
Typed or Printed Name:__________________
Date:__________ License Number:_________
John R. Guerber
03/19/19 52755
BUILDING & WALL SECTIONS
AE311
JMH JRG 85
SCALE: 1/8" = 1'-0"
D7
BUILDING SECTION - NORTH/SOUTH
SCALE: 1/8" = 1'-0"
F7
BUILDING SECTION - EAST/WEST
SCALE: 1/2" = 1'-0"
F2
WALL SECTION AT OVERHEAD DOOR
SCALE: 1/2" = 1'-0"
F5
WALL SECTION AT STEM WALL
ROOF ASSEMBLY 1
16 GAUGE GALVANIZED PANEL
CAP FASTENED W/ SCREWS 1'-0"
O.C.
4" WIDE PREFINISHED STRAP
ANCHORS. 5'-0" OC WITH
STRAPS WITHIN 12" OF TOP
AND BOTTOM
3/16"X1-1/2" GALV. BRACKET AT
36" OC MIN.-PREFINISHED TO
MATCH GUTTER
PREFINISHED CONTINUOUS
GUTTER.(6"W X 6"D) SLOPE TO
DOWNSPOUTS 1/8" PER FOOT
MINIMUM. PROFILE FRONT TO BE 1"
LOWER THAN BACK PROFILE
PREFINISHED METAL DOWNSPOUT -
CLOSED FACE (5-1/2" WIDE x 5-1/2"
DEEP)
FAB LOCK ANCHOR TO
METAL WALL PANEL
STAGGER LOCATION OF GUTTER
STRAPS AND BRACKETS
3/16" X 1" GALV. STRAPS
PREFINISHED TO MATCH GUTTER,
3'-0" O.C.
PRE-DRILL GUTTER FOR HIGH
STRENGTH RIVET - DO NOT
PUNCTURE ROOF MEMBRANE
FOR ADDITIONAL INFOMATION, SEE
B6
AE511
FLOOR
ASSEMBLY 2
SELF ADHERING MEMBRANE
FLASHING OVER METAL FLASHING
EXTERIOR WALL ASSEMBLY 6
PREFINISHED METAL FLASHING
BY METAL PANEL PROVIDER
VAPOR RETARDER
EXTERIOR WALL ASSEMBLY 7
SEE CIVIL FOR GRADING OR PAVING
DOOR SEAL
SECTIONAL DOOR ASSEMBLY
BOND BEAM - SEE
STRUCTURAL NOTES
SELF ADHERING MEMBRANE
FLASHING OVER METAL FLASHING
PREFINISHED METAL FLASHING
BY METAL PANEL PROVIDER
VAPOR RETARDER
EXTERIOR WALL ASSEMBLY 5
SEALANT EACH SIDE
HOLLOW METAL DOOR AND
FRAME, GROUT FRAME SOLID
BOND BEAM - SEE STRUCTURAL NOTES
2"
PREFINISHED METAL DRIP EDGE
AT EXTERIOR DOORS
SELF ADHERING MEMBRANE
FLASHING OVER METAL FLASHING
PREFINISHED METAL FLASHING
BY METAL PANEL PROVIDER
VAPOR RETARDER
1"
T.O. WALL
108'-0"
HOLLOW METAL FRAME WITH THREE
ANCHORS PER JAMB GROUT FRAME
SOLID
CONTINUOUS SEALANT-
BOTH SIDES
CONC. WALL TO 8'-0"H AND CMU
ABOVE, GROUT CORES SOLID AT
BEARING - SEE STRUCTURAL
NOTES FOR REINFORCING
PREFINISHED METAL CLOSURE
BY METAL PANEL PROVIDER
CONT. SEALANT TAPE
DOOR TRACK & MOUNTING
ANGLE
DOOR SEAL
SECTIONAL DOOR
6"DIA GUARDPOST, TYP
2 8
PREFINISHED METAL CLOSURE
BY METAL PANEL PROVIDER
CONT. SEALANT TAPE
1' -0
1'
-0
CONC. WALL TO 8'-0"H AND CMU
ABOVE, GROUT CORES SOLID AT
BEARING - SEE STRUCTURAL
NOTES FOR REINFORCING
DOOR AS SCHEDULED
ALUMINUM THRESHOLD SET IN BED
OF MASTIC, 1/2" MAX HEIGHT
WALL BEYOND
CONC STOOP, SEE STRUCTURAL
COMPRESSIBLE FILLER
FLOOR
ASSEMBLY 1
CONC SLAB &
FOUNDATION
CONT. SEALANT TAPE
E Q
EQ.
