36C78619B0012 0003 1815 Ft Snelling LBP _ Environmental Report.pdf

View the file

Other files

File Type Posted
36C78619B0012-0005001.pdf PDF
36C78619B0012-0005000.docx DOCX document
36C78619B0012-0004000.docx DOCX document
36C78619B0012-0004001.pdf PDF
36C78619B0012-0003000.docx DOCX document
36C78619B0012-0002002.xlsx XLSX spreadsheet
36C78619B0012-0002001.pdf PDF
36C78619B0012-0002000.docx DOCX document
36C78619B0012-0001000.docx DOCX document
36C78619B0012-005.pdf PDF
36C78619B0012-003.pdf PDF
36C78619B0012-002.pdf PDF
36C78619B0012-004.pdf PDF
36C78619B0012-001.docx DOCX document
36C78619B0012-000.docx DOCX document
Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

September 20, 2018 Mr. Daniel Hayes William H. Gordon Associates 148 South Queen Street, Suite 201 Martinsburg, West Virginia, 25401 Email: dhayes@gordon.us.com

ECS Project No. 53-1815

RE: Lead Based Paint Survey – Ft. Snelling National Cemetery, Maintenance Building 3001 – 7601

34th Avenue, South Minneapolis, Hennepin County, Minnesota

Dear Mr. Hayes:

Background The subject property is located at 7601 34th Avenue, South Minneapolis, Hennepin County, Minnesota.

Currently the subject property is developed with a 7,032 square foot, single-story maintenance building (Maintenance Building 3001) which was built in 1957. Based on the planned renovation activities, a lead paint analysis was requested to determine the location, quantity and condition of suspected lead paint within the building.

Sampling and Analysis On August 22, 2018, a lead based paint survey was conducted by Mr. Bruce Carlson-Boehm, a Minnesota Department of Health (MDH) licensed Lead Inspector/Risk Assessor (#LR2789). The sampling was conducted in general accordance with the protocols described in Section 4761.2560, Lead Inspection, of the Minnesota Administrative Rules. The analysis of representative paint samples was performed within unique and homogeneous areas (areas similar in appearance, material composition, and date of application) utilizing non-destructive techniques, clean extraction tools, and personal protection equipment. ECS also evaluated the physical condition and location of sampled materials at each of the sampling locations.

Testing was performed utilizing a Heuresis Pb200i X-ray fluorescence (XRF) Analyzer. The Heuresis XRF is is a hand-held, portable, lead detector which is designed to obtain accurate, non-destructive measurements of lead concentrations in paints and coatings. X-ray fluorescence is a process whereby electrons are displaced from their atomic orbital positions, releasing a burst of energy that is characteristic of a specific element. This release of energy is then registered by the detector in then XRF instrument, which in turn categorizes the energies by element.

mailto:dhayes@gordon.us.com

2 | P a g e E C S P r o j e c t N o . 1 8 1 5 S e p t e m b e r 1 1 , 2 0 1 8

Results of the Analysis Paint is defined as lead-based by the MDH if it contains lead in concentrations equal to or greater than

1.0 milligrams per square centimeter (≥ 1.0 mg/cm2 ) or 5,000 parts per million (PPM) or greater within an “affected property”. An “affected property” refers to a residential building, school, play area, or child care facility. Please note that the onsite building is not considered to be a regulated facility.

A total of forty-two (42) readings were collected during the inspection, including three standardization readings. The XRF readings collected are summarized in Table 1. The locations of the sampled materials are shown within the attached figure.

As noted on the attached table, lead was detected above the MDH standard in the following locations:

Room 02 S. Wall – White Concrete Block Wall

Room 02 N. Wall – Red Concrete Block Wall

Room 02 N. Wall – White Concrete Block Wall

Room 03 N. Wall – Tan Concrete Block Wall

Recommendations The MDH does not presently have regulations specific to the removal of lead paint from non-affected or commercial facilities. According to the Minnesota Pollution Control Agency, if demolition/construction debris containing LBP, which still adheres to the substrate, is generated from a non-affected property, the waste may be disposed of in a permitted solid waste landfill. Additional testing is not required and peeling paint need not be encapsulated.

Positive and negative results are based on MDH guidelines. It is important to note that even if a component is negative, based on the MDH standard, it may still contain concentrations of lead in the paint, which when disturbed, may generate lead dust greater than the OSHA Permissible Exposure Limit (PEL) of 50 micrograms per cubic millimeter (µg/m3) as an 8-hour Time Weighted Average (TWA) established by the OSHA “Lead Exposure in Construction Rule (29 CFR 1926.62).”

