5400 Mill Street Suite A, Reno, NV 89502 (775) 827-2717 Fax (775) 324-5577 www.WiseCandT.com
June 16, 2021
Wise Project No. 21-142
Air National Guard Reno
1776 National Guard Way
Reno, NV 89502
Attn: Lea Laney
RE: OSHA LEAD RENOVATION SURVEY
NORTH OFFICE AREA OF BUILDING 76
1776 National Guard Way
Reno, NV 89502
Wise Consulting and Training, Inc. (WISE) was contracted to conduct an OSHA Lead
Renovation survey at the site referenced above. An environment consultant from WISE conducted the field work for the survey on June 8, 2021. The scope of work that necessitated this survey includes the intended renovation of an office area in the north portion of the building. Our lead survey work included investigating for the presence or absence of Lead-Based
Paint (LBP), Lead-Containing Paint (LCP) or Lead-Containing Materials (LCM) in areas of the renovation.
For OSHA renovation surveys we use the following surface classification system for painted, varnished, or coated surfaces. We consider any painted/coated surface that is equal to or below
0.10 milligrams per square centimeter (mg/c²) very low or no-lead for the purpose of normal renovation work. Painted/coated surfaces that are between 0.10 (mg/c²) and 1.0 (mg/c²) are considered Lead-Containing Paint (LCP) surfaces and special procedures and an OSHA Lead
Compliance Plan may be necessary depending on the condition and location of the painted/coated surfaces. Painted/coated surfaces measuring 1.0 mg/cm2 or higher are considered
Lead-Based Paint (LBP) surfaces and we recommend any disturbance of those surfaces be performed under a Lead Compliance Plan if the surfaces will be disturbed.
This survey was conducted with the use of a Niton XLp 703 AW XRF Analyzer with current calibration. If any inconclusive or atypical readings are recorded, the inspector will conduct chip sampling and laboratory analysis of the paint film to resolve the inconclusive or atypical XRF readings. No inconclusive readings were recorded at the site.
FINDINGS
The following table includes the paint description, paint combination location, sample result, and condition of the paint combinations and materials that may be disturbed by the intended renovation at this site. Under the tables we have listed where the paint surfaces fall in our lead surface classification system.
Air National Guard Reno, Lea Laney Wise Project No.21-142 OSHA Lead Renovation Survey – North Office Area of Building 76 June 16, 2021
1776 National Guard Way, Reno, NV 89502 Page 2 of 3
© WISE Consulting and Training, Inc. 2021
CONCLUSION and RECOMMENDATION
Because of the LBP level results on Tile as listed in the Table above, it is our recommendation that work disturbing those surfaces be conducted under the guidance of a site-specific Lead
Compliance Plan (Plan) based on the OSHA Lead in Construction standard (29 CFR 1926.62).
The Plan will typically indicate the procedures, engineering controls, training, and personal protective equipment to be used by workers when performing the lead task. If lead disturbance is conducted, we also recommend in independent, qualified consultant conduct confirmation wipe sampling to confirm that lead hazards were not present when the work was completed.
All other surface results were determined to have no lead presence, so it is our opinion that special procedures related to Lead are not required for those tested surfaces.
CLOSURE
It was not the intent of this study to find buried paint surfaces or to conduct excessive destructive means to find suspect lead components. It was the purpose to find and sample accessible suspect paint combinations and/or components, including multi-layered paints, in the area of intended renovation.
LBP SUMMARY DATA
Lead Content
Classification
Paint Film
Description
Paint Film Location XRF Result mg/cm²
Color Condition
Lead-Based Paint level results (LBP)
Glaze on
Tile
Baseboard Tile in
Bathrooms
9.9, 8.7, 9.7, 9.2 Tan Good
Lead-Based Paint level results (LBP)
Glaze on
Tile
Shower Tile in
Bathroom
2.7, 3.4, 3.6, 2.5 Tan
Speckled
Good
No Paint on
Drywall
Interior Walls 0.00,0.00,0.00, 0.00,0.00
White N/A
No Paint on
CMU
Interior Walls 0.00,0.00,0.00
0.00,0.00
White N/A
No Paint on
CMU
Exterior Walls 0.00,0.00,0.00, 0.00,0.00
Grey N/A
No Paint on
Metal
Exterior 0.00,0.00,0.00
0.00,0.00
Grey N/A
No Paint on
Metal
Bathroom 0.00,0.00,0.00
0.00
Blue N/A
No Paint on
Metal
Bathroom 0.00,0.00,0.00
0.00
Orange N/A
No Glaze on
Tile
Bathroom Floor 0.00,0.00,0.00, 0.00
Tan/
Brown
N/A
*Notes: Good - No significant deterioration (chipping peeling, oxidation); Deteriorated - Greater than 2 square feet of small components (trim) deteriorated; on interior surfaces greater than 10 percent; or greater than 10 square feet on exterior surfaces; NA - No or very low lead content, No Action recommended.
Air National Guard Reno, Lea Laney Wise Project No.21-142 OSHA Lead Renovation Survey – North Office Area of Building 76 June 16, 2021
1776 National Guard Way, Reno, NV 89502 Page 3 of 3
© WISE Consulting and Training, Inc. 2021
This report represents information pertaining to the specific sample locations and paint conditions at the time the survey was conducted. No other observations, guarantees, or warranties are either expressed or implied.
Thank you for the opportunity to be of service on this project. Please let us know if you have any questions on the report or how to comply with OSHA procedures.
Prepared By:
J. Tom Wise, President
EPA/NV Lead Risk Assessor #NV-R-108635-2
NV Environmental Manager #EM 1618