CONC. WALL BELOW
EXTERIOR WALL ASSEMBLY 5
PREFINISHED METAL FLASHING
BELOW
VAPOR RETARDER
CONC. WALL TO 8'-0"H AND CMU
ABOVE, GROUT CORES SOLID AT
BEARING - SEE STRUCTURAL
NOTES FOR REINFORCING
METAL DECK - FIELD VERIFY
CONNECTION TO CMU AND
TERMINATION POINT IN RELATION
TO THE EXTERIOR FACE OF CMU
STEEL BAR JOIST - SEE STRUCTURAL
8" CMU WALL
SEALANT
1/2" DIA ANCHOR BOLTS AT 4'-0"O.C.
SET BACK MIN 2 1/2" FROM EXTERIOR
FACE OF CMU. WOOD NAILERS TO BE
6" WIDE X TOTAL OF THICKNESS OF
ROOF INSULATION
FILL VOID MIN. 1" WIDE OR LARGER W/
FOAM-IN-PLACE INSULATION TO DECKINGROOF ASSEMBLY 1
22GA GALV. CONT. CLOSURE
FASTENED AT 6" OC
24GA PREFINISHED METAL GRAVEL
STOP FASTENED AT 6" OC
EXTEND FIELD MEMBRANE BELOW
WOOD NAILERS
LAP SEALANT
EPDM FLASHING ROOF MEMBRANE
METAL PANEL MP-2 ON
2 1/2" HORIZONTAL Z FURRING
AT 1'-4" OC W/ 2 1/2" RIGID
INSULATION
VAPOR RETARDER
8"
EPDM MEMBRANE
TWO PIECE SLIP JOINT COVER
STAINLESS STEEL CLAMP
BAND
PREFABRICATED PIPE BOOT
FILL WITH SPRAY IN PLACE
FOAM
PLUMBING VENT STACK
6" RIGID INSULATION (R-30 MIN)
HOT AIR WELD
SEALANT
PROTECTION BOARD
FILL VOID MIN. 1" WIDE OR LARGER
W/ FOAM-IN-PLACE INSULATION TO
DECKING
EPDM MEMBRANE
TAPERED RIGID INSULATION SADDLE WITH 1/2"
PER 1'-0" SLOPE, INSTALL ON HIGH SIDE OF
CURB ONLY
60 MIL. FULLY ADHERED EPDM
FLASHING ROOF MEMBRANE
24GA PREFINISHED METAL COUNTER
FLASHING FASTEN WITH HIGH-DOMED
CAPPED (NO. 10) 1 1/2" GALVANIZED
SCREW AND NEOPRENE WASHER
FOAM NEOPRENE ISOLATOR PAD
6" RIGID INSULATION (R-30 MIN)
ROOF EQUIPMENT
HOT AIR WELD
S C
H E
D U
LE
S
S E
E M
E C
H
CONTINUOUS DECAY-RESISTANT 2X
PRESERVATIVE TREATMENT WOOD NAILER
FASTENED WITH (2) ROWS OF
NO. 10 X 3" LONG GALVANIZED SCREW AT 2'-0"
OC WITH 5/8" OD GALVANIZED STEEL WASHER
FULLY ADHERE FIELD MEMBRANE
3" UP VERTICAL SURFACE
PROTECTION BOARD
3" 2" SEAM PLATES 12" O.C. BOTTOM OF PLATES
TO BE WITHIN 1/2" OF ROOF SURFACE
SEALANT
STAINLESS STEEL CLAMPING BAND
PREFABRICATED PIPE BOOT
FILL BOOT WITH SPRAY IN PLACE
FOAM OVER PERISHABLE AREAS
HOT AIR WELD
EPDM MEMBRANE
CONDUIT, GAS PIPE OR ROOF
HYDRANT.
STEEL PIPE SUPPORTS AT SIM
6" RIGID INSULATION (R-30 MIN)
FILL VOID MIN. 1" WIDE OR LARGER
W/ FOAM-IN-PLACE INSULATION TO
DECKING
PROTECTION BOARD
8"
CMU WALL, SEE FLOOR PLAN FOR
TYPE
HM FRAME, GROUT SOLID
DOOR AS SCHEDULED
BACKER ROD & SEALANT BOTH SIDES
BACKER ROD & SEALANT BOTH
SIDES
DOOR AS SCHEDULED
CMU WALL
SHIM
HM FRAME WITH THREE ANCHORS
PER FRAME GROUTED SOLID
BULLNOSE CORNER
1/2" PLYWOOD
PREFINISHED METAL TRIM
CMU, SEE FLOOR PLAN
6" METAL JOISTS AT 16" OC
NOTE: STORAGE OF MATERIALS
ON TOP OF MECH ROOM IS
PROHIBITED
TOP OF CMU
10'-0" AFF
MARCH 19, 2019
Location
Project Number
Drawing Number
Project Title
Issue Date Checked Drawn
HENNEPIN COUNTY, MINNESOTA
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FORT SNELLING NATIONAL CEMETERY
MAINTENANCE BUILDING 3001 &
MATERIAL HANDLING FACILITY
894CM3038BID DOCUMENTS
LEO A DALY
(612) 338-8741
ECS MID-ATLANTIC, LLC
(847) 279-0366
O'CONNOR CONSTRUCTION
MANAGEMENT, INC.
