36C24220B0035-0001003.pdf
PDF Posted
- Solicitation number
- 36C24220B0035
About this file
This notice describes a federal solicitation for electrical upgrade work at a Department of Veterans Affairs medical center. The solicitation seeks bids for a service-disabled veteran-owned small business set-aside contract to improve electrical deficiencies in phases II A and B at the VA New Jersey Health Care System campus in East Orange, New Jersey. The work includes replacing service transformers and 5kV distribution switchgear, upgrading substations, replacing electrical panels in various campus buildings, and installing generator connections and temporary power sources at electrical vaults. The estimated cost range is $5-10 million. The response due date will be included in the solicitation, expected to be released on April 20, 2020. All bids must be submitted in hard copy and registered offerors must be verified as SDVOSBs in the Vendor Information Pages database at time of submission. The contract completion schedule is 730 calendar days.
36C24220B0035 0001 S02 Drawings 02-CIVIL.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24220B0035-0002000.docx | DOCX document | |
| 36C24220B0035-0001001.pdf | ||
| 36C24220B0035-0001005.pdf | ||
| 36C24220B0035-0001004.pdf | ||
| 36C24220B0035-0001000.docx | DOCX document | |
| 36C24220B0035-0001002.pdf | ||
| 36C24220B0035-020.pdf | ||
| 36C24220B0035-015.docx | DOCX document | |
| 36C24220B0035-021.pdf | ||
| 36C24220B0035-019.pdf | ||
| 36C24220B0035-017.pdf | ||
| 36C24220B0035-016.pdf | ||
| 36C24220B0035-018.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E
UG/E
UG/E
UG/E
UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E UG/E UG/E UG/E UG/E
UG/E
UG/E
UG
/E
UG
/E
UG/E
UG/E
UG/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG
/E
UG/E
UG/E UG/E UG/E UG/E UG/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG/E
UG/E
UG/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
D.C.
D
C
D
C
CONC. CURB
C
O N
C . C
U R
B
D
C
D.C.
D
.C
C O
N C
. C U
R B
CONC. CURB
C
O
N
C
U
R
B
C
O
N
C
C
U
R
B
C
O
N
R
B
C
O
N
R
B
C
O
N
C
C
U
R
B
CONC.
CURB
CONC.
CURB
CONC.
CURB
1 STORY MASONRY
BUILDING
O.H. CANOPY
O.H. CANOPY
O H
C
A N
O P
Y
STEPS
W/HANDRAIL
CONC. STEPS
CONC. WALL W/4' HIGH C.L.F.
CONC. WALL W/8' HIGH C.L.F.
BRICK WALL
BRICK WALL
S T
O N
E
W
A L L
BRICK WALL
CONC. WALL
CONC. WALL
HANDRAIL
10' HIGH C.L.F.
10' HIGH C.L.F.
8' HIGH IRON FENCE
8' HIGH IRON FENCE
STONE WALL
STONE WALL
C O
N C
. W A
L L
HANDRAIL
H
A
N
D
R
A
I
L
H A
N D
R A
I L
M
G
R
G A
T E
G A
T E
10' H
IG
H C
.L.F
G A
T E
S T
O N
E W
A L L
10' HIGH C.L.F. W/BARBED WIRE
H
I G
H
C
L F
W
B
A R
B E
D
W
I R
E
M
G
R
M
G
R
H
I G
H
L
F
O
N
B
L
O
K
W
A
L
L
FLAG POLE
(TYP.)
6' HIGH C.L.F.
E
O
P
E
O
P
CONC.
E.O.P.
E.O.P.
E
O
P
C O
N C
W
A L K
CONC. WALK
CONC. WALK
CONC. RAMP
CONC. WALK
C
O
N
L
K
C
O
N
C
W
A
L
K
CONC.
CONC. WALK
CONC.
MULTI-STORY
MASONRY
HOSPITAL
S
W
L
S.Y.L.
