36C25623R0089 Drawings .pdf

PDF 23 MB Posted

Attached to
Z1DA--Project #502-21-105 Replace Roof on BLDG 2 - Construction
Solicitation number
36C25623R0089
Issued by

About this file

This document outlines a federal contract opportunity for construction services. The solicitation number 36C25623R0089 is for the Z1DA--Project #502-21-105 to replace the roof on Building 2. The opportunity was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16. Interested parties should review the attached 23MB file of drawings for project specifications and requirements. The contract award will be for construction services to replace the roof at the specified location. Responses to this solicitation are due based on the timeline and instructions provided in the attached file.

View the file

Other files

File Type Posted
36C25623R0089 0003.docx DOCX document
502-21-105 RFI Register 08302023.docx DOCX document
502-21-105 Site Visit Sign in Sheet.pdf PDF
36C25623R0089 0002.docx DOCX document
36C25623R0089 0001.docx DOCX document
36C25623R0089 WD LA20230051 Mod 5 06162023 .docx DOCX document
36C25623R0089 VA Pineville - Asbestos.pdf PDF
36C25623R0089 Clay Tile Size and Color Selection_Redacted.pdf PDF
36C25623R0089 VA - Pineville Lead .pdf PDF
36C25623R0089 SOW 07072023 .docx DOCX document
36C25623R0089 Combined Specs .pdf PDF
36C25623R0089 EXHIBIT B.docx DOCX document
36C25623R0089 EXHIBIT A.docx DOCX document
36C25623R0089 502-21-105 BRAND NAME JA 05122023 Redacted.pdf PDF
36C25623R0089 PRA v2.pdf PDF
36C25623R0089 EXHIBIT E.docx DOCX document
36C25623R0089 EXHIBIT D.docx DOCX document
36C25623R0089 EXHIBIT F.docx DOCX document
36C25623R0089 EXHIBIT C.docx DOCX document
36C25623R0089 RFP.docx DOCX document
Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LS100

Life Safety Plan Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

Revisions: Date:

C : U se rs

\C

LR

\D es kt op

\B

AL

LA

R

D \2

1-

Tel: (318) 445-6571 Alexandria, LA 71303

1009 Bayou Place

Ballard CLC, Inc.

Architects Engineers Surveyors since 1908since 1908

Fax: (318) 448-0257

GDC GES

100% ISSUE

FOR CONSTRUCTION

03/28/2022

VA Medical Center, Alexandria, LA

FULLY SPRINKLERED

502-21-105

BUILDING 2 RE-ROOF

| expect a difference |

SOBE Project No. 00-3116-2021-01386

1582 Magazine Street New Orleans, Louisiana 70130

504.930.4080 | Registration No. 2964

LEGEND:

FIRE DEPARTMENT CONNECTION

PROJECT NORTH

LIFE SAFETY PLAN1

PROJECT NORTH

LIFE SAFETY WALKWAY PLAN2

A. GENERAL CONTRACTOR TO PROVIDE EGRESS "TUNNEL" PROTECTION PLAN AND

DETAILS TO VA COR PRIOR TO COMMENCING WORK. ALL EXITS MUST BE

PROTECTED FROM FALLING DEBRIS FROM ABOVE AND THE SIDES DURING ALL

PHASES OF THE WORK. ALL EXITS MUST REMAIN USABLE AT ALL TIMES. ALL

SAFETY MEASURES MUST BE IN PLACE BEFORE ANY DEMOLITION WORK CAN

BEGIN.

B. ACCESS MUST REMAIN CLEAR TO THE FDC AT ALL TIMES AND DURING ALL

PHASES OF THE WORK. PROVIDE OVERHEAD PROTECTION IF THERE IS A

CHANCE DEBRIS WILL FALL INTO THIS AREA.

C. BEFORE ANY WELDING, CUTTING, OR SOLDERING MAY OCCUR, THE GENERAL

CONTRACTOR MUST GET APPROVAL FROM THE VA FIRE DEPARTMENT AND THE

COR. SPECIAL PERMIT APPLICATIONS WILL BE REQUIRED FOR ANY WORK THAT

COULD POTENTIALLY IGNITE A FIRE.

