36C25620B0003-0001003.pdf
PDF Posted
- Solicitation number
- 36C25620B0003
About this file
36C25620B0003 0001 564-17-135_Project Drawings.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25620B0003-0004001.docx | DOCX document | |
| 36C25620B0003-0004000.docx | DOCX document | |
| 36C25620B0003-0003000.docx | DOCX document | |
| 36C25620B0003-0002000.docx | DOCX document | |
| 36C25620B0003-0002001.pdf | ||
| 36C25620B0003-0001004.pdf | ||
| 36C25620B0003-0001001.pdf | ||
| 36C25620B0003-0001002.pdf | ||
| 36C25620B0003-0001000.docx | DOCX document | |
| 36C25620B0003-002.docx | DOCX document | |
| 36C25620B0003-001.docx | DOCX document | |
| 36C25620B0003-003.pdf |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MENS
L230
WOMENS
L231
A Demolition Floor Plan L230-21, L231-21
ETERANS EALTH ARE YSTEMV H C S
OF THE ZARKSO
Engineering Service
1 5
AD100
564-17-TBD
26 JUNE 2017
DEMOLITION FLOOR PLAN
RENOVATE L230, L231 B-21
NTS
VA Healthcare System of the Ozarks
ENG
REMOVE AND STORE EXISTING DOOR FOR MODIFICATION AND
RE-USE. DEMO EXISTING DOOR FRAME FOR REFRAMING
OPENING.
KEY NOTES FOR DEMO PLAN:
DEMO AND DISPOSE OF EXISTING FLOOR COVERING, WALL
MOUNTED CERAMIC TILE, AND BASE IN PREPARATION FOR NEW
RESINOUS EPOXY FLOORING AND INTEGRAL BASE/WALL
COVERING.
DEMO AND DISPOSE OF EXISTING WATER CLOSET PARTITION.
REMOVE EXISTING GRAB BARS AND STORE FOR RELOCATION,
RE-USE.
REMOVE EXISTING WALL HUNG TOILET. PRESERVE AND
PROVIDE TO VHSO ENGINEERING (COR). SEE PLUMBING SHEET
P100 FOR FURTHER PLUMBING DEMO INSTRUCTIONS.
GENERAL NOTES:
1. MEASUREMENTS/LOCATIONS ARE APPROXIMATE AND
SHALL BE VERIFIED BY THE CONTRACTOR. VA WILL NOT
BE RESPONSIBLE FOR ANY ERROR OR VARIATION IN ANY
MEASUREMENTS OR DATA LISTED.
2. APPROPRIATE PPE AND SAFETY PROCEDURES
REQUIRED.
3. ICRA (INFECTION CONTROL RISK ASSESSMENT) WILL BE
PROVIDED BY VHSO PRIOR TO BEGINNING ANY WORK.
ICRA REQUIREMENTS SHALL BE FOLLOWED BY
CONTRACTOR.
4. ALL WORK MUST BE SCHEDULED AND COORDINATED IN
ADVANCE WITH COR.
5. REFER TO SOW AND SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
ICRA DUST/SMOKE BARRIER. PROVIDE/ INSTALL TEMPORARY
ACCESS DOOR WITH KEY PUNCH COMBINATION LOCK SET.
PROVIDE/INSTALL NEGATIVE PRESSURE INDICATOR AT THIS
LOCATION (EQUAL TO BAULIN "BALL IN TUBE").
AutoCAD SHX Text
UP
AutoCAD SHX Text
NTS
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Project Title
AutoCAD SHX Text Date
AutoCAD SHX Text Location
AutoCAD SHX Text Checked
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Drawn
AutoCAD SHX Text Sheet
AutoCAD SHX Text Notes and/or Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
CUSTOM VA FORM 08-6231B, MAY 2012
AutoCAD SHX Text of
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Scale:
AutoCAD SHX Text One inch or not to scale!
AutoCAD SHX Text Approved: VHSO Associate Director
AutoCAD SHX Text Approved: Engineering Service Chief
AutoCAD SHX Text
REVISED PER DESIGN REVIEW MEETING 5/13/16
AutoCAD SHX Text N/A
AutoCAD SHX Text N/A
A New Floor Plan L230-21, L231-21
WOMENS
L231
MENS
L230
ETERANS EALTH ARE YSTEMV H C S
OF THE ZARKSO
Engineering Service
2 5
AE100
564-17-TBD
26 JUNE 2017
NEW FLOOR PLAN
RENOVATE L230, L231 B-21
NTS
VA Healthcare System of the Ozarks
ENG
NEW HEADER AND DOOR FRAME FOR 7'0X3'6" DOOR. EXISTING
DOOR TRIMMED TO FIT NEW FRAME AND RE-INSTALLED WITH
CONTINUOUS HINGE..
