36C25620B0003-0001004.pdf

PDF Posted

Attached to
564-17-135\F\ B21 Upgrade Restrooms ADA Compliance
Solicitation number
36C25620B0003
Issued by

About this file

36C25620B0003 0001 564-17-135 Renovate B21 Basement Restrooms.pdf

View the file

Other files

File Type Posted
36C25620B0003-0004001.docx DOCX document
36C25620B0003-0004000.docx DOCX document
36C25620B0003-0003000.docx DOCX document
36C25620B0003-0002000.docx DOCX document
36C25620B0003-0002001.pdf PDF
36C25620B0003-0001001.pdf PDF
36C25620B0003-0001002.pdf PDF
36C25620B0003-0001000.docx DOCX document
36C25620B0003-0001003.pdf PDF
36C25620B0003-002.docx DOCX document
36C25620B0003-001.docx DOCX document
36C25620B0003-003.pdf PDF
Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MENS

L230

WOMENS

L231

A Demolition Floor Plan L230-21, L231-21

ETERANS EALTH ARE YSTEMV H C S

OF THE ZARKSO

Engineering Service

1 5

AD100

564-17-TBD

26 JUNE 2017

DEMOLITION FLOOR PLAN

RENOVATE L230, L231 B-21

NTS

VA Healthcare System of the Ozarks

ENG

REMOVE AND STORE EXISTING DOOR FOR MODIFICATION AND

RE-USE. DEMO EXISTING DOOR FRAME FOR REFRAMING

OPENING.

KEY NOTES FOR DEMO PLAN:

DEMO AND DISPOSE OF EXISTING FLOOR COVERING, WALL

MOUNTED CERAMIC TILE, AND BASE IN PREPARATION FOR NEW

RESINOUS EPOXY FLOORING AND INTEGRAL BASE/WALL

COVERING.

DEMO AND DISPOSE OF EXISTING WATER CLOSET PARTITION.

REMOVE EXISTING GRAB BARS AND STORE FOR RELOCATION,

RE-USE.

REMOVE EXISTING WALL HUNG TOILET. PRESERVE AND

PROVIDE TO VHSO ENGINEERING (COR). SEE PLUMBING SHEET

P100 FOR FURTHER PLUMBING DEMO INSTRUCTIONS.

GENERAL NOTES:

1. MEASUREMENTS/LOCATIONS ARE APPROXIMATE AND

SHALL BE VERIFIED BY THE CONTRACTOR. VA WILL NOT

BE RESPONSIBLE FOR ANY ERROR OR VARIATION IN ANY

MEASUREMENTS OR DATA LISTED.

2. APPROPRIATE PPE AND SAFETY PROCEDURES

REQUIRED.

3. ICRA (INFECTION CONTROL RISK ASSESSMENT) WILL BE

PROVIDED BY VHSO PRIOR TO BEGINNING ANY WORK.

ICRA REQUIREMENTS SHALL BE FOLLOWED BY

CONTRACTOR.

4. ALL WORK MUST BE SCHEDULED AND COORDINATED IN

ADVANCE WITH COR.

5. REFER TO SOW AND SPECIFICATIONS FOR ADDITIONAL

INFORMATION.

ICRA DUST/SMOKE BARRIER. PROVIDE/ INSTALL TEMPORARY

ACCESS DOOR WITH KEY PUNCH COMBINATION LOCK SET.

PROVIDE/INSTALL NEGATIVE PRESSURE INDICATOR AT THIS

LOCATION (EQUAL TO BAULIN "BALL IN TUBE").

AutoCAD SHX Text

UP

AutoCAD SHX Text

NTS

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Building Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Sheet

AutoCAD SHX Text Notes and/or Revisions:

AutoCAD SHX Text Date

AutoCAD SHX Text

CUSTOM VA FORM 08-6231B, MAY 2012

AutoCAD SHX Text of

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Scale:

AutoCAD SHX Text One inch or not to scale!

AutoCAD SHX Text Approved: VHSO Associate Director

AutoCAD SHX Text Approved: Engineering Service Chief

AutoCAD SHX Text

REVISED PER DESIGN REVIEW MEETING 5/13/16

AutoCAD SHX Text N/A

AutoCAD SHX Text N/A

A New Floor Plan L230-21, L231-21

WOMENS

L231

MENS

L230

ETERANS EALTH ARE YSTEMV H C S

OF THE ZARKSO

Engineering Service

2 5

AE100

564-17-TBD

26 JUNE 2017

NEW FLOOR PLAN

RENOVATE L230, L231 B-21

NTS

VA Healthcare System of the Ozarks

ENG

NEW HEADER AND DOOR FRAME FOR 7'0X3'6" DOOR. EXISTING

DOOR TRIMMED TO FIT NEW FRAME AND RE-INSTALLED WITH

CONTINUOUS HINGE..

