3. - CC-622-230-001 BCCC LSB Restroom Renov. Bid Set.pdf
PDF 7 MB Posted
- Attached to
- CC-622-230-001
- Solicitation number
- BPM057964
- Issued by
- Maryland
About this file
This is a Bid Set for architectural and engineering contract documents prepared by the State of Maryland Department of General Services for the Baltimore City Community College Life Science Building Restroom Renovations project located at 2901 Liberty Heights Avenue, Baltimore, Maryland 21215, with DGS Project Number CC-622-230-001. The project encompasses comprehensive restroom renovations on the first, second, third, and fourth floors of the building, including demolition of existing fixtures and installation of new plumbing, HVAC, electrical, and architectural systems. The renovation work is a one-for-one fixture replacement with no change to the existing fixture count. The project involves removal and replacement of water closets, urinals, lavatories, toilets, toilet partitions, floor drains, and all associated finishes including wall tile, flooring, ceiling systems, and interior accessories. New fixtures specified include American Standard water closets, urinals, and lavatories with touchless Selectronic faucets. The work requires compliance with 2021 IBC Building Code, 2021 IPC International Plumbing Code, 2021 IMC International Mechanical Code, 2020 NEC National Electrical Code, and 2019 Maryland Accessibility Code standards. The bid set was issued May 5, 2026, and includes complete architectural, plumbing, HVAC, and electrical drawings with specifications prepared by Noelker and Hull Associates Inc., Architects and Edge Engineers.
The contract documents include detailed floor plans, demolition plans, elevation plans, reflected ceiling plans, plumbing and HVAC schedules, electrical power and lighting plans, and finish schedules specifying materials such as porcelain tile flooring, ceramic tile wall treatments in various colors by DalTile and Garden State Tile, quartz countertops, acoustical ceiling tiles, and solid plastic toilet partitions. Minority Business Enterprises are encouraged to respond to this solicitation. The project requires contractors to provide labor for demolition, coordination with existing building systems, installation of new fixtures and finishes, field verification of all dimensions, shop drawing submissions, testing and commissioning, as-built documentation, and operation and maintenance manuals. All work must maintain fire ratings of existing floors, walls, and ceilings, coordinate with mechanical, electrical, and plumbing systems, and comply with ADA accessibility requirements including grab bar placement, accessible sink heights, and accessible parking facilities. Contractors are responsible for all permits, licenses, and inspection fees, safe handling and protection of materials, and warranty of work against defects for not less than one year from final acceptance.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BCCC LIFE SCIENCE BUILDING RESTROOM RENOVATIONS
2901 LIBERTY HEIGHTS AVE,
BALTIMORE, MARYLAND 21215
DGS PROJECT NO. CC-622-230-001
BID SET
MAY 05, 2026
STATE OF MARYLAND
DEPARTMENT OF GENERAL SERVICES
ATIF CHAUDHRY, SECRETARY OF
MARYLAND DEPARTMENT OF GENERAL SERVICES
ROOM 1405
301 WEST PRESTON STREET
BALTIMORE, MARYLAND 21201
BOARD OF PUBLIC WORKS
WES MOORE, GOVERNOR OF MARYLAND
BROOKE ELIZABETH LIERMAN, COMPTROLLER OF MARYLAND
DERECK E. DAVIS, TREASURER OF MARYLAND
USING AGENCY APPROVAL
G002 CODE ANALYSIS
PROJECT COVER SHEET
P001 PLUMBING INDEX SHEET
P101 PLUMBING & HVAC DEMOLITION AND NEW WORK PLANS
P201 PLUMBING & HVAC DETAILS AND SCHEDULES
E00 ELECTRICAL COVER SHEET
E01 PARTIAL DEMOLITION PLANS
E02 PARTIAL FLOOR PLANS POWER AND LIGHTING AND DETAILS
NORTH
NORTH
PROJECT MANAGER DATE
DATE
DATE
DEPARTMENT OF
GENERAL SERVICES
APPROVAL
CHIEF OF PM & D
NAME
PROJECT LOCATION
BALTIMORE, MD State Capital
NUMBER
CODE ANALYSIS
A101 FIRST AND SECOND FLOOR RESTROOM DEMOLITION, NEW WORK,
AND REFLECTED CEILING PLANS
A102 FIRST AND SECOND FLOOR RESTROOM ELEVATION PLANS AND FINISH NOTES
ARCHITECTURAL
PLUMBING
ELECTRICAL
The Contract Documents for the indicated public improvement were prepared under my supervision and, to the best of my knowledge and belief, they comply with the relevant building codes of the State of Maryland.
Signature_________________________Date_________________ License #___________, Expiration Date_____/_____/________
NOELKER AND HULL ASSOCIATES INC. ARCHITECTS
The Contract Documents for the indicated public improvement were prepared under my supervision and, to the best of my knowledge and belief, they comply with the relevant building codes of the State of Maryland.
Signature_________________________Date_________________ License #___________, Expiration Date_____/_____/________
EDGE ENGINEERING
VICINITY MAP
LOCATION MAP
DRAWING INDEX
SHEET NAME PHASE & DATEA/E NAMES ADDRESSES
NOELKER AND HULL
ASSOCIATES, INC.
ARCHITECTS
6 NORTH EAST STREET, SUITE 300
FREDERICK, MD 21701-5680
P: 301.662.8611 F: 301.662.8632
NOELKERHULL.COM
EDGE ENGINEERS
925 FELL STREET
BALTIMORE, MD 21231
P: 443.708.2320 edge-engineers.com
BID SET - 05/05/2026
THIRD AND FOURTH FLOOR RESTROOM DEMOLITION, NEW WORK,
AND REFLECTED CEILING PLANS
A104 THIRD AND FOURTH FLOOR RESTROOM ELEVATION PLANS
A103
BID SET - 05/05/2026
BID SET - 05/05/2026
BID SET - 05/05/2026
BID SET - 05/05/2026
BID SET - 05/05/2026
BID SET - 05/05/2026
BID SET - 05/05/2026
BID SET - 05/05/2026
BID SET - 05/05/2026
BID SET - 05/05/2026
BID SET - 05/05/2026
SHEET ________ OF __________1 12
01/06/2026
01/06/2026
M Thomas (Jun 10, 2026 13:02:53 EDT) 10/06/2026
USE GROUP MATRIX:
COLLEGE BUILDING
2021 IBC
BUSINESS - B
(NONSEPERATED USE w/ MIXED USE)
CONSTRUCTION TYPE MATRIX:
COLLEGE BUILDING
2021 IBC
TYPE II B
FULLY SPRINKLERED (NFPA 13)
HEIGHT ANALYSIS:
COLLEGE BUILDING
2021 IBC
4 STORY / 75 FEET
ALLOWABLE # STORIES / ALLOWABLE HEIGHT
ACTUAL # OF STORIES / ACTUAL HEIGHT
4 STORIES
FIRE RESISTANCE SCHEDULE:
STRUCTURAL FRAME (COLUMNS, GIRDERS, TRUSSES)
2021 IBC NFPA 101 REMARKSPROVIDED
EXTERIOR BEARING WALLS
INTERIOR BEARING WALLS
ROOF CONSTRUCTION
FIRE WALLS
FIRE BARRIER
FIRE PARTITION
0 HOUR
0 HOUR
0 HOUR
0 HOUR
N/A N/A
1 HOUR w/ 3/4
HOUR OPENINGS
FLOOR CONSTRUCTION 0 HOUR
SMOKE BARRIER 1 HOUR w/ 1/3
HOUR OPENINGS
1 HOUR w/ 1/3
HOUR OPENINGS
SMOKE PARTITION (CORRIDORS) 0 HOUR 0 HOUR
GROSS AREA:
FIRST FLOOR
AREA (GROSS SQ. FT.)
12,400 SQ. FT.
CODE ANALYSIS SUMMARY
2018 NFPA 101
NEW OFFICE BUILDING
(NONSEPERATED USE w/ MIXED USE)
2018 NFPA 101
TYPE II (000)
FULLY SPRINKLERED (NFPA 13)
2018 NFPA 101
N/A
ALLOWABLE # STORIES / ALLOWABLE HEIGHT
SECOND FLOOR 25,950 SQ. FT.
1 HOUR w/ 3/4
HOUR OPENINGS
1 HOUR w/ 1/3
HOUR OPENINGS
1 HOUR w/ 1/3
HOUR OPENINGS
0 HOUR
0 HOUR
0 HOUR
0 HOUR
0 HOUR
2 HOUR
N/A
1 HOUR
N/A
N/A
0 HOUR
N/A
N/A
N/A
N/A
APPLICABLE CODES
PROJECT:
APPLICABLE CODES:
2021 IBC BUILDING CODE (MPC)
2021 IRC INTERNATIONAL ENERGY CONSERVATION CODE (MPC)
2019 MARYLAND ACCESSIBILITY CODE
2018 IPC INTERNATIONAL PLUMBING CODE (EFFECTIVE DECEMBER 30, 2019)
2021 IMC INTERNATIONAL MECHANICAL CODE (MPC)
2020 NEC NATIONAL ELECTRICAL CODE (MPC)
2018 ICC INTERNATIONAL FUEL GAS CODE (IFGC) WITH LOCAL AMENDMENTS
2018 NFPA 1 AND 2018 NFPA 101
2021 IBC AND COMAR 09.12.55 - SAFETY GLAZING
2021 IBC AND LABOR REQUIREMENT - ELEVATOR/CONVEYING SYSTEM
2018 IFC INTERNATIONAL FUEL AND GAS CODE (EFFECTIVE DECEMBER 30, 2019)
2019 (REV JAN 2022) DEPARTMENT OF GENERAL SERVICES - PROCEDURE MANUAL FOR PROFESSIONAL SERVICES
MARYLAND HIGH PERFORMANCE GREEN BUILDING PROGRAM
BALTIMORE CITY COMMUNITY COLLEGE
2901 LIBERTY HEIGHTS AVE,
BALTIMORE, MD 21215
1. ALL DIMENSIONS ARE TAKEN FROM THE FACE OF FINISH, FACE OF FINISH, UON.
2. DO NOT SCALE THE DRAWINGS.
3. IF DRAWING SET IS TO BE PRINTED THE SET MUST BE PRINTED IN COLOR AS SOME
GRAPHICAL INFORMATION USE COLORS BEYOND BASIC BLACK OR GRAY TONES.
4. PROJECT CLASSIFICATION CODE: C
5. COUNTY - BALTIMORE CITY COUNTY
6. MINORITY BUSINESS ENTERPRISES ARE ENCOURAGED TO RESPOND TO THIS SOLICITATION.
PROJECT GENERAL NOTES
FIXTURE TYPE
FIXTURES REQUIRED
FIXTURES PROVIDED
DRINKING
FOUNTAINS
MOP SINKS
B = 1/100
PER CODE TOTAL PER PROJECT
WATER CLOSETS B = 8 MALE (SEE URINALS)
16 FEMALE
B = 1/25 (FIRST 50)
1/50 (REMAINDER EXCEEDING 50) MALES & FEMALES
URINALS PER SECTION 424.2: CAN REPLACE 50% OF WATER CLOSETS. 8 MAXIMUM
LAVORATORIES
B = 1 SINK 1 MINIMUM
521 OCC
5.21
5.72 MALE + 5.72 FEMALE
B = 4
B = 4 (ONE EACH FLOOR)
521 OCC (521/2 = 261)
PLUMBING SYSTEMS (2018 IPC INTERNATIONAL PLUMBING CODE - TABLE 403.1)
B = 8 MALE
B = 1/40 (FIRST 40)
1/80 (REMAINDER EXCEEDING 80) MALES & FEMALES
3.76 MALE + 3.76 FEMALE
521 OCC (521/2 = 261) B = 8 MALE
8 FEMALE
THIRD FLOOR 20,350 SQ. FT.
FOURTH FLOOR 19,390 SQ. FT.
78,090 SQ. FT.
(ONE EACH FLOOR)
NOTE:
1. THIS PROJECT IS A 1 FOR 1 FIXTURE REPLACEMENT AND
EXISTING FIXTURE COUNT TOTAL IS NOT CHANGING.