KEY NOTES FOR FLOOR PLAN:
NEW ELECTROMECHANICAL DOOR OPERATOR INSTALLED ON
NEW HEADER.
NEW PUSH PLATE WALL MOUNTED DOOR SWITCH (WIRELESS,
BATTERY POWERED) TO ACTIVATE NEW ELECTROMECHANICAL
DOOR OPERATOR. MOUNT TO NEW BACK BOX INSTALLED IN
EXISTING WALLS.
EXISTING GRAB BARS RELOCATED (INSTALL BLOCKING IN
EXISTING WALLS TO SUPPORT).
NEW WATER CLOSET PARTITION AND DOOR. SECURE TO
FLOOR, WALLS, AND STRUCTURE ABOVE CEILING (MODIFY/ADD
TO EXISTING SUPPORTS AS REQUIRED).
GENERAL NOTES:
1. MEASUREMENTS/LOCATIONS ARE APPROXIMATE AND
SHALL BE VERIFIED BY THE CONTRACTOR. VA WILL NOT
BE RESPONSIBLE FOR ANY ERROR OR VARIATION IN ANY
MEASUREMENTS OR DATA LISTED.
2. APPROPRIATE PPE AND SAFETY PROCEDURES
REQUIRED.
3. ICRA (INFECTION CONTROL RISK ASSESSMENT) WILL BE
PROVIDED BY VHSO PRIOR TO BEGINNING ANY WORK.
ICRA REQUIREMENTS SHALL BE FOLLOWED BY
CONTRACTOR.
4. ALL WORK MUST BE SCHEDULED AND COORDINATED IN
ADVANCE WITH COR.
5. REFER TO SOW AND SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
AutoCAD SHX Text
UP
AutoCAD SHX Text
NTS
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Project Title
AutoCAD SHX Text Date
AutoCAD SHX Text Location
AutoCAD SHX Text Checked
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Drawn
AutoCAD SHX Text Sheet
AutoCAD SHX Text Notes and/or Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
CUSTOM VA FORM 08-6231B, MAY 2012
AutoCAD SHX Text of
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Scale:
AutoCAD SHX Text One inch or not to scale!
AutoCAD SHX Text Approved: VHSO Associate Director
AutoCAD SHX Text Approved: Engineering Service Chief
AutoCAD SHX Text
REVISED PER DESIGN REVIEW MEETING 5/13/16
AutoCAD SHX Text N/A
N/A
A New Floor Plan L230-21, L231-21
L231
MENS
L230
DOOR AND FRAME SCHEDULE
ETERANS EALTH ARE YSTEMV H C S
OF THE ZARKSO
Engineering Service
3 5
AE200
564-17-TBD
30 JUNE 2017
FINISHES AND FINISH SCHEDULESRENOVATE L230, L231 B21
VARIES
VA Healthcare System of the Ozarks
ENG
AutoCAD SHX Text
UP
AutoCAD SHX Text
NTS
AutoCAD SHX Text P-01
AutoCAD SHX Text P-02
AutoCAD SHX Text P-01
AutoCAD SHX Text P-02
AutoCAD SHX Text
AT-01
AutoCAD SHX Text
RES-01
AutoCAD SHX Text
AT-01
AutoCAD SHX Text
RES-01
AutoCAD SHX Text
ROOM FINISH SCHEDULE
AutoCAD SHX Text
NAME
AutoCAD SHX Text
MARK
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
BASE
AutoCAD SHX Text
WALLS
AutoCAD SHX Text
TRIM
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
HORIZ MILLWORK
AutoCAD SHX Text
VERT MILLWORK
AutoCAD SHX Text
MENS RESTROOM
AutoCAD SHX Text L230
AutoCAD SHX Text
RES-01
AutoCAD SHX Text P-01
AutoCAD SHX Text P-02
AutoCAD SHX Text
AT-01
AutoCAD SHX Text
WOMENS RESTROOM
AutoCAD SHX Text L231
AutoCAD SHX Text
RES-01
AutoCAD SHX Text P-01
AutoCAD SHX Text P-02
AutoCAD SHX Text
AT-01
AutoCAD SHX Text
RES-01
AutoCAD SHX Text
RES-01
AutoCAD SHX Text
MODIFICATIONS / REMARKS
AutoCAD SHX Text
HDW SET
AutoCAD SHX Text
MATL
AutoCAD SHX Text
DOOR
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
ROOM NO.