KEY NOTES FOR FLOOR PLAN:

NEW ELECTROMECHANICAL DOOR OPERATOR INSTALLED ON

NEW HEADER.

NEW PUSH PLATE WALL MOUNTED DOOR SWITCH (WIRELESS,

BATTERY POWERED) TO ACTIVATE NEW ELECTROMECHANICAL

DOOR OPERATOR. MOUNT TO NEW BACK BOX INSTALLED IN

EXISTING WALLS.

EXISTING GRAB BARS RELOCATED (INSTALL BLOCKING IN

EXISTING WALLS TO SUPPORT).

NEW WATER CLOSET PARTITION AND DOOR. SECURE TO

FLOOR, WALLS, AND STRUCTURE ABOVE CEILING (MODIFY/ADD

TO EXISTING SUPPORTS AS REQUIRED).

GENERAL NOTES:

1. MEASUREMENTS/LOCATIONS ARE APPROXIMATE AND

SHALL BE VERIFIED BY THE CONTRACTOR. VA WILL NOT

BE RESPONSIBLE FOR ANY ERROR OR VARIATION IN ANY

MEASUREMENTS OR DATA LISTED.

2. APPROPRIATE PPE AND SAFETY PROCEDURES

REQUIRED.

3. ICRA (INFECTION CONTROL RISK ASSESSMENT) WILL BE

PROVIDED BY VHSO PRIOR TO BEGINNING ANY WORK.

ICRA REQUIREMENTS SHALL BE FOLLOWED BY

CONTRACTOR.

4. ALL WORK MUST BE SCHEDULED AND COORDINATED IN

ADVANCE WITH COR.

5. REFER TO SOW AND SPECIFICATIONS FOR ADDITIONAL

INFORMATION.

AutoCAD SHX Text

UP

AutoCAD SHX Text

NTS

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Building Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Sheet

AutoCAD SHX Text Notes and/or Revisions:

AutoCAD SHX Text Date

AutoCAD SHX Text

CUSTOM VA FORM 08-6231B, MAY 2012

AutoCAD SHX Text of

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Scale:

AutoCAD SHX Text One inch or not to scale!

AutoCAD SHX Text Approved: VHSO Associate Director

AutoCAD SHX Text Approved: Engineering Service Chief

AutoCAD SHX Text

REVISED PER DESIGN REVIEW MEETING 5/13/16

AutoCAD SHX Text N/A

N/A

A New Floor Plan L230-21, L231-21

L231

MENS

L230

DOOR AND FRAME SCHEDULE

ETERANS EALTH ARE YSTEMV H C S

OF THE ZARKSO

Engineering Service

3 5

AE200

564-17-TBD

30 JUNE 2017

FINISHES AND FINISH SCHEDULESRENOVATE L230, L231 B21

VARIES

VA Healthcare System of the Ozarks

ENG

AutoCAD SHX Text

UP

AutoCAD SHX Text

NTS

AutoCAD SHX Text P-01

AutoCAD SHX Text P-02

AutoCAD SHX Text P-01

AutoCAD SHX Text P-02

AutoCAD SHX Text

AT-01

AutoCAD SHX Text

RES-01

AutoCAD SHX Text

AT-01

AutoCAD SHX Text

RES-01

AutoCAD SHX Text

ROOM FINISH SCHEDULE

AutoCAD SHX Text

NAME

AutoCAD SHX Text

MARK

AutoCAD SHX Text

FLOOR

AutoCAD SHX Text

BASE

AutoCAD SHX Text

WALLS

AutoCAD SHX Text

TRIM

AutoCAD SHX Text

CEILING

AutoCAD SHX Text

HORIZ MILLWORK

AutoCAD SHX Text

VERT MILLWORK

AutoCAD SHX Text

MENS RESTROOM

AutoCAD SHX Text L230

AutoCAD SHX Text

RES-01

AutoCAD SHX Text P-01

AutoCAD SHX Text P-02

AutoCAD SHX Text

AT-01

AutoCAD SHX Text

WOMENS RESTROOM

AutoCAD SHX Text L231

AutoCAD SHX Text

RES-01

AutoCAD SHX Text P-01

AutoCAD SHX Text P-02

AutoCAD SHX Text

AT-01

AutoCAD SHX Text

RES-01

AutoCAD SHX Text

RES-01

AutoCAD SHX Text

MODIFICATIONS / REMARKS

AutoCAD SHX Text

HDW SET

AutoCAD SHX Text

MATL

AutoCAD SHX Text

DOOR

AutoCAD SHX Text

TYPE

AutoCAD SHX Text

ROOM NO.