PLAN
NORTH
TRUE NORTH
M ay
, 2
6 -
:03 pm
Baltimore | Philadelphia
925 Fell Street Baltimore, MD|21231 P: 443.708.2320
MEP ENGINEER
EDGE ENGINEERS
SHEET INFORMATION
PROJECT ADDRESS
PROJECT OWNER
KEY PLAN
PROJECT INFORMATION
ISSUED FOR
PROJECT TEAM
JOB NUMBER:
SHEET TITLE:
SHEET NUMBER:
PROJECT TITLE
6 NORTH EAST STREET, SUITE 300
FREDERICK, MD | 21701-5680
P: 301.662.8611 | F: 301.662.8632
NOELKERHULL.COM
© 2026 NOELKER AND HULL ASSOCIATES, INC.
SHEET _______OF ________
CAD DWG FILE:
DRAWN BY: NHA
CHK'D BY: NHA
DESCRIPTION: DATE:
The Contract Documents for the indicated public improvement were prepared under my supervision and, to the best of my knowledge and belief, they comply with the relevant building codes of the State of Maryland.
Signature_________________________Date_________________ License #___________, Expiration Date_____/_____/________ edge-engineers.com
ENTRANCE
(FIRST FLOOR)
STAIRSTAIR
ELEV ELEV
STAIR
AREA OF WORK
05/05/2026BID SET
2901 LIBERTY HEIGHTS AVE,
BALTIMORE, MD 21215
BCCC LIFE SCIENCE
BUILDING RESTROOM
RENOVATIONS
tds
23913 & DGS CC-622-230-001
G002
CODE ANALYSIS
2 12
ABBREVIATIONS NOTES
ACW ALUMINUM CLAD WOOD MWF MOLDED WOOD FIBER HW-1 3 BALL BEARING HINGES 1 PULL
FW FLUSH WOOD TG TEMPERED GLASS 1 DOOR STOP 1 PUSH
HM HOLLOW METAL TIG TEMPERED INSULATED GLASS 1 DEADLOCK 1 CLOSER
IHM INSULATED HOLLOW METAL SWD SOLID WOOD 1 THUMB TURN ON INSIDE
DOOR SCHEDULE
FIRST FLOOR
DOOR DATA FRAME DATA
REMARKS
MARK TYPE SIZE MAT'L GLAZING RATING HARDWARE TYPE MAT'L HEAD JAMB SILL
111 A 3'-0" x 7'-0" SWD - - HW-1 F-1 STEEL - - -
112 A 3'-0" x 7'-0" SWD - 90 MIN. HW-1 F-1 STEEL - - -
DOOR SCHEDULE
SECOND FLOOR
DOOR DATA FRAME DATA
REMARKS
MARK TYPE SIZE MAT'L GLAZING RATING HARDWARE TYPE MAT'L HEAD JAMB SILL
226 A 3'-0" x 7'-0" SWD - - HW-1 F-1 STEEL - - -
227 A 3'-0" x 7'-0" SWD - - HW-1 F-1 STEEL - - -
1. REFER TO AND COORDINATE WITH MECHANICAL, ELECTRICAL,
PLUMBING, AND FIRE PROTECTION DRAWINGS AND SPECIFICATIONS
FOR ADDITIONAL DEMOLITION WORK REQUIRED BUT NOT INDICATED
ON THIS DRAWING.
2. FOR DEMOLITION AND PATCHING OF WALLS REQUIRING NEW
FINISHES, REFER TO FINISH SCHEDULE FOR MATERIALS.
3. CONTRACTOR TO MAINTAIN FIRE RATINGS OF ALL FLOORS, WALLS
AND CEILINGS. FILL ALL VOIDS, HOLES AND OPENINGS CREATED DUE
TO DEMOLITION WITH APPROVED RATED CONSTRUCTION MATERIALS
OR FIRE SAFING MATERIAL TO MAINTAIN THE FIRE RATING OF THE
FLOORS, WALLS AND CEILINGS.
4. SALVAGED EQUIPMENT AND/OR FURNISHINGS TO BE COORDINATED
w/ OWNER.
SYMBOL DESCRIPTION
EXISTING CONSTRUCTION
TO BE REMOVED:
DRAWN DASHED
EXISTING
CONSTRUCTION TO
REMAIN:
DRAWN LIGHT
DEMOLITION KEYNOTE
DEMOLITION LEGEND
GENERAL DEMOLITION NOTES
REMOVE ALL WALL FINISHES DOWN TO STUD WALLS/HAT CHANNEL;
PATCH AND REPAIR WALL TO RECEIVE NEW WALL FINISH
REMOVE ALL GYPSUM CEILING, ACCESS PANEL, LIGHT
FIXTURES, AND OTHER SYSTEM ITEMS; REFER TO MEP FOR
ADDITIONAL SYSTEM DEMOLITION.
REMOVE MARBLE THRESHOLD REPAIR FLOOR TO
RECEIVE NEW THRESHOLD
REMOVE DOOR, FRAME, AND HARDWARE IN ITS ENTIRETY; PATCH
AND REPAIR AS REQUIRED; TYPICAL
REMOVE ALL VANITY & PLUMBING FIXTURES
REMOVE ALL TOILET PARTITIONS
REMOVE ALL TOILETS AND ACCESSORIES
REMOVE ALL FLOOR FINISHES TO SUBSTRATE; PATCH
AND REPAIR FLOOR TO RECEIVE NEW FLOOR FINISH
NOTE DESCRIPTION
DEMOLITION NOTES
SALVAGE AND RE-INSTALL IN SAME LOCATION EXISTING FIRE
ALARM AND STROBE; COORDINATE WITH MEP WORK
REMOVE PORTION OF WALL; PATCH AND REPAIR AS REQUIRED; TYP.10
11 REMOVE FLOOR DRAIN AND REPLACE WITH NEW; COORDINATE
WITH NEW FLOOR FINISHES AND MEP WORK.
REMOVE DOOR, FRAME, AND HARDWARE IN ITS ENTIRETY; PREP
OPENING FOR NEW DOOR AND FRAME; REFER TO DOOR SCHEDULE
5A
SCALE:
FIRST FLOOR TOILET PLAN
1/4" = 1'-0"
A101SCALE:
SECOND FLOOR TOILET PLAN
1/4" = 1'-0"
A101
SCALE:
FIRST FLOOR TOILET DEMOLITION PLAN
1/4" = 1'-0"
A101SCALE:
SECOND FLOOR TOILET DEMOLITION PLAN
1/4" = 1'-0"
A101
SCALE:
DOOR TYPES
1/4" = 1'-0"
A101SCALE:
FRAME TYPES
1/4" = 1'-0"
A101
SEE
SCHEDULE
SE
E
SC
HE
DU
LE
2" 2"
2"
F-1
SEE
SCHEDULE
SE
E
SC
HE
DU
LE
A
1 2 3 6 7 8
55A 1 2 3 6 7 8
1 2 3 6 7 8
1 2 3 6 7 8
MEN
WOMEN
EX. F.D.
AREA OF WORK
MECHANICAL
ROOM
114A
ELEVATOR
ROOM
EX. F.D.
2HFB
2HFB
2HFB
2H
FB
2H
FB
2HFB
2H
FB
2HFB 2HFB 2HFB 2HFB 2HFB 2HFB 2HFB
2H
FB
ELEV
F
F
55A
MEN
WOMEN
EX. F.D.
AREA OF WORK
ELEC.
213B
EX. F.D.
2HFB
2HFB
2HFB2HFB
2H
FB
2H
FB
2HFB 2HFB
HFB
2HFB
2H F
HFB
2HFB 2HFB 2HFB
2H F
ELEV
F
F
55A
55A
MEN
WOMEN
EX. F.D.
AREA OF WORK
MECHANICAL
ROOM
114A
ELEVATOR
ROOM
EX. F.D.
2HFB
2HFB
2HFB
2H
FB
2H
FB
2HFB
2H
FB
2HFB 2HFB 2HFB 2HFB 2HFB 2HFB 2HFB
2H
FB
ELEV
F
F
MEN
WOMEN
- 9
'-0
V.
I.F
2"
2'-6" 2"
3'-0" 2"
3'-0" 2"
5'-1"
+/- 20'-61 2" (V.I.F.)
- 9
'-0
V.
I.F
2"
3'-0" 2"
3'-0" 2"
3'-0" 2"
5'-1"
4" M
AX
2'- 8"
MI
N.
5'- 0"
1 2"
2'-
4" M
AX
2'- 8"
MI
N.
4'- 8"
1 2"
1'-6"+/- 3'-10"1'-6"
1'-6"+/- 3'-4"1'-6"
229 SQ.FT.
229 SQ.FT.
± 8'-0" AFF
(V.I.F.)
± 8'-0" AFF
(V.I.F.)
4'-4"
4'-4"
1'-
"1'-61 2"
1'-
"1'-61 2"
2'-6" 2'-6"
1'-
2'-6" 2'-6"
1'-
F
F
RE-INSTALLED FIRE ALARM STROBE,
COORDINATE W/ ELECTRICAL
RE-INSTALLED FIRE ALARM STROBE,
COORDINATE W/ ELECTRICAL
F.D.
F.D.
MEN
WOMEN
EX. F.D.
AREA OF WORK
ELEC.
213B
EX. F.D.
2HFB
2HFB
2HFB2HFB
2H
FB
2H
FB
2HFB 2HFB
HFB
2HFB
2H F
HFB
2HFB 2HFB 2HFB
2H F
ELEV
F
F
MEN
WOMEN
- 9
'-0
V.
I.F
+/- 20'-7" (V.I.F.)
2"
3'-0" 2"
3'-0" 2"
3'-0" 2"
5'-1"
4" M
AX
2'- 8"
MI
N.
4'- 8"
1 2"
4'-4"
1'-6"+/- 3'-41 2"1'-6"
2"
2'-6" 2"
3'-0" 2"
3'-0" 2"
5'-1"
- 9
'-0
V.
I.F
4" M
AX
2'- 8"
MI
N.
5'- 0"
1 2"
2'-
1'-6"+/- 3'-101 2"1'-6"
4'-4"
230 SQ.FT.
231 SQ.FT.
± 8'-0" AFF
(V.I.F.)
± 8'-0" AFF
(V.I.F.)
1'-
"1'-41 2"
1'-41 2"
1'-
2'-6" 2'-6"
1'-
1'-
" 2'-6"2'-6"
F
F
RE-INSTALLED FIRE ALARM STROBE,
COORDINATE W/ ELECTRICAL
RE-INSTALLED FIRE ALARM STROBE,
COORDINATE W/ ELECTRICAL
EXISTING SPRINKLER HEADS TO
REMAIN IN PLACE AND PROTECTED
DURING CONSTRUCTION
F.D.
F.D.
NOTE:
1. MAINTAIN EXISTING FLOOR SLOPES TO
(F.D.) MINIMAL SLOPE OF 1/8" PER 1'-0".
NOTE:
1. MAINTAIN EXISTING FLOOR SLOPES TO
(F.D.) MINIMAL SLOPE OF 1/8" PER 1'-0".
10 10
SCALE:
FIRST FLOOR TOILET PLAN
1/4" = 1'-0"
A101SCALE:
SECOND FLOOR TOILET PLAN
1/4" = 1'-0"
A101
SCALE: 1/4" = 1'-0"SCALE: 1/4" = 1'-0"
SCALE:
DOOR TYPES
1/4" = 1'-0"
A101SCALE:
FRAME TYPES
1/4" = 1'-0"
A101
SEE
SCHEDULE
SE
E
SC
HE
DU
LE
2" 2"
2"
F-1
SEE
SCHEDULE
SE
E
SC
HE
DU
LE
A
AREA OF WORK
MECHANICAL
ROOM
114A
ELEVATOR
ROOM
2HFB
2HFB
2HFB
2H
FB
2H
FB
2HFB
2H
FB
2HFB 2HFB 2HFB 2HFB 2HFB 2HFB 2HFB
2H
FB
ELEV
MEN
WOMEN
- 9
'-0
V.
I.F
2"
2'-6" 2"
3'-0" 2"
3'-0" 2"
5'-1"
+/- 20'-61 2" (V.I.F.)
- 9
'-0
V.
I.F
2"
3'-0" 2"
3'-0" 2"
3'-0" 2"
5'-1"
4" M
AX
2'- 8"
MI
N.
5'- 0"
1 2"
2'-
4" M
AX
2'- 8"
MI
N.
4'- 8"
1 2"
1'-6"+/- 3'-10"1'-6"
1'-6"+/- 3'-4"1'-6"
229 SQ.FT.
229 SQ.FT.
4'-4"
4'-4" F
F
RE-INSTALLED FIRE ALARM STROBE,
COORDINATE W/ ELECTRICAL
RE-INSTALLED FIRE ALARM STROBE,
COORDINATE W/ ELECTRICAL
F.D.