(202) 299-0530
CULTURAL RESOURCE ANALYSTS, INC.
(859) 252-4737
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
GORDON - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
GORDON
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:_____________________________
Typed or Printed Name:__________________
Date:__________ License Number:_________
John R. Guerber
03/19/19 52755
DETAILS
AE511
JMH YSK 86
SCALE: 3" = 1'-0"
B8
ROOF DETAIL - ROOF EDGE AT GUTTER
SCALE: 3" = 1'-0"
D8
SECTION - GRADE
SCALE: 3" = 1'-0"
C1
DOOR DETAIL - OVERHEAD DOOR HEAD
SCALE: 3" = 1'-0"
C4
DOOR DETAIL - HM DOOR HEAD
SCALE: 3" = 1'-0"
E4
DOOR DETAIL - HM DOOR JAMB
SCALE: 3" = 1'-0"
F1
DOOR DETAIL - OVERHEAD DOOR JAMB
SCALE: 3" = 1'-0"
F4
DOOR DETAIL - HM DOOR SILL
SCALE: 3" = 1'-0"
D6
PLAN - CORNER
SCALE: 3" = 1'-0"
B6
ROOF DETAIL - CMU ROOF EDGE
SCALE: 1 1/2" = 1'-0"
A1
ROOF DETAIL AT VENT STACK PENETRATION
SCALE: 1 1/2" = 1'-0"
A4
ROOF DETAIL - EQUIPMENT SUPPORT
SCALE: 1 1/2" = 1'-0"
A3
ROOF DETAIL - SMALL DIAMETER PENETRATIONS
SCALE: 3" = 1'-0"
F8
SECTION - HM DOOR HEAD AT CMU
SCALE: 3" = 1'-0"
F9
PLAN - HM DOOR JAMB AT CMU
SCALE: 3" = 1'-0"
F6
SECTION - LID AT MECH 108
B
A
IRH-1
IRH-1
HB-1
CONNECT TO WATER
MAIN, SEE CIVIL PLANS
CONNECT TO NAT.
GAS MAIN SEE CIVIL
PLANS
GAS PIPE UP THROUGH
ROOF
GAS PIPE ROUTED ON SIDE OF
BUILDING UP TO ROOF. SEE
ROOF PLAN FOR CONTINUATION
GAS METER
683 CFH
HYD-1
HYD-1
3/4"
3/4"
3/4"
HB-1
3/4"
1" WATER METER
1" G
1 1/2" G
1" G
FD-1
FD-1
FD-1
4" SS
4" SS
4" SS
4" SS
3" SS
FD-2
4" SS
3/4" CW
1" CW
SANITARY SEWER PIPING
BELOW SLAB-TYPICAL
SANITARY SEWER PIPING
BELOW SLAB-TYPICAL
4" SS
4" SS
INV. EL. 42" BELOW GRADE
275 GALLON SAND/OIL SEPARATOR
STRIEM MODEL FLI 275
4" SSB-1
2" G
3/4"G -CONNECT
TO B-1
3/4"G UP
THROUGH ROOF
B
A
1-1/2" G
DOWN TO
IRH-1
ERV-1
GAS PIPING DN ON
OUTSIDE OF BUILDING
TO GAS METER- SEE
PLUMBING FLOOR PLAN
2" G 1 1/2" G
2" G
2" G
3/4" G
3/4"G DN TO RADIANT HEAT
BOILER B-1
MARCH 19, 2019
Location
Project Number
Drawing Number
Project Title
Issue Date Checked Drawn
HENNEPIN COUNTY, MINNESOTA
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FORT SNELLING NATIONAL CEMETERY
MAINTENANCE BUILDING 3001 &
MATERIAL HANDLING FACILITY
894CM3038BID DOCUMENTS
LEO A DALY
(612) 338-8741
ECS MID-ATLANTIC, LLC
(847) 279-0366
O'CONNOR CONSTRUCTION
MANAGEMENT, INC.
(202) 299-0530
CULTURAL RESOURCE ANALYSTS, INC.
(859) 252-4737
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
GORDON - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
GORDON
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456 03/19/19
I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the state of Minnesota.