AutoCAD SHX Text

RATING (LABEL)

AutoCAD SHX Text

HT

AutoCAD SHX Text

WIDTH

AutoCAD SHX Text

EXISTING

AutoCAD SHX Text L230

AutoCAD SHX Text L231

AutoCAD SHX Text

EXISTING

AutoCAD SHX Text

EXISTING

AutoCAD SHX Text

EXISTING

AutoCAD SHX Text

FRAME TYPE

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text

WD

AutoCAD SHX Text

WD

AutoCAD SHX Text 7'-0"

AutoCAD SHX Text 3'-6"

AutoCAD SHX Text

EXISTING DOOR TRIMMED TO 7'0, INSTALL IN NEW FRAME WITH CONTINUOUS SS HINGE

AutoCAD SHX Text 7'-0"

AutoCAD SHX Text 3'-6"

AutoCAD SHX Text

PAIR

AutoCAD SHX Text

EXISTING DOOR TRIMMED TO 7'0, INSTALL IN NEW FRAME WITH CONTINUOUS SS HINGE

AutoCAD SHX Text

MATERIAL TYPE LEGEND

AutoCAD SHX Text

MARK

AutoCAD SHX Text

MANUFACTURER

AutoCAD SHX Text

PATTERN / LINE

AutoCAD SHX Text

STYLE

AutoCAD SHX Text

SIZE

AutoCAD SHX Text

COLOR

AutoCAD SHX Text

FINISH

AutoCAD SHX Text

COMMENTS

AutoCAD SHX Text

FLOORING

AutoCAD SHX Text

RESILIENT SHEET FLOORING - SPEC SECTION 09 65 16

AutoCAD SHX Text

RESINOUS FLOORING / INTEGRAL BASE - SPEC SECTION 09 67 23.20

AutoCAD SHX Text

RES-01

AutoCAD SHX Text

TNEMEC

AutoCAD SHX Text

1/8" FLAKE

AutoCAD SHX Text

1C-224-0506 DECO-FLAKE

AutoCAD SHX Text

USE RES-2C-284-0000-DECO-CLEAR

AutoCAD SHX Text

BASE

AutoCAD SHX Text

RUBBER BASE - SPEC SECTION 09 65 13

AutoCAD SHX Text

WALLS

AutoCAD SHX Text

PAINT - SPEC SECTION 09 91 00

AutoCAD SHX Text P-01

AutoCAD SHX Text

*SHERWIN-WILLIAMS

AutoCAD SHX Text

SEMI-GLOSS

AutoCAD SHX Text

USE FOR ALL WALLS AND SOFFITS IN RESTROOMS

AutoCAD SHX Text P-02

AutoCAD SHX Text

*SHERWIN-WILLIAMS

AutoCAD SHX Text

SW6385 DOVER WHITE

AutoCAD SHX Text

GLOSS

AutoCAD SHX Text

CEILINGS

AutoCAD SHX Text

ACOUSTICAL CEILING TILE AND GRID - SPEC SECTION 09 51 00

AutoCAD SHX Text

AT-01

AutoCAD SHX Text

*USG

AutoCAD SHX Text

SANDRIFT CLIMAPLUS

AutoCAD SHX Text

#808 SHADOWLINE

AutoCAD SHX Text 24" x 24" x 3/4"

AutoCAD SHX Text

050 FLAT WHITE

AutoCAD SHX Text

15/16" DONN DX GRID IN WHITE

AutoCAD SHX Text

COUNTERTOPS

AutoCAD SHX Text

SOLID SURFACE - SPEC SECTION 12 36 00

AutoCAD SHX Text

RESINOUS WALL COATINGS - SPEC SECTION 09 67 23.20

AutoCAD SHX Text

RESW-01

AutoCAD SHX Text

TNEMEC

AutoCAD SHX Text

1/4 "FLAKE

AutoCAD SHX Text

1C-224-0506 DECO-FLAKE

AutoCAD SHX Text

GLOSS

AutoCAD SHX Text

USE FOR ALL DOOR TRIM AND CEILINGS

AutoCAD SHX Text

USE RES-2C-284-0000-DECO-CLEAR

AutoCAD SHX Text

*OR EQUAL

AutoCAD SHX Text

PLASTIC LAMINATE - SPEC SECTION 12 36 00

AutoCAD SHX Text

EXISTING TO BE RE-USED

AutoCAD SHX Text N/A

AutoCAD SHX Text N/A

AutoCAD SHX Text N/A

AutoCAD SHX Text

SW 7519 MEXICAN SAND

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Building Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Sheet

AutoCAD SHX Text Notes and/or Revisions:

AutoCAD SHX Text Date

AutoCAD SHX Text

CUSTOM VA FORM 08-6231B, MAY 2012

AutoCAD SHX Text of

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Scale:

AutoCAD SHX Text One inch or not to scale!