F.D.
AREA OF WORK
ELEC.
213B
2HFB
2HFB
2HFB2HFB
2H
FB
2H
FB
2HFB 2HFB
HFB
2HFB
2H F
HFB
2HFB 2HFB 2HFB
2H F
ELEV
MEN
WOMEN
- 9
'-0
V.
I.F
+/- 20'-7" (V.I.F.)
2"
3'-0" 2"
3'-0" 2"
3'-0" 2"
5'-1"
4" M
AX
2'- 8"
MI
N.
4'- 8"
1 2"
4'-4"
1'-6"+/- 3'-41 2"1'-6"
2"
2'-6" 2"
3'-0" 2"
3'-0" 2"
5'-1"
- 9
'-0
V.
I.F
4" M
AX
2'- 8"
MI
N.
5'- 0"
1 2"
2'-
1'-6"+/- 3'-101 2"1'-6"
4'-4"
230 SQ.FT.
231 SQ.FT.
F
F
RE-INSTALLED FIRE ALARM STROBE,
COORDINATE W/ ELECTRICAL
RE-INSTALLED FIRE ALARM STROBE,
COORDINATE W/ ELECTRICAL
F.D.
F.D.
NOTE:
1. MAINTAIN EXISTING FLOOR SLOPES TO
(F.D.) MINIMAL SLOPE OF 1/8" PER 1'-0".
NOTE:
1. MAINTAIN EXISTING FLOOR SLOPES TO
(F.D.) MINIMAL SLOPE OF 1/8" PER 1'-0".
SCALE:
FIRST FLOOR REFLECTED CEILING PLAN
1/4" = 1'-0"
A101SCALE:
SECOND FLOOR REFLECTED CEILING PLAN
1/4" = 1'-0"
A101
MECHANICAL
ROOM
114A
ELEVATOR
ROOM
2HFB 2HFB 2HFB 2HFB 2HFB 2HFB 2HFB
2H
FB
± 8'-0" AFF
(V.I.F.)1'-
"1'-61
2"2'-6" 2'-6"
1'-
" F
RE-INSTALLED FIRE ALARM STROBE,
COORDINATE W/ ELECTRICAL
AREA OF WORK
MECHANICAL
ROOM
114A
ELEVATOR
ROOM
2HFB
2HFB
2HFB
2H
FB
2H
FB
2HFB
2H
FB
2HFB 2HFB 2HFB 2HFB 2HFB 2HFB 2HFB
2H
FB
2H
ELEV
MEN
WOMEN
229 SQ.FT.
229 SQ.FT.
± 8'-0" AFF
(V.I.F.)
± 8'-0" AFF
(V.I.F.)
1'-
"1'-61 2"
1'-
"1'-61 2"
2'-6" 2'-6"
1'-
2'-6" 2'-6"
1'-
F
F
RE-INSTALLED FIRE ALARM STROBE,
RE-INSTALLED FIRE ALARM STROBE,
COORDINATE W/ ELECTRICAL
REMAIN IN PLACE AND PROTECTED
DURING CONSTRUCTION
ELEC.
213B
HFB
2HFB
2H F
HFB
2HFB 2HFB 2HFB
2H F
WOMEN
± 8'-0" AFF
(V.I.F.)1'-
"1'-41 2"2'-6" 2'-6"
1'-
" F
EXISTING SPRINKLER HEADS TO
REMAIN IN PLACE AND PROTECTED
DURING CONSTRUCTION
AREA OF WORK
ELEC.
213B
2HFB
2HFB
2HFB2HFB
2H
FB
2H
FB
2HFB 2HFB
HFB
2HFB
2H F
HFB
2HFB 2HFB 2HFB
2H F
ELEV
MEN
WOMEN
230 SQ.FT.
231 SQ.FT.
± 8'-0" AFF
(V.I.F.)
± 8'-0" AFF
(V.I.F.)
1'-
"1'-41 2"
1'-41 2"
1'-
2'-6" 2'-6"
1'-
1'-
" 2'-6"2'-6"
F
F
EXISTING SPRINKLER HEADS TO
REMAIN IN PLACE AND PROTECTED
DURING CONSTRUCTION
2' x 2' ACOUSTICAL CEILING GRID
LIGHTING LEGEND
2' x 2' LED LIGHT FIXTURE
MATERIAL LEGEND
WALL MOUNTED LED FIXTURE
SPRINKLER
MECHANICAL LEGEND
SUPPLY DIFFUSER
EXHAUST GRILLE
A101
FIRST AND SECOND FLOOR RESTROOM
DEMOLITION, NEW WORK, AND
REFLECTED CEILING PLANS
PLAN
NORTH
TRUE NORTH
M ay
, 2
6 -
1:
pm
Baltimore | Philadelphia
925 Fell Street Baltimore, MD|21231 P: 443.708.2320
MEP ENGINEER
EDGE ENGINEERS
SHEET INFORMATION
PROJECT ADDRESS
PROJECT OWNER
KEY PLAN
PROJECT INFORMATION
ISSUED FOR
PROJECT TEAM
JOB NUMBER:
SHEET TITLE:
SHEET NUMBER:
PROJECT TITLE
6 NORTH EAST STREET, SUITE 300
FREDERICK, MD | 21701-5680
P: 301.662.8611 | F: 301.662.8632
NOELKERHULL.COM
© 2026 NOELKER AND HULL ASSOCIATES, INC.
SHEET _______OF ________
CAD DWG FILE:
DRAWN BY: NHA
CHK'D BY: NHA
DESCRIPTION: DATE:
The Contract Documents for the indicated public improvement were prepared under my supervision and, to the best of my knowledge and belief, they comply with the relevant building codes of the State of Maryland.
Signature_________________________Date_________________ License #___________, Expiration Date_____/_____/________ edge-engineers.com
ENTRANCE
(FIRST FLOOR)
STAIRSTAIR
ELEV ELEV
STAIR
AREA OF WORK
05/05/2026BID SET
2901 LIBERTY HEIGHTS AVE,
BALTIMORE, MD 21215
BCCC LIFE SCIENCE
BUILDING RESTROOM
RENOVATIONS
tds
23913 & DGS CC-622-230-001
3 12 2 2 4 6 8 10
1/4" = 1'-0"
FEETSCALE
TOILET ACCESSORY SCHEDULE
TAG NO. DESCRIPTION CP/ CI OP / CI
TA-1B GRAB BAR: 18" LONG (VERTICAL) X
TA-1C NOT USED
TA-1D NOT USED
TA-1E GRAB BAR: 36" LONG X
TA-1F GRAB BAR: 42" LONG X
TA-1G NOT USED
TA-2 PAPER TOWEL (FOLDED) DISPENSER X
TA-3 MIRROR: 24" X 36" X
TA-4 COAT HOOK X
TA-5 TOILET TISSUE (JUMBO-ROLL) DISPENSER X
TA-6 WASTE RECEPTACLE, SURFACE MOUNTED X
TA-7 LIQUID-SOAP DISPENSER, WALL MOUNTED X
TA-8 SANITARY-NAPKIN & TAMPON DISPENSER X
TA-9 SANITARY-NAPKIN DISPOSAL UNIT, PARTITION MOUNTED X
TA-10 WARM-AIR DRYER X
TA-11 HAND SANITIZER DISPENSER, WALL MOUNTED X
TA-12 DIAPER CHANGING STATION X
TA-13 SEAT COVER DISPENSER X
FINISH PLAN GENERAL NOTES
1 THE FINISH ABBREVIATION LEGEND IS STANDARD, NOT ALL MATERIALS ARE NECESSARILY USED.
2 PAINT FIRE EXTINGUISHER CABINET EXTERIOR TRIM AND DOOR TO MATCH ADJACENT WALL
COLOR, TYP.
3 PAINT GRILLS, LOUVERS AND ACCESS PANELS TO MATCH COLOR OF ADJACENT
MATERIAL, TYP.
4 TRANSITION STRIP COLORS LOCATED BETWEEN ADJACENT FLOORING MATERIALS SHALL BE
SELECTED BY ARCHITECT.
5 WALL TILE SHALL EXTEND FLOOR TO CEILING ON ALL WALLS.
6 ALL HOLLOW METAL DOOR FRAMES SHALL BE PAINTED PNT-1 TYP.
7 HIGHLIGHTED WALLS ON PLANS INDICATE WALL MATERIAL LOCATIONS AND EXTENTS.
8 A102 SHALL BE PRINTED IN COLOR.
INTERIOR FINISH ABBREVIATIONS
ACT ACOUSTICAL CEILING TILE PT PORCELAIN TILE
AP ACOUSTICAL PANEL QT QUARRY TILE
AWC ACOUSTICAL WALLCOVERING QZ QUARTZ
BR BUMPER RAIL RB RUBBER BASE
CGS CEILING SYSTEM RES RESINOUS POURED FLOORING
CC CUBICLE CURTAIN RF RESILIENT FLOORING
CG CORNER GUARD RT RUBBER TILE
CHR CHAIR RAIL SC SPECIALITY COATING
CM CULTURED MARBLE SCONC SEALED CONCRETE
CPT CARPET SHC SHOWER CURTAIN
CR CRASH RAIL SMP SOLID MINERAL PROFILE PANELING
CT CERAMIC TILE SP SOLID PHENOLIC
DM DECORATIVE METAL SR SHEET RUBBER
DP DOOR PROTECTION SS SOLID SURFACE
DPG DECORATIVE PLASTIC GLAZING ST STAIR TREADS
EP EPOXY PAINT STCONC STAINED CONCRETE
FA FABRIC SV SHEET VINYL
FRP FIBERGLASS REINFORCED PANEL TF THERMOFOIL
GL GLASS TP TOILET PARTITION
GT GLASS TILE TZ TERRAZZO
HR HAND RAIL VB VINYL BASE
LR LEANING RAIL VCT VINYL COMPOSITION TILE
LVT LUXURY VINYL TILE WC WALLCOVERING
MT METAL TILE WD WOOD
NS NATURAL STONE WOM WALK-OFF MAT
PNT PAINT WP WALL PROTECTION
PLAM PLASTIC LAMINATE WT WINDOW TREATMENT
PSTR PAINTED STRUCTURE
INTERIOR FINISH SCHEDULE
SYMBOL MANUFACTURER PRODUCT NAME, NUMBER & COLOR PRODUCT LOCATIONS & DETAILS
064116 - PLASTIC LAMINATE FACED ARCHITECTURAL CABINETS
PLAM-1 WILSONART PATTERN: BLACKBIRD. 5024K-19; FINISH: LENO WEAVE TEXTURE FOR USE IN: MENS TYPICAL VANITY PLUMBING ENCLOSURE PLAM-2 WILSONART PATTERN: MUSHROOM. 5013K-19; FINISH: LENO WEAVE TEXTURE FOR USE IN: WOMENS TYPICAL VANITY PLUMBING ENCLOSURE
093013 - TILE
PT-1 DALTILE
PRODUCT: LINDON POINT; COLOR: GRIGIO NO. LP21; SIZE: 12" X 24" X 5/16"; FINISH: MATTE; INSTALLATION METHOD: BRICK; RECOMMENDED GROUT WIDTH; 3/16"; GROUT: MAPEI COLOR: RAIN; TRIM: (COVE) SCHLUTER
DILEX-AHK; (BASE) SCHLUTER QUADEC; TRIM FINISH: SATIN NICKEL ANODIZED ALUMINUM
FOR USE IN: TYPICAL MENS AND WOMENS FLOOR TILE
PT-2 GARDEN STATE TILE
PRODUCT: TRANQUIL; COLOR: BRIGHT; SIZE: 12" X 24" X 5/16"; FINISH: HONED; INSTALLATION METHOD:
HORIZONTAL STRAIGHT STACK; RECOMMENDED GROUT WIDTH; 3/32"; GROUT: MAPEI COLOR: RAIN AT MENS / COLOR MOONBEAM AT WOMENS; TRIM: (OUTSIDE CORNER) SCHLUTER QUADEC; TRIM FINISH: SATIN NICKEL
ANODIZED ALUMINUM
FOR USE IN: TYPICAL MENS AND WOMENS WALL TILE
CT-1 DALTILE
PRODUCT: MYTHOLOGY; COLOR: TITAN NO. MY96; SIZE: 4" X 12" X UNDULATED ; FINISH: GLOSSY; INSTALLATION METHOD: HORIZONTAL BRICK; RECOMMENDED GROUT WIDTH: 1/16"; GROUT: MAPEI COLOR: RAIN; TRIM:
(OUTSIDE CORNER) SCHLUTER QUADEC; TRIM FINISH: SATIN NICKEL ANODIZED ALUMINUM
FOR USE IN: MENS ACCENT WALL TILE
CT-2 DALTILE
PRODUCT: MYTHOLOGY; COLOR: HARMONIA NO. MY92; SIZE: 4" X 12" X UNDULATED ; FINISH: GLOSSY;
INSTALLATION METHOD: HORIZONTAL BRICK; RECOMMENDED GROUT WIDTH: 1/16"; GROUT: MAPEI COLOR:
MOONBEAM; TRIM: (OUTSIDE CORNER) SCHLUTER QUADEC; TRIM FINISH: SATIN NICKEL ANODIZED ALUMINUM
FOR USE IN: WOMENS ACCENT WALL TILE
095100 - ACOUSTICAL CEILINGS
ACT-1 CERTAINTEED PRODUCT: CASHMERE HIGH NRC NO. CM-457NRCP; COLOR: WHITE; SIZE: 24" X 24" X 3/4; EDGE PROFILE: TRIM;
MATERIAL: MINERAL FIBER: NRC: .70: CAC: 32: GRID: EZ STAB CLASSIC; GRID COLOR: WHITE: GRID SIZE: 15/16 FOR USE IN: TYPICAL CEILING TILE
099000 - PAINT
PNT-1 SHERWIN WILLIAMS COLOR: INKWELL NO. SW6992; FINISH: SEMI-GLOSS FOR USE IN: DOOR FRAME PAINT PNT-2 SHERWIN WILLIAMS COLOR: KRYPTON NO. SW6247; FINISH: EGGSHELL FOR USE IN: MENS TLT ROOM WALLS NOT RECEIVING TILE PNT-3 SHERWIN WILLIAMS COLOR: TEMPERATE TAUPE NO. SW6037; FINISH; EGGSHELL FOR USE IN: WOMENS TLT ROOM WALL NOT RECEIVING TILE
102113.19 - PLASTIC TOILET COMPARTMENTS
TP-1 ASI GLOBAL PARTITIONS PRODUCT: SOLID PLASTIC; COLOR: BLUE 9509 FOR USE IN: MENS TOILET PARTITIONS / URINAL SCREENS TP-2 ASI GLOBAL PARTITIONS PRODUCT: SOLID PLASTIC; COLOR: CREAM 9235 FOR USE IN: WOMENS TOILET PARTITIONS
123661.19 - QUARTZ AGGLOMERATE COUNTERTOPS
QZ-1 PRISMAQUARTZ COLOR: CARRERA THASSOS; EDGE: EASED; SINK; REFER TO PLUMBING DRAWINGS FOR USE IN: MENS / WOMENS VANITY COUNTERTOPS