S W
L
S
R
L
C
R
O
S
S
W
A
L
K
YELLOW
STRIPING
S
Y
L
S
W
L
S
R
L
UG/E
UG/E
UG/E
UG/E
FOC
FOC
FOC
FOC
FOC
FO
C
FO
C
FO
C
EMH
RIM=251.58
W W
W W
W W
W
EMH
RIM=243.13
EMH
RIM=249.41
RIM=246.56
INV(A)=235.7
INV(B)=235.6
DMH
DMH
RIM=249.46
INV(A)=239.2
INV(B)=239.1
EMH
RIM=238.11
W W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
DMH
RIM=252.27
INV(A)=248.4
INV(B)=241.4
DMH
RIM=243.73
INV(A)=238.6
INV(B)=236.9
GRT=242.02
INV(A)=238.6
INV(B)=237.1
INV(C)=237.0
INV(D)=236.6
INV(E)=235.2
INV(F)=234.8
CB
DMH
RIM=256.36
INV(A)=251.9
INV(B)=248.7
NV(C)=248.5
INV(D)=242.1
FO
C
FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC
FOC
FOC FOC FOC
FO
C
FO
C
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GA
S
GA
S
GA
S
GRT=253.53
INV=250.7
CB
GRT=250.40
INV=247.2
CB
DMH
RIM=250.48
INV(A)=244.3
INV(B)=243.9
INV(C)=243.8
INV(D)=239.4
EMH
RIM=252.52
FOC FOC FOC FOC FOC
FOC
FOC
FOC
RIM=252.52
TC=251.13
GRT=250.45
INV=243.9
CB
TC=251.64
GRT=251.01
INV=244.7
CB
GRT=241.79
CB
GRT=246.76
BOS=243.8±
(FWD)
(NPV)
CB
FOC
FOC
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
INV=232.27
FES
INV=232.26
FES
RIM=251.04
EMH
RIM=251.22
DMH
RIM=254.15
INV(A)=249.5
INV(B)=247.8
15" S
TEEL
S
T
E
E
L
E
E
L
(D)
(A)
(B)
(C)
6" STEEL
(A)
E
E
L
S
T
E
E
L
E
E
L
S
T
E
E
L
R
C
P
(A)
(B)
12" STEEL
(A)
(B)
P
V
C
12" STEEL
C
6" PVC
6" PVC
(A)
(B)
(D)
(E)
(F)
(A)
(B) (B)
(A)
(C)
(B)
(D)
FDC
FDC
ELECTRICAL
EQUIPMENT
"DO NOT ENTER"
"WRONG WAY"
"DO NOT ENTER"
"WRONG WAY"
"NO PARKING
FIRE LANE"
"TOW AWAY ZONE"
"NO PARKING
FIRE LANE"
"TOW AWAY ZONE"
"STOP"
"ONE WAY"
"SPEED LIMIT 5"
"STEVEN GREGG DRIVE"
"URESKO DRIVE"
"ONE WAY"
"NO LEFT TURN"
"ONE WAY
DO NOT ENTER"
"WRONG WAY"
"CAMERA"
"ONE WAY"
"AMBULANCE PARKING
ONLY"
"NO PARKING
FIRE LANE"
C O
N T
A I N
E R
"DO NOT ENTER"
"WRONG WAY"
L.S.A.
T24
T2
T2
T2
T2
P15
P10
P18
P18
L.S.A.
CONC. RAMP
W/HANDRAIL
C
O
N
C
R
A M
P
GRASS
ASPHALT
PAVEMENT
ASPHALT
PAVEMENT
ASPHALT
PAVEMENT
GRASS
GRASS
ASPHALT
PAVEMENT
"VA MEDICAL CENTER"
E
O
C
TMH
TMH
C
O
N
T
A
I N
E
R
6" STEEL
(B)
(B)
RIM=254.92
TMH
T R
A
IL
E R
GRASS
CONC.
WALK
POW
POW
HANDRAIL
G R
A N
I T
E
W
A L L
G R
A N
I T
E
W
A L L
6" PVC STORM DRAIN
(SEE NOTE 3)
S W
L
S W
L
C
O
N
C
R
A M
P
H A
N D
R A
IL
H A
N D
R A
IL
CONC.
C
O
N
T
A
I N
E
R
C
O
N
T
A
I N
E
R
C
O
N
T
A
I N
E
R
E .O
.P
BUILDING
#24
ASPHALT
PAVEMENT
CONC. WALL
EMERGENCY
GENERATOR
E.O.C.
YELLOW STRIPING
(TYP.)
B E
N C
H
B E
N C
H
CONC.