AutoCAD SHX Text Approved: VHSO Associate Director

Approved: Engineering Service Chief

A Plumbing Demolition Plan L231-21

ETERANS EALTH ARE YSTEMV H C S

OF THE ZARKSO

Engineering Service

4 5 P100

564-17-TBD

30 JUNE 2017

PLUMBING DEMOLITION PLANRENOVATE L230, L231 B21

NTS

VA Healthcare System of the Ozarks

ENG

TOILET TO BE DEMO'D AND REMOVED. CAP COLD WATER LINE

AT TEE FROM BRANCH. CAP SANITARY INSIDE EXISTING WALL.

INSTALL 8"X8" ACCESS PANEL AT SANITARY CAP LOCATION.

KEY NOTES FOR PLUMBING PLAN:

GENERAL NOTES:

1. MEASUREMENTS/LOCATIONS ARE APPROXIMATE AND

SHALL BE VERIFIED BY THE CONTRACTOR. VA WILL NOT

BE RESPONSIBLE FOR ANY ERROR OR VARIATION IN ANY

MEASUREMENTS OR DATA LISTED.

2. APPROPRIATE PPE AND SAFETY PROCEDURES

REQUIRED.

3. ICRA (INFECTION CONTROL RISK ASSESSMENT) WILL BE

PROVIDED BY VHSO PRIOR TO BEGINNING ANY WORK.

ICRA REQUIREMENTS SHALL BE FOLLOWED BY

CONTRACTOR.

4. ALL WORK MUST BE SCHEDULED AND COORDINATED IN

ADVANCE WITH COR.

5. REFER TO SOW AND SPECIFICATIONS FOR ADDITIONAL

INFORMATION.

AutoCAD SHX Text

UP

AutoCAD SHX Text

LOBBY

AutoCAD SHX Text C-L001

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C-L002

AutoCAD SHX Text

AutoCAD SHX Text

WOMEN

AutoCAD SHX Text 21-L231

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

MEN

AutoCAD SHX Text 21-L230

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text C-L004

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

STAIR 1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text P-1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text P-2

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text P-3

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PF-300

AutoCAD SHX Text P-421

AutoCAD SHX Text P-103

AutoCAD SHX Text P-103

AutoCAD SHX Text P-103

AutoCAD SHX Text P-421

AutoCAD SHX Text P-202

AutoCAD SHX Text P-609

AutoCAD SHX Text

1" HWR UP

AutoCAD SHX Text

2" HW UP

AutoCAD SHX Text

2 1/2" CW UP

AutoCAD SHX Text

6" ST UP

AutoCAD SHX Text (2168 )

AutoCAD SHX Text

6" ERD UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

LOBBY

AutoCAD SHX Text C-L001

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C-L002

AutoCAD SHX Text

AutoCAD SHX Text

WOMEN

AutoCAD SHX Text 21-L231

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

MEN

AutoCAD SHX Text 21-L230

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text C-L004

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

STAIR 1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text P-1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text P-2

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text P-3

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NTS

AutoCAD SHX Text

MECHANICAL AND ELECTRICAL SYMBOL LEGEND

AutoCAD SHX Text

DENOTES CONDUIT RUN CONCEALED IN WALL, ABOVE CEILINGS, EXPOSED IN

AutoCAD SHX Text

UNFINISHED AREAS. RUN PARALLEL OR PERPENDICULAR TO STRUCTURE OR WALL.

AutoCAD SHX Text

RECESSED OR SURFACE MOUNTED LIGHTING FIXTURE CONNECTED TO NORMAL

AutoCAD SHX Text

BRANCH CIRCUIT. SEE LIGHTING FIXTURE SCHEDULE FOR EXACT REQUIREMENTS.

AutoCAD SHX Text

RECESSED OR SURFACE MOUNTED LIGHTING FIXTURE CONNECTED TO LIFE SAFETY BRANCH

AutoCAD SHX Text

CIRCUIT FOR PROJECTS W/ GENERATOR OR PROVIDE LOCAL BATTERY PACK W/O GEN.

AutoCAD SHX Text

SEE LIGHTING FIXTURE SCHEDULE FOR EXACT REQUIREMENTS. LETTER INDICATES TYPE.