Signature:_____________________________
Typed or Printed Name:__________________
Date:__________ License Number:_________
Chad M. Eslinger
48710
PLUMBING FLOOR PLAN
PL111
LLK GJH 87
SCALE: 1/8" = 1'-0"
F6
PLUMBING PLAN LEVEL 1 OVERALL
DOMESTIC FIXTURE SCHEDULE
ID DESCRIPTION FINISH
TRIM FLOW FIXTURE COLD
WATER
ROUGH-IN
PIPE SIZE SPECIFICATION REMARKSMANUFACTURER MODEL TYPE WATER FLOW
COLD
WATER
TEMP.
MAX. MIXED
WATER
TEMP.
HB-1 HOSE BIBB CHICAGO FAUCET
CO
952-CP MANUAL 3 GPM 40 40 1/2” INTERIOR HOSE BIBB WITH VACUUM BREAKER, 3/4" HOSE THREAD OUTLET, LOCK SHIELD CAP, AND REMOVABLE
"TEE" HANDLE. PROVIDE SHUTOFF VALVE IN COLD WATER SUPPLY AHEAD OF HOSE BIBB.
HYD-1 EXTERIOR WALL HYDRANT WOODFORD 67 MANUAL 3 GPM 40 40 3/4” NON-FREEZE TYPE WALL HYDRANT, WITH DOUBLE CHECK BACKFLOW PREVENTER, VALVE ON THE INSIDE OF THE WALL, SPOUT WITH BACKFLOW PREVENTER, AND LOOSE KEY SOCKET ON THE OUTSIDE OF THE WALL.
MAKE ARRANGEMENTS WITH THE GENERAL CONTRACTOR TO PROVIDE THE NECESSARY RECESS IN THE WALL.
WHERE A RISER TO A WALL HYDRANT OCCURS IN AN OUTSIDE WALL THE CONTRACTOR SHALL INSULATE THE CHASE WITH 2” STYROFOAM INSULATION ON ALL SIDES OF THE CHASE, EXCEPT THE INSIDE WALL OF THE
CHASE. PROVIDE SHUTOFF VALVE IN ACCESSIBLE LOCATION.
SCALE: 1/8" = 1'-0"
E2
PLUMBING PLAN ROOF
N N
FLOOR DRAIN SCHEDULE
TAG DESCRIPTION MANUFACTURER MODEL QTY
MATERIAL DESCRIPTION PRIMER
CONNECTION
WASTE VENT PRIMER
SPECIFICATION REMARKSDRAIN BODY STRAINER PIPE SIZE PIPE SIZE PIPE SIZE
FD-1 HEAVY DUTY FLOOR
DRAIN
JOSAM 37810 3 EPOXY COATED
CAST IRON
DUCTILE IRON No 4” 2” --- ON-GRADE CAST IRON FLOOR DRAIN WITH ANCHOR FLANGE, WEEPHOLES, HEAVY DUTY SQUARE DUCTILE
IRON STRAINER, AND NO HUB OUTLET.
FD-2 FLOOR DRAIN JOSAM 3000-A 1 EPOXY COATED
CAST IRON
NICKEL BRONZE No 3” 2” --- EPOXY COATED CAST IRON FLOOR DRAIN WITH ANCHOR FLANGE, REVERSIBLE CLAMPING COLLAR WITH PRIMARY & SECONDARY WEEPHOLES, ADJUSTABLE ROUND HEEL PROOF NICKEL BRONZE STRAINER, AND NO
HUB OUTLET.
gjhaik Image
M
METER TO HAVE BOTH: DIRECT REGISTER READ (IN GALLONS)
AND REMOTE READABLITY (VIA PULSE INTIATOR)
ABOVE GROUND METER ASSEMBLY
AFFIXED TO BUILDING
NOTES:
1. PROVIDE A "DRESSER-TYPE" COUPLING ON METER ASSEMBLY
INSTALLATIONS IN VAULTS TO ALLOW FOR EASY REMOVAL OF FLANGED
COMPONENTS.2. METERING ASSEMBLY TO BE PROPERLY INSTALLED AND ADEQUATELY
SUPPORTED TO ALLOW FOR EASY MAINTENANCE, REPAIR AND REPLACEMENT.
PRESSURE REDUCING VALVE AND GATE VALVE
METER
PLATE/PIPE SUPPORT
METER ASSEMBLY MUST BE
PROPERLY SUPPORTED
AND LINE AFFIXED TO BLDG.