D. ACCESS TO THE WALKWAY FROM BUILDING 2 TO BUILDING 1 MUST REMAIN OPEN

AS MUCH AS POSSIBLE. NOTICE MUST BE GIVEN 48 HOURS IN ADVANCE IF THE

AREA NEEDS TO BE CLOSED TO INSTALL NEW FLOOR COATING OR OTHER WORK.

SIGNAGE MUST BE IN PLACE AT LEAST 24 HOURS PRIOR TO ANY SHUT DOWN.

E. PROVIDE 6'-0" TALL FENCING AROUND ALL STORAGE AND WORK AREAS TO

MAINTAIN PUBLIC SAFETY.

F. ALL WOOD MATERIALS THAT ARE REPLACED (EXCEPT TRIM PIECES) IS TO BE

FIRE TREATED MATERIAL.

GENERAL LIFE SAFETY NOTES:

EGRESS ARROW

AutoCAD SHX Text

RD

AutoCAD SHX Text

RD

AutoCAD SHX Text

RD

AutoCAD SHX Text

RD

AutoCAD SHX Text

RD

AutoCAD SHX Text

RD

AutoCAD SHX Text PROTECT EXISTING COVERED WALK FROM FALLING TILE AND DEBRIS DURING CONSTRUCTION AND DEMOLITION. MAINTAIN ACCESS DURING ALL PHASES OF CONSTRUCTION. GC TO PROVIDE DETAILS TO COR FOR HOW PROTECTION FOR THIS WALKWAY AND ENTRANCE WILL BE INSTALLED - TYPICAL.

AutoCAD SHX Text NO ROOF WORK ON EXISTING COVERED CANOPY AND RAMP CANOPY. PROTECT EXISTING ROOF FROM DAMAGE DURING CONSTRUCTION AND DEMOLITION.

AutoCAD SHX Text PROVIDE TMPORARY COVERED WALKWAY FROM EMERGENCY EXIT TO RAMP. PROVIDE 6'-0" FENCING AT SIDES. 6'-0" WIDE - MINIMUM

AutoCAD SHX Text PROVIDE 6'-0" FENCING TO CLOSE OFF WORK AREAS. CONTINUE FENCING ALONG SIDES OF MAIN ENTRANCE.

AutoCAD SHX Text

MAINTAIN SAFE ACCESS TO THE BUILDING THROUGH THIS MAIN ENTRANCE

AutoCAD SHX Text MAINTAIN SAFE H/C ACCESS TO THE BUILDING THROUGH THIS MAIN ENTRANCE. PROVIDE PROTECTED COVERED WALKWAY 6'-0" WIDE - MINIMUM

AutoCAD SHX Text PROVIDE PROTECTED COVERED WALKWAY FROM MAIN ENTRANCE FOR H/C ACCESS AND TO EMERGENCY EXIT

AutoCAD SHX Text

PROVIDE 6'-0" HIGH FENCING TO MAINTAIN PUBLIC SAFETY

AutoCAD SHX Text

PROVIDE 6'-0" HIGH FENCING TO MAINTAIN PUBLIC SAFETY

AutoCAD SHX Text

CONNECTOR CORRIDOR FROM BUILDING 2 TO BUILDING 1. SEE DETAIL 2/AD100

AutoCAD SHX Text PROVIDE 6'-0" FENCING TO CLOSE OFF WORK AREAS. CONTINUE FENCING ALONG SIDES OF MAIN ENTRANCE.

AutoCAD SHX Text

CONTRACTOR STORAGE AREA

AutoCAD SHX Text

CONTRACTOR STORAGE AREA

AutoCAD SHX Text

CONTRACTOR STORAGE AREA

AutoCAD SHX Text

CONTRACTOR STORAGE AREA

AutoCAD SHX Text

MAINTAIN CLEAR ACCESS TO FDC DURING ALL PHASES OF CONSTRUCTION

AutoCAD SHX Text

FDC

AutoCAD SHX Text

FDC

AutoCAD SHX Text

EMERGENCY EXIT

AutoCAD SHX Text

EMERGENCY EXIT

AutoCAD SHX Text

MAIN ENTRANCE

AutoCAD SHX Text

REFER TO NOTE "D" IN THE GENERAL LIFE SAFETY NOTES BELOW.

AutoCAD SHX Text

CONNECTOR CORRIDOR FROM BUILDING 2 TO BUILDING 1.

AutoCAD SHX Text

BUILDING 1

AutoCAD SHX Text

BUILDING 2

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"