AutoCAD SHX Text

CEILING MOUNTED EXIT SIGN, SHADED AREA INDICATES FACE WITH DIRECTIONAL ARROWS AS

AutoCAD SHX Text

SHOWN. SEE LTG. FIXT. SCHEDULE FOR EXACT REQUIREMENTS. CONNECT TO UNSWITCHED

AutoCAD SHX Text

BRANCH CKT. INDICATED ON DWGS. SUBSCRIPT "WG" WHEN INDICATED DENOTES WIREGUARD.

AutoCAD SHX Text S

AutoCAD SHX Text

SINGLE-POLE, 20 AMP, 120/277 VOLT, TOGGLE SWITCH IN FLUSH (FINISHED SPACES)

AutoCAD SHX Text

OR SURFACE (UNFINISHED SPACES) OUTLET BOX. MOUNT 44" A.F.F. UNLESS

AutoCAD SHX Text

OTHERWISE INDICATED.

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text

SINGLE POLE, 20 AMP, 120/277 VOLT, SWITCH CONNECTED TO EMERGENCY BRANCH CKT.

AutoCAD SHX Text

PROVIDE RED SWITCH. MOUNT IN FLUSH (FINISHED SPACES) OR SURFACE (UNFINISHED

AutoCAD SHX Text

SPACES) OUTLET BOX. MOUNT 44" A.F.F. UNLESS OTHERWISE INDICATED.

AutoCAD SHX Text

20 AMP, 125 VOLT, 3 WIRE DUPLEX RECEPTACLE IN FLUSH (FINISHED SPACES) OR SURFACE

AutoCAD SHX Text

(UNFINISHED SPACES) OUTLET BOX. MOUNT 18" A.F.F. UNLESS OTHERWISE INDICATED.

AutoCAD SHX Text

20 AMP, 125 VOLT, 3 WIRE DUPLEX RECEPTACLE IN FLUSH (FINISHED SPACES) OR SURFACE

AutoCAD SHX Text

(UNFINISHED SPACES) OUTLET BOX. MOUNT 44" ABOVE FINISHED FLOOR, 4" ABOVE DESK/

AutoCAD SHX Text

COUNTERTOP, OR 2" ABOVE BACKSPLASH UNLESS OTHERWISE INDICATED.

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

20 AMP, 125 VOLT, 3 WIRE DUPLEX RECEPTACLE CONNECTED TO EMERGENCY BRANCH

AutoCAD SHX Text

CIRCUIT. PROVIDE RED RECEPTACLE AND ENGRAVED CIRCUIT DESIGNATION NAMEPLATE

AutoCAD SHX Text

UNLESS OTHERWISE INDICATED.

AutoCAD SHX Text

GF

AutoCAD SHX Text

GF

AutoCAD SHX Text

GF

AutoCAD SHX Text

GF

AutoCAD SHX Text

20 AMP, 125 VOLT, 3 WIRE GROUND FAULT TYPE DUPLEX RECEPTACLE(S).

AutoCAD SHX Text

MOUNTING AS INDICATED.

AutoCAD SHX Text

CR

AutoCAD SHX Text

SECURITY SYSTEM CARD READER FLUSH MOUNTED 44" A.F.F. UNLESS OTHERWISE INDICATED.

AutoCAD SHX Text S

AutoCAD SHX Text

INTERCOM/SOUND SYSTEM FLUSH MOUNTED CEILING SPEAKER.

AutoCAD SHX Text

FIRE ALARM INTERCOM/SOUND SYSTEM FLUSH MOUNTED CEILING SPEAKER.

AutoCAD SHX Text F

AutoCAD SHX Text

SUPPLY AIR DIFFUSER

AutoCAD SHX Text

RETURN AIR DIFFUSER

AutoCAD SHX Text T

AutoCAD SHX Text

ROOM CONTROL THERMOSTAT; WALL MOUNTED TOP OF THERMOSTAT AT 48" AFF

AutoCAD SHX Text

TWO 20 AMP, 125 VOLT, 3 WIRE RECEPTACLES IN FLUSH (FINISHED SPACES) OR

AutoCAD SHX Text SURFACE (UNFINISHED SPACES) 2-GANG OUTLET BOX SINGLE YOKE. MOUNT 18" A.F.F. UNLESS

AutoCAD SHX Text

OTHERWISE INDICATED.

AutoCAD SHX Text

TELECOMMUNICATIONS OUTLET MOUNTED 18" GAFF U.O.I. SUBSCRIPT 'XD' AND/OR 'XV' AND

AutoCAD SHX Text

/OR 'XF', WHEN SHOWN, DENOTES NUMBER OF DATA AND/OR VOICE CABLES AND/OR FIBERS

AutoCAD SHX Text

AND JACKS RESPECTIVELY. SUBSCRIPT "WT" DENOTES WIRELESS TRANSMITTER.

