3-20260119 Jackson Twp Maintenance Arch.pdf
PDF 5 MB Posted
- Attached to
- Little Creek Park Maintenance Building
- Solicitation number
- Not on record
- Issued by
- York County, Pennsylvania
About this file
This is an architectural drawing set and construction bidding document for the Little Creek Park Maintenance Building project in Jackson Township, York County, Pennsylvania. The project involves new construction of a 3,600 square foot maintenance building located at 1657 Hanover Road, York, PA 17362. The design team includes Mula Group (Architecture), Entegra (Mechanical, Electrical, Plumbing), and C.S. Davidson, Inc. (Structural and Civil). The scope of work encompasses architectural design, structural support, HVAC systems, plumbing installation (hot/cold water lines and sanitary sewer), electrical service with outlets and lighting, fire alarm systems, and site work including grading and utilities. Sealed bids are due online via the PennBid Program by 10:00 A.M. on Thursday, February 26, 2026. Four separate contracts are available for bidding: General Construction, Mechanical, Electrical, and Plumbing. The project is subject to Pennsylvania Prevailing Wage Act requirements, and the contract time is one hundred fifty (150) calendar days from commencement.
A bid bond or certified check equal to 10% of the maximum bid amount, made payable to Jackson Township, is required from each bidder. Bidders must provide evidence of qualifications to perform the work. The construction documents comply with the 2018 International Building Code, Pennsylvania Uniform Construction Code, and include detailed accessibility requirements per ANSI A117.1 (2009). The drawing set was issued for permit on December 17, 2025, and for bidding on January 19, 2026. Jackson Township reserves the right to accept any bid or reject all bids, with contract awards to be made at a regularly scheduled township meeting. No site visit or bidders conference is referenced in the available documentation.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CO
NT
AC
T
IN
FO
RM
AT
IO
N:
DE
SI
GN
MU
LA
G
RO
UP
5 C
OT
TA
GE
H
ILL
R
OA
D
YO
RK
P
A
7.8
.01
H
AN
OV
ER
R
OA
D
YO
RK
, P
A, LI
TT
LE
C
RE
EK
P
AR
K
MA
IN
TE
NA
NC
E
BU
IL
DI
NG
CO
VE
R
SH
EE
T
A-000
NE
W
C
ON
ST
RU
CT
IO
N
FO
R:
BL
AI
R
LE
HM
AN
BL
EH
MA
N@
TH
EM
UL
AG
RO
UP
.C
OM
-1
M
UL
A
GR
OU
P
CODE COMPLIANCE
PENNSYLVANIA UNIFORM CONSTRUCTION CODE
2018 INTERNATIONAL BUILDING CODE EXCEPT AS LISTED BELOW:
2018 INTERNATIONAL BUILDING CODE, CHAPTER 11 & APPENDIX E
2018 INTERNATIONAL PLUMBING CODE
2018 INTERNATIONAL MECHANICAL
2018 INTERNATIONAL FUEL GAS CODE
2017 NATIONAL ELECTRIC CODE
2018 INTERNATIONAL FIRE CODE
2018 INTERNATIONAL ENERGY CONSERVATION CODE
2018 NFPA 101 LIFE SAFETY CODE
2009 ICC A117.1
THE DRAWINGS CONTAINED WITHIN THIS SET ARE SUBMITTED
IN COMPLIANCE WITH THE FOLLOWING CODES:
DRAWING SUBMITTAL SCHEDULE
CI
VI
L
INCLUDED
DEFFERED
NOT APPLICABLE
AR
CH
IT
EC
TU
RA
L
ST
RU
CT
UR
AL
HV
AC
PL
UM
BI
NG
EL
EC
TR
IC
AL
FI
RE
A
LA
RM
SP
RI
NK
LE
RS
DI
SC
IP
LI
NE
SCOPE OF WORK
ARCHITECTURAL:
ARCHITECTURAL
DESIGN FOR A 3,600
SQ.FT. MAINTENANCE
BUILDING
STRUCTURAL:
PROVIDE STRUCTURAL
DESIGN TO SUPPORT 3,600
SQ.FT. MAINTENANCE
BUILDING
HVAC:
PROVIDE NEW MECHANICAL
SERVICE & DISTRIBUTION
TO SUPPORT PROPOSED
MAINTENANCE BUILDING
PLUMBING:
PROVIDE HOT & COLD WATER
LINES AND SANITARY SEWER FOR
PROPOSED MAINTENANCE
BUILDING. PROVIDE NEW GAS LINE
TO SUPPORT MECHANICAL
SERVICE
ELECTRICAL:
PROVIDE ELECTRICAL
SERVICE FOR PROPOSED
MAINTENANCE BUILDING
INCLUSIVE OF OUTLETS,
LIGHT FIXTURES, AND SITE
LIGHTING
NEW CONSTRUCTION FOR:
LITTLE CREEK PARK MAINTENANCE BUILDING
1657 HANOVER ROAD
YORK, PA, 17362
JACKSON TOWNSHIP, YORK COUNTY, PENNSYLVANIA
FIRE ALARM
NO SCOPE OF WORK
SITE LOCATION
PROJECT TEAM
ARCHITECTURAL:
MULA GROUP
325 COTTAGE HILL ROAD
YORK, PA 17401
717.880.0131
CONTACT: BLAIR LEHMAN
OWNER:
JACKSON TOWNSHIP
439 ROTHS CHURCH ROAD
SPRING GROVE, PA 17362
717.225.5661
CONTACT: FLORENCE FORD
MEP:
ENTEGRA
34 FARM LANE
HEGINS, PA, 17938
301.520.7931
CONTACT: JASON KRAMER, PE, CEM, LEED AP
NORTH ARROW
N
N
PLAN PROJECT
SITE
STRUCTURAL:
C.S. DAVIDSON, INC.
38 NORTH DUKE STREET
YORK, PA, 17401
717.846.4805
CONTACT: SONDRA LAUB, P.E.
CIVIL:
C.S. DAVIDSON, INC.
38 NORTH DUKE STREET
YORK, PA, 17401
717.846.4805
CONTACT: SONDRA LAUB, P.E.
GOOGLE 2025
DRAWING INDEX
SHEET NUMBER SHEET NAME
C1 COVER SHEET
C2 EXISTING CONDITIONS & DEMOLITION PLAN
C3 PROPOSED SITE, GRADING, & UTILITY PLAN
C4 STORM SEWER PROFILE
C5 CONSTRUCTION DETALS
CI
VI
L
A-000 COVER SHEET
A-001 ANSI A117.1 (2009) ACCESSIBILITY DETAILS
A-002 ANSI A117.1 (2009) ACCESSIBILITY DETAILS
A-003 ANSI A117.1 (2009) ACCESSIBILITY DETAILS
A-004 STANDARD PARTITIONS, NOTES, & ABBREVIATIONS
A-081 LIFE SAFETY PLAN
A-101 FIRST FLOOR & REFLECTED CEILING PLANS
A-102 ROOF PLAN
A-201 EXTERIOR ELEVATIONS & BUILDING SECTIONS
A-301 WALL SECTIONS
A-401 DETAILS
A-501 INTERIOR ELEVATIONS
A-601 SCHEDULES, LEGENDS, & DETAILS
AR
CH
IT
EC
TU
RA
L
S-001 GENERAL NOTES
S-002 DIAGRAMS & HEADER PLANS
S-101 STRUCTURAL PLANS
S-201 FOUNDATION DETAILS
S-301 WOOD FRAMING DETAILS
ST
RU
CT
UR
AL
M0.1 MECHANICAL INFORMATION SHEET
M2.1 MECHANICAL FLOOR PLAN
M6.1 MECHANICAL SCHEDULES & DETAILS
M9.1 MECHANICAL SPECIFICATIONS
ME
CH
AN
IC
AL
P0.1 PLUMBING INFORMATION SHEET
P0.3 PLUMBING FLOOR PLANS
P9.1 PLUMBING SCHEDULES & SPECIFICATIONS
PL
UM
BI
NG
E0.1 ELECTRICAL INFORMATION SHEET
E0.2 ELECTRICAL SYMBOLS SHEET
E2.1 ELECTRICAL FLOOR PLAN - POWER
E3.1 ELECTRICAL FLOOR PLAN - LIGHTING
E6.1 ELECTRICAL SCHEDULES & DIAGRAMS
E8.1 ELECTRICAL DETAILS
E9.1 ELECTRICAL SPECIFICATIONS
EL
EC
TR
IC
AL
RE
CO
RD
O
F
IS
SU
E
DA
TE
IS
SU
E
RE
V
.12 .17
IS
SU
ED
F
OR
P
ER
MI
T
.01
.19
IS
SU
ED
F
OR
B
ID
DI
NG
This Drawing Produced by the U.S. Access Board
This Drawing Produced by the U.S. Access Board
302.1 GENERAL. FLOOR SURFACES SHALL BE STABLE, FIRM, AND SLIP RESISTANT, AND SHALL
COMPLY WITH SECTION 303.
302.2 CARPET. CARPET OR CARPET TILE SHALL BE SECURELY ATTACHED AND SHALL HAVE A
FIRM CUSHION, PAD, OR BACKING OR NO CUSHION OR PAD. CARPET OR CARPET TILE SHALL
HAVE A LEVEL LOOP, TEXTURED LOOP, LEVEL CUT PILE, OR LEVEL CUT/UNCUT PILE TEXTURE.
PILE HEIGHT SHALL BE 1/2 INCH MAXIMUM. EXPOSED EDGES OF CARPET SHALL BE FASTENED TO
FLOOR SURFACES AND SHALL HAVE TRIM ON THE ENTIRE LENGTH OF THE EXPOSED EDGE.
CARPET EDGE TRIM SHALL COMPLY WITH 303.
FIGURE 302.2
CARPET ON FLOOR SURFACES
303.2 VERTICAL. CHANGES IN LEVEL OF 1/4 INCH (6.4 MM) MAXIMUM IN HEIGHT SHALL BE
PERMITTED TO BE VERTICAL.
303.3 BEVELED. CHANGES IN LEVEL GREATER THAN 1/4 INCH (6.4 MM) IN HEIGHT AND NOT MORE THAN 1/2 INCH (13 MM) MAXIMUM IN HEIGHT SHALL BE BEVELED WITH A SLOPE NOT STEEPER THAN 1:2.
303.4 RAMPED. CHANGES IN LEVEL GREATER THAN 1/4 INCH (6.4 MM) IN HEIGHT AND NOT MORE THAN 1/2 INCH (13 MM) MAXIMUM IN HEIGHT SHALL BE BEVELED WITH A SLOPE NOT STEEPER THAN 1:2.
FIGURE 303.2
VERTICAL CHANGE IN LEVEL
FIGURE 303.3
BEVELED CHANGE IN LEVEL
1/2 MAX
1/4 MAX
6.4
1/4
6.4
1/4
6.4
1/2
304.2 FLOOR OR GROUND SURFACE. FLOOR SURFACES OF A TURNING SPACE SHALL COMPLY WITH SECTION
302. CHANGES IN LEVEL ARE NOT PERMITTED WITHIN THE TURNING SPACE
EXCEPTION: SLOPES NOT STEEPER THAN 1:48 SHALL BE PERMITTED.
