36C24219B0016-003.pdf
PDF 9 MB Posted
- Attached to
- 561A4-12-150 Repair Brick Façade B-135
- Solicitation number
- 36C24219B0016
About this file
36C24219B0016 100_Drawings-R.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24219C0134-000.docx | DOCX document | |
| 36C24219B0016-0002001.pdf | ||
| 36C24219B0016-0002000.docx | DOCX document | |
| 36C24219B0016-0001001.pdf | ||
| 36C24219B0016-0001002.pdf | ||
| 36C24219B0016-0001000.docx | DOCX document | |
| 36C24219B0016-001.docx | DOCX document | |
| 36C24219B0016-002.pdf | ||
| 36C24219B0016-004.pdf | ||
| 36C24219B0016-000.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AA/COS
CHIEF ENGINEERING
CHIEF ENVIRONMENTAL
ENGINEERING
TECHNICIAN
OPERATIONS
SUPERVISOR
MAINTENANCE
SUPERVISOR
BUILDING/GROUNDS
SUPERVISOR
QUALITY MANAGEMENT
IC RN-PPCI
SAFETY OFFICER
PATIENT SAFETY PPCI
CHIEF VA POLICE
IT/TELECOM
JOB TITLE SIGNATURES
APPROVAL SIGNATURES
Department of Veterans Affairs
Drawing Title Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Office of Construction and Facilities Management
CONSULTANTS:
Approved: Project Director
REPAIR BRICK FACADE
B-135
VA LYONS CAMPUS, VA NEW JERSEY
561A4-06-150
TJW GSE06/18/2018
BUILDING 135
612 NW Kay Drive | Lee's Summit | Missouri | 64063
(816) 525-9833 | (816) 472-5656 | tjw@tom-arch.com
SEAL:ARCHITECT/ENGINEER OF RECORD:
65% DESIGN SUBMISSION 08/25/2017
WATSON ENGINEERING, PC
1112 STATE ROUTE 434
OWEGO, NY 13827
(607) 223-4334
CMG
10727 W 128 ST
OVERLAND PARK, KS 66213
(913) 239-8900 G001
COVER SHEET
REPAIR BRICK FACADE B-135
VA NEW JERSEY HEALTH CARE SYSTEM
LYONS, NEW JERSEY
VICINITY MAP KEY MAP
B-135
B-135
DRAWING SHEET INDEX
SHEET # SHEET TITLE
G001 COVER SHEET
G002 GENERAL INFORMATION
C100 SCAFFOLDING ELEVATION DRAWINGS
S100 SECTION DETAILS
AE101 ROOF PLAN
AE151 ENLARGED PLANS & ELEVATIONS
AE201 EAST ELEVATION
AE202 NORTH ELEVATION
AE203 WEST ELEVATIONS
AE204 SOUTH ELEVATIONS
AE205 EAST/WEST ELEVATIONS
AE206 COURTYARD ELEVATIONS
AE500 DETAILS
N N
2018.12.18
561A4-12-150
REPLACE CAST STONE JOINTS AT BUILDING EXTERIOR
- Remove existing sealant / caulk, backer rod and grout around all exterior capstone joints
- Clean dirt and debris from inside joints
- Replace sealant / caulk, backer rod and grout around all exterior capstone joints
REPLACE JOINTS AT EXTERIOR WINDOWS
- Remove existing sealant / caulk around all exterior windows and cast stone sills
- Clean dirt and debris from inside joints
- Replace sealant / caulk around all exterior windows and cast stone sills
- Clean cast stone sills
- Clean windows from any dirt or debris from construction
REPAIR BRICK AT BUILDING EXTERIOR
- Remove brick courses at parapet (courses from capstone to parapet flashing, APPROX. 12 courses)
- Clean out any grout and mortar.
- Install proper flashing
- Install brick with weep holes every 2'-0" O.C.
- Ref: 4/AE500
REPAIR PORTION OF ENTRY CANOPY ROOF
- Remove existing roof membrane and insulation
- Install new tapered insulation to existing roof drains.
- Install new roof membrane
- Ref: AE500 for details
- NOTE: Entrance must remain open at all times. Reference Civil drawings for scaffolding layout.