CASEWORK NOTES
1 FINISH ALL EXPOSED SURFACE OF CASEWORK, TYP.
2 FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION.
3 ANCHORING DEVICES FOR ALL CASEWORK SHALL BE CERTIFIED FOR WITHDRAWAL LOADS. USE OF
EPANSION ANCHORS IS NOT ACCEPTABLE
4 CAULK PERIMETER AT ALL CASEWORK AND COUNTERTOP
WALL TILE AND PAINT LEGEND
PT-2
CT-1
CT-2
PNT-2
PNT-3
2'-
TO
R
IM
O F
SI
NK
1'- 51 2" 1" 71
2"
61 2" 4"
2'- 31 2"
SCALE:
ACCESSIBLE SINK VANITY DETAIL
3/4" = 1'-0"
A102
SIDE BACKSPLASH WHERE INDICATED ON
PLANS AND ELEVATIONS
SINK REFER TO PLUMBING DRAWINGS
WOOD BLOCKING AS REQUIRED
REMOVABLE ACCESS PANEL
FINISH AS SCHEDULED
REQUIRED TOE & KNEE CLEARANCE
11 2"
WALL FINISH AS SCHEDULED
INTEGRAL BACKSPLASH / SIDEPLASH
WHERE INDICATED ON ELEVATIONS
1'-10"
TYPICAL MOUNTING HEIGHT KEY (N.T.S.)
NOTE: ALL DIMS TO WALL OR FLOOR SURFACES ARE TO FACE OF FINISH
NOTE: ADA MOUNTING HEIGHTS ALL OTHER STANDARDS TOILETS SHALL BE 16"
9"
3'- 4"
TO
T
OW
EL
S
PAPER TOWEL
DISPENSER
MIRROR & LAVATORY & SOAP DISPENSER
(INC. LAVATORIES BUILT INTO CASEWORK)
2'- 3"
9"
2'- 5"2'-
TO
R
IM
O
F
SI
NK
2'- 3"
MI
N.
8"
MIN.
9" MI
N.
11"
MIN.
1'-5"
MIN.
URINALNAPKIN DISPOSAL
REQUIRED
KNEE & TOE
CLEARANCES
RECESSED
DISPENSER
2'-0"3'-6"
39" - 41"
16" - 18" 17" - 19"
ACCESSIBLE
AMBULATORY
CL
1'-0"
REAR GRAB BAR @ WHEELCHAIR
ACCESSIBLE CONFIGURATIONS
GRAB BARS AND TOILET
TISSUE DISPENSER
T.
O.
S
EA
T
PU
BL
IC
A
CC
ES
S
T.
O.
S
EA
T
TY
PE
A
B
U
NI
TS
SIDEWALL GRAB BARS
PROVIDE ON EACH SIDE
OF AMBULATORY STALLCL
1'- 6"1'-0"
2'- 9"
T O
3'- 0"
TO
T
OP
CL 1'-
3"
MI
N.
7" - 9"
11 2"
MI
N.
GRAB BARS REINFORCEMENT AT TOILETS
(ADAPTABLE UNITS)
3'- 2"
M
IN
2'- 8"
M
AX
2'-
0" 3'-10" MIN.
2" MAX.
6"3'-1"
4'-10" MIN.
8" MAX.
FLUSH VALVE TO
OPEN SIDE OF
ROOM - TYP.
EDGE OF
WALL
EDGE OF
WALL
EDGE OF
WALL
EDGE OF
WALL
EDGE OF
WALL
EDGE OF
WALL
1'- 5"
AC
CE
SS
IB
LE
EDGE OF
WALL
3'- 4"
M
AX
. T O
BO
TT
OM
OF
R
EF
LE
CT
ED
S
UR
FA
CE
EDGE OF
WALL
INSULATE
EXPOSED PIPING
3'- 4"
T O
BO
TT
OM
OF
S
OA
P
DI
SP
EN
SE
R
FIN. FLR.
ROOM
NAME
INTERIOR SIGNAGE
VISUAL
ROOM I.D.
BRAILLE
ROOM I.D.
" M
IN
" M
AX
FIN. FLR.
DOOR & DEVICES
LIGHT SWITCH
6"
CL
3'- 6"
CL
2'-
" M
IN
4'- 0"
M
AX
DOOR LEVER
4'- 0"
M
IN
5'- 0"
M
AX
TACTILE
AREA OF
REFUGE
SIGNAGE
" M
IN
" M
AX
W
OR
K
SU
RF
AC
E
4" MAX. (WHEN STOWED)
EDGE OF
WALL
CHILD CHANGING TABLE
" M
AX
20" MAX
SCALE:
SECOND FLOOR PLAN
1/4" = 1'-0"
A102 SCALE:
FIRST FLOOR PLAN
1/4" = 1'-0"
A102
SCALE:
MEN'S 111 / 226
1/4" = 1'-0"
A102
FLOOR, PT-1, TYP
FLOOR PT-1, TYP
A102
C
D
A
B
SCALE:
WOMENS 112 / 227
1/4" = 1'-0"
A102
A102
C
D
A
B
A102
A
D
C
B
EXTENT
OF CT-1
EXTENT
OF PT-2
EXTENT
OF PT-2
EXTENT
OF PT-2
FLOOR PT-1, TYP
FLOOR PT-1, TYP
AREA OF WORK
ELEC.
213B
2HFB
2HFB
2HFB2HFB
2H
FB
2H
FB
2HFB 2HFB
HFB
2HFB
2H F
HFB
2HFB 2HFB 2HFB
2H F
ELEV
MEN
WOMEN
230 SQ.FT.
231 SQ.FT.
F.D.
F.D.
EXTENT
OF PNT-3 E
AREA OF WORK
MECHANICAL
ROOM
114A
ELEVATOR
ROOM
2HFB
2HFB
2HFB
2H
FB
2H
FB
2HFB
2H
FB
2HFB 2HFB 2HFB 2HFB 2HFB 2HFB 2HFB
2H
FB
ELEV
MEN
WOMEN
229 SQ.FT.
229 SQ.FT.
F.D.
F.D.
TA-2
TA-6
TA-2
TA-6
TA-10
TA-11 TA-7
TA-4
TA-1E
TA-1F
TA-5
TA-1B
TA-5
TA-4
TA-4
TA-5
TA-4
TA-2
TA-6
TA-10
TA-9
TA-9
TA-12
TA-12
TA-7
TA-11
TA-1E
TA-1F
TA-5
TA-1B
TA-5
TA-9
TA-5
TA-9
TA-2
TA-6
TA-11
TA-3
TA-7
TA-4
TA-1E
TA-1F
TA-5
TA-1B
TA-5
TA-4
TA-1E
TA-1F
TA-5
TA-1B
TA-9
TA-5
TA-9
TA-12
TA-11
TA-7
TA-2 TA-2
TA-10
TA-4
TA-4
TA-12
TA-4TA-4
TA-5
TA-9
TA-5
TA-9
TA-6
TA-13
TA-8
TA-8
TA-13
EXTENT
OF PNT-2
EXTENT
OF PNT-3
EXTENT
OF PNT-2
TA-2
TA-6
TA-10
TA-3
TA-2
TA-6
CA
HC
A102
SIM.
A102
SIM.
- 8
'-0
V.
I.F
PT
-2
- 8 '-0
V.
I.F
PT
-2
- 8
'-0
V.
I.F
CT
-1
QZ-1
PLAM-2
QZ-1
PLAM-1
6'-9"
B D
CA B D
PT-2
PNT-2 (TYP WALL PAINT AT
WALLS NOT RECEIVING
WALL TILE)
PNT-3 (TYP WALL PAINT AT
WALLS NOT RECEIVING
WALL TILE)
PT-2
- 8 '-0
V.
I.F
CT
-2
6'-3"
PNT-3 (TYP WALL PAINT AT
WALLS NOT RECEIVING
WALL TILE)
COVE TRIM, SEE TRIM COVE
FOR PT-1 ON INTERIOR FINISH
SCHEDULE, TYP
OUTSIDE CORNER
TRIM, SEE INTERIOR
FINISH SCHEDULE, TYP
OUTSIDE CORNER TRIM,
SEE INTERIOR FINISH
SCHEDULE, TYP
TP-2 TYP.
TP-1 TYP.
COVE TRIM, SEE TRIM COVE
FOR PT-1 ON INTERIOR FINISH
SCHEDULE, TYP
COVE TRIM, SEE TRIM COVE
FOR PT-1 ON INTERIOR FINISH
SCHEDULE, TYP
COVE TRIM, SEE TRIM COVE
FOR PT-1 ON INTERIOR FINISH
SCHEDULE, TYP
COVE TRIM, SEE TRIM COVE
FOR PT-1 ON INTERIOR FINISH
SCHEDULE, TYP
COVE TRIM, SEE TRIM
COVE FOR PT-1 ON
INTERIOR FINISH
SCHEDULE, TYP
OUTSIDE CORNER
TRIM, SEE
INTERIOR FINISH
SCHEDULE, TYP
- 7
'-6
V.
I.F
PN
T-
CT-2
- 7
'-6
V.
