36A79718Q0008-0002001.pdf

PDF 64 KB Posted

Attached to
May 2018 Consolidation
Solicitation number
36A79718Q0008
Issued by

About this file

36A79718Q0008 0002 504-B87003 - XR PORT RAD, VAMC AMARILLO, TX Redacted.pdf

View the file

Other files

File Type Posted
36A79718Q0008-0002000.docx DOCX document
36A79718Q0008-0002003.pdf PDF
36A79718Q0008-0002002.pdf PDF
36A79718Q0008-00001001.xlsx XLSX spreadsheet
36A79718Q0008-00001000.docx DOCX document
36A79718Q0008-022.zip ZIP file
36A79718Q0008-015.zip ZIP file
36A79718Q0008-014.zip ZIP file
36A79718Q0008-026.zip ZIP file
36A79718Q0008-012.zip ZIP file
36A79718Q0008-005.pdf PDF
36A79718Q0008-007.xlsx XLSX spreadsheet
36A79718Q0008-029.pdf PDF
36A79718Q0008-024.zip ZIP file
36A79718Q0008-018.zip ZIP file
36A79718Q0008-011.zip ZIP file
36A79718Q0008-031.pdf PDF
36A79718Q0008-009.zip ZIP file
36A79718Q0008-027.zip ZIP file
36A79718Q0008-010.zip ZIP file
36A79718Q0008-008.zip ZIP file
36A79718Q0008-030.pdf PDF
36A79718Q0008-025.zip ZIP file
36A79718Q0008-028.xlsx XLSX spreadsheet
36A79718Q0008-023.zip ZIP file
36A79718Q0008-004.docx DOCX document
36A79718Q0008-017.zip ZIP file
36A79718Q0008-013.zip ZIP file
36A79718Q0008-019.zip ZIP file
36A79718Q0008-021.zip ZIP file
36A79718Q0008-020.zip ZIP file
36A79718Q0008-006.pdf PDF
36A79718Q0008-016.zip ZIP file
36A79718Q0008-000.docx DOCX document
36A79718Q0008-003.xlsx XLSX spreadsheet
36A79718Q0008-002.pdf PDF
36A79718Q0008-001.pdf PDF
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Item No.

Qty Description

1 Optima XR240amx Digital Mobile Radiographic system

The Optima XR240amx is a self-contained battery operated mobile radiographic digital X-ray imaging system designed for performing radiographic exams at the point of care

Key features

-30KW generator

-Compatible with FlashPad HD2530 and FlashPad HD3643 digital wireless detectors

-Dose Area Product Meter (DAP)

-Capable of 100 - 240V nominal, 50/60Hz operation

-Stand-by mode eliminates boot up cycles and allows the start of the imaging exam within 20 seconds.

Exposures can be taken and processed while the unit is charging

-FashPad HD detector batteries charge automatically while the detector(s) are in the bin when the system is on, or in standby mode

-Tether cord

-Optimized GUI - Technique, image acquisition and display tools in a single integrated user interface

-FlashPad HD detectors can be shared across compatible systems within the healthcare facility by all users.

REQUESTING SERVICE: RADIOLOGY ( 114)

SHIP TO:

WAREHOUSE B87003

V.A. Medical Center

6010 AMARILLO BLVD. WEST

AMARILLO, TX 79106

P.O.# 504-B87003

Qty Description

Please refer to the current literature for system compatibility.

-Drive inhibit keypad access

-Password protected access to patient

-Information for compliance with confidentiality regulations

-Automatic safety brake: Operator must hold drive handles to allow system to move

-Integrated front bumper stops unit and activates brakes when activated

Productivity:

-Less than 4.5 hours to go from 20% to 100% for system battery charge

-System can be driven within 4 seconds of activation

-Pre-programmed techniques per anatomy, view, and patient size

-System can be used without the detector. Designed for use with films or CR Cassettes

Auto Protocol Assist

Repeat/Reject Analysis

Please note: The standard warranty for Optima XR240amx base system including batteries is 2 years from Equipment Acceptance, excluding the wireless detector. All other warranty terms limitations and exceptions identified in the GE Healthcare Warranty Statement remain in full force and effect.

2 FlashPad HD3543 (14" x 17" Wireless digital detector):

Qty Description

- Detector battery can take up to 60 exposures per hour and provide enough power for 5 hours of use on a single charge

- Single panel (non-tiled) amorphous silicon detector with a directly deposited cesium iodide scintillator

- Pixel pitch 100 microns

- Pixel matrix: 3524 x 4288 pixels

- Typical DQE @ 0lp/mm: 75%

- Include QAP (Quality Assurance Procedure)

- Available with 6:1 or 8:1 removable grids

- Image area: (13.8 in x 16.6 in)

- Weight: 3.2kb (7.1 lbs)

- 802.11n 5GHz link between system and detector

- Supports automatic channel switching to improve image transfer and avoid wireless interference with hospital network

3 DETECTOR BATTERY 14X17IN

4 6:1 Grid for FlashPad HD3543

5 Battery charger for FlashPad HD3543 (14" x 17" Wireless digital detector):

The external desktop charger is intended to charge up to two Flashpad HD3543 rechargeable lithium#ion batteries simultaneously.

The external desktop charger:

- Displays the status of the battery packs

- Contains two charging bays. Status

Qty Description lights on the charger indicate the status of each battery pack

- Will charge the battery in up to three hours, depending on the initial state of charge

- Is keyed to accept the battery in one orientation

6 Wireless Connectivity for Optima XR220amx and Optima XR200amx

802.11 a/b/g n-compatible wireless connectivity to hospital network

Wi-Fi Certified

Compatible with:

• 802.11i, Wi-Fi Protected Access

2 (WPA2), WPA 802.1X

• AES - TKIP

• 64-, 128-WEP

• VPN: IPSec - IKE

• Management Frame Protection (MFP) EAP Types:

- LEAP

- LEAP + 128-WEP

- LEAP + WPA

- EAP - TLS

- EAP-TTLS/MSCHAPv2

- EAP-FAST

- PEAP-GTC

- PEAP/MSCHAPV2

7 1 Expert Training Package

6 days (4 consecutive +2 day follow up)

Educational Program to be used when

Qty Description training greater than 8 users.

Optima240 Service Training for 2 Biomeds 8 Optima XR220AMX, XR200AMX, &

Brivo XR285AMX Full Service Training (Class/Lab) (3 Days)

This service training class covers all three mobile X-ray systems Optima XR220AMX, XR200AMX, and Brivo XR285AMX. Engineer must have have completed XR Basic Service R0182RY & R0181RY or equivalent experience before attending this course. This course must be taken within 2 years from the purchase date.

File details come from the government source that posted it.