304.3 SIZE. TURNING SPACES SHALL COMPLY WITH SECTION 304.3.1 OR 304.3.2.
60" MIN.
60" MIN.
" M
IN
12" MIN. 36" MIN. 12" MIN.
" M
IN
" M
IN
FIGURE 304.3
SIZE OF WHEELCHAIR TURNING SPACE
(B) T-SHAPED
(A) CIRCULAR
305.2 FLOOR SURFACE. FLOOR SURFACES OF A CLEAR FLOOR SPACE SHALL COMPLY WITH SECTION 302.
CHANGES IN LEVEL ARE NOT PERMITTED WITHIN THE CLEAR FLOOR SPACE.
EXCEPTIONS: SLOPES NOT STEEPER THAN 1:48 SHALL BE PERMITTED.
305.3 SIZE. THE CLEAR FLOOR SPACE SHALL BE 48 INCHES (1220 MM) MINIMUM LENGTH AND 30 INCHES (760
MM) MINIMUM WIDTH.
305.5 POSITION. UNLESS OTHERWISE SPECIFIED, THE CLEAR FLOOR SPACE SHALL BE POSITIONED FOR
EITHER FORWARD OR PARALLEL APPROACH TO AN ELEMENT.
FIGURE 305.3
SIZE OF CLEAR GROUND SPACE
308.2 FORWARD REACH.
308.2.1 UNOBSTRUCTED. WHERE A FORWARD REACH IS UNOBSTRUCTED, THE HIGH FORWARD REACH SHALL BE 48" MAXIMUM AND THE LOW FORWARD REACH SHALL BE 15" MINIMUM ABOVE THE FLOOR OR
GROUND.
308.2.2 OBSTRUCTED HIGH REACH. WHERE A HIGH FORWARD REACH IS OVER AN OBSTRUCTION, THE CLEAR FLOOR SPACE COMPLYING WITH SECTION 305 SHALL EXTEND BENEATH THE ELEMENT FOR A DISTANCE NOT LESS THAN THE REQUIRED REACH DEPTH OVER THE OBSTRUCTION. THE HIGH FORWARD REACH SHALL BE 48 INCHES (1220 MM) MAXIMUM ABOVE THE FLOOR WHERE THE REACH DEPTH IS 20 INCHES (510 MM) MAXIMUM. WHERE THE REACH DEPTH EXCEEDS 20 INCHES (510 MM), THE HIGH FORWARD REACH SHALL BE 44 INCHES (1120 MM) MAXIMUM ABOVE THE FLOOR, AND THE REACH DEPTH
SHALL BE 25 INCHES (635 MM) MAXIMUM.
308.3 SIDE REACH
308.3.1 UNOBSTRUCTED. WHERE A CLEAR FLOOR SPACE COMPLYING WITH SECTION 305 ALLOWS A PARALLEL APPROACH TO AN ELEMENT AND THE EDGE OF THE CLEAR FLOOR SPACE IS 10 INCHES (255 MM) MAXIMUM FROM THE ELEMENT, THE HIGH SIDE REACH SHALL BE 48 INCHES (1220 MM) MAXIMUM AND
THE LOW SIDE REACH SHALL BE 15 INCHES (380 MM) MINIMUM ABOVE THE FLOOR.
EXCEPTION. EXISTING ELEMENTS THAT ARE NOT ALTERED SHALL BE PERMITTED AT 54 INCHES
(1370 MM) MAXIMUM ABOVE THE FLOOR.
308.3.2 OBSTRUCTED HIGH REACH. WHERE A CLEAR FLOOR SPACE COMPLYING WITH SECTION 305 ALLOWS A PARALLEL APPROACH TO AN ELEMENT AND THE HIGH SIDE REACH IS OVER AN OBSTRUCTION, THE HEIGHT OF THE OBSTRUCTION SHALL BE 34 INCHES (865 MM) MAXIMUM ABOVE THE FLOOR AND THE DEPTH OF THE OBSTRUCTION SHALL BE 24 INCHES (610 MM) MAXIMUM. THE HIGH SIDE REACH SHALL BE 48 INCHES (1220 MM) MAXIMUM ABOVE THE FLOOR FOR A REACH DEPTH OF 10 INCHES (255 MM).
FIGURE 308.2.2
OBSTRUCTED HIGH FORWARD REACH
FIGURE 308.2.1
UNOBSTRUCTED FORWARD REACH
FIGURE 308.2.2
OBSTRUCTED HIGH FORWARD REACH
FIGURE 308.2.1
UNOBSTRUCTED FORWARD REACH
SEGMENT LENGTH
LESS THAN OR EQUAL TO 24"
GREATER THAN 34"
NOTE:
MINIMUM SEGMENT WIDTH
32"(1)
36"
(1) CONSECUTIVE SEGMENTS OF 32" WIDE MUST BE SEPARATED BY A ROUTE SEGMENT 48" LONG
MINIMUM AND 36" WIDE MINIMUM.
TABLE 403.5
CLEAR WIDTH OF AN ACCESSIBLE ROUTE
FIGURE 403.5
CLEAR WIDTH OF AN ACCESSIBLE ROUTE
404.1 GENERAL. DOORS AND DOORWAYS THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH SECTION 404.
404.2 MANUAL DOORS. MANUAL DOORS AND DOORWAYS, AND MANUAL GATES, INCLUDING TICKET GATES, SHALL COMPLY WITH SECTION 404.2.
EXCEPTION: DOORS, DOORWAYS, AND GATES DESIGNED TO BE OPERATED ONLY BY SECURITY PERSONNEL SHALL NOT BE REQUIRED TO COMPLY WITH SECTIONS 404.2.6, 404.2.8.
404.2.1 DOUBLE-LEAF DOORS AND GATES. AT LEAST ONE OF THE ACTIVE LEAVES OF DOORWAYS WITH TWO LEAVES SHALL COMPLY WITH SECTIONS 404.2.2 AND 404.2.3.
404.2.2 CLEAR WIDTH. DOORWAYS SHALL HAVE A CLEAR OPENING WIDTH OF 32 INCHES (815 MM) MINIMUM. CLEAR OPENING WIDTH OF DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF DOOR AND STOP, WITH THE DOOR OPEN 90 DEGREES. OPENINGS MORE THAN 24 INCHES (610 MM) IN DEPTH AT DOORS AND DOORWAYS WITHOUT DOORS SHALL PROVIDE A CLEAR OPENING WIDTH OF 36 INCHES (915 MM) MINIMUM. THERE SHALL BE NO PROJECTIONS INTO THE CLEAR OPENING WIDTH LOWER THAN 34 INCHES (865 MM) ABOVE THE FLOOR. PROJECTIONS INTO THE CLEAR OPENING WIDTH BETWEEN 34 INCHES (865 MM) AND 80 INCHES (2030 MM) ABOVE THE FLOOR SHALL NOT
EXCEED 4 INCHES (100 MM).
EXCEPTIONS:
1. DOOR CLOSERS AND DOOR STOPS SHALL BE PERMITTED TO BE 78 INCHES (1980 MM) MINIMUM ABOVE THE FLOOR.
2. IN ALTERATIONS, A PROJECTION OF 5/8 INCH (16 MM) MAXIMUM INTO THE REQUIRED CLEAR OPENING WIDTH SHALL BE PERMITTED FOR THE LATCH SIDE STOP.
404.2.3 MANEUVERING CLEARANCES. MINIMUM MANEUVERING CLEARANCES AT DOORS SHALL COMPLY WITH SECTION 404.2.3 AND SHALL INCLUDE THE FULL CLEAR OPENING WIDTH OF THE DOORWAY. REQUIRED DOOR MANEUVERING
CLEARANCES SHALL NOT INCLUDE KNEE AND TOE CLEARANCE.
404.2.3.1 FLOOR SURFACE. FLOOR SURFACE WITHIN THE MANEUVERING CLEARANCES SHALL HAVE A SLOPE NOT STEEPER THAN 1:48 AND SHALL COMPLY WITH SECTION 302.
404.2.3.2 SWINGING DOORS. SWINGING DOORS SHALL HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE 404.2.3.2.
404.2.3.3 SLIDING AND FOLDING DOORS. SLIDING DOORS AND FOLDING DOORS SHALL HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE 404.2.3.3.
404.2.3.4 DOORWAYS WITHOUT DOORS. DOORWAYS WITHOUT DOORS THAT ARE LESS THAN 36 INCHES (915 MM) IN WIDTH SHALL HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE 404.2.3.4
404.2.3.5 RECESSED DOORS. WHERE ANY OBSTRUCTION WITHIN 18 INCHES (455 MM) OF THE LATCH SIDE OF A DOORWAY PROJECTS MORE THAN 8 INCHES (205 MM) BEYOND THE FACE OF THE DOOR, MEASURED PERPENDICULAR TO
THE FACE OF THE DOOR, MANEUVERING CLEARANCES FOR A FORWARD APPROACH SHALL BE PROVIDED.
404.2.4 THRESHOLDS. IF PROVIDED, THRESHOLDS AT DOORWAYS SHALL BE 1/2 INCH (13 MM) MAXIMUM IN HEIGHT. RAISED THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS SHALL COMPLY WITH SECTIONS 302 AND 303.
EXCEPTION: AN EXISTING OR ALTERED THRESHOLD SHALL BE PERMITTED TO BE 3/4 INCH (19 MM) MAXIMUM IN HEIGHT PROVIDED THAT THE THRESHOLD HAS A BEVELED EDGE ON EACH SIDE WITH A MAXIMUM SLOPE OF 1:2 FOR THE
HEIGHT EXCEEDING 1/4 INCH (6.4 MM).
404.2.5 TWO DOORS IN A SERIES. DISTANCE BETWEEN TWO HINGED OR PIVOTED DOORS IN SERIES SHALL BE 48 INCHES (1220 MM) MINIMUM PLUS THE WIDTH OF ANY DOOR SWINGING INTO THE SPACE. THE SPACE BETWEEN THE DOORS
SHALL PROVIDE A TURNING SPACE COMPLYING WITH SECTION 304.
404.2.6 DOOR HARDWARE. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34 INCHES (865 MM) MINIMUM AND 48 INCHES (1220 MM) MAXIMUM ABOVE THE FLOOR. WHERE SLIDING DOORS ARE IN THE FULLY OPEN POSITION, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES.
EXCEPTION: LOCKS USED ONLY FOR SECURITY PURPOSES AND NOT USED FOR NORMAL OPERATION SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 404.2.6.