I.F
CT
-2
TA-6
TA-2
TA-3
TA-7
TA-5 TA-5 TA-5
TA-1E
TA-3
TA-7TA-11
TA-5
TA-1E
TA-1B
TA-1F
TA-5
TA-11
TA-11
TA-1B
TA-1F
TA-5
TA-4
TA-9 TA-9 TA-9
TA-9
TA-10
TA-12
TA-2
TA-6
TA-8
TA-10
TA-4
TA-12
TA-2
TA-6
TA-2
TA-6
TA-13
TA-13
PT-1 CUT DOWN TO 6"H W/ BASE
PROFILE, SEE TRIM BASE FOR PT-1 IN
INTERIOR FINISH SCHEDULE, TYP
COVE TRIM, SEE TRIM COVE
FOR PT-1 ON INTERIOR FINISH
SCHEDULE, TYP
COVE TRIM, SEE TRIM COVE
FOR PT-1 ON INTERIOR FINISH
SCHEDULE, TYP
PT-1 CUT DOWN TO 6"H W/
BASE PROFILE, SEE TRIM
BASE FOR PT-1 IN INTERIOR
FINISH SCHEDULE, TYP
COVE TRIM, SEE TRIM COVE
FOR PT-1 ON INTERIOR FINISH
SCHEDULE, TYP
PT-1 CUT DOWN TO 6"H W/
BASE PROFILE, SEE TRIM
BASE FOR PT-1 IN INTERIOR
FINISH SCHEDULE, TYP
COVE TRIM, SEE TRIM COVE
FOR PT-1 ON INTERIOR FINISH
SCHEDULE, TYP
PNT-2 (TYP WALL PAINT AT
WALLS NOT RECEIVING
TILE)
6" 6"
6" 6"
NOTE:
REFER TO SHEET A104 FOR 3RD AND 4TH FLOOR INTERIOR ELEVATIONS.
NOTE:
REFER TO SHEET A104 FOR 3RD AND 4TH FLOOR INTERIOR ELEVATIONS.
A102
A
D
C
B
EXTENT
OF CT-1
EXTENT
OF CT-2
EXTENT
OF PT-2
EXTENT
OF CT-2
TA-13
TA-13
PT-1 CUT DOWN TO 6"H W/
BASE PROFILE, SEE TRIM
BASE FOR PT-1 IN INTERIOR
FINISH SCHEDULE, TYP
CT-1
TA-11
PT-2
CT-2
PT-2
CT-1
A102
FIRST AND SECOND FLOOR
RESTROOM ELEVATION PLANS
4 12
PLAN
NORTH
TRUE NORTH
M ay
, 2
6 -
1:
pm
Baltimore | Philadelphia
925 Fell Street Baltimore, MD|21231 P: 443.708.2320
MEP ENGINEER
EDGE ENGINEERS
SHEET INFORMATION
PROJECT ADDRESS
PROJECT OWNER
KEY PLAN
PROJECT INFORMATION
ISSUED FOR
PROJECT TEAM
JOB NUMBER:
SHEET TITLE:
SHEET NUMBER:
PROJECT TITLE
6 NORTH EAST STREET, SUITE 300
FREDERICK, MD | 21701-5680
P: 301.662.8611 | F: 301.662.8632
NOELKERHULL.COM
© 2026 NOELKER AND HULL ASSOCIATES, INC.
SHEET _______OF ________
CAD DWG FILE:
DRAWN BY: NHA
CHK'D BY: NHA
DESCRIPTION: DATE:
The Contract Documents for the indicated public improvement were prepared under my supervision and, to the best of my knowledge and belief, they comply with the relevant building codes of the State of Maryland.
Signature_________________________Date_________________ License #___________, Expiration Date_____/_____/________ edge-engineers.com
ENTRANCE
(FIRST FLOOR)
STAIRSTAIR
ELEV ELEV
STAIR
AREA OF WORK
05/05/2026BID SET
2901 LIBERTY HEIGHTS AVE,
BALTIMORE, MD 21215
BCCC LIFE SCIENCE
BUILDING RESTROOM
RENOVATIONS
tds
23913 & DGS CC-622-230-001
2 2 4 6 8 10 1/4" = 1'-0"
FEETSCALE
file:///J:/NH%20DRAFTING%20TOOLS/NH%20APPROVED%20BLOCKS/NH%20BLOCK%20PALETTES/Instruction%20Sheets/NH_Doors-SingleFrame_Elevation.doc file:///J:/NH%20DRAFTING%20TOOLS/NH%20APPROVED%20BLOCKS/NH%20BLOCK%20PALETTES/Instruction%20Sheets/NH_Doors-SingleFrame_Elevation.doc file:///J:/NH%20DRAFTING%20TOOLS/NH%20APPROVED%20BLOCKS/NH%20BLOCK%20PALETTES/Instruction%20Sheets/NH_Doors-SingleFrame_Elevation.doc
ABBREVIATIONS NOTES
ACW ALUMINUM CLAD WOOD MWF MOLDED WOOD FIBER HW-1 3 BALL BEARING HINGES 1 PULL
FW FLUSH WOOD TG TEMPERED GLASS 1 DOOR STOP 1 PUSH
HM HOLLOW METAL TIG TEMPERED INSULATED GLASS 1 DEADLOCK 1 CLOSER
IHM INSULATED HOLLOW METAL SWD SOLID WOOD 1 THUMB TURN ON INSIDE
DOOR SCHEDULE
THIRD FLOOR
DOOR DATA FRAME DATA
REMARKS
MARK TYPE SIZE MAT'L GLAZING RATING HARDWARE TYPE MAT'L HEAD JAMB SILL
313 A 3'-0" x 7'-0" SWD - - HW-1 F-1 STEEL - - -
314 A 3'-0" x 7'-0" SWD - - HW-1 F-1 STEEL - - -
DOOR SCHEDULE
FOURTH FLOOR
DOOR DATA FRAME DATA
REMARKS
MARK TYPE SIZE MAT'L GLAZING RATING HARDWARE TYPE MAT'L HEAD JAMB SILL
406 A 3'-0" x 7'-0" SWD - - HW-1 F-1 STEEL - - -
407 A 3'-0" x 7'-0" SWD - - HW-1 F-1 STEEL - - -
1. REFER TO AND COORDINATE WITH MECHANICAL, ELECTRICAL,
PLUMBING, AND FIRE PROTECTION DRAWINGS AND SPECIFICATIONS
FOR ADDITIONAL DEMOLITION WORK REQUIRED BUT NOT INDICATED
ON THIS DRAWING.
2. FOR DEMOLITION AND PATCHING OF WALLS REQUIRING NEW
FINISHES, REFER TO FINISH SCHEDULE FOR MATERIALS.
3. CONTRACTOR TO MAINTAIN FIRE RATINGS OF ALL FLOORS, WALLS
AND CEILINGS. FILL ALL VOIDS, HOLES AND OPENINGS CREATED DUE
TO DEMOLITION WITH APPROVED RATED CONSTRUCTION MATERIALS
OR FIRE SAFING MATERIAL TO MAINTAIN THE FIRE RATING OF THE
FLOORS, WALLS AND CEILINGS.
4. SALVAGED EQUIPMENT AND/OR FURNISHINGS TO BE COORDINATED
w/ OWNER.
SYMBOL DESCRIPTION
EXISTING CONSTRUCTION
TO BE REMOVED:
DRAWN DASHED
EXISTING
CONSTRUCTION TO
REMAIN:
DRAWN LIGHT
DEMOLITION KEYNOTE
DEMOLITION LEGEND
GENERAL DEMOLITION NOTES
REMOVE ALL WALL FINISHES DOWN TO STUD WALLS/HAT CHANNEL;
PATCH AND REPAIR WALL TO RECEIVE NEW WALL FINISH
REMOVE ALL GYPSUM CEILING, ACCESS PANEL, LIGHT
FIXTURES, AND OTHER SYSTEM ITEMS; REFER TO MEP FOR
ADDITIONAL SYSTEM DEMOLITION.
REMOVE MARBLE THRESHOLD REPAIR FLOOR TO
RECEIVE NEW THRESHOLD
REMOVE DOOR, FRAME, AND HARDWARE IN ITS ENTIRETY; PATCH
AND REPAIR AS REQUIRED; TYPICAL
REMOVE ALL VANITY & PLUMBING FIXTURES
REMOVE ALL TOILET PARTITIONS
REMOVE ALL TOILETS AND ACCESSORIES
REMOVE ALL FLOOR FINISHES TO SUBSTRATE; PATCH
AND REPAIR FLOOR TO RECEIVE NEW FLOOR FINISH
NOTE DESCRIPTION
DEMOLITION NOTES
SALVAGE AND RE-INSTALL IN SAME LOCATION EXISTING FIRE
ALARM AND STROBE; COORDINATE WITH MEP WORK
REMOVE PORTION OF WALL; PATCH AND REPAIR AS REQUIRED; TYP.10
11 REMOVE FLOOR DRAIN AND REPLACE WITH NEW; COORDINATE
WITH NEW FLOOR FINISHES AND MEP WORK.
REMOVE DOOR, FRAME, AND HARDWARE IN ITS ENTIRETY; PREP
OPENING FOR NEW DOOR AND FRAME; REFER TO DOOR SCHEDULE
5A
SCALE:
THIRD FLOOR TOILET PLAN
1/4" = 1'-0"
A103SCALE:
FOURTH FLOOR TOILET PLAN
1/4" = 1'-0"
A103
SCALE:
THIRD FLOOR TOILET DEMOLITION PLAN
1/4" = 1'-0"
A103SCALE:
FOURTH FLOOR TOILET DEMOLITION PLAN
1/4" = 1'-0"
A103
SCALE:
DOOR TYPES
1/4" = 1'-0"
A103SCALE:
FRAME TYPES
1/4" = 1'-0"
A103
SEE
SCHEDULE
SE
E
SC
HE
DU
LE
2" 2"
2"
F-1
SEE
SCHEDULE
SE
E
SC
HE
DU
LE
A
1 2 3 6 7 8
5A
1 2 3 6 7 8
1 2 3 6 7 8
1 2 3 6 7 8
5A
5A
5A
NOTE:
1. MAINTAIN EXISTING FLOOR SLOPES TO
(F.D.) MINIMAL SLOPE OF 1/8" PER 1'-0".NOTE:
1. MAINTAIN EXISTING FLOOR SLOPES TO
(F.D.) MINIMAL SLOPE OF 1/8" PER 1'-0".
MEN
WOMEN
ELEC.
317B
EX. F.D.
2HFB
2HFB
2HFB2HFB
2H
FB
2H
FB
2HFB 2HFB
2HFB
2HFB
2H
FB
2HFB
2HFB 2HFB 2HFB
2H
FB
ELEV
EX. F.D.
F
F
EX. F.D.
ELEC.
422A
2HFB
2HFB
2HFB2HFB
2H
FB
2H
FB
2HFB 2HFB
2HFB
2HFB
2H
FB
2HFB
2HFB 2HFB 2HFB
2H
FB
EX. F.D.
MEN
WOMEN
ELEV
F
F
MEN
WOMEN
- 9
'-0
V.
I.F
+/- 20'-7" (V.I.F.)
2"
3'-0" 2"
3'-0" 2"
3'-0" 2"
5'-1"
4" M
AX
2'- 8"
MI
N.
4'- 8"
1 2"
4'-4"
1'-6"+/- 3'-41 2"1'-6"
2"
2'-6" 2"
3'-0" 2"
3'-0" 2"
5'-1"
- 9
'-0
V.
I.F
4" M
AX
2'- 8"
MI
N.
5'- 0"
1 2"
2'-
1'-6"+/- 3'-101 2"1'-6"
4'-4"
230 SQ.FT.
231 SQ.FT.
± 8'-0" AFF
(V.I.F.)
± 8'-0" AFF
(V.I.F.)
1'-
1'-41 2"
1'-41 2"
1'-
MEN
WOMEN
ELEC.
317B
EX. F.D.
2HFB
2HFB
2HFB2HFB
2H
FB
2H
FB
2HFB 2HFB
2HFB
2HFB
2H
FB
2HFB
2HFB 2HFB 2HFB
2H
FB
ELEV
EX. F.D.
F
F
2'-6" 2'-6"
1'-
2'-6" 2'-6"
1'-
F
F
COORDINATE W/ ELECTRICAL
RE-INSTALLED FIRE ALARM STROBE,
COORDINATE W/ ELECTRICAL
EXISTING SPRINKLER HEADS TO
REMAIN IN PLACE AND PROTECTED
DURING CONSTRUCTION
F.D.
F.D.
MEN
EX. F.D.
ELEC.
422A
AREA OF WORK
2HFB
2HFB
2HFB2HFB
2H
FB
2H
FB
2HFB 2HFB
2HFB
2HFB
2H
FB
2HFB
2HFB 2HFB 2HFB
2H
FB
EX. F.D.