AutoCAD SHX Text C

AutoCAD SHX Text

DENOTES CEILING MOUNTED

AutoCAD SHX Text

SUSPENDED ACOUSTICAL CEILING

AutoCAD SHX Text

SUSPENDED GWB

AutoCAD SHX Text R

AutoCAD SHX Text

SURFACE LIGHTING FIXTURE CONNECTED TO NORMAL

AutoCAD SHX Text

BRANCH CIRCUIT. SEE LIGHTING FIXTURE SCHEDULE FOR EXACT REQUIREMENTS.

AutoCAD SHX Text

RECESSED CAN LIGHTING FIXTURE CONNECTED TO NORMAL

AutoCAD SHX Text

BRANCH CIRCUIT. SEE LIGHTING FIXTURE SCHEDULE FOR EXACT REQUIREMENTS.

AutoCAD SHX Text S

AutoCAD SHX Text D

AutoCAD SHX Text

SINGLE-POLE, 20 AMP, 120/277 VOLT, DIMMER SWITCH IN FLUSH (FINISHED SPACES)

AutoCAD SHX Text

OR SURFACE (UNFINISHED SPACES) OUTLET BOX. MOUNT 44" A.F.F. UNLESS

AutoCAD SHX Text

OTHERWISE INDICATED. DIMMER SWITCH MUST BE COMPATIBLE WITH FIXTURE.

AutoCAD SHX Text

TELECOMMUNICATIONS OUTLET CEILING MOUNTED U.O.I. SUBSCRIPT 'XD' AND/OR 'XV' AND

AutoCAD SHX Text

/OR 'XF', WHEN SHOWN, DENOTES NUMBER OF DATA AND/OR VOICE CABLES AND/OR FIBERS

AutoCAD SHX Text

AND JACKS RESPECTIVELY. EXACT LOCATION TO BE DETERMINED BY COR.

AutoCAD SHX Text

WALL MOUNTED TELEPHONE JACK. LOCATED 44" AFF.

AutoCAD SHX Text CABLE TELEVISION OUTLET. REMOVE OLD TV CABLES AND REPLACE WITH NEW TO MATCH EXISTING SYSTEM.

AutoCAD SHX Text

TV

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Building Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Sheet

AutoCAD SHX Text Notes and/or Revisions:

AutoCAD SHX Text Date

AutoCAD SHX Text

CUSTOM VA FORM 08-6231B, MAY 2012

AutoCAD SHX Text of

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Scale:

AutoCAD SHX Text One inch or not to scale!

AutoCAD SHX Text Approved: VHSO Associate Director

A New Electrical Plan L230-21, L231-21

L231

MENS

L230

ETERANS EALTH ARE YSTEMV H C S

OF THE ZARKSO

Engineering Service

5 5

EP100

564-17-TBD

30 JUNE 2017

NEW ELECTRICAL RECEPTACLE POWER PLANRENOVATE L230, L231 B21

NTS

VA Healthcare System of the Ozarks

ENG

EXISTING GFCI RECEPTACLES, EXISTING CIRCUIT.

KEY NOTES FOR PLUMBING PLAN:

GENERAL NOTES:

1. MEASUREMENTS/LOCATIONS ARE APPROXIMATE AND

SHALL BE VERIFIED BY THE CONTRACTOR. VA WILL NOT

BE RESPONSIBLE FOR ANY ERROR OR VARIATION IN ANY

MEASUREMENTS OR DATA LISTED.

2. APPROPRIATE PPE AND SAFETY PROCEDURES

REQUIRED.

3. ICRA (INFECTION CONTROL RISK ASSESSMENT) WILL BE

PROVIDED BY VHSO PRIOR TO BEGINNING ANY WORK.

ICRA REQUIREMENTS SHALL BE FOLLOWED BY

CONTRACTOR.

4. ALL WORK MUST BE SCHEDULED AND COORDINATED IN

ADVANCE WITH COR.

5. REFER TO SOW AND SPECIFICATIONS FOR ADDITIONAL

INFORMATION.

NEW HOSPITAL GRADE DUPLEX RECEPTACLE. CONNECT TO

EXISTING CIRCUIT SHOWN. INSTALL IN NEW CUT-IN 2X4 BACK

BOX. COORDINATE HEIGHT AND EXACT LOCATION WITH

AUTOMATIC DOOR OPENER INSTALLER.

NEW WIRELESS, BATTERY OPERATED PUSH PLATES FOR NEW

DOOR OPENERS. BACK BOX FOR PUSH PLATES IN EXISTING

WALLS TO BE INSTALLED BY ELECTRICAL CONTRACTOR.