FIGURE 404.2.2
CLEAR WIDTH OF DOORWAYS
TABLE 404.2.3.2 -- MANEUVERING CLEARANCES OF MANUAL
SWINGING DOORS
TYPE OF USE
APPROACH
DIRECTION
FROM FRONT
FROM HINGE
FROM LATCH
NOTES:
PULL
PUSH
FROM HINGE
FROM LATCH
FROM FRONT
PUSH
PUSH
PULL
PULL
DOOR SIDE PERPENDICULAR TO DOOR PARALLEL TO DOORWAY
(BEYOND LATCH UNLESS NOTED)
60"
48"
60" 54"
42"
48"
42" 24"
24"
22"
36" 42"
0"
18"
(3)(4)(1)
(2)
(2)
(1) ADD 6 INCHES IF CLOSER AND LATCH PROVIDED
(2) ADD 6 INCHES IF CLOSER PROVIDED
(3) ADD 12 INCHES BEYOND LATCH IF CLOSER AND LATCH PROVIDED
(4) BEYOND HINGE SIDE
FIGURE 404.2.3.2
MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS
MINIMUM CLEARANCES
APPROACH DIRECTION
FROM FRONT
FROM HINGE SIDE
FROM LATCH SIDE
NOTES:
MINIMUM CLEARANCES
PERPENDICULAR TO DOOR PARALLEL TO DOOR
48"
42"
42"
0" 22"
24" (1)
(1)
(1) BEYOND POCKET OR HINGE SIDE
TABLE 404.2.3.3 -- MANEUVERING CLEARANCES FOR SLIDING
AND FOLDING DOORS
FIGURE 404.2.3.3 -- MANEUVERING CLEARANCES FOR SLIDING
AND FOLDING DOORS
TABLE 404.2.3.4 -- MANEUVERING CLEARANCES FOR
DOORWAYS WITHOUT DOORS
APPROACH DIRECTION
FROM FRONT
FROM SIDE
MINIMUM CLEARANCES
PERPENDICULAR TO DOOR
48"
42"
NOTES:
(1) MANEUVERING SPACE SHALL INCLUDE FULL WIDTH OF DOORWAY.
(1)
FIGURE 404.2.5
TWO DOORS IN A SERIES
60" MIN.
DO
OR
W
ID
TH
" M
IN
DO
OR
W
ID
TH
" M
IN
DO
OR
W
ID
TH
60" MIN.
" M
IN
(C)
(A) (B)
504.2 TREADS AND RISERS. ALL STEPS ON A FLIGHT OF STAIRS SHALL HAVE UNIFORM RISER HEIGHTS AND UNIFORM TREAD DEPTH. RISERS SHALL BE 4" HIGH MINIMUM AND 7" MAXIMUM. TREADS SHALL BE 11" DEEP MINIMUM, MEASURED FROM RISER
TO RISER. (FIG. 504.2)
504.3 OPEN RISERS. OPEN RISERS SHALL NOT BE PERMITTED.
504.4 TREAD SURFACE. STAIR TREADS SHALL COMPLY WITH SECTION 302 AND HAVE A SLOPE NOT STEEPER THAN 1:48.
504.5 NOSINGS. THE RADIUS OF CURVATURE AT THE LEADING EDGE OF THE TREAD SHALL BE 1/2" MAXIMUM. NOSINGS THAT PROJECT BEYOND RISERS SHALL HAVE THE UNDERSIDE OF THE LEADING EDGE CURVED OR BEVELED. RISERS SHALL BE PERMITTED TO SLOPE UNDER THE TREAD AT AN ANGLE OF 30 MAXIMUM FROM VERTICAL. THE PERMITTED PROJECTION OF
THE NOSING SHALL BE 1-1/2" MAXIMUM BEYOND THE TREAD BELOW.
504.6 HANDRAILS. STAIRS SHALL HAVE HANDRAILS COMPLYING WITH SECTION 505.
504.5.1 VISUAL CONTRAST. THE LEADING 2 INCHES (51 MM) OF THE TREAD SHALL HAVE VISUAL CONTRAST OF DARK-ON-LIGHT
OR LIGHT-ON-DARK FROM THE REMAINDER OF THE TREAD.
FIGURE 504.2 TREADS AND RISERS FOR ACCESSIBLE STAIRWAYS
FIGURE 504.5 STAIR NOSINGS
505.2 LOCATION. HANDRAILS SHALL BE PROVIDED ON BOTH SIDES OF STAIRS AND RAMPS.
EXCEPTIONS:
1. IN ASSEMBLY SEATING AREAS, HANDRAILS SHALL NOT BE REQUIRED ON BOTH SIDES ALONG AISLE
STAIRS, PROVIDED WITH A HANDRAIL EITHER AT THE SIDE OR WITHIN THE AISLE.
2. IN ASSEMBLY SEATING AREAS, HANDRAILS SHALL NOT BE REQUIRED ON THE SIDES OF RAMPED AISLES
SERVING SEATS.
505.3 CONTINUITY. HANDRAILS SHALL BE CONTINUOUS WITHIN THE FULL LENGTH OF EACH STAIR FLIGHT OR RAMP RUN. INSIDE HANDRAILS ON SWITCHBACK OR DOGLEG STAIRS OR RAMPS SHALL BE CONTINUOUS BETWEEN FLIGHTS OR RUNS. OTHER
HANDRAILS SHALL COMPLY WITH SECTIONS 505.10 AND 307.
EXCEPTIONS: HANDRAILS SHALL NOT BE REQUIRED TO BE CONTINUOUS IN AISLES SERVING SEATING WHERE HANDRAILS ARE DISCONTINUOUS TO PROVIDE ACCESS TO SEATING AND TO PERMIT CROSSOVERS WITHIN THE
AISLES.
505.4 HEIGHT. TOP OF GRIPPING SURFACES OF HANDRAILS SHALL BE 34" MINIMUM AND 38" MAXIMUM VERTICALLY ABOVE STAIR NOSINGS AND RAMP SURFACES. HANDRAILS SHALL BE AT A CONSISTENT HEIGHT ABOVE STAIR NOSINGS AND RAMP
SURFACES.
505.5 CLEARANCE. CLEAR SPACE BETWEEN HANDRAIL AND WALL SHALL BE 1-1/2" MINIMUM.
505.6 GRIPPING SURFACE. GRIPPING SURFACES SHALL BE CONTINUOUS, WITHOUT INTERRUPTION BY NEWELL POSTS, OR
OTHER CONSTRUCTION ELEMENTS OR OBSTRUCTIONS.
505.7 CROSS SECTION. HANDRAILS SHALL HAVE A CIRCULAR CROSS-SECTION WITH AN OUTSIDE DIAMETER OF 1-1/4" MINIMUM AND 2" MAXIMUM, OR SHALL PROVIDE EQUIVALENT GRASP ABILITY COMPLYING WITH SECTION 505.7.1 OR 505.7.2.
505.7.1 CIRCULAR CROSS SECTION. HANDRAILS WITH A CIRCULAR CROSS SECTION SHALL HAVE AN OUTSIDE
DIAMETER OF 1-1/4 INCHES (32 MM) MINIMUM AND 2 INCHES (51 MM) MAXIMUM.
505.7.2 NON-CIRCULAR CROSS SECTION. HANDRAILS WITH OTHER SHAPES SHALL BE PERMITTED PROVIDED THEY HAVE A PERIMETER DIMENSION OF 4" MINIMUM AND 6-1/2" MAXIMUM, AND PROVIDED THEIR LARGEST CROSS-SECTION
DIMENSION IS 2-1/4" MAXIMUM.
505.10.1 TOP AND BOTTOM EXTENSIONS AT RAMPS. RAMP HANDRAILS SHALL EXTEND HORIZONTALLY 12" MINIMUM BEYOND THE TOP AND BOTTOM OF RAMP RUNS. EXTENSION SHALL RETURN TO A WALL, GUARD, OR THE WALKING SURFACE, OR SHALL
BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT RAMP RUN.
505.10.2 TOP EXTENSIONS AT STAIRS. AT THE TOP OF A STAIR FLIGHT, HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE LANDING FOR 12" MINIMUM, BEGINNING DIRECTLY ABOVE THE FIRST RISER NOSING. SUCH EXTENSION SHALL RETURN TO A WALL, GUARD, OR THE WALKING SURFACE, OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT STAIR FLIGHT.
505.10.3 BOTTOM EXTENSION AT STAIRS. AT THE BOTTOM OF A STAIR FLIGHT, HANDRAILS SHALL EXTEND AT THE SLOPE OF THE STAIR FLIGHT FOR A HORIZONTAL DISTANCE EQUAL TO ONE TREAD DEPTH BEYOND THE BOTTOM TREAD NOSING.
EXTENSIONS SHALL RETURN TO A WALL, GUARD, OR THE LANDING SURFACE, OR SHALL BE CONTINUOUS TO THE HANDRAIL OF
AN ADJACENT STAIR FLIGHT.
(B) CURVED NOSING (C) BEVELED RISER
(D) ANGLED RISER(A) VERTICAL RISER
CURVED BEVELED
30* MAX
4" TO 6-1/4"
PERIMETER
FIGURE 505.4 HANDRAIL HEIGHT FIGURE 505.5
HANDRAIL CLEARANCE
(A)
STAIRS
(B)
STAIRS
(A)
CIRCULAR
(B)
NON CIRCULAR
(C)
NON CIRCULAR
FIGURE 505.7 HANDRAIL CROSS SECTION
FIGURE 505.10.1
TOP AND BOTTOM HANDRAIL EXTENSIONS AT RAMPS
FIGURE 505.10.2
TOP HANDRAIL EXTENSIONS AT STAIRS
FIGURE 505.10.3
BOTTOM HANDRAIL EXTENSIONS AT STAIRS
10" MAX
" M
AX
" M
AX
" M
AX
<10-24" MAX
" M
AX
10" MAX
" M
IN
" M
AX
" M
AX
20" MAX. >20-25" MAX.
" M
AX
" M
IN
" M
AX
48" MIN.
" M
IN
" M
IN
" M
IN
24" MAX 48" MIN. 24" MIN.
" M
IN
" M
IN
1-1/2" MAX1-1/2" MAX
(C) STOP OR LATCH APPROACH
(B) POCKET OR HINGE APPROACH
(A) FRONT APPROACH
" T
O
" T
O
1-1/2" MIN.
1- 1/2
" M
IN
2-1/4" MAX.
12" MIN.
12" MIN.
12" MIN.
12" MIN. X
X
4"
7"
11" MIN.
24" MIN.
" M
IN
22" MIN.
" M
IN
" M
IN
. (G) LATCH APPROACH, PUSH SIDE
(E) HINGE APPROACH, PUSH SIDE (F) LATCH APPROACH, PULL SIDE
(D) HINGE APPROACH, PULL SIDE(C) HINGE APPROACH, PULL SIDE
(A) FRONT APPROACH, PULL SIDE (B) FRONT APPROACH, PUSH
SIDE
24" MIN.
" M
IN
22" MIN.42
" M
IN
22" MIN.
" M
IN
42" MIN.
" M
IN
36" MIN.
" M
IN
18" MIN.
" M
IN
12" MIN.*
" M
IN
32" MIN.
90.
00°
(A) HINGED DOOR (B) SLIDING DOOR
(C) FOLDING DOOR
32" MIN.
32" MIN.