GATE VALVES
FINISHED WALL
WALL BOX FLANGE
X"
WALL CLAMP (IF USED)
INSIDE (BACK) OF WALL
3/4" INLET
CONNECTION
NOTE: LINE SIZES AS CALLED FOR ON SITE PLAN
(POLY)SERVICE SHUT-OFF VALVE
W/2" SQ. OPERATING NUT
4" CONCRETE PAD
FINISHED
GRADE
CAST IRON EXTENSION TYPE SERVICE BOX
TO BUILDING
SUPPLY
GAS MAIN, 10-45 PSIG
GAS PRESSURE REGULATOR
TEE W/BUSHING AND 3/8" PLUG
HOT TAP VALVE
SWING JOINT OUTLET
BUTT WELDED SERVICE TEE
PLUGGED TEE W/BUSHING AND 3/8" PLUG
GAS COCK(TYP.)
ANNODELESS RISER
INSULATING UNION
DIRT POCKET
GAS PIPE
UNION
LUBRICATED PLUG COCK
AS APPROVED BY LOCAL
CODE AUTHORITY
ROOFTOP EQUIPMENT
APPLIANCE REGULATORS
ROOF
G
PIPE CLAMP W/ VIBRA STRIP PIPE CUSHION
NOTES:
1. PAINT ALL METAL SURFACES WITH GLOSS BLACK RUST RESISTANT ENAMEL.
2. COORDINATE LOCATIONS OF PIPE SUPPORTS WITH ROOFING CONTRACTOR.
ADDITIONAL PAD
BY OTHERS
ROOF
PIPE PIER PIPE BLOCK
PIPE
FIRESTOPPING MATERIAL
IN ACCORDANCE WITH UL
723 OR 1479
SEALANT-JOINT 1/4"
MIN. WIDE BY 3/8" DEEP
PIPE
PIPE SLEEVE
ESCUTCHEON (TYPICAL
FOR FINISHED INTERIOR WALLS)
STANDARD CLEVIS PIPE HANGER
INSULATION PROTECTION SHIELD.
ROD, STEEL, GALVANIZED OR
ELECTRO-PLATED
HEX. NUTS WITH FLAT WASHERS,
GALVANIZED OR ELECTRO-PLATED
CONCRETE
EXPANSION
BOLT CASING
INSULATION WITH HIGH DENSITY
INSERT AT SUPPORT
MARCH 19, 2019
Location
Project Number
Drawing Number
Project Title
Issue Date Checked Drawn
HENNEPIN COUNTY, MINNESOTA
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FORT SNELLING NATIONAL CEMETERY
MAINTENANCE BUILDING 3001 &
MATERIAL HANDLING FACILITY
894CM3038BID DOCUMENTS
LEO A DALY
(612) 338-8741
ECS MID-ATLANTIC, LLC
(847) 279-0366
O'CONNOR CONSTRUCTION
MANAGEMENT, INC.
(202) 299-0530
CULTURAL RESOURCE ANALYSTS, INC.
(859) 252-4737
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
GORDON - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
GORDON
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456 03/19/19
I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the state of Minnesota.
Signature:_____________________________
Typed or Printed Name:__________________
Date:__________ License Number:_________
Chad M. Eslinger
48710
PLUMBING DETAILS
PL511
LLK GJH 88
SCALE:1 : 1
B1
WATER METER DETAIL
SCALE:1 : 1
B3
FREEZEPROOF WALL HYDRANT DETAIL
SCALE:1 : 1
B5
TYPICAL GAS SERVICE CONNECTION DETAIL
SCALE:1 : 1
B8
GAS CONNECTION TO ROOFTOP EQUIPMENT DETAIL
SCALE:1 : 1
C1
GAS PIPE SUPPORT ON ROOF DETAIL
SCALE:1 : 1
C3
ABOVE GRADE PIPING RATED WALL PENETRATION DETAIL
SCALE:1 : 1
D5
CEILING HUNG PIPE SUPPORT FOR INSUL. PIPE DETAIL
B
A
1534 SF
DRIVE LANE
1061 SF
SCREENING AREA
163 SF
MULCH BIN
163 SF
SOIL BIN
163 SF
CLASS 5 BIN
163 SF
SAND BIN
155 SF
SALT BIN
G-1 (TYP.)
14ø OA
14ø OA
UP39x32 OA
50x20 EA UP
10ø OA
16ø OA
16ø OA
10ø OA 16ø OA
16ø OA
14ø OA
10ø OA
14ø OA
10ø OA
IRH-1
IRH-1
4ø
4ø
20x20
20x20
4" TYPE B FLUE UP
THROUGH ROOF
4" TYPE B FLUE UP
THROUGH ROOF
B-1
P-1
EUH-1
MANIFOLD TO AND
FROM RADIANT
HEATING SYSTEM
1 1/4" HWS
AS-1
MECH
IN FLOOR RADIANT HEATING AREA,
SEE RADIANT HEATING SCHEDULE
ABOVE.