This report summarizes our evaluation of the conditions observed at the site. The findings prepared by ECS are based upon testing performed in the building. There is a chance that undetected lead paint may exist in the building between walls or in other areas that would only be exposed during demolition.

Should materials be discovered during any demolition process that could potentially contain lead paint, samples of the material should be collected and submitted to an accredited laboratory for analytical interpretation. Our recommendations are based on the guidelines presented in USEPA, State of Minnesota, and OSHA regulations.

3 | P a g e

S e p t e m b e r 1 1 , 2 0 1 8

If you have any questions regarding our findings or opinions, please contact either of the undersigned at

(847) 279-0366. Thank you for retaining ECS Midwest, LLC for this evaluation.

Respectfully Submitted, ECS Midwest, LLC

Alissa Braun-Headrick David Kwasiborski, CIAQM Environmental Project Manager Principal Industrial Hygienist

\\S52-53-ARES\Data53\Office 53 Environmental\Industrial Hygiene\Lead\1815 St. Snelling\1815 Ft Snelling LBP.doc

S e p t e m b e r 2 0 , 2 0 1 8

Attachment

Table

Sample

No.

Description Quantity Location

Lead

(mg/cm

Remark

1 White Sheetrock Wall NA W. Wall of Room 01 in Room 02 0.00 Negative

2 White Concrete Block Wall 555 SF Room 02 S. Wall 1.50 Positive

3 White Concrete Block Wall NA Room 02 West Wall 0.01 Negative

4 Green Steel Door NA Room 02 West Human Door 0.00 Negative

5 Red Concrete Block Wall

Part of

Sample 6

Quantity Room 02 N. Wall

1.40

Positive

6 White Concrete Block Wall 555 SF Room 02 N. Wall 1.40 Positive

7 Tan Concrete Block Wall 285 SF Room 03 N. Wall 1.50 Positive

8 White Concrete Block Wall NA Room 03 N. Wall 0.02 Negative

9 White Concrete Block Wall NA Room 03 S. Wall 0.04 Negative

10 White Concrete Block Wall NA Room 03 W. Wall 0.08 Negative

11 White Concrete Block Wall NA Room 04 N. Wall 0.00 Negative

12 Light Blue Concrete Block Wall NA Roomo 04 N. Wall 0.00 Negative

13 Blue Concrete Block Wall NA Room 04 S. Wall 0.14 Negative

14 White Concrete Block Wall NA Room 04 S. Wall 0.40 Negative

15 White Concrete Block Wall NA Exterior Outside Room 05 0.03 Negative

16 White Concrete Block Wall NA Room 06 N. Wall 0.16 Negative

17 Blue Concrete Block Wall NA Room 06 N. Wall 0.13 Negative

18 Gray/Red Concrete Floor NA Room 06 0.00 Negative

19 Blue Concrete Block Wall NA Room 06 W. Wall 0.08 Negative

20 White Concrete Block Wall NA Room 06 W. Wall 0.25 Negative

21 Tan Sheetrock Wall NA Room 13 N. Wall 0.00 Negative

22 White Sheetrock Wall NA Room 13 N. Wall 0.00 Negative

23 White Concrete Block Wall 170 SF Room 13 S. Wall 1.50 Positive

24 Tan Concrete Block Wall NA Room 13 S. Wall 0.27 Negative

25 White Concrete Block Wall NA Room 08 S. Wall 0.13 Negative

26 Tan Concrete Block Wall NA Room 08 S. Wall 0.07 Negative

Calibration Results

Standard Standard Range (mg.cm2) Reading (mg/cm2)

SRM 2570 SRM <0.01 0.01

SRM 2574 SRM 0.71 ± 0.08 0.70

SRM 2571 SRM 3.58 ± 0.39 3.20

Positive paints/coatings in bold. SF - Square Feet

Table 1 Maintenance Building 3001, 7601 34th Ave. S., Minneapolis, MN

Lead Based Paint/Coating Testing Results

Sample

No.

