- 6110--36C249-20-AP-2387 - 626-21-1-4138-0002, Triennial - York Electrical Distribution Testing
- Solicitation number
- 36C24920Q0383
About this file
This combined synopsis/solicitation seeks quotations for electrical distribution testing, maintenance, and inspection services at the Alvin C. York VA Medical Center in Murfreesboro, Tennessee. The solicitation requires vendors to provide testing, maintenance, inspection, and repair services for electrical equipment including switchgear, transformers, automatic transfer switches, panel boards, generators, and associated components. Vendors must be experienced electrical contractors with NETA-certified technicians and provide all tools, equipment, and materials to perform maintenance testing in accordance with NETA standards. Quotes are due by September 8, 2020 and award will be made to the lowest-priced technically acceptable vendor. The period of performance is December 1, 2020 through March 31, 2021. The solicitation is set aside for SDVOSB and has an estimated value of $150,000.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24920Q0383 0003.docx | DOCX document | |
| 36C24920Q0383 0001_2.docx | DOCX document | |
| 36C24920Q0383 0001_1.docx | DOCX document | |
| Attachment 2 G W MV ATS inventory.pdf | ||
| Copy of Attachment 3 EPSS ATS Inventory.xlsx | XLSX spreadsheet | |
| Copy of Attachment 1 Equipment Inventory.xls | XLS spreadsheet | |
| 36C24920Q0383.docx | DOCX document | |
| Attachment 4 Lightning Suppression Bldg list.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Contract Opportunity Amendment to a Previous Combined Solicitation
PRODUCT SERVICE CODE
SUBJECT
CONTRACTING OFFICE'S
ZIP-CODE
SOLICITATION NUMBER
BASE NOTICE TYPE
RESPONSE DATE/TIME/ZONE
ARCHIVE
DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
SET-ASIDE
NAICS CODE
CONTRACTING OFFICE
ADDRESS
POINT OF CONTACT
(POC Information Automatically Filled from User Profile Unless Entered)
DESCRIPTION
See Attachment
AGENCY'S URL
URL DESCRIPTION
AGENCY CONTACT'S EMAIL
ADDRESS
EMAIL DESCRIPTION
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
GENERAL INFORMATION
PLACE OF PERFORMANCE
* = Required Field Contract Opportunity Amendment to a Previous Combined Solicitation 36C249-20-AP-2387 - 626-21-1-4138-0002, Triennial - York Electrical Distribution Testing 37129 36C24920Q0383 09-08-2020 8:00am
CENTRAL TIME, CHICAGO, USA
N
SDVOSBC
811310 Department of Veterans Affairs Network Contracting Office 9 (90C)
NCO 9
1639 Medical Center Parkway, Suite 400 Murfreesboro TN 37129 Contracting Officer Crystal Baird crystal.baird@va.gov 615-225-5427 Alvin C. York VA Medical Center 3400 Lebanon Pike Murfreesboro
TN
37129 United States The purpose of this amendment is to respond to vendor questions.
1) Name (and contact info if available) of the factory trained and certified field tech/engineer that previously worked on the EPSS ATS at the facility. Emmett Yancey (Emmett.yancey@asco-power.com) 678-641-0138
2) Existing electrical drawings (i.e. one-lines, etc.) An electronic version is not available to share via email.
3) Most recent Arc Flash study. An electronic version is not available to share via email.
4) Ref. G & W Electric, repair voltage sensing problem on PMSG-3 (pg 6 of 15 under ** note): Is there already a diagnosed. assessed or suspected cause of the voltage sensing problem? If not, please provide additional information on what is known about the problem. Initial assessment has been made by VA electricians, appears the voltage sensing relay is defective, contractor will need to verify issue prior to performing any repair work.
5) Ref. Repair motor circuit failure on PMSG-8 (pg 6 of 15 under ** note): Is there already a diagnosed, assessed or suspected cause of the failure? If not, please provide additional information on what is known about the problem, such as a known issue with the control signal, power to load or bad motor? No diagnosis has been performed, control board indicates motor failure, motor will not operate in either open or closed position, further troubleshooting is needed to identify exact fault before the repair can be accomplished.
6) How will payment be delivered? Payments for this work shall be as follows;
• 10% payment upon completion of infrared testing with notification of discrepancies found and manhole IR survey, functional test and list of discrepancies.
• 10% payment upon completion of all automatic transfer switches associated with the EPSS.
• 15% payment upon completion of the lightning suppression systems and an accepted report of deficiencies.
• 50% payment upon completion of electrical equipment testing, may be divided into more than 1 monthly period due to the time required to perform testing.
• 15% payment upon receipt and acceptance of the required reports.