ET-1 T
1 1/4" HWR
BOILER INTAKE
AND FLUE
ERU-1
CONTROL
PANEL
B-1
B
A
ERU-1
4" TYPE "B" FLUE
TERMINATE 3'-0"
ABOVE ROOF
4" TYPE "B" FLUE
TERMINATE 3'-0"
ABOVE ROOF
MARCH 19, 2019
Location
Project Number
Drawing Number
Project Title
Issue Date Checked Drawn
HENNEPIN COUNTY, MINNESOTA
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FORT SNELLING NATIONAL CEMETERY
MAINTENANCE BUILDING 3001 &
MATERIAL HANDLING FACILITY
894CM3038BID DOCUMENTS
LEO A DALY
(612) 338-8741
ECS MID-ATLANTIC, LLC
(847) 279-0366
O'CONNOR CONSTRUCTION
MANAGEMENT, INC.
(202) 299-0530
CULTURAL RESOURCE ANALYSTS, INC.
(859) 252-4737
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
GORDON - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
GORDON
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456 03/19/19
I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the state of Minnesota.
Signature:_____________________________
Typed or Printed Name:__________________
Date:__________ License Number:_________
Chad M. Eslinger
48710
MECHANICAL FLOOR PLAN
MH111
LLK GJH 89
SCALE: 1/8" = 1'-0"
F6
HVAC FLOOR
SCALE: 1/8" = 1'-0"
F2
HVAC ROOF PLAN
GRILLES, REGISTERS AND DIFFUSERS SCHEDULE
ID DESCRIPTION MANUFACTURER MODEL QTY SYSTEM
FACE
SIZE
NECK DIFFUSER
TOTAL
LENGTH
BLADE DESIGN INSTALLATION
SPECIFICATION NOTESSIZE WIDTH HEIGHT THICKNESS SPACING
DEFLECTION ANGLE
ORIENTATION BORDER TYPESINGLE DOUBLE
G-1 LOUVERED DOUBLE DEFLECTION
GRILLE
TITUS 300FL 13 --- 20 6 0" 1/8” 3/4" 0.00° 0.00° DOUBLE-LONG TYPE 1 (SURFACE)
DEDICATED OUTDOOR AIR SYSTEM SUMMARY SCHEDULE - GAS
TAG MANUFACTURER MODEL NO. TYPE
SUPPLY AIR
EXHAUST
AIRFLOW
SUPPLY FAN RETURN FAN
SUMMER DESIGN ENERGY
RECOVERY
WINTER DESIGN ENERGY
RECOVERY
GAS-FIRED HEAT
EXCHANGER
UNIT
WEIGHT FLA MCA MOCP VOLT PH REMARKSFLOW
OA
MOTOR MOTOR
COOLING CAP CAP FUEL INPUT (BTU/H)QTY POWER QTY POWER
ERU-1 DAIKIN RN0183000003CB HORIZONTAL 5455 100 5455 1 5.0 hp 1 5.0 hp 134,360 306,352 342,300 2491.00 lbf
15 A 17 A 20 A 480 V 3
INFRARED HEATER SCHEDULE
MARK SERVES TYPE
GAS BURNER VACUUM EXHAUSTER
MANUFACTURER MODEL NOTES
HEATING
CAPACITY(MBH) GAS INPUT (CFH)
MINIMUM PRESSURE
(IN W.C.) MAXIMUM PRESSURE (IN W.C.) INLET OUTLET
ELECTRICAL MOTOR SPEED
(RPM) INLET
ELECTRICAL
VA VOLTAGE PHASE HZ HP VOLTAGE PHASE HZ
IRH-1 MSF LOW INTENSITY 115 115 5.5 14 1" 4" 0 0 0 0 0 4" 0.00 120 1 60 CORAYVAC CTH3-115
N N
NOTES:
1. UNIT PERIMETER ROOF CURB SHALL BE PROVIDED BY THE EQUIPMENT MANUFACTURER WITH THE SCHEDULE UNIT.
2. FOR CONTROL DIAGRAM, REFER TO DIAGRAM F1/MI701.
GAS-FIRED BOILER SCHEDULE
ID MANUFACTURER MODEL NO. ARRANGEMENT
GAS-FIRED HEAT EXCHANGER
GLYCOL
GAS-FIRED HEAT EXCHANGER
THERMAL
EFF
UNIT
WEIGHT FLA VOLT PH REMARKS
GAS BURNER WATERSIDE
INPUT CAP
FUEL
DESIGN FLOW EWT LWT PDTYPE PRESS AVAIL
B-1 RIELLO FAMILY PRO 42 IS WALL-MOUNT 94,169 87,577.2 NG 2.0 psi 30% 9 GPM 65 85 5 95% 90.00 lbf 1 A 120 V 1
CIRCULATING PUMP SCHEDULE
TAG MANUFACTURER MODEL NO. SYSTEM TYPE
PUMP MOTOR UNIT
WEIGHT MCA MOCP VOLT PH REMARKSTYPE DESIGN FLOW HEAD DRIVE TYPE BHP RPM ECM
P-1 BELL & GOSSETT ECOCIRL XL 55-45 RADIANT HEATING INLINE 9.1 GPM 20.0 FT 14 0 Yes 10.00 lbf 0 A 15 A 120 V 1
AIR SEPARATOR SCHEDULE
TAG SERVES FLOW PRESSURE DROP (IN H20) PIPE SIZE MANUFACTURER MODEL NOTES
AS-1 RADIANT HEATING 9 GPM 0.2 1 1/4" BELL & GOSSETT EASB-1-1/4 JR
ELECTRIC UNIT HEATER SCHEDULE
ID MANUFACTURER MODEL NO.
HEATING ELEMENT
UNIT
DIMENSIONS
UNIT
WEIGHT FLA VOLT PH REMARKSQTY POWER
AFF
ELEVATION
EUH-1 BERKO VFK151F 1 1.5 kW 7'-0" 22.00 lbf 13 A 120 V 1
MATERIAL HANDLING FLOOR 1 3500 0 SLAB OG/CONCRETE EMBEDDED hePEX 1/2" 12 10 310 12 20 60 20 9.1 13.7 3.1 16.8 85
ROOM HEATING ZONE # HEATED AREA UNHEATED AREA CONSTRUCTION ATTACHMENT METHOD TUBE TYPE TUBE SPACING LDR. LENGTH AVG. LOOP LENGTH
LOOPS
ROOM LOAD PER SQ FT SURFACE TEMP DESIGN TEMP DROP FLOWRATE (TOTAL) HEAD LOSS SUPPLY AND RETURN HEAD LOSS TOTAL HEAD LOSS FLUID TEMP SUPPLIED
RADIANT HEATING SCHEDULE
EXPANSION TANK SCHEDULE
TAG MANUFACTURER MODEL NO. TYPE
VOLUME (GAL) PRESSURE (PSI) UNIT DIMENSIONS UNIT
WEIGHT REMARKSACTUAL ACCEPTANCE FILL RELIEF HEIGHT DIAMETER
ET-1 BELL & GOSSETT HFT-15 FIXED DIAPHRAM 2 1 12 27 1'-0 1/2" 8" 55.70 lbf
MAIN OR BRANCH GAS PIPING
(BY OTHERS)
MAXITROL GAS PRESSURE
REGULATOR (BY OTHERS)
SHUT-OFF VALVE (INCLUDED
W/ BURNER)
END VENT PLATE FOR END BURNER ONLY
EMITTER TUBE
COMBUSTION CHAMBER ASSEMBLY
CORD AND PLUG (INCLUDED W/ BURNER)
CONDUIT TO ADDITIONAL BURNERS
AND
THEN TO CONTROL PANEL, 120V
WIRING. (BY OTHERS)
120V, 1ø RECEPTICLE (BY OTHERS)
GAS NIPPLE
12"2"
COUPLING
BURNER
4" TUBE
5/8" STAINLESS STEEL FLEX GAS CONNECTOR
(P/N 91412200, INCLUDED W/ BURNER)
CONDENSATE PIPING TO
FLOOR DRAIN
CONDENSATE TRAP
8" LONG BOOT W/ 2
CLAMPS
VACUUM PROVING
SWITCH
SUSPEND FROM
STRUCTURE
1.5 CONDUIT TO CONTROL
PANEL, 120V WIRING (BY
OTHERS)
CONDUIT TO CONTROL
PANEL/RELAY, WIRING
(LINE/LOW VOLTAGE) AS
REQUIRED
DAMPER
MOTOR
4" TAILPIPE
VACUUM PUMP
6" MIN.
9" MIN.
STACK DIAMETER.
12" MIN.
2"
FLASHING
2"
45°
FLUE
METALBESTOS
WEATHERPROOF CAP.
MIN. 3'-0" OR
AS REQUIRED
BY LOCAL
CODES.
METALBESTOS
STORM COLLAR.
1 x ANGLE SUPPORTS
ON 4 SIDES.
(4) GUSSET PLATES
ROOF CONSTRUCTION
9" MIN. OR MAX.