MEN
WOMEN
ELEV
F
F
WOMEN
- 9
'-0
V.
I.F
+/- 20'-7" (V.I.F.)
2"
3'-0" 2"
3'-0" 2"
3'-0" 2"
5'-1"
4" M
AX
2'- 8"
MI
N.
4'- 8"
1 2"
4'-4"
1'-6"+/- 3'-41 2"1'-6"
231 SQ.FT.
± 8'-0" AFF
(V.I.F.)1'-
1'-41 2"2'-6" 2'-6"
1'-
2"
2'-6" 2"
3'-0" 2"
3'-0" 2"
5'-1"
- 9
'-0
V.
I.F
4" M
AX
2'- 8"
MI
N.
5'- 0"
1 2"
2'-
1'-6"+/- 3'-101 2"1'-6"
4'-4"
± 8'-0" AFF
(V.I.F.)
1'-41 2"
1'-
2'-6" 2'-6" 1'-
F
F
RE-INSTALLED FIRE ALARM STROBE,
COORDINATE W/ ELECTRICAL
230 SQ.FT.
RE-INSTALLED FIRE ALARM STROBE,
COORDINATE W/ ELECTRICAL
EXISTING SPRINKLER HEADS TO
REMAIN IN PLACE AND PROTECTED
DURING CONSTRUCTION
F.D.
F.D.
SCALE:
THIRD FLOOR TOILET PLAN
1/4" = 1'-0"
A103SCALE:
FOURTH FLOOR TOILET PLAN
1/4" = 1'-0"
A103
SCALE: 1/4" = 1'-0"SCALE: 1/4" = 1'-0"
SCALE:
DOOR TYPES
1/4" = 1'-0"
A103SCALE:
FRAME TYPES
1/4" = 1'-0"
A103
SEE
SCHEDULE
SE
E
SC
HE
DU
LE
2" 2"
2"
F-1
SEE
SCHEDULE
SE
E
SC
HE
DU
LE
A
NOTE:
1. MAINTAIN EXISTING FLOOR SLOPES TO
(F.D.) MINIMAL SLOPE OF 1/8" PER 1'-0".NOTE:
1. MAINTAIN EXISTING FLOOR SLOPES TO
(F.D.) MINIMAL SLOPE OF 1/8" PER 1'-0".
MEN
WOMEN
- 9
'-0
V.
I.F
+/- 20'-7" (V.I.F.)
2"
3'-0" 2"
3'-0" 2"
3'-0" 2"
5'-1"
4" M
AX
2'- 8"
MI
N.
4'- 8"
1 2"
4'-4"
1'-6"+/- 3'-41 2"1'-6"
2"
2'-6" 2"
3'-0" 2"
3'-0" 2"
5'-1"
- 9
'-0
V.
I.F
4" M
AX
2'- 8"
MI
N.
5'- 0"
1 2"
2'-
1'-6"+/- 3'-101 2"1'-6"
4'-4"
230 SQ.FT.
231 SQ.FT.
ELEC.
317B
2HFB
2HFB
2HFB2HFB
2H
FB
2H
FB
2HFB 2HFB
2HFB
2HFB
2H
FB
2HFB
2HFB 2HFB 2HFB
2H
FB
ELEV
F
F
COORDINATE W/ ELECTRICAL
RE-INSTALLED FIRE ALARM STROBE,
COORDINATE W/ ELECTRICAL
F.D.
F.D.
MEN
ELEC.
422A
AREA OF WORK
2HFB
2HFB
2HFB2HFB
2H
FB
2H
FB
2HFB 2HFB
2HFB
2HFB
2H
FB
2HFB
2HFB 2HFB 2HFB
2H
FB
ELEV
WOMEN
- 9
'-0
V.
I.F
+/- 20'-7" (V.I.F.)
2"
3'-0" 2"
3'-0" 2"
3'-0" 2"
5'-1"
4" M
AX
2'- 8"
MI
N.
4'- 8"
1 2"
4'-4"
1'-6"+/- 3'-41 2"1'-6"
231 SQ.FT.
2"
2'-6" 2"
3'-0" 2"
3'-0" 2"
5'-1"
- 9
'-0
V.
I.F
4" M
AX
2'- 8"
MI
N.
5'- 0"
1 2"
2'-
1'-6"+/- 3'-101 2"1'-6"
4'-4"
F
F
RE-INSTALLED FIRE ALARM STROBE,
COORDINATE W/ ELECTRICAL
230 SQ.FT.
RE-INSTALLED FIRE ALARM STROBE,
COORDINATE W/ ELECTRICAL
F.D.
F.D.
SCALE:
THIRD FLOOR REFLECTED CEILING PLAN
1/4" = 1'-0"
A103SCALE:
FOURTH FLOOR REFLECTED CEILING PLAN
1/4" = 1'-0"
A103
± 8'-0" AFF
(V.I.F.)1'-
1'-41 2"
ELEC.
317B
2HFB
2HFB
2H
FB
2HFB
2HFB 2HFB 2HFB
2H
FB
2'-6" 2'-6"
1'-
" F
EXISTING SPRINKLER HEADS TO
REMAIN IN PLACE AND PROTECTED
DURING CONSTRUCTION
ELEC.
422A
2HFB
2HFB
2H
FB
2HFB
2HFB 2HFB 2HFB
2H
FB
F
EXISTING SPRINKLER HEADS TO
REMAIN IN PLACE AND PROTECTED
DURING CONSTRUCTION
MEN
ELEC.
422A
2HFB
2HFB
2HFB2HFB
2H
FB
2H
FB
2HFB 2HFB
2HFB
2HFB
2H
FB
2HFB
2HFB 2HFB 2HFB
2H
FB
ELEV
WOMEN
231 SQ.FT.
± 8'-0" AFF
(V.I.F.)1'-
1'-41 2"2'-6" 2'-6"
1'-
± 8'-0" AFF
(V.I.F.)
1'-41 2"
1'-
2'-6" 2'-6"
1'-
F
F
230 SQ.FT.
EXISTING SPRINKLER HEADS TO
REMAIN IN PLACE AND PROTECTED
DURING CONSTRUCTION
MEN
WOMEN
230 SQ.FT.
231 SQ.FT.
± 8'-0" AFF
(V.I.F.)
± 8'-0" AFF
(V.I.F.)
1'-
1'-41 2"
1'-41 2"
1'-
ELEC.
317B
2HFB
2HFB
2HFB2HFB
2H
FB
2H
FB
2HFB 2HFB
2HFB
2HFB
2H
FB
2HFB
2HFB 2HFB 2HFB
2H
FB
ELEV
2'-6" 2'-6"
1'-
2'-6" 2'-6"
1'-
F
F
EXISTING SPRINKLER HEADS TO
REMAIN IN PLACE AND PROTECTED
DURING CONSTRUCTION
2' x 2' ACOUSTICAL CEILING GRID
LIGHTING LEGEND
2' x 2' LED LIGHT FIXTURE
MATERIAL LEGEND
WALL MOUNTED LED FIXTURE
SPRINKLER
MECHANICAL LEGEND
SUPPLY DIFFUSER
EXHAUST GRILLE
A103
THIRD AND FOURTH FLOOR RESTROOM
DEMOLITION, NEW WORK, AND
REFLECTED CEILING PLANS
PLAN
NORTH
TRUE NORTH
M ay
, 2
6 -
1:
pm
Baltimore | Philadelphia
925 Fell Street Baltimore, MD|21231 P: 443.708.2320
MEP ENGINEER
EDGE ENGINEERS
SHEET INFORMATION
PROJECT ADDRESS
PROJECT OWNER
KEY PLAN
PROJECT INFORMATION
ISSUED FOR
PROJECT TEAM
JOB NUMBER:
SHEET TITLE:
SHEET NUMBER:
PROJECT TITLE
6 NORTH EAST STREET, SUITE 300
FREDERICK, MD | 21701-5680
P: 301.662.8611 | F: 301.662.8632
NOELKERHULL.COM
© 2026 NOELKER AND HULL ASSOCIATES, INC.
SHEET _______OF ________
CAD DWG FILE:
DRAWN BY: NHA
CHK'D BY: NHA
DESCRIPTION: DATE:
The Contract Documents for the indicated public improvement were prepared under my supervision and, to the best of my knowledge and belief, they comply with the relevant building codes of the State of Maryland.
Signature_________________________Date_________________ License #___________, Expiration Date_____/_____/________ edge-engineers.com
ENTRANCE
(FIRST FLOOR)
STAIRSTAIR
ELEV ELEV
STAIR
AREA OF WORK
05/05/2026BID SET
2901 LIBERTY HEIGHTS AVE,
BALTIMORE, MD 21215
BCCC LIFE SCIENCE
BUILDING RESTROOM
RENOVATIONS
tds
23913 & DGS CC-622-230-001
5 12 2 2 4 6 8 10
1/4" = 1'-0"
FEETSCALE
SCALE:
FOURTH FLOOR PLAN
1/4" = 1'-0"
A104 SCALE:
THIRD FLOOR PLAN
1/4" = 1'-0"
A104
SCALE:
MEN'S 313 / 406
1/4" = 1'-0"
A104
A104
C
D
A
B
A104
A
D
C
B
SCALE:
WOMENS 314 / 407
1/4" = 1'-0"
A104
EXTENT
OF CT-1
EXTENT
OF PT-2
FLOOR PT-1, TYP
FLOOR PT-1, TYP
MEN
ELEC.
422A
AREA OF WORK
2HFB
2HFB
2HFB2HFB
2H
FB
2H
FB
2HFB 2HFB
2HFB
2HFB
2H
FB
2HFB
2HFB 2HFB 2HFB
2H
FB
ELEV
WOMEN
231 SQ.FT.
230 SQ.FT.
F.D.
F.D.
MEN
WOMEN
230 SQ.FT.
231 SQ.FT.
AREA OF WORK
ELEC.
317B
2HFB
2HFB
2HFB2HFB
2H
FB
2H
FB
2HFB 2HFB
HFB
2HFB
2H F
HFB
2HFB 2HFB 2HFB
2H F
ELEV
F.D.
F.D.
A104
C
D
A
B
A104
A
D
C
B
EXTENT
OF CT-1
FLOOR PT-1, TYP
FLOOR PT-1, TYP
EXTENT
OF PNT-3
EXTENT
OF PNT-2 EXTENT
OF PT-2
EXTENT
OF CT-2
EXTENT
OF PNT-3
EXTENT
OF PNT-2
EXTENT
OF PT-2
EXTENT
OF PT-2
EXTENT
OF CT-2
TA-2
TA-6
TA-2
TA-6
TA-10
TA-11
TA-7
TA-4
TA-1E
TA-1F
TA-5
TA-1B
TA-5
TA-4
TA-4
TA-4
TA-2
TA-6
TA-2
TA-6
TA-10
TA-9
TA-9
TA-12
TA-12
TA-7
TA-11
TA-1E
TA-1F
TA-5
TA-1B
TA-5
TA-9
TA-5
TA-9
TA-13
TA-8
TA-2
TA-6
TA-2
TA-6TA-10
TA-11
TA-7
TA-4
TA-1E
TA-1F
TA-5
TA-1B
TA-5
TA-4
TA-4
TA-4
TA-2
TA-6
TA-2
TA-6
TA-10
TA-9
TA-9
TA-12
TA-12
TA-7
TA-11
TA-1E
TA-1F
TA-5
TA-1B
TA-5
TA-9
TA-5
TA-9
TA-13
TA-8
TA-3TA-3
CA
HC
A102
SIM.
A102
SIM.
- 8
'-0
V.
I.F
PT
-2
- 8 '-0
V.
I.F
PT
-2
- 8
'-0
V.
I.F
CT
-1
QZ-1
PLAM-2
QZ-1
PLAM-1
6'-9"
B D
CA B D
PT-2 (TYP WALL TILE AT
WALLS NOT RECEIVING
CT-2 WALL TILE)
PNT-2 (TYP WALL PAINT AT
WALLS NOT RECEIVING
WALL TILE)
PNT-3 (TYP WALL PAINT AT
WALLS NOT RECEIVING
WALL TILE)
PT-2
- 8
'-0
V.
I.F
CT
-1
- 8
'-0
V.
I.F
CT
-2
6'-3"
PNT-3 (TYP WALL PAINT AT
WALLS NOT RECEIVING
WALL TILE)
COVE TRIM, SEE TRIM COVE
FOR PT-1 ON INTERIOR FINISH
SCHEDULE, TYP
OUTSIDE CORNER
TRIM, SEE INTERIOR
FINISH SCHEDULE, TYP
OUTSIDE CORNER TRIM,
SEE INTERIOR FINISH
SCHEDULE, TYP
- 7
'-6
V.
