S06 - Spec 06 20 00.pdf
PDF 699 KB Posted
- Solicitation number
- 36C25221B0018
About this file
This document contains a specification section and a federal contract opportunity notice. The specification section outlines requirements for finish carpentry work including materials, submittals, quality assurance, delivery and handling, field conditions, warranties, and execution. Key materials specified include lumber, plywood, particleboard, plastic laminate, and accessories.
The federal contract opportunity notice is for project 607-19-101 to relocate a pharmacy compounding area at the William S. Middleton Memorial Veterans Hospital in Madison, Wisconsin. The project scope involves renovations to approximately 3,100 square feet and includes phasing, demolition, hazardous material removal, carpentry, interior finishes, windows and doors, plumbing, HVAC, electrical, and communications systems work. The solicitation will be issued on or about June 17, 2021 with bids due on or about July 21, 2021. The project value is estimated between $1-2 million. The NAICS code is 236220 with a $39.5 million size standard. The period of performance is 395 calendar days after notice to proceed. The opportunity is set aside for service-disabled veteran-owned small businesses.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25221B0018 0002.docx | DOCX document | |
| S06 - SF 1442 - Revised.pdf | ||
| S06 - Wage Determination Revised.pdf | ||
| S06 - A751 Pharmacy.pdf | ||
| S06 - Pre-Bid Attendance List.pdf | ||
| S06 - Spec 12 36 00.pdf | ||
| 36C25221B0018 0001.docx | DOCX document | |
| S02 - Project 607-19-101 - Volume 1 Drawings.pdf | ||
| S02 - Project 607-19-101 - Volume 2 Specifications.pdf | ||
| Wage Determination.pdf | ||
| S02 - Project 607-19-101 - Volume 1 Specifications.pdf | ||
| 36C25221B0018_1.docx | DOCX document | |
| S02 - Project 607-19-101 - Volume 2 Drawings.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
01-01-21
06 20 00 - 1
SECTION 06 20 00
FINISH CARPENTRY
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1.2 RELATED REQUIREMENTS
A. Adhesive, Paint, and Finish VOC Limits: Section 01 81 13, SUSTAINABLE
CONSTRUCTION REQUIREMENTS.
B. .
C. Framing, furring and blocking: Section 06 10 00, ROUGH CARPENTRY.
D. ELECTRICAL.
1.3 APPLICABLE PUBLICATIONS
A. Comply with references to extent specified in this section.
B. ASTM International:
A36/A36M-19.............Carbon Structural Steel.
A53/A53M-20.............Pipe, Steel, Black and Hot-Dipped Zinc Coated, Welded and Seamless.
A240/A240M-20...........Chromium and Chromium-Nickel Stainless Steel
Plate, Sheet, and Strip for Pressure Vessels and for General Applications.
B26/B26M-18e1...........Aluminum-Alloy Sand Castings.
B221-14.................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes.
E84-20..................Surface Burning Characteristics of Building
Materials.
C. American Hardboard Association (AHA):
A135.4-12...............Basic Hardboard.
D. Architectural Woodwork Institute (AWI):
AWI-14..................Architectural Woodwork Standards, 2nd ed.
E. Builders Hardware Manufacturers Association (BHMA):
A156.9-15...............Cabinet Hardware.
A156.11-14..............Cabinet Locks.
A156.16-18..............Auxiliary Hardware.
F. Federal Specifications (Fed. Spec.):
A-A-1922A...............Shield Expansion (Calking Anchors, Single
Lead).
"ACCOMPANYING AMENDMENT 36C25221B0018 - 0001"
06 20 00 - 2
A-A-1936A...............Adhesive, Contact, Neoprene Rubber.
FF-N-836E...............Nut: Square, Hexagon, Cap, Slotted, Castle, Knurled, Welding.
FF-S-111D(1)............Screw, Wood (Notice 1 inactive for new design).
MM-L-736C(1)............Lumber, Hardwood.
G. Hardwood Plywood and Veneer Association (HPVA):
HP1-16..................Hardwood and Decorative Plywood.
H. Military Specification (Mil. Spec):
MIL-L-19140E............Lumber and Plywood, Fire-Retardant Treated.
I. National Particleboard Association (NPA):
A208.1-09...............Wood Particleboard.
J. National Electrical Manufacturers Association (NEMA):
LD 3-05.................High-Pressure Decorative Laminates.
K. U.S. Department of Commerce, Product Standard (PS):
PS1-07..................Construction and Industrial Plywood.
PS20-10.................American Softwood Lumber Standard.
1.4 PREINSTALLATION MEETINGS
A. Conduct pre-installation meeting at project site minimum 30 days before beginning Work of this section.
1. Required Participants:
a. Contracting Officer's Representative.
b. VA Interior Designer.
c. Contractor.
d. Installer.
