36C25018B0803-027.pdf
PDF 15 MB Posted
- Attached to
- Renovate Building 83-2 515-14-108 Federal contract opportunity
- Solicitation number
- 36C25018B0803
About this file
36C25018B0803 515-14-108 Battle Creek 83-2 Patient Privacy BID Drawings_Part2.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25018B0803-0005000.docx | DOCX document | |
| 36C25018B0803-0005001.pdf | ||
| 36C25018B0803-0003001.pdf | ||
| 36C25018B0803-0003000.docx | DOCX document | |
| 36C25018B0803-0002003.zip | ZIP file | |
| 36C25018B0803-025.pdf | ||
| 36C25018B0803-024.pdf | ||
| 36C25018B0803-026.pdf | ||
| 36C25018B0803-022.docx | DOCX document | |
| 36C25018B0803-023.pdf | ||
| 36C25018B0803-000.docx | DOCX document |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NORTH
SECOND FLOOR ASBESTOS ABATEMENT PLAN
1/8" = 1'-0"HA121
F4
100% BID DOCUMENT SUBMISSION
FD
SSOE, Inc.
Project #
Troy, MI 48084
Suite 260
T 248-643-6222
1050 Wilshire Drive
015-02007-00
FULLY SPRINKLERED
100% BID DOCUMENT SUBMISSION
COMPLETION ITEM NO.
95% CONSTRUCTION DOCUMENTS
DESIGN DEVELOPMENT - NOT FOR CONSTRUCTION
95% CONSTRUCTION DOCUMENTS SUBMISSION
NOT FOR CONSTRUCTION
NORTH
GENERAL DEMOLITION NOTES:
1. COORDINATE DEMOLITION WORK WITH HAZARDOUS MATERIAL ABATEMENT CONTRACTOR
2. BUILDING STRUCTURE TO REMAIN, UNLESS NOTED OTHERWISE REMOVE FINISHES ON COLUMNS IN AREA OF WORK WHERE DEMOLITION IS
SHOWN AND PROTECT FROM DAMAGE DURING DEMOLITION PHASE.
3. PROVIDE ALL DEMOLITION WORK SHOWN ON THE DRAWINGS AND ALL RELATED AND INCIDENTAL DEMOLITION WORK REQUIRED. ALSO REFER TO
MEP/FP/FA DRAWINGS FOR SCOPE OF MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION AND FIRE ALARM DEMOLITION SCOPE OF WORK.
4. REMOVE CABINETRY, CASEWORK AND MILLWORK IN AREA OF WORK FROM ROOMS SCHEDULED TO UNDERGO RENOVATION. COORDINATE
FURNITURE MOVES WITH OWNER. STORE ALL APPROVED FURNITURE AND EQUIPMENT IN SECURED AREA AS DESIGNATED BY OWNER.
5. REMOVE TRIM AT CEILINGS, WINDOWS, DOORS, AND BASES IN AREA OF WORK.
6. REMOVE DOORS, GLAZING AND FRAMES FROM BUILDING INTERIORS IN AREA OF WORK.
7. REMOVE CERAMIC TILE IN AREA OF WORK.
8. REMOVE INTERIOR PARTITIONS AT TYPICAL ROOMS AND ALL INTERIOR MASONRY AT DUCT AND MISCELLANEOUS SHAFTS IN AREA OF WORK.
NOTIFY COR AND ARCHITECT OF UNEXPECTED CONDITIONS ENCOUNTERED.
9. REMOVE FINISH CEILINGS AND SUSPENSION SYSTEMS IN AREA OF WORK.
10.PRESERVE EXISTING FURRED WALL AND INSULATION AT EXTERIOR WALL, UNLESS NOTED OTHERWISE. REMOVE EXISTING WALL FINISH, AND
PREP WALL SURFACE FOR NEW FINISH.
11. UPON REMOVAL OF FINISH MATERIALS INDICATED OR REQUIRED, PREPARE SUBSTRATE TO RECEIVE NEW FINISH. REPAIR ANY EXISTING
DAMAGE, OR DAMAGE ARISING FROM DEMOLITION OPERATIONS TO MATCH EXISTING ADJACENT CONSTRUCTION.
12. PATCH AND REPAIR ALL DAMAGE ARISING FROM DEMOLITION OPERATIONS TO FLOOR, WALL AND CEILING SURFACES, TO MATCH EXISTING
ADJACENT CONSTRUCTION. PATCH ALL SPALLED CONCRETE CAUSED BY PARTITION REMOVAL. REMOVE ANY EXTRANEOUS MATERIAL AND PATCH
ANY DEPRESSIONS IN EXISTING SURFACES TO REMAIN.
13. REMOVE FLOOR BASE IN AREA OF WORK.
14.PATCH FLOOR OPENING WHERE EXISTING CONDUIT, PIPING, AND DUCT WORK ARE REMOVED AS DIRECTED. REFER TO STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. REFER TO DETAIL F1/AE503 FOR FILL-IN DETAIL.
15.FIELD VERIFY ALL EXISTING CONDITIONS, PRIOR TO START OF DEMOLITION OPERATIONS. BRING ANY DISCREPANCIES WHICH MAY SIGNIFICANTLY
AFFECT DEMOLITION TO THE ATTENTION OF THE COR FOR REVIEW.
16.PROTECT EXISTING CONSTRUCTION TO REMAIN FROM DAMAGE DURING DEMOLITION AND/OR CONSTRUCTION OPERATIONS.
17.DO NOT ALTER THE STRUCTURAL INTEGRITY OF THE EXISTING BUILDING OR ITS ASSEMBLIES UNLESS SPECIFICALLY NOTED OTHERWISE.
18.MAINTAIN EXIT ACCESS WAYS, AND KEEP FULLY SEPARATED FROM CONSTRUCTION AREA, AT ALL TIMES.
19.COORDINATE TIMING OF HOURS OF DEMOLITION OPERATIONS WITH THE OWNER.
20.COORDINATE START OF DEMOLITION OPERATIONS WITH THE OWNER.
21.ALL HVAC DUCT OPENINGS SHALL BE COMPLETELY SEALED TO PREVENT AIR MOVEMENT TO OR FROM THE CONSTRUCTION AREA VIA THE
BUILDING HVAC SYSTEM.
22.ANY EXISTING LIGHT FIXTURES BEING REMOVED PER DRAWINGS SHALL BE SALVAGED, AND RETURNED TO THE OWNER.
23.REFER TO INFECTION CONTROL INFORMATION IN SPECIFICATIONS.
24.PROVIDE TEMPORARY FILTERS TO PREVENT THE SPREAD OF DUST THROUGH THE BUILDING VIA THE RETURN AIR SYSTEM. UPON COMPLETION
OF DEMOLITION/CONSTRUCTION OPERATIONS, REMOVE BARRIERS AND REPAIR ANY DAMAGE CAUSED BY THEIR INSTALLATION OR PRESENCE TO
"LIKE NEW" CONDITION.
25. REMOVE EXISTING CEILING LIFTS AND TRACK SUPPORTS. RETURN TO THE OWNER.
26. REMOVE ALL WALL COVERINGS AND BORDERS. SKIM COAT WALL AND PREP SURFACES FOR NEW FINISHES.
27.REMOVE ALL SIGNAGE AND WALL HUNG ITEMS. PATCH AND REPAIR WALL. PREP WALL SURFACE FOR NEW FINISHES.
28. REMOVE EXISTING FIRE EXTINGUISHER CABINETS AND EXTINGUISHERS. RETURN TO THE OWNER.
29.REMODELING OR PATCHING SHALL BE EXECUTED IN CONJUNCTION WITH THE NEW WORK AND THE DEMOTION WORK IN THE DRAWINGS.
30.PATCH ALL EXPOSED INTERIOR FACES OF INTERIOR WALLS TO REMAIN WHERE ATTACHED OR IMBEDDED ITEMS WERE REMOVED. PATCH
COLUMN ENCLOSURES TO REMAIN WHERE INTERSECTING PARTITIONS WERE REMOVED.
31.THE CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARATION OF FLOORS, WALLS, COLUMN ENCLOSURES AND CEILINGS TO RECEIVE NEW
FINISHES.
32.PATCH AND PREPARE FLOOR WITH CONCRETE FLUSH WITH ADJACENT FLOOR SURFACE, FILL ANY SLOPING OR RECESSED AREAS LEVEL TO
TYPICAL FINISH FLOOR ELEVATION TO ACCOMMODATE NEW FLOOR FINISHES.
33.FILL IN EXISTING OPENINGS/PENETRATIONS IN WALLS, BULKHEADS, FLOOR OR ROOF DECK TO REMAIN, AS REQUIRED TO ENSURE INTEGRITY OF
EXISTING RATED SEPARATIONS. REFER TO DRAWING GI101 FOR REQUIRED RATINGS.
34.WHEN REMOVING DEBRIS FROM CONSTRUCTION AREA, WIPE OFF WHEELS BEFORE LEAVING CONSTRUCTION AREA AND USE WET RAGS OVER
DUMPSTER TO REDUCE DUST.
35.THE OWNER RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY TIME DUE TO NOISE AND VIBRATION WHICH MIGHT EFFECT THE
OWNER'S ONGOING USE OF THE FACILITY.
36.PATCH TO MATCH ANY FIRE PROOF COATINGS ON STRUCTURAL STEEL DISTURBED DUE TO DEMOLITION WORK.
37.REFER TO WALL TYPE T-1 FOR TYPICAL DETAIL OF TEMPORARY CONSTRUCTION PARTITIONS.
DEMOLITION KEYNOTES
CONSTRUCTION TO REMAIN
ITEMS TO BE REMOVED
2 HOUR FIRE BARRIER WALL SHAFT
(EXISTING TO REMAIN)
EXISTING MECHANICAL SHAFTS TO REMAIN
X
XROOM NO. X X X X
EXISTING ITEMS TO BE REMOVED IN EACH
NUMBERED ROOM (ENTIRE SECOND FLOOR)
(EXCLUDING STAIRS & ELEVATOR)
X X
SECOND FLOOR DEMOLITION PLAN
1/8" = 1'-0"AE141
F3
NOTES
LEGEND
1 1
4 5 6
4 5 6
4 5 64 5 6
4 5 6
4 5 6
4 5 6
4 5 6
4 5 6
4 5 6
4 5 6
8 5 6
4 5 6
4 5 6
4 5 6
4 5 6
4 5 6
4 5 6
4 5 6
4 5 6
4 5 6
4 5 6 4 5 6
4 5 6
4 5 6
7 7
7 7 7 7
S4
RM.TREATMENT
DAY ROOM
NURSING
BED RM
KITCHEN
CLST
HKA
LINEN
BED RM
210B
STATION
203A
MED
C22
OFFICE
BED RM
STORAGE
STAIR
S3
BED RM
DAY ROOM
BED RM
BED RM
244A
VISITOR
OFFICE
CONFERENCE
STOR
C21
202A
221 228
CLST
BED RM
BED RM
TOILET
250A
LAUNDRY
TOILET
HSKP
TOILET
238B
BED RM
BED RM
S2
BED RM
TLT
BED RM
E
OFFICE
250B
TLT
TLT
224A
CLEAN LINEN
232A
OFFICE
235A
STORAGE
KITCHEN
WAIT
C25B
53sf
TLT
226A
OFFICE
SW
LOCKER RM
FP
STATION
NURSES
BATH/
SHOWER
TOILET
239A
BATH/
SHOWER
238A
TOILET
SHOWER
FAMILY
LOUNGE
PIPE
219E
TLT.
229A
BED RM
BED RM
TOILET
BT/SHW
210A
BED RM
BED RM
STRG.
234A
BED RM
STAIR
STAIR
STAIR
S1
2 5 8
4 5 6
2 5 8
2 5 8
4 5 62
4 5 62
4 5 62
2 5 8
TLT
233A
4 5 62
BED RM
4 5 62
4 5 62
4 5 62
2 5 8
2 5 8
236A
BTH/SHW
4 52
2 5 8
4 5 62
4 5 62
4 52
2 5 8
TLT
225A
2 5 8
2 5 8
8 52
2 5 8
5 8
REMOVE EXISTING DOOR AND FRAME. REMOVE DOOR HARDWARE AND KEYPADS AND RETURN TO OWNER.