AutoCAD SHX Text

UP

AutoCAD SHX Text

NTS

AutoCAD SHX Text

GFCI

AutoCAD SHX Text

AutoCAD SHX Text

GFCI

AutoCAD SHX Text

AutoCAD SHX Text

GFCI

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

MECHANICAL AND ELECTRICAL SYMBOL LEGEND

AutoCAD SHX Text

DENOTES CONDUIT RUN CONCEALED IN WALL, ABOVE CEILINGS, EXPOSED IN

AutoCAD SHX Text

UNFINISHED AREAS. RUN PARALLEL OR PERPENDICULAR TO STRUCTURE OR WALL.

AutoCAD SHX Text

RECESSED OR SURFACE MOUNTED LIGHTING FIXTURE CONNECTED TO NORMAL

AutoCAD SHX Text

BRANCH CIRCUIT. SEE LIGHTING FIXTURE SCHEDULE FOR EXACT REQUIREMENTS.

AutoCAD SHX Text

RECESSED OR SURFACE MOUNTED LIGHTING FIXTURE CONNECTED TO LIFE SAFETY BRANCH

AutoCAD SHX Text

CIRCUIT FOR PROJECTS W/ GENERATOR OR PROVIDE LOCAL BATTERY PACK W/O GEN.

AutoCAD SHX Text

SEE LIGHTING FIXTURE SCHEDULE FOR EXACT REQUIREMENTS. LETTER INDICATES TYPE.

AutoCAD SHX Text

CEILING MOUNTED EXIT SIGN, SHADED AREA INDICATES FACE WITH DIRECTIONAL ARROWS AS

AutoCAD SHX Text

SHOWN. SEE LTG. FIXT. SCHEDULE FOR EXACT REQUIREMENTS. CONNECT TO UNSWITCHED

AutoCAD SHX Text

BRANCH CKT. INDICATED ON DWGS. SUBSCRIPT "WG" WHEN INDICATED DENOTES WIREGUARD.

AutoCAD SHX Text S

AutoCAD SHX Text

SINGLE-POLE, 20 AMP, 120/277 VOLT, TOGGLE SWITCH IN FLUSH (FINISHED SPACES)

AutoCAD SHX Text

OR SURFACE (UNFINISHED SPACES) OUTLET BOX. MOUNT 44" A.F.F. UNLESS

AutoCAD SHX Text

OTHERWISE INDICATED.

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text

SINGLE POLE, 20 AMP, 120/277 VOLT, SWITCH CONNECTED TO EMERGENCY BRANCH CKT.

AutoCAD SHX Text

PROVIDE RED SWITCH. MOUNT IN FLUSH (FINISHED SPACES) OR SURFACE (UNFINISHED

AutoCAD SHX Text

SPACES) OUTLET BOX. MOUNT 44" A.F.F. UNLESS OTHERWISE INDICATED.

AutoCAD SHX Text

20 AMP, 125 VOLT, 3 WIRE DUPLEX RECEPTACLE IN FLUSH (FINISHED SPACES) OR SURFACE

AutoCAD SHX Text

(UNFINISHED SPACES) OUTLET BOX. MOUNT 18" A.F.F. UNLESS OTHERWISE INDICATED.

AutoCAD SHX Text

20 AMP, 125 VOLT, 3 WIRE DUPLEX RECEPTACLE IN FLUSH (FINISHED SPACES) OR SURFACE

AutoCAD SHX Text

(UNFINISHED SPACES) OUTLET BOX. MOUNT 44" ABOVE FINISHED FLOOR, 4" ABOVE DESK/

AutoCAD SHX Text

COUNTERTOP, OR 2" ABOVE BACKSPLASH UNLESS OTHERWISE INDICATED.

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

20 AMP, 125 VOLT, 3 WIRE DUPLEX RECEPTACLE CONNECTED TO EMERGENCY BRANCH

AutoCAD SHX Text

CIRCUIT. PROVIDE RED RECEPTACLE AND ENGRAVED CIRCUIT DESIGNATION NAMEPLATE

AutoCAD SHX Text

UNLESS OTHERWISE INDICATED.

AutoCAD SHX Text

GF

AutoCAD SHX Text

GF

AutoCAD SHX Text

GF

AutoCAD SHX Text

GF

AutoCAD SHX Text

20 AMP, 125 VOLT, 3 WIRE GROUND FAULT TYPE DUPLEX RECEPTACLE(S).

AutoCAD SHX Text

MOUNTING AS INDICATED.

AutoCAD SHX Text

CR

AutoCAD SHX Text

SECURITY SYSTEM CARD READER FLUSH MOUNTED 44" A.F.F. UNLESS OTHERWISE INDICATED.