REPLACE JOINTS AT CLERESTORY WINDOWS
- Remove existing sealant / caulk around exterior clerestory windows
- Clean dirt and debris from inside joints
- Replace sealant / caulk around all exterior windows
- Clean windows from any dirt or debris from construction
CORRECT LEANING PARAPET WALL
- Install #4 bar in core of 8" and 4" CMU blocks
- See ROOF PLAN for location
- See sheet S100 for details
CLEAN CAPSTONE AT BUILDING EXTERIOR
- Remove lime run and efflorescence from face of brick
- Replace sealant / caulk, backer rod and grout at joints as required
CLEAN BRICK FACADE
- Remove lime run and efflorescence from face of brick
- Repair or replace cracked and damaged brick
- Tuck point areas with mortar failure
BASE BID ITEMS
SCOPE OF WORK SUMMARY
(A)
(B)
(C)
(D)
(E)
(F)
(G)
(H)
A
B
D
H
C
H
B
E
A
B
F
H
A
C
E
B
EXAMPLE PHOTOGRAPHS
H
Department of Veterans Affairs
Drawing Title Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Office of Construction and Facilities Management
CONSULTANTS:
Approved: Project Director
REPAIR BRICK FACADE
B-135
VA LYONS CAMPUS, VA NEW JERSEY
561A4-06-150
TJW GSE06/18/2018
BUILDING 135
612 NW Kay Drive | Lee's Summit | Missouri | 64063
(816) 525-9833 | (816) 472-5656 | tjw@tom-arch.com
SEAL:ARCHITECT/ENGINEER OF RECORD:
65% DESIGN SUBMISSION 08/25/2017
WATSON ENGINEERING, PC
1112 STATE ROUTE 434
OWEGO, NY 13827
(607) 223-4334
CMG
10727 W 128 ST
OVERLAND PARK, KS 66213
(913) 239-8900 G002
GENERAL INFORMATION
Department of
Veterans
Affairs
Drawing Title Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. of
Revisions: Date
1 2 3 4 5 6 87 9
97 8654321
Office of
Construction and Facilities
Management
CONSULTANTS:
Approved: Project Director
REPAIR BRICK FACADE
B-135
VA LYONS CAMPUS, VA NEW JERSEY
561A4-06-150
AJS GSE06/18/2018
BUILDING 135
P
R
E
L
I
M
I
N
A
R
Y
N
O
T
F
R
C
O
N
S
T
R
U
C
T
I
O
N
612 NW Kay Drive | Lee's Summit | Missouri | 64063
(816) 525-9833 | (816) 472-5656 | ajs@tom-arch.com
SEAL:
ARCHITECT/ENGINEER OF RECORD:
100% DESIGN SUBMISSION 06/18/2018
WATSON ENGINEERING, PC
1112 STATE ROUTE 434
OWEGO, NY 13827
(607) 223-4334
CMG
10727 W 128 ST
OVERLAND PARK, KS 66213
(913) 239-8900
NOTES:
1. PROPOSED SCAFFOLDING STAIRCASE TO BE COMPLETE WITH
RAILING WHICH IS NOT SHOWN FOR CLARITY.
2. PROPOSED TOP WORKING PLATFORM TO BE COMPLETED WITH
TOE BOARDS AND GUARD RAILS, WHICH ARE NOT SHOWN FOR
CLARITY.
3. PROPOSED ANCHOR SCREWS TO BE INSTALLED INTO BRICK
JOINT.
4. ANCHOR HOLE TO BE SEALED WITH CAULKING UPON REMOVAL
OF SCAFFOLDING.
SCALE: 3/16" = 1'-0"
PROPOSED SCAFFOLDING AREA PLAN VIEW
F1
EXISTING ENTRYWAY OVERHANG
EXISTING TRAFFIC CIRCLE
SCALE: 3/16" = 1'-0"
PROPOSED SCAFFOLDING AREA ELEVATION VIEW
C1
21'
8'
18'
ENTRYWAY INTO BUILDING 135
WALL AREAS TO BE REPAIRED OVER GLASS ROOF TO ENTRYWAY.
GLASS TO BE PROTECTED BEFORE ANY WORK IS COMPLETED.
SCAFFOLDING TO ANCHOR TO WALLS OR UP AND OVER GLASS
ANGLED ROOF TO MAIN ROOF.