I.F
PN
T-
TP-2 TYP.
TP-1 TYP.
COVE TRIM, SEE TRIM COVE
FOR PT-1 ON INTERIOR FINISH
SCHEDULE, TYP
COVE TRIM, SEE TRIM COVE
FOR PT-1 ON INTERIOR FINISH
SCHEDULE, TYP
COVE TRIM, SEE TRIM COVE
FOR PT-1 ON INTERIOR FINISH
SCHEDULE, TYP
COVE TRIM, SEE TRIM COVE
FOR PT-1 ON INTERIOR FINISH
SCHEDULE, TYP
COVE TRIM, SEE TRIM
COVE FOR PT-1 ON
INTERIOR FINISH
SCHEDULE, TYP
OUTSIDE CORNER
TRIM, SEE
INTERIOR FINISH
SCHEDULE, TYP
- 7
'-6
V.
I.F
PN
T-
- 8
'-0
V.
I.F
CT
-2
TA-6
TA-2
TA-3
TA-7
TA-5 TA-5 TA-5
TA-1E
TA-3
TA-7TA-11
TA-5
TA-1E
TA-1B
TA-1F
TA-5
TA-11
TA-11
TA-1B
TA-1F
TA-5
TA-4
TA-9 TA-9 TA-9
TA-9
TA-10
TA-12
TA-2
TA-6
TA-8
TA-10
TA-4
TA-12
TA-2
TA-6
TA-2
TA-6
TA-13
TA-13
PT-1 CUT DOWN TO 6"H W/ BASE
PROFILE, SEE TRIM BASE FOR PT-1 IN
INTERIOR FINISH SCHEDULE, TYP
COVE TRIM, SEE TRIM COVE
FOR PT-1 ON INTERIOR FINISH
SCHEDULE, TYP
COVE TRIM, SEE TRIM COVE
FOR PT-1 ON INTERIOR FINISH
SCHEDULE, TYP
PT-1 CUT DOWN TO 6"H W/
BASE PROFILE, SEE TRIM
BASE FOR PT-1 IN INTERIOR
FINISH SCHEDULE, TYP
COVE TRIM, SEE TRIM COVE
FOR PT-1 ON INTERIOR FINISH
SCHEDULE, TYP
PT-1 CUT DOWN TO 6"H W/
BASE PROFILE, SEE TRIM
BASE FOR PT-1 IN INTERIOR
FINISH SCHEDULE, TYP
COVE TRIM, SEE TRIM COVE
FOR PT-1 ON INTERIOR FINISH
SCHEDULE, TYP
PNT-2 (TYP WALL PAINT AT
WALLS NOT RECEIVING
TILE)
6"6"
6" 6"
CT-1
TA-13
TA-13TA-11
CT-1
PT-2
PT-2
PT-1 CUT DOWN TO 6"H W/
BASE PROFILE, SEE TRIM
BASE FOR PT-1 IN INTERIOR
FINISH SCHEDULE, TYP
A104
THIRD AND FOURTH FLOOR
RESTROOM ELEVATION PLANS
6 12
PLAN
NORTH
TRUE NORTH
M ay
, 2
6 -
1:
pm
Baltimore | Philadelphia
925 Fell Street Baltimore, MD|21231 P: 443.708.2320
MEP ENGINEER
EDGE ENGINEERS
SHEET INFORMATION
PROJECT ADDRESS
PROJECT OWNER
KEY PLAN
PROJECT INFORMATION
ISSUED FOR
PROJECT TEAM
JOB NUMBER:
SHEET TITLE:
SHEET NUMBER:
PROJECT TITLE
6 NORTH EAST STREET, SUITE 300
FREDERICK, MD | 21701-5680
P: 301.662.8611 | F: 301.662.8632
NOELKERHULL.COM
© 2026 NOELKER AND HULL ASSOCIATES, INC.
SHEET _______OF ________
CAD DWG FILE:
DRAWN BY: NHA
CHK'D BY: NHA
DESCRIPTION: DATE:
The Contract Documents for the indicated public improvement were prepared under my supervision and, to the best of my knowledge and belief, they comply with the relevant building codes of the State of Maryland.
Signature_________________________Date_________________ License #___________, Expiration Date_____/_____/________ edge-engineers.com
ENTRANCE
(FIRST FLOOR)
STAIRSTAIR
ELEV ELEV
STAIR
AREA OF WORK
05/05/2026BID SET
2901 LIBERTY HEIGHTS AVE,
BALTIMORE, MD 21215
BCCC LIFE SCIENCE
BUILDING RESTROOM
RENOVATIONS
tds
23913 & DGS CC-622-230-001
2 2 4 6 8 10 1/4" = 1'-0"
FEETSCALE
file:///J:/NH%20DRAFTING%20TOOLS/NH%20APPROVED%20BLOCKS/NH%20BLOCK%20PALETTES/Instruction%20Sheets/NH_Doors-SingleFrame_Elevation.doc file:///J:/NH%20DRAFTING%20TOOLS/NH%20APPROVED%20BLOCKS/NH%20BLOCK%20PALETTES/Instruction%20Sheets/NH_Doors-SingleFrame_Elevation.doc
1. MAINTAIN THE INTEGRITY OF ALL EXISTING PIPING SYSTEMS. PRIOR TO CONNECTING NEW WORK TO ANY EXISTING SYSTEM, CONFIRM SYSTEM IDENTIFICATION AND DIRECTION OF FLOW. VERIFY THAT EXISTING PIPING IDENTIFICATION LABELS ARE CORRECT, AND PROVIDE
ALL INSTALLATION REQUIREMENTS FOR PROPER CONNECTION TO THE EXISTING SYSTEMS.
2. PROVIDE ALL NECESSARY TEMPORARY OR PERMANENT CAPS OR PLUGS FOR PIPING. DO NOT LEAVE PIPING OPEN ENDED.
3. PRIOR TO STARTING CONSTRUCTION, DETERMINE EXACT INVERT ELEVATIONS, SIZE, DEPTH AND LOCATION OF ALL EXISTING UTILITIES WHERE CONNECTIONS ARE TO BE MADE OR INTERSECTIONS OCCUR. WORK BACK TOWARD FIXTURE FROM UTILITY CONNECTION FOR ALL
PIPING SYSTEMS.
4. PROVIDE THREE (3) ELBOW SWING JOINTS FOR ALL HOT WATER BRANCH CONNECTIONS TO THE MAIN.
5. INSTALL ALL SHOCK ABSORBERS IN ACCORDANCE WITH THE LATEST "PLUMBING AND DRAINAGE INSTITUTE" STANDARDS FOR WATER
HAMMER ARRESTORS.
6. LOCATE ACCESS PANELS IN NON ACCESSIBLE CEILINGS AND WALLS FOR ALL VALVES, SHOCK ABSORBERS, CLEANOUTS AND ALL OTHER ITEMS THAT REQUIRE ACCESS TO PROPERLY MAINTAIN OR SERVICE THE BUILDING. COORDINATE ALL FINAL LOCATIONS WITH ARCHITECT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY CAUSE A RELOCATION OF FIXTURES AND ACCESS PANELS WITHOUT ADDITIONAL EXPENSE
OR TIME TO THE PROJECT.
7. UNLESS OTHERWISE INDICATED, PIPING SHALL BE SUPPORTED FROM THE STRUCTURE ABOVE. INTERMEDIATE STRUCTURAL SUPPORTS SHALL BE PROVIDED IN AN APPROVED MANNER AS REQUIRED TO MEET MINIMUM SUPPORT SPACING REQUIRED BY THE SPECIFICATION.
8. PROVIDE HANGERS, ANCHORS, ETC., ON PIPING PER SUPPORT MANUFACTURER'S RECOMMENDATIONS.
9. INSTALL PIPING SO THAT VALVING IS ACCESSIBLE. PROVIDE ACCESS PANELS PER SPECIFICATIONS.
10. REFER TO ARCHITECTURAL DRAWINGS FOR ROOF, CEILING CONSTRUCTION TYPES AND DETAILS. WRAP EXPOSED PIPE IN ALL AREAS
11. EXISTING PIPING, VALVING, DUCTWORK, ELECTRICAL CONDUITS, ETC. EXIST WITHIN THE CEILING SPACE OTHER THAN THAT WHICH IS SHOWN ON THE CONTRACT DRAWINGS. VERIFY ALL CONDITIONS IN FIELD PRIOR TO FABRICATION.
12. COORDINATE NEW & DEMOLITION WORK WITH EXISTING WORK TO REMAIN SO AS NOT TO DAMAGE EXISTING WORK. ANY DAMAGE TO
EXISTING WORK TO REMAIN SHALL BE REPLACED/REPAIRED AT NO COST TO THE OWNER.
13. PATCH EXISTING WALLS AND FLOORS TO MATCH EXISTING WHERE NEW MECHANICAL UTILITIES SUCH AS PIPING, ATC WIRING AND TUBING, DUCTS, ETC. PENETRATES EXISTING WALLS AND FLOORS TO MATCH EXISTING WHERE EXISTING PIPING, WIRING, TUBING, DUCTS, ETC. ARE
BEING REMOVED AND PENETRATES EXISTING WALLS.
14. SANITARY PIPING BELOW SLAB SHALL BE MINIMUM OF 2 INCHES.
15. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF PLUMBING FIXTURES. DO NOT DIMENSION LOCATIONS FROM THESE DRAWINGS.
16. COORDINATE RISER LOCATIONS WITH STRUCTURAL BUILDING COMPONENTS.
17. SANITARY PIPING SHALL RUN AT 2% SLOPE MINIMUM UNLESS NOTED OTHERWISE, COORDINATE INSTALLATION OF PIPING WITH CONDITIONS
IN THE CEILINGS SPACE AND CRAWL SPACE BELOW.
18. CONDENSATE DRAIN PIPING SHALL RUN AT 2% SLOPE MINIMUM UNLESS NOTED OTHERWISE.
19. LOCATIONS OF DRAINS AND CONNECTIONS TO FIXTURES AND EQUIPMENT SHALL BE COORDINATED WITH THE FIXTURE PLAN, EQUIPMENT CUTS, AND MECHANICAL/ELECTRICAL PLANS. NO WORK SHALL BE INSTALLED UNTIL THE LOCATIONS HAVE BEEN VERIFIED.
20. PLUMBING FIXTURES SHALL BE CAULKED TO THE ADJOINING FLOOR OR WALL WITH CAULK COLOR AS SELECTED BY THE ARCHITECT.
21. WALL CLEANOUTS SHALL BE PROVIDED AT THE BASE OF EACH SANITARY RISER.
22. ROUTE DOMESTIC WATER PIPING, SPRINKLER PIPING, HVAC PIPING, GAS PIPING, ETC. IN PIPE CHASES AND FURRED OUT WALLS AND ABOVE
CEILINGS. NO PIPING SHALL BE EXPOSED UNLESS APPROVED BY THE ARCHITECT OR OWNER.
23. FIELD CHECK PREMISES PRIOR TO SUBMITTING BID TO BECOME ACQUAINTED WITH EXISTING CONDITIONS AND TO DETERMINE BEST MANNER FOR INSTALLATION, DETAILS OF PROPOSED DEPARTURES DUE TO ACTUAL FIELD CONDITIONS OR OTHER CAUSES SHALL BE SUBMITTED TO THE ARCHITECT FOR APPROVAL PRIOR TO FINAL INSTALLATION. NO EXTRAS SHALL BE PAID IN INSTANCES WHERE
DISCREPANCIES ARISE AND THE INSTALLER HAS FAILED TO VERIFY JOB SITE CONDITIONS.
1. NOTIFY THE OWNER IN WRITING AT LEAST FOURTEEN (14) DAYS IN ADVANCE OF ALL REQUIRED SHUTDOWNS OF WATER, SEWER, FIRE
PROTECTION, GAS, ELECTRICAL SERVICE, OR OTHER UTILITIES.
2. WHEN WORKING IN AND AROUND THE EXISTING BUILDING, CARE SHALL BE EXERCISED WITH REGARD TO PROTECTION OF EXISTING
STRUCTURE, AND MECHANICAL AND ELECTRICAL SERVICES WHICH SHALL REMAIN.
