D.7 3B TAB Rooms and Devices List.xlsx
XLSX spreadsheet 14 KB Posted
- Attached to
- H241--HVAC Inspection & Balancing Services CI
- Solicitation number
- 36C26325Q0765
About this file
The file is an Excel spreadsheet (D.7 3B TAB Rooms and Devices List.xlsx) detailing the air ventilation specifications for various rooms in a medical facility. The document comprehensively lists 81 distinct rooms and spaces, providing specific details about each room's air pressure status (positive, negative, or neutral), air vent configuration, and associated terminal unit number. Rooms include patient rooms, patient toilets, isolation rooms, nurses stations, utility rooms, stairwells, and support spaces like medication rooms, break rooms, and electrical rooms.
The spreadsheet corresponds to a Department of Veterans Affairs solicitation (36C26325Q0765) for HVAC Inspection and Balancing Services at the Central Iowa Veterans Health Administration Service (VAHCS). The solicitation is set aside specifically for Service-Disabled Veteran-Owned Small Businesses (SDVOSB), indicating a targeted procurement approach to support veteran-owned businesses. The detailed room and ventilation device list suggests this document is likely a critical reference for potential contractors bidding on the HVAC inspection and balancing services contract.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Room | Description | Air Vents | Pressure -/+ | Terminal Unit | |
| 1 | 3600 | Entrance to 3B Area | Supply/Return | Positive | TU-16-34 |
| 2 | 3601 | Patient room | Supply/Return | Positive | TU-16-01 |
| 3 | 3601A | Patient Toilet | Exhaust | Negative | |
| 4 | 3602 | Patient room | Supply/Return | Positive | TU-16-02 |
| 5 | 3602A | Patient Toilet | Exhaust | Negative | |
| 6 | 3603 | Patient room | Supply/Return | Positive | TU-16-03 |
| 7 | 3603A | Patient Toilet | Exhaust | Negative | |
| 8 | 3604 | Patient room | Supply/Return | Positive | TU-16-04 |
| 9 | 3604A | Patient Toilet | Exhaust | Negative | |
| 3605 | Stairwell 1-7 | N/A | N/A | ||
| 10 | 3606 | Nurses Station West | Supply/Return | Neutral | TU-16-24 |
| 11 | 3606A | Medication Room West | Supply/Return | Positive | TU-16-37 |
| 12 | 3607 | Patient room | Supply/Return | Positive | TU-16-27 |
| 13 | 3607A | Patient Toilet | Exhaust | Negative | |
| 14 | 3608 | Patient room | Supply/Return | Positive | TU-16-28 |
| 15 | 3608A | Patient Toilet | Exhaust | Negative | |
| 16 | 3609 | Patient room | Supply/Return | Positive | TU-16-31 |
| 17 | 3609A | Patient Toilet | Exhaust | Negative | |
| 3610 | West Stairwell 1-6 | N/A | N/A | ||
| 18 | 3611 | Clean Utility | Supply/Return | Positive | TU-16-32 |
| 19 | 3612 | Consultation Room | Supply/Return | Neutral | TU-16-33 |
| 20 | 3613 | Patient room | Supply/Return | Positive | TU-16-30 |
| 21 | 3613A | Patient Toilet | Exhaust | Negative | |
| 22 | 3614 | Patient room | Supply/Return | Positive | TU-16-29 |
| 23 | 3614A | Patient Toilet | Exhaust | Negative | |
| 24 | 3615 | Patient room | Supply/Return | Positive | TU-16-26 |
| 25 | 3615A | Patient Toilet | Exhaust | Negative | |
| 26 | 3616 | Negative Pressure Patient Room (Isolation) | Supply/Exhaust | Negative | TU-16-25 |
| 27 | 3616A | Toilet Negative Pressure Patient Room (Isolation) | Exhaust | Negative | |
| 28 | 3616B | Ante Room Negative Pressure (Isolation) | Exhaust | Pos to ISO - Neg to Corr | |
| 29 | 3617 | Negative Pressure Patient Room (Isolation) | Supply/Exhaust | Negative | TU-16-23 |