Description Quantity Location

Lead

(mg/cm

Remark

27 Gray Concrete Floor NA Room 09 0.01 Negative

28 White Concrete Block Wall NA Room 14 E. Wall 0.40 Negative

29 Tan Steel Door NA Room 14 Door to Room 16 0.08 Negative

30 White Concrete Block Wall NA Room 16 W. Wall 0.04 Negative

31 Dark Gray Concrete Block Wall NA Room 17 W. Wall 0.03 Negative

32 White Concrete Block Wall NA Room 17 W. Wall 0.02 Negative

33 Red Concrete Block Wall NA Room 18 S. Wall 0.04 Negative

34 Light Green Concrete Block Wall NA Room 18 S. Wall 0.01 Negative

35 White Concrete Block Wall NA Room 18 W. Wall 0.01 Negative

36 Light Green Concrete Block Wall NA Room 18 W. Wall 0.00 Negative

37 Dark Gray Concrete Block Wall NA Room 18 W. Wall 0.03 Negative

38 White Concrete Block Wall NA Room 19 E. Wall 0.00 Negative

39 White Concrete Block Wall NA Room 19 N. Wall 0.01 Negative

40 White Concrete Block Wall NA Exterior E. Wall Outside Room 19 0.00 Negative

41 White Steel Door NA Exterior W. Human Door Room 18 0.01 Negative

42 White Concrete Block Wall NA Exterior W. Wall Outside Room 18 0.01 Negative

Calibration Results

Standard Standard Range (mg.cm2) Reading (mg/cm2)

SRM 2570 SRM <0.01 0.01

SRM 2574 SRM 0.71 ± 0.08 0.70

SRM 2571 SRM 3.58 ± 0.39 3.20

Positive paints/coatings in bold. SF - Square Feet

Table 2 Maintenance Building 3001, 7601 34th Ave. S., Minneapolis, MN

Lead Based Paint/Coating Testing Results

S e p t e m b e r 2 0 , 2 0 1 8

Attachment

Sampling Locations bboehmcarlson Line bboehmcarlson Typewritten Text N bboehmcarlson Typewritten Text Rm.

bboehmcarlson Typewritten Text Rm.

bboehmcarlson Typewritten Text Rm.

bboehmcarlson Typewritten Text Rm.

bboehmcarlson Typewritten Text Rm.

bboehmcarlson Line bboehmcarlson Line bboehmcarlson Typewritten Text Rm.

bboehmcarlson Typewritten Text Rm.

bboehmcarlson Typewritten Text Rm.

bboehmcarlson Callout bboehmcarlson Typewritten Text Rm.

bboehmcarlson Typewritten Text Rm.

bboehmcarlson Typewritten Text Rm.

bboehmcarlson Typewritten Text Rm.

bboehmcarlson Typewritten Text Rm.

bboehmcarlson Typewritten Text Rm.

bboehmcarlson Line bboehmcarlson Line bboehmcarlson Line bboehmcarlson Line bboehmcarlson Line bboehmcarlson Typewritten Text Rm.

bboehmcarlson Typewritten Text Rm.

bboehmcarlson Typewritten Text Rm.

bboehmcarlson Typewritten Text Rm.

bboehmcarlson Typewritten Text Rm. 08 bboehmcarlson Line bboehmcarlson Line bboehmcarlson Line bboehmcarlson Line bboehmcarlson Line bboehmcarlson Line bboehmcarlson Typewritten Text bboehmcarlson Typewritten Text bboehmcarlson Typewritten Text bboehmcarlson Typewritten Text bboehmcarlson Typewritten Text bboehmcarlson Typewritten Text bboehmcarlson Line bboehmcarlson Line bboehmcarlson Line bboehmcarlson Line bboehmcarlson Typewritten Text bboehmcarlson Typewritten Text bboehmcarlson Typewritten Text bboehmcarlson Typewritten Text bboehmcarlson Line bboehmcarlson Line bboehmcarlson Typewritten Text 11, 12 bboehmcarlson Typewritten Text 13, 14 bboehmcarlson Line bboehmcarlson Typewritten Text bboehmcarlson Line bboehmcarlson Typewritten Text 16, 17 bboehmcarlson Typewritten Text 18, 20 bboehmcarlson Line bboehmcarlson Typewritten Text bboehmcarlson Line bboehmcarlson Line bboehmcarlson Typewritten Text 21, 22 bboehmcarlson Typewritten Text 23, 24 bboehmcarlson Line bboehmcarlson Typewritten Text 25, 26 bboehmcarlson Line bboehmcarlson Typewritten Text bboehmcarlson Line bboehmcarlson Line bboehmcarlson Typewritten Text bboehmcarlson Typewritten Text bboehmcarlson Line bboehmcarlson Typewritten Text bboehmcarlson Line bboehmcarlson Typewritten Text 31, 32 bboehmcarlson Line bboehmcarlson Typewritten Text bboehmcarlson Line bboehmcarlson Typewritten Text bboehmcarlson Line bboehmcarlson Line bboehmcarlson Line bboehmcarlson Line bboehmcarlson Typewritten Text bboehmcarlson Typewritten Text bboehmcarlson Typewritten Text bboehmcarlson Typewritten Text 36, bboehmcarlson Line bboehmcarlson Line bboehmcarlson Line bboehmcarlson Typewritten Text bboehmcarlson Typewritten Text bboehmcarlson Typewritten Text