SCALE:
CHAPTER 3 - FLOOR SURFACES01
A-001 N.T.S
SCALE:
CHAPTER 3 - CHANGES IN LEVEL02
A-001 N.T.S
SCALE:
CHAPTER 3 - WHEELCHAIR TURNING SPACE03
A-001 N.T.S
SCALE:
CHAPTER 3 - CLEAR GROUND SPACE04
A-001 N.T.S
SCALE:
CHAPTER 3 - REACH RANGES05
A-001 N.T.S
SCALE:
CHAPTER 4 - ACCESSIBLE ROUTE06
A-001 N.T.S
SCALE:
CHAPTER 4 - DOORS AND DOORWAYS07
A-001 N.T.SSCALE:
CHAPTER 5 - STAIRWAYS08
A-001 N.T.S
SCALE:
CHAPTER 5 - HANDRAILS09
A-001 N.T.S
CO
NT
AC
T
IN
FO
RM
AT
IO
N:
DE
SI
GN
MU
LA
G
RO
UP
5 C
OT
TA
GE
H
ILL
R
OA
D
YO
RK
P
A
7.8
.01
H
AN
OV
ER
R
OA
D
YO
RK
, P
A, LI
TT
LE
C
RE
EK
P
AR
K
MA
IN
TE
NA
NC
E
BU
IL
DI
NG
AN
SI
A
7.1
(2
9)
AC
CE
SS
IB
IL
IT
Y
DE
TA
IL
S
A-001
NE
W
C
ON
ST
RU
CT
IO
N
FO
R:
BL
AI
R
LE
HM
AN
BL
EH
MA
N@
TH
EM
UL
AG
RO
UP
.C
OM
-1
M
UL
A
GR
OU
P
RE
CO
RD
O
F
IS
SU
E
DA
TE
IS
SU
E
RE
V
.12 .17
IS
SU
ED
F
OR
P
ER
MI
T
.01
.19
IS
SU
ED
F
OR
B
ID
FIGURE 306.3
KNEE CLEARANCE
306.1 GENERAL. WHERE SPACE BENEATH AN ELEMENT IS INCLUDED AS PART OF CLEAR FLOOR OR GROUND SPACE AT AN ELEMENT, CLEARANCE AT AN ELEMENT, OR A WHEELCHAIR TURNING SPACE, THE SPACE SHALL COMPLY WITH SECTION 306. ADDITIONAL SPACE BEYOND KNEE AND TOE CLEARANCE SHALL BE PERMITTED BENEATH ELEMENTS.
306.2 TOE CLEARANCE.
306.2.1 GENERAL. SPACE UNDER AN ELEMENT BETWEEN THE FLOOR OR GROUND AND 9 INCHES (230 MM) ABOVE THE FLOOR OR GROUND SHALL BE TOE CLEARANCE AND SHALL COMPLY WITH SECTION 306.2.
306.2.2 MAXIMUM DEPTH. TOE CLEARANCE SHALL BE PERMITTED TO EXTEND 25 INCHES (635 MM)
MAXIMUM UNDER AN ELEMENT.
306.2.3 MINIMUM DEPTH. WHERE TOE CLEARANCE IS REQUIRED AT AN ELEMENT AS PART OF A CLEAR
FLOOR OR GROUND SPACE, THE TOE CLEARANCE SHALL EXTEND 17 INCHES (430 MM) MINIMUM
BENEATH THE ELEMENT.
306.2.4 ADDITIONAL CLEARANCE. SPACE EXTENDING GREATER THAN 6 INCHES (150 MM) BEYOND THE AVAILABLE KNEE CLEARANCE AT 9 INCHES (230 MM) ABOVE THE FLOOR OR GROUND SHALL NOT BE
INCLUDED IN TOE CLEARANCE.
306.2.5 WIDTH. TOE CLEARANCE SHALL BE 30 INCHES (760 MM) WIDE MINIMUM.
306.3 KNEE CLEARANCE.
306.3.1 GENERAL. SPACE UNDER AN ELEMENT BETWEEN 9 INCHES (230 MM) AND 27 INCHES (685 MM) ABOVE
THE FLOOR OR GROUND SHALL BE KNEE CLEARANCE AND SHALL COMPLY WITH SECTION 306.3.
306.3.2 MAXIMUM DEPTH. KNEE CLEARANCE SHALL BE PERMITTED TO EXTEND 25 INCHES (635 MM)
MAXIMUM UNDER AN ELEMENT AT 9 INCHES (230 MM) ABOVE THE FLOOR OR GROUND.
306.3.3 MINIMUM DEPTH. KNEE CLEARANCE IS REQUIRED BENEATH AN ELEMENT AS PART OF A CLEAR FLOOR OR GROUND SPACE, THE KNEE CLEARANCE SHALL BE 11 INCHES (280 MM) DEEP MINIMUM AT 9 INCHES (230 MM) ABOVE THE FLOOR OR GROUND, AND 8 INCHES (205 MM) DEEP MINIMUM AT 27 INCHES
(685 MM) ABOVE THE FLOOR OR GROUND.
306.3.4 CLEARANCE REDUCTION. BETWEEN 9 INCHES (230 MM) AND 27 INCHES (685 MM) ABOVE THE FLOOR OR GROUND, THE KNEE CLEARANCE SHALL BE PERMITTED TO BE REDUCED AT A RATE OF 1 INCH (26 MM)
FOR EACH 6 INCHES (150 MM) IN HEIGHT.
306.3.5 WIDTH. KNEE CLEARANCE SHALL BE 30 INCHES (760 MM) WIDE MINIMUM.
307.1 GENERAL. PROTRUDING OBJECTS ON CIRCULATION PATHS SHALL COMPLY WITH SECTION 307.
307.2 PROTRUSION LIMITS. OBJECTS WITH LEADING EDGES MORE THAN 27 INCHES (685 MM) AND NOT MORE THAN 80 INCHES (2030 MM) ABOVE THE FLOOR SHALL PROTRUDE 4 INCHES (100 MM) MAXIMUM HORIZONTALLY INTO THE
CIRCULATION PATH.
EXCEPTION: HANDRAILS SHALL BE PERMITTED TO PROTRUDE 4-1/2 INCHES (115 MM) MAXIMUM.
307.3 POST-MOUNTED OBJECTS. OBJECTS ON POSTS OR PYLONS SHALL BE PERMITTED TO OVERHANG 4 INCHES (100 MM) MAXIMUM WHERE MORE THAN 27 INCHES (685 MM) AND NOT MORE THAN 80 INCHES (2030 MM) ABOVE THE FLOOR. OBJECTS ON MULTIPLE POSTS OR PYLONS WHERE THE CLEAR DISTANCE BETWEEN THE POSTS OR PYLONS IS GREATER THAN 12 INCHES (305 MM) SHALL HAVE THE LOWEST EDGE OF SUCH OBJECT EITHER 27
INCHES (685 MM) MAXIMUM OR 80 INCHES (2030 MM) MINIMUM ABOVE THE FLOOR.
EXCEPTION: SLOPING PORTIONS OF HANDRAILS BETWEEN THE TOP AND BOTTOM RISER OF STAIRS AND
ABOVE THE RAMP RUN SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 307.3.
307.4 VERTICAL CLEARANCE. VERTICAL CLEARANCE SHALL BE 80 INCHES (2030 MM) MINIMUM. RAILS OR OTHER BARRIERS SHALL BE PROVIDED WHERE THE VERTICAL CLEARANCE IS LESS THAN 80 INCHES (2030 MM). THE LEADING EDGE OF SUCH RAILS OR BARRIER SHALL BE LOCATED 27 INCHES (685 MM) MAXIMUM ABOVE THE FLOOR.
EXCEPTION: DOOR CLOSERS AND DOOR STOPS SHALL BE PERMITTED TO BE 78 INCHES (1980 MM)
MINIMUM ABOVE THE FLOOR.
307.5 REQUIRED CLEAR WIDTH. PROTRUDING OBJECTS SHALL NOT REDUCE THE CLEAR WIDTH REQUIRED FOR
ACCESSIBLE ROUTES.
FIGURE 307.2
LIMITS OF PROTRUDING OBJECTS
FIGURE 306.2
TOE CLEARANCE
(A)
ELEVATION
(B)
PLAN
(B)
PLAN
(A)
ELEVATION
406.1 GENERAL. CURB RAMPS ON ACCESSIBLE ROUTES SHALL COMPLY WITH SECTIONS 406, 405.2, 405.3, AND 405.10.
406.2 COUNTER SLOPE. COUNTER SLOPES OF ADJOINING GUTTERS AND ROAD SURFACES IMMEDIATELY ADJACENT TO THE CURB RAMP SHALL NOT BE STEEPER THAN 1:20. THE ADJACENT SURFACES AT TRANSITIONS AT CURB RAMPS TO WALKS, GUTTERS AND STREETS SHALL BE AT THE SAME LEVEL.
406.3 SIDES OF CURB RAMPS. WHERE PROVIDED, CURB RAMP FLARES SHALL COMPLY WITH SECTION 406.3.
406.3.1 SLOPE. FLARES SHALL NOT BE STEEPER THAN 1:10.
406.3.2 MARKING. IF CURBS ADJACENT TO THE RAMP FLARES ARE PAINTED, THE PAINTED SURFACE
SHALL EXTEND ALONG THE FLARED PORTION OF THE CURB.
406.4 WIDTH. CURB RAMPS SHALL BE 36 INCHES (915 MM) MINIMUM IN WIDTH, EXCLUSIVE OF THE FLARED
SIDES.
406.6 LOCATION. CURB RAMPS AND THE FLARED SIDES OF CURB RAMPS SHALL BE LOCATED SO THEY DO NOT PROJECT INTO VEHICULAR TRAFFIC LANES, PARKING SPACES, OR PARKING ACCESS AISLES. CURB RAMPS AT MARKED CROSSINGS SHALL BE WHOLLY CONTAINED WITHIN THE MARKINGS, EXCLUDING ANY FLARED SIDES.
406.7 LANDINGS. LANDINGS SHALL BE PROVIDED AT THE TOPS OF CURB RAMPS. THE CLEAR LENGTH OF THE LANDING SHALL BE 36 INCHES (915 MM) MINIMUM. THE CLEAR WIDTH OF THE LANDING SHALL BE AT LEAST AS
WIDE AS THE CURB RAMP, EXCLUDING FLARED SIDES, LEADING TO THE LANDING.
EXCEPTION: IN ALTERATIONS, WHERE THERE IS NO LANDING AT THE TOP OF CURB RAMPS, CURB
RAMP FLARES SHALL BE PROVIDED AND SHALL NOT BE STEEPER THAN 1:12.
FIGURE 406.2
COUNTER SLOPE OF SURFACES ADJACENT TO CURB RAMPS
FIGURE 406.7
LANDINGS
FIGURE 406.3
COUNTER SLOPE OF SURFACES ADJACENT TO CURB RAMPS
501 GENERAL
501.1 SCOPE. GENERAL SITE AND BUILDING ELEMENTS REQUIRED TO BE ACCESSIBLE BY THE SCOPING PROVISIONS ADOPTED BY THE ADMINISTRATIVE AUTHORITY SHALL COMPLY WITH THE APPLICABLE PROVISIONS OF CHAPTER 5.