| 30 | 3617A | Toilet Negative Pressure Patient Room (Isolation) | Exhaust | Negative | |
| 31 | 3617B | Ante Room Negative Pressure (Isolation) | Exhaust | Pos to ISO - Neg to Corr | |
| 3618 | Alcove | N/A | N/A | ||
| 3618A | Alcove | N/A | N/A | ||
| 32 | 3619 | Patient room | Supply/Return | Positive | TU-16-22 |
| 33 | 3619A | Patient Toilet | Exhaust | Negative | |
| 34 | 3620 | Patient room | Supply/Return | Positive | TU-16-21 |
| 35 | 3620A | Patient Toilet | Exhaust | Negative | |
| 36 | 3621 | Breakroom | Supply/Return | Negative | TU-16-19 |
| 37 | 3621A | Locker Room | Supply/Exhaust | Negative | |
| 3622 | Stairwell to Mechanical Room | N/A | N/A | ||
| 3623 | Stairwell 1-8 | N/A | N/A | ||
| 38 | 3624 | EMS Closet | Exhaust | Negative | |
| 39 | 3625 | Patient room | Supply/Return | Positive | TU-16-18 |
| 40 | 3625A | Patient Toilet | Exhaust | Negative | |
| 41 | 3626 | Patient room | Supply/Return | Positive | TU-16-17 |
| 42 | 3626A | Patient Toilet | Exhaust | Negative | |
| 43 | 3627 | Patient room | Supply/Return | Positive | TU-16-16 |
| 44 | 3627A | Patient Toilet | Exhaust | Negative | |
| 45 | 3628 | Patient room | Supply/Return | Positive | TU-16-15 |
| 46 | 3628A | Patient Toilet | Exhaust | Negative | |
| 47 | 3629 | Patient room | Supply/Return | Positive | TU-16-14 |
| 48 | 3629A | Patient Toilet | Exhaust | Negative | |
| 49 | 3630 | Patient room | Supply/Return | Positive | TU-16-12 |
| 50 | 3630A | Patient Toilet | Exhaust | Negative | |
| 51 | 3631 | Patient room | Supply/Return | Positive | TU-16-11 |
| 52 | 3631A | Patient Toilet | Exhaust | Negative | |
| 53 | 3632 | Patient room | Supply/Return | Positive | TU-16-10 |
| 54 | 3632A | Patient Toilet | Exhaust | Negative | |
| 55 | 3633 | Patient room | Supply/Return | Positive | TU-16-09 |
| 56 | 3633A | Patient Toilet | Exhaust | Negative | |
| 57 | 3634 | Patient room | Supply/Return | Positive | TU-16-08 |
| 58 | 3634A | Patient Toilet | Exhaust | Negative | |
| 59 | 3635 | Patient room | Supply/Return | Positive | TU-16-07 |
| 60 | 3635A | Patient Toilet | Exhaust | Negative | |
| 61 | 3636 | Patient room | Supply/Return | Positive | TU-16-05 |
| 62 | 3636A | Patient Toilet | Exhaust | Negative | |
| 63 | 3637 | Soiled Utility | Supply/Exhaust | Negative | TU-16-06 |
| 64 | 3638 | Clean Equipment | Supply/Return | Positive | TU-16-06 |
| 65 | 3639 | SPD Storage | Supply/Return | Positive | TU-16-38 |
| 66 | 3640 | Nurses Station East | Supply/Return | Neutral | TU-16-13 |
| 67 | 3640A | Medication Room | Supply/Return | Positive | TU-16-35 |
| 68 | 3641 | Nourishment Room | Supply/Return | Positive | TU-16-36 |
| 69 | 3642 | Nurse Manager | Supply/Return | Neutral | TU-16-20 |
| 70 | 3643 | Restroom | Exhaust | Negative | TU-16-20 |
| 71 | 3644 | Restroom | Exhaust | Negative | TU-16-20 |
| 72 | 3645 | Electrical Room | Supply | N/A | TU-16-06 |
| 73 | 3646 | Linen Room | Supply | Positive | TU-16-06 |
| Totals |
| 74 | Corridor 301B | Return | Positive |
| 75 | Corridor 302B | Return | Positive |
| 76 | Corridor 303B | Return | Positive |
| 77 | Corridor 304B | Return | Positive |
| 78 | Corridor 304AB | Return | Positive |
| 79 | Corridor 305B | Return | Positive |
| 80 | Corridor 306B | Return | Positive |
| 81 | Air Conditioning Unit 16 (AC16) and related components (VFD's, Louvers, Ducting, Coils, etc. | Supply/Return/Exhaust |
File details come from the government source that posted it. Updated .