REMOVE EXISTING INTERIOR PARTITION/CHASE INCLUDING DOORS, FRAMES, WINDOWS AND ALL ITEMS ON AND WITHIN WALL. CONCEALED
ITEMS IN EXISTING PARTITIONS/CHASES ARE UNKNOWN. CAREFULLY REMOVE PORTIONS OF EXISTING PARTITIONS FROM FLOOR TO DECK
ABOVE. NOTIFY COR AND ARCHITECT OF UNKNOWN CONDITIONS ENCOUNTERED. CONTINUE DEMOLITION AFTER APPROVAL FROM COR.
REMOVE EXISTING PLUMBING FIXTURE. REFER TO PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION
REMOVE EXISTING FLOOR FINISH AND WALL BASE, PATCH FLOOR, AND WALL SURFACES. PREPARE FLOOR AND WALL SURFACE FOR NEW
FLOOR FINISH - REFER TO FINISH SCHEDULE
REMOVE EXISTING CEILING SYSTEM AND ALL ASSOCIATED HANGERS AND SUPPORTS. REMOVE EXISTING BULKHEADS AND FRAMING. REFER
TO ELECTRICAL DEMO DRAWINGS FOR LIGHT FIXTURE DEMO INFORMATION.
REMOVE FURNITURE/LOOSE EQUIPMENT AND RETURN TO OWNER.
CAREFULLY REMOVE PORTIONS OF EXISTING WALL/COLUMN COVERS AS REQUIRED FOR NEW WORK.
REMOVE WALL AND FLOOR TILE. PREPARE SUBSTRATE TO RECEIVE NEW FINISH PER MANUFACTURER'S RECOMMENDATIONS.
REMOVE CASEWORK. PATCH WALL AND FLOOR SURFACES FOR NEW FINISHES.
DEDUCT ALTERNATE: EXISTING DOOR, FRAME AND HARDWARE TO REMAIN/BE REUSED. PREP DOOR SURFACE FOR NEW FINISH.
REMOVE INFILL PANEL AND MECHANICAL DEVICE FROM EXISTING UPPER WINDOW SASH.
DEMO EXISTING RADIATOR HEATERS AND DDS CONTROLS BACK TO CONTROL PANEL. REFER TO MECHANICAL DEMOLITION DRAWINGS FOR
MORE INFORMATION.
CONDUITS TO REMAIN.
12 12
1 HOUR FIRE PARTITION
REMOVE EXISTING 1ST FLOOR CEILING AND OTHER TRADES' CONSTRUCTION
(CARPENTRY, DUCTWORK, PLUMBING PIPES, AND CONDUITS) AS REQUIRED FOR 2ND
FLOOR WORK. VERIFY ALL AFFECTED 1ST FLOOR AREAS. AFTER THE COMPLETION OF
2ND FLOOR WORK, PATCH, REPAIR, REINSTALL CEILING AND OTHER TRADES'
CONSTRUCTION ON THE 1ST FLOOR AND RESTORE TO THEIR ORIGINAL CONDITION.
MATCH EXISTING FINISHES. CONTRACTOR TO COORDINATE ALL TRADES. CONTRACTOR
MUST VERIFY EXISTING CONDITION ABOVE 1ST FLOOR CEILING PRIOR TO BIDS.
EXISTING FIRST FLOOR REFLECTED CEILING
PLAN
EXISTING FIRST FLOOR REFLECTED
CEILING PLAN
W
D
F
E
C
FEC
F E
C
F E
C
F
E
C
C
L
C
L
C
L
C
L
C
L
C
L
C
L
C
L
C
L
C
L
C
L
C
L
C
L
C
L
C
L
Ø
FD
FIREPLACE
FIREPLACE
TV
NORTH
DINING
BEDROOM-
BARIATRIC
CHARTING
EXIST.
STAIR
S2-2
BATH
256A
BATH
245A
EXIST.
STAIR
S3-2
BEDROOM
NE
PARLOR/DEN
BATH
221A
BEDROOM
BATH
214A
MEDS/MED
SELECT
BATH
210A
BATH
253A
SUITE
PASSAGE
C25
UNIT
COORDINATOR
LOCKER
ROOM
BATH
254A
CHARTING
BATH
243A
BEDROOM
CORRIDOR
C22
EXIST.
ELEVATOR
P2-1
CORRIDOR
C23
STAFF
LOUNGE
S U
I T
E
P A
S S
A G
E
C
EXIST.
STAIR
S1-2
N O
R T
H
K
I T
C H
E N
ELECTRICAL
BEDROOM
BEDROOM
EXIST.
STAIR
S4-2
NW
PARLOR/DEN
CEN. MEDICAL
SUPPLY
BEDROOM
BEDROOM
S O
I L
E D
U
T L
H O
L D
I N
G
BEDROOM
CORRIDOR
C32
BEDROOM
BATH
208A
CLEAN UTL.
BATH
236A
MULTI-PURPOSE
ROOM
OFFICE
EQUIPMENT
STORAGE
SHOWER RM
TOILET
OFFICE
STAFF
TOILET
234A
OFFICE
SUITE
PASSAGE
C35
BEDROOM-
BARIATRIC
BEDROOM
SE
PARLOR/DEN
ELECTRICAL
BEDROOM
MEDS/MED
SELECT
SW
PARLOR/DEN
CLOSET
BEDROOM
SOUTH KITCHEN
SOUTH
DINING
LIVING
ROOM
CHARTING
CLEAN
LINEN
HAC
CLOSET
CLEAN
LINEN
CHARTING
SUITE
PASSAGE
C27
LIVING
ROOM
SUITE
PASSAGE
C29
BEDROOM-
BARIATRIC
SUITE
PASSAGE
C38
C O
N F
E R
E N
C E
R O
O M
CORRIDOR
C33
CORRIDOR
C37
BATH
215A
LAUNDRY
HAC
BATH
252A
BATH
220A
ELEV.
LOBBY
SUITE
PASSAGE
C28
CORRIDOR
C30
HAC
STOR.
C O
R R
I D
O R
C
SUITE
PASSAGE
C36
SUITE
PASSAGE
C34
STORAGE
CLOSET
CLOSET
203A
BATH
257A
C23
203A
S
S
150°
C22
C32
C37
4'-10 1/4" 5'-1 1/4"
9 1/4"
8'-0"
HOLD
H O
L D
8'-0"
HOLD
ALIGN
ALIGN
ALIGN
ALIGN WALL
WITH WINDOW
ALIGN WALL
WITH WINDOW
9'-7"
ALIGN WALL
WITH SHAFT
A L
I G
N
W
A L
L
W I T
H
S
H A
F T
7'-4 1/2"
S2-4
BATH
227A
9'-11 1/2"
ALIGN WALL
WITH WINDOW
EXISTING
SHAFT
EXISTING
SHAFT
EXISTING
SHAFT
EXISTING
SHAFT
EXISTING
SHAFT
EXIST
SHAFT
EXISTING
SHAFT
EXISTING
SHAFT
EXISTING
SHAFT
EXISTING
SHAFT
EXISTING
SHAFT
EXISTING
SHAFT
EXISTING
SHAFT
H O
L D
H
O
L
D
SERVICE SINK
ALIGN WALL WITH
EXISTING SHAFT
10'-0 3/4" 6'-0"
ALIGN WALL WITH
EXISTING SHAFT
SERVICE SINK
CLOSET
CLOSET
CLOSET
CLOSET
CLOSET
CLOSET
CLOSET
C L
O S
E T
C L
O S
E T
CLOSET
CLOSET
CLOSET
CLOSET
CLOSET
C L
O S
E T
BEVERAGE
STATION
BEVERAGE
STATION
EXISTING PIPING TO REMAIN.
ENCLOSE WITH TYPE 'C5'
PARTITIONS AS REQUIRED. VERIFY
EXISTING CONDITIONS IN FIELD.
10'-6 3/4"
EXISTING PIPING TO REMAIN.
ENCLOSE WITH TYPE 'C5' PARTITIONS
AS REQUIRED. VERIFY EXISTING
CONDITIONS IN FIELD.
CG1
CG1
CG1
CG1
CG1
CG1
CG1 CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1 CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
WP1
WP1
WP1
WP1
WP1WP1
WP1
CORRIDOR
C26
WP1
WP1
WP1
WP1
CG1
WP2
WP2
WP2
WP1
WP2
WP2
WP3
WP3
WP2
WP2
WP2
WP2
WP3
WP3
WP3
WP3
WP3
WP3
WP3
WP3
WP3
WP3
WP2
WP2
WP3
W P
W P
WP2
OPEN WALL
OPEN WALL
CG1 CG1
CG1
ALIGN
1" INSULATED
GLAZING AT
UPPER SASH
FULLY SPRINKLERED
DESIGN DEVELOPMENT - NOT FOR CONSTRUCTION
SSOE, Inc.
Project #
Troy, MI 48084
Suite 260
T 248-643-6222
1050 Wilshire Drive
015-02007-00
FULLY SPRINKLERED
SCHEMATIC SUBMISSION - NOT FOR CONSTRUCTION
100% BID DOCUMENT SUBMISSION
COMPLETION ITEM NO.
95% CONSTRUCTION DOCUMENTS
DESIGN DEVELOPMENT - NOT FOR CONSTRUCTION
SCHEMATIC DESIGN_REV, MOD P00001 SUBMISSION
95% CONSTRUCTION DOCUMENTS SUBMISSION
NOT FOR CONSTRUCTION
NORTH
GENERAL CONSTRUCTION NOTES
1. DO NOT SCALE DRAWINGS. WORK FROM DIMENSIONS SHOWN. IF ADDITIONAL INFORMATION
IS NEEDED, OR WHERE DRAWINGS OR DRAWING SCALE APPEAR TO CONFLICT WITH
INDICATED DIMENSIONS, BRING TO THE ATTENTION OF THE ARCHITECT FOR REVIEW.
2. COORDINATE SCHEDULE OF OVERALL CONSTRUCTION AND DAY-TO-DAY CONSTRUCTION
OPERATIONS WITH OWNER'S SCHEDULE REQUIREMENTS.
3. FLOOR PLAN DRAWINGS ARE COMPOSITES OF EXISTING CONSTRUCTION TO REMAIN AND
NEW CONSTRUCTION. EXISTING CONSTRUCTION IS SHOWN IN LIGHTER, OUTLINE FORM.
NEW CONSTRUCTION IS INDICATED WITH HEAVIER LINEWORK AND MAY ADDITIONALLY BE
IDENTIFIED BY NOTE, KEYNOTE, LARGER SCALE DETAIL REFERENCE, OR MATERIAL PATTERN
(REFER ALSO TO LEGEND).
4. ALL WALL DIMENSIONS ARE TO FINISH FACE OF WALL UNLESS NOTED OTHERWISE
5. DOCUMENTS ARE BASED ON VA'S RECORD DRAWINGS AND LIMITED FIELD SURVEY. FIELD
VERIFY ALL PROJECT CONDITIONS PRIOR TO THE START OF, AND AS NEEDED DURING THE
COURSE OF, NEW CONSTRUCTION WORK. BRING ANY DISCREPANCIES WHICH MAY
SIGNIFICANTLY AFFECT NEW CONSTRUCTION WORK TO THE ATTENTION OF THE ARCHITECT
FOR REVIEW.
6. KEEP MEANS OF EGRESS OPEN, PROPERLY ILLUMINATED, AND FREE OF OBSTRUCTIONS AT
ALL TIMES.
7. WHERE NEW WALL CONSTRUCTION ABUTS EXISTING, IN-LINE, ON PLANS, DIRECTLY ALIGN
NEW FINISH WALL SURFACE(S) WITH EXISTING.
8. ALL WOOD BLOCKING AND BACKING SHALL BE FIRE-RETARDANT TREATED, UNLESS NOTED
OTHERWISE.
9. KEEP CONSTRUCTION NOISE TO A MINIMUM.
10. NO SMOKING IS ALLOWED INSIDE THE EXISTING BUILDING, INCLUDING AT THE
CONSTRUCTION AREA.