AutoCAD SHX Text
RATING (LABEL)
AutoCAD SHX Text
HT
AutoCAD SHX Text
WIDTH
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text L230
AutoCAD SHX Text L231
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
FRAME TYPE
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text
WD
AutoCAD SHX Text
WD
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text 3'-6"
AutoCAD SHX Text
EXISTING DOOR TRIMMED TO 7'0, INSTALL IN NEW FRAME WITH CONTINUOUS SS HINGE
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text 3'-6"
AutoCAD SHX Text
PAIR
AutoCAD SHX Text
EXISTING DOOR TRIMMED TO 7'0, INSTALL IN NEW FRAME WITH CONTINUOUS SS HINGE
AutoCAD SHX Text
MATERIAL TYPE LEGEND
AutoCAD SHX Text
MARK
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
PATTERN / LINE
AutoCAD SHX Text
STYLE
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
COLOR
AutoCAD SHX Text
FINISH
AutoCAD SHX Text
COMMENTS
AutoCAD SHX Text
FLOORING
AutoCAD SHX Text
RESILIENT SHEET FLOORING - SPEC SECTION 09 65 16
AutoCAD SHX Text
RESINOUS FLOORING / INTEGRAL BASE - SPEC SECTION 09 67 23.20
AutoCAD SHX Text
RES-01
AutoCAD SHX Text
TNEMEC
AutoCAD SHX Text
1/8" FLAKE
AutoCAD SHX Text
1C-224-0506 DECO-FLAKE
AutoCAD SHX Text
USE RES-2C-284-0000-DECO-CLEAR
AutoCAD SHX Text
BASE
AutoCAD SHX Text
RUBBER BASE - SPEC SECTION 09 65 13
AutoCAD SHX Text
WALLS
AutoCAD SHX Text
PAINT - SPEC SECTION 09 91 00
AutoCAD SHX Text P-01
AutoCAD SHX Text
*SHERWIN-WILLIAMS
AutoCAD SHX Text
SEMI-GLOSS
AutoCAD SHX Text
USE FOR ALL WALLS AND SOFFITS IN RESTROOMS
AutoCAD SHX Text P-02
AutoCAD SHX Text
*SHERWIN-WILLIAMS
AutoCAD SHX Text
SW6385 DOVER WHITE
AutoCAD SHX Text
GLOSS
AutoCAD SHX Text
CEILINGS
AutoCAD SHX Text
ACOUSTICAL CEILING TILE AND GRID - SPEC SECTION 09 51 00
AutoCAD SHX Text
AT-01
AutoCAD SHX Text
*USG
AutoCAD SHX Text
SANDRIFT CLIMAPLUS
AutoCAD SHX Text
#808 SHADOWLINE
AutoCAD SHX Text 24" x 24" x 3/4"
AutoCAD SHX Text
050 FLAT WHITE
AutoCAD SHX Text
15/16" DONN DX GRID IN WHITE
AutoCAD SHX Text
COUNTERTOPS
AutoCAD SHX Text
SOLID SURFACE - SPEC SECTION 12 36 00
AutoCAD SHX Text
RESINOUS WALL COATINGS - SPEC SECTION 09 67 23.20
AutoCAD SHX Text
RESW-01
AutoCAD SHX Text
TNEMEC
AutoCAD SHX Text
1/4 "FLAKE
AutoCAD SHX Text
1C-224-0506 DECO-FLAKE
AutoCAD SHX Text
GLOSS
AutoCAD SHX Text
USE FOR ALL DOOR TRIM AND CEILINGS
AutoCAD SHX Text
USE RES-2C-284-0000-DECO-CLEAR
AutoCAD SHX Text
*OR EQUAL
AutoCAD SHX Text
PLASTIC LAMINATE - SPEC SECTION 12 36 00
AutoCAD SHX Text
EXISTING TO BE RE-USED
AutoCAD SHX Text N/A
AutoCAD SHX Text N/A
AutoCAD SHX Text N/A
AutoCAD SHX Text
SW 7519 MEXICAN SAND
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Project Title
AutoCAD SHX Text Date
AutoCAD SHX Text Location
AutoCAD SHX Text Checked
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Drawn
AutoCAD SHX Text Sheet
AutoCAD SHX Text Notes and/or Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
CUSTOM VA FORM 08-6231B, MAY 2012
AutoCAD SHX Text of
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Scale:
AutoCAD SHX Text One inch or not to scale!