C O
N C
H V
A C
H V
A C
HVAC
HVAC
C
O
N
C
W
A
L
K
C
O
N
L
K
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG/E UG/E UG/E UG/E UG/E
UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/EFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E TC=252.03
GRT=251.38
INV=244.2
CB
UG/E
UG/E
UG/E
UG/E
TC=239.05
GRT=238.56
INV=235.9
CB
12" STEEL
12" RCP
(C)
(A)
(A)
(B)
12" CLAY
5 STORY1 STORY5 STORY
1 STORY
3 STORY1 STORY
B
L
O
L
L
W A
L L
VALVE
SOUTH CENTER STREET
(ASPHALT ROADWAY)
(TWO WAY TRAFFIC)
4 2
UG/E
UG/E
PORTION OF EXISTING BLOCK WALL TO BE REMOVED. CONTRACTOR TO
MINIMIZE EXCAVATION ASSOCIATED WITH REMOVAL OF WALL AND NOT
DAMAGE EXISTING DUCT BANK RUNNING UNDERNEATH WALL
EXISTING UNDERGROUND
ELECTRICAL DUCT BANK TO REMAIN
PORTION OF EXISTING CIP RETAINING
WALL WITH FENCE TO BE REMOVED
EXISTING FENCE AND POLES TO
BE REMOVED AND REPLACED
EXISTING ELECTRICAL EQUIPMENT
(TO REMAIN)
EXISTING ELECTRICAL EQUIPMENT
(TO REMAIN)
EXISTING GATES TO BE
REMOVED AND REPLACED
VAULT A
DEMO EXISTING FENCE
(REFERENCE STRUCTURAL PLANS
FOR DETAILS)
CONCRETE PAD
EL.= 236.50' CONCRETE PAD
EL.= 238.50'
EX. ELECTRIC MH
RIM= 236.18
EX. ELECTRIC MH
RIM = 253.46
INVERT= 235.26
EXISTING GATE
(TO BE REMOVED)
FIRST SEGMENT OF BLOCK TO REMAIN WHERE
STACKED 3 BLOCKS HIGH
CONTRACTOR TO REMAIN A MINIMUM OF 5'
OFF EXISTING WALL WITH CONSTRUCTION
AND MINIMIZE EXCAVATION IN AREAS
ADJACENT TO EXISTING BLOCK WALL
EXISTING GATE
(TO BE REMOVED)
EXISTING BLOCK WALL
TO REMAIN. CONTRACTOR TO DETERMINE EMBEDMENT
DEPTH OF EXISTING WALL AND HAVE A LICENSED
ENGINEER CERTIFY THE PROPOSED DESIGN WILL NOT
NEGATIVELY IMPACT THE EXISTING STONE WALL.
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
321 4 5 6 7
A B
C D
E
Dwg. of
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
CONSULTANTS:
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date#
1, 2, 5, 7
02/05/2020
IMPROVE ELECTRICAL
DEFICIENCIES, II A & B
561-18-135
VA NJ HEALTH CARE SYSTEM
385 TREMONT AVENUE
EAST ORANGE, NJ 07018
X
18-096
ISSUED FOR CONSTRUCTION
FULLY SPRINKLERED
Foresite Group, Inc.
2128 Moores Mill Rd.
Suite C Auburn, AL 36830 o | 334.887.6064 f | 334.887.6024 w | www.fg-inc.net
DEMOLITION PLAN LEGEND
RETAINING WALL TO BE REMOVED
FENCE TO BE REMOVED AND REPLACED
PROPERTY LINE
LIMITS OF DISTURBANCE
LOD LOD LOD
GENERAL NOTES:
1. CONTRACTOR TO PROVIDE TEMPORARY FENCING IN THE FORM
OF A 6' HIGH GALVANIZED CHAIN LINK FENCE AROUND THE
PROPOSED IMPROVEMENTS.
2. ALL NEW WORK SHOWN IN THESE SHEETS SHALL COMPLY WITH
APPLICABLE STATE, FEDERAL, AND LOCAL BUILDING AND UTILITY
INSTALLATION CODES.
3. ALL MATERIALS AND CONSTRUCTION METHODS SHALL BE IN
ACCORDANCE WITH DEPARTMENT OF VETERAN AFFAIRS
TECHNICAL INFORMATION LIBRARY STANDARD SPECIFICATIONS.
4. THERE MAY BE ADDITIONAL UTILITIES NOT SHOWN ON THESE
PLANS. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR
LOCATIONS SHOWN, AND IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO FIELD VERIFY THE LOCATIONS OF ALL UTILITIES
WITHIN THE LIMITS OF CONSTRUCTION AND TO NOTIFY THE OWNER
IN CASE OF DISCREPANCIES THAT AFFECT THE CONSTRUCTION
PROJECT.
5. THE CONTRACTOR IS RESPONSIBLE FOR NOTIFICATION OF AND
LIAISON WITH VETERAN AFFAIRS IN THE PROCESS OF LOCATION
AND RELOCATION OF AND TIE-IN TO VETERAN AFFAIRS' UTILITIES.
6. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE THAT MAY
OCCUR TO ANY ADJACENT STRUCTURES OR PROPERTY, OR ANY
EXISTING STRUCTURES WITHIN LIMITS OF CONSTRUCTION THAT
ARE DESIGNATED ON THE PLANS TO REMAIN, AND SHALL REPAIR
OR REPLACE SUCH DAMAGED PROPERTY TO THE VETERAN
AFFAIRS' SATISFACTION AT NO COST TO THE VETERAN AFFAIRS.
7. THE CONTRACTOR SHALL NOT DEVIATE FROM THESE PLANS
AND SPECIFICATIONS WITHOUT THE PRIOR WRITTEN CONSENT OF
THE ENGINEER AND/OR COR.