502 PARKING SPACES
502.1 GENERAL. ACCESSIBLE CAR AND VAN PARKING SPACES SHALL COMPLY WITH SECTION 502.
502.2 VEHICLE SPACE SIZE. CAR PARKING SPACES SHALL BE 96 INCHES (2440 MM) MINIMUM IN WIDTH. VAN PARKING
SPACES SHALL BE 132 INCHES (3350 MM) MINIMUM IN WIDTH.
EXCEPTION: VAN PARKING SPACES SHALL BE PERMITTED TO BE 96 INCHES (2440 MM) MINIMUM IN WIDTH
WHERE THE ADJACENT ACCESS AISLE IS 96 INCHES (2440 MM) MINIMUM IN WIDTH.
502.3 VEHICLE SPACE MARKING. CAR AND VAN PARKING SPACES SHALL BE MARKED TO DEFINE THE WIDTH. WHERE PARKING SPACES ARE MARKED WITH LINES, THE WIDTH MEASUREMENTS OF PARKING SPACES AND ADJACENT
ACCESS AISLES SHALL BE MADE FROM THE CENTERLINE OF THE MARKINGS.
EXCEPTION: WHERE PARKING SPACES OR ACCESS AISLES ARE NOT ADJACENT TO ANOTHER PARKING SPACE OR ACCESS AISLE, MEASUREMENTS SHALL BE PERMITTED TO INCLUDE THE FULL WIDTH OF THE LINE
DEFINING THE PARKING SPACE OR ACCESS AISLE.
502.4 ACCESS AISLE. CAR AND VAN PARKING SPACES SHALL HAVE AN ADJACENT ACCESS AISLE COMPLYING WITH
SECTION 502.4.
502.4.1 LOCATION. ACCESS AISLES SHALL ADJOIN AN ACCESSIBLE ROUTE. TWO PARKING SPACES SHALL BE PERMITTED TO SHARE A COMMON ACCESS AISLE. ACCESS AISLES SHALL NOT OVERLAP WITH THE VEHICULAR WAY. PARKING SPACES SHALL BE PERMITTED TO HAVE ACCESS AISLES PLACED ON EITHER SIDE OF THE CAR OR VAN PARKING SPACE. VAN PARKING SPACES THAT ARE ANGLED SHALL HAVE
ACCESS AISLES LOCATED ON THE PASSENGER SIDE OF THE PARKING SPACE.
502.4.2 WIDTH. ACCESS AISLES SERVING CAR AND VAN PARKING SPACES SHALL BE 60 INCHES (1525 MM)
MINIMUM IN WIDTH.
502.4.3 LENGTH. ACCESS AISLES SHALL EXTEND THE FULL LENGTH OF THE PARKING SPACES THEY SERVE.
502.4.4 MARKING. ACCESS AISLES SHALL BE MARKED SO AS TO DISCOURAGE PARKING IN THEM. WHERE
ACCESS AISLES ARE MARKED WITH LINES, THE WIDTH MEASUREMENTS OF ACCESS AISLES AND
ADJACENT PARKING SPACES SHALL BE MADE FROM THE CENTERLINE OF THE MARKINGS.
EXCEPTION: WHERE ACCESS AISLES OR PARKING SPACES ARE NOT ADJACENT TO ANOTHER
ACCESS AISLE OR PARKING SPACE, MEASUREMENTS SHALL BE PERMITTED TO INCLUDE THE
FULL WIDTH OF THE LINE DEFINING THE ACCESS AISLE OR PARKING SPACE.
FIGURE 505.2
VEHICLE PARKING SPACE SIZE
FIGURE 505.4
PARKING SPACE ACCESS AISLE
602.1 GENERAL. ACCESSIBLE DRINKING FOUNTAINS SHALL COMPLY WITH SECTIONS 602 AND 307.
602.2 CLEAR FLOOR SPACE. A FLOOR SPACE COMPLYING WITH SECTION 305, POSITIONED FOR A FORWARD APPROACH TO THE DRINKING FOUNTAIN, SHALL BE PROVIDED. KNEE AND TOE SPACE COMPLYING WITH SECTION 306 SHALL BE PROVIDED. THE CLEAR FLOOR SPACE SHALL BE CENTERED ON THE DRINKING FOUNTAIN.
EXCEPTIONS:
1. DRINKING FOUNTAINS FOR STANDING PERSONS.
2. DRINKING FOUNTAINS PRIMARILY FOR CHILDREN'S USE SHALL BE PERMITTED WHERE THE SPOUT OUTLET IS 30 INCHES (760 MM) MAXIMUM ABOVE THE FLOOR, A PARALLEL APPROACH COMPLYING WITH SECTION 305 IS PROVIDED AND THE CLEAR FLOOR SPACE IS CENTERED ON THE DRINKING FOUNTAIN.
602.4 SPOUT OUTLET HEIGHT. SPOUT OUTLETS OF WHEELCHAIR ACCESSIBLE DRINKING FOUNTAINS SHALL BE 36 INCHES (915 MM) MAXIMUM ABOVE THE FLOOR. SPOUT OUTLETS OF DRINKING FOUNTAINS FOR STANDING PERSONS SHALL BE 38 INCHES (965 MM) MINIMUM AND 43 INCHES (1090 MM) MAXIMUM ABOVE THE FLOOR.
602.5 SPOUT LOCATION. THE SPOUT SHALL BE LOCATED 15 INCHES (380 MM) MINIMUM FROM THE VERTICAL SUPPORT AND 5 INCHES (125 MM) MAXIMUM FROM THE FRONT EDGE OF THE DRINKING FOUNTAIN, INCLUDING BUMPERS. WHERE ONLY A PARALLEL APPROACH IS PROVIDED, THE SPOUT SHALL BE LOCATED 3-1/2 INCHES (90
MM) MAXIMUM FROM THE FRONT EDGE OF THE DRINKING FOUNTAIN, INCLUDING BUMPERS.
FIGURE 602.2
PARALLEL APPROACH AT DRINKING FOUNTAINS
PRIMARILY FOR CHILDREN'S USE
FIGURE 602.5
DRINKING FOUNTAIN SPOUT LOCATION
(B)
ELEVATION
603.1 GENERAL. ACCESSIBLE TOILET AND BATHING ROOMS SHALL COMPLY WITH SECTION 603.
603.2 CLEARANCES.
603.2.1 TURNING SPACE. A TURNING SPACE COMPLYING WITH SECTION 304 SHALL BE PROVIDED WITHIN THE ROOM. THE REQUIRED TURNING SPACE SHALL NOT BE PROVIDED WITHIN A TOILET COMPARTMENT.
603.2.2 DOOR SWING. DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE FOR
ANY FIXTURE.
EXCEPTIONS:
1. DOORS TO A TOILET OR BATHING ROOM FOR A SINGLE OCCUPANT, ACCESSED ONLY
THROUGH A PRIVATE OFFICE AND NOT FOR COMMON USE OR PUBLIC USE SHALL BE PERMITTED
TO SWING INTO THE CLEAR FLOOR SPACE, PROVIDED THE SWING OF THE DOOR CAN BE
REVERSED TO COMPLY WITH SECTION 603.2.2.
2. WHERE THE ROOM IS FOR INDIVIDUAL USE AND A CLEAR FLOOR SPACE COMPLYING WITH
SECTION 305.3 IS PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE DOOR SWING, THE
DOOR SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 603.2.2.
603.3 MIRRORS. WHERE MIRRORS ARE LOCATED ABOVE LAVATORIES, A MIRROR SHALL BE LOCATED OVER THE ACCESSIBLE LAVATORY AND SHALL BE MOUNTED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FLOOR. WHERE MIRRORS ARE LOCATED ABOVE COUNTERS THAT DO NOT CONTAIN LAVATORIES, THE MIRROR SHALL BE MOUNTED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE 40 INCHES
(1015 MM) MAXIMUM ABOVE THE FLOOR.
EXCEPTION: OTHER THAN WITHIN ACCESSIBLE DWELLING OR SLEEPING UNITS, MIRRORS ARE NOT REQUIRED OVER THE LAVATORIES OR COUNTERS IF A MIRROR IS LOCATED WITHIN THE SAME TOILET OR BATHING ROOM AND MOUNTED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE 35 INCHES (890
MM) MAXIMUM ABOVE THE FLOOR.
603.1 GENERAL. ACCESSIBLE URINALS SHALL COMPLY WITH SECTION 605.
605.2 HEIGHT AND DEPTH. URINALS SHALL BE OF THE STALL TYPE OR SHALL BE OF THE WALL HUNG TYPE WITH THE RIM AT 17 INCHES (430 MM) MAXIMUM ABOVE THE FLOOR. WALL HUNG URINALS SHALL BE 13-1/2 INCHES (345 MM)
MINIMUM IN DEPTH MEASURED FROM THE OUTER FACE OF THE URINAL RIM TO THE WALL.
605.3 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE COMPLYING WITH SECTION 305, POSITIONED FOR FORWARD
APPROACH, SHALL BE PROVIDED.
605.4 FLUSH CONTROLS. FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH
CONTROLS SHALL COMPLY WITH SECTION 309.
FIGURE 605.2
HEIGHT OF URINALS
(B)
STALL TYPE
604.1 GENERAL. ACCESSIBLE WATER CLOSETS AND TOILET COMPARTMENTS SHALL COMPLY WITH SECTION 604.
COMPARTMENTS CONTAINING MORE THAN ONE PLUMBING FIXTURE SHALL COMPLY WITH SECTION 603. WHEELCHAIR ACCESSIBLE COMPARTMENTS SHALL COMPLY WITH SECTION 604.9. AMBULATORY ACCESSIBLE COMPARTMENTS
SHALL COMPLY WITH SECTION 604.10.
EXCEPTION: WATER CLOSETS AND TOILET COMPARTMENTS PRIMARILY FOR CHILDREN'S USE SHALL BE
PERMITTED TO COMPLY WITH SECTION 604.11 AS APPLICABLE.
604.2 LOCATION. THE WATER CLOSET SHALL BE LOCATED WITH A WALL OR PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE OF THE WATER CLOSET SHALL BE 16 INCHES (405 MM) MINIMUM AND 18 INCHES (455 MM) MAXIMUM FROM THE SIDE WALL OR PARTITION. WATER CLOSETS LOCATED IN AMBULATORY ACCESSIBLE COMPARTMENTS SPECIFIED IN SECTION 604.10 SHALL HAVE THE CENTERLINE OF THE WATER CLOSET 17 INCHES (430
MM) MINIMUM AND 19 INCHES (485 MM) MAXIMUM FROM THE SIDE WALL OR PARTITION.
604.3 CLEARANCE.
604.3.1 CLEARANCE WIDTH. CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES (1525 MM) MINIMUM
IN WIDTH, MEASURED PERPENDICULAR FROM THE SIDE WALL.
604.3.2 CLEARANCE DEPTH. CLEARANCE AROUND THE WATER CLOSET SHALL BE 56 INCHES (1420 MM)
MINIMUM IN DEPTH, MEASURED PERPENDICULAR FROM THE REAR WALL.