AutoCAD SHX Text Approved: VHSO Associate Director
Approved: Engineering Service Chief
A New Electrical Plan L230-21, L231-21
L231
MENS
L230
ETERANS EALTH ARE YSTEMV H C S
OF THE ZARKSO
Engineering Service
5 5
EP100
564-17-TBD
30 JUNE 2017
NEW ELECTRICAL RECEPTACLE POWER PLANRENOVATE L230, L231 B21
NTS
VA Healthcare System of the Ozarks
ENG
EXISTING GFCI RECEPTACLES, EXISTING CIRCUIT.
KEY NOTES FOR PLUMBING PLAN:
GENERAL NOTES:
1. MEASUREMENTS/LOCATIONS ARE APPROXIMATE AND
SHALL BE VERIFIED BY THE CONTRACTOR. VA WILL NOT
BE RESPONSIBLE FOR ANY ERROR OR VARIATION IN ANY
MEASUREMENTS OR DATA LISTED.
2. APPROPRIATE PPE AND SAFETY PROCEDURES
REQUIRED.
3. ICRA (INFECTION CONTROL RISK ASSESSMENT) WILL BE
PROVIDED BY VHSO PRIOR TO BEGINNING ANY WORK.
ICRA REQUIREMENTS SHALL BE FOLLOWED BY
CONTRACTOR.
4. ALL WORK MUST BE SCHEDULED AND COORDINATED IN
ADVANCE WITH COR.
5. REFER TO SOW AND SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
NEW HOSPITAL GRADE DUPLEX RECEPTACLE. CONNECT TO
EXISTING CIRCUIT SHOWN. INSTALL IN NEW CUT-IN 2X4 BACK
BOX. COORDINATE HEIGHT AND EXACT LOCATION WITH
AUTOMATIC DOOR OPENER INSTALLER.
NEW WIRELESS, BATTERY OPERATED PUSH PLATES FOR NEW
DOOR OPENERS. BACK BOX FOR PUSH PLATES IN EXISTING
WALLS TO BE INSTALLED BY ELECTRICAL CONTRACTOR.
AutoCAD SHX Text
UP
AutoCAD SHX Text
NTS
AutoCAD SHX Text
GFCI
AutoCAD SHX Text
AutoCAD SHX Text
GFCI
AutoCAD SHX Text
AutoCAD SHX Text
GFCI
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MECHANICAL AND ELECTRICAL SYMBOL LEGEND
AutoCAD SHX Text
DENOTES CONDUIT RUN CONCEALED IN WALL, ABOVE CEILINGS, EXPOSED IN
AutoCAD SHX Text
UNFINISHED AREAS. RUN PARALLEL OR PERPENDICULAR TO STRUCTURE OR WALL.
AutoCAD SHX Text
RECESSED OR SURFACE MOUNTED LIGHTING FIXTURE CONNECTED TO NORMAL
AutoCAD SHX Text
BRANCH CIRCUIT. SEE LIGHTING FIXTURE SCHEDULE FOR EXACT REQUIREMENTS.
AutoCAD SHX Text
RECESSED OR SURFACE MOUNTED LIGHTING FIXTURE CONNECTED TO LIFE SAFETY BRANCH
AutoCAD SHX Text
CIRCUIT FOR PROJECTS W/ GENERATOR OR PROVIDE LOCAL BATTERY PACK W/O GEN.
AutoCAD SHX Text
SEE LIGHTING FIXTURE SCHEDULE FOR EXACT REQUIREMENTS. LETTER INDICATES TYPE.
AutoCAD SHX Text
CEILING MOUNTED EXIT SIGN, SHADED AREA INDICATES FACE WITH DIRECTIONAL ARROWS AS
AutoCAD SHX Text
SHOWN. SEE LTG. FIXT. SCHEDULE FOR EXACT REQUIREMENTS. CONNECT TO UNSWITCHED
AutoCAD SHX Text
BRANCH CKT. INDICATED ON DWGS. SUBSCRIPT "WG" WHEN INDICATED DENOTES WIREGUARD.
AutoCAD SHX Text S
AutoCAD SHX Text
SINGLE-POLE, 20 AMP, 120/277 VOLT, TOGGLE SWITCH IN FLUSH (FINISHED SPACES)
AutoCAD SHX Text
OR SURFACE (UNFINISHED SPACES) OUTLET BOX. MOUNT 44" A.F.F. UNLESS
AutoCAD SHX Text
OTHERWISE INDICATED.
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text
SINGLE POLE, 20 AMP, 120/277 VOLT, SWITCH CONNECTED TO EMERGENCY BRANCH CKT.
AutoCAD SHX Text
PROVIDE RED SWITCH. MOUNT IN FLUSH (FINISHED SPACES) OR SURFACE (UNFINISHED
AutoCAD SHX Text
SPACES) OUTLET BOX. MOUNT 44" A.F.F. UNLESS OTHERWISE INDICATED.
AutoCAD SHX Text
20 AMP, 125 VOLT, 3 WIRE DUPLEX RECEPTACLE IN FLUSH (FINISHED SPACES) OR SURFACE
AutoCAD SHX Text
(UNFINISHED SPACES) OUTLET BOX. MOUNT 18" A.F.F. UNLESS OTHERWISE INDICATED.
AutoCAD SHX Text
20 AMP, 125 VOLT, 3 WIRE DUPLEX RECEPTACLE IN FLUSH (FINISHED SPACES) OR SURFACE
AutoCAD SHX Text
(UNFINISHED SPACES) OUTLET BOX. MOUNT 44" ABOVE FINISHED FLOOR, 4" ABOVE DESK/
AutoCAD SHX Text
COUNTERTOP, OR 2" ABOVE BACKSPLASH UNLESS OTHERWISE INDICATED.
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
20 AMP, 125 VOLT, 3 WIRE DUPLEX RECEPTACLE CONNECTED TO EMERGENCY BRANCH
AutoCAD SHX Text
CIRCUIT. PROVIDE RED RECEPTACLE AND ENGRAVED CIRCUIT DESIGNATION NAMEPLATE
AutoCAD SHX Text
UNLESS OTHERWISE INDICATED.
AutoCAD SHX Text
GF
AutoCAD SHX Text
GF
AutoCAD SHX Text
GF
AutoCAD SHX Text
GF
AutoCAD SHX Text
20 AMP, 125 VOLT, 3 WIRE GROUND FAULT TYPE DUPLEX RECEPTACLE(S).
AutoCAD SHX Text
MOUNTING AS INDICATED.
AutoCAD SHX Text
CR
AutoCAD SHX Text
SECURITY SYSTEM CARD READER FLUSH MOUNTED 44" A.F.F. UNLESS OTHERWISE INDICATED.
AutoCAD SHX Text S
AutoCAD SHX Text
INTERCOM/SOUND SYSTEM FLUSH MOUNTED CEILING SPEAKER.
AutoCAD SHX Text
FIRE ALARM INTERCOM/SOUND SYSTEM FLUSH MOUNTED CEILING SPEAKER.
AutoCAD SHX Text F
AutoCAD SHX Text
SUPPLY AIR DIFFUSER
AutoCAD SHX Text
RETURN AIR DIFFUSER
AutoCAD SHX Text T
AutoCAD SHX Text
ROOM CONTROL THERMOSTAT; WALL MOUNTED TOP OF THERMOSTAT AT 48" AFF
AutoCAD SHX Text
TWO 20 AMP, 125 VOLT, 3 WIRE RECEPTACLES IN FLUSH (FINISHED SPACES) OR
AutoCAD SHX Text SURFACE (UNFINISHED SPACES) 2-GANG OUTLET BOX SINGLE YOKE. MOUNT 18" A.F.F. UNLESS
AutoCAD SHX Text
OTHERWISE INDICATED.
AutoCAD SHX Text
TELECOMMUNICATIONS OUTLET MOUNTED 18" GAFF U.O.I. SUBSCRIPT 'XD' AND/OR 'XV' AND
AutoCAD SHX Text
/OR 'XF', WHEN SHOWN, DENOTES NUMBER OF DATA AND/OR VOICE CABLES AND/OR FIBERS
AutoCAD SHX Text
AND JACKS RESPECTIVELY. SUBSCRIPT "WT" DENOTES WIRELESS TRANSMITTER.
AutoCAD SHX Text C
AutoCAD SHX Text
DENOTES CEILING MOUNTED
AutoCAD SHX Text
SUSPENDED ACOUSTICAL CEILING
AutoCAD SHX Text
SUSPENDED GWB
AutoCAD SHX Text R
AutoCAD SHX Text
SURFACE LIGHTING FIXTURE CONNECTED TO NORMAL
AutoCAD SHX Text
BRANCH CIRCUIT. SEE LIGHTING FIXTURE SCHEDULE FOR EXACT REQUIREMENTS.
AutoCAD SHX Text
RECESSED CAN LIGHTING FIXTURE CONNECTED TO NORMAL
AutoCAD SHX Text
BRANCH CIRCUIT. SEE LIGHTING FIXTURE SCHEDULE FOR EXACT REQUIREMENTS.
AutoCAD SHX Text S
AutoCAD SHX Text D
AutoCAD SHX Text
SINGLE-POLE, 20 AMP, 120/277 VOLT, DIMMER SWITCH IN FLUSH (FINISHED SPACES)
AutoCAD SHX Text
OR SURFACE (UNFINISHED SPACES) OUTLET BOX. MOUNT 44" A.F.F. UNLESS
AutoCAD SHX Text
OTHERWISE INDICATED. DIMMER SWITCH MUST BE COMPATIBLE WITH FIXTURE.
AutoCAD SHX Text
TELECOMMUNICATIONS OUTLET CEILING MOUNTED U.O.I. SUBSCRIPT 'XD' AND/OR 'XV' AND
AutoCAD SHX Text
/OR 'XF', WHEN SHOWN, DENOTES NUMBER OF DATA AND/OR VOICE CABLES AND/OR FIBERS
AutoCAD SHX Text
AND JACKS RESPECTIVELY. EXACT LOCATION TO BE DETERMINED BY COR.
AutoCAD SHX Text
WALL MOUNTED TELEPHONE JACK. LOCATED 44" AFF.
AutoCAD SHX Text CABLE TELEVISION OUTLET. REMOVE OLD TV CABLES AND REPLACE WITH NEW TO MATCH EXISTING SYSTEM.
AutoCAD SHX Text
TV
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Project Title
AutoCAD SHX Text Date
AutoCAD SHX Text Location
AutoCAD SHX Text Checked
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Drawn
AutoCAD SHX Text Sheet
AutoCAD SHX Text Notes and/or Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
CUSTOM VA FORM 08-6231B, MAY 2012
AutoCAD SHX Text of
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Scale:
AutoCAD SHX Text One inch or not to scale!
AutoCAD SHX Text Approved: VHSO Associate Director
A Plumbing Demolition Plan L231-21
ETERANS EALTH ARE YSTEMV H C S
OF THE ZARKSO
Engineering Service
4 5 P100
564-17-TBD
30 JUNE 2017
PLUMBING DEMOLITION PLANRENOVATE L230, L231 B21
NTS
VA Healthcare System of the Ozarks
ENG
TOILET TO BE DEMO'D AND REMOVED. CAP COLD WATER LINE
AT TEE FROM BRANCH. CAP SANITARY INSIDE EXISTING WALL.
INSTALL 8"X8" ACCESS PANEL AT SANITARY CAP LOCATION.
KEY NOTES FOR PLUMBING PLAN:
GENERAL NOTES:
1. MEASUREMENTS/LOCATIONS ARE APPROXIMATE AND
SHALL BE VERIFIED BY THE CONTRACTOR. VA WILL NOT
BE RESPONSIBLE FOR ANY ERROR OR VARIATION IN ANY
MEASUREMENTS OR DATA LISTED.
2. APPROPRIATE PPE AND SAFETY PROCEDURES
REQUIRED.
3. ICRA (INFECTION CONTROL RISK ASSESSMENT) WILL BE
PROVIDED BY VHSO PRIOR TO BEGINNING ANY WORK.
ICRA REQUIREMENTS SHALL BE FOLLOWED BY
CONTRACTOR.
4. ALL WORK MUST BE SCHEDULED AND COORDINATED IN
ADVANCE WITH COR.
5. REFER TO SOW AND SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
AutoCAD SHX Text
UP
AutoCAD SHX Text
LOBBY
AutoCAD SHX Text C-L001
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C-L002
AutoCAD SHX Text
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text 21-L231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MEN
AutoCAD SHX Text 21-L230
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text C-L004
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
STAIR 1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text P-1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text P-2
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text P-3
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PF-300
AutoCAD SHX Text P-421
AutoCAD SHX Text P-103
AutoCAD SHX Text P-103
AutoCAD SHX Text P-103
AutoCAD SHX Text P-421
AutoCAD SHX Text P-202
AutoCAD SHX Text P-609
AutoCAD SHX Text
1" HWR UP
AutoCAD SHX Text
2" HW UP
AutoCAD SHX Text
2 1/2" CW UP
AutoCAD SHX Text
6" ST UP
AutoCAD SHX Text (2168 )
AutoCAD SHX Text
6" ERD UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
LOBBY
AutoCAD SHX Text C-L001
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C-L002
AutoCAD SHX Text
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text 21-L231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MEN
AutoCAD SHX Text 21-L230
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text C-L004
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
STAIR 1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text P-1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text P-2
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text P-3
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NTS
AutoCAD SHX Text
MECHANICAL AND ELECTRICAL SYMBOL LEGEND
AutoCAD SHX Text
DENOTES CONDUIT RUN CONCEALED IN WALL, ABOVE CEILINGS, EXPOSED IN
AutoCAD SHX Text
UNFINISHED AREAS. RUN PARALLEL OR PERPENDICULAR TO STRUCTURE OR WALL.
AutoCAD SHX Text
RECESSED OR SURFACE MOUNTED LIGHTING FIXTURE CONNECTED TO NORMAL
AutoCAD SHX Text
BRANCH CIRCUIT. SEE LIGHTING FIXTURE SCHEDULE FOR EXACT REQUIREMENTS.
AutoCAD SHX Text
RECESSED OR SURFACE MOUNTED LIGHTING FIXTURE CONNECTED TO LIFE SAFETY BRANCH
AutoCAD SHX Text
CIRCUIT FOR PROJECTS W/ GENERATOR OR PROVIDE LOCAL BATTERY PACK W/O GEN.
AutoCAD SHX Text
SEE LIGHTING FIXTURE SCHEDULE FOR EXACT REQUIREMENTS. LETTER INDICATES TYPE.
AutoCAD SHX Text
CEILING MOUNTED EXIT SIGN, SHADED AREA INDICATES FACE WITH DIRECTIONAL ARROWS AS
AutoCAD SHX Text
SHOWN. SEE LTG. FIXT. SCHEDULE FOR EXACT REQUIREMENTS. CONNECT TO UNSWITCHED
AutoCAD SHX Text
BRANCH CKT. INDICATED ON DWGS. SUBSCRIPT "WG" WHEN INDICATED DENOTES WIREGUARD.
AutoCAD SHX Text S
AutoCAD SHX Text
SINGLE-POLE, 20 AMP, 120/277 VOLT, TOGGLE SWITCH IN FLUSH (FINISHED SPACES)
AutoCAD SHX Text
OR SURFACE (UNFINISHED SPACES) OUTLET BOX. MOUNT 44" A.F.F. UNLESS
AutoCAD SHX Text
OTHERWISE INDICATED.
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text
SINGLE POLE, 20 AMP, 120/277 VOLT, SWITCH CONNECTED TO EMERGENCY BRANCH CKT.
AutoCAD SHX Text
PROVIDE RED SWITCH. MOUNT IN FLUSH (FINISHED SPACES) OR SURFACE (UNFINISHED
AutoCAD SHX Text
SPACES) OUTLET BOX. MOUNT 44" A.F.F. UNLESS OTHERWISE INDICATED.
AutoCAD SHX Text
20 AMP, 125 VOLT, 3 WIRE DUPLEX RECEPTACLE IN FLUSH (FINISHED SPACES) OR SURFACE
AutoCAD SHX Text
(UNFINISHED SPACES) OUTLET BOX. MOUNT 18" A.F.F. UNLESS OTHERWISE INDICATED.
AutoCAD SHX Text
20 AMP, 125 VOLT, 3 WIRE DUPLEX RECEPTACLE IN FLUSH (FINISHED SPACES) OR SURFACE
AutoCAD SHX Text
(UNFINISHED SPACES) OUTLET BOX. MOUNT 44" ABOVE FINISHED FLOOR, 4" ABOVE DESK/
AutoCAD SHX Text
COUNTERTOP, OR 2" ABOVE BACKSPLASH UNLESS OTHERWISE INDICATED.
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
20 AMP, 125 VOLT, 3 WIRE DUPLEX RECEPTACLE CONNECTED TO EMERGENCY BRANCH
AutoCAD SHX Text
CIRCUIT. PROVIDE RED RECEPTACLE AND ENGRAVED CIRCUIT DESIGNATION NAMEPLATE
AutoCAD SHX Text
UNLESS OTHERWISE INDICATED.
AutoCAD SHX Text
GF
AutoCAD SHX Text
GF
AutoCAD SHX Text
GF
AutoCAD SHX Text
GF
AutoCAD SHX Text
20 AMP, 125 VOLT, 3 WIRE GROUND FAULT TYPE DUPLEX RECEPTACLE(S).
AutoCAD SHX Text
MOUNTING AS INDICATED.
AutoCAD SHX Text
CR
AutoCAD SHX Text
SECURITY SYSTEM CARD READER FLUSH MOUNTED 44" A.F.F. UNLESS OTHERWISE INDICATED.
AutoCAD SHX Text S
AutoCAD SHX Text
INTERCOM/SOUND SYSTEM FLUSH MOUNTED CEILING SPEAKER.
AutoCAD SHX Text
FIRE ALARM INTERCOM/SOUND SYSTEM FLUSH MOUNTED CEILING SPEAKER.
AutoCAD SHX Text F
AutoCAD SHX Text
SUPPLY AIR DIFFUSER
AutoCAD SHX Text
RETURN AIR DIFFUSER
AutoCAD SHX Text T
AutoCAD SHX Text
ROOM CONTROL THERMOSTAT; WALL MOUNTED TOP OF THERMOSTAT AT 48" AFF
AutoCAD SHX Text
TWO 20 AMP, 125 VOLT, 3 WIRE RECEPTACLES IN FLUSH (FINISHED SPACES) OR
AutoCAD SHX Text SURFACE (UNFINISHED SPACES) 2-GANG OUTLET BOX SINGLE YOKE. MOUNT 18" A.F.F. UNLESS
AutoCAD SHX Text
OTHERWISE INDICATED.
AutoCAD SHX Text
TELECOMMUNICATIONS OUTLET MOUNTED 18" GAFF U.O.I. SUBSCRIPT 'XD' AND/OR 'XV' AND
AutoCAD SHX Text
/OR 'XF', WHEN SHOWN, DENOTES NUMBER OF DATA AND/OR VOICE CABLES AND/OR FIBERS
AutoCAD SHX Text
AND JACKS RESPECTIVELY. SUBSCRIPT "WT" DENOTES WIRELESS TRANSMITTER.
AutoCAD SHX Text C
AutoCAD SHX Text
DENOTES CEILING MOUNTED
AutoCAD SHX Text
SUSPENDED ACOUSTICAL CEILING
AutoCAD SHX Text
SUSPENDED GWB
AutoCAD SHX Text R
AutoCAD SHX Text
SURFACE LIGHTING FIXTURE CONNECTED TO NORMAL
AutoCAD SHX Text
BRANCH CIRCUIT. SEE LIGHTING FIXTURE SCHEDULE FOR EXACT REQUIREMENTS.
AutoCAD SHX Text
RECESSED CAN LIGHTING FIXTURE CONNECTED TO NORMAL
AutoCAD SHX Text
BRANCH CIRCUIT. SEE LIGHTING FIXTURE SCHEDULE FOR EXACT REQUIREMENTS.
AutoCAD SHX Text S
AutoCAD SHX Text D
AutoCAD SHX Text
SINGLE-POLE, 20 AMP, 120/277 VOLT, DIMMER SWITCH IN FLUSH (FINISHED SPACES)
AutoCAD SHX Text
OR SURFACE (UNFINISHED SPACES) OUTLET BOX. MOUNT 44" A.F.F. UNLESS
AutoCAD SHX Text
OTHERWISE INDICATED. DIMMER SWITCH MUST BE COMPATIBLE WITH FIXTURE.
AutoCAD SHX Text
TELECOMMUNICATIONS OUTLET CEILING MOUNTED U.O.I. SUBSCRIPT 'XD' AND/OR 'XV' AND
AutoCAD SHX Text
/OR 'XF', WHEN SHOWN, DENOTES NUMBER OF DATA AND/OR VOICE CABLES AND/OR FIBERS
AutoCAD SHX Text
AND JACKS RESPECTIVELY. EXACT LOCATION TO BE DETERMINED BY COR.
AutoCAD SHX Text
WALL MOUNTED TELEPHONE JACK. LOCATED 44" AFF.
AutoCAD SHX Text CABLE TELEVISION OUTLET. REMOVE OLD TV CABLES AND REPLACE WITH NEW TO MATCH EXISTING SYSTEM.
AutoCAD SHX Text
TV
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Project Title
AutoCAD SHX Text Date
AutoCAD SHX Text Location
AutoCAD SHX Text Checked
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Drawn
AutoCAD SHX Text Sheet
AutoCAD SHX Text Notes and/or Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
CUSTOM VA FORM 08-6231B, MAY 2012
AutoCAD SHX Text of
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Scale:
AutoCAD SHX Text One inch or not to scale!
AutoCAD SHX Text Approved: VHSO Associate Director
| AD100 DEMO PLAN |
| Sheets and Views |
| DEMO PLAN |
| AE100 FLOOR PLAN |
| Sheets and Views |
| FLOOR PLAN |
| AE200 FINISHES |
| Sheets and Views |
| ARCH SCHEDULES |
| EP100 ELECTRICAL PLAN |
| Sheets and Views |
| ELECTRICAL PLAN |
| P100 PLUMBING DEMO |
| Sheets and Views |
| PLUMBING PLAN |