36C25619R0073-009.pdf
PDF 13 MB Posted
- Attached to
- 580-320 Construct Spinal Cord Injury Expansion Federal contract opportunity
- Solicitation number
- 36C25619R0073
About this file
36C25619R0073 ATTACHMENT H - Project Drawings Part 5 - Dated 6-8-18 - 2 pages.pdf
View the file
Other files for this federal contract opportunity
Show all 50
580-320 Construct Spinal Cord Injury Expansion has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
6565 West Loop South, Suite 560, Bellaire, TX 77401
713.432.1422 - Fax 713.432.1253 www.garnerfritsche.com th re e i n c h e s o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -e ig h ts i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t o n e -e ig h t in c h o n e f o o t
0 Revisions:
IS
S
U E
D F
O R
B
ID
D
IN
G
C O
N S
TR
U
C
TI
O N
Drawing Number
DrawnChecked
Dwg. of Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
VA FORM 08-6231
Atriax, pllc 102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architectural License No.: 51254
Drawing Title
Approved: Project Director
Project Title
Location
Date
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Building Number
B100
Project Number
Office of
Construction and Facilities
Management
V eterans Affairs P alo Alto Heal th Ca re Sy stem
S cale: 1 "= 20'-0"S cale: 1-1 /2"= 1'-0"S cale: 1"= 1'-0"S cale: 3/ 32"= 1'-0"S cale: 1/ 16"= 1'-0"S cale: 3/ 16"= 1'-0"S cale: 3/ 4"= 1'-0"S cale: 3/ 8"= 1'-0"S cale: 1/ 2"= 1'-0"S cale: 1/ 4"= 1'-0"
AV P AHC SV eterans Affairs P alo Alto Heal th Ca re Sy stem
D ESIGN DEVE LO PM ENT - NO T FO R CO NSTRUCTIO NF ULLY SPR INKL ERED
T exas Reg. No.G FE Project No.F-571213060
Issued for Bidding & Construction 06/08/18
FOR REFERENCE ONLY
212AuthorChecker06/08/18
GI-211
AS BUILT INFORMATION - DETAILS CONSTRUCT SPINAL CORD
INJURY BED EXPANSION
2002 HOLCOMBE BLVD, HOUSTON, TX 77030
#580 - 320
N.T.S.
AS-BUILT
WALL SECTION 1-289
F9
0' 1' 2'6" 3/4" = 1'-0"
AS-BUILT SLAB
DETAIL 10/S172
C4
0' 1'6" 1" = 1'-0"
AS-BUILT COLUMN
DETAIL 7/323
F1 0' 1' 2'6"
3/4" = 1'-0"
AS-BUILT SECTION
DETAIL 6/289
F7
0' 1' 2'6" 3/4" = 1'-0"
AS-BUILT SECTION
DETAIL 5/289
D7
0' 1'6" 1" = 1'-0"
AS-BUILT COLUMN
DETAIL 4/323
F3
NOTE: INFORMATION SHOWN THIS SHEET IS AN EXCERPT FROM THE
ORIGINAL CONSTRUCTION DRAWINGS TO ASSIST THE CONTRACTOR
WITH EXISTING EXTERIOR WALL AND CURTAIN WALL CONSTRUCTION
WHERE REMOVAL OF SAME PROVIDES ACCESS FOR ADDITION
CONSTRUCTION. THIS INFORMATION HAS NOT BEEN VERIFIED AND IS
PROVIDED AS INFORMATION ONLY FOR CONTRACTOR USE AT THEIR
DISCRETION AND RISK.
6565 West Loop South, Suite 560, Bellaire, TX 77401
713.432.1422 - Fax 713.432.1253 www.garnerfritsche.com th re e i n c h e s o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -e ig h ts i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t o n e -e ig h t in c h o n e f o o t
0 Revisions:
IS
S
U E
D F
O R
B
ID
D
IN
G
C O
N S
TR
U
C
TI
O N
Drawing Number
DrawnChecked
Dwg. of Date:
CONSULTANTS: ARCHITECT/ENGINEERS:
VA FORM 08-6231
Atriax, pllc 102 3rd Avenue, NE PO Box 1629, Hickory, NC 28603 T: 828.315.9962 F: 828.315.9964 www.atriaxgroup.com NC Engineering License No.: P-0214 NC Architectural License No.: 51254
Drawing Title
Approved: Project Director
Project Title
Location
Date
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Building Number
B100
Project Number
Office of
Construction and Facilities
Management
V eterans Affairs P alo Alto Heal th Ca re Sy stem
S cale: 1 "= 20'-0"S cale: 1-1 /2"= 1'-0"S cale: 1"= 1'-0"S cale: 3/ 32"= 1'-0"S cale: 1/ 16"= 1'-0"S cale: 3/ 16"= 1'-0"S cale: 3/ 4"= 1'-0"S cale: 3/ 8"= 1'-0"S cale: 1/ 2"= 1'-0"S cale: 1/ 4"= 1'-0"
AV P AHC SV eterans Affairs P alo Alto Heal th Ca re Sy stem
D ESIGN DEVE LO PM ENT - NO T FO R CO NSTRUCTIO NF ULLY SPR INKL ERED
T exas Reg. No.G FE Project No.F-571213060
Issued for Bidding & Construction 06/08/18
FOR REFERENCE ONLY
212AuthorChecker06/08/18
GI-212
AS BUILT INFORMATION - DETAILS CONSTRUCT SPINAL CORD
INJURY BED EXPANSION
2002 HOLCOMBE BLVD, HOUSTON, TX 77030
#580 - 320
0' 6"3" 1'9" 1 1/2" = 1'-0"
AS-BUILT SECTION
DETAIL 14/L-113
D1
0' 4' 6'2' 1/4" = 1'-0"
AS-BUILT
ELARGED PLAN 2/L-112
F60' 6"3" 1'9"
1 1/2" = 1'-0"
AS-BUILT SECTION
DETAIL 15/L-113
F1 0' 1' 2'6"
3/4" = 1'-0"
AS-BUILT PLANTER
DETAIL 12/S174
F4
0' 2' 3'1' 1/2" = 1'-0"
AS-BUILT PLANTER
SECTION 1/302
B6
NOTE: INFORMATION SHOWN THIS SHEET IS AN EXCERPT FROM THE
ORIGINAL CONSTRUCTION DRAWINGS TO ASSIST THE CONTRACTOR
WITH EXISTING EXTERIOR WALL AND CURTAIN WALL CONSTRUCTION
WHERE REMOVAL OF SAME PROVIDES ACCESS FOR ADDITION
CONSTRUCTION. THIS INFORMATION HAS NOT BEEN VERIFIED AND IS
PROVIDED AS INFORMATION ONLY FOR CONTRACTOR USE AT THEIR
DISCRETION AND RISK.
0' 2"1" 6"3" 3" = 1'-0"
AS-BUILT
PAVING DETAIL 2, 3, 4 & 5/S-308
C4