SNOW DEPTH
10 GA.
VENTILATED
ROOF SLEEVE
8'-0"
8'-0"
8'-0"
SPACING
MAXIMUM
SUPPORT ANGLE
HORIZONTALHANGER
ANY SIDE
MAX LENGTH
HANGER SIZES FOR RECTANGULAR DUCT
1"MIN.
DUCT
SHEET METAL STRAP 1" (25.4mm) WIDE, OF SAME METAL
GAUGE AS DUCT.
STEEL ANGLE, NOT LESS THAN 1"x 1"x 1/8" (25.4 x 25.4 x 3 mm), SIZED TO MATCH DUCT.
SHEET METAL BAND, 1" (25.4mm) WIDE OF SAME METAL
GAUGE AS DUCT.
ALL THREAD HANGER ROD WITH ACCESSORIES AS USED
FOR LIGHT PIPE HANGER.
SELF TAPPING CADMIUM PLATED HEX HEADED SHEET
METAL SCREW STRAPS TO BE TIGHT AGAINST DUCT.
KEY NOTES
30'' 1"x 18 GAGE STRAP NONE REQUIRED 10'-0"
36''
48''
60''
84''
1/4 ROUND ROD
1/4 ROUND ROD
5/16 ROUND ROD
3/8 ROUND ROD
1 1/2"x 1 1/2"x 1/8"
2"x 2"x 1/8"
2"x 2"x 1/8"
2"x 2"x 1/8"
8'-0"
ISOLATION
VALVE
CAPPED VALVE
HEAD
SUPPLY
MANIFOLD
SUPPLY PIPING TO IN-
FLOOR LOOP
RETURN
MANIFOLD
CONTROL
VALVE
ISOLATION
VALVE
RETURN PIPING FROM IN-
FLOOR LOOP
RETURN PIPING
(BY MECH CONTRACTOR)
CONCRETE SLAB
WIRE TIE
PEX TUBING
SLAB INSULATION
BASE MATERIAL
INSTALL PER
MANUFACTURER'S
STANDARD
EDGE INSULATION
STRUCTURAL
REBAR - SEE
STRUCT
TO DRAIN
HWS
FS
PRESSURE RELIEF
VALVE (60 PSI)
BOILER
SHUT-OFF VALVE
LOW WATER CUTOFF
BURNER
G
PRESSURE REGULATOR
PLUG VALVE
TO MANIFOLD
HWR
PRESSURE GAUGE
BOILER
CONTROLLER
DRAIN FOR TESTING LOW
WATER CUTOFF
FLOW SWITCH
4" CONCRETE
HOUSEKEEPING PAD
THERMOMETER
CIRCULATING
PUMP
PETE'S PLUG
PETE'S PLUG
3/4" HOSE END
DRAIN VALVE
(TYPICAL)
AIR
SEPARATOR
STRAINER
FROM MANIFOLD
MARCH 19, 2019
Location
Project Number
Drawing Number
Project Title
Issue Date Checked Drawn
HENNEPIN COUNTY, MINNESOTA
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FORT SNELLING NATIONAL CEMETERY
MAINTENANCE BUILDING 3001 &
MATERIAL HANDLING FACILITY
894CM3038BID DOCUMENTS
LEO A DALY
(612) 338-8741
ECS MID-ATLANTIC, LLC
(847) 279-0366
O'CONNOR CONSTRUCTION
MANAGEMENT, INC.
(202) 299-0530
CULTURAL RESOURCE ANALYSTS, INC.
(859) 252-4737
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
GORDON - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
GORDON
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456 03/19/19
I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the state of Minnesota.
Signature:_____________________________
Typed or Printed Name:__________________
Date:__________ License Number:_________
Chad M. Eslinger
48710
MECHANICAL DETAILS
MH511
LLK GJH 90
SCALE: NTS
B1
INFRARED HEATER BURNER CONNECTION DETAIL
SCALE: NTS
B3
INFRARED HEATER MOUNTING DETAIL
SCALE: NTS
B5
FLUE THRU ROOF DETAIL
SCALE: NTS
C7
DUCTWORK HANGING DETAIL
SCALE: 1/8" = 1'-0"
C1
IN-FLOOR MANIFOLD DETAIL
SCALE:NO SCALE
C3
CROSS SECTION OF IN-FLOOR HEAT
(SLAB ON GRADE)
SCALE: 1/8" = 1'-0"
E1
BOILER PIPING DIAGRAM
BENCHMARK #2
TOP NUT OF FIRE HYDRANT
ELEV.=820.72 (NAVD88)
EX. UNDERGROUND
ELECTRIC LINE (TYP.)
EX. SWING GATE
EX. SWING GATE
EX. CHAIN LINK
FENCE (TYP.)
EX. CHAIN LINK
FENCE (TYP.)
OS
F
NEMA 3R…