604.3.3 CLEARANCE OVERLAP. THE REQUIRED CLEARANCE AROUND THE WATER CLOSET SHALL BE PERMITTED TO OVERLAP THE WATER CLOSET, ASSOCIATED GRAB BARS, PAPER DISPENSERS, SANITARY NAPKIN RECEPTACLES, COAT HOOKS, SHELVES, ACCESSIBLE ROUTES, CLEAR FLOOR SPACE AT OTHER FIXTURES, AND THE TURNING SPACE. NO OTHER FIXTURES OR OBSTRUCTIONS SHALL BE WITHIN THE
REQUIRED WATER CLOSET CLEARANCE.
604.4 HEIGHT. THE HEIGHT OF WATER CLOSET SEATS SHALL BE 17 INCHES (430 MM) MINIMUM AND 19 INCHES (485 MM) MAXIMUM ABOVE THE FLOOR, MEASURED TO THE TOP OF THE SEATS. SEATS SHALL NOT BE SPRUNG TO RETURN TO
A LIFTED POSITION.
EXCEPTION: A WATER CLOSET IN A TOILET ROOM FOR A SINGLE OCCUPANT, ACCESSED ONLY THROUGH A PRIVATE OFFICE AND NOT FOR COMMON USE OR PUBLIC USE, SHALL NOT BE REQUIRED TO COMPLY WITH
SECTION 604.4.
604.5 GRAB BARS. GRAB BARS FOR WATER CLOSETS SHALL COMPLY WITH SECTION 609 AND SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS 604.5.1 AND 604.5.2. GRAB BARS SHALL BE PROVIDED ON THE REAR WALL AND ON THE
SIDE WALL CLOSEST TO THE WATER CLOSET.
EXCEPTIONS:
1. GRAB BARS ARE NOT REQUIRED TO BE INSTALLED IN A TOILET ROOM FOR A SINGLE OCCUPANT, ACCESSED ONLY THROUGH A PRIVATE OFFICE AND NOT FOR COMMON USE OR PUBLIC USE, PROVIDED REINFORCEMENT HAS BEEN INSTALLED IN WALLS AND LOCATED SO AS TO PERMIT THE INSTALLATION OF
GRAB BARS COMPLYING WITH SECTION 604.5.
2. IN DETENTION OR CORRECTION FACILITIES, GRAB BARS ARE NOT REQUIRED TO BE INSTALLED IN HOUSING OR HOLDING CELLS OR ROOMS THAT ARE SPECIALLY DESIGNED WITHOUT PROTRUSIONS FOR PURPOSES OF
SUICIDE PREVENTION.
604.5.1 FIXED SIDE WALL GRAB BARS. FIXED SIDE-WALL GRAB BARS SHALL BE 42 INCHES (1065 MM) MINIMUM IN LENGTH, LOCATED 12 INCHES (305 MM) MAXIMUM FROM THE REAR WALL AND EXTENDING 54 INCHES (1370 MM) MINIMUM FROM THE REAR WALL. IN ADDITION, A VERTICAL GRAB BAR 18 INCHES (455 MM) MINIMUM IN LENGTH SHALL BE MOUNTED WITH THE BOTTOM OF THE BAR LOCATED 39 INCHES (990 MM) MINIMUM AND 41 INCHES (1040 MM) MAXIMUM ABOVE THE FLOOR, AND WITH THE CENTERLINE OF THE BAR LOCATED 39 INCHES (990 MM) MINIMUM AND 41
INCHES (1040 MM) MAXIMUM FROM THE REAR WALL.
EXCEPTION: THE VERTICAL GRAB BAR AT WATER CLOSETS PRIMARILY FOR CHILDREN'S USE SHALL COMPLY
WITH SECTION 609.4.2.
604.5.2 REAR WALL GRAB BARS. THE REAR WALL GRAB BARS SHALL BE 36 INCHES (915 MM) MINIMUM IN LENGTH, AND EXTEND FROM THE CENTERLINE OF THE WATER CLOSET 12 INCHES (305 MM) MINIMUM ON THE SIDE CLOSEST TO THE
WALL, AND 24 INCHES (610 MM) MINIMUM ON THE TRANSFER SIDE.
EXCEPTIONS:
1. THE REAR GRAB BAR SHALL BE PERMITTED TO BE 24 INCHES (610 MM) MINIMUM IN LENGTH, CENTERED ON THE WATER CLOSET, WHERE WALL SPACE DOES NOT PERMIT A GRAB BAR 36 INCHES (915 MM) MINIMUM IN
LENGTH DUE TO THE LOCATION OF A RECESSED FIXTURE ADJACENT TO THE WATER CLOSET.
2. WHERE AN ADMINISTRATIVE AUTHORITY REQUIRES FLUSH CONTROLS FOR FLUSH VALVES TO BE LOCATED IN A POSITION THAT CONFLICTS WITH THE LOCATION OF THE REAR GRAB BAR, THAT GRAB BAR SHALL BE
PERMITTED TO BE SPLIT OR SHIFTED TO THE OPEN SIDE OF THE TOILET AREA.
604.9 WHEELCHAIR ACCESSIBLE COMPARTMENTS.
604.9.1 GENERAL. WHEELCHAIR ACCESSIBLE COMPARTMENTS SHALL COMPLY WITH SECTION 604.9.
604.9.2 SIZE. TOILET COMPARTMENTS SHALL COMPLY WITH SECTION 604.9.2.1 OR 604.9.2.2 AS APPLICABLE.
604.9.2.1 MINIMUM AREA. THE MINIMUM AREA OF A WHEELCHAIR ACCESSIBLE COMPARTMENT SHALL BE 60 INCHES (1525 MM) MINIMUM IN WIDTH MEASURE PERPENDICULAR TO THE SIDE WALL, AND 56 ICHES (1420 MM) MINIMUM IN DEPTH FOR WALL HUNG WATER CLOSETS, AND 59 INCHES (1500 MM) MINIMUM IN DEPTH FOR
FLOOR MOUNTED WATER CLOSETS MEASURED PERPENDICULAR TO THE REAR WALL.
604.9.3 DOORS. TOILET COMPARTMENT DOORS, INCLUDING DOOR HARDWARE, SHALL COMPLY WITH SECTION 404, EXCEPT IF THE APPROACH IS TO THE LATCH SIDE OF THE COMPARTMENT DOOR CLEARANCE BETWEEN THE DOOR SIDE OF THE STALL AND ANY OBSTRUCTION SHALL BE 42 INCHES (1065 MM) MINIMUM. THE DOOR SHALL BE SELF- CLOSING. A DOOR PULL COMPLYING WITH SECTION 404.2.6 SHALL BE PLACED ON BOTH SIDES OF THE DOOR NEAR THE LATCH. TOILET COMPARTMENT DOORS SHALL NOT SWING INTO THE REQUIRED MINIMUM AREA OF THE
COMPARTMENT.
604.9.3.1 DOOR OPENING LOCATION. THE FARTHEST LEDGE OF TOILET COMPARTMENT DOOR OPENING SHALL BE LOCATED IN THE FRONT WALL OR PARTITION OR IN THE SIDE WALL OR PARTITION AS REQUIRED
BY TABLE 604.9.3.1.
604.9.6 GRAB BARS. GRAB BARS SHALL COMPLY WITH SECTION 609. SIDE WALL GRAB BARS COMPLYING WITH SECTION 604.5.1 LOCATED ON THE WALL CLOSEST TO THE WATER CLOSET, AND A REAR WALL GRAB BAR COMPLYING
WITH SECTION 604.5.2, SHALL BE PROVIDED.
FIGURE 604.2
WATER CLOSET LOCATIONS
FIGURE 604.3
SIZE OF CLEARANCE FOR WATER CLOSET
(A)
WHEELCHAIR ACCESSIBLE
WATER CLOSETS
(B)
AMBULATORY ACCESSIBLE
WATER CLOSETS
FIGURE 604.9.2
WHEELCHAIR ACCESSIBLE TOILET COMPARTMENTS
FIGURE 604.10
AMBULATORY ACCESSIBLE TOILET COMPARTMENTS
(A)
ADULT WALL HUNG
WATER CLOSET
(B)
ADULT FLOOR MOUNTED WATER CLOSET
AND CHILDRENS WATER CLOSET
606.1 GENERAL. ACCESSIBLE LAVATORIES AND SINKS SHALL COMPLY WITH SECTION 606.
606.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE COMPLYING WITH SECTION 305.3, POSITIONED FOR FORWARD APPROACH, SHALL BE PROVIDED. KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 306 SHALL BE PROVIDED.
THE DIP OF THE OVERFLOW SHALL NOT BE CONSIDERED IN DETERMINING KNEE AND TOE CLEARANCES.
EXCEPTIONS:
1. A PARALLEL APPROACH COMPLYING WITH SECTION 305 AND CENTERED ON THE SINK, SHALL BE
PERMITTED TO A KITCHEN SINK IN A SPACE WHERE A COOK TOP OR CONVENTIONAL RANGE IS NOT PROVIDED.
2. THE REQUIREMENT FOR KNEE AND TOE CLEARANCE SHALL NOT APPLY TO A LAVATORY IN A TOILET OR
BATHING FACILITY FOR A SINGLE OCCUPANT, ACCESSED ONLY THROUGH A PRIVATE OFFICE AND NOT FOR
COMMON USE OR PUBLIC USE.
3. KNEE CLEARANCE OF 24 INCHES (610 MM) MINIMUM ABOVE THE FLOOR SHALL BE PERMITTED AT LAVATORIES AND SINKS USED PRIMARILY BY CHILDREN AGES 6 THROUGH 12 WHERE THE RIM OR COUNTER
SURFACE IS 31 INCHES (785 MM) MAXIMUM ABOVE THE FLOOR.
4. A PARALLEL APPROACH COMPLYING WITH SECTION 305 AND CENTERED ON THE SINK, SHALL BE
PERMITTED AT LAVATORIES AND SINKS USED PRIMARILY BY CHILDREN AGES 5 AND YOUNGER.
5. THE REQUIREMENT FOR KNEE AND TOE CLEARANCE SHALL NOT APPLY TO MORE THAN ONE BOWL OF A
MULTIBOWL SINK.
6. A PARALLEL APPROACH COMPLYING WITH SECTION 305 AND CENTERED ON THE SINK, SHALL BE
PERMITTED AT WET BARS.
606.3 HEIGHT. THE FRONT OF LAVATORIES AND SINKS SHALL BE 34 INCHES (865 MM) MAXIMUM ABOVE THE FLOOR, MEASURED TO THE HIGHER OF THE RIM OR COUNTER SURFACE.
EXCEPTION: A LAVATORY IN A TOILET OR BATHING FACILITY FOR A SINGLE OCCUPANT, ACCESSED ONLY THROUGH A PRIVATE OFFICE AND NOT FOR COMMON USE OR PUBLIC USE SHALL NOT BE REQUIRED TO COMPLY
WITH SECTION 606.3.
606.4 FAUCETS. FAUCETS SHALL COMPLY WITH SECTION 309. HAND OPERATED METERING FAUCETS SHALL REMAIN
OPEN FOR 10 SECONDS MINIMUM.