GLASS ROOF OF ENTRYWAY
ANGLED GLASS ROOF BELOW SCAFFOLDING,
TO BE PROTECTED DURING WORK
C100
SCAFFOLDING
ELEVATION DRAWINGS
1'
25' W8X6.2 ALUMINUM BEAMS TO COVER 8' OF
THE SKYLIGHT
18' W8X6.2 ALUMINUM BEAM TO ENSURE THE
LONGITUDINAL BEAMS DO NOT SLIP
2" ISO FOAM INSULATION
PLASTIC TARP TO PREVENT
MOISTURE FROM INSULATION
" CDX EXTERIOR PLYWOOD
MECHANICALLY FASTENED TO
ALUMINUM BEAMS
W8X6.2 ALUMINUM BEAMS
W8X18 ALUMINUM BEAM TO ENSURE
LONGITUDINAL BEAMS DO NOT SLIP
WATER PROOF BEAM ENDS
1'
5'
Department of
Veterans
Affairs
Drawing Title Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. of
Revisions: Date
1 2 3 4 5 6 87 9
97 8654321
Office of
Construction and Facilities
Management
CONSULTANTS:
Approved: Project Director
REPAIR BRICK FACADE
B-135
VA LYONS CAMPUS, VA NEW JERSEY
561A4-06-150
AJS GSE06/18/2018
BUILDING 135
P
R
E
L
I
M
I
N
A
R
Y
N
T
F
R
C
O
N
S
T
R
U
C
T
I
O
N
612 NW Kay Drive | Lee's Summit | Missouri | 64063
(816) 525-9833 | (816) 472-5656 | ajs@tom-arch.com
SEAL:
ARCHITECT/ENGINEER OF RECORD:
100% DESIGN SUBMISSION 06/18/2018
WATSON ENGINEERING, PC
1112 STATE ROUTE 434
OWEGO, NY 13827
(607) 223-4334
CMG
10727 W 128 ST
OVERLAND PARK, KS 66213
(913) 239-8900
SCALE: 1-1/2" = 1'-0"
EXISTING PARAPET WALL SECTION VIEW DETAIL
F1
CAPSTONE
BRICK FACADE TO BE REPAIRED
8" CMU BLOCK
ROOF MEMBRANE RUNS UP WALL
AND UNDER COPING STONE
4" CMU BLOCK
RIGID ROOF INSULATION
TYPICAL BEAM
BUILDING
INTERIOR
SCALE: 1-1/2" = 1'-0"
PROPOSED PARAPET WALL SECTION VIEW DETAIL
F4
NEW BRICK FACADE
8" CMU BLOCK
ROOF MEMBRANE RUNS UP WALL
AND UNDER COPING STONE
4" CMU BLOCK
RIGID ROOF INSULATION
TYPICAL BEAM
BUILDING
INTERIOR
6' LONG #4 BAR PLACED IN CORES OF 8"
AND 4" CMU BLOCKS AND SURROUNDED
BY HIGH STRENGTH MORTAR
SCALE: 1-1/2" = 1'-0"
PROPOSED PARAPET ANCHORED ROD SECTION VIEW DETAIL
F7
1'-4"
6' LONG #4 BAR PLACED IN CORES OF 8"
AND 4" CMU BLOCKS AND SURROUNDED
BY HIGH STRENGTH MORTAR
4" CMU BLOCK
8" CMU BLOCK
7"
S100
SECTION DETAILS
EXISTING CAPSTONE
MASONRY MAT
NEW INSULATION
INSULATION TO BE REPLACED
FABRIC FLASHING AT ALL BEAMS
REMOVE ALL GROUT, MORTAR AND DEBRIS FROM AIR CAVITY
NOTES:
1. EXISTING CONDITIONS BASED OFF AS-BUILTS PROVIDED BY
GOVERNMENT, IF ANY DEVIATIONS OCCUR CONTACT THE EOR
IMMEDIATELY.
AE204
AE203
AE202
AE2055
AE2051 2
AE2053 4
AE151
AE151
AE2011
AE2012
AE202
AE203 2
AE204
AE206
20' - 10"
9' - 6" 17' - 1"
2 2 2
REPLACE CAST STONE JOINTS AT BUILDING EXTERIOR
NOT USED
NOT USED
REPAIR ROOF AT ENTRY CANOPY
REPLACE JOINTS AT CLERESTORY WINDOWS
CORRECT LEANING PARAPET WALL
CLEAN CAST STONE AT BUILDING EXTERIOR
NOT USED
NO WORK AT NEW ADDIDTION
NO WORK AT PARAPET AND EXTERIOR ELEVATION
NO WORK AT MECHANICAL PENTHOUSE
BID ITEMS
EXTERIOR REPAIR LEGEND
1 EXISTING FIRE DEPARTMENT CONNECTION
2 EXISTING BUILDING EXIT. EGRESS PATH FROM INTERIOR OF BUILDING TO
REMAIN OPEN DURING CONSTRUCTION. PROVIDE OVERHEAD PROTECTION
12' FROM EXTERIOR OF EXIT WHEN PERFORMING OVERHEAD WORK WITHIN
A 30' RADIUS OF THE EXIT
SAFETY NOTES LEGEND
3 SKYLIGHTS ARE NOT DESIGNED TO WITHSTAND FALL OR STEPPING ON.
PROVIDE ADEQUATE BARRIER AROUND SKYLIGHT PER OSHA 1926
4 CONTRACTOR TO PROVIDE ADEQUATE FALL PROTECTION AT PERIMETER
OF ROOF PER OSHA 1926. TYPICAL REQUIREMENT WHERE WORK IS DONE
WITHIN 10' OF EDGE OF ROOF.