2. Meeting Agenda: Distribute agenda to participants minimum 3 days before meeting.
a. Installation schedule.
b. Installation sequence.
c. Preparatory work.
d. Protection before, during, and after installation.
e. Installation.
f. Terminations.
g. Transitions and connections to other work.
h. Other items affecting successful completion.
3. Document and distribute meeting minutes to participants to record decisions affecting installation.
06 20 00 - 3
1.5 SUBMITTALS
A. Submittal Procedures: Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.
B. Submittal Drawings:
1. Show size, configuration, and fabrication and installation details.
2. Millwork items - Half full-size scale for sections and details 1: 50
(1/4 inch) for elevations and plans.
C. Manufacturer's Literature and Data:
1. Description of each product.
a. Finish hardware.
b. Sinks with fittings.
2. List of acceptable sealers for fire retardant materials.
3. Installation instructions.
D. Samples:
1. Plastic Laminate Finished Plywood and Particleboard: 150 mm by
300 mm (6 by 12 inches) long, each type and color .
a. Submit quantity required to show full color and texture range.
2. Approved samples may be incorporated into work.
E. Certificates: Certify products comply with specifications.
1. Fire retardant treatment of materials.
2. Moisture content of materials.
F. Qualifications: Substantiate qualifications comply with specifications.
1. Fabricator with project experience list.
2. Installer with project experience list.
1.6 QUALITY ASSURANCE
A. Fabricator Qualifications:
1. Regularly fabricates specified products.
2. Fabricated specified products with satisfactory service on five similar installations for minimum five years.
a. Project Experience List: Provide contact names and addresses for completed projects.
B. Installer Qualifications:
1. Regularly installs specified products.
2. Installed specified products with satisfactory service on five similar installations for minimum five years.
a. Project Experience List: Provide contact names and addresses for completed projects.
06 20 00 - 4
1.7 DELIVERY, STORAGE AND HANDLING
A. Deliver products in manufacturer's original sealed packaging.
B. Mark packaging, legibly. Indicate manufacturer's name or brand, type, color, production run number, and manufacture date.
C. Before installation, return or dispose of products within distorted, damaged, or opened packaging.
D. Store products indoors in dry, weathertight conditioned facility.
E. Protect products from damage during handling and construction operations.
1.8 FIELD CONDITIONS
A. Environment:
1. Product Temperature: Minimum 21 degrees C (70 degrees F) for minimum
48 hours before installation.
2. Work Area Ambient Conditions: HVAC systems are complete, operational, and maintaining facility design operating conditions continuously, beginning 48 hours before installation until
Government occupancy.
3. Install products when building is permanently enclosed and when wet construction is completed, dried, and cured.
4. Do not install finish lumber or millwork in any room or space where wet process systems such as concrete, masonry, or plaster work is not complete and dry.
B. Field Measurements: Verify field conditions affecting fabrication and installation.
1. Coordinate field measurement and fabrication schedule to avoid delay.
1.9 WARRANTY
A. Construction Warranty: FAR clause 52.246-21, "Warranty of
Construction."
PART 2 - PRODUCTS
2.1 MATERIALS
A. Grading and Marking: Factory mark with grade stamp lumber and plywood of inspection agency approved by the Board of Review, American Lumber
Standard Committee.
B. Lumber:
1. Sizes:
06 20 00 - 5
a. Lumber Size references, unless otherwise specified, are nominal sizes, and actual sizes within manufacturing tolerances allowed by the standard under which product is produced.
b. Millwork, standing and running trim, and rails: Actual size as shown or specified.
2. Hardwood: MM-L-736, species as specified for each item.
3. Softwood: PS-20, exposed to view appearance grades:
a. Use C select or D select, vertical grain for transparent finish including stain transparent finish.
b. Use Prime for painted or opaque finish.
4. Use edge grain Wood members exposed to weather.
5. Moisture Content:
a. 32 mm (1-1/4 inches) or less nominal thickness: 12 percent on 85 percent of the pieces and 15 percent on the remainder.
b. Other materials: According to standards under which the products are produced.
6. Fire Retardant Treatment: Mil. Spec. MIL-L-19140E.
a. Treatment and performance inspection by an independent and qualified testing agency that establishes performance ratings.
b. Each piece of treated material bear identification of the testing agency and indicate performance according to such rating of flame spread and smoke developed.
c. Treat wood for maximum flame spread of 25 and smoke developed of
25.
d. Fire Resistant Softwood Plywood:
1) Grade A, Exterior, plywood for treatment.
2) Surface Burning Characteristics: When tested according to
ASTM E84.
a) Flame spread: 0 to 25.
b) Smoke developed: 100 maximum.
e. Fire Resistant Hardwood Plywood:
1) Core: Fire retardant treated softwood plywood.
