36C25018B0803-027.pdf

PDF 15 MB Posted

Attached to
Renovate Building 83-2 515-14-108 Federal contract opportunity
Solicitation number
36C25018B0803
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10

About this file

36C25018B0803 515-14-108 Battle Creek 83-2 Patient Privacy BID Drawings_Part2.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Renovate Building 83-2 515-14-108, newest first.
File Type Posted
36C25018B0803-0005000.docx DOCX document
36C25018B0803-0005001.pdf PDF
36C25018B0803-0003001.pdf PDF
36C25018B0803-0003000.docx DOCX document
36C25018B0803-0002003.zip ZIP file
36C25018B0803-025.pdf PDF
36C25018B0803-024.pdf PDF
36C25018B0803-026.pdf PDF
36C25018B0803-022.docx DOCX document
36C25018B0803-023.pdf PDF
36C25018B0803-000.docx DOCX document
Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NORTH

SECOND FLOOR ASBESTOS ABATEMENT PLAN

1/8" = 1'-0"HA121

F4

100% BID DOCUMENT SUBMISSION

FD

SSOE, Inc.

Project #

Troy, MI 48084

Suite 260

T 248-643-6222

1050 Wilshire Drive

015-02007-00

FULLY SPRINKLERED

100% BID DOCUMENT SUBMISSION

COMPLETION ITEM NO.

95% CONSTRUCTION DOCUMENTS

DESIGN DEVELOPMENT - NOT FOR CONSTRUCTION

95% CONSTRUCTION DOCUMENTS SUBMISSION

NOT FOR CONSTRUCTION

NORTH

GENERAL DEMOLITION NOTES:

1. COORDINATE DEMOLITION WORK WITH HAZARDOUS MATERIAL ABATEMENT CONTRACTOR

2. BUILDING STRUCTURE TO REMAIN, UNLESS NOTED OTHERWISE REMOVE FINISHES ON COLUMNS IN AREA OF WORK WHERE DEMOLITION IS

SHOWN AND PROTECT FROM DAMAGE DURING DEMOLITION PHASE.

3. PROVIDE ALL DEMOLITION WORK SHOWN ON THE DRAWINGS AND ALL RELATED AND INCIDENTAL DEMOLITION WORK REQUIRED. ALSO REFER TO

MEP/FP/FA DRAWINGS FOR SCOPE OF MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION AND FIRE ALARM DEMOLITION SCOPE OF WORK.

4. REMOVE CABINETRY, CASEWORK AND MILLWORK IN AREA OF WORK FROM ROOMS SCHEDULED TO UNDERGO RENOVATION. COORDINATE

FURNITURE MOVES WITH OWNER. STORE ALL APPROVED FURNITURE AND EQUIPMENT IN SECURED AREA AS DESIGNATED BY OWNER.

5. REMOVE TRIM AT CEILINGS, WINDOWS, DOORS, AND BASES IN AREA OF WORK.

6. REMOVE DOORS, GLAZING AND FRAMES FROM BUILDING INTERIORS IN AREA OF WORK.

7. REMOVE CERAMIC TILE IN AREA OF WORK.

8. REMOVE INTERIOR PARTITIONS AT TYPICAL ROOMS AND ALL INTERIOR MASONRY AT DUCT AND MISCELLANEOUS SHAFTS IN AREA OF WORK.

NOTIFY COR AND ARCHITECT OF UNEXPECTED CONDITIONS ENCOUNTERED.

9. REMOVE FINISH CEILINGS AND SUSPENSION SYSTEMS IN AREA OF WORK.

10.PRESERVE EXISTING FURRED WALL AND INSULATION AT EXTERIOR WALL, UNLESS NOTED OTHERWISE. REMOVE EXISTING WALL FINISH, AND

PREP WALL SURFACE FOR NEW FINISH.

11. UPON REMOVAL OF FINISH MATERIALS INDICATED OR REQUIRED, PREPARE SUBSTRATE TO RECEIVE NEW FINISH. REPAIR ANY EXISTING

DAMAGE, OR DAMAGE ARISING FROM DEMOLITION OPERATIONS TO MATCH EXISTING ADJACENT CONSTRUCTION.

12. PATCH AND REPAIR ALL DAMAGE ARISING FROM DEMOLITION OPERATIONS TO FLOOR, WALL AND CEILING SURFACES, TO MATCH EXISTING

ADJACENT CONSTRUCTION. PATCH ALL SPALLED CONCRETE CAUSED BY PARTITION REMOVAL. REMOVE ANY EXTRANEOUS MATERIAL AND PATCH

ANY DEPRESSIONS IN EXISTING SURFACES TO REMAIN.

13. REMOVE FLOOR BASE IN AREA OF WORK.

14.PATCH FLOOR OPENING WHERE EXISTING CONDUIT, PIPING, AND DUCT WORK ARE REMOVED AS DIRECTED. REFER TO STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. REFER TO DETAIL F1/AE503 FOR FILL-IN DETAIL.

15.FIELD VERIFY ALL EXISTING CONDITIONS, PRIOR TO START OF DEMOLITION OPERATIONS. BRING ANY DISCREPANCIES WHICH MAY SIGNIFICANTLY

AFFECT DEMOLITION TO THE ATTENTION OF THE COR FOR REVIEW.

16.PROTECT EXISTING CONSTRUCTION TO REMAIN FROM DAMAGE DURING DEMOLITION AND/OR CONSTRUCTION OPERATIONS.

17.DO NOT ALTER THE STRUCTURAL INTEGRITY OF THE EXISTING BUILDING OR ITS ASSEMBLIES UNLESS SPECIFICALLY NOTED OTHERWISE.

18.MAINTAIN EXIT ACCESS WAYS, AND KEEP FULLY SEPARATED FROM CONSTRUCTION AREA, AT ALL TIMES.

19.COORDINATE TIMING OF HOURS OF DEMOLITION OPERATIONS WITH THE OWNER.

20.COORDINATE START OF DEMOLITION OPERATIONS WITH THE OWNER.

21.ALL HVAC DUCT OPENINGS SHALL BE COMPLETELY SEALED TO PREVENT AIR MOVEMENT TO OR FROM THE CONSTRUCTION AREA VIA THE

BUILDING HVAC SYSTEM.

22.ANY EXISTING LIGHT FIXTURES BEING REMOVED PER DRAWINGS SHALL BE SALVAGED, AND RETURNED TO THE OWNER.

23.REFER TO INFECTION CONTROL INFORMATION IN SPECIFICATIONS.

24.PROVIDE TEMPORARY FILTERS TO PREVENT THE SPREAD OF DUST THROUGH THE BUILDING VIA THE RETURN AIR SYSTEM. UPON COMPLETION

OF DEMOLITION/CONSTRUCTION OPERATIONS, REMOVE BARRIERS AND REPAIR ANY DAMAGE CAUSED BY THEIR INSTALLATION OR PRESENCE TO

"LIKE NEW" CONDITION.

25. REMOVE EXISTING CEILING LIFTS AND TRACK SUPPORTS. RETURN TO THE OWNER.

26. REMOVE ALL WALL COVERINGS AND BORDERS. SKIM COAT WALL AND PREP SURFACES FOR NEW FINISHES.

27.REMOVE ALL SIGNAGE AND WALL HUNG ITEMS. PATCH AND REPAIR WALL. PREP WALL SURFACE FOR NEW FINISHES.

28. REMOVE EXISTING FIRE EXTINGUISHER CABINETS AND EXTINGUISHERS. RETURN TO THE OWNER.

29.REMODELING OR PATCHING SHALL BE EXECUTED IN CONJUNCTION WITH THE NEW WORK AND THE DEMOTION WORK IN THE DRAWINGS.

30.PATCH ALL EXPOSED INTERIOR FACES OF INTERIOR WALLS TO REMAIN WHERE ATTACHED OR IMBEDDED ITEMS WERE REMOVED. PATCH

COLUMN ENCLOSURES TO REMAIN WHERE INTERSECTING PARTITIONS WERE REMOVED.

31.THE CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARATION OF FLOORS, WALLS, COLUMN ENCLOSURES AND CEILINGS TO RECEIVE NEW

FINISHES.

32.PATCH AND PREPARE FLOOR WITH CONCRETE FLUSH WITH ADJACENT FLOOR SURFACE, FILL ANY SLOPING OR RECESSED AREAS LEVEL TO

TYPICAL FINISH FLOOR ELEVATION TO ACCOMMODATE NEW FLOOR FINISHES.

33.FILL IN EXISTING OPENINGS/PENETRATIONS IN WALLS, BULKHEADS, FLOOR OR ROOF DECK TO REMAIN, AS REQUIRED TO ENSURE INTEGRITY OF

EXISTING RATED SEPARATIONS. REFER TO DRAWING GI101 FOR REQUIRED RATINGS.

34.WHEN REMOVING DEBRIS FROM CONSTRUCTION AREA, WIPE OFF WHEELS BEFORE LEAVING CONSTRUCTION AREA AND USE WET RAGS OVER

DUMPSTER TO REDUCE DUST.

35.THE OWNER RESERVES THE RIGHT TO HALT CONSTRUCTION ACTIVITY AT ANY TIME DUE TO NOISE AND VIBRATION WHICH MIGHT EFFECT THE

OWNER'S ONGOING USE OF THE FACILITY.

36.PATCH TO MATCH ANY FIRE PROOF COATINGS ON STRUCTURAL STEEL DISTURBED DUE TO DEMOLITION WORK.

37.REFER TO WALL TYPE T-1 FOR TYPICAL DETAIL OF TEMPORARY CONSTRUCTION PARTITIONS.

DEMOLITION KEYNOTES

CONSTRUCTION TO REMAIN

ITEMS TO BE REMOVED

2 HOUR FIRE BARRIER WALL SHAFT

(EXISTING TO REMAIN)

EXISTING MECHANICAL SHAFTS TO REMAIN

X

XROOM NO. X X X X

EXISTING ITEMS TO BE REMOVED IN EACH

NUMBERED ROOM (ENTIRE SECOND FLOOR)

(EXCLUDING STAIRS & ELEVATOR)

X X

SECOND FLOOR DEMOLITION PLAN

1/8" = 1'-0"AE141

F3

NOTES

LEGEND

1 1

4 5 6

4 5 6

4 5 64 5 6

4 5 6

4 5 6

4 5 6

4 5 6

4 5 6

4 5 6

4 5 6

8 5 6

4 5 6

4 5 6

4 5 6

4 5 6

4 5 6

4 5 6

4 5 6

4 5 6

4 5 6

4 5 6 4 5 6

4 5 6

4 5 6

7 7

7 7 7 7

S4

RM.TREATMENT

DAY ROOM

NURSING

BED RM

KITCHEN

CLST

HKA

LINEN

BED RM

210B

STATION

203A

MED

C22

OFFICE

BED RM

STORAGE

STAIR

S3

BED RM

DAY ROOM

BED RM

BED RM

244A

VISITOR

OFFICE

CONFERENCE

STOR

C21

202A

221 228

CLST

BED RM

BED RM

TOILET

250A

LAUNDRY

TOILET

HSKP

TOILET

238B

BED RM

BED RM

S2

BED RM

TLT

BED RM

E

OFFICE

250B

TLT

TLT

224A

CLEAN LINEN

232A

OFFICE

235A

STORAGE

KITCHEN

WAIT

C25B

53sf

TLT

226A

OFFICE

SW

LOCKER RM

FP

STATION

NURSES

BATH/

SHOWER

TOILET

239A

BATH/

SHOWER

238A

TOILET

SHOWER

FAMILY

LOUNGE

PIPE

219E

TLT.

229A

BED RM

BED RM

TOILET

BT/SHW

210A

BED RM

BED RM

STRG.

234A

BED RM

STAIR

STAIR

STAIR

S1

2 5 8

4 5 6

2 5 8

2 5 8

4 5 62

4 5 62

4 5 62

2 5 8

TLT

233A

4 5 62

BED RM

4 5 62

4 5 62

4 5 62

2 5 8

2 5 8

236A

BTH/SHW

4 52

2 5 8

4 5 62

4 5 62

4 52

2 5 8

TLT

225A

2 5 8

2 5 8

8 52

2 5 8

5 8

REMOVE EXISTING DOOR AND FRAME. REMOVE DOOR HARDWARE AND KEYPADS AND RETURN TO OWNER.

REMOVE EXISTING INTERIOR PARTITION/CHASE INCLUDING DOORS, FRAMES, WINDOWS AND ALL ITEMS ON AND WITHIN WALL. CONCEALED

ITEMS IN EXISTING PARTITIONS/CHASES ARE UNKNOWN. CAREFULLY REMOVE PORTIONS OF EXISTING PARTITIONS FROM FLOOR TO DECK

ABOVE. NOTIFY COR AND ARCHITECT OF UNKNOWN CONDITIONS ENCOUNTERED. CONTINUE DEMOLITION AFTER APPROVAL FROM COR.

REMOVE EXISTING PLUMBING FIXTURE. REFER TO PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION

REMOVE EXISTING FLOOR FINISH AND WALL BASE, PATCH FLOOR, AND WALL SURFACES. PREPARE FLOOR AND WALL SURFACE FOR NEW

FLOOR FINISH - REFER TO FINISH SCHEDULE

REMOVE EXISTING CEILING SYSTEM AND ALL ASSOCIATED HANGERS AND SUPPORTS. REMOVE EXISTING BULKHEADS AND FRAMING. REFER

TO ELECTRICAL DEMO DRAWINGS FOR LIGHT FIXTURE DEMO INFORMATION.

REMOVE FURNITURE/LOOSE EQUIPMENT AND RETURN TO OWNER.

CAREFULLY REMOVE PORTIONS OF EXISTING WALL/COLUMN COVERS AS REQUIRED FOR NEW WORK.

REMOVE WALL AND FLOOR TILE. PREPARE SUBSTRATE TO RECEIVE NEW FINISH PER MANUFACTURER'S RECOMMENDATIONS.

REMOVE CASEWORK. PATCH WALL AND FLOOR SURFACES FOR NEW FINISHES.

DEDUCT ALTERNATE: EXISTING DOOR, FRAME AND HARDWARE TO REMAIN/BE REUSED. PREP DOOR SURFACE FOR NEW FINISH.

REMOVE INFILL PANEL AND MECHANICAL DEVICE FROM EXISTING UPPER WINDOW SASH.

DEMO EXISTING RADIATOR HEATERS AND DDS CONTROLS BACK TO CONTROL PANEL. REFER TO MECHANICAL DEMOLITION DRAWINGS FOR

MORE INFORMATION.

CONDUITS TO REMAIN.

12 12

1 HOUR FIRE PARTITION

REMOVE EXISTING 1ST FLOOR CEILING AND OTHER TRADES' CONSTRUCTION

(CARPENTRY, DUCTWORK, PLUMBING PIPES, AND CONDUITS) AS REQUIRED FOR 2ND

FLOOR WORK. VERIFY ALL AFFECTED 1ST FLOOR AREAS. AFTER THE COMPLETION OF

2ND FLOOR WORK, PATCH, REPAIR, REINSTALL CEILING AND OTHER TRADES'

CONSTRUCTION ON THE 1ST FLOOR AND RESTORE TO THEIR ORIGINAL CONDITION.

MATCH EXISTING FINISHES. CONTRACTOR TO COORDINATE ALL TRADES. CONTRACTOR

MUST VERIFY EXISTING CONDITION ABOVE 1ST FLOOR CEILING PRIOR TO BIDS.

EXISTING FIRST FLOOR REFLECTED CEILING

PLAN

EXISTING FIRST FLOOR REFLECTED

CEILING PLAN

W

D

F

E

C

FEC

F E

C

F E

C

F

E

C

C

L

C

L

C

L

C

L

C

L

C

L

C

L

C

L

C

L

C

L

C

L

C

L

C

L

C

L

C

L

Ø

FD

FIREPLACE

FIREPLACE

TV

NORTH

DINING

BEDROOM-

BARIATRIC

CHARTING

EXIST.

STAIR

S2-2

BATH

256A

BATH

245A

EXIST.

STAIR

S3-2

BEDROOM

NE

PARLOR/DEN

BATH

221A

BEDROOM

BATH

214A

MEDS/MED

SELECT

BATH

210A

BATH

253A

SUITE

PASSAGE

C25

UNIT

COORDINATOR

LOCKER

ROOM

BATH

254A

CHARTING

BATH

243A

BEDROOM

CORRIDOR

C22

EXIST.

ELEVATOR

P2-1

CORRIDOR

C23

STAFF

LOUNGE

S U

I T

E

P A

S S

A G

E

C

EXIST.

STAIR

S1-2

N O

R T

H

K

I T

C H

E N

ELECTRICAL

BEDROOM

BEDROOM

EXIST.

STAIR

S4-2

NW

PARLOR/DEN

CEN. MEDICAL

SUPPLY

BEDROOM

BEDROOM

S O

I L

E D

U

T L

H O

L D

I N

G

BEDROOM

CORRIDOR

C32

BEDROOM

BATH

208A

CLEAN UTL.

BATH

236A

MULTI-PURPOSE

ROOM

OFFICE

EQUIPMENT

STORAGE

SHOWER RM

TOILET

OFFICE

STAFF

TOILET

234A

OFFICE

SUITE

PASSAGE

C35

BEDROOM-

BARIATRIC

BEDROOM

SE

PARLOR/DEN

ELECTRICAL

BEDROOM

MEDS/MED

SELECT

SW

PARLOR/DEN

CLOSET

BEDROOM

SOUTH KITCHEN

SOUTH

DINING

LIVING

ROOM

CHARTING

CLEAN

LINEN

HAC

CLOSET

CLEAN

LINEN

CHARTING

SUITE

PASSAGE

C27

LIVING

ROOM

SUITE

PASSAGE

C29

BEDROOM-

BARIATRIC

SUITE

PASSAGE

C38

C O

N F

E R

E N

C E

R O

O M

CORRIDOR

C33

CORRIDOR

C37

BATH

215A

LAUNDRY

HAC

BATH

252A

BATH

220A

ELEV.

LOBBY

SUITE

PASSAGE

C28

CORRIDOR

C30

HAC

STOR.

C O

R R

I D

O R

C

SUITE

PASSAGE

C36

SUITE

PASSAGE

C34

STORAGE

CLOSET

CLOSET

203A

BATH

257A

C23

203A

S

S

150°

C22

C32

C37

4'-10 1/4" 5'-1 1/4"

9 1/4"

8'-0"

HOLD

H O

L D

8'-0"

HOLD

ALIGN

ALIGN

ALIGN

ALIGN WALL

WITH WINDOW

ALIGN WALL

WITH WINDOW

9'-7"

ALIGN WALL

WITH SHAFT

A L

I G

N

W

A L

L

W I T

H

S

H A

F T

7'-4 1/2"

S2-4

BATH

227A

9'-11 1/2"

ALIGN WALL

WITH WINDOW

EXISTING

SHAFT

EXISTING

SHAFT

EXISTING

SHAFT

EXISTING

SHAFT

EXISTING

SHAFT

EXIST

SHAFT

EXISTING

SHAFT

EXISTING

SHAFT

EXISTING

SHAFT

EXISTING

SHAFT

EXISTING

SHAFT

EXISTING

SHAFT

EXISTING

SHAFT

H O

L D

H

O

L

D

SERVICE SINK

ALIGN WALL WITH

EXISTING SHAFT

10'-0 3/4" 6'-0"

ALIGN WALL WITH

EXISTING SHAFT

SERVICE SINK

CLOSET

CLOSET

CLOSET

CLOSET

CLOSET

CLOSET

CLOSET

C L

O S

E T

C L

O S

E T

CLOSET

CLOSET

CLOSET

CLOSET

CLOSET

C L

O S

E T

BEVERAGE

STATION

BEVERAGE

STATION

EXISTING PIPING TO REMAIN.

ENCLOSE WITH TYPE 'C5'

PARTITIONS AS REQUIRED. VERIFY

EXISTING CONDITIONS IN FIELD.

10'-6 3/4"

EXISTING PIPING TO REMAIN.

ENCLOSE WITH TYPE 'C5' PARTITIONS

AS REQUIRED. VERIFY EXISTING

CONDITIONS IN FIELD.

CG1

CG1

CG1

CG1

CG1

CG1

CG1 CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1 CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

WP1

WP1

WP1

WP1

WP1WP1

WP1

CORRIDOR

C26

WP1

WP1

WP1

WP1

CG1

WP2

WP2

WP2

WP1

WP2

WP2

WP3

WP3

WP2

WP2

WP2

WP2

WP3

WP3

WP3

WP3

WP3

WP3

WP3

WP3

WP3

WP3

WP2

WP2

WP3

W P

W P

WP2

OPEN WALL

OPEN WALL

CG1 CG1

CG1

ALIGN

1" INSULATED

GLAZING AT

UPPER SASH

FULLY SPRINKLERED

DESIGN DEVELOPMENT - NOT FOR CONSTRUCTION

SSOE, Inc.

Project #

Troy, MI 48084

Suite 260

T 248-643-6222

1050 Wilshire Drive

015-02007-00

FULLY SPRINKLERED

SCHEMATIC SUBMISSION - NOT FOR CONSTRUCTION

100% BID DOCUMENT SUBMISSION

COMPLETION ITEM NO.

95% CONSTRUCTION DOCUMENTS

DESIGN DEVELOPMENT - NOT FOR CONSTRUCTION

SCHEMATIC DESIGN_REV, MOD P00001 SUBMISSION

95% CONSTRUCTION DOCUMENTS SUBMISSION

NOT FOR CONSTRUCTION

NORTH

GENERAL CONSTRUCTION NOTES

1. DO NOT SCALE DRAWINGS. WORK FROM DIMENSIONS SHOWN. IF ADDITIONAL INFORMATION

IS NEEDED, OR WHERE DRAWINGS OR DRAWING SCALE APPEAR TO CONFLICT WITH

INDICATED DIMENSIONS, BRING TO THE ATTENTION OF THE ARCHITECT FOR REVIEW.

2. COORDINATE SCHEDULE OF OVERALL CONSTRUCTION AND DAY-TO-DAY CONSTRUCTION

OPERATIONS WITH OWNER'S SCHEDULE REQUIREMENTS.

3. FLOOR PLAN DRAWINGS ARE COMPOSITES OF EXISTING CONSTRUCTION TO REMAIN AND

NEW CONSTRUCTION. EXISTING CONSTRUCTION IS SHOWN IN LIGHTER, OUTLINE FORM.

NEW CONSTRUCTION IS INDICATED WITH HEAVIER LINEWORK AND MAY ADDITIONALLY BE

IDENTIFIED BY NOTE, KEYNOTE, LARGER SCALE DETAIL REFERENCE, OR MATERIAL PATTERN

(REFER ALSO TO LEGEND).

4. ALL WALL DIMENSIONS ARE TO FINISH FACE OF WALL UNLESS NOTED OTHERWISE

5. DOCUMENTS ARE BASED ON VA'S RECORD DRAWINGS AND LIMITED FIELD SURVEY. FIELD

VERIFY ALL PROJECT CONDITIONS PRIOR TO THE START OF, AND AS NEEDED DURING THE

COURSE OF, NEW CONSTRUCTION WORK. BRING ANY DISCREPANCIES WHICH MAY

SIGNIFICANTLY AFFECT NEW CONSTRUCTION WORK TO THE ATTENTION OF THE ARCHITECT

FOR REVIEW.

6. KEEP MEANS OF EGRESS OPEN, PROPERLY ILLUMINATED, AND FREE OF OBSTRUCTIONS AT

ALL TIMES.

7. WHERE NEW WALL CONSTRUCTION ABUTS EXISTING, IN-LINE, ON PLANS, DIRECTLY ALIGN

NEW FINISH WALL SURFACE(S) WITH EXISTING.

8. ALL WOOD BLOCKING AND BACKING SHALL BE FIRE-RETARDANT TREATED, UNLESS NOTED

OTHERWISE.

9. KEEP CONSTRUCTION NOISE TO A MINIMUM.

10. NO SMOKING IS ALLOWED INSIDE THE EXISTING BUILDING, INCLUDING AT THE

CONSTRUCTION AREA.

11. PATCH AND REPAIR DENTS, CRACKS, HOLES, AND/OR OTHER UNEVEN SURFACE CONDITIONS

IN EXISTING CONSTRUCTION TO REMAIN.

12. VERIFY THE DIMENSIONS, LOCATIONS, ELEVATIONS AND ARRANGEMENT OF ALL ITEMS

ASSOCIATED WITH INSTALLATION OF EQUIPMENT AND RELATED MECHANICAL AND

ELECTRICAL WORK.

13. NOTIFY THE OWNER AND ARCHITECT OF ANY CODE AND/OR CONSTRUCTION DEFICIENCIES

DISCOVERED OR UNCOVERED IN THE COURSE OF CONSTRUCTION OPERATIONS.

14. THE EXISTING BUILDING, AND ITS SUBSEQUENT CONSTRUCTION MODIFICATIONS, ARE

ASSUMED TO BE IN FULL COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS IN

EFFECT AT THE TIME OF CONSTRUCTION.

15. PATCH EXISTING FLOOR OPENINGS AFTER DEMO OF EXISTING MECHANICAL AND PLUMBING

SHAFTS. REFER TO DETAIL F1/AE503.

16. ALL WALLS SHALL EXTEND TO DECK ABOVE, UNLESS NOTED OTHERWISE. REFER TO TYPICAL

WALL TYPES.

17. WHERE EXISTING WALLS ARE INDICATED AS RATED WALLS, SEAL ALL PENETRATIONS AND

OPENINGS WITH FIRE STOPPING TO MAINTAIN INDICATED RATING. FIELD VERIFY.

18.EXISTING FLOOR IS FIRE RATED. SEAL ALL PENETRATIONS AND OPENINGS WITH FIRE

STOPPING TO MAINTAIN INDICATED RATING.

19.PROVIDE TEMPORARY DUST PARTITIONS AT FIRST AND SECOND FLOOR AND OTHER

OCCUPIED AREAS AS REQUIRED BY CONSTRUCTION WORK. REFER TO TYPICAL DETAILS ON

DRAWING.

20.PROVIDE BLOCKING/METAL SUPPORT STRAPS IN PARTITIONS FOR EQUIPMENT INSTALLATION

(I.E. GRAB BARS, TV MONITORS ETC.) REFER TO DRAWINGS FOR LOCATIONS.

21.VERIFY AND COORDINATE CLEAR CHASE SPACE REQUIREMENTS WITH WALL LOCATIONS FOR

WATER CLOSET AT EACH TOILET AND MECHANICAL AND ELECTRICAL. DUCTS, CONDUITS AND

PIPING WITH EXISTING STRUCTURE AND EXISTING UTILITIES BELOW. CHASE WALL

LOCATIONS SHALL BE ADJUSTED AS REQUIRED TO ALLOW FOR PROPER INSTALLATION

THROUGH EXISTING STRUCTURAL CONCRETE FLOOR SLAB. NOTIFY ARCHITECT PRIOR TO

PROCEEDING. EXISTING UTILITIES BELOW MAY HAVE TO BE REWORKED FOR NEW

CONSTRUCTION.

22. PROVIDE CEMENT BOARD AT ALL SHOWERS AND WET WALLS, TYPICAL.

23. EXISTING CLAY TILE AND PLASTER COLUMN AND STEAM PIPING ENCLOSURE TO REMAIN AT

EXTERIOR WALL COLUMNS. VERIFY EACH LOCATION. REPORT ANY DISCREPANCY TO

ARCHITECT.

24. REFER TO SHEET AE431, AE501 FOR TYPICAL BUILT-UP BATHROOM FLOOR INFORMATION.

25. REFER TO SHEET IN102 FOR TYPICAL WALL TILE LAYOUT DESIGN IN RESIDENT BATHROOMS.

PARTITION TYPE - PARTITION IS

TYPE "A" UNLESS OTHERWISE

NOTED. REFER TO SHEET GI100

FOR DETAILS

XX

2264A

DOOR NUMBER

ROOM NAME

XXX

ROOM TAG

AE4XX

INTERIOR ELEVATION.

REFER TO AE421, AE422,

AE423 AND AE424 FOR

ELEVATIONS

CORNER GUARD- REFER TO

AE502 FOR DETAILS

END GUARD- REFER TO AE502

FOR DETAILS

CG1

EG

FIRE EXTINGUISHER CABINET

REFER TO SPECIFICATIONS

FEC

EXISTING WALL

NEW WALLS

F1

AE421

C1

AE421

G6

AE421

F1

AE423

C1

AE422

B5

AE422

E3 AE424

F3AE424

E6

E5

AE424

E7

AE424

B7

B6B5 AE424

D6

D7

D3

AE424

A7

A6A5 AE424

B6

AE423

F5 AE424

F7

AE424

F6AE424

C2

AE422

A1

FLOOR PLAN LEGEND

OVERALL SECOND FLOOR PLAN

1/8" = 1'-0"AE121

F4

6'-3 1/4"

PATIENT BED CENTERLINE

D8

AE503

3 5/8" METAL STUDS AT 16" ON CENTER WITH ONE (1) LAYER OF 5/8" TYPE 'X' GYPSUM

BOARD ON EACH SIDE. EXTEND STUDS AND GYPSUM BOARD UP TO DECK ABOVE

(UNLESS NOTED OTHERWISE). PROVIDE 3 1/2" SOUND ATTENUATION BLANKETS BETWEEN

STUDS FULL HEIGHT.

3 5/8" METAL STUDS AT 16" ON CENTER WITH ONE (1) LAYER OF 5/8" TYPE 'X' GYPSUM

BOARD ON EACH SIDE. EXTEND STUDS AND GYPSUM BOARD UP TO DECK ABOVE.

PROVIDE 3 1/2" SOUND ATTENUATION BLANKETS BETWEEN STUDS FULL HEIGHT. WALL

TO BE FIRE RATED 1-HOUR (UL #U465)

TWO (2) ROWS 3 5/8" METAL STUDS AT 24" ON CENTER WITH ONE (1) LAYER OF 5/8" TYPE

'X' GYPSUM BOARD ON EACH SIDE. EXTEND STUDS AND GYPSUM BOARD UP TO DECK

ABOVE. PROVIDE 3 1/2" SOUND ATTENUATION BLANKETS BETWEEN STUDS FULL HEIGHT.

PARTITION SHALL BE 10" TOTAL THICKNESS. UNLESS NOTED OTHERWISE.

SOUND RATED SOUND TRANSMISSION CLASS 55.

5 1/2" METAL STUDS AT 16" ON CENTER WITH ONE (1) LAYER OF 5/8" TYPE 'X' GYPSUM

BOARD ON EACH SIDE. EXTEND STUDS AND GYPSUM BOARD UP TO DECK ABOVE

(UNLESS NOTED OTHERWISE). PROVIDE 3 1/2" SOUND ATTENUATION BLANKETS BETWEEN

STUDS FULL HEIGHT.

8" METAL STUDS AT 16" ON CENTER WITH ONE (1) LAYER OF 5/8" TYPE 'X' GYPSUM BOARD

ON EACH SIDE. EXTEND STUDS AND GYPSUM BOARD UP TO DECK ABOVE (UNLESS

NOTED OTHERWISE). PROVIDE 3 1/2" SOUND ATTENUATION BLANKETS BETWEEN STUDS

FULL HEIGHT.

3 5/8" METAL STUDS AT 16" ON CENTER WITH TWO (2) LAYERS OF 5/8" TYPE 'X' GYPSUM

BOARD ON EACH SIDE. EXTEND STUDS AND GYPSUM BOARD UP TO DECK ABOVE

(UNLESS NOTED OTHERWISE). PROVIDE 3 1/2" SOUND ATTENUATION BLANKETS BETWEEN

STUDS FULL HEIGHT. WALL TO BE FIRE RATED 2-HOURS (UL #U411)

EXTERIOR FURRED OUT WALL - 20 GAUGE, 3 5/8" METAL STUDS AT 16" ON CENTER WITH

ONE (1) LAYER 5/8" TYPE 'X' GYPSUM BOARD ON ONE SIDE ONLY AND VAPOR RETARDER.

HOLD STUDS 1" FROM EXTERIOR WALL SURFACE. EXTEND STUDS AND GYPSUM BOARD

TO DECK ABOVE. INFILL STUD SPACE WITH MINERAL WOOL INSULATION, FULL HEIGHT.

EXTERIOR FURRED OUT WALL - 20 GAUGE, 2 1/2" METAL STUDS AT 16" ON CENTER WITH

ONE (1) LAYER 5/8" TYPE 'X' GYPSUM BOARD ON ONE SIDE ONLY AND VAPOR RETARDER.

HOLD STUDS 1" FROM EXTERIOR WALL SURFACE. EXTEND STUDS AND GYPSUM BOARD

TO DECK ABOVE. INFILL STUD SPACE WITH MINERAL WOOL INSULATION, FULL HEIGHT.

EXTERIOR FURRED OUT WALL - 20 GAUGE, 5 1/2" METAL STUDS AT 16" ON CENTER WITH

ONE (1) LAYER 5/8" TYPE 'X' GYPSUM BOARD ON ONE SIDE ONLY AND VAPOR RETARDER.

HOLD STUDS 1" FROM EXTERIOR WALL SURFACE. EXTEND STUDS AND GYPSUM BOARD

TO DECK ABOVE. INFILL STUD SPACE WITH MINERAL WOOL INSULATION, FULL HEIGHT.

2 1/2" METAL STUDS AT 16" ON CENTER WITH ONE (1) LAYER OF TYPE 'X' GYPSUM BOARD

ON ONE SIDE ONLY. 3 1/2" SOUND ATTENUATION BLANKETS BETWEEN STUDS TO TOP OF

GYPSUM BOARD. EXTEND STUDS AND GYPSUM BOARD TO DECK ABOVE.

ONE (1) LAYER OF TYPE 'X' GYPSUM BOARD ON 7/8" METAL FURRING (ONE SIDE ONLY)

OVER EXISTING CONSTRUCTION . EXTEND GYPSUM BOARD AND FURRING TO 6" ABOVE

CEILING.

ONE (1) LAYER OF TYPE 'X' GYPSUM BOARD ON 3 5/8" METAL STUDS AT 16" ON CENTER

(ONE SIDE ONLY). EXTEND GYPSUM BOARD AND STUDS TO DECK ABOVE.

WALL TYPES

A2

A3

B1

C3

C4

S1

S2

S1

S1

S1

C5

S1

S1

S1

S1

S1

S1

S1

S1

S1

C3

C3

C3 C3

C3

C3C3

C3

C3

C3

C3

C3

C3

C3

C3

C3

A3

A2

A2

A2

A2

A2

A2

A2

A2

S2

S2

A

C3

B3, D3

AE501

C

L

FD

FLOOR DRAIN

SEE GI-100 FOR PARTITION TYPE

LEGEND

S1

C5

C5

F1

AE431

F3

AE431

E5

AE431

B2

AE422

F5

AE431

F7

AE431

C2

AE431

B2

AE431

C4

AE431

C6

AE431

WALL PROTECTION. REFER TO

DETAIL B9/AE502

WP1

WALL PROTECTION. REFER TO

DETAIL C9/AE502

WP2

WALL PROTECTION. REFER TO

DETAIL B8/AE502

WP3

A4

C2

A3 AE424

C5

C5

B3AE424

B1

AE502

SHADED AREA INDICATED REINFORCED

CONCRETE SLAB BY GLUED CARBON

FIBER STRIPS TO BOTTOM OF SLABS.

SEE DETAIL ON THIS SHEET FOR MORE

INFORMATION.

A3

AE502

F1

AE501

B1

AE424

A5

SLAB S29

EXISTING SLAB FLEXURAL CAPACITY = 27.1 K-IN

REQUIRED SLAB FLEXURAL CAPACITY = 31.2 K-IN

SLAB S30

EXISTING SLAB FLEXURAL

CAPACITY = 13.9 K-IN

REQUIRED SLAB FLEXURAL

CAPACITY = 19.0 K-IN

SHADED AREA INDICATED REINFORCED

CONCRETE SLAB BY GLUED CARBON

FIBER STRIPS TO BOTTOM OF SLABS.

SEE DETAIL ON THIS SHEET FOR MORE

INFORMATION..

SLAB S29

EXISTING SLAB FLEXURAL

CAPACITY = 27.1 K-IN

REQUIRED SLAB FLEXURAL

CAPACITY = 31.2 K-IN

SLAB S30

EXISTING SLAB FLEXURAL

CAPACITY = 13.9 K-IN

REQUIRED SLAB FLEXURAL

CAPACITY = 19.0 K-IN

C

L

C

L

C

L

C

L

C

L

C

L

C

L

C

L

C

L

C

L

C

L

C

L

C

L

C

L

C

L

FD

R a c a c a ba bac a

R

R

R

EXP

EXP

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

7'-6"

7'-0"

3'-10" 4'-3"

2'-4"

7'-1 3/4"

4'-7"

2'-9"

7'-6"

7'-0"

NORTH

DINING

BEDROOM-

BARIATRIC

CHARTING

EXIST.

STAIR

S2-2

BATH

256A

BATH

245A

EXIST.

STAIR

S3-2

BEDROOM

NE

PARLOR/DEN

BATH

221A

BEDROOM

BATH

214A

BATH

210A

BATH

253A

SUITE

PASSAGE

C25

UNIT

COORDINATOR

LOCKER

ROOM

BATH

254A

CHARTING

BATH

243A

BEDROOM

CORRIDOR

C22

EXIST.

ELEVATOR

P2-1

CORRIDOR

C23

STAFF

LOUNGE

SUITE

PASSAGE

C31

EXIST.

STAIR

S1-2

NORTH KITCHEN

ELECTRICAL

BATH

227A

BEDROOM

BEDROOM

EXIST.

STAIR

S4-2

NW

PARLOR/DEN

CEN. MEDICAL

SUPPLY

BEDROOM

BEDROOM

SOILED UTL/

HOLDING

BEDROOM

CORRIDOR

C32

BEDROOM

BATH

208A

CLEAN UTL.

BATH

236A

MULTI-PURPOSE

ROOM

OFFICE

EQUIPMENT

STORAGE

SHOWER RM

TOILET

OFFICE

STAFF

TOILET

234A

OFFICE

SUITE

PASSAGE

C35

BEDROOM-

BARIATRIC

BEDROOM

SE

PARLOR/DEN

ELECTRICAL

BEDROOM

MEDS/MED

SELECT

SW

PARLOR/DEN

BEDROOM

SOUTH KITCHEN

SOUTH

DINING

LIVING

ROOM

CHARTING

CLEAN

LINEN

HAC

CLOSET

CLEAN

LINEN

CHARTING

SUITE

PASSAGE

C27

LIVING

ROOM

SUITE

PASSAGE

C29

BEDROOM-

BARIATRIC

SUITE

PASSAGE

C38

CONFERENCE

ROOM

CORRIDOR

C33

CORRIDOR

C37

BATH

215A

LAUNDRY

HAC

BATH

252A

BATH

220A

ELEV.

LOBBY

CORRIDOR

C26

CORRIDOR

C28

CORRIDOR

C30

HAC STOR.

CORRIDOR

C24

CORRIDOR

C36

SUITE

PASSAGE

C34

STORAGE

CLOSET

CLOSET

203A

BATH

257A

CLOSET

1'-10"

5'-1"

1'-0"

4'-0"

2'-9"

3'-0"

7'-6"

2'-9"

E Q

E Q

R

R

R

7'-0"

E Q

E

Q

2'-6"

5'-1"

4'-0"

EQ

EQ

2'-9"

3'-1"

3'-0"

6'-0" 2'-8"

2'-0"

7'-0"

MEDS/MED

SELECT

ALIGN

ALIGN

E Q

E Q

2'-0

5'-0"

R

T Y

P I C

A L

SOFFIT HEIGHT

REFER TO CEILING PLAN

VARIES REFER TO REFLECTED CEILING PLAN

CEILING SYSTEM

5/8" GYPSUM

BOARD ON METAL

STUD FRAMING AT

16" ON CENTER.

CEILING HEIGHT

REFER TO CEILING PLAN

3 5/8" METAL STUD,

DIAGONAL BRACE AT

4'-0" ON CENTER

T Y

P I C

A L

CEILING HEIGHT

REFER TO CEILING PLAN

SOFFIT HEIGHT

REFER TO CEILING PLAN

REFER TO

REFLECTED CEILING PLAN

3 5/8" METAL STUD,

DIAGONAL BRACE AT

4'-0" ON CENTER

CEILING SYSTEM

5/8" GYPSUM

BOARD ON METAL

STUD FRAMING AT

16" ON CENTER

T Y

P I C

A L

CEILING HEIGHT

REFER TO CEILING PLAN

CEILING SYSTEM

5/8" GYPSUM

BOARD ON METAL

STUD FRAMING AT

16" ON CENTER

3 5/8" METAL STUD

DIAGONAL BRACE

AT 4'-0" ON CENTER

12" 12"

M B

E D

EXISTING

FLOOR SLAB

WT5X16.5 ORIENTED

PERPENDICULAR TO

DIRECTION OF SLAB

SPAN

LIFT HANGER, BY

LIFT

MANUFACTURER

1/2" DIAMETER HILTI

KWIK HUS-EZ

SCREW ANCHORS

NS/FS IN WT

FLANGE (4

ANCHORS TOTAL).

EMBED 2 1/4"

DO NOT ATTACH

TO BOTTOM OF

EXISTING JOIST,

TYPICAL

ATTACH TO THE SIDE

OF CONCRETE PAN

JOIST AS SHOWN

SUPPORT SYSTEM,

AS REQUIRED, BY

LIFT MANUFACTURER

CEILING

SYSTEM

PATIENT LIFT

TRACK, BY LIFT

MANUFACTURER

(2) 3/4" DIAMETER

HILTI KWIK BOLT

3 EXP ANCHORS

NS/FS IN WT

FLANGE.

MINIMUM EMBED

= 3 1/2"

WT5X16.5

EXISTING WALL

AND WINDOW

ALIGN BULKHEAD

WITH WINDOW

MATCH NEW SOFFIT

HEIGHT WITH EXISTING

WINDOW HEAD

CEILING HEIGHT 7'-10"

ABOVE FINISH FLOOR

CEILING HEIGHT 8'-0"

ABOVE FINISH FLOOR

5"

9"

ALIGN BULKHEAD

WITH WINDOW

MATCH NEW SOFFIT

HEIGHT WITH

EXISTING WINDOW

HEAD

EXISTING WALL

AND WINDOW

CEILING HEIGHT 7'-10"

ABOVE FINISH FLOOR

CEILING HEIGHT 8'-0"

ABOVE FINISH FLOOR

CEILING HEIGHT 7'-6"

ABOVE FINISH FLOOR

SSOE, Inc.

Project #

Troy, MI 48084

Suite 260

T 248-643-6222

1050 Wilshire Drive

015-02007-00

FULLY SPRINKLERED

SCHEMATIC SUBMISSION - NOT FOR CONSTRUCTION

100% BID DOCUMENT SUBMISSION

COMPLETION ITEM NO.

95% CONSTRUCTION DOCUMENTS

DESIGN DEVELOPMENT - NOT FOR CONSTRUCTION

SCHEMATIC DESIGN_REV, MOD P00001 SUBMISSION

95% CONSTRUCTION DOCUMENTS SUBMISSION

NOT FOR CONSTRUCTION

SECOND FLOOR REFLECTED CEILING PLAN

1/8" = 1'-0"AE121

F3

RECESSED DOWNLIGHT

REFER TO ELECTRICAL

2' X 4' LIGHT FIXTURE

REFER TO ELECTRICAL

2X2 ACOUSTIC CEILING TILE GRID

(SEE ROOM FINISH SCHEDULE)

PAINTED GYPSUM BOARD CEILING

CEILING HEIGHT

EXPOSED TO STRUCTURE ABOVE

2' X 2' LIGHT FIXTURE

REFER TO ELECTRICAL

LIFT TRACK

NOTES

REFLECTED CEILING PLAN NOTES

1. CONTRACTOR SHALL ADJUST CEILING GRIDS TO

CENTER THEM IN ROOMS AND CREATE EQUAL TILE

SPACING AT ENDS OF ROOMS.

2. ALL TECHNOLOGY EQUIPMENT LOCATIONS ARE

DIAGRAMMATIC. REFER TO THE TECHNOLOGY

DRAWINGS. COORDINATE FINAL LOCATION OF

CEILING MOUNTED EQUIPMENT WITH ALL TRADES.

3. ALL LIGHT FIXTURE, MECHANICAL DIFFUSER

LOCATIONS AND TECHNOLOGY ITEMS ARE

DIAGRAMMATIC IN NATURE AND SOME ITEMS MAY

NOT BE SHOWN FOR CLARITY. REFER TO THE

MECHANICAL AND ELECTRICAL DRAWINGS FOR ALL

ITEMS TO BE PROVIDED. COORDINATE FINAL

LOCATION OF CEILING MOUNTED EQUIPMENT WITH

ALL TRADES.

4. ALL CEILING TO BE 8'-0" (UNLESS NOTED

OTHERWISE).

5. LIGHTS ARE TO BE CENTERED IN BATHROOM AND

SHOWERS (UNLESS NOTED OTHERWISE).

LEGEND

RATED WALL LEGEND

2 HOUR FIRE BARRIER

(EXISTING)

1 HOUR FIRE BARRIER (NEW)

SMOKE BARRIER (NEW)

WIDE SOFFIT DETAIL

1 1/2" = 1'-0"AE221

F1

SOFFIT AT WALL DETAIL

1 1/2" = 1'-0"AE221

E1

E1

AE221

D1

AE221

TYPICAL

F1

AE221

C1

AE221

1X4 LIGHT FIXTURE

REFER TO ELECTRICAL

7'-6"

EXP

CEILING TRANSITION DETAIL

1 1/2" = 1'-0"AE221

C1

TYPICAL PATIENT LIFT BRACKET AT CONCRETE SLAB

1 1/2" = 1'-0"AE221

B1

TYPICAL PATIENT LIFT SUPPORT

1 1/2" = 1'-0"AE221

A1

V E

R I F

Y

KEYNOTES

REFER TO DETAIL B1/AE501 FOR SOFFIT DETAIL.

REFER TO DETAIL B4/AE501 FOR SOFFIT DETAIL.

REFER TO DETAIL C1/AE221 FOR CEILING

TRANSITION DETAIL.

F4

AE221

TYPICAL

11111

1 1

1 1

1 1

1 2

TYPICAL

PLAN DETAIL AT WINDOW SOFFIT

1 1/2" = 1'-0"AE221

F4 PLAN DETAIL AT WINDOW SOFFIT

1 1/2" = 1'-0"AE221

F6

F6

AE221

B1

AE501

B1

AE501

B4

AE501

PRIVACY CURTAIN TRACK

AIR SUPPLY GRILLE.

REFER TO MECHANICAL

AIR RETURN GRILLE.

REFER TO MECHANICAL

CEILING MOUNTED SPEAKER

REFER TO TELECOMMUNICATIONS

Y

P

PENDANT LIGHT FIXTURE

F1

AE221

E1

AE221

TYPICAL

http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com

220A

C

C

A

F E

C

C

L

C

L

6'-7"

5'-0"

BEDROOM

NE

PARLOR/DEN

BATH

221A

BEDROOM

CLOSET

SUITE

PASSAGE

C29

BATH

220A

2'-8"

LAV

LAV

WC

WC

C3

C3

C2

C4S1

C5

C3

C3

C3

A3

A3

11'-7"

6'-1 1/2"

5'-1" 4'-4 3/4" 7'-4"

A01

A14

E X

I S

T I N

G

S H

A F

T

SHELF AND

ROD REFER

TO B8/AE501

A01

A14

A06

ADA MARBLE

THRESHOLD

(TYPICAL)

REFER TO

DETAIL

F7/AE501

SHOWER

SHOWER

A06

SAFETY GLAZING SECURITY FILM -

INSTALL ON INSIDE FACE OF

EXISTING GLAZING

TV

CLOSET

CLOSET

TV

PROVIDE PRIVACY

WINDOW FILM ON

BATHROOM

WINDOWS

(TYPICAL)

PROVIDE

PRIVACY

WINDOW FILM

ON BATHROOM

WINDOWS

(TYPICAL)

A18

A18

CG1

CG1

EG

CG1

CG1

CG1

WP1

WP1

WP1

C3C3

C2

C3

C3

C3

C3

FD

FD

FEC

FD

WP3

WP3

WP3

WP3

Ø

C

210A

S2-4

C

L

ALIGN

2'-2" 5'-0" 3'-3" 5'-8" 4'-10"

BEDROOM-

BARIATRIC

BATH

210A

CHARTING

CLEAN

LINEN

SUITE

PASSAGE

C27

CORRIDOR

C26

LAV

WC

1'-0"

4'-6"

C4

C4

C4

S1

S1

C3

C3

A2

10'-0"

CLOSET

SHOWER

A06

A14

A1

EXISTING

SHAFT

WALL MOUNTED

CHARTING STATION.

PROVIDE BLOCKING

AS REQUIRED

SAFETY GLAZING SECURITY FILM -

INSTALL ON INSIDE FACE OF

EXISTING GLAZING

PROVIDE PRIVACY FILM ON ALL

BATHROOM WINDOWS (TYPICAL)

A18

CG1

CG1

CG1

C3

FD

FD

CG1

CG1

WP3

A10

A05

A14

A08

A02

A21

A20

3'-0" 2'-0"

3'-0"

SHOWER WIDTH

6"

A06

A09

A03

A10

A18

EQUAL EQUAL

A12

A10

A07

A05

A11

A09

A06

3'-0"

SHOWER WIDTH

6"

A18

A01

EXISTING WINDOW

PRIVACY WINDOW

FILM AND SAFETY

GLAZING SECURITY

FILM

CEILING POCKET BEYOND

REFER TO DETAIL B1/AE501

PLASTIC LAMINATE

SIDE PANEL

A21

A14

A08

A02

A21

A13

A06

EXISTING

WINDOW

3'-0" 2'-0"

PRIVACY WINDOW

FILM AND SAFETY

GLAZING

A01

A19

(CENTER

ON WALL)

EXISTING

WINDOW

PRIVACY WINDOW

FILM AND SAFETY

GLAZING

A21

PLASTIC LAMINATE

A05

A10

A12

PRIVACY WINDOW

3'-0"

SHOWER WIDTH

6"

A09

A06

A03

A10

A18

EQUAL EQUAL

A14

A08

A02

A06

A09

A21

A07

A05

A10

3'-0" 2'-0"

A18

A11

A03

A09

A06

A10

A18

EQUALEQUAL

A11

A05

A19

(CENTER ON

WALL)

PRIVACY

WINDOW

FILM

EXISTING

WINDOW

3'-0"

SHOWER WIDTH

6"

A01

(CENTER ON

A12

A21

PLASTIC

LAMINATE

SIDE PANEL

W

D

A

C

C

A

F

E

C

C

L

C

L

8'-1 1/4"

2'-7"

5'-0"

9'-7"2'-7"5'-0"

4'-5"4'-5"

5'-9"

5'-9"

BATH

214A

SUITE

PASSAGE

C25

BEDROOM

BEDROOM

BATH

215A

CORRIDOR

C24

LAV

LAV

WC

WC

C3

C3

C3

C3

A3

A3

A3 S1

A01

A14

A14

A01

SHOWER

SHOWER

A06

A06

ALIGN WALL WITH

EXISTING WINDOW

CLOSET

CLOSET

TV

TV

8'-0"

A18

A18

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

WP1

WP1

WP1

FD

WP1

ADA

THRESHOLD

(TYPICAL)

REFER TO

DETAIL F7/AE501

FD

FD

FEC

S2

W/

INSULATION

A3

ADA

THRESHOLD

(TYPICAL)

REFER TO

DETAIL F7/AE501

C3

BELOW

WINDOW

WP3

WP3

WP3

WP3

WP3

WP3

WP3

Ø

Ø6'-4" TYP.

T

Y

P

A07

A05

A11

A10

A20

6"

3'-0"

SHOWER WIDTH

A01

A12

2'-9"

PLASTIC

LAMINATE

SIDE PANEL

A05

A10

A14

A08

A02

A15

A06

A09

A21

3'-0" 2'-0"

A18

A03

A09

A06

A10

A18

EQUAL EQUAL

A20

A10

A11

A07

A05

3'-0"

SHOWER WIDTH

6"

3'-0"

SHOWER WIDTH

A09

A03

A06

A10

A18

EQUALEQUAL

A14

A08

A02

A09

A06

A21

2'-0" 3'-0"

A18

A01

A12

2'-0"

A21

PLASTIC LAMINATE

SIDE PANEL

4'-6"

BASE

REFER TO FINISH

SCHEDULE

CHARTING

STATION

CORNER

GUARD

4'-6"

BASE

REFER TO

FINISH

SCHEDULE

SSOE, Inc.

Project #

Troy, MI 48084

Suite 260

T 248-643-6222

1050 Wilshire Drive

015-02007-00

SCHEMATIC SUBMISSION - NOT FOR CONSTRUCTION

100% BID DOCUMENT SUBMISSION

95% CONSTRUCTION DOCUMENTS

DESIGN DEVELOPMENT - NOT FOR CONSTRUCTION

SCHEMATIC DESIGN_REV, MOD P00001 SUBMISSION

95% CONSTRUCTION DOCUMENTS SUBMISSION

NOT FOR CONSTRUCTION

NORTHNORTH

SECOND FLOOR ENLARGED PLAN

1/4" = 1'-0"AE121

F1

C1AE503

C3 AE503

C1

AE503

D7

C7

D6C6 AE421

D4

C4

D3C3 AE421

F4

E4

F3E3 AE421

BATH 220A

1/4" = 1'-0"AE421

E3

F3

BATH 221A

C3

C4

D3

D4

BATH 215A

A3 BATH 215A

A4

BATH 215A

B3 BATH 215A

B4

BATH 214A

A6 BATH 214A

A7

B6

B7

BATH 210A

1/4" = 1'-0"AE421

D6 BATH 210A

1/4" = 1'-0"AE421

D7

BATH 210A

1/4" = 1'-0"AE421

C6 BATH 210A

1/4" = 1'-0"AE421

C7

SECOND FLOOR ENLARGED PLAN

1/4" = 1'-0"AE121

G6

D8

C8

AE421

B7

A7

B6A6 AE421

B4

A4

B3A3 AE421

C3

AE503

C1

AE503

B1

AE510

B1

AE510

B1

AE510

B1

AE510

B1

AE510

CHARTING 209

C8

D8

B3,D3

AE501

B3,D3

AE501

ABBREVIATIONS:

C/C CONTRACTOR FURNISHED/CONTRACTOR INSTALLED

V/C VA FURNISHED/CONTRACTOR INSTALLED V/V VA FURNISHED/ VA INSTALLED

F8

AE510

B3,D3

AE501

BATHROOM ACCESSORY LEGEND

ID # DESCRIPTION

PROVIDED/

INSTALLED

BLOCKING

REQUIRED

A01

DISPENSER, PAPER TOWEL, STAINLESS STEEL, SURFACE

MOUNTED

V/C YES

A02

DISPENSER, SOAP

V/C NO

A03

42" GRAB BAR, 1 1/4" DIAMETER STAINLESS STEEL, WHEELCHAIR

ACCESSIBLE

C/C YES

A04

36" GRAB BAR, 1 1/4" DIAMETER STAINLESS STEEL, WHEELCHAIR

ACCESSIBLE

C/C YES

A05

24" GRAB BAR, 1 1/4" DIAMETER, WHEELCHAIR ACCESSIBLE

C/C YES

A06

24" UP-SWINGING GRAB BAR, 1 1/4" DIAMETER, STAINLESS

STEEL, WHEELCHAIR ACCESSIBLE

C/C YES

A07

18" VERTICAL GRAB BAR, 1 1/4" DIAMETER STAINLESS STEEL

C/C YES

A08

MIRROR, FLOAT GLASS, WITH WOOD FRAME (18"W X 30" H)

C/C NO

A09 NURSE CALL C/C NO

A10

ROD, SHOWER, WITH CURTAIN

C/C NO

A11

SHOWER, HANDHELD

C/C NO

A12

HOOK, GARMENT, DOUBLE

C/C YES

A13 NOT USED - -

A14 RECESSED CABINET C/C YES

A15 NOT USED

A16 NOT USED - -

A17

MEDICINE CABINET, REFER TO DETAIL F3/AE502 UNLESS NOTED

OTHERWISE.

- YES

A18 TOILET TISSUE DISPENSER C/C YES

A19 24" TOWEL BAR C/C YES

A20 36" TOWEL BAR C/C YES

A21 WALL MOUNTED VANITY FIXTURE C/C NO

NORTH

SECOND FLOOR ENLARGED PLAN

1/4" = 1'-0"AE121

C1

GENERAL CONSTRUCTION NOTES

FLOOR PLAN LEGEND

B8

AE501

TYPICAL

SIMILAR

PARTITION TYPE - PARTITION IS

TYPE "A" UNLESS OTHERWISE

NOTED. REFER TO SHEET GI100

FOR DETAILS

XX

DOOR NUMBER

ROOM NAME

INTERIOR ELEVATION KEY.

REFER TO AE421, AE422,

AE423, AND AE424 FOR

ELEVATIONS

CORNER GUARD- REFER TO

AE502 FOR DETAILS

END GUARD- REFER TO AE502

FOR DETAILS

CG1

EG

FIRE EXTINGUISHER CABINET

REFER TO SPECIFICATIONS

FEC

EXISTING WALL

NEW WALLS

PATIENT BED CENTERLINE

C

L

FD

FLOOR DRAIN

WALL PROTECTION. REFER TO

DETAIL B9/AE502

WP1

WALL PROTECTION. REFER TO

DETAIL C9/AE502

WP2

WALL PROTECTION. REFER TO

DETAIL B8/AE502

WP3

1. DO NOT SCALE DRAWINGS. WORK FROM DIMENSIONS SHOWN. IF ADDITIONAL INFORMATION

IS NEEDED, OR WHERE DRAWINGS OR DRAWING SCALE APPEAR TO CONFLICT WITH

INDICATED DIMENSIONS, BRING TO THE ATTENTION OF THE ARCHITECT FOR REVIEW.

2. COORDINATE SCHEDULE OF OVERALL CONSTRUCTION AND DAY-TO-DAY CONSTRUCTION

OPERATIONS WITH OWNER'S SCHEDULE REQUIREMENTS.

3. FLOOR PLAN DRAWINGS ARE COMPOSITES OF EXISTING CONSTRUCTION TO REMAIN AND

NEW CONSTRUCTION. EXISTING CONSTRUCTION IS SHOWN IN LIGHTER, OUTLINE FORM.

NEW CONSTRUCTION IS INDICATED WITH HEAVIER LINEWORK AND MAY ADDITIONALLY BE

IDENTIFIED BY NOTE, KEYNOTE, LARGER SCALE DETAIL REFERENCE, OR MATERIAL PATTERN

(REFER ALSO TO LEGEND).

4. ALL WALL DIMENSIONS ARE TO FINISH FACE OF WALL UNLESS NOTED OTHERWISE

5. DOCUMENTS ARE BASED ON VA'S RECORD DRAWINGS AND LIMITED FIELD SURVEY. FIELD

VERIFY ALL PROJECT CONDITIONS PRIOR TO THE START OF, AND AS NEEDED DURING THE

COURSE OF, NEW CONSTRUCTION WORK. BRING ANY DISCREPANCIES WHICH MAY

SIGNIFICANTLY AFFECT NEW CONSTRUCTION WORK TO THE ATTENTION OF THE ARCHITECT

FOR REVIEW.

6. KEEP MEANS OF EGRESS OPEN, PROPERLY ILLUMINATED, AND FREE OF OBSTRUCTIONS AT

ALL TIMES.

7. WHERE NEW WALL CONSTRUCTION ABUTS EXISTING, IN-LINE, ON PLANS, DIRECTLY ALIGN

NEW FINISH WALL SURFACE(S) WITH EXISTING.

8. ALL WOOD BLOCKING AND BACKING SHALL BE FIRE-RETARDANT TREATED, UNLESS NOTED

OTHERWISE.

9. KEEP CONSTRUCTION NOISE TO A MINIMUM.

10. NO SMOKING IS ALLOWED INSIDE THE EXISTING BUILDING, INCLUDING AT THE

CONSTRUCTION AREA.

11. PATCH AND REPAIR DENTS, CRACKS, HOLES, AND/OR OTHER UNEVEN SURFACE CONDITIONS

IN EXISTING CONSTRUCTION TO REMAIN.

12. VERIFY THE DIMENSIONS, LOCATIONS, ELEVATIONS AND ARRANGEMENT OF ALL ITEMS

ASSOCIATED WITH INSTALLATION OF EQUIPMENT AND RELATED MECHANICAL AND

ELECTRICAL WORK.

13. NOTIFY THE OWNER AND ARCHITECT OF ANY CODE AND/OR CONSTRUCTION DEFICIENCIES

DISCOVERED OR UNCOVERED IN THE COURSE OF CONSTRUCTION OPERATIONS.

14. THE EXISTING BUILDING, AND ITS SUBSEQUENT CONSTRUCTION MODIFICATIONS, ARE

ASSUMED TO BE IN FULL COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS IN

EFFECT AT THE TIME OF CONSTRUCTION.

15. PATCH EXISTING FLOOR OPENINGS AFTER DEMO OF EXISTING MECHANICAL AND PLUMBING

SHAFTS. REFER TO DETAIL F1/AE503.

16. ALL WALLS SHALL EXTEND TO DECK ABOVE, UNLESS NOTED OTHERWISE. REFER TO TYPICAL

WALL TYPES.

17. WHERE EXISTING WALLS ARE INDICATED AS RATED WALLS, SEAL ALL PENETRATIONS AND

OPENINGS WITH FIRE STOPPING TO MAINTAIN INDICATED RATING. FIELD VERIFY.

18.EXISTING FLOOR IS FIRE RATED. SEAL ALL PENETRATIONS AND OPENINGS WITH FIRE

STOPPING TO MAINTAIN INDICATED RATING.

19.PROVIDE TEMPORARY DUST PARTITIONS AT FIRST AND SECOND FLOOR AND OTHER 1 HR

FIRE RATED SEPARATION REQUIRED OCCUPIED AREAS AS REQUIRED BY CONSTRUCTION

WORK. REFER TO T-1 WALL TYPE.

20.PROVIDE BLOCKING/METAL SUPPORT STRAPS IN PARTITIONS FOR EQUIPMENT INSTALLATION

(I.E. GRAB BARS, TV MONITORS ETC.) REFER TO DRAWINGS FOR LOCATIONS.

21.VERIFY AND COORDINATE CLEAR CHASE SPACE REQUIREMENTS WITH WALL LOCATIONS FOR

WATER CLOSET AT EACH TOILET AND MECHANICAL AND ELECTRICAL. DUCTS, CONDUITS AND

PIPING WITH EXISTING STRUCTURE AND EXISTING UTILITIES BELOW. CHASE WALL

LOCATIONS SHALL BE ADJUSTED AS REQUIRED TO ALLOW FOR PROPER INSTALLATION

THROUGH EXISTING STRUCTURAL CONCRETE FLOOR SLAB. NOTIFY ARCHITECT PRIOR TO

PROCEEDING. EXISTING UTILITIES BELOW MAY HAVE TO BE REWORKED FOR NEW

CONSTRUCTION.

22. PROVIDE CEMENT BOARD AT ALL SHOWERS AND WET WALLS, TYPICAL.

23. EXISTING CLAY TILE AND PLASTER COLUMN AND STEAM PIPING ENCLOSURE TO REMAIN AT

EXTERIOR WALL COLUMNS. VERIFY EACH LOCATION. REPORT ANY DISCREPANCY TO

ARCHITECT.

24. REFER TO SHEET AE431, AE501 FOR TYPICAL BUILT-UP BATHROOM FLOOR INFORMATION.

25. REFER TO SHEET IN102 FOR TYPICAL WALL TILE LAYOUT DESIGN IN RESIDENT BATHROOMS.

A2

AE502

C3

AE502

C1

AE502

C8

F8

AE510

XXX

F8

AE510

REFER TO STD MOUNTING HEIGHTS

ON GI100

http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com

227A

C

C

L

BATH

227A

SOILED UTL/

HOLDING

BEDROOM

8'-5 3/4"5'-1" 5'-0" 2'-2"

ALIGN

ALIGN WALL WITH

EXISTING SHAFT WC

LAV

SHOWER

A01

A14

A

C4

S1

S2 S2

C3 C3

A2

A2

A2

A2

SAFETY GLAZING

SECURITY FILM -

INSTALL ON INSIDE

FACE OF EXISTING

GLAZING

ALIGN

ALIGN WALL WITH

EXISTING STAIRWELL

WALL

CLOSET

TV

CLINICAL

SINK

HAND

SINK

3'-2"

PROVIDE PRIVACY

FILM ON ALL

BATHROOM WINDOWS

(TYPICAL)

A18

CG1

CG1

ADA

THRESHOLD

(TYPICAL)

FD

FD

Ø

STAINLESS

STEEL COUNTER

AND SINK

C3

S1

WP1

CG1

S1

208A

203A

208C

C

L

BEDROOM

BATH

208A

C L

O S

E T

A

10'-0 1/4" 6" 3'-0"

EXISTING

CONDUITS

EXISTING

SHAFT

1'-10"

WC

LAV

SHOWER

A01

A14

A06

S1

S2

S2

C3

A2

SAFETY GLAZING SECURITY FILM - INSTALL

ON INSIDE FACE OF EXISTING GLAZING

ALIGN WALL

WITH EXISTING

SHAFT

C L

O S

E T

TV

A18

CG1

SERVICE SINK

S1

FD

FD

ADA MARBLE

THRESHOLD

(TYPICAL)

C3

4'-0"

WP2

WP3

WP1

WP1

WP3

257A

256C

256A

257C

C22 C32

C

L

C

L

257A

256C

256A

257C

BATH

256A

BEDROOM

BATH

257A

BEDROOM

EQUIPMENT

STORAGE

TOILET

13'-8 1/2" 16'-4 1/2"2'-11 1/4"5'-0"

2'-10"

WC

WC

LAV

LAV

SHOWER

SHOWER

A01

A14

A06

A01

A14

A06

S1

S1

S2

S2

C3

C3

A3

A3

A2

SAFETY GLAZING SECURITY FILM - INSTALL

ON INSIDE FACE OF EXISTING GLAZING

5'-0"

7'-7"

C L O

S E

T

C L

O S

E T

TV

TV

A18

A18

A18

S1

CG1

CG1

WP3

WP1

A18

LAV

FDFD

FD

FEC

ADA THRESHOLD

(TYPICAL)

REFERENCE

DETAIL F7/AE501

FD

FD

STORAGE

C3

WP1

WP1

WP3

WP3

C

A

C

245A

C

L

C

L 245

C

A

C

BATH

245A

SUITE

PASSAGE

C35

BEDROOM-

BARIATRIC

BEDROOM

SE

PARLOR/DEN

HAC

STOR.

SUITE

PASSAGE

C34

3'-0"

13'-3 1/4"

ALIGN

EXISTING

SHAFT

BATH

243A

A01

A14

A01

A14

A06

A06

LAV

LAV

WC

WC

SHOWER

C4

C2

C4

C4

C4

C3

C3

C3

A3

C3

C3

SAFETY GLAZING

SECURITY FILM -

INSTALL ON INSIDE

FACE OF EXISTING

GLAZING

8'-0"

HOLD

3'-11 1/2" 4'-0 1/2" 9'-0 3/4"

5'-4" 7'-0 1/2" 4'-4 1/4"

7'-6 1/4"

1'-0"

SHOWER

5'-7"

C5

CLOSET

CLOSET

TV

PROVIDE PRIVACY FILM

ON ALL BATHROOM

WINDOWS (TYPICAL)

A18

A18

CG1

EG

CG1

CG1

CG1

CG1

CG1

CG1

CG1

FD

FD

C5

FD

FD

TV

ADA THRESHOLD

(TYPICAL) REFERENCE

DETAIL F7/AE501

5'-8"

WP1

WP3

WP3

WP1

WP1

WP3

WP2

FEC

Ø

CG1

CG1

CG1

CG1

Ø

A12

A01

A21

PLASTIC LAMINATE

A11

A05

A20

3'-0"

SHOWER WIDTH

6"

A09

A03

A06

A10

A18

EQUAL EQUAL

A10

A07

A05

A11

A09

A06

A14

A08

A02

A15

A21

A13

3'-0"2'-0"

A18

3'-0" SHOWER WIDTH

6"

A11

A05

A20

A12

3'-0"

SHOWER WIDTH

6"

A01

EXISTING

WINDOW

PRIVACY

WINDOW

FILM

A21

PLASTIC

LAMINATE

SIDE PANEL

A14

A08

A02

A21

A06

A07

A05

A10

A11

A09

3'-0" 2'-0"

3'-0"

SHOWER WIDTH

6"

A18

A03

A06

A09

A10

A18

EQUAL EQUAL

A14

A08

A02

A21

A10

A05

A20

3'-0"

2'-0"

3'-0"

SHOWER WIDTH

6"

A09

A03

A10

A06

A18

EQUAL EQUAL

A10

A11

A07

A05

A12

A09

A06

A18

A01

EXISTING WINDOW WITH NEW

PRIVACY WINDOW FILM

A21

A10

A11

A07

A05

A12

A20

3'-0"

SHOWER WIDTH

6"

A01

A21

A10

A05

A14

A08

A02

A06

A09

A21

4'-0"

2'-0" A18

A06

A03

A09

A10

A18

EQUAL EQUAL

A10

A11

A07

A05

A09

A06

A20

A18

A09

A03

A10

A06

A18

EQUAL EQUAL

A14

A08

A02

A21

A10

A05

3'-0" 2'-0"

EXISTING

WINDOW

PRIVACY

WINDOW

FILM

A01

A12

A21

A15

A16

A12

A01

A21

A10

A11

A07

A05

A09

A06

A14

A08

A02

A21

3'-0"2'-0"

A18

A09

A03

A10

A06

A18

EQUAL EQUAL

A10

A05

A19

EXISTING

WINDOW

PRIVACY

WINDOW FILM

6"

3'-0" SHOWER WIDTH

3'-0"

A08

A02

A21

A08

A02

A21

A01

A12

A21

PLASTIC

LAMINATE SIDE

PANEL

A05

A18

A12

A09

A03

A18

A07

A01

A02

HAND WASH LAVATORY

BASE

REFER TO FINISH

SCHEDULE

CLINICAL

SINK

STAINLESS STEEL

COUNTERTOP WITH

INTEGRAL BACKSPLASH

REFER TO PLUMBING

STAINLESS STEEL

SHELF

SSOE, Inc.

Project #

Troy, MI 48084

Suite 260

T 248-643-6222

1050 Wilshire Drive

015-02007-00

SCHEMATIC SUBMISSION - NOT FOR CONSTRUCTION

100% BID DOCUMENT SUBMISSION

95% CONSTRUCTION DOCUMENTS

DESIGN DEVELOPMENT - NOT FOR CONSTRUCTION

SCHEMATIC DESIGN_REV, MOD P00001 SUBMISSION

95% CONSTRUCTION DOCUMENTS SUBMISSION

NOT FOR CONSTRUCTION

SECOND FLOOR ENLARGED PLAN

1/4" = 1'-0"AE121

C1

NORTH

SECOND FLOOR ENLARGED PLAN

1/4" = 1'-0"AE121

B2

C2

C1 AE503

C1AE503

C3 AE503

C3 AE503

C1

AE503

AE503

BATHROOM 208A

1/4" = 1'-0"AE422

D5

D6

E5

E6

BATHROOM 227A

B5

C5

C6

BATHROOM 257A

D7

BATHROOM 257A

D8

E7

E8

BATHROOM 256A

B7

B8

C7

C8

B5

E2

D2

E1D1 AE422

E4

D4

E3D3 AE422

E6

D6

E5D5 AE422

C6

B6

C5B5 AE422

E8

D8

E7D7 AE422

C8

B8

C7B7 AE422

B1

AE510

B1

AE510

B1

AE510

B1

F4 AE422

BATHROOM 243A

D1

D2

E1

E2

BATHROOM 245A

D4

BATHROOM 245A

E4

B1

AE510

B1

AE510

F8

F6

F7F5 AE422

TOILET 258

F5

F7

F8

GENERAL CONSTRUCTION NOTES

AE501

SOILED UTL/HOLDING 228

F4

F4

AE502

F4

AE502

C1

AE510

ABBREVIATIONS:

C/C CONTRACTOR FURNISHED/CONTRACTOR INSTALLED

V/C VA FURNISHED/CONTRACTOR INSTALLED V/V VA FURNISHED/ VA INSTALLED

BATHROOM ACCESSORY LEGEND

ID # DESCRIPTION

PROVIDED/

INSTALLED

BLOCKING

REQUIRED

A01

DISPENSER, PAPER TOWEL, STAINLESS STEEL, SURFACE

MOUNTED

V/C YES

A02

DISPENSER, SOAP

V/C NO

A03

42" GRAB BAR, 1 1/4" DIAMETER STAINLESS STEEL, WHEELCHAIR

ACCESSIBLE

C/C YES

A04

36" GRAB BAR, 1 1/4" DIAMETER STAINLESS STEEL, WHEELCHAIR

ACCESSIBLE

C/C YES

A05

24" GRAB BAR, 1 1/4" DIAMETER, WHEELCHAIR ACCESSIBLE

C/C YES

A06

24" UP-SWINGING GRAB BAR, 1 1/4" DIAMETER, STAINLESS

STEEL, WHEELCHAIR ACCESSIBLE

C/C YES

A07

18" VERTICAL GRAB BAR, 1 1/4" DIAMETER STAINLESS STEEL

C/C YES

A08

MIRROR, FLOAT GLASS, WITH WOOD FRAME (18"W X 30" H)

C/C NO

A09 NURSE CALL C/C NO

A10

ROD, SHOWER, WITH CURTAIN

C/C NO

A11

SHOWER, HANDHELD

C/C NO

A12

HOOK, GARMENT, DOUBLE

C/C YES

A13 NOT USED - -

A14 RECESSED CABINET C/C YES

A15 NOT USED

A16 NOT USED - -

A17

MEDICINE CABINET, REFER TO DETAIL F3/AE502 UNLESS NOTED

OTHERWISE.

- YES

A18 TOILET TISSUE DISPENSER C/C YES

A19 24" TOWEL BAR C/C YES

A20 36" TOWEL BAR C/C YES

A21 WALL MOUNTED VANITY FIXTURE REFER TO EL121 C/C NO

FLOOR PLAN LEGEND

PARTITION TYPE - PARTITION IS

TYPE "A" UNLESS OTHERWISE

NOTED. REFER TO SHEET GI100

FOR DETAILS

XX

DOOR NUMBER

ROOM NAME

REFER TO AE421, AE422,

AE423, AND AE424 FOR

ELEVATIONS

CORNER GUARD- REFER TO

AE502 FOR DETAILS

END GUARD- REFER TO AE502

FOR DETAILS

CG1

EG

FIRE EXTINGUISHER CABINET

REFER TO SPECIFICATIONS

FEC

EXISTING WALL

NEW WALLS

PATIENT BED CENTERLINE

C

L

FD

FLOOR DRAIN

WALL PROTECTION. REFER TO

DETAIL B9/AE502

WP1

WALL PROTECTION. REFER TO

DETAIL C9/AE502

WP2

WALL PROTECTION. REFER TO

DETAIL B8/AE502

WP3

1. DO NOT SCALE DRAWINGS. WORK FROM DIMENSIONS SHOWN. IF ADDITIONAL INFORMATION

IS NEEDED, OR WHERE DRAWINGS OR DRAWING SCALE APPEAR TO CONFLICT WITH

INDICATED DIMENSIONS, BRING TO THE ATTENTION OF THE ARCHITECT FOR REVIEW.

2. COORDINATE SCHEDULE OF OVERALL CONSTRUCTION AND DAY-TO-DAY CONSTRUCTION

OPERATIONS WITH OWNER'S SCHEDULE REQUIREMENTS.

3. FLOOR PLAN DRAWINGS ARE COMPOSITES OF EXISTING CONSTRUCTION TO REMAIN AND

NEW CONSTRUCTION. EXISTING CONSTRUCTION IS SHOWN IN LIGHTER, OUTLINE FORM.

NEW CONSTRUCTION IS INDICATED WITH HEAVIER LINEWORK AND MAY ADDITIONALLY BE

IDENTIFIED BY NOTE, KEYNOTE, LARGER SCALE DETAIL REFERENCE, OR MATERIAL PATTERN

(REFER ALSO TO LEGEND).

4. ALL WALL DIMENSIONS ARE TO FINISH FACE OF WALL UNLESS NOTED OTHERWISE

5. DOCUMENTS ARE BASED ON VA'S RECORD DRAWINGS AND LIMITED FIELD SURVEY. FIELD

VERIFY ALL PROJECT CONDITIONS PRIOR TO THE START OF, AND AS NEEDED DURING THE

COURSE OF, NEW CONSTRUCTION WORK. BRING ANY DISCREPANCIES WHICH MAY

SIGNIFICANTLY AFFECT NEW CONSTRUCTION WORK TO THE ATTENTION OF THE ARCHITECT

FOR REVIEW.

6. KEEP MEANS OF EGRESS OPEN, PROPERLY ILLUMINATED, AND FREE OF OBSTRUCTIONS AT

ALL TIMES.

7. WHERE NEW WALL CONSTRUCTION ABUTS EXISTING, IN-LINE, ON PLANS, DIRECTLY ALIGN

NEW FINISH WALL SURFACE(S) WITH EXISTING.

8. ALL WOOD BLOCKING AND BACKING SHALL BE FIRE-RETARDANT TREATED, UNLESS NOTED

OTHERWISE.

9. KEEP CONSTRUCTION NOISE TO A MINIMUM.

10. NO SMOKING IS ALLOWED INSIDE THE EXISTING BUILDING, INCLUDING AT THE

CONSTRUCTION AREA.

11. PATCH AND REPAIR DENTS, CRACKS, HOLES, AND/OR OTHER UNEVEN SURFACE CONDITIONS

IN EXISTING CONSTRUCTION TO REMAIN.

12. VERIFY THE DIMENSIONS, LOCATIONS, ELEVATIONS AND ARRANGEMENT OF ALL ITEMS

ASSOCIATED WITH INSTALLATION OF EQUIPMENT AND RELATED MECHANICAL AND

ELECTRICAL WORK.

13. NOTIFY THE OWNER AND ARCHITECT OF ANY CODE AND/OR CONSTRUCTION DEFICIENCIES

DISCOVERED OR UNCOVERED IN THE COURSE OF CONSTRUCTION OPERATIONS.

14. THE EXISTING BUILDING, AND ITS SUBSEQUENT CONSTRUCTION MODIFICATIONS, ARE

ASSUMED TO BE IN FULL COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS IN

EFFECT AT THE TIME OF CONSTRUCTION.

15. PATCH EXISTING FLOOR OPENINGS AFTER DEMO OF EXISTING MECHANICAL AND PLUMBING

SHAFTS. REFER TO DETAIL F1/AE503.

16. ALL WALLS SHALL EXTEND TO DECK ABOVE, UNLESS NOTED OTHERWISE. REFER TO TYPICAL

WALL TYPES.

17. WHERE EXISTING WALLS ARE INDICATED AS RATED WALLS, SEAL ALL PENETRATIONS AND

OPENINGS WITH FIRE STOPPING TO MAINTAIN INDICATED RATING. FIELD VERIFY.

18.EXISTING FLOOR IS FIRE RATED. SEAL ALL PENETRATIONS AND OPENINGS WITH FIRE

STOPPING TO MAINTAIN INDICATED RATING.

19.PROVIDE TEMPORARY DUST PARTITIONS AT FIRST AND SECOND FLOOR AND OTHER

OCCUPIED AREAS AS REQUIRED BY CONSTRUCTION WORK. REFER TO TYPICAL DETAILS ON

DRAWING.

20.PROVIDE BLOCKING/METAL SUPPORT STRAPS IN PARTITIONS FOR EQUIPMENT INSTALLATION

(I.E. GRAB BARS, TV MONITORS ETC.) REFER TO DRAWINGS FOR LOCATIONS.

21.VERIFY AND COORDINATE CLEAR CHASE SPACE REQUIREMENTS WITH WALL LOCATIONS FOR

WATER CLOSET AT EACH TOILET AND MECHANICAL AND ELECTRICAL. DUCTS, CONDUITS AND

PIPING WITH EXISTING STRUCTURE AND EXISTING UTILITIES BELOW. CHASE WALL

LOCATIONS SHALL BE ADJUSTED AS REQUIRED TO ALLOW FOR PROPER INSTALLATION

THROUGH EXISTING STRUCTURAL CONCRETE FLOOR SLAB. NOTIFY ARCHITECT PRIOR TO

PROCEEDING. EXISTING UTILITIES BELOW MAY HAVE TO BE REWORKED FOR NEW

CONSTRUCTION.

22. PROVIDE CEMENT BOARD AT ALL SHOWERS AND WET WALLS, TYPICAL.

23. EXISTING CLAY TILE AND PLASTER COLUMN AND STEAM PIPING ENCLOSURE TO REMAIN AT

EXTERIOR WALL COLUMNS. VERIFY EACH LOCATION. REPORT ANY DISCREPANCY TO

ARCHITECT.

24. REFER TO SHEET AE431, AE501 FOR TYPICAL BUILT-UP BATHROOM FLOOR INFORMATION.

25. REFER TO SHEET IN102 FOR TYPICAL WALL TILE LAYOUT DESIGN IN RESIDENT BATHROOMS.

A4

AE502

E1

AE502

A6

AE502

XXX

C2

AE502

http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com http://www.ssoe.com

252A

C

C

C

254A

253A

CHARTING

BEDROOM

SW

PARLOR/DEN

BEDROOM

HAC

CLEAN

LINEN

BEDROOM-

BARIATRIC

SUITE

PASSAGE

C38

CORRIDOR

C37

C37

252A

C

C

C

254A

253A

S2-3

F

E

C

C

L

C

L

C

L

Ø

2'-1" 5'-0" 2'-11"

2'-4"

4'-5"

3'-0"

4'-9" 5'-0"

WC

LAV

SHOWER

WC

LAV

LAV

WC

SHOWER

EXISTING

SHAFT

EXISTING

SHAFT

1'-10"

WALL

MOUNTED

CHARGING

STATION

A01

A14

A06

A06

A01

A14

A06

A01

A14

SAFETY GLAZING SECURITY FILM - INSTALL

ON INSIDE FACE OF EXISTING GLAZING

C4

C3

C3

C3

C3

C3

C3

B1

B1

A1

A3

A2

A

A

BATHROOM

BARIATRIC

252A

BATHROOM

253A

10'-4 3/4"

6'-8 1/4" 4'-9" 3'-0"

BATHROOM

254A

6'-5 3/4"

4'-11"

ALIGN WALL WITH

COLUMN FURRING

TV

TV

BATHROOM

254A

PROVIDE PRIVACY

FILM ON BATHROOM

WINDOWS (TYPICAL)

CLOSET

CLOSET

CLOSET

A18

A18

A18

CG1

CG1

CG1

CG1

CG1

CG1

CG1

TV

FD

C3

FD

FD

FD

FD

C2

C3

CG1

CG1

EG-1

WP3

4'-0"

SERVICE SINK

RE: PLUMBING

ADA THRESHOLD

(TYPICAL)

C3

ADA THRESHOLD

(TYPICAL)

REFERENCE

DETAIL F7/AE501

ADA THRESHOLD

(TYPICAL)

REFERENCE

DETAIL E7/AE501

Ø6'-4"

WP1

WP1

WP1

WP3

WP3

WP3

WP3

WP3

NORTH

A14

A08

A02

A21

A10

A05

A20

3'-0" 2'-0"

6"

3'-0" SHOWER WIDTH

BASE

REFER TO FINISH

SCHEDULE

SOUTH

A06

A09

A03

A10

A18

EQUAL EQUAL

BASE

REFER TO FINISH

SCHEDULE

A10

A11

A07

A05

A12

A06

A09

A18

BASE

REFER TO FINISH

SCHEDULE

STOP SIDESPLASH AT

WINDOW FRAME

PLASTIC LAMINATE SIDE

PANEL

EXISTING WINDOW WITH

NEW PRIVACY WINDOW

FILM AND SAFETY

GLAZING SECURITY FILM

A01

A21

BASE

REFER TO FINISH

SCHEDULE

A01

A12

2'-0"

PLASTIC

LAMINATE

SIDE PANEL

A21

A06

A09

A05

A10

A11

A18

A03

A09

A10

A06

EQUAL EQUAL

A14

A08

A02

A21

A11

A05

A20

2'-0" 3'-0"

NORTH

A01

A12

1'-6"

A21

BASE

REFER TO FINISH

SCHEDULE

EAST SOUTH

A03

A09

A10

EQUAL EQUAL

BASE

REFER TO FINISH

SCHEDULE

A06

A20

A10

A07

A18

3'-0" SHOWER WIDTH

6"

BASE

REFER TO FINISH

SCHEDULE

A14

A08

A02

A21

A09

A06

2'-0" 3'-0"

BASE

REFER TO FINISH

SCHEDULE

234A

234A

C

236C

236A

F E

C

C

L

234A

LOCKER

ROOM

BEDROOM

BATH

236A

SHOWER RM

STAFF

TOILET

234A

CORRIDOR

C30

12'-0 1/2"9'-4"

WC

LAV

SHOWER

A01

A14

EXISTING

SHAFT

A06

WC

LAV

2'-8"

S1

S1

S2

S2

C3

A2

S2

A3

A3

SAFETY GLAZING

FILM

EXISTING

SHAFT

ALIGN WALL WITH

EXISTING SHAFT

ALIGN WALL WITH

EXISTING SHAFT

10'-8 1/2"

COAT HOOKS

C L

O S

E T

PROVIDE PRIVACY

FILM ON TOILET

ROOM WINDOW

A18

CG1

CG1

CG1

CG1

10'-10 1/4" 10'-1 3/4"

ADA THRESHOLD

(TYPICAL) REFER TO

DETAIL F7/AE501

TV

FD

FD

FD

FD

ADA THRESHOLD

(TYPICAL) REFER

TO DETAIL

F7/AE501

PRIVACY

CURTAIN AND

TRACK

A01

A4

S1

LOCKERS

LAV

FD

EQ EQ

SHOWER

CONTROLS

Ø

Ø

WP1

8'-0" 8'-7 1/2"

WP2

WP3

WP3

A2

A03

A09

A10

A18

EQUAL EQUAL

A10

A11

A07

A05

A20

6"

3'-0" SHOWER WIDTH

A12

A01

PLASTIC

LAMINATE

SIDE PANEL

A14

A08

A02

A21

A10

A05

A09

A06

3'-0" 2'-0"

A18

WALL

TILE

1'-9" 2'-8 3/4" 1'-9"

A02

A21

A08

FINISHED

END PANEL

BASE - REFER TO

FINISH SCHEDULE

GYPSUM BOARD

CEILING DROP

A12

A11

A07

A03

EQ

A01

EQ

WALL

TILE

A06

BASE

REFER TO FINISH

SCHEDULE

A18

WALL

TILE

A09

A06

WALL

TILE

A18

A01

A12

SCHEDULED BASE

EXISTING WINDOW WITH

NEW PRIVACY WINDOW FILM

A07

A03

A06

A18

A08

A02

A21

A02

NEW PRIVACY WINDOW FILM

METAL LOCKERS

REFER TO AE503

SLOPED TOP

BASE

REFER TO FINISH

SCHEDULE

ADJUSTABLE

COUNTER BY OWNER

HAT AND

COAT

HOOKS

BASE

REFER TO

FINISH

SCHEDULE

LOCKERS

SSOE, Inc.

Project #

Troy, MI 48084

Suite 260

T 248-643-6222

1050 Wilshire Drive

015-02007-00

SCHEMATIC SUBMISSION - NOT FOR CONSTRUCTION

100% BID DOCUMENT SUBMISSION

95% CONSTRUCTION DOCUMENTS

DESIGN DEVELOPMENT - NOT FOR CONSTRUCTION

SCHEMATIC DESIGN_REV, MOD P00001 SUBMISSION

95% CONSTRUCTION DOCUMENTS SUBMISSION

NOT FOR CONSTRUCTION

F1

C1AE503

C3AE503

AE503

BATHROOM 252A

1/4" = 1'-0"AE423

G3

G4

BATHROOM 253A

BATHROOM 253A

BATHROOM 254A

A3

A4

B3

B4

E4

D4

E3D3 AE423

B4

A4

B3A3 AE423

G4

F4

G3F3 AE423

B2

AE423

B1

AE510

B1

AE510

B1

AE510

B3,D3

AE501

B3,D3

B6

G8

F8

G7F7 AE423

C3AE503

E5D5

D6

AE423

BATHROOM 236A

F8

G7 BATHROOM 236A

G8

SHOWER 235

D5

D6

E6

AE511

STAFF TOILET 234A

G5

G6

LOCKER ROOM 234

E8

D8

E8

AE423

F5 G5

G6

F6

AE423

GENERAL CONSTRUCTION NOTES

CHARTING 250

B2

F8

AE510

B1

AE510

B6

TYPICAL

LOCKER ROOM 234

D8

F1

AE501

F4

AE502

E5

AE503

ABBREVIATIONS:

C/C CONTRACTOR FURNISHED/CONTRACTOR INSTALLED

V/C VA FURNISHED/CONTRACTOR INSTALLED V/V VA FURNISHED/ VA INSTALLED

BATHROOM ACCESSORY LEGEND

ID # DESCRIPTION

PROVIDED/

INSTALLED

BLOCKING

REQUIRED

A01

DISPENSER, PAPER TOWEL, STAINLESS STEEL, SURFACE

MOUNTED

V/C YES

A02

DISPENSER, SOAP

V/C NO

A03

42" GRAB BAR, 1 1/4" DIAMETER STAINLESS STEEL, WHEELCHAIR

ACCESSIBLE

C/C YES

A04

36" GRAB BAR, 1 1/4" DIAMETER STAINLESS STEEL, WHEELCHAIR

ACCESSIBLE

C/C YES

A05

24" GRAB BAR, 1 1/4" DIAMETER, WHEELCHAIR ACCESSIBLE

C/C YES

A06

24" UP-SWINGING GRAB BAR, 1 1/4" DIAMETER, STAINLESS

STEEL, WHEELCHAIR ACCESSIBLE

C/C YES

A07

18" VERTICAL GRAB BAR, 1 1/4" DIAMETER STAINLESS STEEL

C/C YES

A08

MIRROR, FLOAT GLASS, WITH WOOD FRAME (18"W X 30" H)

C/C NO

A09 NURSE CALL C/C NO

A10

ROD, SHOWER, WITH CURTAIN

C/C NO

A11

SHOWER, HANDHELD

C/C NO

A12

HOOK, GARMENT, DOUBLE

C/C YES

A13 NOT USED - -

A14 RECESSED CABINET C/C YES

A15 NOT USED

A16 NOT USED - -

A17

MEDICINE CABINET, REFER TO DETAIL F3/AE502 UNLESS NOTED

OTHERWISE.

- YES

A18 TOILET TISSUE DISPENSER C/C YES

A19 24" TOWEL BAR C/C YES

A20 36" TOWEL BAR C/C YES

A21 WALL MOUNTED VANITY FIXTURE C/C NO

FLOOR PLAN LEGEND

PARTITION TYPE - PARTITION IS

TYPE "A" UNLESS OTHERWISE

NOTED. REFER TO SHEET GI100

FOR DETAILS

XX

DOOR NUMBER

ROOM NAME

REFER TO AE421, AE422,

AE423, AND AE424 FOR

ELEVATIONS

CORNER GUARD- REFER TO

AE502 FOR DETAILS

END GUARD- REFER TO AE502

FOR DETAILS

CG1

EG

FIRE EXTINGUISHER CABINET

REFER TO SPECIFICATIONS

FEC

EXISTING WALL

NEW WALLS

PATIENT BED CENTERLINE

C

L

FD

FLOOR DRAIN

WALL PROTECTION. REFER TO

DETAIL B9/AE502

WP1

WALL PROTECTION. REFER TO

DETAIL C9/AE502

WP2

WALL PROTECTION. REFER TO

DETAIL B8/AE502

WP3

1. DO NOT SCALE DRAWINGS. WORK FROM DIMENSIONS SHOWN. IF ADDITIONAL INFORMATION

IS NEEDED, OR WHERE DRAWINGS OR DRAWING SCALE APPEAR TO CONFLICT WITH

INDICATED DIMENSIONS, BRING TO THE ATTENTION OF THE ARCHITECT FOR REVIEW.

2. COORDINATE SCHEDULE OF OVERALL CONSTRUCTION AND DAY-TO-DAY CONSTRUCTION

OPERATIONS WITH OWNER'S SCHEDULE REQUIREMENTS.

3. FLOOR PLAN DRAWINGS ARE COMPOSITES OF EXISTING CONSTRUCTION TO REMAIN AND

NEW CONSTRUCTION. EXISTING CONSTRUCTION IS SHOWN IN LIGHTER, OUTLINE FORM.

NEW CONSTRUCTION IS INDICATED WITH HEAVIER LINEWORK AND MAY ADDITIONALLY BE

IDENTIFIED BY NOTE, KEYNOTE, LARGER SCALE DETAIL REFERENCE, OR MATERIAL PATTERN

(REFER ALSO TO LEGEND).

4. ALL WALL DIMENSIONS ARE TO FINISH FACE OF WALL UNLESS NOTED OTHERWISE

5. DOCUMENTS ARE BASED ON VA'S RECORD DRAWINGS AND LIMITED FIELD SURVEY. FIELD

VERIFY ALL PROJECT CONDITIONS PRIOR TO THE START OF, AND AS NEEDED DURING THE

COURSE OF, NEW CONSTRUCTION WORK. BRING ANY DISCREPANCIES WHICH MAY

SIGNIFICANTLY AFFECT NEW CONSTRUCTION WORK TO THE ATTENTION OF THE ARCHITECT

FOR REVIEW.

6. KEEP MEANS OF EGRESS OPEN, PROPERLY ILLUMINATED, AND FREE OF OBSTRUCTIONS AT

ALL TIMES.

7. WHERE NEW WALL CONSTRUCTION ABUTS EXISTING, IN-LINE, ON PLANS, DIRECTLY ALIGN

NEW FINISH WALL SURFACE(S) WITH EXISTING.

8. ALL WOOD BLOCKING AND BACKING SHALL BE FIRE-RETARDANT TREATED, UNLESS NOTED

OTHERWISE.

9. KEEP CONSTRUCTION NOISE TO A MINIMUM.

10. NO SMOKING IS ALLOWED INSIDE THE EXISTING BUILDING, INCLUDING AT THE

CONSTRUCTION AREA.

11. PATCH AND REPAIR DENTS, CRACKS, HOLES, AND/OR OTHER UNEVEN SURFACE CONDITIONS

IN EXISTING CONSTRUCTION TO REMAIN.

12. VERIFY THE DIMENSIONS, LOCATIONS, ELEVATIONS AND ARRANGEMENT OF ALL ITEMS

ASSOCIATED WITH INSTALLATION OF EQUIPMENT AND RELATED MECHANICAL AND

ELECTRICAL WORK.

13. NOTIFY THE OWNER AND ARCHITECT OF ANY CODE AND/OR CONSTRUCTION DEFICIENCIES

DISCOVERED OR UNCOVERED IN THE COURSE OF CONSTRUCTION OPERATIONS.

14. THE EXISTING…