5 CAULK IN THIS AREA FOUND TO CONTAIN ASBESTOS. ABATE PER
REQUIREMENTS IN ASBESTOS REPORT CREATED BY BRIGGS ASSOCIATES
Department of Veterans Affairs
Drawing Title Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Office of Construction and Facilities Management
CONSULTANTS:
Approved: Project Director
REPAIR BRICK FACADE
B-135
VA LYONS CAMPUS, VA NEW JERSEY
561A4-06-150
TJW GSE06/18/2018
BUILDING 135
612 NW Kay Drive | Lee's Summit | Missouri | 64063
(816) 525-9833 | (816) 472-5656 | tjw@tom-arch.com
SEAL:ARCHITECT/ENGINEER OF RECORD:
65% DESIGN SUBMISSION 08/25/2017
WATSON ENGINEERING, PC
1112 STATE ROUTE 434
OWEGO, NY 13827
(607) 223-4334
CMG
10727 W 128 ST
OVERLAND PARK, KS 66213
(913) 239-8900 AE101
ROOF PLAN
1" = 20'-0"
ROOF PLAN
B
A
C
D
E
A A
A
A
A
A
A A
A A
A
A
A
AA
A
A
A
A
A
A
A
A D
E
F
F F
G
H
J
J
J
J
J
J
J
J
G
G
G
G G
G
G
K
L
K
K
K
K
L
L
L
EXTENTS OF ROOF MEMBRANE AND INSULATION REMOVAL
REPLACE CAST STONE CAPSTONE
JOINTS AT BUILDING EXTERIOR
REPAIR BRICK AT BUILDING EXTERIOR.
PROTECT GLASS BELOW
AE500
** UNDERSIDE ** REMOVE EXISTING DRYWALL SOFFIT
AND REPLACE WITH PRE-FINISHED ALUM. SOFFIT
ON EXISTING METAL FRAMING SYSTEM
AE1512
AE151
Sim
AE151
Sim
AE151 2
S im
NEW ROOF MEMBRANE AND INSULATION
AE500
CRICKETS 1/4":1'-0" TYP.
CRICKETS 1/4":1'-0" TYP.
DO NOT BLOCK WEEP HOLES AT EXISTING WALL
DO NOT BLOCK WEEP HOLES AT EXISTING WALL
AE500
AE500
AE500
AE500
AE500 EXISTING ROOF MEMBRANE TO REMAIN
REPLACE SEALANT/ CAULK AT
WINDOW JOINTS
CLEAN DIRT AND DEBRIS FROM WINDOWS
ONCE CONSTRUCTION IS COMPLETED
*WINDOWS TO REMAIN
DEMOLITION NOTES
REMOVE EXISTING BUILT-UP ROOFING SYSTEM
INCLUDING INSULATION AND WOOD BLOCKING
DOWN TO EXISTING MTL DECK.
CLEAN, INSPECT AND PREPARE EXISTING MTL
ROOF DECK TO RECEIVE NEW ROOFING SYSTEM.
REMOVE EXISTING MTL COUNTER FLASHING AND
CAULK AT EXISTING BUILDING.
REMOVE EXISTING MTL COUNTER FLASHING AT
SKYLIGHTS. EXISTING PLYWOOD TO REMAIN.
EXISTING SKYLIGHT TO REMAIN.
EXISTING SKYLIGHT MTL CURB TO REMAIN.
REMOVE EXISTING MTL COUNTER FLASHING AND
SHEATHING BENEATH. EXISTING COPING TO
REMAIN.
EXISTING DRAIN TO REMAIN.
EXISTING MTL COUNTER FLASHING AT SKYLIGHT TO
REMAIN.
NOTE: ENTRANCE MUST REMAIN OPEN AT ALL TIMES.
REFERENCE CIVIL DRAWINGS FOR SCAFFOLDING LAYOUT.
1 EXISTING FIRE DEPARTMENT CONNECTION
2 EXISTING BUILDING EXIT. EGRESS PATH FROM INTERIOR OF BUILDING TO
REMAIN OPEN DURING CONSTRUCTION. PROVIDE OVERHEAD PROTECTION
12' FROM EXTERIOR OF EXIT WHEN PERFORMING OVERHEAD WORK WITHIN
A 30' RADIUS OF THE EXIT
SAFETY NOTES LEGEND
3 SKYLIGHTS ARE NOT DESIGNED TO WITHSTAND FALL OR STEPPING ON.
PROVIDE ADEQUATE BARRIER AROUND SKYLIGHT PER OSHA 1926
4 CONTRACTOR TO PROVIDE ADEQUATE FALL PROTECTION AT PERIMETER
OF ROOF PER OSHA 1926. TYPICAL REQUIREMENT WHERE WORK IS DONE
WITHIN 10' OF EDGE OF ROOF.
5 CAULK IN THIS AREA FOUND TO CONTAIN ASBESTOS. ABATE PER
REQUIREMENTS IN ASBESTOS REPORT CREATED BY BRIGGS ASSOCIATES
Department of Veterans Affairs
Drawing Title Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Office of Construction and Facilities Management
CONSULTANTS:
Approved: Project Director
REPAIR BRICK FACADE
B-135
VA LYONS CAMPUS, VA NEW JERSEY
561A4-06-150
TJW GSE06/18/2018
BUILDING 135
612 NW Kay Drive | Lee's Summit | Missouri | 64063
(816) 525-9833 | (816) 472-5656 | tjw@tom-arch.com
SEAL:ARCHITECT/ENGINEER OF RECORD:
65% DESIGN SUBMISSION 08/25/2017
WATSON ENGINEERING, PC
1112 STATE ROUTE 434
OWEGO, NY 13827
(607) 223-4334
CMG
10727 W 128 ST
OVERLAND PARK, KS 66213
(913) 239-8900 AE151
ENLARGED PLANS &
ELEVATIONS
1/4" = 1'-0"
DEMO CANOPY ROOF PLAN
1/4" = 1'-0"
CLERESTORY ROOF PLAN
1/4" = 1'-0"
NEW CANOPY ROOF PLAN
1/4" = 1'-0"
CLERESTORY ELEVATION
1 2
4 4
TOP OF MEMBRANE
8 1/2" ABOVE DECK
/4
S L O
P E
/4
S L O
P E
NOTE: ENTRANCE MUST REMAIN OPEN AT ALL TIMES.
REFERENCE CIVIL DRAWINGS FOR SCAFFOLDING LAYOUT.
N
N
N
REPLACE JOINTS AT EXTERIOR WINDOWS
REPAIR BRICK AT BUILDING EXTERIOR
REPAIR ROOF AT ENTRY CANOPY
NOT USED
NOT USED
CLEAN CAST STONE CAPSTONE AT BUILDING EXTERIOR
CLEAN BRICK FACADE
NOT USED
NOT USED
NO WORK AT MECHANICAL PENTHOUSE
EXTERIOR REPAIR LEGEND
Department of Veterans Affairs
Drawing Title Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Office of Construction and Facilities Management
CONSULTANTS:
Approved: Project Director
REPAIR BRICK FACADE
B-135
VA LYONS CAMPUS, VA NEW JERSEY
561A4-06-150
TJW GSE06/18/2018
BUILDING 135
612 NW Kay Drive | Lee's Summit | Missouri | 64063
(816) 525-9833 | (816) 472-5656 | tjw@tom-arch.com
SEAL:ARCHITECT/ENGINEER OF RECORD:
65% DESIGN SUBMISSION 08/25/2017
WATSON ENGINEERING, PC
1112 STATE ROUTE 434
OWEGO, NY 13827
(607) 223-4334
CMG
10727 W 128 ST
OVERLAND PARK, KS 66213
(913) 239-8900 AE201
EAST ELEVATION
B
A
C
D
E
1/8" = 1'-0"
EAST ELEVATION -1
B
BB
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
1/8" = 1'-0"
EAST ELEVATION - 2
BB
D
F
G
H
J
C
H
C
H
CC
H
C
CC
H
C
H
H H
HHHHH
AA A
K
L
LL
AA A
L
AGGG A
H
REPAIR BRICK AT BUILDING EXTERIOR
NOT USED
REPLACE JOINTS AT CLERESTORY WINDOWS
CORRECT LEANING PARAPET WALL
NOT USED
CLEAN BRICK FACADE
NO WORK AT NEW ADDIDTION
NOT USED
NO WORK AT MECHANICAL PENTHOUSE
EXTERIOR REPAIR LEGEND
Department of Veterans Affairs
Drawing Title Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Office of Construction and Facilities Management
CONSULTANTS:
Approved: Project Director
REPAIR BRICK FACADE
B-135
VA LYONS CAMPUS, VA NEW JERSEY
561A4-06-150
TJW GSE06/18/2018
BUILDING 135
612 NW Kay Drive | Lee's Summit | Missouri | 64063
(816) 525-9833 | (816) 472-5656 | tjw@tom-arch.com
SEAL:ARCHITECT/ENGINEER OF RECORD:
65% DESIGN SUBMISSION 08/25/2017
WATSON ENGINEERING, PC
1112 STATE ROUTE 434
OWEGO, NY 13827
(607) 223-4334
CMG
10727 W 128 ST
OVERLAND PARK, KS 66213
(913) 239-8900 AE202
NORTH ELEVATION
1/8" = 1'-0"
NORTH ELEVATION - 1
1/8" = 1'-0"
NORTH ELEVATION - 2
B
A
C
D
E
B B B B B
B B B B B
E
CC
B
B
B
B
B B B B B
B B B B B
F
F F F F
G
H
J
CCC
HHH
H
JJJ J J
J J
J J
J
J J J J J
H
CCC CC
H HHHH
J J
J
J J
J
JJ
JJJ
J
J
K
L
L
L
AA
AAA
AAAAA
REPAIR BRICK AT BUILDING EXTERIOR
NOT USED
NOT USED
NOT USED
CLEAN CAST STONE CAPSTONE AT BUILDING EXTERIOR
CLEAN BRICK FACADE
NOT USED
NO WORK AT PARAPET AND EXTERIOR ELEVATION
NO WORK AT MECHANICAL PENTHOUSE
EXTERIOR REPAIR LEGEND
Department of Veterans Affairs
Drawing Title Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Office of Construction and Facilities Management
CONSULTANTS:
Approved: Project Director
REPAIR BRICK FACADE
B-135
VA LYONS CAMPUS, VA NEW JERSEY
561A4-06-150
TJW GSE06/18/2018
BUILDING 135
612 NW Kay Drive | Lee's Summit | Missouri | 64063
(816) 525-9833 | (816) 472-5656 | tjw@tom-arch.com
SEAL:ARCHITECT/ENGINEER OF RECORD:
65% DESIGN SUBMISSION 08/25/2017
WATSON ENGINEERING, PC
1112 STATE ROUTE 434
OWEGO, NY 13827
(607) 223-4334
CMG
10727 W 128 ST
OVERLAND PARK, KS 66213
(913) 239-8900 AE203
WEST ELEVATIONS
1/8" = 1'-0"
WEST ELEVATION - 1
1/8" = 1'-0"
WEST ELEVATION - 2
B
A
C
D
E
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
OPEN BELOW
F
G
H
J
C C C C C C
H H H H H H
C C C C C
H H H H H H H H
H
K
L
L
G GGAAAA
AA A A
K
REPLACE CAST STONE CAPSTONE JOINTS AT BUILDING
EXTERIOR
REPLACE JOINTS AT EXTERIOR WINDOWS
REPAIR BRICK AT BUILDING EXTERIOR
NOT USED
NOT USED
NOT USED
CLEAN CAST STONE CAPSTONE AT BUILDING EXTERIOR
CLEAN BRICK FACADE
NOT USED
NO WORK AT PARAPET AND EXTERIOR ELEVATION
NO WORK AT MECHANICAL PENTHOUSE
EXTERIOR REPAIR LEGEND
Department of Veterans Affairs
Drawing Title Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Office of Construction and Facilities Management
CONSULTANTS:
Approved: Project Director
REPAIR BRICK FACADE
B-135
VA LYONS CAMPUS, VA NEW JERSEY
561A4-06-150
TJW GSE06/18/2018
BUILDING 135
612 NW Kay Drive | Lee's Summit | Missouri | 64063
(816) 525-9833 | (816) 472-5656 | tjw@tom-arch.com
SEAL:ARCHITECT/ENGINEER OF RECORD:
65% DESIGN SUBMISSION 08/25/2017
WATSON ENGINEERING, PC
1112 STATE ROUTE 434
OWEGO, NY 13827
(607) 223-4334
CMG
10727 W 128 ST
OVERLAND PARK, KS 66213
(913) 239-8900 AE204
SOUTH ELEVATIONS
1/8" = 1'-0"
SOUTH ELEVATION - 1
1/8" = 1'-0"
SOUTH ELEVATION - 2
B
A
C
D
E
B
B
B
B B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
F
G
H
J
C
H HH
H
CCCCCC C
HHH
HHH
K
L
AGGAAAAA A
L
L
GG AAAA
K K
K K
K
K
K
K
C
HHHH
C C C
HHH
REPAIR BRICK AT BUILDING EXTERIOR
NOT USED
NOT USED
NOT USED
CLEAN CAST STONE CAPSTONE AT BUILDING EXTERIOR
CLEAN BRICK FACADE
NOT USED
NO WORK AT PARAPET AND EXTERIOR ELEVATION
NOT USED
EXTERIOR REPAIR LEGEND
Department of Veterans Affairs
Drawing Title Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Office of Construction and Facilities Management
CONSULTANTS:
Approved: Project Director
REPAIR BRICK FACADE
B-135
VA LYONS CAMPUS, VA NEW JERSEY
561A4-06-150
TJW GSE06/18/2018
BUILDING 135
612 NW Kay Drive | Lee's Summit | Missouri | 64063
(816) 525-9833 | (816) 472-5656 | tjw@tom-arch.com
SEAL:ARCHITECT/ENGINEER OF RECORD:
65% DESIGN SUBMISSION 08/25/2017
WATSON ENGINEERING, PC
1112 STATE ROUTE 434
OWEGO, NY 13827
(607) 223-4334
CMG
10727 W 128 ST
OVERLAND PARK, KS 66213
(913) 239-8900 AE205
EAST/WEST ELEVATIONS
1/8" = 1'-0"
EAST ELEVATION - 3
1/8" = 1'-0"
WEST ELEVATION - 3
1/8" = 1'-0"
EAST ELEVATION - 4
1/8" = 1'-0"
WEST ELEVATION - 4
1/8" = 1'-0"
EAST ELEVATION - 5
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
A
C
D
E
F
G
H
J
K
L
A A A
A A A
A A A
G G G
G G G
H
HHH
H H
H
HHHHH
H
H H H
H
HHH
H
C C CC
CCCC
CCC CC
K
K
REPLACE CAST STONE CAPSTONE JOINTS AT BUILDING
EXTERIOR
REPLACE JOINTS AT EXTERIOR WINDOWS
REPAIR BRICK AT BUILDING EXTERIOR
NOT USED
NOT USED
NOT USED
CLEAN CAST STONE CAPSTONE AT BUILDING EXTERIOR
CLEAN BRICK FACADE
NOT USED
NOT USED
NOT USED
EXTERIOR REPAIR LEGEND
Department of Veterans Affairs
Drawing Title Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Office of Construction and Facilities Management
CONSULTANTS:
Approved: Project Director
REPAIR BRICK FACADE
B-135
VA LYONS CAMPUS, VA NEW JERSEY
561A4-06-150
TJW GSE06/18/2018
BUILDING 135
612 NW Kay Drive | Lee's Summit | Missouri | 64063
(816) 525-9833 | (816) 472-5656 | tjw@tom-arch.com
SEAL:ARCHITECT/ENGINEER OF RECORD:
65% DESIGN SUBMISSION 08/25/2017
WATSON ENGINEERING, PC
1112 STATE ROUTE 434
OWEGO, NY 13827
(607) 223-4334
CMG
10727 W 128 ST
OVERLAND PARK, KS 66213
(913) 239-8900 AE206
COURTYARD
ELEVATIONS
1/8" = 1'-0"
COURTYARD - SOUTH ELEVATION
B
A
C
D
E
F
G
H
J
1/8" = 1'-0"
COURTYARD - WEST ELEVATION
1/8" = 1'-0"
COURTYARD - NORTH ELEVATION
1/8" = 1'-0"
COURTYARD - EAST ELEVATION
B B BB B B B
B B BB B B B
B B
B B
B B B
B B B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
K
L
AA
A A A
A A A A
A A A
G GA
CC C
HH H H
H
C C C
H H H
C C C C C C
H H H H H
CCCC
H
HH
FACE BRICK TO BE DEMOLISHED
TO EXISTING FLASHING
FIELD VERIFY
1' - 2" EXIST.
EXISTING ROOF
MEMBRANE
REMOVE EXISTING CAST STONE
COPING. STORE AND PROTECT
FOR RE-INSTALLATION
EXISTING 8" CMU
INSULATION TO BE REMOVED
FABRIC FLASHING AT ALL BEAMS
EXISTING FACE BRICK TO REMAIN
REMOVE ALL GROUT, MORTOR
AND DEBRIS FROM AIR CAVITY
NEW FACE BRICK
FIELD VERIFY
1' - 2" EXIST.
EXISTING ROOF
MEMBRANE
RE-INSTALL
EXISTING CAST
STONE COPING
EXISTING 8" CMU
THRU-WALL FLASHING
INSULATION
VAPOR BARRIER
WEEP @ 2'-0" O.C.
EXISTING FACE BRICK TO REMAIN
MASONRY MAT
VAPOR BARRIER TO RUN UP WALL
AND UNDER COPING STONE
FACE BRICK TO BE
DEMOLISHED
FIELD VERIFY
1' - 2" EXIST.
EXISTING ROOF
MEMBRANE TO REMAIN
REMOVE EXISTING CAST STONE
COPING. STORE AND PROTECT
FOR RE-INSTALLATION
EXISTING 8" CMU
INSULATIONTO BE REMOVED
FABRIC FLASHING AT ALL BEAMS
EXISTING FACE BRICK TO
REMAIN
REMOVE EXISTING METAL CAP
EXISTING SKYLIGHT TO BE PROTECTED
DURING CONSTRUCTION
EXISTING FACE BRICK AT AND
BELOW SKYLIGHT TO REMAIN
EXISTING FLASHING TO BE REMOVED
NEW FACE BRICK
FIELD VERIFY
1' - 2" EXIST.
EXISTING ROOF
MEMBRANE TO REMAIN
RE-INSTALL EXISTING
CAST STONE COPING
EXISTING 8" CMU
NEW INSULATION
FABRIC FLASHING AT ALL BEAMS
EXISTING FACE BRICK TO
REMAIN
EXISTING SKYLIGHT TO BE PROTECTED
DURING CONSTRUCTION
EXISTING FACE BRICK AT AND
BELOW SKYLIGHT TO REMAIN
MASONRY MAT
THRU-WALL FLASHING
SINGLE PLY SEALANT
METAL BAR COUNTER FLASHING
WEEP @ 2'-0" O.C.
SINGLE-PLY SEALANT
COUNTER FLASHING
BAR NAIL-IN
12" O.C. MAX
EPDM MEMBRANE FLASHING
FULLY ADHERED EPOXY ROOFING
CANT STRIP
TAPERED INSULATION
EXISTING MTL ROOF DECK
EPDM MEMBRANE FLASHING
FULLY ADHERED EPOXY ROOFING
CANT STRIP
TAPERED INSULATION
EXISTING MTL ROOF DECK
EXISTING SHEET MTL TO REMAIN
12" O.C. MAX.
EXISTING SHEATHING TO REMAIN
DENS EXTERIOR SHEATHING
F
IE
L D
V E
R
IF
Y
MTL COPING TO MATCH EXISTING
5"
EXISTING WOOD BLOCKING
EXISTING PRE-CAST PANELS
EXISTING MTL STUD SYSTEM
EXISTING MTL DECK
EPDM MEMBRANE FLASHING
FULLY ADHERED EPOXY ROOFING
CANT STRIP
TAPERED INSULATION
12" O.C. MAX.
DENS EXTERIOR SHEATHING
REMOVE EXISTING VENT AND DRYWALL
SOFFIT. INSTALL PRE-FINISHED ALUM.
SOFFIT PANELS OVER EXISTING METAL
FRAMING SYSTEM.
Department of Veterans Affairs
Drawing Title Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Office of Construction and Facilities Management
CONSULTANTS:
Approved: Project Director
REPAIR BRICK FACADE
B-135
VA LYONS CAMPUS, VA NEW JERSEY
561A4-06-150
TJW GSE06/18/2018
BUILDING 135
612 NW Kay Drive | Lee's Summit | Missouri | 64063
(816) 525-9833 | (816) 472-5656 | tjw@tom-arch.com
SEAL:ARCHITECT/ENGINEER OF RECORD:
65% DESIGN SUBMISSION 08/25/2017
WATSON ENGINEERING, PC
1112 STATE ROUTE 434
OWEGO, NY 13827
(607) 223-4334
CMG
10727 W 128 ST
OVERLAND PARK, KS 66213
(913) 239-8900 AE500
DETAILS
1 1/2" = 1'-0"
DEMO TYP. PARAPET SECTION
1 1/2" = 1'-0"
TYP. PARAPET SECTION
1 1/2" = 1'-0"
DEMO WALL SECTION
1 1/2" = 1'-0"
NEW WALL SECTION
1 1/2" = 1'-0"
SECTION @ CANOPY
1 1/2" = 1'-0"
SECTION @ SKYLIGHT
1 1/2" = 1'-0"
SECTION @ CANOPY PARAPET (TYP)
| Sheets |
| G001 - COVER SHEET |
| G002 - GENERAL INFORMATION |
| AE101 - ROOF PLAN |
| AE151 - ENLARGED PLANS & ELEVATIONS |
| AE201 - EAST ELEVATION |
| AE202 - NORTH ELEVATION |
| AE203 - WEST ELEVATIONS |
| AE204 - SOUTH ELEVATIONS |
| AE205 - EAST/WEST ELEVATIONS |
| AE206 - COURTYARD ELEVATIONS |
| AE500 - DETAILS |
File details come from the government source that posted it.