AutoCAD SHX Text S

AutoCAD SHX Text

INTERCOM/SOUND SYSTEM FLUSH MOUNTED CEILING SPEAKER.

AutoCAD SHX Text

FIRE ALARM INTERCOM/SOUND SYSTEM FLUSH MOUNTED CEILING SPEAKER.

AutoCAD SHX Text F

AutoCAD SHX Text

SUPPLY AIR DIFFUSER

AutoCAD SHX Text

RETURN AIR DIFFUSER

AutoCAD SHX Text T

AutoCAD SHX Text

ROOM CONTROL THERMOSTAT; WALL MOUNTED TOP OF THERMOSTAT AT 48" AFF

AutoCAD SHX Text

TWO 20 AMP, 125 VOLT, 3 WIRE RECEPTACLES IN FLUSH (FINISHED SPACES) OR

AutoCAD SHX Text SURFACE (UNFINISHED SPACES) 2-GANG OUTLET BOX SINGLE YOKE. MOUNT 18" A.F.F. UNLESS

AutoCAD SHX Text

OTHERWISE INDICATED.

AutoCAD SHX Text

TELECOMMUNICATIONS OUTLET MOUNTED 18" GAFF U.O.I. SUBSCRIPT 'XD' AND/OR 'XV' AND

AutoCAD SHX Text

/OR 'XF', WHEN SHOWN, DENOTES NUMBER OF DATA AND/OR VOICE CABLES AND/OR FIBERS

AutoCAD SHX Text

AND JACKS RESPECTIVELY. SUBSCRIPT "WT" DENOTES WIRELESS TRANSMITTER.

AutoCAD SHX Text C

AutoCAD SHX Text

DENOTES CEILING MOUNTED

AutoCAD SHX Text

SUSPENDED ACOUSTICAL CEILING

AutoCAD SHX Text

SUSPENDED GWB

AutoCAD SHX Text R

AutoCAD SHX Text

SURFACE LIGHTING FIXTURE CONNECTED TO NORMAL

AutoCAD SHX Text

BRANCH CIRCUIT. SEE LIGHTING FIXTURE SCHEDULE FOR EXACT REQUIREMENTS.

AutoCAD SHX Text

RECESSED CAN LIGHTING FIXTURE CONNECTED TO NORMAL

AutoCAD SHX Text

BRANCH CIRCUIT. SEE LIGHTING FIXTURE SCHEDULE FOR EXACT REQUIREMENTS.

AutoCAD SHX Text S

AutoCAD SHX Text D

AutoCAD SHX Text

SINGLE-POLE, 20 AMP, 120/277 VOLT, DIMMER SWITCH IN FLUSH (FINISHED SPACES)

AutoCAD SHX Text

OR SURFACE (UNFINISHED SPACES) OUTLET BOX. MOUNT 44" A.F.F. UNLESS

AutoCAD SHX Text

OTHERWISE INDICATED. DIMMER SWITCH MUST BE COMPATIBLE WITH FIXTURE.

AutoCAD SHX Text

TELECOMMUNICATIONS OUTLET CEILING MOUNTED U.O.I. SUBSCRIPT 'XD' AND/OR 'XV' AND

AutoCAD SHX Text

/OR 'XF', WHEN SHOWN, DENOTES NUMBER OF DATA AND/OR VOICE CABLES AND/OR FIBERS

AutoCAD SHX Text

AND JACKS RESPECTIVELY. EXACT LOCATION TO BE DETERMINED BY COR.

AutoCAD SHX Text

WALL MOUNTED TELEPHONE JACK. LOCATED 44" AFF.

AutoCAD SHX Text CABLE TELEVISION OUTLET. REMOVE OLD TV CABLES AND REPLACE WITH NEW TO MATCH EXISTING SYSTEM.

AutoCAD SHX Text

TV

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Building Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Sheet

AutoCAD SHX Text Notes and/or Revisions:

AutoCAD SHX Text Date

AutoCAD SHX Text

CUSTOM VA FORM 08-6231B, MAY 2012

AutoCAD SHX Text of

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Scale:

AutoCAD SHX Text One inch or not to scale!

AutoCAD SHX Text Approved: VHSO Associate Director

Sheets and Views
564-17-TBD Renovate B21 Basement Restrooms-DEMO PLAN
564-17-TBD Renovate B21 Basement Restrooms-FLOOR PLAN
564-17-TBD Renovate B21 Basement Restrooms-ARCH SCHEDULES
564-17-TBD Renovate B21 Basement Restrooms-PLUMBING PLAN
564-17-TBD Renovate B21 Basement Restrooms-ELECTRICAL PLAN