8. CONTRACTOR IS RESPONSIBLE FOR CONTACTING
DEPARTMENT OF VETERAN AFFAIRS AND ALL EXISTING UTILITY
PROVIDERS BEFORE REMOVING ANY/ALL UTILITIES FROM THEIR
EXISTING LOCATION ON THE SITE. THE CONTRACTOR SHALL
PERFORM ALL UTILITY DEMOLITION OR RELOCATION ACTIVITIES IN
ACCORDANCE WITH THE EXISTING UTILITIES SPECIFICATIONS,
MATERIALS, AND REQUIREMENTS.
9. THE CONTRACTOR SHALL SEQUENCE THE WORK AND PROVIDE
TEMPORARY MEASURES AS NECESSARY TO MAINTAIN ACCESS TO
THE SITE THROUGH ALL ENTRANCES AT ALL TIMES DURING
CONSTRUCTION. TEMPORARY PROVISIONS MAY INCLUDE, BUT ARE
NOT LIMITED TO: BARRICADES, FLASHING LIGHTS, FLAGMAN,
TEMPORARY PAVEMENT, AND DIRECTIONAL SIGNAGE AS
NECESSARY TO ACCOMPLISH THE WORK.
10. CONTRACTOR SHALL CONSIDER COORDINATION ASPECTS OF
CRANES AND CONSTRUCTION EQUIPMENT OPERATIONS DURING
DEMOLITION ACTIVITY.
11. COORDINATE WITH DEPARTMENT OF VETERAN AFFAIRS CODES
ENFORCEMENT DIVISION AS REQUIRED DURING ALL DEMOLITION
AND NEW CONSTRUCTION ACTIVITIES.
12. ALL ITEMS DESIGNATED FOR REMOVAL SHALL BE LEGALLY
DISPOSED OF OFF SITE.
13. CONTRACTOR TO POT HOLE EXISTING WATER LINE,
UNDERGROUND ELECTRICAL LINES, GAS LINE, UNDERGROUND
TELEPHONE, FIBER OPTIC, AND ANY OTHER UTILITY LINES DURING
DEMOLITION ACTIVITIES AND COORDINATE FIELD LOCATIONS AND
DEPTHS OF THESE UTILITIES WITH ENGINEER FOR PROPOSED
UTILITY CROSSINGS AND PROPOSED PAVEMENT OVER EXISTING
LINES. THESE LINES MAY REQUIRE RELOCATION. IMMEDIATELY
NOTIFY COR IF THERE ARE ANY DISCREPANCIES OR CONFLICTS
WITH THE DRAWINGS.
14. THE CONTRACTOR SHALL PROVIDE DUST CONTROL AND SHALL
PROTECT ADJACENT PAVEMENTS FROM SOIL ACCUMULATION
DURING CONSTRUCTION.
15. ADDITIONAL EROSION CONTROL DEVICES MAY BE REQUIRED
BY THE ENGINEER OR OTHER INSPECTORS AS DETERMINED BY
FIELD CONDITIONS.
16. STORM DRAINAGE STRUCTURES AND CONDUITS SHALL BE
PROTECTED FROM SEDIMENTATION AS REQUIRED BY STATE OR
LOCAL CODES.
1" = 20'
SCALE IN FEET
20 10 20 40
DocuSign Envelope ID: CA86D127-DB02-414A-9C7B-04E0EE29525A
2/4/2020
UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E
UG/E
UG/E
UG/E
UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E UG/E UG/E UG/E UG/E
UG/E
UG/E
UG
/E
UG
/E
UG/E
UG/E
UG/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG
/E
UG/E
UG/E UG/E UG/E UG/E UG/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG/E
UG/E
UG/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
D.C.
D
C
D
C
CONC. CURB
C
O N
C . C
U R
B
D
C
D.C.
D
.C
C O
N C
. C U
R B
CONC. CURB
C
O
N
R
B
C
O
N
C
C
U
R
B
C
O
N
R
B
C
O
N
R
B
C
O
N
C
C
U
R
B
CONC.
CURB
CONC.
CURB
CONC.
CURB
STEPS
W/HANDRAIL
CONC. STEPS
CONC. WALL W/8' HIGH C.L.F.
BRICK WALL
BRICK WALL
S T
O N
E
W
A L L
BRICK WALL
CONC. WALL
CONC. WALL
HANDRAIL
10' HIGH C.L.F.
10' HIGH C.L.F.
8' HIGH IRON FENCE
8' HIGH IRON FENCE
STONE WALL
STONE WALL
C O
N C
. W A
L L
HANDRAIL
H
A
N
D
R
A
I
L
H A
N D
R A
I L
M
G
R
S T
O N
E W
A L L
M
G
R
M
G
R
H
I G
H
L
F
O
B
O
L
L
FLAG POLE
(TYP.)
6' HIGH C.L.F.
E
O
P
E
O
P
CONC.
E.O.P.
E.O.P.
