36C24818R0140-000.docx

DOCX document 15 KB Posted

Attached to
Replace Failing De-Aerating Tank Federal contract opportunity
Solicitation number
36C24818R0140
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8

About this file

36C24818R0140 36C24818R0140.docx

View the file

Other files for this federal contract opportunity

Other files attached to Replace Failing De-Aerating Tank, newest first.
File Type Posted
36C24818R0140-00001000.docx DOCX document
36C24818R0140-009.pdf PDF
36C24818R0140-008.docx DOCX document
36C24818R0140-004.doc DOC document
36C24818R0140-006.doc DOC document
36C24818R0140-001.docx DOCX document
36C24818R0140-010.pdf PDF
36C24818R0140-011.doc DOC document
36C24818R0140-005.docx DOCX document
36C24818R0140-007.doc DOC document
36C24818R0140-003.doc DOC document
36C24818R0140-012.doc DOC document
36C24818R0140-002.pdf PDF
Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FedBizOpps Presolicitation Notice

CLASSIFICATION CODE

SUBJECT

CONTRACTING OFFICE'S

ZIP-CODE

SOLICITATION NUMBER

RESPONSE DATE (MM-DD-YYYY)

ARCHIVE

DAYS AFTER THE RESPONSE DATE

RECOVERY ACT FUNDS

SET-ASIDE

NAICS CODE

CONTRACTING OFFICE

ADDRESS

POINT OF CONTACT

(POC Information Automatically Filled from User Profile Unless Entered)

DESCRIPTION

See Attachment

AGENCY'S URL

URL DESCRIPTION

AGENCY CONTACT'S EMAIL

ADDRESS

EMAIL DESCRIPTION

ADDRESS

POSTAL CODE

COUNTRY

ADDITIONAL INFORMATION

GENERAL INFORMATION

PLACE OF PERFORMANCE

* = Required Field FedBizOpps Presolicitation Notice Rev. March 2010 Z Replace Failing De-Aerating Tank 33410-6400 36C24818R0140 02-06-2018 N 236220 Department of Veterans Affairs West Palm Beach VA Medical Center 7305 North Military Trail Palm Beach Gardens FL 33410-6400 Deborah Murphy Department of Veterans Affairs West Palm Beach VA Medical Center 7305 N. Military Trail West Palm Beach, Florida 33410-6400

USA

deborah.murphy3@va.gov Contracting Officer

DESCRIPTION:

The scope of this project is to provide all design build services, labor, materials, tools, equipment, supervision, transportation, and all other resources necessary to remove and replace the failed de-aerating tank at the West Palm Beach VA Medical Center, Building 1 in accordance with the requirements of the project.

1. Tank replacement can be either in-place with the modified capacity listed below, or purchase a “packaged DA Tank” and consider relocating on the lower level. Both options shall include modified capacity:

a. Capacity 26,000 lbs./hr. water output

b. Water in, 110 degree f (160 degree f - 180 degree f normal)

c. Water out, 228 degree f

d. Operating Steam Pressure 5 psig

e. De-aeration to 0.005 cc/liter oxygen

f. Storage capacity, 102 cu. ft. minimum at overflow (20 minutes of capacity)

g. Construction, ASME Code for 50 psig

h. Maximum dimensions (TBD)

2. Includes controls and instruments as required to replace existing programmable loop AC controllers which are obsolete and no longer able to be repaired. It is anticipated that the last four AC controllers will be replaced with UPAC controller(s).

NCO 8 anticipates the award of a firm-fixed-price contract to provide design build services.

The magnitude of construction is between $500,000.00 and $1,000,000.00 The solicitation will be issued on or about December 18, 2017.

All information for this solicitation will be posted on the Federal Business Opportunities (FBO) web-site at www.fbo.gov All interested firms must be registered in the System for Award Management www.SAM.GOV and certified at U.S. Department of Veterans Affairs, Office of Small & Disadvantaged Business Utilization at www.vip.vetbiz.gov .

Product Service Code – Z1DA Green Environmental Management System (GEMS) - Contractors selected for award of this contract are expected to be good stewards of the environment by complying with federal, state and local environmental laws and other requirements such as medical center policy and project specifications. In addition contractors should incorporate pollution prevention and waste minimization into operations.

File details come from the government source that posted it.