11. PATCH AND REPAIR DENTS, CRACKS, HOLES, AND/OR OTHER UNEVEN SURFACE CONDITIONS
IN EXISTING CONSTRUCTION TO REMAIN.
12. VERIFY THE DIMENSIONS, LOCATIONS, ELEVATIONS AND ARRANGEMENT OF ALL ITEMS
ASSOCIATED WITH INSTALLATION OF EQUIPMENT AND RELATED MECHANICAL AND
ELECTRICAL WORK.
13. NOTIFY THE OWNER AND ARCHITECT OF ANY CODE AND/OR CONSTRUCTION DEFICIENCIES
DISCOVERED OR UNCOVERED IN THE COURSE OF CONSTRUCTION OPERATIONS.
14. THE EXISTING BUILDING, AND ITS SUBSEQUENT CONSTRUCTION MODIFICATIONS, ARE
ASSUMED TO BE IN FULL COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS IN
EFFECT AT THE TIME OF CONSTRUCTION.
15. PATCH EXISTING FLOOR OPENINGS AFTER DEMO OF EXISTING MECHANICAL AND PLUMBING
SHAFTS. REFER TO DETAIL F1/AE503.
16. ALL WALLS SHALL EXTEND TO DECK ABOVE, UNLESS NOTED OTHERWISE. REFER TO TYPICAL
WALL TYPES.
17. WHERE EXISTING WALLS ARE INDICATED AS RATED WALLS, SEAL ALL PENETRATIONS AND
OPENINGS WITH FIRE STOPPING TO MAINTAIN INDICATED RATING. FIELD VERIFY.
18.EXISTING FLOOR IS FIRE RATED. SEAL ALL PENETRATIONS AND OPENINGS WITH FIRE
STOPPING TO MAINTAIN INDICATED RATING.
19.PROVIDE TEMPORARY DUST PARTITIONS AT FIRST AND SECOND FLOOR AND OTHER
OCCUPIED AREAS AS REQUIRED BY CONSTRUCTION WORK. REFER TO TYPICAL DETAILS ON
DRAWING.
20.PROVIDE BLOCKING/METAL SUPPORT STRAPS IN PARTITIONS FOR EQUIPMENT INSTALLATION
(I.E. GRAB BARS, TV MONITORS ETC.) REFER TO DRAWINGS FOR LOCATIONS.
21.VERIFY AND COORDINATE CLEAR CHASE SPACE REQUIREMENTS WITH WALL LOCATIONS FOR
WATER CLOSET AT EACH TOILET AND MECHANICAL AND ELECTRICAL. DUCTS, CONDUITS AND
PIPING WITH EXISTING STRUCTURE AND EXISTING UTILITIES BELOW. CHASE WALL
LOCATIONS SHALL BE ADJUSTED AS REQUIRED TO ALLOW FOR PROPER INSTALLATION
THROUGH EXISTING STRUCTURAL CONCRETE FLOOR SLAB. NOTIFY ARCHITECT PRIOR TO
PROCEEDING. EXISTING UTILITIES BELOW MAY HAVE TO BE REWORKED FOR NEW
CONSTRUCTION.
22. PROVIDE CEMENT BOARD AT ALL SHOWERS AND WET WALLS, TYPICAL.
23. EXISTING CLAY TILE AND PLASTER COLUMN AND STEAM PIPING ENCLOSURE TO REMAIN AT
EXTERIOR WALL COLUMNS. VERIFY EACH LOCATION. REPORT ANY DISCREPANCY TO
ARCHITECT.
24. REFER TO SHEET AE431, AE501 FOR TYPICAL BUILT-UP BATHROOM FLOOR INFORMATION.
25. REFER TO SHEET IN102 FOR TYPICAL WALL TILE LAYOUT DESIGN IN RESIDENT BATHROOMS.
PARTITION TYPE - PARTITION IS
TYPE "A" UNLESS OTHERWISE
NOTED. REFER TO SHEET GI100
FOR DETAILS
XX
2264A
DOOR NUMBER
ROOM NAME
XXX
ROOM TAG
AE4XX
INTERIOR ELEVATION.
REFER TO AE421, AE422,
AE423 AND AE424 FOR
ELEVATIONS
CORNER GUARD- REFER TO
AE502 FOR DETAILS
END GUARD- REFER TO AE502
FOR DETAILS
CG1
EG
FIRE EXTINGUISHER CABINET
REFER TO SPECIFICATIONS
FEC
EXISTING WALL
NEW WALLS
F1
AE421
C1
AE421
G6
AE421
F1
AE423
C1
AE422
B5
AE422
E3 AE424
F3AE424
E6
E5
AE424
E7
AE424
B7
B6B5 AE424
D6
D7
D3
AE424
A7
A6A5 AE424
B6
AE423
F5 AE424
F7
AE424
F6AE424
C2
AE422
A1
FLOOR PLAN LEGEND
OVERALL SECOND FLOOR PLAN
1/8" = 1'-0"AE121
F4
6'-3 1/4"
PATIENT BED CENTERLINE
D8
AE503
3 5/8" METAL STUDS AT 16" ON CENTER WITH ONE (1) LAYER OF 5/8" TYPE 'X' GYPSUM
BOARD ON EACH SIDE. EXTEND STUDS AND GYPSUM BOARD UP TO DECK ABOVE
(UNLESS NOTED OTHERWISE). PROVIDE 3 1/2" SOUND ATTENUATION BLANKETS BETWEEN
STUDS FULL HEIGHT.
3 5/8" METAL STUDS AT 16" ON CENTER WITH ONE (1) LAYER OF 5/8" TYPE 'X' GYPSUM
BOARD ON EACH SIDE. EXTEND STUDS AND GYPSUM BOARD UP TO DECK ABOVE.
PROVIDE 3 1/2" SOUND ATTENUATION BLANKETS BETWEEN STUDS FULL HEIGHT. WALL
TO BE FIRE RATED 1-HOUR (UL #U465)
TWO (2) ROWS 3 5/8" METAL STUDS AT 24" ON CENTER WITH ONE (1) LAYER OF 5/8" TYPE
'X' GYPSUM BOARD ON EACH SIDE. EXTEND STUDS AND GYPSUM BOARD UP TO DECK
ABOVE. PROVIDE 3 1/2" SOUND ATTENUATION BLANKETS BETWEEN STUDS FULL HEIGHT.
PARTITION SHALL BE 10" TOTAL THICKNESS. UNLESS NOTED OTHERWISE.
SOUND RATED SOUND TRANSMISSION CLASS 55.
5 1/2" METAL STUDS AT 16" ON CENTER WITH ONE (1) LAYER OF 5/8" TYPE 'X' GYPSUM
BOARD ON EACH SIDE. EXTEND STUDS AND GYPSUM BOARD UP TO DECK ABOVE
(UNLESS NOTED OTHERWISE). PROVIDE 3 1/2" SOUND ATTENUATION BLANKETS BETWEEN
STUDS FULL HEIGHT.
8" METAL STUDS AT 16" ON CENTER WITH ONE (1) LAYER OF 5/8" TYPE 'X' GYPSUM BOARD
ON EACH SIDE. EXTEND STUDS AND GYPSUM BOARD UP TO DECK ABOVE (UNLESS
NOTED OTHERWISE). PROVIDE 3 1/2" SOUND ATTENUATION BLANKETS BETWEEN STUDS
FULL HEIGHT.
3 5/8" METAL STUDS AT 16" ON CENTER WITH TWO (2) LAYERS OF 5/8" TYPE 'X' GYPSUM
BOARD ON EACH SIDE. EXTEND STUDS AND GYPSUM BOARD UP TO DECK ABOVE
(UNLESS NOTED OTHERWISE). PROVIDE 3 1/2" SOUND ATTENUATION BLANKETS BETWEEN
STUDS FULL HEIGHT. WALL TO BE FIRE RATED 2-HOURS (UL #U411)
EXTERIOR FURRED OUT WALL - 20 GAUGE, 3 5/8" METAL STUDS AT 16" ON CENTER WITH
ONE (1) LAYER 5/8" TYPE 'X' GYPSUM BOARD ON ONE SIDE ONLY AND VAPOR RETARDER.
HOLD STUDS 1" FROM EXTERIOR WALL SURFACE. EXTEND STUDS AND GYPSUM BOARD
TO DECK ABOVE. INFILL STUD SPACE WITH MINERAL WOOL INSULATION, FULL HEIGHT.
EXTERIOR FURRED OUT WALL - 20 GAUGE, 2 1/2" METAL STUDS AT 16" ON CENTER WITH
ONE (1) LAYER 5/8" TYPE 'X' GYPSUM BOARD ON ONE SIDE ONLY AND VAPOR RETARDER.
HOLD STUDS 1" FROM EXTERIOR WALL SURFACE. EXTEND STUDS AND GYPSUM BOARD
TO DECK ABOVE. INFILL STUD SPACE WITH MINERAL WOOL INSULATION, FULL HEIGHT.
EXTERIOR FURRED OUT WALL - 20 GAUGE, 5 1/2" METAL STUDS AT 16" ON CENTER WITH
ONE (1) LAYER 5/8" TYPE 'X' GYPSUM BOARD ON ONE SIDE ONLY AND VAPOR RETARDER.
HOLD STUDS 1" FROM EXTERIOR WALL SURFACE. EXTEND STUDS AND GYPSUM BOARD
TO DECK ABOVE. INFILL STUD SPACE WITH MINERAL WOOL INSULATION, FULL HEIGHT.
2 1/2" METAL STUDS AT 16" ON CENTER WITH ONE (1) LAYER OF TYPE 'X' GYPSUM BOARD
ON ONE SIDE ONLY. 3 1/2" SOUND ATTENUATION BLANKETS BETWEEN STUDS TO TOP OF
GYPSUM BOARD. EXTEND STUDS AND GYPSUM BOARD TO DECK ABOVE.
ONE (1) LAYER OF TYPE 'X' GYPSUM BOARD ON 7/8" METAL FURRING (ONE SIDE ONLY)
OVER EXISTING CONSTRUCTION . EXTEND GYPSUM BOARD AND FURRING TO 6" ABOVE
CEILING.
ONE (1) LAYER OF TYPE 'X' GYPSUM BOARD ON 3 5/8" METAL STUDS AT 16" ON CENTER
(ONE SIDE ONLY). EXTEND GYPSUM BOARD AND STUDS TO DECK ABOVE.
WALL TYPES
A2
A3
B1
C3
C4
S1
S2
S1
S1
S1
C5
S1
S1
S1
S1
S1
S1
S1
S1
S1
C3
C3
C3 C3
C3
C3C3
C3
C3
C3
C3
C3
C3
C3
C3
C3
A3
A2
A2
A2
A2
A2
A2
A2
A2
S2
S2
A
C3
B3, D3
AE501
C
L
FD
FLOOR DRAIN
SEE GI-100 FOR PARTITION TYPE
LEGEND
S1
C5
C5
F1
AE431
F3
AE431
E5
AE431
B2
AE422
F5
AE431
F7
AE431
C2
AE431
B2
AE431
C4
AE431
C6
AE431
WALL PROTECTION. REFER TO
DETAIL B9/AE502
WP1
WALL PROTECTION. REFER TO
DETAIL C9/AE502
WP2
WALL PROTECTION. REFER TO
DETAIL B8/AE502
WP3
A4
C2
A3 AE424
C5
C5
B3AE424
B1
AE502
SHADED AREA INDICATED REINFORCED
CONCRETE SLAB BY GLUED CARBON
FIBER STRIPS TO BOTTOM OF SLABS.
SEE DETAIL ON THIS SHEET FOR MORE
INFORMATION.
A3
AE502
F1
AE501
B1
AE424
A5
SLAB S29
EXISTING SLAB FLEXURAL CAPACITY = 27.1 K-IN
REQUIRED SLAB FLEXURAL CAPACITY = 31.2 K-IN
SLAB S30
EXISTING SLAB FLEXURAL
CAPACITY = 13.9 K-IN
REQUIRED SLAB FLEXURAL
CAPACITY = 19.0 K-IN
SHADED AREA INDICATED REINFORCED
CONCRETE SLAB BY GLUED CARBON
FIBER STRIPS TO BOTTOM OF SLABS.
SEE DETAIL ON THIS SHEET FOR MORE
INFORMATION..
SLAB S29
EXISTING SLAB FLEXURAL
CAPACITY = 27.1 K-IN
REQUIRED SLAB FLEXURAL
CAPACITY = 31.2 K-IN
SLAB S30
EXISTING SLAB FLEXURAL
CAPACITY = 13.9 K-IN
REQUIRED SLAB FLEXURAL
CAPACITY = 19.0 K-IN
C
L
C
L
C
L
C
L
C
L
C
L
C
L
C
L
C
L
C
L
C
L
C
L
C
L
C
L
C
L
FD
R a c a c a ba bac a
R
R
R
EXP
EXP
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-6"
7'-0"
3'-10" 4'-3"
2'-4"
7'-1 3/4"
4'-7"
2'-9"
7'-6"
7'-0"
NORTH
DINING
BEDROOM-
BARIATRIC
CHARTING
EXIST.
STAIR
S2-2
BATH
256A
BATH
245A
EXIST.
STAIR
S3-2
BEDROOM
NE
PARLOR/DEN
BATH
221A
BEDROOM
BATH
214A
BATH
210A
BATH
253A
SUITE
PASSAGE
C25
UNIT
COORDINATOR
LOCKER
ROOM
BATH
254A
CHARTING
BATH
243A
BEDROOM
CORRIDOR
C22
EXIST.
ELEVATOR
P2-1
CORRIDOR
C23
STAFF
LOUNGE
SUITE
PASSAGE
C31
EXIST.
STAIR
S1-2
NORTH KITCHEN
ELECTRICAL
BATH
227A
BEDROOM
BEDROOM
EXIST.
STAIR
S4-2
NW
PARLOR/DEN
CEN. MEDICAL
SUPPLY
BEDROOM
BEDROOM
SOILED UTL/
HOLDING
BEDROOM
CORRIDOR
C32
BEDROOM
BATH
208A
CLEAN UTL.
BATH
236A
MULTI-PURPOSE
ROOM
OFFICE
EQUIPMENT
STORAGE
SHOWER RM
TOILET
OFFICE
STAFF
TOILET
234A
OFFICE
SUITE
PASSAGE
C35
BEDROOM-
BARIATRIC
BEDROOM
SE
PARLOR/DEN
ELECTRICAL
BEDROOM
MEDS/MED
SELECT
SW
PARLOR/DEN
BEDROOM
SOUTH KITCHEN
SOUTH
DINING
LIVING
ROOM
CHARTING
CLEAN
LINEN
HAC
CLOSET
CLEAN
LINEN
CHARTING
SUITE
PASSAGE
C27
LIVING
ROOM
SUITE
PASSAGE
C29
BEDROOM-
BARIATRIC
SUITE
PASSAGE
C38
CONFERENCE
ROOM
CORRIDOR
C33
CORRIDOR
C37
BATH
215A
LAUNDRY
HAC
BATH
252A
BATH
220A
ELEV.
LOBBY
CORRIDOR
C26
CORRIDOR
C28
CORRIDOR
C30
HAC STOR.
CORRIDOR
C24
CORRIDOR
C36
SUITE
PASSAGE
C34
STORAGE
CLOSET
CLOSET
203A
BATH
257A
CLOSET
1'-10"
5'-1"
1'-0"
4'-0"
2'-9"
3'-0"
7'-6"
2'-9"
E Q
E Q
R
R
R
7'-0"
E Q
E
Q
2'-6"
5'-1"
4'-0"
EQ
EQ
2'-9"
3'-1"
3'-0"
6'-0" 2'-8"
2'-0"
7'-0"
MEDS/MED
SELECT
ALIGN
ALIGN
E Q
E Q
2'-0
5'-0"
R
T Y
P I C
A L
SOFFIT HEIGHT
REFER TO CEILING PLAN
VARIES REFER TO REFLECTED CEILING PLAN
CEILING SYSTEM
5/8" GYPSUM
BOARD ON METAL
STUD FRAMING AT
16" ON CENTER.
CEILING HEIGHT
REFER TO CEILING PLAN
3 5/8" METAL STUD,
DIAGONAL BRACE AT
4'-0" ON CENTER
T Y
P I C
A L
CEILING HEIGHT
REFER TO CEILING PLAN
SOFFIT HEIGHT
REFER TO CEILING PLAN
REFER TO
REFLECTED CEILING PLAN
3 5/8" METAL STUD,
DIAGONAL BRACE AT
4'-0" ON CENTER
CEILING SYSTEM
5/8" GYPSUM
BOARD ON METAL
STUD FRAMING AT
16" ON CENTER
T Y
P I C
A L
CEILING HEIGHT
REFER TO CEILING PLAN
CEILING SYSTEM
5/8" GYPSUM
BOARD ON METAL
STUD FRAMING AT
16" ON CENTER
3 5/8" METAL STUD
DIAGONAL BRACE
AT 4'-0" ON CENTER
12" 12"
M B
E D
EXISTING
FLOOR SLAB
WT5X16.5 ORIENTED
PERPENDICULAR TO
DIRECTION OF SLAB
SPAN
LIFT HANGER, BY
LIFT
MANUFACTURER
1/2" DIAMETER HILTI
KWIK HUS-EZ
SCREW ANCHORS
NS/FS IN WT
FLANGE (4
ANCHORS TOTAL).
EMBED 2 1/4"
DO NOT ATTACH
TO BOTTOM OF
EXISTING JOIST,
TYPICAL
ATTACH TO THE SIDE
OF CONCRETE PAN
JOIST AS SHOWN
SUPPORT SYSTEM,
AS REQUIRED, BY
LIFT MANUFACTURER
CEILING
SYSTEM
PATIENT LIFT
TRACK, BY LIFT
MANUFACTURER
(2) 3/4" DIAMETER
HILTI KWIK BOLT
3 EXP ANCHORS
NS/FS IN WT
FLANGE.
MINIMUM EMBED
= 3 1/2"
WT5X16.5
EXISTING WALL
AND WINDOW
ALIGN BULKHEAD
WITH WINDOW
MATCH NEW SOFFIT
HEIGHT WITH EXISTING
WINDOW HEAD
CEILING HEIGHT 7'-10"
ABOVE FINISH FLOOR
CEILING HEIGHT 8'-0"
ABOVE FINISH FLOOR
5"
9"
ALIGN BULKHEAD
WITH WINDOW
MATCH NEW SOFFIT
HEIGHT WITH
EXISTING WINDOW
HEAD
EXISTING WALL
AND WINDOW
CEILING HEIGHT 7'-10"
ABOVE FINISH FLOOR
CEILING HEIGHT 8'-0"
ABOVE FINISH FLOOR
CEILING HEIGHT 7'-6"
ABOVE FINISH FLOOR
SSOE, Inc.
Project #
Troy, MI 48084
Suite 260
T 248-643-6222
1050 Wilshire Drive
015-02007-00
FULLY SPRINKLERED
SCHEMATIC SUBMISSION - NOT FOR CONSTRUCTION
100% BID DOCUMENT SUBMISSION
COMPLETION ITEM NO.
95% CONSTRUCTION DOCUMENTS
DESIGN DEVELOPMENT - NOT FOR CONSTRUCTION
SCHEMATIC DESIGN_REV, MOD P00001 SUBMISSION
95% CONSTRUCTION DOCUMENTS SUBMISSION
NOT FOR CONSTRUCTION
SECOND FLOOR REFLECTED CEILING PLAN
1/8" = 1'-0"AE121
F3
RECESSED DOWNLIGHT
REFER TO ELECTRICAL
2' X 4' LIGHT FIXTURE
REFER TO ELECTRICAL
2X2 ACOUSTIC CEILING TILE GRID
(SEE ROOM FINISH SCHEDULE)
PAINTED GYPSUM BOARD CEILING
CEILING HEIGHT
EXPOSED TO STRUCTURE ABOVE
2' X 2' LIGHT FIXTURE
REFER TO ELECTRICAL
LIFT TRACK
NOTES
REFLECTED CEILING PLAN NOTES
1. CONTRACTOR SHALL ADJUST CEILING GRIDS TO
CENTER THEM IN ROOMS AND CREATE EQUAL TILE
SPACING AT ENDS OF ROOMS.
2. ALL TECHNOLOGY EQUIPMENT LOCATIONS ARE
DIAGRAMMATIC. REFER TO THE TECHNOLOGY
DRAWINGS. COORDINATE FINAL LOCATION OF
CEILING MOUNTED EQUIPMENT WITH ALL TRADES.
3. ALL LIGHT FIXTURE, MECHANICAL DIFFUSER
LOCATIONS AND TECHNOLOGY ITEMS ARE
DIAGRAMMATIC IN NATURE AND SOME ITEMS MAY
NOT BE SHOWN FOR CLARITY. REFER TO THE
MECHANICAL AND ELECTRICAL DRAWINGS FOR ALL
ITEMS TO BE PROVIDED. COORDINATE FINAL
LOCATION OF CEILING MOUNTED EQUIPMENT WITH
ALL TRADES.
4. ALL CEILING TO BE 8'-0" (UNLESS NOTED
OTHERWISE).
5. LIGHTS ARE TO BE CENTERED IN BATHROOM AND
SHOWERS (UNLESS NOTED OTHERWISE).
LEGEND
RATED WALL LEGEND
2 HOUR FIRE BARRIER
(EXISTING)
1 HOUR FIRE BARRIER (NEW)
SMOKE BARRIER (NEW)
WIDE SOFFIT DETAIL
1 1/2" = 1'-0"AE221
F1
SOFFIT AT WALL DETAIL
1 1/2" = 1'-0"AE221
E1
E1
AE221
D1
AE221
TYPICAL
F1
AE221
C1
AE221
1X4 LIGHT FIXTURE
REFER TO ELECTRICAL
7'-6"
EXP
CEILING TRANSITION DETAIL
1 1/2" = 1'-0"AE221
C1
TYPICAL PATIENT LIFT BRACKET AT CONCRETE SLAB
1 1/2" = 1'-0"AE221
B1
TYPICAL PATIENT LIFT SUPPORT
1 1/2" = 1'-0"AE221
A1
V E
R I F
Y
KEYNOTES
REFER TO DETAIL B1/AE501 FOR SOFFIT DETAIL.
REFER TO DETAIL B4/AE501 FOR SOFFIT DETAIL.
REFER TO DETAIL C1/AE221 FOR CEILING
TRANSITION DETAIL.
F4
AE221
TYPICAL
11111
1 1
1 1
1 1
1 2
TYPICAL
PLAN DETAIL AT WINDOW SOFFIT
1 1/2" = 1'-0"AE221
F4 PLAN DETAIL AT WINDOW SOFFIT
1 1/2" = 1'-0"AE221
F6
F6
AE221
B1
AE501
B1
AE501
B4
AE501
PRIVACY CURTAIN TRACK
AIR SUPPLY GRILLE.
REFER TO MECHANICAL
AIR RETURN GRILLE.
REFER TO MECHANICAL
CEILING MOUNTED SPEAKER
REFER TO TELECOMMUNICATIONS
Y
P
PENDANT LIGHT FIXTURE
F1
AE221
E1
AE221
TYPICAL
http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com
220A
C
C
A
F E
C
C
L
C
L
6'-7"
5'-0"
BEDROOM
NE
PARLOR/DEN
BATH
221A
BEDROOM
CLOSET
SUITE
PASSAGE
C29
BATH
220A
2'-8"
LAV
LAV
WC
WC
C3
C3
C2
C4S1
C5
C3
C3
C3
A3
A3
11'-7"
6'-1 1/2"
5'-1" 4'-4 3/4" 7'-4"
A01
A14
E X
I S
T I N
G
S H
A F
T
SHELF AND
ROD REFER
TO B8/AE501
A01
A14
A06
ADA MARBLE
THRESHOLD
(TYPICAL)
REFER TO
DETAIL
F7/AE501
SHOWER
SHOWER
A06
SAFETY GLAZING SECURITY FILM -
INSTALL ON INSIDE FACE OF
EXISTING GLAZING
TV
CLOSET
CLOSET
TV
PROVIDE PRIVACY
WINDOW FILM ON
BATHROOM
WINDOWS
(TYPICAL)
PROVIDE
PRIVACY
WINDOW FILM
ON BATHROOM
WINDOWS
(TYPICAL)
A18
A18
CG1
CG1
EG
CG1
CG1
CG1
WP1
WP1
WP1
C3C3
C2
C3
C3
C3
C3
FD
FD
FEC
FD
WP3
WP3
WP3
WP3
Ø
C
210A
S2-4
C
L
ALIGN
2'-2" 5'-0" 3'-3" 5'-8" 4'-10"
BEDROOM-
BARIATRIC
BATH
210A
CHARTING
CLEAN
LINEN
SUITE
PASSAGE
C27
CORRIDOR
C26
LAV
WC
1'-0"
4'-6"
C4
C4
C4
S1
S1
C3
C3
A2
10'-0"
CLOSET
SHOWER
A06
A14
A1
EXISTING
SHAFT
WALL MOUNTED
CHARTING STATION.
PROVIDE BLOCKING
AS REQUIRED
SAFETY GLAZING SECURITY FILM -
INSTALL ON INSIDE FACE OF
EXISTING GLAZING
PROVIDE PRIVACY FILM ON ALL
BATHROOM WINDOWS (TYPICAL)
A18
CG1
CG1
CG1
C3
FD
FD
CG1
CG1
WP3
A10
A05
A14
A08
A02
A21
A20
3'-0" 2'-0"
3'-0"
SHOWER WIDTH
6"
A06
A09
A03
A10
A18
EQUAL EQUAL
A12
A10
A07
A05
A11
A09
A06
3'-0"
SHOWER WIDTH
6"
A18
A01
EXISTING WINDOW
PRIVACY WINDOW
FILM AND SAFETY
GLAZING SECURITY
FILM
CEILING POCKET BEYOND
REFER TO DETAIL B1/AE501
PLASTIC LAMINATE
SIDE PANEL
A21
A14
A08
A02
A21
A13
A06
EXISTING
WINDOW
3'-0" 2'-0"
PRIVACY WINDOW
FILM AND SAFETY
GLAZING
A01
A19
(CENTER
ON WALL)
EXISTING
WINDOW
PRIVACY WINDOW
FILM AND SAFETY
GLAZING
A21
PLASTIC LAMINATE
A05
A10
A12
PRIVACY WINDOW
3'-0"
SHOWER WIDTH
6"
A09
A06
A03
A10
A18
EQUAL EQUAL
A14
A08
A02
A06
A09
A21
A07
A05
A10
3'-0" 2'-0"
A18
A11
A03
A09
A06
A10
A18
EQUALEQUAL
A11
A05
A19
(CENTER ON
WALL)
PRIVACY
WINDOW
FILM
EXISTING
WINDOW
3'-0"
SHOWER WIDTH
6"
A01
(CENTER ON
A12
A21
PLASTIC
LAMINATE
SIDE PANEL
W
D
A
C
C
A
F
E
C
C
L
C
L
8'-1 1/4"
2'-7"
5'-0"
9'-7"2'-7"5'-0"
4'-5"4'-5"
5'-9"
5'-9"
BATH
214A
SUITE
PASSAGE
C25
BEDROOM
BEDROOM
BATH
215A
CORRIDOR
C24
LAV
LAV
WC
WC
C3
C3
C3
C3
A3
A3
A3 S1
A01
A14
A14
A01
SHOWER
SHOWER
A06
A06
ALIGN WALL WITH
EXISTING WINDOW
CLOSET
CLOSET
TV
TV
8'-0"
A18
A18
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
WP1
WP1
WP1
FD
WP1
ADA
THRESHOLD
(TYPICAL)
REFER TO
DETAIL F7/AE501
FD
FD
FEC
S2
W/
INSULATION
A3
ADA
THRESHOLD
(TYPICAL)
REFER TO
DETAIL F7/AE501
C3
BELOW
WINDOW
WP3
WP3
WP3
WP3
WP3
WP3
WP3
Ø
Ø6'-4" TYP.
T
Y
P
A07
A05
A11
A10
A20
6"
3'-0"
SHOWER WIDTH
A01
A12
2'-9"
PLASTIC
LAMINATE
SIDE PANEL
A05
A10
A14
A08
A02
A15
A06
A09
A21
3'-0" 2'-0"
A18
A03
A09
A06
A10
A18
EQUAL EQUAL
A20
A10
A11
A07
A05
3'-0"
SHOWER WIDTH
6"
3'-0"
SHOWER WIDTH
A09
A03
A06
A10
A18
EQUALEQUAL
A14
A08
A02
A09
A06
A21
2'-0" 3'-0"
A18
A01
A12
2'-0"
A21
PLASTIC LAMINATE
SIDE PANEL
4'-6"
BASE
REFER TO FINISH
SCHEDULE
CHARTING
STATION
CORNER
GUARD
4'-6"
BASE
REFER TO
FINISH
SCHEDULE
SSOE, Inc.
Project #
Troy, MI 48084
Suite 260
T 248-643-6222
1050 Wilshire Drive
015-02007-00
SCHEMATIC SUBMISSION - NOT FOR CONSTRUCTION
100% BID DOCUMENT SUBMISSION
95% CONSTRUCTION DOCUMENTS
DESIGN DEVELOPMENT - NOT FOR CONSTRUCTION
SCHEMATIC DESIGN_REV, MOD P00001 SUBMISSION
95% CONSTRUCTION DOCUMENTS SUBMISSION
NOT FOR CONSTRUCTION
NORTHNORTH
SECOND FLOOR ENLARGED PLAN
1/4" = 1'-0"AE121
F1
C1AE503
C3 AE503
C1
AE503
D7
C7
D6C6 AE421
D4
C4
D3C3 AE421
F4
E4
F3E3 AE421
BATH 220A
1/4" = 1'-0"AE421
E3
F3
BATH 221A
C3
C4
D3
D4
BATH 215A
A3 BATH 215A
A4
BATH 215A
B3 BATH 215A
B4
BATH 214A
A6 BATH 214A
A7
B6
B7
BATH 210A
1/4" = 1'-0"AE421
D6 BATH 210A
1/4" = 1'-0"AE421
D7
BATH 210A
1/4" = 1'-0"AE421
C6 BATH 210A
1/4" = 1'-0"AE421
C7
SECOND FLOOR ENLARGED PLAN
1/4" = 1'-0"AE121
G6
D8
C8
AE421
B7
A7
B6A6 AE421
B4
A4
B3A3 AE421
C3
AE503
C1
AE503
B1
AE510
B1
AE510
B1
AE510
B1
AE510
B1
AE510
CHARTING 209
C8
D8
B3,D3
AE501
B3,D3
AE501
ABBREVIATIONS:
C/C CONTRACTOR FURNISHED/CONTRACTOR INSTALLED
V/C VA FURNISHED/CONTRACTOR INSTALLED V/V VA FURNISHED/ VA INSTALLED
F8
AE510
B3,D3
AE501
BATHROOM ACCESSORY LEGEND
ID # DESCRIPTION
PROVIDED/
INSTALLED
BLOCKING
REQUIRED
A01
DISPENSER, PAPER TOWEL, STAINLESS STEEL, SURFACE
MOUNTED
V/C YES
A02
DISPENSER, SOAP
V/C NO
A03
42" GRAB BAR, 1 1/4" DIAMETER STAINLESS STEEL, WHEELCHAIR
ACCESSIBLE
C/C YES
A04
36" GRAB BAR, 1 1/4" DIAMETER STAINLESS STEEL, WHEELCHAIR
ACCESSIBLE
C/C YES
A05
24" GRAB BAR, 1 1/4" DIAMETER, WHEELCHAIR ACCESSIBLE
C/C YES
A06
24" UP-SWINGING GRAB BAR, 1 1/4" DIAMETER, STAINLESS
STEEL, WHEELCHAIR ACCESSIBLE
C/C YES
A07
18" VERTICAL GRAB BAR, 1 1/4" DIAMETER STAINLESS STEEL
C/C YES
A08
MIRROR, FLOAT GLASS, WITH WOOD FRAME (18"W X 30" H)
C/C NO
A09 NURSE CALL C/C NO
A10
ROD, SHOWER, WITH CURTAIN
C/C NO
A11
SHOWER, HANDHELD
C/C NO
A12
HOOK, GARMENT, DOUBLE
C/C YES
A13 NOT USED - -
A14 RECESSED CABINET C/C YES
A15 NOT USED
A16 NOT USED - -
A17
MEDICINE CABINET, REFER TO DETAIL F3/AE502 UNLESS NOTED
OTHERWISE.
- YES
A18 TOILET TISSUE DISPENSER C/C YES
A19 24" TOWEL BAR C/C YES
A20 36" TOWEL BAR C/C YES
A21 WALL MOUNTED VANITY FIXTURE C/C NO
NORTH
SECOND FLOOR ENLARGED PLAN
1/4" = 1'-0"AE121
C1
GENERAL CONSTRUCTION NOTES
FLOOR PLAN LEGEND
B8
AE501
TYPICAL
SIMILAR
PARTITION TYPE - PARTITION IS
TYPE "A" UNLESS OTHERWISE
NOTED. REFER TO SHEET GI100
FOR DETAILS
XX
DOOR NUMBER
ROOM NAME
INTERIOR ELEVATION KEY.
REFER TO AE421, AE422,
AE423, AND AE424 FOR
ELEVATIONS
CORNER GUARD- REFER TO
AE502 FOR DETAILS
END GUARD- REFER TO AE502
FOR DETAILS
CG1
EG
FIRE EXTINGUISHER CABINET
REFER TO SPECIFICATIONS
FEC
EXISTING WALL
NEW WALLS
PATIENT BED CENTERLINE
C
L
FD
FLOOR DRAIN
WALL PROTECTION. REFER TO
DETAIL B9/AE502
WP1
WALL PROTECTION. REFER TO
DETAIL C9/AE502
WP2
WALL PROTECTION. REFER TO
DETAIL B8/AE502
WP3
1. DO NOT SCALE DRAWINGS. WORK FROM DIMENSIONS SHOWN. IF ADDITIONAL INFORMATION
IS NEEDED, OR WHERE DRAWINGS OR DRAWING SCALE APPEAR TO CONFLICT WITH
INDICATED DIMENSIONS, BRING TO THE ATTENTION OF THE ARCHITECT FOR REVIEW.
2. COORDINATE SCHEDULE OF OVERALL CONSTRUCTION AND DAY-TO-DAY CONSTRUCTION
OPERATIONS WITH OWNER'S SCHEDULE REQUIREMENTS.
3. FLOOR PLAN DRAWINGS ARE COMPOSITES OF EXISTING CONSTRUCTION TO REMAIN AND
NEW CONSTRUCTION. EXISTING CONSTRUCTION IS SHOWN IN LIGHTER, OUTLINE FORM.
NEW CONSTRUCTION IS INDICATED WITH HEAVIER LINEWORK AND MAY ADDITIONALLY BE
IDENTIFIED BY NOTE, KEYNOTE, LARGER SCALE DETAIL REFERENCE, OR MATERIAL PATTERN
(REFER ALSO TO LEGEND).
4. ALL WALL DIMENSIONS ARE TO FINISH FACE OF WALL UNLESS NOTED OTHERWISE
5. DOCUMENTS ARE BASED ON VA'S RECORD DRAWINGS AND LIMITED FIELD SURVEY. FIELD
VERIFY ALL PROJECT CONDITIONS PRIOR TO THE START OF, AND AS NEEDED DURING THE
COURSE OF, NEW CONSTRUCTION WORK. BRING ANY DISCREPANCIES WHICH MAY
SIGNIFICANTLY AFFECT NEW CONSTRUCTION WORK TO THE ATTENTION OF THE ARCHITECT
FOR REVIEW.
6. KEEP MEANS OF EGRESS OPEN, PROPERLY ILLUMINATED, AND FREE OF OBSTRUCTIONS AT
ALL TIMES.
7. WHERE NEW WALL CONSTRUCTION ABUTS EXISTING, IN-LINE, ON PLANS, DIRECTLY ALIGN
NEW FINISH WALL SURFACE(S) WITH EXISTING.