E
O
P
C O
N C
W
A L K
CONC. WALK
CONC. WALK
CONC. RAMP
CONC. WALK
C
O
N
L
K
C
O
N
C
W
A
L
K
CONC.
CONC. WALK
CONC.
S
W
L
S.Y.L.
S W
L
S
R
L
C
R
O
S
S
W
A
L
K
YELLOW
STRIPING
S
Y
L
S
W
L
S
R
L
UG/E
UG/E
UG/E
UG/E
FOC
FOC
FOC
FOC
FOC
FO
C
FO
C
FO
C
W W
W W
W W
W
RIM=246.56
INV(A)=235.7
INV(B)=235.6
DMH
DMH
RIM=249.46
INV(A)=239.2
INV(B)=239.1 W W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
DMH
RIM=252.27
INV(A)=248.4
INV(B)=241.4
DMH
RIM=243.73
INV(A)=238.6
INV(B)=236.9
GRT=242.02
INV(A)=238.6
INV(B)=237.1
INV(C)=237.0
INV(D)=236.6
INV(E)=235.2
INV(F)=234.8
CB
DMH
RIM=256.36
INV(A)=251.9
INV(B)=248.7
NV(C)=248.5
INV(D)=242.1
FO
C
FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC
FOC
FOC FOC FOC
FO
C
FO
C
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GA
S
GA
S
GA
S
GRT=253.53
INV=250.7
CB
GRT=250.40
INV=247.2
CB
DMH
RIM=250.48
INV(A)=244.3
INV(B)=243.9
INV(C)=243.8
INV(D)=239.4
FOC FOC FOC FOC FOC
FOC
FOC
FOC
RIM=252.52
TC=251.13
GRT=250.45
INV=243.9
CB
TC=251.64
GRT=251.01
INV=244.7
CB
GRT=241.79
CB
GRT=246.76
BOS=243.8±
(FWD)
(NPV)
CB
FOC
FOC
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
INV=232.27
FES
INV=232.26
FES
RIM=251.04
DMH
RIM=254.15
INV(A)=249.5
INV(B)=247.8
15" S
TEEL
E
E
L
E
E
L
(D)
(A)
(B)
(C)
6" STEEL
(A)
E
E
L
S
T
E
E
L
E
E
L
S
T
E
E
L
R
C
P
(A)
(B)
12" STEEL
(A)
(B)
C
12" STEEL
C
6" PVC
6" PVC
(A)
(B)
(D)
(E)
(F)
(A)
(B) (B)
(A)
(C)
(B)
(D)
FDC
FDC
"DO NOT ENTER"
"WRONG WAY"
"DO NOT ENTER"
"WRONG WAY"
"NO PARKING
FIRE LANE"
"TOW AWAY ZONE"
"NO PARKING
FIRE LANE"
"TOW AWAY ZONE"
"STOP"
"ONE WAY"
"SPEED LIMIT 5"
"STEVEN GREGG DRIVE"
"URESKO DRIVE"
"ONE WAY"
"NO LEFT TURN"
"ONE WAY
DO NOT ENTER"
"WRONG WAY"
"CAMERA"
"ONE WAY"
"AMBULANCE PARKING
ONLY"
"NO PARKING
FIRE LANE"
"DO NOT ENTER"
"WRONG WAY"
CONC. RAMP
W/HANDRAIL
C
O
N
C
R
A M
P
ASPHALT
PAVEMENT
ASPHALT
PAVEMENT
ASPHALT
PAVEMENT
ASPHALT
PAVEMENT
E
O
C
TMH
TMH
6" STEEL
(B)
(B)
RIM=254.92
TMH
CONC.
WALK
POW
POW
HANDRAIL
G R
A N
I T
E
W
A L L
G R
A N
I T
E
W
A L L
6" PVC STORM DRAIN
(SEE NOTE 3)
S W
L
S W
L
C
O
N
C
R
A M
P
H A
N D
R A
IL
H A
N D
R A
IL
CONC.
E .O
.P
ASPHALT
PAVEMENT
CONC. WALL
E.O.C.
YELLOW STRIPING
(TYP.)
CONC.
