36C24418B0287-00004000.docx
DOCX document 30 KB Posted
- Attached to
- Upgrade Patient Environment NHCU #642-16-107
- Solicitation number
- 36C24418B0287
About this file
36C24418B0287 00004 36C24418B0287 00004.docx
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24418C0174-000.docx | DOCX document | |
| 36C24418B0287-00003002.pdf | ||
| 36C24418B0287-00003003.pdf | ||
| 36C24418B0287-00003001.pdf | ||
| 36C24418B0287-00003000.docx | DOCX document | |
| 36C24418B0287-00003005.pdf | ||
| 36C24418B0287-00003004.pdf | ||
| 36C24418B0287-00003006.pdf | ||
| 36C24418B0287-00002001.pdf | ||
| 36C24418B0287-00002000.docx | DOCX document | |
| 36C24418B0287-00001003.pdf | ||
| 36C24418B0287-00001004.pdf | ||
| 36C24418B0287-00001000.docx | DOCX document | |
| 36C24418B0287-00001002.pdf | ||
| 36C24418B0287-00001001.pdf | ||
| 36C24418B0287-002.pdf | ||
| 36C24418B0287-001.docx | DOCX document | |
| 36C24418B0287-003.pdf | ||
| 36C24418B0287-000.docx | DOCX document |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5. PROJECT NUMBER (if applicable)
CODE
7. ADMINISTERED BY
2.
AMENDMENT/MODIFICATION NUMBER
CODE
6. ISSUED BY
8. NAME AND ADDRESS OF CONTRACTOR
4. REQUISITION/PURCHASE REQ. NUMBER
3. EFFECTIVE DATE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED
PAGE
OF PAGES
10A. MODIFICATION OF
CONTRACT/ORDER NUMBER
10B. DATED
BPA NO.
1. CONTRACT ID CODE
FACILITY CODE
CODE
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
E. IMPORTANT:
is extended,
(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.
12. ACCOUNTING AND APPROPRIATION DATA
(REV.
11/2016) is required to sign this document and return ___________ copies to the issuing office.
is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO.
IN ITE
M 10A.
15C. DATE
SIGNED
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES
SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR
43.103(b).
RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes r eference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER
BY
Contractor
16C. DATE
SIGNED
14.
DESCRIPTION OF AMENDMENT/MODIFICATION
16B. UNITED STATES OF AMERICA
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME
AND TITLE OF SIGNER
16A. NAME AND TITLE OF CONTRACTING OFFICER
15B. CONTRACTOR/OFFEROR
STANDARD FORM 30
PREVIOUS EDITION NOT USABLE
Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
(Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) such as changes in paying office, appropriation date, etc.)
(If required)
(SEE ITEM 11)
(SEE ITEM 13)
(X)
CHECK
ONE
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS
OF SOLICITATIONS
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
(Signature of person authorized to sign) (Signature of Contracting Officer) 00004 05-14-2018 642-16-107 00244 Department of Veterans Affairs Network Contracting Office 4
00244 Department of Veterans Affairs Network Contracting Office 4
To all Offerors/Bidders
36C24418B0287 04-11-2018
X X X 17 May 2018 at 1:00PM local X The purpose of this amendment is to replace Spec Sectio n 22 40 00 para 2.8.C.1 a nd 2.9.B.1 a s follows:
Everett E Shaver, Jr., Contracting Officer VAMC Philadelphia – Upgrade Patient CLC Phase 1
Addendum __.
Specification Section 22 40 00, 2.8.C.1: Replace 2.8.C.1 with the following:
1. Faucet: Faucet shall be solid cast brass construction, chrome plated, with gooseneck spout with outlet terminating 7 inches above rim. Faucet shall be a deck mounted single hole electronic battery-operated sensor faucet with a dual-beam infrared sensor. The faucet shall be designed for patient care applications and compatible with handheld programming and adjustment controller. The faucet shall have dual supply for hot and cold-water service, powered by a 6 Volt Lithium CRP2 Battery (battery included), 3/8 inches OD copper supply tubes, and compatible with a hand held remote controller. Faucet shall be certified to NSF/ANSI 61, section 9 by CSA, NSF/ANSI 372 Low Lead Content compliant, be in accordance with ADA ANSI/ICC A 117.1 and ASME A112.18.1/CSA B125.1. Faucet shall be suitable for pressures from 20 to 125 psi, be rated for an operating range from 40 degrees F to 140 degrees F and include a 180 degree, high temperature system flush. Provide a 4-inch stainless steel cover plate with locating pin and mounting hardware. The faucet shall be capable of remote adjustments through a hand held remote controller as follows:
a. Through a handheld remote controller capable of programming multiple field adjustments. Field adjustments shall include, Running Modes which include a cleaning mode that will disable the faucet while being cleaned with adjustment range from 1 to minutes; Scrub Mode which activates faucet and continues to remain activated until completing the adjustable run time form 3 seconds to 180 seconds; Metering Mode allows for adjustment of running time from 3 to 180 seconds; Range and Sensing adjustments; routine hygiene flush programable from intervals of 1 to 168 hours and adjustable duration from 3 to 180 seconds and a water saver mode. Through the hand-held remote controller, shall have diagnostic capabilities that indicate malfunction and replacement required to correct the malfunction. for will allow Specification Section 22 40 00, 2.9.B.1: Replace 2.9.B.1 with the following:
1. Faucet: Faucet shall be solid cast brass construction, chrome plated, with gooseneck spout with outlet terminating 7 inches above rim. Faucet shall be a deck mounted single hole electronic battery-operated sensor faucet with a dual-beam infrared sensor. The faucet shall be designed for patient care applications and compatible with handheld programming and adjustment controller. The faucet shall have dual supply for hot and cold-water service, powered by a 6 Volt Lithium CRP2 Battery (battery included), 3/8 inches OD copper supply tubes, and compatible with a hand held remote controller. Faucet shall be certified to NSF/ANSI 61, section 9 by CSA, NSF/ANSI 372 Low Lead Content compliant, be in accordance with ADA ANSI/ICC A 117.1 and ASME A112.18.1/CSA B125.1. Faucet shall be suitable for pressures from 20 to 125 psi, be rated for an operating range from 40 degrees F to 140 degrees F and include a 180 degree, high temperature system flush. Provide a 4-inch stainless steel cover plate with locating pin and mounting hardware. The faucet shall be capable of remote adjustments through a hand held remote controller as follows:
a. Through a handheld remote controller capable of programming multiple field adjustments. Field adjustments shall include, Running Modes which include a cleaning mode that will disable the faucet while being cleaned with adjustment range from 1 to minutes; Scrub Mode which activates faucet and continues to remain activated until completing the adjustable run time form 3 seconds to 180 seconds; Metering Mode allows for adjustment of running time from 3 to 180 seconds; Range and Sensing adjustments; routine hygiene flush programable from intervals of 1 to 168 hours and adjustable duration from 3 to 180 seconds and a water saver mode. Through the hand-held remote controller, shall have diagnostic capabilities that indicate malfunction and replacement required to correct the malfunction. for will allow
End of Document