606.5 LAVATORIES WITH ENHANCED REACH RANGE. WHERE ENHANCED REACH RANGE IS REQUIRED AT LAVATORIES, FAUCETS AND SOAP DISPENSER CONTROLS SHALL HAVE A REACH DEPTH OF 11 INCHES (280 MM) MAXIMUM OR, IF AUTOMATIC, SHALL BE ACTIVATED WITHIN A REACH DEPTH OF 11 INCHES (280 MM) MAXIMUM.
606.6 EXPOSED PIPES AND SURFACES. WATER SUPPLY AND DRAINPIPES UNDER LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR
ABRASIVE SURFACES UNDER LAVATORIES AND SINKS.
609.1 GENERAL. GRAB BARS IN ACCESSIBLE TOILET OR BATHING FACILITIES SHALL COMPLY WITH SECTION 609.
609.2 CROSS SECTION. GRAB BARS SHALL HAVE A CROSS SECTION COMPLYING WITH SECTION 609.2.1 OR 609.2.2.
609.2.1 CIRCULAR CROSS SECTION. GRAB BARS WITH A CIRCULAR CROSS SECTION SHALL HAVE AN
OUTSIDE DIAMETER OF 1-1/4 INCH (32 MM) MINIMUM AND 2 INCHES (51 MM) MAXIMUM.
609.2.2 NONCIRCULAR CROSS SECTION. GRAB BARS WITH A NONCIRCULAR CROSS SECTION SHALL HAVE A CROSS SECTION DIMENSION OF 2 INCHES (51 MM) MAXIMUM, AND A PERIMETER DIMENSION OF 4 INCHES (100 MM)
MINIMUM AND 4.8 INCHES (120 MM) MAXIMUM.
609.3 SPACING. THE SPACE BETWEEN THE WALL AND THE GRAB BAR SHALL BE 1-1/2 INCHES (38 MM). THE SPACE BETWEEN THE GRAB BAR AND PROJECTING OBJECTS BELOW AND AT THE ENDS OF THE GRAB BAR SHALL BE 1-1/2 INCHES (38 MM) MINIMUM. THE SPACE BETWEEN THE GRAB BAR AND PROJECTING OBJECTS ABOVE THE GRAB BAR
SHALL BE 12 INCHES (305 MM) MINIMUM.
EXCEPTIONS:
1. THE SPACE BETWEEN THE GRAB BARS AND SHOWER CONTROLS, SHOWER FITTINGS, AND OTHER GRAB
BARS ABOVE THE GRAB BAR SHALL BE PERMITTED TO BE 1-1/2 INCHES (38 MM) MINIMUM.
2. RECESSED DISPENSERS PROJECTING FROM THE WALL 1/4 INCHES (6.4 MM) MAXIMUM MEASURED FROM
THE FACE OF THE DISPENSER AND COMPLYING WITH SECTION 604.7 SHALL BE PERMITTED WITHIN THE 12-INCH (305 MM) SPACE ABOVE AND THE 1-1/2 INCH (38 MM) SPACES BELOW AND THE ENDS OF THE GRAB BAR.
609.4 POSITION OF GRAB BARS.
609.4.1 GENERAL. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM) MAXIMUM ABOVE THE FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE OR SHALL BE
INSTALLED AS REQUIRED BY ITEMS 1 THROUGH 3.
1. THE LOWER GRAB BAR ON THE BACK WALL OF A BATHTUB SHALL COMPLY WITH SECTION 607.4.1.1 OR 607.4.2.1.
2. VERTICAL GRAB BARS SHALL COMPLY WITH SECTIONS 604.5.1, 607.4.1.2.2, 607.4.2.2, AND 608.3.1.2.
3. GRAB BARS AT WATER CLOSETS PRIMARILY FOR CHILDREN'S USE SHALL COMPLY WITH SECTION 609.4.2.
609.4.2 POSITION OF CHILDREN'S GRAB BARS. AT WATER CLOSETS PRIMARILY FOR CHILDREN'S USE COMPLYING WITH SECTION 604.11, GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION 18 INCHES (455 MM) MINIMUM AND 27 INCHES (685 MM) MAXIMUM ABOVE THE FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE. A VERTICAL GRAB BAR SHALL BE MOUNTED WITH THE BOTTOM OF THE BAR LOCATED BETWEEN 21 INCHES (535 MM) MINIMUM AND 30 INCHES (760 MM) MAXIMUM ABOVE THE FLOOR AND WITH THE CENTERLINE OF THE BAR LOCATED BETWEEN 34 INCHES (865 MM) MINIMUM AND 36 INCHES (915 MM) MAXIMUM FROM THE REAR WALL.
609.5 SURFACE HAZARDS. GRAB BARS, AND ANY WALL OR OTHER SURFACES ADJACENT TO GRAB BARS, SHALL BE
FREE OF SHARP OR ABRASIVE ELEMENTS. EDGES SHALL BE ROUNDED.
609.7 INSTALLATION AND CONFIGURATION. GRAB BARS SHALL BE INSTALLED IN ANY MANNER THAT PROVIDES A GRIPPING SURFACE AT THE LOCATIONS SPECIFIED IN THIS STANDARD AND DOES NOT OBSTRUCT THE CLEAR FLOOR SPACE. HORIZONTAL AND VERTICAL GRAB BARS SHALL BE PERMITTED TO BE SEPARATE BARS, A SINGLE
PIECE BAR, OR A COMBINATION THEREOF.
609.8 STRUCTURAL STRENGTH. ALLOWABLE STRESSES SHALL NOT BE EXCEEDED FOR MATERIALS USED WHERE A VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS (1112 N) IS APPLIED AT ANY POINT ON THE GRAB BAR, FASTENER
MOUNTING DEVICE, OR SUPPORTING STRUCTURE.
FIGURE 609.2
SIZE OF GRAB BARS
(A)
CIRCULAR
(B)
RECTANGULAR
(C)
ELLIPTICAL
FIGURE 609.3
SPACING OF GRAB BARS
(A)
PROJECTING OBJECTS
(B)
RECESSED OBJECTS
4" MAX
X
X
" M
AX
X
FIGURE 307.4
REDUCED VERTICAL CLEARANCE
11" MIN.
9"
" M
IN
8" MIN.
25" MAX.
" M
IN
6" MAX
9"
�17" - 25"
" M
IN
SLOPESLOPE
FLARED SIDES 1:10
MAX SLOPE
ADJOINING SURFACE
MAXIMUM SLOPE
CURB RAMP SLOPE
" M
IN
AT LEAST AS WIDE AS
CURB RAMP
(A)
CARS
(B)
VANS
FU
LL
LE
NG
TH
O
F
PA
RK
IN
G
SP
AC
E
60" MIN. AREA TO BE
MARKED
96" MIN. 132" MIN.
(A)
PLAN
5" MAX 15" MIN.
" M
AX
W
HE
EL
CH
AI
R
AC
CE
SS
IB
LE
" S
TA
ND
IN
G
PE
RS
ON
3 1/2" MAX PER 602.5
5" MAX. 15" MIN.
(A)
WALL HUNG TYPE
13 1/2" MIN.
" M
AX
13 1/2" MIN.
16" - 18" 17" - 19" 56 " M
IN
60" MIN.
" M
IN
.35" - 37"
" M
IN
60" MIN.60" MIN.
" M
IN
" M
IN
1 1/4" - 2"
1"
4 TO 4.8 PERIMETER
2" MAX.
" M
IN
1 1 /2"
M
IN
SURFACE MOUNTED
SOAP DISPENSER
SURFACE MOUNTED
PAPER TOWEL DISPENSER
WALL HUNG LAVATORY
& SURFACE MOUNTED
MIRROR
INSULATE ALL EXPOSED
PIPES
WALL HUNG LAVATORY &
SURFACE MOUNTED
MIRROR
20" - 25"
11" MIN.
6"
MIN.
" M
IN
9" MI
N.
" M
AX
" M
AX
TO
R
EF
LE
CT
VE
S
UR
FA
CE
" M
IN
. 33
3'
-4
" M
IN
�3'-6"
�3'-4"
12" MAX.
60" MIN.
SE
AT
H T.
H.C WATER CLOSET
AND S.S. GRAB BARS
SURFACE MOUNTED TOILET
PAPER HOLDER
H.C. WATER CLOSET
AND S.S. GRAB BARS
�1'-6"
" M
IN
3'
-4
" M
IN
SE
AT
H T. 33
1'-0" MIN. 2'-0" MIN.
60" MIN.
PROVIDE ADEQUATE WOOD
BLOCKING IN WALL FOR
GRAB BAR (TYP.)
3'-0" MIN.
2'-0" MIN.
3'-6" MAX
SURFACE MOUNTED
TOILET PAPER HOLDER
2'-
" M
AX
" M
AX
" M
AX
SCALE:
CHAPTER 3 - KNEE & TOE CLEARANCE01
A-002 N.T.S
SCALE:
CHAPTER 3 - PROTRUDING OBJECTS02
A-002 N.T.S
SCALE:
CHAPTER 4 - CURB RAMPS03
A-002 N.T.S
SCALE:
CHAPTER 5 - GENERAL SITE AND BUILDING ELEMENTS04
A-002 N.T.S
SCALE:
CHAPTER 6 - TYPICAL ADA RESTROOM CLEARANCES05
A-002 N.T.S
SCALE:
CHAPTER 6 - DRINKING FOUNTAINS06
A-002 N.T.S
SCALE:
CHAPTER 6 - TOILET AND BATHING ROOMS07
A-002 N.T.S
SCALE:
CHAPTER 6 - URINALS08
A-002 N.T.S
SCALE:
CHAPTER 6 - TOILET AND BATHING ROOMS09
A-002 N.T.SSCALE:
CHAPTER 6 - LAVATORIES AND SINKS10
A-002 N.T.S
SCALE:
CHAPTER 6 - GRAB BARS11
A-002 N.T.S
CO
NT
AC
T
IN
FO
RM
AT
IO
N:
DE
SI
GN
MU
LA
G
RO
UP
5 C
OT
TA
GE
H
ILL
R
OA
D
YO
RK
P
A
7.8
.01
H
AN
OV
ER
R
OA
D
YO
RK
, P
A, LI
TT
LE
C
RE
EK
P
AR
K
MA
IN
TE
NA
NC
E
BU
IL
DI
NG
AN
SI
A
7.1
(2
9)
AC
CE
SS
IB
IL
IT
Y
DE
TA
IL
S
A-002
NE
W
C
ON
ST
RU
CT
IO
N
FO
R:
BL
AI
R
LE
HM
AN
BL
EH
MA
N@
TH
EM
UL
AG
RO
UP
.C
OM
-1
M
UL
A
GR
OU
P
RE
CO
RD
O
F
IS
SU
E
DA
TE
IS
SU
E
RE
V
.12 .17
IS
SU
ED
F
OR
P
ER
MI
T
.01
.19
IS
SU
ED
F
OR
B
ID
LIBRARY
MEN
702.1 GENERAL. ACCESSIBLE FIRE ALARM SYSTEMS SHALL HAVE AUDIBLE ALARMS COMPLYING WITH SECTION
702.2, AND VISUAL ALARMS COMPLYING WITH SECTION 702.3.
EXCEPTION: FIRE ALARM SYSTEMS IN MEDICAL CARE FACILITIES SHALL BE PERMITTED TO BE MODIFIED
TO SUIT STANDARD HEALTH CARE ALARM PRACTICE.
702.2 AUDIBLE ALARMS. AUDIBLE ALARMS SHALL PRODUCE A SOUND THAT EXCEEDS THE AVERAGE AMBIENT SOUND LEVEL IN THE ROOM OR SPACE BY AT LEAST 15 DBA OR EXCEEDS ANY MAXIMUM SOUND LEVEL WITH A DURATION OF 60 SECONDS BY 5 DBA, WHICHEVER IS LOUDER. THE SIGNAL SHALL CONSIST OF A "THREE PULSE" TEMPORAL PATTERN COMPLYING WITH ANSI 53.41, WHERE EVACUATION OF THE BUILDING IS REQUIRED. SOUND
LEVELS FOR ALARM SIGNALS SHALL NOT EXCEED 120 DBA.
702.3 VISUAL ALARMS. VISUAL ALARMS SHALL COMPLY WITH SECTIONS 702.3.1 THROUGH 702.3.6.
702.3.1 LIGHT PULSE CHARACTERISTICS.
702.3.1.1 TYPE. THE LAMP SHALL BE XENON STROBE TYPE OR EQUIVALENT.
702.3.1.2 COLOR. THE COLOR SHALL BE CLEAR OR NOMINAL WHITE.
702.3.1.3 FLASH RATE. THE FLASH RATE FOR AN INDIVIDUAL APPLIANCE SHALL BE 1 HZ
MINIMUM AND 2 HZ MAXIMUM OVER ITS RATED VOLTAGE RANGE.
702.3.1.4 PULSE DURATION. THE MAXIMUM PULSE DURATION SHALL BE TWO-TENTHS OF ONE
SECOND WITH A MAXIMUM DUTY CYCLE OF 40 PERCENT. THE PULSE DURATION IS DEFINED AS
THE TIME INTERVAL BETWEEN INITIAL AND FINAL POINTS OF 10 PERCENT OF MAXIMUM
SIGNAL.
702.3.2 DISPERSION. LIGHT DISPERSION OF WALL-MOUNTED APPLIANCES SHALL COMPLY WITH TABLE 702.3.2(A). LIGHT DISPERSION OF CEILING-MOUNTED APPLIANCES SHALL COMPLY WITH TABLE 702.3.2(B).
702.3.3 LOCATION. APPLIANCES SHALL COMPLY WITH SECTION 702.3.3.1 OR 702.3.3.2.
EXCEPTION: APPLIANCES IN SLEEPING ROOMS SHALL COMPLY WITH SECTION 702.3.6.
702.3.3.1 WALL-MOUNTED APPLIANCES. APPLIANCES SHALL BE 80 INCHES (2030 MM) MINIMUM
AND 96 INCHES (2440 MM) MAXIMUM ABOVE THE FLOOR OR GROUND, MEASURED TO THE
BOTTOM OF THE APPLIANCE.
EXCEPTION: WALL-MOUNTED APPLIANCES WHICH ARE PART OF A SMOKE DETECTOR
SHALL BE 4 INCHES (100 MM) MINIMUM AND 12 INCHES (305 MM) MAXIMUM BELOW THE
CEILING, MEASURED TO THE TOP OF THE SMOKE DETECTOR.
702.3.4 SPACING AND INTENSITY. SPACING AND MINIMUM EFFECTIVE INTENSITY FOR APPLIANCES
SHALL COMPLY WITH SECTIONS 702.3.4.1 THROUGH 702.3.4.3.
EXCEPTIONS:
1. APPLIANCES IN CORRIDORS SHALL COMPLY WITH SECTION 702.3.5.
2. APPLIANCES IN SLEEPING ROOMS SHALL COMPLY WITH SECTION 702.3.6.
702.3.4.1 GENERAL. THE SIGNAL PROVIDED BY THE APPLIANCE OR APPLIANCES SHALL BE
VISIBLE EITHER BY DIRECT VIEW OR BY REFLECTION FROM ALL PARTS OF THE COVERED
AREA. MULTIPLE APPLIANCES WITHIN AN AREA ARE PERMITTED ONLY WHERE SIZE, SHAPE,
BUILDING CONSTRUCTION, OR FURNISHINGS PROHIBIT TOTAL COVERAGE BY A SINGLE
APPLIANCE. WHERE MULTIPLE APPLIANCES ARE PROVIDED IN A SINGLE AREA TO PROVIDE
TOTAL COVERAGE, THE APPLIANCES SHALL COMPLY WITH ONE OF THE FOLLOWING:
(1) A MAXIMUM OF 2 APPLIANCES ON OPPOSITE WALLS
(2) THE APPLIANCES SHALL HAVE SYNCHRONIZED FLASHES
(3) IN ROOMS 80 FEET BY 80 FEET (24 M BY 24 M) OR GREATER IN SIZE, MORE THAN
TWO APPLIANCES SUCH THAT ALL APPLIANCES IN ANY 135-DEGREE FIELD OF VIEW
ARE SPACED A MINIMUM OF 55 FEET (17 M) FROM EACH OTHER.
702.3.4.2 WALL-MOUNTED APPLIANCES. SPACING AND MINIMUM EFFECTIVE INTENSITY FOR
WALL-MOUNTED APPLIANCES SHALL COMPLY WITH TABLE 702.4.2, PROVIDED THE APPLIANCE
IS AT THE MIDPOINT OF THE LONGEST SIDE OF THE AREA SERVED. WHERE THE APPLIANCE IS
NOT AT THE MIDPOINT, THE MINIMUM EFFECTIVE INTENSITY SHALL BE BASED ON A MAXIMUM
AREA OF COVERAGE EQUAL TO THE DISTANCE TO THE OPPOSITE SIDE OF THE AREA SERVED,
OR DOUBLE THE DISTANCE TO THE FARTHEST ADJACENT SIDE OF THE AREA SERVED,
WHICHEVER IS GREATER
702.3.4.3 CEILING MOUNTED APPLIANCES. SPACING AND MINIMUM EFFECTIVE INTENSITY FOR
CEILING-MOUNTED APPLIANCES SHALL COMPLY WITH TABLE 702.3.4.2, PROVIDED THE
APPLIANCE IS THE CENTER POINT OF THE AREA SERVED. WHERE THE APPLIANCE IS NOT AT
THE CENTER POINT, THE MINIMUM EFFECTIVE INTENSITY SHALL BE BASED ON A MAXIMUM
AREA OF COVERAGE EQUAL TO TWO TIMES THE DISTANCE FROM THE APPLIANCE TO THE
FARTHEST SIDE OF THE AREA SERVED.
702.3.5 CORRIDORS. APPLIANCES IN CORRIDORS THAT ARE 20 FEET (6095 MM) WIDE MAXIMUM SHALL COMPLY WITH SECTION 702.3.5. APPLIANCES IN CORRIDORS EXCEEDING 20 FEET (6095 MM) IN WIDTH
SHALL COMPLY WITH SECTION 702.3.4.
702.3.5.1 APPLIANCE SPACING. APPLIANCES SHALL BE 15 FEET (4570 MM) MAXIMUM FROM
EACH END OF THE CORRIDOR, AND SHALL BE 50 FEET (15 M) MINIMUM AND 100 FEET (30 M)
MAXIMUM APART ALONG THE CORRIDOR. INTERRUPTIONS TO THE CONCENTRATED VIEWING
PATH BY DOORS, ELEVATION CHANGES, OR OTHER OBSTRUCTIONS SHALL CONSTITUTE THE
END OF THE CORRIDOR FOR THE PURPOSE OF THIS SECTION.
702.3.5.2 MINIMUM EFFECTIVE INTENSITY. APPLIANCES SHALL HAVE A MINIMUM EFFECTIVE
INTENSITY OF 15 CANDELA.
702.3.6 SLEEPING ROOMS AND SUITES. VISUAL ALARM APPLIANCES REQUIRED IN SLEEPING ROOMS
AND SUITES SHALL COMPLY WITH SECTIONS 702.3.6.1 THROUGH 702.3.6.3.
702.3.6.1 ACTIVATION. WHERE SINGLE OR MULTIPLE-STATION SMOKE DETECTORS ARE
PROVIDED IN THE SLEEPING ROOM OR SUITE, A VISUAL ALARM THAT IS ACTIVATED UPON
ACTIVATION OF THE SMOKE DETECTORS SHALL BE PROVIDED WITHIN THE ROOM OR SUITE.
WHERE A BUILDING FIRE ALARM SYSTEM IS PROVIDED, A VISUAL ALARM THAT IS ACTIVATED
UPON ACTIVATION OF THE BUILDING FIRE ALARM SYSTEM SHALL BE PROVIDED WITHIN THE
ROOM OR SUITE. THE SIGNALING LINE OR CHANNEL BETWEEN THE ACTIVATING DEVICE OF
THE APPLIANCE AND THE BUILDING FIRE ALARM SYSTEM SHALL BE MONITORED FOR
INTEGRITY BY THE BUILDING FIRE ALARM SYSTEM. WHERE THE SAME APPLIANCE IS USED FOR
VISUAL NOTIFICATION OF SMOKE DETECTOR AND FIRE ALARM SYSTEM ACTIVATION,
ACTIVATION OF THE ROOM OR SUITE SMOKE DETECTORS SHALL NOT ACTIVATE THE BUILDING
FIRE ALARM SYSTEM.
702.3.6.2 LOCATION. IN SLEEPING ROOMS OR SUITES HAVING A LINEAR DIMENSIONS
EXCEEDING 16 FEET (8475 MM), THE APPLIANCE SHALL BE 16 FEET (4875 MM) MAXIMUM FROM
THE HEAD OF THE BED LOCATION, MEASURED HORIZONTALLY. APPLIANCES SHALL BE
PERMANENTLY INSTALLED. WHERE A SUITE CONTAINS MORE THAN ONE SLEEPING ROOM, AN
APPLIANCE SHALL BE PROVIDED IN EACH SLEEPING ROOM.
702.3.6.3 MINIMUM EFFECTIVE INTENSITY AND MOUNTING HEIGHT. WALL-MOUNTED
APPLIANCES 24 INCHES (610 MM) MINIMUM BELOW THE CEILING SHALL HAVE A MINIMUM
EFFECTIVE INTENSITY OF 110 CANDELA. CEILING MOUNTED APPLIANCES AND WALL-MOUNTED
APPLIANCES LESS THAN 24 INCHES (610 MM) BELOW THE CEILING SHALL HAVE A MINIMUM
EFFECTIVE INTENSITY OF 177 CANDELA.
FIGURE 702.3.3.1
LOCATION OF WALL-MOUNTED APPLIANCES
FIGURE 702.3.3.2
LOCATION OF CEILING-MOUNTED APPLIANCES
(A) WALL ALARM (B) WALL ALARM W/
SMOKE DETECTOR
703 SIGNS
703.1 GENERAL. ACCESSIBLE SIGNS SHALL COMPLY WITH SECTION 703. TACTILE SIGNS SHALL CONTAIN BOTH RAISED CHARACTERS AND BRAILLE.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .