36C24918R0163-009.pdf

PDF 288 KB Posted

Attached to
Construct Parking Garage on West Lot - Project 614-320 Federal contract opportunity
Solicitation number
36C24918R0163
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9

About this file

36C24918R0163 Fire Protection.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Construct Parking Garage on West Lot - Project 614-320, newest first.
File Type Posted
36C24918R0163-00004000.docx DOCX document
36C24918R0163-00003006.docx DOCX document
36C24918R0163-00003008.pdf PDF
36C24918R0163-00003007.pdf PDF
36C24918R0163-00002000.docx DOCX document
36C24918R0163-00001000.docx DOCX document
36C24918R0163-016.pdf PDF
36C24918R0163-008.pdf PDF
36C24918R0163-015.xlsx XLSX spreadsheet
36C24918R0163-014.docx DOCX document
36C24918R0163-006.pdf PDF
36C24918R0163-010.pdf PDF
36C24918R0163-003.xlsx XLSX spreadsheet
36C24918R0163-007.pdf PDF
36C24918R0163-004.pdf PDF
36C24918R0163-005.pdf PDF
36C24918R0163-011.pdf PDF
36C24918R0163-002.docx DOCX document
36C24918R0163-012.pdf PDF
36C24918R0163-013.pdf PDF
36C24918R0163-001.docx DOCX document
36C24918R0163-000.docx DOCX document
Show all 22

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STOP

MOTORCYCLE SPACES

MOTORCYCLE SPACES

1 2 3 4 5 6 7 8 9

A

B

ELEC

IT

SECURITY

STORAGE

STAIR 2

GRADE

FLOOR

WALL

SIAMESE

FIRE DEPARTMENT CONNECTION

WALL PLATE

(TYPICAL)

PIPE TAP FOR BALL

DRIP VALVE

18" TO 48"

DRAIN PIPE TO EXTERIOR

DISCHARGE MIN 6" ABOVE

FINISHED GRADE.

HORIZONTAL

MOUNTED

BALL DRIP VALVE

1 2 3 4 5 6 7 8 9

A

B

2 3

1 2 3 4 5 6 7 8 9

A

B

2 3

STAIR 2

STANDPIPE

DRAIN TO

OUTSIDE

CENTER 2

STANDPIPE

STAIR 1

STANDPIPE

FDC WITH BALL

DRIP VALVE

2" MAIN DRAIN TO

3" FLOOR DRAIN

DRAIN TO

GARAGE DRAIN

2-1/2" HOSE VALVE

CONNECTION

DRAIN

TO OUTSIDE

DRAIN TO

GARAGE DRAIN

CENTER 1

STANDPIPE

Drawing Title

Approved for Design Concept:

Project Title

Date

Location

Checked By:

Building Number

Project Number

Drawing Number

Drawn By:

Revisions: Date

MEMPHIS, TN

o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

OFFICE OF

FACILITIES

MANAGEMENT

VA Project Number

FACILITY MANAGEMENT

DIVISION MANAGER

614-319

MEMPHIS VAMC

1030 JEFFERSON AVE, MEMPHIS, TN 38104

ARCHITECT/ENGINEERS:

MEP Engineer

APOGEE CONSULTING

GROUP

1151 Kildaire Farm Rd.

Suite 120 Cary, NC 27511

Tele: 919-858-7420

Functional Design

CARL WALKER INC.

3211 Internet Blvd., Suite 220 Frisco, TX 75034

Tele: 469-777-5143

905 N. CAPITOL AVE. SUITE 100 INDIANAPOLIS, IN. 46204

317.800.6388 WWW.GUIDONDESIGN.COM

SUSTAINABLE ARCHITECTURE + ENGINEERING

PROJECT LEAD

Architect, Structural Engineer, Civil Engineer

L:

\P ro je ct s

- E ng

\2

Pr oj ec ts \1

5-

2- G

D N

-V A

M em ph is

P ar ki ng

G ar ag e

TN

\D w g\

Xr ef s\

-4

M ec h- Pl um b

M od el .rv t

BID SET

FX101

ORDCC

FIRE SUPPRESSION PLAN

11/14/2016

15.1067CONSTRUCT PARKING GARAGE

ON WEST LOT

1" = 20'-0"FX101

1 FIRST FLOOR FIRE SUPPRESSION PLAN

KEY NOTE

1 PROVIDE SIAMESE FIRE DEPARTMENT CONNECTION ON EXTERIOR, 36"

ABOVE GRADE. PROVIDE DRAIN TO EXTERIOR. REFER TO DETAIL 5/FX101.

2 PROVIDE DRY STANDPIPE WITH 2-1/2" HOSE VALVE CONNECTIONS AT EACH

FLOOR. COORDINATE FINAL LOCATION WITH DOMESTIC WATER RISER.