C O
N C
H V
A C
H V
A C
HVAC
HVAC
C
O
N
C
W
A
L
K
C
O
N
L
K
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG
/E
UG/E UG/E UG/E UG/E UG/E
UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/EFOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E TC=252.03
GRT=251.38
INV=244.2
CB
UG/E
UG/E
UG/E
UG/E
TC=239.05
GRT=238.56
INV=235.9
CB
12" STEEL
12" RCP
(C)
(A)
(A)
(B)
12" CLAY
W A
L L
VALVE
SOUTH CENTER STREET
(ASPHALT ROADWAY)
(TWO WAY TRAFFIC)
4 2
UG
/E
UG/E
UG/E
UG
/E
UG
/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E
UG/E UG/E UG/E UG/E UG/E UG/E UG/E
UG/E UG/E UG/E UG/E
UG/E
UG/E
UG/E
UG
/E
UG
/E
UG/E
UG/E
PROPOSED TRANSFORMER
(SEE ELECTRICAL PLANS FOR DETAILS)
PROPOSED SLAB ON GRADE
CONCRETE PAD FOR SWITCH
GEAR BUILDING (SEE 1/CS 505
FOR DETAILS)
PROPOSED ELECTRICAL SWITCH GEAR BUILDING
(SEE ELECTRICAL PLANS FOR DETAILS)
PROPOSED UNDERGROUND
ELECTRIC MANHOLE
PROPOSED UNDERGROUND ELECTRICAL DUCT BANKS
(SEE ELECTRICAL PLANS FOR DETAILS, TYP.)
PORTION OF EXISTING UNDERGROUND
ELECTRICAL TO REMAIN UNDERNEATH BUILDING
USE DUCT BANK BRIDGE IF NECESSARY
(SEE 2 AND 6/ CS 505 FOR DETAILS)
15.5'
VAULT A
PROPOSED 6' BLACK VINYL COATED
CHAIN LINK FENCE
(SEE STRUCTURAL PLANS FOR DETAILS)
PROPOSED SINGLE GATE
(SEE STRUCTURAL PLANS FOR DETAILS)
PROPOSED 10' FENCE WITH BARBED
WIRE TO MATCH EXISTING
(SEE 3/CS 505 FOR DETAIL)
PROPOSED 10' FENCE TO
MATCH EXISTING
(SEE 4/CS 505 FOR DETAIL)
CONCRETE PAD
EL.= 238.50'
PROPOSED FENCE TO ATTACH TO WEST CORNERS
OF PROPOSED SWITCH GEAR BUILDING
PROPOSED STONE WALL
TO MATCH EXISTING. CONTRACTOR TO DETERMINE
EMBEDMENT DEPTH OF EXISTING STONE WALL AND
HAVE A LICENSED ENGINEER CERTIFY THE
PROPOSED DESIGN WILL NOT NEGATIVELY IMPACT
THE EXISTING STONE WALL.
PROPOSED SWING GATE WITH
BARBED WIRE TO MATCH EXISTING
(SEE 7/CS 505 FOR DETAIL)
PROPOSED TYPE "B" BOLLARD
(SEE 8/CS 505 FOR DETAILS)
237.00
236.50
237.00
237.50
237.41
237.31
238.98 TW
237.50 BW
240.00 TW
237.00 BW
236.50
239.00 TW
236.17 BW
236.00
236.00
237.40
236.72
236.92
236.92
236.88
239.23 TW
237.50 BW
236.50
235.92
235.92
CONCRETE
PAD EL =
237.50
PROPOSED CONDUIT TO BE ROUTED UNDERNEATH
EXISTING CIP WALL. CONTRACTOR TO VERIFY FOOTING
DEPTHS OF EXISTING WALL AND COORDINATE WITH
ENGINEER PRIOR TO CONSTRUCTION
PROPOSED FENCE TO
ATTACH TO SOUTHEAST
CORNER OF PROPOSED
SWITCH GEAR BUILDING
PROPOSED FENCE TO ATTACH TO FACE OF WALL
(SEE 9/CS 505 FOR DETAIL)
PROPOSED SWING GATE TO
MATCH EXISTING
(SEE 5/CS 505 FOR DETAIL)
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
321 4 5 6 7
A B
C D
E
Dwg. of
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
CONSULTANTS:
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date#
1, 2, 5, 7
02/05/2020
IMPROVE ELECTRICAL
DEFICIENCIES, II A & B
561-18-135
VA NJ HEALTH CARE SYSTEM
385 TREMONT AVENUE
EAST ORANGE, NJ 07018
X
18-096
ISSUED FOR CONSTRUCTION
FULLY SPRINKLERED
Foresite Group, Inc.
2128 Moores Mill Rd.
Suite C Auburn, AL 36830 o | 334.887.6064 f | 334.887.6024 w | www.fg-inc.net
GRADING AND DRAINAGE PLAN LEGEND
EXISTING CONTOURS
PROPOSED CONTOURS
EXISTING SPOT ELEVATION
PROPOSED SPOT ELEVATION
PROPOSED TOP OF CURB / BOTTOM OF CURB
SPOT ELEVATION
TC
BC
XXXX.XX
XXXX.XX
XXXX.XX
XXXX.XX
XXXX
XXXX
SITE AND PAVING PLAN LEGEND
PROPOSED CONCRETE PAVING
PROPOSED LANDSCAPING
PROPERTY LINE
GENERAL NOTES:
1) ALL PROPOSED DIMENSIONS USED TO SHOW THE GEOMETRIC
LAYOUT OF THE PROPOSED PARKING LOT ARE SHOWN AT THE FACE
OF CURB. ALL PROPOSED DIMENSIONS USED TO SHOW THE
GEOMETRIC LAYOUT OF THE PROPOSED BUILDING LOCATION ARE
GIVEN AT THE OUTSIDE FACE OF THE BUILDING CORNERS. ALL
CURB RADII ARE GIVEN AT THE FACE OF CURB.
2) CONTRACTOR SHALL NOTIFY THE COR OF ANY DISCREPANCIES
BETWEEN THE EXISTING CONDITIONS IN THE FIELD AND THE
SURVEY SHOWN ON THE PLANS BEFORE PROCEEDING WITH ANY
NEW CONSTRUCTION.
3) CONTRACTOR IS RESPONSIBLE FOR CORRECT HORIZONTAL
AND VERTICAL ALIGNMENT OF ALL TIES BETWEEN PROPOSED AND
EXISTING PAVEMENTS, CURB AND GUTTER, SIDEWALKS, WALLS,
AND UTILITIES.
4) MAXIMUM CUT OR FILL SLOPE= 2H:1V.
GENERAL NOTES:
1) ALL SPOT ELEVATIONS SHOWN ARE AT THE EDGE OF
PAVEMENT UNLESS OTHERWISE NOTED.
SITE NOTES:
1) THE CONTRACTOR SHALL CLEAN OUT ACCUMULATED SILT IN
STORM WATER CONVEYANCE CHANNELS AND PIPES AT END OF
CONSTRUCTION AFTER DISTURBED AREAS HAVE BEEN STABILIZED.
2) IN ALL AREAS OF FILL OR OTHERWISE DISTURBANCE OF
EXISTING CONDITIONS, UNLESS OTHERWISE NOTED, THE
CONTRACTOR SHALL FULLY AND COMPLETELY REMOVE AND
LEGALLY DISPOSE OFF-SITE, ALL PLANT MATERIALS INCLUDING BUT
NOT LIMITED TO ROOT SYSTEMS, CONCRETE, REINFORCED
CONCRETE, ASPHALT DEBRIS, UNDERBRUSH, TOPSOIL, AND OTHER
DELETERIOUS MATERIAL. THE SUBGRADE TO REMAIN SHALL BE
COMPACTED TO 95% STANDARD PROCTOR MAXIMUM DRY DENSITY
FOLLOWING FULL REMOVAL OF THESE MATERIALS.
3) IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN
QUALIFIED PROFESSIONAL ADVICE WHEN QUESTIONS ARISE
CONCERNING DESIGN AND EFFECTIVENESS OF EROSION CONTROL
DEVICES. 24 HR. CONTACT: SHANE YARBROUGH (334) 887-6064
4) EXTREME CAUTION SHALL BE USED WHEN WORKING WITHIN
THE VICINITY OF THE EXISTING OVERHEAD POWER LINES.
CONTRACTOR SHALL NOTIFY/COORDINATE WITH COR PRIOR TO
CONSTRUCTION.
LEGEND
EXISTING FENCE LINE
PROPOSED FENCE LINE
PROPOSED BARBED WIRE FENCE LINE
PROPERTY LINE
EXISTING OVERHEAD POWER LINE
EXISTING UNDERGROUND POWER LINE
EXISTING UNDERGROUND TELEPHONE LINE
EXISTING GAS LINE
EXISTING SANITARY SEWER LINE
EXISTING WATER LINE
EXISTING STORM LINE
EXISTING UNKNOWN UTILITY LINE
PROPOSED UNDERGROUND POWER LINEUG/E UG/E
W W W
SS SS SS
GAS GAS GAS
UG/T UG/T
UG/E UG/E
OHP OHP OHP
1" = 20'
SCALE IN FEET
20 10 20 40
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
321 4 5 6 7
A B
C D
E
Dwg. of
Office of
Construction and Facilities
Management
PROJECT MANAGER:
ACG Project Number
CONSULTANTS:
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120
Cary, North Carolina 27511 www.acg-pa.com 919-858-7420
NC License #: C-1848
U.S. Department of Veterans Affairs
© COPYRIGHT Apogee Consulting Group, P.A.Revisions: Date#
1, 2, 5, 7
02/05/2020
IMPROVE ELECTRICAL
DEFICIENCIES, II A & B
561-18-135
VA NJ HEALTH CARE SYSTEM
385 TREMONT AVENUE
EAST ORANGE, NJ 07018
X
18-096
ISSUED FOR CONSTRUCTION
FULLY SPRINKLERED
Foresite Group, Inc.
2128 Moores Mill Rd.
Suite C Auburn, AL 36830 o | 334.887.6064 f | 334.887.6024 w | www.fg-inc.net
TYPICAL GRADE SUPPORTED SLAB AT CONCRETE PAD
NOT TO SCALECS 505
DUCT BANK BRIDGE
NOT TO SCALECS 505
I
M
X
I N
M A
X
C
H A
I
N
K
H E
I G
H T
I N
8 IN.
10 FT - 0 IN C/L TO C/L MAX.
NOT TO SCALE
10' HIGH CHAINLINK FENCE
CS 505
12"
12"
12"
10'-0" MAX.10'-0" MAX. AS SPECIFIED AS SPECIFIED
T
Y P
GATEGATE
TRUSS ROD
(TYP.)
PLUNGER
BAR CATCH
GALVANIZED PIPE
CLASS "B" CONCRETE 3,000 PSI
REQUIRED AT CORNET AND GATE POSTS
(TYP.)
3/8" NOMINAL SIZE
ADJUSTED BASE ROD
(REQUIRED AT CORNER
AND GATE POSTS)
FINISH GRADE
PLUNGER BAR
STRETCHER BAR
END OR PULL PANEL
LINE PANEL
POST BRACE
(REQUIRED ON EITHER SIDE
OF CORNER AND GATE POST)
NOTE:
1.) ALL FENCING SHALL BE GALVANIZED. .
11 GA. 2", BLACK VINYL COATED
WIRE FABRIC (TYP.)
KNUCKLED
SELVAGES (TYP.)
KNUCKLED
SELVAGES
(TYP.)
TRUSS ROD
(TYP.)
7 GA. TENSIONING WIRE
10' CHAIN LINK FENCE (WITH SWING GATE)
NOT TO SCALE
CS 505
2" LINE POSTS
M
I N
F O
R
I N
T E
R M
E D
I A
T E
P O
S T
S
2.375" CORNER AND MAIN GATE
POST. 4" EQUIPMENT GATE POST
1-5/8" TOP RAIL
I
M
X
I N
M A
X
C
H A
N
K
H E
I G
H T
I N
8 IN.
10 FT - 0 IN C/L TO C/L MAX.
NOT TO SCALE
10' HIGH CHAINLINK FENCE WITH BARBED WIRE
CS 505
12"
12"
12"
10'-0" MAX.10'-0" MAX. AS SPECIFIED AS SPECIFIED
T
Y P
GATEGATE
TRUSS ROD
(TYP.)
PLUNGER
BAR CATCH
GALVANIZED PIPE
CLASS "B" CONCRETE 3,000 PSI
REQUIRED AT CORNET AND GATE POSTS
(TYP.)
3/8" NOMINAL SIZE
ADJUSTED BASE ROD
(REQUIRED AT CORNER
AND GATE POSTS)
FINISH GRADE
PLUNGER BAR
STRETCHER BAR
END OR PULL PANEL
LINE PANEL
POST BRACE
(REQUIRED ON EITHER SIDE
OF CORNER AND GATE POST)
NOTE:
1.) ALL FENCING SHALL BE GALVANIZED. .
11 GA. 2", BLACK VINYL COATED
WIRE FABRIC (TYP.)
KNUCKLED
SELVAGES (TYP.)
KNUCKLED
SELVAGES
(TYP.)
TRUSS ROD
(TYP.)
7 GA. TENSIONING WIRE
10' CHAIN LINK FENCE WITH BARBED WIRE (WITH SWING GATE)
NOT TO SCALECS 505
2" LINE POSTS
M
I N
F O
R
I N
T E
R M
E D
I A
T E
P O
S T
S
2.375" CORNER AND MAIN GATE
POST. 4" EQUIPMENT GATE POST
1-5/8" TOP RAIL
M
I N
8"
3/4" CHAMFER
#5@12"
#5@12"
1#5 CONT #5 @ 12" O.C. E.W.
T&B
#5 @ 12" O.C. E.W.
T&B
6" COMPACTED
GRANULAR FILL
6'-0" ±
8"
36x24 DUCT BANK
#5@12"
F I E
D
E R
I F
Y
#5 @ 12" O.C. E.W.
#5 @ 12" O.C.
TURNDOWN
SLAB
NOT TO SCALE
DUCT BANK BRIDGE WITH TURNDOWN CONFLICT
CS 505
CONCRETE POST BARRICADES
NOT TO SCALE
CS 505
" EXPANSION
ANCHOR
W/ 2
" EMBED
PL9x9x
FENCE POST
M I N
TOP OF WALL
M I N
PL9x9x
" EXPANSION
ANCHOR
W/ 2
" EMBED
FENCE POST
(E) WALL
NOT TO SCALE
FENCE POST WALL ATTACHMENT DETAIL
CS 505
9"
6"
| Sheets and Views |
| CD-101 DEMOLITION PLAN |
| C-502 SITE, PAVING, AND UTILITY PLAN |
| CS 505 CONSTRUCTION DETAILS |
File details come from the government source that posted it. Updated .