8. ALL WOOD BLOCKING AND BACKING SHALL BE FIRE-RETARDANT TREATED, UNLESS NOTED
OTHERWISE.
9. KEEP CONSTRUCTION NOISE TO A MINIMUM.
10. NO SMOKING IS ALLOWED INSIDE THE EXISTING BUILDING, INCLUDING AT THE
CONSTRUCTION AREA.
11. PATCH AND REPAIR DENTS, CRACKS, HOLES, AND/OR OTHER UNEVEN SURFACE CONDITIONS
IN EXISTING CONSTRUCTION TO REMAIN.
12. VERIFY THE DIMENSIONS, LOCATIONS, ELEVATIONS AND ARRANGEMENT OF ALL ITEMS
ASSOCIATED WITH INSTALLATION OF EQUIPMENT AND RELATED MECHANICAL AND
ELECTRICAL WORK.
13. NOTIFY THE OWNER AND ARCHITECT OF ANY CODE AND/OR CONSTRUCTION DEFICIENCIES
DISCOVERED OR UNCOVERED IN THE COURSE OF CONSTRUCTION OPERATIONS.
14. THE EXISTING BUILDING, AND ITS SUBSEQUENT CONSTRUCTION MODIFICATIONS, ARE
ASSUMED TO BE IN FULL COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS IN
EFFECT AT THE TIME OF CONSTRUCTION.
15. PATCH EXISTING FLOOR OPENINGS AFTER DEMO OF EXISTING MECHANICAL AND PLUMBING
SHAFTS. REFER TO DETAIL F1/AE503.
16. ALL WALLS SHALL EXTEND TO DECK ABOVE, UNLESS NOTED OTHERWISE. REFER TO TYPICAL
WALL TYPES.
17. WHERE EXISTING WALLS ARE INDICATED AS RATED WALLS, SEAL ALL PENETRATIONS AND
OPENINGS WITH FIRE STOPPING TO MAINTAIN INDICATED RATING. FIELD VERIFY.
18.EXISTING FLOOR IS FIRE RATED. SEAL ALL PENETRATIONS AND OPENINGS WITH FIRE
STOPPING TO MAINTAIN INDICATED RATING.
19.PROVIDE TEMPORARY DUST PARTITIONS AT FIRST AND SECOND FLOOR AND OTHER 1 HR
FIRE RATED SEPARATION REQUIRED OCCUPIED AREAS AS REQUIRED BY CONSTRUCTION
WORK. REFER TO T-1 WALL TYPE.
20.PROVIDE BLOCKING/METAL SUPPORT STRAPS IN PARTITIONS FOR EQUIPMENT INSTALLATION
(I.E. GRAB BARS, TV MONITORS ETC.) REFER TO DRAWINGS FOR LOCATIONS.
21.VERIFY AND COORDINATE CLEAR CHASE SPACE REQUIREMENTS WITH WALL LOCATIONS FOR
WATER CLOSET AT EACH TOILET AND MECHANICAL AND ELECTRICAL. DUCTS, CONDUITS AND
PIPING WITH EXISTING STRUCTURE AND EXISTING UTILITIES BELOW. CHASE WALL
LOCATIONS SHALL BE ADJUSTED AS REQUIRED TO ALLOW FOR PROPER INSTALLATION
THROUGH EXISTING STRUCTURAL CONCRETE FLOOR SLAB. NOTIFY ARCHITECT PRIOR TO
PROCEEDING. EXISTING UTILITIES BELOW MAY HAVE TO BE REWORKED FOR NEW
CONSTRUCTION.
22. PROVIDE CEMENT BOARD AT ALL SHOWERS AND WET WALLS, TYPICAL.
23. EXISTING CLAY TILE AND PLASTER COLUMN AND STEAM PIPING ENCLOSURE TO REMAIN AT
EXTERIOR WALL COLUMNS. VERIFY EACH LOCATION. REPORT ANY DISCREPANCY TO
ARCHITECT.
24. REFER TO SHEET AE431, AE501 FOR TYPICAL BUILT-UP BATHROOM FLOOR INFORMATION.
25. REFER TO SHEET IN102 FOR TYPICAL WALL TILE LAYOUT DESIGN IN RESIDENT BATHROOMS.
A2
AE502
C3
AE502
C1
AE502
C8
F8
AE510
XXX
F8
AE510
REFER TO STD MOUNTING HEIGHTS
ON GI100
http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com
227A
C
C
L
BATH
227A
SOILED UTL/
HOLDING
BEDROOM
8'-5 3/4"5'-1" 5'-0" 2'-2"
ALIGN
ALIGN WALL WITH
EXISTING SHAFT WC
LAV
SHOWER
A01
A14
A
C4
S1
S2 S2
C3 C3
A2
A2
A2
A2
SAFETY GLAZING
SECURITY FILM -
INSTALL ON INSIDE
FACE OF EXISTING
GLAZING
ALIGN
ALIGN WALL WITH
EXISTING STAIRWELL
WALL
CLOSET
TV
CLINICAL
SINK
HAND
SINK
3'-2"
PROVIDE PRIVACY
FILM ON ALL
BATHROOM WINDOWS
(TYPICAL)
A18
CG1
CG1
ADA
THRESHOLD
(TYPICAL)
FD
FD
Ø
STAINLESS
STEEL COUNTER
AND SINK
C3
S1
WP1
CG1
S1
208A
203A
208C
C
L
BEDROOM
BATH
208A
C L
O S
E T
A
10'-0 1/4" 6" 3'-0"
EXISTING
CONDUITS
EXISTING
SHAFT
1'-10"
WC
LAV
SHOWER
A01
A14
A06
S1
S2
S2
C3
A2
SAFETY GLAZING SECURITY FILM - INSTALL
ON INSIDE FACE OF EXISTING GLAZING
ALIGN WALL
WITH EXISTING
SHAFT
C L
O S
E T
TV
A18
CG1
SERVICE SINK
S1
FD
FD
ADA MARBLE
THRESHOLD
(TYPICAL)
C3
4'-0"
WP2
WP3
WP1
WP1
WP3
257A
256C
256A
257C
C22 C32
C
L
C
L
257A
256C
256A
257C
BATH
256A
BEDROOM
BATH
257A
BEDROOM
EQUIPMENT
STORAGE
TOILET
13'-8 1/2" 16'-4 1/2"2'-11 1/4"5'-0"
2'-10"
WC
WC
LAV
LAV
SHOWER
SHOWER
A01
A14
A06
A01
A14
A06
S1
S1
S2
S2
C3
C3
A3
A3
A2
SAFETY GLAZING SECURITY FILM - INSTALL
ON INSIDE FACE OF EXISTING GLAZING
5'-0"
7'-7"
C L O
S E
T
C L
O S
E T
TV
TV
A18
A18
A18
S1
CG1
CG1
WP3
WP1
A18
LAV
FDFD
FD
FEC
ADA THRESHOLD
(TYPICAL)
REFERENCE
DETAIL F7/AE501
FD
FD
STORAGE
C3
WP1
WP1
WP3
WP3
C
A
C
245A
C
L
C
L 245
C
A
C
BATH
245A
SUITE
PASSAGE
C35
BEDROOM-
BARIATRIC
BEDROOM
SE
PARLOR/DEN
HAC
STOR.
SUITE
PASSAGE
C34
3'-0"
13'-3 1/4"
ALIGN
EXISTING
SHAFT
BATH
243A
A01
A14
A01
A14
A06
A06
LAV
LAV
WC
WC
SHOWER
C4
C2
C4
C4
C4
C3
C3
C3
A3
C3
C3
SAFETY GLAZING
SECURITY FILM -
INSTALL ON INSIDE
FACE OF EXISTING
GLAZING
8'-0"
HOLD
3'-11 1/2" 4'-0 1/2" 9'-0 3/4"
5'-4" 7'-0 1/2" 4'-4 1/4"
7'-6 1/4"
1'-0"
SHOWER
5'-7"
C5
CLOSET
CLOSET
TV
PROVIDE PRIVACY FILM
ON ALL BATHROOM
WINDOWS (TYPICAL)
A18
A18
CG1
EG
CG1
CG1
CG1
CG1
CG1
CG1
CG1
FD
FD
C5
FD
FD
TV
ADA THRESHOLD
(TYPICAL) REFERENCE
DETAIL F7/AE501
5'-8"
WP1
WP3
WP3
WP1
WP1
WP3
WP2
FEC
Ø
CG1
CG1
CG1
CG1
Ø
A12
A01
A21
PLASTIC LAMINATE
A11
A05
A20
3'-0"
SHOWER WIDTH
6"
A09
A03
A06
A10
A18
EQUAL EQUAL
A10
A07
A05
A11
A09
A06
A14
A08
A02
A15
A21
A13
3'-0"2'-0"
A18
3'-0" SHOWER WIDTH
6"
A11
A05
A20
A12
3'-0"
SHOWER WIDTH
6"
A01
EXISTING
WINDOW
PRIVACY
WINDOW
FILM
A21
PLASTIC
LAMINATE
SIDE PANEL
A14
A08
A02
A21
A06
A07
A05
A10
A11
A09
3'-0" 2'-0"
3'-0"
SHOWER WIDTH
6"
A18
A03
A06
A09
A10
A18
EQUAL EQUAL
A14
A08
A02
A21
A10
A05
A20
3'-0"
2'-0"
3'-0"
SHOWER WIDTH
6"
A09
A03
A10
A06
A18
EQUAL EQUAL
A10
A11
A07
A05
A12
A09
A06
A18
A01
EXISTING WINDOW WITH NEW
PRIVACY WINDOW FILM
A21
A10
A11
A07
A05
A12
A20
3'-0"
SHOWER WIDTH
6"
A01
A21
A10
A05
A14
A08
A02
A06
A09
A21
4'-0"
2'-0" A18
A06
A03
A09
A10
A18
EQUAL EQUAL
A10
A11
A07
A05
A09
A06
A20
A18
A09
A03
A10
A06
A18
EQUAL EQUAL
A14
A08
A02
A21
A10
A05
3'-0" 2'-0"
EXISTING
WINDOW
PRIVACY
WINDOW
FILM
A01
A12
A21
A15
A16
A12
A01
A21
A10
A11
A07
A05
A09
A06
A14
A08
A02
A21
3'-0"2'-0"
A18
A09
A03
A10
A06
A18
EQUAL EQUAL
A10
A05
A19
EXISTING
WINDOW
PRIVACY
WINDOW FILM
6"
3'-0" SHOWER WIDTH
3'-0"
A08
A02
A21
A08
A02
A21
A01
A12
A21
PLASTIC
LAMINATE SIDE
PANEL
A05
A18
A12
A09
A03
A18
A07
A01
A02
HAND WASH LAVATORY
BASE
REFER TO FINISH
SCHEDULE
CLINICAL
SINK
STAINLESS STEEL
COUNTERTOP WITH
INTEGRAL BACKSPLASH
REFER TO PLUMBING
STAINLESS STEEL
SHELF
SSOE, Inc.
Project #
Troy, MI 48084
Suite 260
T 248-643-6222
1050 Wilshire Drive
015-02007-00
SCHEMATIC SUBMISSION - NOT FOR CONSTRUCTION
100% BID DOCUMENT SUBMISSION
95% CONSTRUCTION DOCUMENTS
DESIGN DEVELOPMENT - NOT FOR CONSTRUCTION
SCHEMATIC DESIGN_REV, MOD P00001 SUBMISSION
95% CONSTRUCTION DOCUMENTS SUBMISSION
NOT FOR CONSTRUCTION
SECOND FLOOR ENLARGED PLAN
1/4" = 1'-0"AE121
C1
NORTH
SECOND FLOOR ENLARGED PLAN
1/4" = 1'-0"AE121
B2
C2
C1 AE503
C1AE503
C3 AE503
C3 AE503
C1
AE503
AE503
BATHROOM 208A
1/4" = 1'-0"AE422
D5
D6
E5
E6
BATHROOM 227A
B5
C5
C6
BATHROOM 257A
D7
BATHROOM 257A
D8
E7
E8
BATHROOM 256A
B7
B8
C7
C8
B5
E2
D2
E1D1 AE422
E4
D4
E3D3 AE422
E6
D6
E5D5 AE422
C6
B6
C5B5 AE422
E8
D8
E7D7 AE422
C8
B8
C7B7 AE422
B1
AE510
B1
AE510
B1
AE510
B1
F4 AE422
BATHROOM 243A
D1
D2
E1
E2
BATHROOM 245A
D4
BATHROOM 245A
E4
B1
AE510
B1
AE510
F8
F6
F7F5 AE422
TOILET 258
F5
F7
F8
GENERAL CONSTRUCTION NOTES
AE501
SOILED UTL/HOLDING 228
F4
F4
AE502
F4
AE502
C1
AE510
ABBREVIATIONS:
C/C CONTRACTOR FURNISHED/CONTRACTOR INSTALLED
V/C VA FURNISHED/CONTRACTOR INSTALLED V/V VA FURNISHED/ VA INSTALLED
BATHROOM ACCESSORY LEGEND
ID # DESCRIPTION
PROVIDED/
INSTALLED
BLOCKING
REQUIRED
A01
DISPENSER, PAPER TOWEL, STAINLESS STEEL, SURFACE
MOUNTED
V/C YES
A02
DISPENSER, SOAP
V/C NO
A03
42" GRAB BAR, 1 1/4" DIAMETER STAINLESS STEEL, WHEELCHAIR
ACCESSIBLE
C/C YES
A04
36" GRAB BAR, 1 1/4" DIAMETER STAINLESS STEEL, WHEELCHAIR
ACCESSIBLE
C/C YES
A05
24" GRAB BAR, 1 1/4" DIAMETER, WHEELCHAIR ACCESSIBLE
C/C YES
A06
24" UP-SWINGING GRAB BAR, 1 1/4" DIAMETER, STAINLESS
STEEL, WHEELCHAIR ACCESSIBLE
C/C YES
A07
18" VERTICAL GRAB BAR, 1 1/4" DIAMETER STAINLESS STEEL
C/C YES
A08
MIRROR, FLOAT GLASS, WITH WOOD FRAME (18"W X 30" H)
C/C NO
A09 NURSE CALL C/C NO
A10
ROD, SHOWER, WITH CURTAIN
C/C NO
A11
SHOWER, HANDHELD
C/C NO
A12
HOOK, GARMENT, DOUBLE
C/C YES
A13 NOT USED - -
A14 RECESSED CABINET C/C YES
A15 NOT USED
A16 NOT USED - -
A17
MEDICINE CABINET, REFER TO DETAIL F3/AE502 UNLESS NOTED
OTHERWISE.
- YES
A18 TOILET TISSUE DISPENSER C/C YES
A19 24" TOWEL BAR C/C YES
A20 36" TOWEL BAR C/C YES
A21 WALL MOUNTED VANITY FIXTURE REFER TO EL121 C/C NO
FLOOR PLAN LEGEND
PARTITION TYPE - PARTITION IS
TYPE "A" UNLESS OTHERWISE
NOTED. REFER TO SHEET GI100
FOR DETAILS
XX
DOOR NUMBER
ROOM NAME
REFER TO AE421, AE422,
AE423, AND AE424 FOR
ELEVATIONS
CORNER GUARD- REFER TO
AE502 FOR DETAILS
END GUARD- REFER TO AE502
FOR DETAILS
CG1
EG
FIRE EXTINGUISHER CABINET
REFER TO SPECIFICATIONS
FEC
EXISTING WALL
NEW WALLS
PATIENT BED CENTERLINE
C
L
FD
FLOOR DRAIN
WALL PROTECTION. REFER TO
DETAIL B9/AE502
WP1
WALL PROTECTION. REFER TO
DETAIL C9/AE502
WP2
WALL PROTECTION. REFER TO
DETAIL B8/AE502
WP3
1. DO NOT SCALE DRAWINGS. WORK FROM DIMENSIONS SHOWN. IF ADDITIONAL INFORMATION
IS NEEDED, OR WHERE DRAWINGS OR DRAWING SCALE APPEAR TO CONFLICT WITH
INDICATED DIMENSIONS, BRING TO THE ATTENTION OF THE ARCHITECT FOR REVIEW.
2. COORDINATE SCHEDULE OF OVERALL CONSTRUCTION AND DAY-TO-DAY CONSTRUCTION
OPERATIONS WITH OWNER'S SCHEDULE REQUIREMENTS.
3. FLOOR PLAN DRAWINGS ARE COMPOSITES OF EXISTING CONSTRUCTION TO REMAIN AND
NEW CONSTRUCTION. EXISTING CONSTRUCTION IS SHOWN IN LIGHTER, OUTLINE FORM.
NEW CONSTRUCTION IS INDICATED WITH HEAVIER LINEWORK AND MAY ADDITIONALLY BE
IDENTIFIED BY NOTE, KEYNOTE, LARGER SCALE DETAIL REFERENCE, OR MATERIAL PATTERN
(REFER ALSO TO LEGEND).
4. ALL WALL DIMENSIONS ARE TO FINISH FACE OF WALL UNLESS NOTED OTHERWISE
5. DOCUMENTS ARE BASED ON VA'S RECORD DRAWINGS AND LIMITED FIELD SURVEY. FIELD
VERIFY ALL PROJECT CONDITIONS PRIOR TO THE START OF, AND AS NEEDED DURING THE
COURSE OF, NEW CONSTRUCTION WORK. BRING ANY DISCREPANCIES WHICH MAY
SIGNIFICANTLY AFFECT NEW CONSTRUCTION WORK TO THE ATTENTION OF THE ARCHITECT
FOR REVIEW.
6. KEEP MEANS OF EGRESS OPEN, PROPERLY ILLUMINATED, AND FREE OF OBSTRUCTIONS AT
ALL TIMES.
7. WHERE NEW WALL CONSTRUCTION ABUTS EXISTING, IN-LINE, ON PLANS, DIRECTLY ALIGN
NEW FINISH WALL SURFACE(S) WITH EXISTING.
8. ALL WOOD BLOCKING AND BACKING SHALL BE FIRE-RETARDANT TREATED, UNLESS NOTED
OTHERWISE.
9. KEEP CONSTRUCTION NOISE TO A MINIMUM.
10. NO SMOKING IS ALLOWED INSIDE THE EXISTING BUILDING, INCLUDING AT THE
CONSTRUCTION AREA.
11. PATCH AND REPAIR DENTS, CRACKS, HOLES, AND/OR OTHER UNEVEN SURFACE CONDITIONS
IN EXISTING CONSTRUCTION TO REMAIN.
12. VERIFY THE DIMENSIONS, LOCATIONS, ELEVATIONS AND ARRANGEMENT OF ALL ITEMS
ASSOCIATED WITH INSTALLATION OF EQUIPMENT AND RELATED MECHANICAL AND
ELECTRICAL WORK.
13. NOTIFY THE OWNER AND ARCHITECT OF ANY CODE AND/OR CONSTRUCTION DEFICIENCIES
DISCOVERED OR UNCOVERED IN THE COURSE OF CONSTRUCTION OPERATIONS.
14. THE EXISTING BUILDING, AND ITS SUBSEQUENT CONSTRUCTION MODIFICATIONS, ARE
ASSUMED TO BE IN FULL COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS IN
EFFECT AT THE TIME OF CONSTRUCTION.
15. PATCH EXISTING FLOOR OPENINGS AFTER DEMO OF EXISTING MECHANICAL AND PLUMBING
SHAFTS. REFER TO DETAIL F1/AE503.
16. ALL WALLS SHALL EXTEND TO DECK ABOVE, UNLESS NOTED OTHERWISE. REFER TO TYPICAL
WALL TYPES.
17. WHERE EXISTING WALLS ARE INDICATED AS RATED WALLS, SEAL ALL PENETRATIONS AND
OPENINGS WITH FIRE STOPPING TO MAINTAIN INDICATED RATING. FIELD VERIFY.
18.EXISTING FLOOR IS FIRE RATED. SEAL ALL PENETRATIONS AND OPENINGS WITH FIRE
STOPPING TO MAINTAIN INDICATED RATING.
19.PROVIDE TEMPORARY DUST PARTITIONS AT FIRST AND SECOND FLOOR AND OTHER
OCCUPIED AREAS AS REQUIRED BY CONSTRUCTION WORK. REFER TO TYPICAL DETAILS ON
DRAWING.
20.PROVIDE BLOCKING/METAL SUPPORT STRAPS IN PARTITIONS FOR EQUIPMENT INSTALLATION
(I.E. GRAB BARS, TV MONITORS ETC.) REFER TO DRAWINGS FOR LOCATIONS.
21.VERIFY AND COORDINATE CLEAR CHASE SPACE REQUIREMENTS WITH WALL LOCATIONS FOR
WATER CLOSET AT EACH TOILET AND MECHANICAL AND ELECTRICAL. DUCTS, CONDUITS AND
PIPING WITH EXISTING STRUCTURE AND EXISTING UTILITIES BELOW. CHASE WALL
LOCATIONS SHALL BE ADJUSTED AS REQUIRED TO ALLOW FOR PROPER INSTALLATION
THROUGH EXISTING STRUCTURAL CONCRETE FLOOR SLAB. NOTIFY ARCHITECT PRIOR TO
PROCEEDING. EXISTING UTILITIES BELOW MAY HAVE TO BE REWORKED FOR NEW
CONSTRUCTION.
22. PROVIDE CEMENT BOARD AT ALL SHOWERS AND WET WALLS, TYPICAL.
23. EXISTING CLAY TILE AND PLASTER COLUMN AND STEAM PIPING ENCLOSURE TO REMAIN AT
EXTERIOR WALL COLUMNS. VERIFY EACH LOCATION. REPORT ANY DISCREPANCY TO
ARCHITECT.
24. REFER TO SHEET AE431, AE501 FOR TYPICAL BUILT-UP BATHROOM FLOOR INFORMATION.
25. REFER TO SHEET IN102 FOR TYPICAL WALL TILE LAYOUT DESIGN IN RESIDENT BATHROOMS.
A4
AE502
E1
AE502
A6
AE502
XXX
C2
AE502
http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com
252A
C
C
C
254A
253A
CHARTING
BEDROOM
SW
PARLOR/DEN
BEDROOM
HAC
CLEAN
LINEN
BEDROOM-
BARIATRIC
SUITE
PASSAGE
C38
CORRIDOR
C37
C37
252A
C
C
C
254A
253A
S2-3
F
E
C
C
L
C
L
C
L
Ø
2'-1" 5'-0" 2'-11"
2'-4"
4'-5"
3'-0"
4'-9" 5'-0"
WC
LAV
SHOWER
WC
LAV
LAV
WC
SHOWER
EXISTING
SHAFT
EXISTING
SHAFT
1'-10"
WALL
MOUNTED
CHARGING
STATION
A01
A14
A06
A06
A01
A14
A06
A01
A14
SAFETY GLAZING SECURITY FILM - INSTALL
ON INSIDE FACE OF EXISTING GLAZING
C4
C3
C3
C3
C3
C3
C3
B1
B1
A1
A3
A2
A
A
BATHROOM
BARIATRIC
252A
BATHROOM
253A
10'-4 3/4"
6'-8 1/4" 4'-9" 3'-0"
BATHROOM
254A
6'-5 3/4"
4'-11"
ALIGN WALL WITH
COLUMN FURRING
TV
TV
BATHROOM
254A
PROVIDE PRIVACY
FILM ON BATHROOM
WINDOWS (TYPICAL)
CLOSET
CLOSET
CLOSET
A18
A18
A18
CG1
CG1
CG1
CG1
CG1
CG1
CG1
TV
FD
C3
FD
FD
FD
FD
C2
C3
CG1
CG1
EG-1
WP3
4'-0"
SERVICE SINK
RE: PLUMBING
ADA THRESHOLD
(TYPICAL)
C3
ADA THRESHOLD
(TYPICAL)
REFERENCE
DETAIL F7/AE501
ADA THRESHOLD
(TYPICAL)
REFERENCE
DETAIL E7/AE501
Ø6'-4"
WP1
WP1
WP1
WP3
WP3
WP3
WP3
WP3
NORTH
A14
A08
A02
A21
A10
A05
A20
3'-0" 2'-0"
6"
3'-0" SHOWER WIDTH
BASE
REFER TO FINISH
SCHEDULE
SOUTH
A06
A09
A03
A10
A18
EQUAL EQUAL
BASE
REFER TO FINISH
SCHEDULE
A10
A11
A07
A05
A12
A06
A09
A18
BASE
REFER TO FINISH
SCHEDULE
STOP SIDESPLASH AT
WINDOW FRAME
PLASTIC LAMINATE SIDE
PANEL
EXISTING WINDOW WITH
NEW PRIVACY WINDOW
FILM AND SAFETY
GLAZING SECURITY FILM
A01
A21
BASE
REFER TO FINISH
SCHEDULE
A01
A12
2'-0"
PLASTIC
LAMINATE
SIDE PANEL
A21
A06
A09
A05
A10
A11
A18
A03
A09
A10
A06
EQUAL EQUAL
A14
A08
A02
A21
A11
A05
A20
2'-0" 3'-0"
NORTH
A01
A12
1'-6"
A21
BASE
REFER TO FINISH
SCHEDULE
EAST SOUTH
A03
A09
A10
EQUAL EQUAL
BASE
REFER TO FINISH
SCHEDULE
A06
A20
A10
A07
A18
3'-0" SHOWER WIDTH
6"
BASE
REFER TO FINISH
SCHEDULE
A14
A08
A02
A21
A09
A06
2'-0" 3'-0"
BASE
REFER TO FINISH
SCHEDULE
234A
234A
C
236C
236A
F E
C
C
L
234A
LOCKER
ROOM
BEDROOM
BATH
236A
SHOWER RM
STAFF
TOILET
234A
CORRIDOR
C30
12'-0 1/2"9'-4"
WC
LAV
SHOWER
A01
A14
EXISTING
SHAFT
A06
WC
LAV
2'-8"
S1
S1
S2
S2
C3
A2
S2
A3
A3
SAFETY GLAZING
FILM
EXISTING
SHAFT
ALIGN WALL WITH
EXISTING SHAFT
ALIGN WALL WITH
EXISTING SHAFT
10'-8 1/2"
COAT HOOKS
C L
O S
E T
PROVIDE PRIVACY
FILM ON TOILET
ROOM WINDOW
A18
CG1
CG1
CG1
CG1
10'-10 1/4" 10'-1 3/4"
ADA THRESHOLD
(TYPICAL) REFER TO
DETAIL F7/AE501
TV
FD
FD
FD
FD
ADA THRESHOLD
(TYPICAL) REFER
TO DETAIL
F7/AE501
PRIVACY
CURTAIN AND
TRACK
A01
A4
S1
LOCKERS
LAV
FD
EQ EQ
SHOWER
CONTROLS
Ø
Ø
WP1
8'-0" 8'-7 1/2"
WP2
WP3
WP3
A2
A03
A09
A10
A18
EQUAL EQUAL
A10
A11
A07
A05
A20
6"
3'-0" SHOWER WIDTH
A12
A01
PLASTIC
LAMINATE
SIDE PANEL
A14
A08
A02
A21
A10
A05
A09
A06
3'-0" 2'-0"
A18
WALL
TILE
1'-9" 2'-8 3/4" 1'-9"
A02
A21
A08
FINISHED
END PANEL
BASE - REFER TO
FINISH SCHEDULE
GYPSUM BOARD
CEILING DROP
A12
A11
A07
A03
EQ
A01
EQ
WALL
TILE
A06
BASE
REFER TO FINISH
SCHEDULE
A18
WALL
TILE
A09
A06
WALL
TILE
A18
A01
A12
SCHEDULED BASE
EXISTING WINDOW WITH
NEW PRIVACY WINDOW FILM
A07
A03
A06
A18
A08
A02
A21
A02
NEW PRIVACY WINDOW FILM
METAL LOCKERS
REFER TO AE503
SLOPED TOP
BASE
REFER TO FINISH
SCHEDULE
ADJUSTABLE
COUNTER BY OWNER
HAT AND
COAT
HOOKS
BASE
REFER TO
FINISH
SCHEDULE
LOCKERS
SSOE, Inc.
Project #
Troy, MI 48084
Suite 260
T 248-643-6222
1050 Wilshire Drive
015-02007-00
SCHEMATIC SUBMISSION - NOT FOR CONSTRUCTION
100% BID DOCUMENT SUBMISSION
95% CONSTRUCTION DOCUMENTS
DESIGN DEVELOPMENT - NOT FOR CONSTRUCTION
SCHEMATIC DESIGN_REV, MOD P00001 SUBMISSION
95% CONSTRUCTION DOCUMENTS SUBMISSION
NOT FOR CONSTRUCTION
F1
C1AE503
C3AE503
AE503
BATHROOM 252A
1/4" = 1'-0"AE423
G3
G4
BATHROOM 253A
BATHROOM 253A
BATHROOM 254A
A3
A4
B3
B4
E4
D4
E3D3 AE423
B4
A4
B3A3 AE423
G4
F4
G3F3 AE423
B2
AE423
B1
AE510
B1
AE510
B1
AE510
B3,D3
AE501
B3,D3
B6
G8
F8
G7F7 AE423
C3AE503
E5D5
D6
AE423
BATHROOM 236A
F8
G7 BATHROOM 236A
G8
SHOWER 235
D5
D6
E6
AE511
STAFF TOILET 234A
G5
G6
LOCKER ROOM 234
E8
D8
E8
AE423
F5 G5
G6
F6
AE423
GENERAL CONSTRUCTION NOTES
CHARTING 250
B2
F8
AE510
B1
AE510
B6
TYPICAL
LOCKER ROOM 234
D8
F1
AE501
F4
AE502
E5
AE503
ABBREVIATIONS:
C/C CONTRACTOR FURNISHED/CONTRACTOR INSTALLED
V/C VA FURNISHED/CONTRACTOR INSTALLED V/V VA FURNISHED/ VA INSTALLED
BATHROOM ACCESSORY LEGEND
ID # DESCRIPTION
PROVIDED/
INSTALLED
BLOCKING
REQUIRED
A01
DISPENSER, PAPER TOWEL, STAINLESS STEEL, SURFACE
MOUNTED
V/C YES
A02
DISPENSER, SOAP
V/C NO
A03
42" GRAB BAR, 1 1/4" DIAMETER STAINLESS STEEL, WHEELCHAIR
ACCESSIBLE
C/C YES
A04
36" GRAB BAR, 1 1/4" DIAMETER STAINLESS STEEL, WHEELCHAIR
ACCESSIBLE
C/C YES
A05
24" GRAB BAR, 1 1/4" DIAMETER, WHEELCHAIR ACCESSIBLE
C/C YES
A06
24" UP-SWINGING GRAB BAR, 1 1/4" DIAMETER, STAINLESS
STEEL, WHEELCHAIR ACCESSIBLE
C/C YES
A07
18" VERTICAL GRAB BAR, 1 1/4" DIAMETER STAINLESS STEEL
C/C YES
A08
MIRROR, FLOAT GLASS, WITH WOOD FRAME (18"W X 30" H)
C/C NO
A09 NURSE CALL C/C NO
A10
ROD, SHOWER, WITH CURTAIN
C/C NO
A11
SHOWER, HANDHELD
C/C NO
A12
HOOK, GARMENT, DOUBLE
C/C YES
A13 NOT USED - -
A14 RECESSED CABINET C/C YES
A15 NOT USED
A16 NOT USED - -
A17
MEDICINE CABINET, REFER TO DETAIL F3/AE502 UNLESS NOTED
OTHERWISE.
- YES
A18 TOILET TISSUE DISPENSER C/C YES
A19 24" TOWEL BAR C/C YES
A20 36" TOWEL BAR C/C YES
A21 WALL MOUNTED VANITY FIXTURE C/C NO
FLOOR PLAN LEGEND
PARTITION TYPE - PARTITION IS
TYPE "A" UNLESS OTHERWISE
NOTED. REFER TO SHEET GI100
FOR DETAILS
XX
DOOR NUMBER
ROOM NAME
REFER TO AE421, AE422,
AE423, AND AE424 FOR
ELEVATIONS
CORNER GUARD- REFER TO
AE502 FOR DETAILS
END GUARD- REFER TO AE502
FOR DETAILS
CG1
EG
FIRE EXTINGUISHER CABINET
REFER TO SPECIFICATIONS
FEC
EXISTING WALL
NEW WALLS
PATIENT BED CENTERLINE
C
L
FD
FLOOR DRAIN
WALL PROTECTION. REFER TO
DETAIL B9/AE502
WP1
WALL PROTECTION. REFER TO
DETAIL C9/AE502
WP2
WALL PROTECTION. REFER TO
DETAIL B8/AE502
WP3
1. DO NOT SCALE DRAWINGS. WORK FROM DIMENSIONS SHOWN. IF ADDITIONAL INFORMATION
IS NEEDED, OR WHERE DRAWINGS OR DRAWING SCALE APPEAR TO CONFLICT WITH
INDICATED DIMENSIONS, BRING TO THE ATTENTION OF THE ARCHITECT FOR REVIEW.
2. COORDINATE SCHEDULE OF OVERALL CONSTRUCTION AND DAY-TO-DAY CONSTRUCTION
OPERATIONS WITH OWNER'S SCHEDULE REQUIREMENTS.
3. FLOOR PLAN DRAWINGS ARE COMPOSITES OF EXISTING CONSTRUCTION TO REMAIN AND
NEW CONSTRUCTION. EXISTING CONSTRUCTION IS SHOWN IN LIGHTER, OUTLINE FORM.
NEW CONSTRUCTION IS INDICATED WITH HEAVIER LINEWORK AND MAY ADDITIONALLY BE
IDENTIFIED BY NOTE, KEYNOTE, LARGER SCALE DETAIL REFERENCE, OR MATERIAL PATTERN
(REFER ALSO TO LEGEND).
4. ALL WALL DIMENSIONS ARE TO FINISH FACE OF WALL UNLESS NOTED OTHERWISE
5. DOCUMENTS ARE BASED ON VA'S RECORD DRAWINGS AND LIMITED FIELD SURVEY. FIELD
VERIFY ALL PROJECT CONDITIONS PRIOR TO THE START OF, AND AS NEEDED DURING THE
COURSE OF, NEW CONSTRUCTION WORK. BRING ANY DISCREPANCIES WHICH MAY
SIGNIFICANTLY AFFECT NEW CONSTRUCTION WORK TO THE ATTENTION OF THE ARCHITECT
FOR REVIEW.
6. KEEP MEANS OF EGRESS OPEN, PROPERLY ILLUMINATED, AND FREE OF OBSTRUCTIONS AT
ALL TIMES.
7. WHERE NEW WALL CONSTRUCTION ABUTS EXISTING, IN-LINE, ON PLANS, DIRECTLY ALIGN
NEW FINISH WALL SURFACE(S) WITH EXISTING.
8. ALL WOOD BLOCKING AND BACKING SHALL BE FIRE-RETARDANT TREATED, UNLESS NOTED
OTHERWISE.
9. KEEP CONSTRUCTION NOISE TO A MINIMUM.
10. NO SMOKING IS ALLOWED INSIDE THE EXISTING BUILDING, INCLUDING AT THE
CONSTRUCTION AREA.
11. PATCH AND REPAIR DENTS, CRACKS, HOLES, AND/OR OTHER UNEVEN SURFACE CONDITIONS
IN EXISTING CONSTRUCTION TO REMAIN.
12. VERIFY THE DIMENSIONS, LOCATIONS, ELEVATIONS AND ARRANGEMENT OF ALL ITEMS
ASSOCIATED WITH INSTALLATION OF EQUIPMENT AND RELATED MECHANICAL AND
ELECTRICAL WORK.
13. NOTIFY THE OWNER AND ARCHITECT OF ANY CODE AND/OR CONSTRUCTION DEFICIENCIES
DISCOVERED OR UNCOVERED IN THE COURSE OF CONSTRUCTION OPERATIONS.
14. THE EXISTING…