3 ACCESS REQUIRED BETWEEN PARKING SPACES AND MUST BE ACCESSIBLE

FROM BOTH SIDES TO MEET TRAVEL DISTANCE REQUIREMENTS.

1" = 1'-0"FX101

5 WALL MOUNTED FIRE DEPARTMENT CONNECTION DETAIL

FIRE SUPPRESION GENERAL NOTES

9 ROUTE ALL PIPE TIGHT TO UNDERSIDE OF STRUCTURE.

10 PROVIDE DRAIN TO EXTERIOR SIZED PER REQUIREMENTS OF NFPA 14.

11 PROVIDE SIGN WITH HYDRAULIC DESIGN INFORMATION AS REQUIRED BY NFPA 14 IN APPROVED

LOCATION.

12 PROVIDE SIGNS ON ALL MAIN AND SECTIONAL CONTROL VALVES INDICATING PORTION OF THE

SYSTEM CONTROLLED BY THE VALVE PER REQUIREMENTS OF NFPA 14.

13 PROVIDE SIGN ON ALL CONTROL, DRAIN, AND TEST CONNECTION VALVES INDICATING THE

PURPOSE OF EACH VALVE PER REQUIREMENTS.

14 PROVIDE SIGNS FOR EACH HOSE CONNECTION NOT LOCATED IN AN EXIT STAIRWELL TO IDENTIFY THE LOCATION OF THE HOSE CONNECTION IN AN APPROVED MANNER PER THE REQUIREMENTS OF

THE NFPA 14 AND THE NFPA 170.

FIRE SUPPRESION GENERAL NOTES

1 DESIGN, INSTALLATION AND TESTING SHALL BE IN ACCORDANCE WITH NFPA 14 FOR CLASS I MANUAL DRY STAND PIPE SYSTEM EXCEPT AS MODIFIED BY SPECIFICATION SECTION 21 12 00.

2 CONTRACTOR SHALL PROVIDE DESIGN, MATERIALS, EQUIPMENT AND INSTALLATION, INSPECTION

AND TESTING OF A COMPLETE AND READY FOR OPERATION FIRE-SUPPRESSION MANUAL DRY

STANDPIPE SYSTEM AS REQUIRED BY NFPA 14.

3 SIZE STANDPIPES TO PROVIDE 100 PSIG RESIDUAL PRESSURE AT REQUIRED FLOW AT THE MOST

REMOTE CONNECTIONS.

4 CONNECTION SHALL BE THREADED TO MATCH THOSE ON THE LOCAL FIRE PROTECTION SERVICE.

5 ALL DEVICES AND EQUIPMENT SHALL BE LISTED FOR THE INTENDED PURPOSE.

6 PROVIDE MANUAL DRY STANDPIPE, HYDRAULICALLY SIZED PER REQUIREMENTS OF NFPA 14

(MINIMUM 4") WITH 2-1/2" HOSE VALVE CONNECTED AT EACH FLOOR MOUNTED WITH CENTER OF HOSE VALVE LOCATED BETWEEN 3 AND 5 FEET ABOVE FINISHED FLOOR (AFF). ALL HOSE VALVE CONNECTIONS AND STATIONS ARE TO BE LOCATED CLEAR OF OBSTRUCTIONS AND SHALL NOT BE

OBSTRUCTED BY ANY CLOSED OR OPEN STAIRWELL DOOR(S) OR OTHER OBJECTS.

7 PROVIDE FIRE DEPARTMENT CONNECT (FDC) ON EXTERIOR ABOVE GRADE WITHIN 100' OF

NEAREST HYDRANT, VISIBLE AND RECOGNIZABLE FROM THE STREET OR NEAREST FIRE

DEPARTMENT ACCESS. FDC TO BE 18" - 48" ABOVE GRADE MEASURED TO CENTER, PROVIDE SIGN INDICATING PRESSURE REQUIRED AT FDC TO MEET SYSTEM DESIGN DEMAND. PROVIDE THE SIZE, TYPE, AND LOCATION AS REQUIRED BY LOCAL FIRE PROTECTION SERVICE AND CAPACITY PER

REQUIREMENTS OF NFPA 14. PROVIDE SIGN AT EACH FDC LOCATION INDICATING "STANDPIPE -

MANUAL DRY SYSTEM" IN APPROVED LOCATION.

8 PROVIDE MINIMUM 2" MAIN DRAIN TO FLOOR DRAIN SIZED PER REQUIREMENTS OF NFPA 14.

1" = 20'-0"FX101

2 SECOND FLOOR FIRE SUPPRESSION PLAN

1" = 20'-0"FX101

3 THIRD FLOOR FIRE SUPPRESSION PLAN

FX101

4 FP RISERS

CMC

CMC Stamp