36C24918R0140-006.pdf
PDF 19 KB Posted
- Attached to
- IDIQ Small Construction Contracts NRM
- Solicitation number
- 36C24918R0140
About this file
36C24918R0140 P01-Drawing 4 - New Reflected Ceiling Plan.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24918D0149-000.docx | DOCX document | |
| 36C24918R0140-000002001.pdf | ||
| 36C24918R0140-000002000.docx | DOCX document | |
| 36C24918R0140-000001000.docx | DOCX document | |
| 36C24918R0140-000001001.pdf | ||
| 36C24918R0140-005.pdf | ||
| 36C24918R0140-002.pdf | ||
| 36C24918R0140-001.docx | DOCX document | |
| 36C24918R0140-008.pdf | ||
| 36C24918R0140-004.pdf | ||
| 36C24918R0140-007.pdf | ||
| 36C24918R0140-009.xlsx | XLSX spreadsheet | |
| 36C24918R0140-003.pdf | ||
| 36C24918R0140-00001000.docx | DOCX document | |
| 36C24918R0140-000.docx | DOCX document |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VHAMEMFONGL
Typewritten Text
GENERAL NOTES:
1. 9'-0" ACOUSTICAL CEILING, SEISMIC MOUNTING, 2'X2' USG 2110 RADAR WITH HEAVY DUTY SUSPENSION SYSTEM USG DONN DX/DXL26
2. CENTER NEW QUICK RESPONSE SPRINKLER HEAD IN CEILING TILE
3. CENTER NEW EGGCRATE EXHAUST GRILLE IN CEILING TILE
4. NEW 2'X2' LED VOLUMETRIC TROFFER LITHONIA 2VTL2 24L ADP D24 PWS 1836 LP850 NX USPOM, CONNECTED TO EXISTING CIRCUIT, NEW TOGGLE SWITCH
5. NEW 4" EVO A-SERIES LED, OPEN REFLECTOR, ALED 41/06 4PR 277 USPOM IN SOFFIT, CONNECTED TO EXISTING CIRCUIT, NEW TOGGLE SWITCH
File details come from the government source that posted it.