2) Hardwood face and back veneers untreated.
3) Factory seal panel edges.
C. Plywood:
1. Softwood Plywood: DOC PS1.
06 20 00 - 6
a. Plywood, 13 mm (1/2 inch) and thicker; minimum five ply construction, except 32 mm (1-1/4 inch) thick plywood minimum seven ply.
b. Plastic Laminate Plywood Cores:
1) Exterior Type, and species group.
2) Veneer Grade: A-C.
c. Shelving Plywood:
1) Interior Type, any species group.
2) Veneer Grade: A-B or B-C.
d. Other: As specified for item.
2. Hardwood Plywood: HPVA: HP.1.
a. Species of Face Veneer: As shown or as specified with each particular item.
b. Grade:
1) Transparent Finish: Type II (interior) A grade veneer.
2) Paint Finish: Type II (interior) Sound Grade veneer.
c. Species and Cut: Plain sliced red oak unless specified otherwise.
D. Particleboard: NPA A208.1, Type 1, Grade 1-M-3.
1. Plastic Laminate Particleboard Cores:
a. Type 1, Grade 1-M-3, unless otherwise specified.
b.
E. Plastic Laminate: NEMA LD-3.
1. Exposed Laminate Surfaces, and Sides of Cabinet Doors: Grade HGL.
2. Cabinet Interiors including Shelving: NEMA, CLS as a minimum, with the following:
a. Plastic laminate clad plywood or particle board.
2.2 PRODUCTS - GENERAL
A. Provide each product from one manufacturer and from one production run .
2.3 FABRICATION
A. General:
1. AWI Custom Grade for interior millwork.
2. Finish woodwork, free from pitch pockets.
3. Plastic Laminate Work:
a. Factory glued to either a plywood or a particle board core, thickness as shown on Drawings or specified.
06 20 00 - 7
b. Cover exposed edges with plastic laminate, except where aluminum, stainless steel, or plastic molded edge strips are shown on drawings or specified. Use plastic molded edge strips on 19 mm
(3/4 inch) thick or thinner core material.
c. Provide plastic backing sheet on underside of countertops, vanity tops, thru-wall counter and sills including back splashes and end splashes of countertops.
d. Use backing sheet on concealed large panel surface when decorative face does not occur.
2.4 ACCESSORIES
A. Hardware:
1. Rough Hardware:
a. Provide rough hardware with a standard plating, applied after punching, forming and assembly of parts; galvanized, cadmium plated, or zinc-coated by electric-galvanizing process.
Galvanized where specified.
b. Fasteners:
1) Bolts with Nuts: FF-N-836.
2) Expansion Bolts: A-A-1922A.
3) Screws: Fed. Spec. FF-S-111.
2. Finish Hardware:
a. Cabinet Hardware: ANSI A156.9.
1) Door/Drawer Pulls: B02011.
2) Drawer Slides: B05051 for drawers over 150 mm (6 inches) deep, B05052 for drawers 75 mm to 150 mm (3 to 6 inches) deep, and
B05053 for drawers less than 75 mm (3 inches) deep.
3) Sliding Door Tracks: B07063.
4) Adjustable Shelf Standards: B4061 with shelf rest B04083.
5) Concealed Hinges: B1601, minimum 110 degree opening.
6) Butt Hinges: B01361, for flush doors.
7) Cabinet Door Catch: B0371 or B03172.
8) Vertical Slotted Shelf Standard: B04103 with shelf brackets
B04113, sized for shelf depth.
b. Cabinet Locks: ANSI A156.11.
1) Drawers and Hinged Door: E07262.
2) Sliding Door: E07162.
B. Adhesive:
06 20 00 - 8
1. Plastic Laminate: Fed. Spec. A-A-1936.
2. Interior Millwork: Unextended urea resin, unextended melamine resin, phenol resin, or resorcinol resin.
PART 3 - EXECUTION
3.1 PREPARATION
A. Examine and verify substrate suitability for product installation.
B. Protect existing construction and completed work from damage.
C. Clean substrates. Remove contaminants capable of affecting subsequently installed product's performance.
3.2 INSTALLATION
A. Installation:
1.
2. Coordinate with plumbing and electrical work for installation of fixtures and service connections in millwork items.
3. Plumb and level items unless shown otherwise.
3.3 CLEANING
A. Remove excess adhesive before adhesive sets.
B. Clean exposed surfaces. Remove contaminants and stains.
C. Touch up damaged factory finishes.
3.4 PROTECTION
A. Protect finish carpentry from traffic and construction operations.
B. Cover finish carpentry with reinforced kraft paper, and plywood or hardboard.
C. Remove protective materials immediately before acceptance.
D. Repair damage.
- - - E N D - - -
File details come from the government source that posted it. Updated .