3. REPAIR, REPLACE, OR RESTORE TO THE SATISFACTION OF THE ARCHITECT ALL EXISTING WORK DAMAGED IN THE PERFORMANCE OF
DEMOLITION AND/OR NEW WORK.
4. THE EXISTING CONDITIONS (DUCTWORK, PIPING, EQUIPMENT, AND MATERIALS) SHOWN ON THE CONTRACT DOCUMENTS, ARE BASED ON INFORMATION OBTAINED FROM THE AVAILABLE RECORD DRAWINGS AND FIELDS SURVEYS AND SHALL BE CONSIDERED DIAGRAMMATIC.
THE CONTRACTOR SHALL FIELD VERIFY EXACT SIZES AND LOCATIONS OF ALL DUCTWORK, PIPING,EQUIPMENT, AND MATERIALS PRIOR TO
COMMENCING WITH NEW AND DEMOLITION WORK.
5. EXISTING MECHANICAL AND ELECTRICAL WORK INDICATED TO BE REMOVED: (PIPES, VALVES, DUCTS, ETC.) SHALL BE REMOVED TO A POINT BELOW THE FINISHED FLOORS OR BEHIND WALLS AND CAPPED. TERMINATION POINTS SHALL BE FAR ENOUGH BEHIND FINISHED SURFACES
TO ALLOW FOR THE INSTALLATION OF THE NORMAL THICKNESS OF FINISHED MATERIAL.
6. EXISTING PIPING NO LONGER REQUIRED TO REMAIN IN SERVICE SHALL BE DISCONTINUED AND REMOVED BACK TO EXISTING ASSOCIATED SERVICES MAIN UNLESS OTHERWISE INDICATED OR NOTED ON THE CONTRACT DRAWINGS. REMOVE EXISTING PIPE HANGERS, SUPPORTS, VALVES, ETC. EXISTING PIPING INDICATED OR REQUIRED TO REMAIN IN SERVICE OR IN PLACE SHALL BE CAPPED, PLUGGED OR OTHERWISE
SEALED. NO EXISTING PIPING SHALL BE LEFT OPEN ENDED.
7. DUCTWORK SHALL BE CAPPED WITH SIMILAR GAGE SHEET METAL. SECURE CAP(S) WITH SHEET METAL SCREWS AND SEAL WITH DUCT
SEALER. NO EXISTING DUCTWORK SHALL BE LEFT UNCAPPED.
8. PATCH TO MATCH EXISTING ALL NEW AND EXISTING OPENINGS I WALLS, CEILINGS AND FLOOR SURFACES DAMAGED OR CREATED BY DEMOLITION WORK. PATCHING SHALL MATCH EXISTING ADJACENT SURFACES AS TO THICKNESS, TEXTURES, MATERIALS AND COLOR. ALL PATCHING SHALL BE PERFORMED TO THE SATISFACTION OF THE ARCHITECT AND AT NO ADDITIONAL CONTRACT COST.
9. ALL DEMOLISHED EQUIPMENT SHALL BE OFFERED TO THE OWNER PRIOR TO DISPOSAL. EQUIPMENT RETAINED BY THE OWNER SHALL BE STORED WHERE DIRECTED BY THE OWNER. ANY EQUIPMENT THE OWNER DOES NOT WISH TO RETAIN SHALL BE DISPOSED OF, OFF SITE, BY THE CONTRACTOR.
GENERAL DEMOLITION NOTES
PLUMBING & HVAC DRAWING LIST
TITLENO.
DA
TE
IS
SU
E
PLUMBING & HVAC INDEX SHEETP001
PLUMBING & HVAC DEMOLITION AND NEW WORK PLANSP101
PLUMBING & HVAC SCHEDULE AND DETAILSP201
AREA DRAIN
ANCHOR
CLEAN OUT
GROUND CLEAN OUT
FLOOR CLEAN OUT
FUNNEL FLOOR DRAINS
FLOOR DRAIN
FLOOR SINK
ROOF OVERFLOW DRAIN
ROOF DRAIN
WALL CLEAN OUT
ACCESS PANEL
AQUASTAT
YARD CLEAN OUT
SINK DRAIN
SHOWER DRAIN
PIPE DRAIN
MANHOLE
CONCENTRIC REDUCER
ECCENTRIC REDUCER
GUIDE
DIRECTION & PITCH OF PIPE
GROUND HYDRANT
HOSE BIBB
WATER METER
PIPE DROPPING DOWN
PIPE TEE OFF BOTTOM
PIPE RISER FULL
PIPE RISER UP
PIPE ANCHOR
PIPE CAP
PIPE GUIDE
PIPE UNION - SCREWED OR FLANGED
PIPE STRAINER
DIRECTION & GRADE OF SLOPE
DIRECTION OF FLOW
OPEN SITE DRAIN
FILTER
PIPE VALVE IN RISE
ELECTRICALLY TRACED PIPING
PIPE EXPANSION JOINT
PIPE STRAINER WITH BLOW OFF VALVE
PRESSURE SWITCH
PRESSURE INDICATOR
GAS METER
PUMP
DIELECTRIC FITTING
PIPE COUPLING
WASHER DRAIN
SHEET NOTE
SHOCK ABSORBER
PIPE SHOCK ABSORBER
PIPE SHOCK ARRESTOR
CHECK VALVE
OS&Y MAIN SHUT-OFF VALVE
BALL VALVE
GAS COCK
PRESSURE REDUCING VALVE
AUTOMATIC GAS CONTROL VALVE
SOLENOID VALVE
FLOW SWITCH
FLOOR CONTROL VALVE
BACK FLOW PREVENTER VALVE
THERMOMETER - INDICATOR
AUTOMATIC TRAP PRIMER VALVE
MIXING VALVE
GATE VALVE
GLOBE VALVE
DIAPHRAGM VALVE
BUTTERFLY VALVE
2 WAY CONTROL VALVE
3 WAY CONTROL VALVE
RELIEF / SAFETY VALVE
CIRCUIT BALANCING VALVE
TEMPERATURE AND PRESSURE RELIEF VALVE (T&P)
SWING CHECK VALVE
BACK WATER VALVE
TEMPERATURE TRANSMITTER
THRUST BLOCK
BALANCING VALVE
HWRBA
DOUBLE CHECK VALVE ASSEMBLY
VALVE & VALVE 2
GAS PRESSURE REDUCING VALVE
WATER HAMMER ARRESTOR
EXISTING TO REMOVE
RAIN WATER
NATURAL GAS
GENERAL ABBREVIATIONS
(D) DEMOLISH
(E) EXISTING
(ER) EXISTING TO REMAIN
(F) REFURBISH
(M) PROVIDED BY MANUFACTURER
(N) NEW
(R) RELOCATE
(RE) RELOCATED EXISTING
A ANCHOR
ABV ABOVE
AC AIR COMPRESSOR OR ABOVE CEILING
ACFM ACTUAL CUBIC FEET PER MINUTE
AD AREA DRAIN OR ACCESS DOOR
ADJ ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AFS AUTOMATIC FLUSH SYSTEM
AHU AIR HANDLING UNIT
AI ANALOG INPUT
AMB AMBIENT
AO ANALOG OUTPUT
AP ACCESS PANEL
APD AIR PRESSURE DROP
ARCH ARCHITECTURAL
ASC APPLICATION SPECIFIC CONTROLLER
ATC AUTOMATIC TEMPERATURE CONTROL
ATP AUTOMATIC TRAP PRIMER
AVG AVERAGE
AW ACID WASTE
AWT AVERAGE WATER TEMPERATURE
AV ACID VENT
AVTR ACID VENT THROUGH ROOF
B BOILER
BA BREATHING AIR
BAS BUILDING AUTOMATION SYSTEM
BCA BOTTLED COMPRESSED AIR
BF BELOW FLOOR
BFP BACK FLOW PREVENTER OR BOILER FEED PUMP
BHP BRAKE HORSEPOWER OR BOILER HORSEPOWER
BIW BIO-WASTE
BIWV BIO-WASTE VENT
BLDG BUILDING
BLW BELOW
BO BINARY OUTPUT
BOD BASIS OF DESIGN
BOP BOTTOM OF PIPE
BOT BOTTOM
BWV BACKWATER VALVE
CA COMPRESSED AIR
CAP CAPACITY
CBV CIRCUIT BALANCING VALVE
CD CONDENSATE
CF CHEMICAL FEED
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CLG CEILING
CO CLEAN OUT
COL COLUMN
COMB COMBINED SANITARY & STORM
CONC CONCRETE OR CONCENTRATION
CONT CONTINUATION
CONT'D CONTINUED
CTS COUNTERTOP SINK
CVS CONTROL VALVE STATION
CW DOMESTIC COLD WATER
D DROP
DC DIRECT CURRENT
DCVA DOUBLE CHECK VALVE ASSEMBLY
DDC DIRECT DIGITAL CONTROL
DET DETAIL
DIA DIAMETER
DISC DISCONNECT
DISCH DISCHARGE
DI DEIONIZED OR DIGITAL INPUT
DN DOWN
DO DIGITAL OUTPUT
DOM DOMESTIC
DR DRAIN
DS DISCONNECT SWITCH
DWG DRAWING
EA EACH
EFF EFFICIENCY
EJ EXPANSION JOINT
ELEC ELECTRIC
ELEV ELEVATION
EMER EMERGENCY
ENT ENTERING
ET ELECTRICALLY TRACED PIPING
EQPM EQUIPMENT
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
EWT ENTERING WATER TEMPERATURE
EXH EXHAUST
EXIST EXISTING
EXT EXTERNAL
F FILTER
FA FROM ABOVE
FAI FRESH AIR INLET
FB FROM BELOW
FCO FLOOR CLEAN OUT
FCV FLOOR CONTROL VALVE
FD FLOOR DRAIN
FFD FUNNEL FLOOR DRAIN
FIN FINAL
FLA FULL LOAD AMPS
FLEX FLEXIBLE
FLR FLOOR
FLTR FILTER
FM FLOW METERING DEVICE
FOB FLAT ON BOTTOM
FOT FLAT ON TOP
FP FIRE PROTECTION
FPM FEET PER MINUTE
FPS FEET PER SECOND
FS FLOOR SINK OR FLOW SWITCH
FSV FOOD SERVICE VENDOR
FT FOOT OR FEET
FU FIXTURE UNIT
FUT FUTURE
FW FILTERED WATER
G GAS
GCO GROUND CLEAN OUT
GH GROUND HYDRANT
GI GREASE INTERCEPTOR
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
H HYDRANT
HB HOSE BIBB
HD HUB DRAIN
HG MERCURY
HO HUB OUTLET
HP HORSEPOWER
HTG HEATING
HVAC HEATING, VENTILATION, AND AIR CONDITIONING
HW DOMESTIC HOT WATER (110° F)
HWG HOT WATER GENERATOR
HWH HOT WATER HEATER
HWR DOMESTIC HOT WATER RETURN (110° F)
HWRP HOT WATER RE-CIRCULATING PUMP
HX HEAT EXCHANGER
ID INSIDE DIAMETER
IN INCHES
INT INITIAL
INV INVERT
INV EL INVERT ELEVATION
IW INDIRECT WASTE
KW KILOWATT
LB POUND
LCW LABORATORY COLD WATER
LHW LABORATORY HOT WATER
LHWR LABORATORY HOT WATER RETURN
LD LINEAR DIFFUSER
LDB LEAVING DRY BULB
LF LINEAR FOOT
LG LINEAR GRILLE
LP LIQUID PROPANE
LRA LOCKED ROTOR AMPS
LS LABORATORY SINK
LVG LEAVING
LWCO LOW WATER CUTOFF
MAX MAXIMUM
MBH 1000 BTU PER HOUR
MCC MOTOR CONTROL CENTER
MECH MECHANICAL
MER MECHANICAL EQUIPMENT ROOM
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM OR MINUTE
MOCP MAXIMUM OVERCURRENT PROTECTION
MODU MODULATING
MR MOP RECEPTOR
MV MIXING VALVE
MXB MODULATING MIXING BOX
N NEW
NC NORMALLY CLOSED
NG NATURAL GAS
NIC NOT IN CONTRACT
NO NORMALLY OPEN OR NUMBER
NPW NON-POTABLE WATER
NTS NOT TO SCALE
OA OUTSIDE AIR
OAE OUTSIDE AIR ENTHALPY
OAH OUTSIDE AIR HUMIDITY
OAI OUTSIDE AIR INTAKE
OAT OUTSIDE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .