260215-BEAM-Mt_SAC_BID_SET_052726.pdf

PDF 5 MB Posted

Attached to
Prequalification - Buildings 2M, 2T, 9A and 69 Roofing Repairs Project
Solicitation number
2026-071
Issued by
Los Angeles County, California

About this file

This is a bid set document prepared by BEAM Professionals for Mt. San Antonio College, a California community college district located in Walnut, California. The project involves roofing repairs and partial replacements at four buildings (2M, 2T, 9A, and 69) to address deteriorated roofing systems and water intrusion issues. The scope of work includes selective demolition of existing modified bitumen roof membranes down to the structural deck, replacement with SikaShield modified bitumen systems or approved alternates, installation of new coverboard and insulation, replacement of parapet cap flashing, brick cap flashing, and retrofit drain kits. Building 2M requires complete roof system replacement, while Buildings 2T, 9A, and 69 involve field membrane preservation with selective component replacement. The total roof area across all buildings is approximately 97,453 square feet, subdivided into multiple designated zones (A1-A23 for Buildings 2M and 2T, A1 for Building 9A, and A1-A4 for Building 69). A mandatory job walk is scheduled for June 30, 2026, at 9:00 a.m., with prequalification applications due July 7, 2026, at 2:00 p.m. Only contractors receiving a Prequalification Approval Letter will be eligible to bid in the subsequent formal bidding phase.

Contractors must hold a current California Contractor's License classification C-39 (Roofing) and be Department of Industrial Relations registered. The District has established a three percent Disabled Veteran Business Enterprise (DVBE) participation goal and a Community Workforce Agreement requiring prevailing wage compliance, apprentice utilization up to 30 percent of the craft workforce, and a 30 percent local resident employment goal. Contractors must be manufacturer-certified applicators eligible to obtain 20-year full system warranties and 5-year applicator warranties. Prequalification requirements include financial capacity demonstrated through reviewed or audited financial statements (the lesser of ten times working capital or ten times net worth), minimum combined comprehensive single-limit liability insurance of $2,000,000, proof of bondability from an admitted California surety with an A- rating or better, and completion of at least two public works building projects within the past five years in California. Prequalification scoring uses a maximum of 86 points, with a minimum of 70 points required to qualify. Bid security of ten percent of the maximum bid amount will be required in the subsequent bidding phase.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FO

R

B

LU

E B

E A

M

LA

B E

LIN

G

O C

R

5/27/2026 2:29:09 PM

05/27/26

BID SET

Mt. San Antonio College

Mt. San Antonio College 1100 N Grand Ave.

Walnut, CA 91789

G-000

COVER SHEET

G -000

C O

V E

R S

H E

E T

B

ID

S E

T

PROJECT NUMBER: 260215

BLDG. ENVELOPE:

ATTN:

ADDRESS:

EMAIL:

PHONE:

BEAM PROFESSIONALS

GENE KESLER

10760 E 4TH ST.

RANCHO CUCAMONGA, CA 91730

GENE.KESLER@BEAMPROF.COM

(909) 987-0909

CLIENT:

ATTN:

ADDRESS:

EMAIL:

PHONE:

MT. SAN ANTONIO COLLEGE

DANIEL MADRIGAL

1100 N GRAND AVE.

WALNUT, CA 91789

DMADRIGAL27@MTSAC.EDU

(909) 756-4596

PROJECT LOCATION

BUILDING 69

PROJECT LOCATION

BUILDING 2M & 2T

PROJECT LOCATION

BUILDING 9A

SAN JOSE HILLS RD.

G R

AN

D

AVE.

MOUNTAIN

EER R

D.

W TEMPLE AVE.

B O

N

IT

A D

R

WALNUT AVE.

STADIUM W

Y.

2T 2M

9A

N

R A

N C

H O

C U

C

AM

O N

G A

, C A

9-

7-

KEY PLAN

DATE PROJECT NUMBER

CLIENT

DRAWING HISTORY

w w w .p bk .c om

PLAN TRUE

FO

R

B

LU

E B

E A

M

LA

B E

LIN

G

/O C

R

Plot Stamp:

1"

0"

NORTH:

DRAWN BY:

CHECKED BY:

5/27/2026 2:29:44 PM

B

ID

S

ET

G-001

GENERAL PROJECT

INFORMATION

05/27/26 260215

Mt. San Antonio College

M t.

Sa n

An to ni o

C ol le ge

N G ra nd

A ve

W al nu t, C

A

G -001

G

EN

ER

A

L PR

O

JEC

T IN

FO

R

M A

TIO

N

MF

GK

SHEET

NUMBER SHEET NAME

ARCHITECTURAL

G-000 COVER SHEET

ARCHITECTURAL

G-001 GENERAL PROJECT INFORMATION

A-301 BUILDINGS 2T & 2M - ROOF PLANS

A-302 BUILDING 9A - ROOF PLAN

A-303 BUILDING 69 - ROOF PLAN

A-322 ROOF DETAILS

ABBREVIATIONS AND LEGEND KEYS

REFER TO SCHEDULES AND LEGENDS FOR ADDITIONAL ABBREVIATIONS

REFER TO OTHER DISCIPLINES FOR ADDITIONAL ABBREVIATIONS

A ABV above ACOUS acoustical ACT acoustical ceiling tile AD area drain ADJ adjustable AFF above finished floor ALT alternate ALUM aluminum APPROX approximate ARCH architect / architectural

B B.O. bottom of BALC balcony BD board BET between BLDG building BLKG blocking BLW below BM beam BOT bottom BRKT bracket BULKHD bulkhead BUR built up roof

C C.G. corner guard CAB cabinet CALK caulking CDS cabinet design series CEM cement CER ceramic CJ control joint CLG ceiling CLOS closet CLR clear CO cased opening COL column CONC concrete CONT continous CPT carpet CT ceramic tile CTR center CW curtain wall

D DBL double DET detail DIA diameter DIM dimension DN down DR door DS down spout DW dishwasher DWG drawing

E E east EA each EIFS exterior insulation & finish system ELEC electric(al) ELEV elevation EMER emergency ENCL enclosure EOS edge of slab EQ equal EQUIP equipment ETR existing to remain EW each way EXP. JT. expansion joint EXST existing

F F.O. face of FA fire alarm FAP fire annunciuator panel FD floor drain

FE fire extinguisher FEC fire extinguisher cabinet FG finish group FH fire hydrant FHC fire hose cabinet FIN finish FLR floor FLUOR fluorescent FT foot or feet FUR furring

G GAL gallon GALV galvanized GB grab bar GC general contractor GL glass GND ground GWB gypsum wall board GYP gypsum

H H.W.H. hot water heater HC handicapped HDWD hardwood HDWR hardware HM hollow metal HORIZ horizontal HR hour HT height

I ID inner diameter INCAN incandescent INSUL insulation INT interior

J JAN janitor JST joist JT joint

L LAM laminate LAV lavatory LB pound(s) LDG landing LT light

M MAX maximum MECH mechanical MEMB membrane MFR manufacturer MIN minimum MISC miscellaneous MO masonry opening MTD mounted MTL metal

N N north NIC not in contract NO number NOM nominal NTS not to scale

O O.P. overflow pipe OA overall OC on center OD outside diameter OFF office OH opposite hand OPG opening OPP opposite

P PART partition PCT porcelain tile PERM perimeter PG paint grade PLAM plastic laminate PLAS plaster PLYWD plywood POLYISO polyisocyanurate PR pair PT paint PTD painted

R R riser RAD radius RCP reflected ceiling plan RD roof drain RE: refer REF refrigerator REINF reinforced REQD required RESIL resilient RM room RO rough opening RTU root top unit (mech)

S S south SAFB sound attenunation fiber batt SC scupper SCHED schedule SEAL sealant SECT section SF square foot SHT sheet SIM similar SPEC specification SQ square SS stainless steel STD standard STF storefront STL steel STOR storage

PARTIAL LIST OF APPLICABLE CODES

2025 California Administrative Code (CAC) ......................................................................... (Part 1, Title 24, CCR) 2025 California Building Code (CBC) ................................................................................... (Part 2, Title 24, CCR)

(2024 International Building Code Volumes 1 & 2 with 2025 California Amendments) 2025 California Electrical Code (CEC) .................................................................................. (Part 3, Title 24, CCR)

(2023 National Electrical Code 70 with 2025 California Amendments) 2025 California Mechanical Code (CMC) .............................................................................. (Part 4, Title 24, CCR)

(2024 IAPMO Uniform Mechanical Code with 2025 California Amendments) 2025 California Plumbing Code (CPC) .................................................................................. (Part 5, Title 24, CCR)

(2024 IAPMO Uniform Plumbing Code with 2025 California Amendments) 2025 California Energy Code (CEC) ...................................................................................... (Part 6, Title 24, CCR) 2025 California Fire Code (CFC) ............................................................................................ (Part 9, Title 24, CCR)

(2024 International Fire Code with 2025 California Amendments) 2025 California Existing Building Code (CEBC) .................................................................. (Part 10, Title 24, CCR)

(2024 International Existing Building Code with 2025 California Amendments) 2025 California Green Building Standards Code (CALGreen) ............................................ (Part 11, Title 24, CCR) 2025 California Referenced Standards Code ....................................................................... (Part 12, Title 24, CCR) Title 19 CCR, Public Safety, State Fire Marshal Regulations 2022 ASME A17.1/CSA B44-13 Safety Code For Elevators and Escalators (per 2025 CBC Part 2, Ch 35) Note: Cal/OSHA Elevator Unit enforces CCR Title 8 and uses the 2022 ASME A17.1 by adoption

PARTIAL LIST OF APPLICABLE STANDARDS

NFPA 13 .... Standard for the Installation of Sprinkler Systems (as amended) * ...................................... (2025 Edition) NFPA 14 .... Standard for the Installation of Standpipe and Hose Systems (as amended) * .................... (2024 Edition) NFPA 17 .... Standard for Dry Chemical Extinguishing Systems .............................................................. (2024 Edition) NFPA 17A... Standard for Wet Chemical Extinguishing Systems ............................................................. (2024 Edition) NFPA 20 ..... Standard for the Installation of Stationary Pumps for Fire Protection ................................... (2025 Edition) NFPA 22 .... Standard for Water Tanks for Private Fire Protection ........................................................... (2023 Edition) NFPA 24 .... Standard for the Installation of Private Fire Service Mains and Their Appurtenances

(as amended)*....................................................................................................................... (2025 Edition) NFPA 25 .... Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems with California Amendments.............................................................................................. (2026 Edition) NFPA 72 .... National Fire Alarm and Signaling Code (as amended) * ..................................................... (2025 Edition) NFPA 80 .... Fire Doors and Other Opening Protectives ........................................................................... (2025 Edition) NFPA 92 .... Standard for Smoke Control Systems ................................................................................... (2024 Edition) NFPA 253 .. Standard Method of Test for Critical Radiant Flux of Floor Covering Systems

Using a Radiant Heat Energy Source ................................................................................... (2023 Edition) NFPA 2001 Standard on Clean Agent Fire Extinguishing Systems (as amended) * .............................. (2025 Edition) ICC 300 ...... ICC Standard on Bleachers, Folding and Telescoping Seating and Grandstands ............... (2023 Edition) UL 300 ....... Standard for Fire Testing of Fire Extinguishing Systems for Protection of Commercial Cooking

Equipment—with Revisions through April 22, 2024....................................................... (2019 Edition 4) UL 464 ....... Audible Signal Appliances—with Revisions through April 28, 2023 .............................. (2016 Edition11) UL 521 ....... Heat Detectors for Fire Protective Signaling Systems—with Revisions through

October 24, 2025......................................................................................................... (2024 Edition 8) UL 1971 ..... Standard for Signaling Devices for the Hearing Impaired with Revisions through

February 15, 2024........................................................................................................ (2002 Edition 3)

* See CBC Chapter 35, Referenced Standards for State of California amendments to the NFPA Standards.

For a complete list of applicable NFPA standards refer to 2025 CBC (SFM) Chapter 35 and 2025 California Fire Code (CFC) Chapter 80.

CODES & STANDARDS

SCOPE:

BUILDINGS 2M & 2T:

-ROOF AREA A1-A23: REMOVE EXISTING MODIFIED BITUMEN ROOF MEMBRANE LAYERS DOWN TO

STRUCTURAL ROOF DECK. REPLACEMENT IN-KIND WITH SIKASHIELD MODIFIED BITUMEN SYSTEM TO MATCH EXISTING WITH NEW COVERBOARD. NEW PARAPET CAP FLASHING. NEW BRICK CAP FLASHING &

SEALANT. NEW RETROFIT DRAINS.

-ROOF AREAS B1-B4: MOD-BIT ROOF TO BE COATED. NEW PARAPET CAP FLASHING. NEW BRICK CAP

FLASHING & SEALANT. NEW RETROFIT DRAINS.

BUILDING 9A:

-ROOF AREA A1: REMOVE EXISTING MODIFIED BITUMEN ROOF MEMBRANE LAYERS AND INSULATION

DOWN TO STRUCTURAL ROOF DECK. REPLACEMENT IN-KIND WITH SIKASHIELD MODIFIED BITUMEN SYSTEM TO MATCH EXISTING WITH NEW COVERBOARD. NEW PARAPET CAP FLASHING. NEW BRICK CAP

FLASHING & SEALANT. NEW RETROFIT DRAINS.

BUILDING 69:

- ROOF AREAS A1, A2, A3 & A4: REMOVE EXISTING MODIFIED BITUMEN ROOF MEMBRANE LAYERS DOWN TO STRUCTURAL ROOF DECK. REPLACEMENT IN-KIND WITH SIKASHIELD MODIFIED BITUMEN SYSTEM TO MATCH EXISTING WITH NEW COVERBOARD. NEW PARAPET CAP FLASHING. NEW BRICK CAP FLASHING &

SEALANT. NEW RETROFIT DRAINS.

SCOPE OF WORK

N.T.S.1 VICINITY MAP

No. Description Date

R.T.U R.T.U

R.T.U.

R.T.U.

B1

A16

S S

S S

S S

B2

B3 B4

R.T.U R.T.U

RIDGE

RIDGE

RIDGE

RIDGE

RIDGE

SL.

SL.

SL.

SL.

SL.

SL.

A3

A8

A4

A5

A9

A10

A2

A11

A12 A13

A14

A15

A18

A17 A22

A21

A20

A19

A6

A7

A1

A-322

A-322

A-322

A-322

A-322

A-322

A-322

TYP.

44 4

5 5

3 3

TYP.

3/A-322

A-322

A-322

A-322

A-322

A-322

A-322

A-322

A-322

A-322

A-322

A-322

A-322

A-322 2

A-322

A-322

A-322

A-322

A-322 15 A-322

A-322

A-322

A-322

R.T.U

R.T.U. R.T.U.

EJ

EJ

A23

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

N.I.C.

A-322

1. CONTRACTOR SHALL VISIT SITE TO ASCERTAIN EXACT EXISTING CONDITIONS AND

COMPONENTS RELATED TO THE WORK DESCRIBED BY THESE DOCUMENTS. AFTER AWARD OF

THE CONTRACT, CHANGE ORDER REQUEST FOR ADDITIONAL MONEY SHALL NOT BE APPROVED

IF THE WORK COULD HAVE BEEN ANTICIPATED DURING THE SITE VISIT BY THE CONTRACTOR,

ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH ACCEPTED MANUFACTURER'S PRINTED

INSTRUCTIONS AND WARRANTY REQUIREMENTS.

2. DIMENSIONS, DETAILS, EQUIPMENT SIZE AND LOCATION SHOWN IN THESE CONSTRUCTION

DOCUMENTS ARE FOR CONVEYANCE OF DESIGN INTENT ONLY. EXACT SIZE, LOCATION, TYPE OF MATERIAL AND TYPE OF CONSTRUCTION OF EXISTING CONDITIONS ARE THE RESPONSIBILITY OF

THE CONTRACTOR TO ASCERTAIN AND CONFIRM.

3. INDICATED ROOF HEIGHTS ARE GENERAL IN NATURE.

4. REFER TO NOMENCLATURE FOR TYPE OF ROOF SYSTEM. AREAS ARE MARKED WITH

DESIGNATED LETTER ON ROOF PLAN.

5. NOTE THAT THE DETAILS DRAWN ARE GENERIC IN NATURE AND ARE NOT NECESSARILY

LOCATED AND KEYED TO THE ROOF PLANS.

6. REMOVE ALL ABANDONED EQUIPMENT IDENTIFIED ON SITE AND AS SHOWN OTHERWISE ON

THESE DOCUMENTS.

7. ALL NEW CRICKETS AND TAPERED INSULATION SHALL BE INSTALLED WITH A FINISHED 1/4" PER

FOOT MIN. SLOPE. CRICKET THE UP SLOPE SIDE OF ALL SQUARE CURBS AND PROJECTIONS

OVER 20' IN WIDTH.

8. REPLACE ROTTED AND / OR OTHERWISE DETERIORATED ROOF DECK MATERIALS (AS

APPLICABLE) WITH LIKE MATERIAL AND THICKNESS.

9. REPLACE ROTTEN AND / OR OTHERWISE DETERIORATED WOOD NAILER MATERIAL WITH NEW

LIKE MATERIAL AND THICKNESS.

10. AS APPLICABLE, ALL HVAC AND / OR DX UNITS, ELECTRICAL TRANSFORMERS, ROOF TOP

EQUIPMENT, ETC. THAT ARE ON SLEEPERS SHALL BE DISCONNECTED / REMOVED, RAISED, AND

PLACED ON NEW CURBED PLATFORMS AS DETAILED AND REINSTALLED / RECONNECTED. ALL

CURB MOUNTED HVAC UNITS, EQUIPMENT, ETC. SHALL HAVE A MINIMUM 10" CURB HEIGHT AND

ARE TO BE RAISED AS REQUIRED.

11. WORK TO ANY UTILITY CONDUIT OR PIPE SHALL BE PERFORMED BY SPECIFIC LICENSED

SUBCONTRACTORS SPECIALIZING IN HVAC, PLUMBING AND ELECTRICAL WORK. PERMITS AND

INSPECTIONS ARE REQUIRED. REROUTE AND / OR MODIFY UTILITY CONDUIT OR PIPE AS

REQUIRED TO BE INSTALLED AS DETAILED.

12. PROVIDE A "MERCURY" GAS LINE TEST (COORDINATE WITH OWNER AND ARCHITECT FOR

WITNESS OF TEST). REPAIR ANY FOUND LEAKS AND RETEST AS REQUIRED.

13. UNLESS INDICATED OTHERWISE ON THE CONSTRUCTION DOCUMENTS, REPLACE AND RAISE

ALL EXISTING EXPANSION JOINTS / AREA DIVIDERS / CURB MOUNTED EQUIPMENT / SKYLIGHTS

(AS APPLICABLE) A MIN. 10" ABOVE ROOF DECK.

14. ALL SOIL STACK FLASHING SHALL BE A MIN. 10" ABOVE FINISHED ROOF SURFACE. COUPLE

PVC PIPE ABOVE DECK AND COUPLE CAST IRON PIPE BELOW DECK.

15. ALL PIPING/ CONDUITS/ ETC. SHALL BE A MIN. 10" ABOVE ROOF SURFACE, NEW AND EXISTING.

PROVIDE PORTABLE PIPE HANGERS WITH PROTECTION PADS AS SPECIFIED. RAISE EXISTING

PIPING/ CONDUIT/ ETC. AS REQUIRED. MEP CONTRACTORS SHALL PROVIDE SUPPORTS FOR

UTILITY LINES.

16. PROVIDE SHEET METAL HOODED (WITH METAL FACE CLOSURE) CAPS, WOOD CURB, BOX

COVER AT ALL GAS AND WATER PIPE ROOF PENETRATIONS AS DETAILED. PROVIDE POSITIVE

SLOPE AWAY FROM FACE COVER.

17. PROVIDE WALKWAY PROTECTION PADS AS SPECIFIED AROUND ALL ROOF HATCHES, HVAC

ROOFTOP UNITS, DOORS THAT OPEN ONTO ROOF AND AT TOP AND BOTTOM OF ALL ROOF TOP

ACCESS LOCATIONS.

18. FALL PROTECTION DEVICES SHOWN ON THIS ROOF PLAN ARE FOR REFERENCE ONLY TO

IDENTIFY LOCATION OF FLASHING/WATERPROOFING DETAILS. REFERENCE STRUCTURAL

DRAWINGS FOR CONNECTION AND LAYOUT INFORMATION.

19. LIGHTING PROTECTION DEVICES SHOWN ON THIS ROOF PLAN ARE FOR REFERENCE ONLY TO

INDENTIFY LOCATIONS OF FLASHING/WATERPROOFING DETAILS.

20. INSTALL NEW SPLASH PAN AT ALL LOCATIONS WHERE ROOF DRAINAGE DISCHARGES ONTO

ROOF AREA. INSTALL NEW SPLASH BLOCKS WHERE ROOF DRAINAGE DISCHARGES ON GROUND.

21. ISOLATE ALL HEAT PIPES / FLUES AS DETAILED AND RECOMMENDED AND OUTLINED IN THE

NRCA MANUAL FOR HOT STACK FLASHING AND AS DETAILED.

22. ALL OUTSIDE AIR INTAKES SHALL BE COVERED TO ELIMINATE ODORS AND FUMES FROM

ENTERING INTO THE BUILDING DURING CONSTRUCTION WORK.

23. AFTER SUBSTANTIAL COMPLETION, THE GENERAL CONTRACTOR SHALL EXAMINE AND CLEAN

NEW DRAIN LINES AND NEW AND EXISTING (AS APPLICABLE) GUTTERS OF DEBRIS AND

BLOCKAGE, FLUSH WITH WATER TO ENSURE THAT DRAINS AND GUTTERS FLOW FREELY.

24. OWNER WILL VERIFY PROPER OPERATION OF ALL ROOF TOP EQUIPMENT BEFORE AND AFTER

THE PROJECT. CONTRACTOR SHALL BE RESPONSIBLE FOR IDENTIFYING ALL INOPERABLE

EQUIPMENT PRIOR TO RELEASE OF RETAINAGE.

25. PRIOR TO COMMENCEMENT OF WORK, COORDINATE WALK OF ENTIRE ROOF WITH ROOFING

MANUFACTURER'S TECHNICAL REPRESENTATIVE TO IDENTIFY AND LOCATE ALL AREAS OF HIGH

SLOPE OR OTHER CONDITIONS WHICH MIGHT REQUIRE SPECIAL PROCEDURES FOR SYSTEM

ATTACHMENT.

26. REFER TO MEP DRAWINGS FOR SIZE AND LOCATION OF DECK PENETRATIONS AND ROOF TOP

EQUIPMENT.

27. REFER TO GENERAL DETAILS FOR TYPICAL SPLASH PAN, ROOF DRAIN AND OVERFLOW DRAIN

DETAILS.

28. REPLACE ALL RUSTED AND / OR DETERIORATED EXISTING METAL VENT FLASHING AND FLUES.

29. GENERAL CONTRACTOR TO ENSURE ALL ROOFTOP PENETRATIONS (SOIL STACKS, VENTS,

ETC.) ARE INSTALLED MIN. 4'-0" FROM OTHER DECK PENETRATIONS, RISE WALLS, AND ROOF

EDGE. MECHANICAL EQUIPMENT TO BE LOCATED MIN. 10'-0" FROM PERIMETER EDGE AND NO

CLOSER THAN 4'-0" FROM RISE WALLS, OR ANY OTHER ROOF PENETRATION.

30. LOCATE PERIMETER DRAINS MAX. 6'-0" FROM EDGE TYPICAL UNLESS SHOWN OTHERWISE.

(GENERAL CONTRACTOR TO COORDINATE WITH ROOFING AND PLUMBING CONTRACTOR.)

31. THROUGH WALL BASE FLASHING MIN. HEIGHT 10" AND MAX. HEIGHT 20" FROM FINISH DECK. DO

NOT STEP THROUGH WALL FLASHING CLOSER THAN 5'-0" FROM CORNERS.

32. GENERAL CONTRACTOR SHALL COORDINATE LOCATION AND ORIENTATION OF ROOF HATCH

AND ACCESS LADDER.

33. GENERAL CONTRACTOR SHALL COORDINATE ALL TOP OF STEEL TO TOP OF BLOCKING AND

SUBSTRATE BOARD DIMENSIONS IN FIELD PRIOR TO ORDERING MATERIALS. NO ADDITIONAL

COMPENSATION WILL BE GRANTED FOR FAILURE TO COORDINATE THESE DIMENSIONS.

34. GENERAL CONTRACTOR SHALL VERIFY ROOF SLOPES WILL PROPERLY DRAIN AS SHOWN.

TAPERED INSULATION HATCHING SHOWN IS NOT INTENDED TO ILLUSTRATE THE ENTIRE LIMITS

OF TAPERED INSULATION. ROOF AREAS NOT SLOPED BY STRUCTURE SHALL BE SLOPED WITH

TAPERED INSULATION TO ACHIEVE PROPER DRAINAGE.

35. PROVIDE ONE WAY MOISTURE VENTS AT ALL LIGHTWEIGHT CONCRETE OR GYPSUM OVER

POUR AREAS AS RECOMMENDED BY THE ROOFING SYSTEM MANUFACTURER.

36. PAINT ALL EXISTING GAS PIPE TO REMAIN.

37. PROVIDE RETROFIT DRAIN KIT FOR EACH EXISTING ROOF DRAIN. RE: SPECS.

38. ALL ROOFING WORK SHALL OCCUR IN SUCH A MANNER AS NOT TO VOID ANY EXISTING ROOF

WARRANTIES. CONTRACTOR TO CONTACT ROOFING MANUFACTURER PRIOR TO COMMENCING

THE WORK. NO EXCEPTIONS.

39. FALL PROTECTION DEVICES SHOWN ON THIS ROOF PLAN ARE FOR REFERENCE ONLY TO

IDENTIFY LOCATIONS OF FLASHING/WATERPROOFING DETAILS. REFERENCE STRUCTURAL

DRAWINGS FOR CONNECTION AND LAYOUT INFORMATION.

40. LIGHTENING PROTECTION DEVICES SHOWN ON THIS ROOF PLAN ARE FOR REFERENCE ONLY

TO IDENTIFY LOCATIONS OF FLASHING/WATERPROOFING DETAILS

CURB MOUNTED VENT

(RE: & )

CURB MOUNTED

AC

ROOF HATCH

SKYLIGHTS

SCUPPER

GUTTER

DOWNSPOUT

RIDGE LINE

EXISTING AREA

TO REMAIN -NIC

METAL ROOF (N.I.C.)

A1 ROOF AREA

DESIGNATION

S

G

DS

R.T.U.

SL

NEW TAPERED

INSULATION / CRICKET

(RE: )

EXIST. ROOF DRAIN

W/ OVERFLOW

EXIST. ROOF DRAIN

VENT THROUGH ROOF

(RE: & )

CONDENSING UNITC.U.

OF

WALKPADS

(RE: )

6 / A-322

5 / A-322

14 / A-322 20 / A-322

8 / A-322 17 / A-322

N.I.C.

(E) LIGHTWEIGHT CONCRETE IN-FILL

(E) 1" RIGID INSULATION

(N) MODIFIED BITUMEN

BUILT-UP ROOF (RE: SPECS)

(E) METAL DECK

3/

4" 1"

(N) 1/4" DENSDECK (RE: SPECS)

ROOF ACCESS DOOR - RE: (RE: SPECS)

ROOF HATCH

EXHAUST FAN DUCT PENETRATION

(E) MODIFIED BITUMEN ROOFING TO BE REPLACED IN-KIND WITH NEW

(RE: NOMENCLATURE 'A' & RE: SPECS)

(N) MOD-BIT COMPATIBLE COATING OVER (E) MODIFIED BITUMEN

ROOFING

13 / A-322

(E) LIGHTWEIGHT CONCRETE IN-FILL

(E) 1" RIGID INSULATION

(E) MODIFIED BITUMEN

BUILT-UP ROOF (RE: SPECS)

(E) METAL DECK

3/

4" 1"

(N) SURFACE COATING (RE: SPECS)

N

R A

N C

H O

C U

C

AM

O N

G A

, C A

9-

7-

KEY PLAN

DATE PROJECT NUMBER

CLIENT

DRAWING HISTORY

w w w .p bk .c om

PLAN TRUE

FO

R

B

LU

E B

E A

M

LA

B E

LIN

G

/O C

R

Plot Stamp:

1"

0"

NORTH:

DRAWN BY:

CHECKED BY:

5/27/2026 2:59:46 PM

B

ID

S

ET

A-301

BUILDINGS 2T & 2M -

ROOF PLANS

05/27/26 260215

Mt. San Antonio College

M t.

Sa n

An to ni o

C ol le ge

N G ra nd

A ve

W al nu t, C

A

A -301

B U

ILD

IN

G S 2T &

2M -R

O O

F PLA

N

S

Author

Checker

1/16" = 1'-0"6 BUILDINGS 2T & 2M ROOF PLANS

N.T.S.

ROOF GENERAL NOTES

N.T.S.

LEGEND

MT. SAN ANTONIO ROOF SCHEDULE

MARK APPROX. SQ. FT. EXISTING NOMENCLATURE

PROPOSED

NOMENCLATURE Comments

A1 4,968 SF MODIFIED BITUMEN ROOFING 27/A-301

A2 2,108 SF MODIFIED BITUMEN ROOFING 27/A-301

A3 2,355 SF MODIFIED BITUMEN ROOFING 27/A-301

A4 32 SF MODIFIED BITUMEN ROOFING 27/A-301

A5 32 SF MODIFIED BITUMEN ROOFING 27/A-301

A6 336 SF MODIFIED BITUMEN ROOFING 27/A-301

A7 365 SF MODIFIED BITUMEN ROOFING 27/A-301

A8 398 SF MODIFIED BITUMEN ROOFING 27/A-301

A9 2,043 SF MODIFIED BITUMEN ROOFING 27/A-301

A10 5,898 SF MODIFIED BITUMEN ROOFING 27/A-301

A11 1,409 SF MODIFIED BITUMEN ROOFING 27/A-301

A12 1,364 SF MODIFIED BITUMEN ROOFING 27/A-301

A13 634 SF MODIFIED BITUMEN ROOFING 27/A-301

A14 9,380 SF MODIFIED BITUMEN ROOFING 27/A-301

A15 1,012 SF MODIFIED BITUMEN ROOFING 27/A-301

A16 4,672 SF MODIFIED BITUMEN ROOFING 27/A-301

A17 669 SF MODIFIED BITUMEN ROOFING 27/A-301

A18 3,178 SF MODIFIED BITUMEN ROOFING 27/A-301

A19 3,553 SF MODIFIED BITUMEN ROOFING 27/A-301

A20 8,310 SF MODIFIED BITUMEN ROOFING 27/A-301

A21 665 SF MODIFIED BITUMEN ROOFING 27/A-301

A22 2,849 SF MODIFIED BITUMEN ROOFING 27/A-301

A23 2,341 SF MODIFIED BITUMEN ROOFING 27/A-301

B1 3,601 SF MODIFIED BITUMEN ROOFING 28/A-301

B2 1,000 SF MODIFIED BITUMEN ROOFING 28/A-301

B3 697 SF MODIFIED BITUMEN ROOFING 28/A-301

B4 704 SF MODIFIED BITUMEN ROOFING 28/A-301

Grand total 64,575 SF

N.T.S.27 NOMENCLATURE 'A'

N.T.S.20 ROOFING - KEYNOTES

N.T.S.28 NOMENCLATURE 'B'

BUILDING 2T BUILDING 2M

OFOFOFOF

OFOFOFOF

ROOF HATCH

EXHAUST FAN DUCT

(E) MODIFIED BITUMEN ROOFING TO BE REPLACED IN-KIND WITH NEW

(RE: NOMENCLATURE 'A' & RE: SPECS)

1. CONTRACTOR SHALL VISIT SITE TO ASCERTAIN EXACT EXISTING CONDITIONS AND

COMPONENTS RELATED TO THE WORK DESCRIBED BY THESE DOCUMENTS. AFTER AWARD OF

THE CONTRACT, CHANGE ORDER REQUEST FOR ADDITIONAL MONEY SHALL NOT BE APPROVED

IF THE WORK COULD HAVE BEEN ANTICIPATED DURING THE SITE VISIT BY THE CONTRACTOR,

ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH ACCEPTED MANUFACTURER'S PRINTED

INSTRUCTIONS AND WARRANTY REQUIREMENTS.

2. DIMENSIONS, DETAILS, EQUIPMENT SIZE AND LOCATION SHOWN IN THESE CONSTRUCTION

DOCUMENTS ARE FOR CONVEYANCE OF DESIGN INTENT ONLY. EXACT SIZE, LOCATION, TYPE OF MATERIAL AND TYPE OF CONSTRUCTION OF EXISTING CONDITIONS ARE THE RESPONSIBILITY OF

THE CONTRACTOR TO ASCERTAIN AND CONFIRM.

3. INDICATED ROOF HEIGHTS ARE GENERAL IN NATURE.

4. REFER TO NOMENCLATURE FOR TYPE OF ROOF SYSTEM. AREAS ARE MARKED WITH

DESIGNATED LETTER ON ROOF PLAN.

5. NOTE THAT THE DETAILS DRAWN ARE GENERIC IN NATURE AND ARE NOT NECESSARILY

LOCATED AND KEYED TO THE ROOF PLANS.

6. REMOVE ALL ABANDONED EQUIPMENT IDENTIFIED ON SITE AND AS SHOWN OTHERWISE ON

THESE DOCUMENTS.

7. ALL NEW CRICKETS AND TAPERED INSULATION SHALL BE INSTALLED WITH A FINISHED 1/4" PER

FOOT MIN. SLOPE. CRICKET THE UP SLOPE SIDE OF ALL SQUARE CURBS AND PROJECTIONS

OVER 20' IN WIDTH.

8. REPLACE ROTTED AND / OR OTHERWISE DETERIORATED ROOF DECK MATERIALS (AS

APPLICABLE) WITH LIKE MATERIAL AND THICKNESS.

9. REPLACE ROTTEN AND / OR OTHERWISE DETERIORATED WOOD NAILER MATERIAL WITH NEW

LIKE MATERIAL AND THICKNESS.

10. AS APPLICABLE, ALL HVAC AND / OR DX UNITS, ELECTRICAL TRANSFORMERS, ROOF TOP

EQUIPMENT, ETC. THAT ARE ON SLEEPERS SHALL BE DISCONNECTED / REMOVED, RAISED, AND

PLACED ON NEW CURBED PLATFORMS AS DETAILED AND REINSTALLED / RECONNECTED. ALL

CURB MOUNTED HVAC UNITS, EQUIPMENT, ETC. SHALL HAVE A MINIMUM 10" CURB HEIGHT AND

ARE TO BE RAISED AS REQUIRED.

11. WORK TO ANY UTILITY CONDUIT OR PIPE SHALL BE PERFORMED BY SPECIFIC LICENSED

SUBCONTRACTORS SPECIALIZING IN HVAC, PLUMBING AND ELECTRICAL WORK. PERMITS AND

INSPECTIONS ARE REQUIRED. REROUTE AND / OR MODIFY UTILITY CONDUIT OR PIPE AS

REQUIRED TO BE INSTALLED AS DETAILED.

12. PROVIDE A "MERCURY" GAS LINE TEST (COORDINATE WITH OWNER AND ARCHITECT FOR

WITNESS OF TEST). REPAIR ANY FOUND LEAKS AND RETEST AS REQUIRED.

13. UNLESS INDICATED OTHERWISE ON THE CONSTRUCTION DOCUMENTS, REPLACE AND RAISE

ALL EXISTING EXPANSION JOINTS / AREA DIVIDERS / CURB MOUNTED EQUIPMENT / SKYLIGHTS

(AS APPLICABLE) A MIN. 10" ABOVE ROOF DECK.

14. ALL SOIL STACK FLASHING SHALL BE A MIN. 10" ABOVE FINISHED ROOF SURFACE. COUPLE

PVC PIPE ABOVE DECK AND COUPLE CAST IRON PIPE BELOW DECK.

15. ALL PIPING/ CONDUITS/ ETC. SHALL BE A MIN. 10" ABOVE ROOF SURFACE, NEW AND EXISTING.

PROVIDE PORTABLE PIPE HANGERS WITH PROTECTION PADS AS SPECIFIED. RAISE EXISTING

PIPING/ CONDUIT/ ETC. AS REQUIRED. MEP CONTRACTORS SHALL PROVIDE SUPPORTS FOR

UTILITY LINES.

16. PROVIDE SHEET METAL HOODED (WITH METAL FACE CLOSURE) CAPS, WOOD CURB, BOX

COVER AT ALL GAS AND WATER PIPE ROOF PENETRATIONS AS DETAILED. PROVIDE POSITIVE

SLOPE AWAY FROM FACE COVER.

17. PROVIDE WALKWAY PROTECTION PADS AS SPECIFIED AROUND ALL ROOF HATCHES, HVAC

ROOFTOP UNITS, DOORS THAT OPEN ONTO ROOF AND AT TOP AND BOTTOM OF ALL ROOF TOP

ACCESS LOCATIONS.

18. FALL PROTECTION DEVICES SHOWN ON THIS ROOF PLAN ARE FOR REFERENCE ONLY TO

IDENTIFY LOCATION OF FLASHING/WATERPROOFING DETAILS. REFERENCE STRUCTURAL

DRAWINGS FOR CONNECTION AND LAYOUT INFORMATION.

19. LIGHTING PROTECTION DEVICES SHOWN ON THIS ROOF PLAN ARE FOR REFERENCE ONLY TO

INDENTIFY LOCATIONS OF FLASHING/WATERPROOFING DETAILS.

20. INSTALL NEW SPLASH PAN AT ALL LOCATIONS WHERE ROOF DRAINAGE DISCHARGES ONTO

ROOF AREA. INSTALL NEW SPLASH BLOCKS WHERE ROOF DRAINAGE DISCHARGES ON GROUND.

21. ISOLATE ALL HEAT PIPES / FLUES AS DETAILED AND RECOMMENDED AND OUTLINED IN THE

NRCA MANUAL FOR HOT STACK FLASHING AND AS DETAILED.

22. ALL OUTSIDE AIR INTAKES SHALL BE COVERED TO ELIMINATE ODORS AND FUMES FROM

ENTERING INTO THE BUILDING DURING CONSTRUCTION WORK.

23. AFTER SUBSTANTIAL COMPLETION, THE GENERAL CONTRACTOR SHALL EXAMINE AND CLEAN

NEW DRAIN LINES AND NEW AND EXISTING (AS APPLICABLE) GUTTERS OF DEBRIS AND

BLOCKAGE, FLUSH WITH WATER TO ENSURE THAT DRAINS AND GUTTERS FLOW FREELY.

24. OWNER WILL VERIFY PROPER OPERATION OF ALL ROOF TOP EQUIPMENT BEFORE AND AFTER

THE PROJECT. CONTRACTOR SHALL BE RESPONSIBLE FOR IDENTIFYING ALL INOPERABLE

EQUIPMENT PRIOR TO RELEASE OF RETAINAGE.

25. PRIOR TO COMMENCEMENT OF WORK, COORDINATE WALK OF ENTIRE ROOF WITH ROOFING

MANUFACTURER'S TECHNICAL REPRESENTATIVE TO IDENTIFY AND LOCATE ALL AREAS OF HIGH

SLOPE OR OTHER CONDITIONS WHICH MIGHT REQUIRE SPECIAL PROCEDURES FOR SYSTEM

ATTACHMENT.

26. REFER TO MEP DRAWINGS FOR SIZE AND LOCATION OF DECK PENETRATIONS AND ROOF TOP

EQUIPMENT.

27. REFER TO GENERAL DETAILS FOR TYPICAL SPLASH PAN, ROOF DRAIN AND OVERFLOW DRAIN

DETAILS.

28. REPLACE ALL RUSTED AND / OR DETERIORATED EXISTING METAL VENT FLASHING AND FLUES.

29. GENERAL CONTRACTOR TO ENSURE ALL ROOFTOP PENETRATIONS (SOIL STACKS, VENTS,

ETC.) ARE INSTALLED MIN. 4'-0" FROM OTHER DECK PENETRATIONS, RISE WALLS, AND ROOF

EDGE. MECHANICAL EQUIPMENT TO BE LOCATED MIN. 10'-0" FROM PERIMETER EDGE AND NO

CLOSER THAN 4'-0" FROM RISE WALLS, OR ANY OTHER ROOF PENETRATION.

30. LOCATE PERIMETER DRAINS MAX. 6'-0" FROM EDGE TYPICAL UNLESS SHOWN OTHERWISE.

(GENERAL CONTRACTOR TO COORDINATE WITH ROOFING AND PLUMBING CONTRACTOR.)

31. THROUGH WALL BASE FLASHING MIN. HEIGHT 10" AND MAX. HEIGHT 20" FROM FINISH DECK. DO

NOT STEP THROUGH WALL FLASHING CLOSER THAN 5'-0" FROM CORNERS.

32. GENERAL CONTRACTOR SHALL COORDINATE LOCATION AND ORIENTATION OF ROOF HATCH

AND ACCESS LADDER.

33. GENERAL CONTRACTOR SHALL COORDINATE ALL TOP OF STEEL TO TOP OF BLOCKING AND

SUBSTRATE BOARD DIMENSIONS IN FIELD PRIOR TO ORDERING MATERIALS. NO ADDITIONAL

COMPENSATION WILL BE GRANTED FOR FAILURE TO COORDINATE THESE DIMENSIONS.

34. GENERAL CONTRACTOR SHALL VERIFY ROOF SLOPES WILL PROPERLY DRAIN AS SHOWN.

TAPERED INSULATION HATCHING SHOWN IS NOT INTENDED TO ILLUSTRATE THE ENTIRE LIMITS

OF TAPERED INSULATION. ROOF AREAS NOT SLOPED BY STRUCTURE SHALL BE SLOPED WITH

TAPERED INSULATION TO ACHIEVE PROPER DRAINAGE.

35. PROVIDE ONE WAY MOISTURE VENTS AT ALL LIGHTWEIGHT CONCRETE OR GYPSUM OVER

POUR AREAS AS RECOMMENDED BY THE ROOFING SYSTEM MANUFACTURER.

36. PAINT ALL EXISTING GAS PIPE TO REMAIN.

37. PROVIDE RETROFIT DRAIN KIT FOR EACH EXISTING ROOF DRAIN. RE: SPECS.

38. ALL ROOFING WORK SHALL OCCUR IN SUCH A MANNER AS NOT TO VOID ANY EXISTING ROOF

WARRANTIES. CONTRACTOR TO CONTACT ROOFING MANUFACTURER PRIOR TO COMMENCING

THE WORK. NO EXCEPTIONS.

39. FALL PROTECTION DEVICES SHOWN ON THIS ROOF PLAN ARE FOR REFERENCE ONLY TO

IDENTIFY LOCATIONS OF FLASHING/WATERPROOFING DETAILS. REFERENCE STRUCTURAL

DRAWINGS FOR CONNECTION AND LAYOUT INFORMATION.

40. LIGHTENING PROTECTION DEVICES SHOWN ON THIS ROOF PLAN ARE FOR REFERENCE ONLY

TO IDENTIFY LOCATIONS OF FLASHING/WATERPROOFING DETAILS

CURB MOUNTED VENT

(RE: & )

CURB MOUNTED

AC

ROOF HATCH

SKYLIGHTS

SCUPPER

GUTTER

DOWNSPOUT

RIDGE LINE

EXISTING AREA

TO REMAIN -NIC

METAL ROOF (N.I.C.)

A1 ROOF AREA

DESIGNATION

S

G

DS

R.T.U.

SL

NEW TAPERED

INSULATION / CRICKET

(RE: )

EXIST. ROOF DRAIN

W/ OVERFLOW

EXIST. ROOF DRAIN

VENT THROUGH ROOF

(RE: & )

CONDENSING UNITC.U.

OF

WALKPADS

(RE: )

6 / A-322

5 / A-322

14 / A-322 20 / A-322

8 / A-322 17 / A-322

N.I.C.

RIDGE

A-322

A-322

A-322

A-322

A-322

A-322

R.T.U.

TYP.

A-322

TYP.

A-322

A-322

(E) LIGHTWEIGHT CONCRETE IN-FILL

(E) 1" RIGID INSULATION

(N) MODIFIED BITUMEN

BUILT-UP ROOF (RE: SPECS)

(E) METAL DECK

3/

4" 1"

(N) 1/4" DENSDECK (RE: SPECS)

AREA APPROX.

SQ. FT.

EXISTING NOMENCLATURE PROPOSED

NOMENCLATURE

COMMENTS

A1 24,146 26/A-302MODIFIED BITUMEN ROOF

TOTAL 24,146

N

R A

N C

H O

C U

C

AM

O N

G A

, C A

9-

7-

KEY PLAN

DATE PROJECT NUMBER

CLIENT

DRAWING HISTORY

w w w .p bk .c om

PLAN TRUE

FO

R

B

LU

E B

E A

M

LA

B E

LIN

G

/O C

R

Plot Stamp:

1"

0"

NORTH:

DRAWN BY:

CHECKED BY:

5/27/2026 2:46:35 PM

B

ID

S

ET

A-302

BUILDING 9A - ROOF

PLAN

05/27/26 260215

Mt. San Antonio College

M t.

Sa n

An to ni o

C ol le ge

N G ra nd

A ve

W al nu t, C

A

A -302

B U

ILD

IN

G 9A

-R O

O

F PLA

N

Author

Checker

N.T.S.27 ROOFING - KEYNOTES

N.T.S.

ROOF GENERAL NOTES

N.T.S.

LEGEND

1/8" = 1'-0"6 BUILDING 9A ROOF PLAN

N.T.S.26 NOMENCLATURE 'A'

A1

N.T.S.19 ROOF AREA

R.T .U

R.T .U

C.U.

C.U.

R.T.U.

R.T.U.

R.T.U.

R.T.U.

A-322

A-322

A-322

C.U.

1 1

A-322

A-322

A-322

A-322

A-322

A-322

A-322

A-322

A-322

A-322

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

1. CONTRACTOR SHALL VISIT SITE TO ASCERTAIN EXACT EXISTING CONDITIONS AND

COMPONENTS RELATED TO THE WORK DESCRIBED BY THESE DOCUMENTS. AFTER AWARD OF

THE CONTRACT, CHANGE ORDER REQUEST FOR ADDITIONAL MONEY SHALL NOT BE APPROVED

IF THE WORK COULD HAVE BEEN ANTICIPATED DURING THE SITE VISIT BY THE CONTRACTOR,

ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH ACCEPTED MANUFACTURER'S PRINTED

INSTRUCTIONS AND WARRANTY REQUIREMENTS.

2. DIMENSIONS, DETAILS, EQUIPMENT SIZE AND LOCATION SHOWN IN THESE CONSTRUCTION

DOCUMENTS ARE FOR CONVEYANCE OF DESIGN INTENT ONLY. EXACT SIZE, LOCATION, TYPE OF MATERIAL AND TYPE OF CONSTRUCTION OF EXISTING CONDITIONS ARE THE RESPONSIBILITY OF

THE CONTRACTOR TO ASCERTAIN AND CONFIRM.

3. INDICATED ROOF HEIGHTS ARE GENERAL IN NATURE.

4. REFER TO NOMENCLATURE FOR TYPE OF ROOF SYSTEM. AREAS ARE MARKED WITH

DESIGNATED LETTER ON ROOF PLAN.

5. NOTE THAT THE DETAILS DRAWN ARE GENERIC IN NATURE AND ARE NOT NECESSARILY

LOCATED AND KEYED TO THE ROOF PLANS.

6. REMOVE ALL ABANDONED EQUIPMENT IDENTIFIED ON SITE AND AS SHOWN OTHERWISE ON

THESE DOCUMENTS.

7. ALL NEW CRICKETS AND TAPERED INSULATION SHALL BE INSTALLED WITH A FINISHED 1/4" PER

FOOT MIN. SLOPE. CRICKET THE UP SLOPE SIDE OF ALL SQUARE CURBS AND PROJECTIONS

OVER 20' IN WIDTH.

8. REPLACE ROTTED AND / OR OTHERWISE DETERIORATED ROOF DECK MATERIALS (AS

APPLICABLE) WITH LIKE MATERIAL AND THICKNESS.

9. REPLACE ROTTEN AND / OR OTHERWISE DETERIORATED WOOD NAILER MATERIAL WITH NEW

LIKE MATERIAL AND THICKNESS.

10. AS APPLICABLE, ALL HVAC AND / OR DX UNITS, ELECTRICAL TRANSFORMERS, ROOF TOP

EQUIPMENT, ETC. THAT ARE ON SLEEPERS SHALL BE DISCONNECTED / REMOVED, RAISED, AND

PLACED ON NEW CURBED PLATFORMS AS DETAILED AND REINSTALLED / RECONNECTED. ALL

CURB MOUNTED HVAC UNITS, EQUIPMENT, ETC. SHALL HAVE A MINIMUM 10" CURB HEIGHT AND

ARE TO BE RAISED AS REQUIRED.

11. WORK TO ANY UTILITY CONDUIT OR PIPE SHALL BE PERFORMED BY SPECIFIC LICENSED

SUBCONTRACTORS SPECIALIZING IN HVAC, PLUMBING AND ELECTRICAL WORK. PERMITS AND

INSPECTIONS ARE REQUIRED. REROUTE AND / OR MODIFY UTILITY CONDUIT OR PIPE AS

REQUIRED TO BE INSTALLED AS DETAILED.

12. PROVIDE A "MERCURY" GAS LINE TEST (COORDINATE WITH OWNER AND ARCHITECT FOR

WITNESS OF TEST). REPAIR ANY FOUND LEAKS AND RETEST AS REQUIRED.

13. UNLESS INDICATED OTHERWISE ON THE CONSTRUCTION DOCUMENTS, REPLACE AND RAISE

ALL EXISTING EXPANSION JOINTS / AREA DIVIDERS / CURB MOUNTED EQUIPMENT / SKYLIGHTS

(AS APPLICABLE) A MIN. 10" ABOVE ROOF DECK.

14. ALL SOIL STACK FLASHING SHALL BE A MIN. 10" ABOVE FINISHED ROOF SURFACE. COUPLE

PVC PIPE ABOVE DECK AND COUPLE CAST IRON PIPE BELOW DECK.

15. ALL PIPING/ CONDUITS/ ETC. SHALL BE A MIN. 10" ABOVE ROOF SURFACE, NEW AND EXISTING.

PROVIDE PORTABLE PIPE HANGERS WITH PROTECTION PADS AS SPECIFIED. RAISE EXISTING

PIPING/ CONDUIT/ ETC. AS REQUIRED. MEP CONTRACTORS SHALL PROVIDE SUPPORTS FOR

UTILITY LINES.

16. PROVIDE SHEET METAL HOODED (WITH METAL FACE CLOSURE) CAPS, WOOD CURB, BOX

COVER AT ALL GAS AND WATER PIPE ROOF PENETRATIONS AS DETAILED. PROVIDE POSITIVE

SLOPE AWAY FROM FACE COVER.

17. PROVIDE WALKWAY PROTECTION PADS AS SPECIFIED AROUND ALL ROOF HATCHES, HVAC

ROOFTOP UNITS, DOORS THAT OPEN ONTO ROOF AND AT TOP AND BOTTOM OF ALL ROOF TOP

ACCESS LOCATIONS.

18. FALL PROTECTION DEVICES SHOWN ON THIS ROOF PLAN ARE FOR REFERENCE ONLY TO

IDENTIFY LOCATION OF FLASHING/WATERPROOFING DETAILS. REFERENCE STRUCTURAL

DRAWINGS FOR CONNECTION AND LAYOUT INFORMATION.

19. LIGHTING PROTECTION DEVICES SHOWN ON THIS ROOF PLAN ARE FOR REFERENCE ONLY TO

INDENTIFY LOCATIONS OF FLASHING/WATERPROOFING DETAILS.

20. INSTALL NEW SPLASH PAN AT ALL LOCATIONS WHERE ROOF DRAINAGE DISCHARGES ONTO

ROOF AREA. INSTALL NEW SPLASH BLOCKS WHERE ROOF DRAINAGE DISCHARGES ON GROUND.

21. ISOLATE ALL HEAT PIPES / FLUES AS DETAILED AND RECOMMENDED AND OUTLINED IN THE

NRCA MANUAL FOR HOT STACK FLASHING AND AS DETAILED.

22. ALL OUTSIDE AIR INTAKES SHALL BE COVERED TO ELIMINATE ODORS AND FUMES FROM

ENTERING INTO THE BUILDING DURING CONSTRUCTION WORK.

23. AFTER SUBSTANTIAL COMPLETION, THE GENERAL CONTRACTOR SHALL EXAMINE AND CLEAN

NEW DRAIN LINES AND NEW AND EXISTING (AS APPLICABLE) GUTTERS OF DEBRIS AND

BLOCKAGE, FLUSH WITH WATER TO ENSURE THAT DRAINS AND GUTTERS FLOW FREELY.

24. OWNER WILL VERIFY PROPER OPERATION OF ALL ROOF TOP EQUIPMENT BEFORE AND AFTER

THE PROJECT. CONTRACTOR SHALL BE RESPONSIBLE FOR IDENTIFYING ALL INOPERABLE

EQUIPMENT PRIOR TO RELEASE OF RETAINAGE.

25. PRIOR TO COMMENCEMENT OF WORK, COORDINATE WALK OF ENTIRE ROOF WITH ROOFING

MANUFACTURER'S TECHNICAL REPRESENTATIVE TO IDENTIFY AND LOCATE ALL AREAS OF HIGH

SLOPE OR OTHER CONDITIONS WHICH MIGHT REQUIRE SPECIAL PROCEDURES FOR SYSTEM

ATTACHMENT.

26. REFER TO MEP DRAWINGS FOR SIZE AND LOCATION OF DECK PENETRATIONS AND ROOF TOP

EQUIPMENT.

27. REFER TO GENERAL DETAILS FOR TYPICAL SPLASH PAN, ROOF DRAIN AND OVERFLOW DRAIN

DETAILS.

28. REPLACE ALL RUSTED AND / OR DETERIORATED EXISTING METAL VENT FLASHING AND FLUES.

29. GENERAL CONTRACTOR TO ENSURE ALL ROOFTOP PENETRATIONS (SOIL STACKS, VENTS,

ETC.) ARE INSTALLED MIN. 4'-0" FROM OTHER DECK PENETRATIONS, RISE WALLS, AND ROOF

EDGE. MECHANICAL EQUIPMENT TO BE LOCATED MIN. 10'-0" FROM PERIMETER EDGE AND NO

CLOSER THAN 4'-0" FROM RISE WALLS, OR ANY OTHER ROOF PENETRATION.

30. LOCATE PERIMETER DRAINS MAX. 6'-0" FROM EDGE TYPICAL UNLESS SHOWN OTHERWISE.

(GENERAL CONTRACTOR TO COORDINATE WITH ROOFING AND PLUMBING CONTRACTOR.)

31. THROUGH WALL BASE FLASHING MIN. HEIGHT 10" AND MAX. HEIGHT 20" FROM FINISH DECK. DO

NOT STEP THROUGH WALL FLASHING CLOSER THAN 5'-0" FROM CORNERS.

32. GENERAL CONTRACTOR SHALL COORDINATE LOCATION AND ORIENTATION OF ROOF HATCH

AND ACCESS LADDER.

33. GENERAL CONTRACTOR SHALL COORDINATE ALL TOP OF STEEL TO TOP OF BLOCKING AND

SUBSTRATE BOARD DIMENSIONS IN FIELD PRIOR TO ORDERING MATERIALS. NO ADDITIONAL

COMPENSATION WILL BE GRANTED FOR FAILURE TO COORDINATE THESE DIMENSIONS.

34. GENERAL CONTRACTOR SHALL VERIFY ROOF SLOPES WILL PROPERLY DRAIN AS SHOWN.

TAPERED INSULATION HATCHING SHOWN IS NOT INTENDED TO ILLUSTRATE THE ENTIRE LIMITS

OF TAPERED INSULATION. ROOF AREAS NOT SLOPED BY STRUCTURE SHALL BE SLOPED WITH

TAPERED INSULATION TO ACHIEVE PROPER DRAINAGE.

35. PROVIDE ONE WAY MOISTURE VENTS AT ALL LIGHTWEIGHT CONCRETE OR GYPSUM OVER

POUR AREAS AS RECOMMENDED BY THE ROOFING SYSTEM MANUFACTURER.

36. PAINT ALL EXISTING GAS PIPE TO REMAIN.

37. PROVIDE RETROFIT DRAIN KIT FOR EACH EXISTING ROOF DRAIN. RE: SPECS.

38. ALL ROOFING WORK SHALL OCCUR IN SUCH A MANNER AS NOT TO VOID ANY EXISTING ROOF

WARRANTIES. CONTRACTOR TO CONTACT ROOFING MANUFACTURER PRIOR TO COMMENCING

THE WORK. NO EXCEPTIONS.

39. FALL PROTECTION DEVICES SHOWN ON THIS ROOF PLAN ARE FOR REFERENCE ONLY TO

IDENTIFY LOCATIONS OF FLASHING/WATERPROOFING DETAILS. REFERENCE STRUCTURAL

DRAWINGS FOR CONNECTION AND LAYOUT INFORMATION.

40. LIGHTENING PROTECTION DEVICES SHOWN ON THIS ROOF PLAN ARE FOR REFERENCE ONLY

TO IDENTIFY LOCATIONS OF FLASHING/WATERPROOFING DETAILS

CURB MOUNTED VENT

(RE: & )

CURB MOUNTED

AC

ROOF HATCH

SKYLIGHTS

SCUPPER

GUTTER

DOWNSPOUT

RIDGE LINE

EXISTING AREA

TO REMAIN -NIC

METAL ROOF (N.I.C.)

A1 ROOF AREA

DESIGNATION

S

G

DS

R.T.U.

SL

NEW TAPERED

INSULATION / CRICKET

(RE: )

EXIST. ROOF DRAIN

W/ OVERFLOW

EXIST. ROOF DRAIN

VENT THROUGH ROOF

(RE: & )

CONDENSING UNITC.U.

OF

WALKPADS

(RE: )

6 / A-322

5 / A-322

14 / A-322 20 / A-322

8 / A-322 17 / A-322

N.I.C.

1 LAYER OF 2.2" POLYISO

INSULATION, ADHERED

(RE: SPECS)

1/2" RECOVERY BOARD,

ADHERED (RE: SPECS)

60 MIL FLEECEBACK

THERMOPLASTIC

MEMBRANE (RE: SPECS)

METAL DECK

(RE: STRUCTURAL)

2 LAYER OF 2.2" POLYISO

INSULATION, MECH. ATTACHED

(RE: SPECS)

METAL ROOF (N.I.C.)

CLOCK SYSTEM RECEIVER MOUNT TO CONDENSER

ROOF ACCESS DOOR - RE: (RE: SPECS)

WALL EXHAUST FAN DUCT AT CMU WALL

(E) MODIFIED BITUMEN ROOFING TO BE REPLACED IN-KIND WITH NEW

(RE: NOMENCLATURE 'A' & RE: SPECS)

13 / A-322

AREA APPROX.

SQ. FT.

EXISTING NOMENCLATURE PROPOSED

NOMENCLATURE

COMMENTS

A1 2,030 26/A-302MODIFIED BITUMEN ROOF

TOTAL 8,732

A2 1,354 26/A-302MODIFIED BITUMEN ROOF

A3 1,409 26/A-302MODIFIED BITUMEN ROOF

A4 3,939 26/A-302MODIFIED BITUMEN ROOF

N

R A

N C

H O

C U

C

AM

O N

G A

, C A

9-

7-

KEY PLAN

DATE PROJECT NUMBER

CLIENT

DRAWING HISTORY

w w w .p bk .c om

PLAN TRUE

FO

R

B

LU

E B

E A

M

LA

B E

LIN

G

/O C

R

Plot Stamp:

1"

0"

NORTH:

DRAWN BY:

CHECKED BY:

5/27/2026 2:45:25 PM

B

ID

S

ET

A-303

BUILDING 69 - ROOF

PLAN

05/27/26 260215

Mt. San Antonio College

M t.

Sa n

An to ni o

C ol le ge

N G ra nd

A ve

W al nu t, C

A

A -303

B U

ILD

IN

G 69 -R

O O

F PLA

N

Author

Checker

3/32" = 1'-0"1 BUILDING 69 - ROOF PLAN

N.T.S.

ROOF GENERAL NOTES

N.T.S.

LEGEND

N.T.S.26 ROOF NOMENCLATURE 'A'

N.T.S.27 ROOFING - KEYNOTES

A1

A2 A3

A4

N.T.S.19 ROOF AREA

36"

B

AB

A

B

B

B

A

A

B

DIRECTION OF SLOPE DICTATES WHETHER PICTURE FRAME LAPS ARE UNDERNEATH

OR ON TOP OF FIELD MEMBRANE SO AS NOT TO BUCK WATER.

6" MIN. END LAPS

3" MIN. SIDE LAPS

SLOPE

FOLLOW MANUFACTURER'S GUIDELINES FOR MAX. ROLL LENGTHS.

= CURB MOUNTED EQUIPMENT

PICTURE FRAME BOTH MOD. BIT. BASE PLY & FINISH PLY

A = PICTURE FRAME SHEETS

B = NATURAL PICTURE FRAME SHEETS

1/2" SPACE @ JOINT

10' MAX

EA. CAP

C O

N

TI

N U

O U

S C

LE

AT

F

AS

TE

N

ED

" O .C

-M

IN

. 1

" B

EL

O W

T O

P O

F W

AL

L

C

LA

D D

IN

G

SHEET METAL JOINT COVER

PLATE MIN. 6" WIDE SET IN 2

BEADS OF SEALANT- 1 EA. SIDE

OF JOINT.

PRE FINISHED METAL PARAPET CAP

HIGH DOMED, CAPPED,

GASKETED FASTENERS 18" O.C.

S.S. FASTENERS APPROX. 8" O.C.

FLASHING MEMBRANE

TERMINATION BAR AS REQ.

BY MANUFACTOR PER HGHT.

MOD. BIT. REINFORCING PLY

MOD. BIT. BASE PLY

MOD. BIT. FINISH PLY

PRIME WALL

TREATED WOOD NAILER

SECURE TO TOP OF WALL, 5/8"

DIA. X 10" THREADED ROD @

48" O.C MAX AND 6" FROM EACH

END W/ HILTI HIT HY- 270 EPOXY

ANCHOR PER ICC-ES ESR- 4143"

CONTINUOUS TAPERED

WOOD SHIM SUPPORT

AT CMU CONDITIONS REFER TO DETAIL: 18 / A-322

TAPERED EDGE STRIP

FLASHING MEMBRANE,

MIN 8" HEIGHT (RE: SPECS)

FASTENERS 8" O.C

22 GA. S.S. COVER W/

2" STANDING SEAMS

WATERPROOFING MEMEBRANE

TREATED 3/4"

EXT. PLYWOOD

TREATED 2X @

12" O.C. W/

CROSS BRACING

TREATED WD. CANT

TREATED 2X6 TYP.

ROOF DECK

ROOF TOP EQUIPMENT

(E) BEAMS ON

NEW MOD. BIT.

PADS

DOMED GASKETED

FASTENERS 12" O.C.

REMOVABLE S.S

COUNTER FLASHING W/

HEM & KICK OUT

NOTE: PROVIDE "X" BREAK IN CAP TO

CREATE POSITIVE SLOPE - WELD ALL JOINTS

- DO NOT FASTEN THRU TOP OF CAP

NOTE: INSTALL NEW PLATFORM

OVER FIELD OF ROOF SYSTEM

F.V. CURB SPANS AT LEAST 2

STRUCTURAL MEMBERS

MOD. BIT. REINFORCING PLY

MOD. BIT. FINISH PLY

MOD. BIT. BASE PLY

BASE SHEET

ROOF SCUTTLE

PREFABRICATED

INSULATED CURB

STD. CURB FLASHING

DETAIL SIM.

WALKPADS ALL AROUND

RE: WALKPADS

1'

0"

3' - 0"

2' - 6

2 / A-322

5 / A-322

6" MIN

PLAN

ISOMETERIC VIEW

REINFORCING FABRIC PIPE WRAP

12"X12" REINFORCING

FABRIC OVER PIPE WRAP

FOUNDATION COAT,

FABRIC,

FOUNDATION COAT

COMPONENTS

PLACE ADDITIONAL

LAYERS OF REINFORCING

FABRIC AT PENETRATION

BASE

VENT PIPE

ROOF DECK

FINISH COAT COMPONENT

STORM

COLLAR, IF

REQUIRED

STANDARD

PREMIUM COAT

ROOF SYSTEM

PIPE, THROUGH ROOF DECK

LAYER OF 12"X12"

REINFORCING FABRIC OVER

PIPE WRAP

REINFORCING FABRIC PIPE WRAP

NOTES:

1. THIS DETAIL IS A TYPICAL PENETRATRION DETAIL APPLICABLE FOR ALL COLD PIPE

PENETRATIONS. FOR HOT PIPE PENETRATIONS CONTACT THE MANUFACTURER FOR

REQUIREMENTS.

2. FOR PIPE PENETRATIONS THAT EXCEED 18" ABOVE THE ROOF SURFACE A STORM

COLLAR SHALL BE USED WITH A DRAW BAND AND SEALANT. THE ROOF COATING

SHALL EXTEND 8" MIN. UP PENETRATION SURFACE AS INDICATED.

ROOF SYSTEM

FOUNDATION COAT, FABRIC, AND

FOUNDATION COAT COMPONENTS

TAKE 12" WIDE FOUNDATION COAT, FABRIC,

AND FOUNDATION COAT COMPONENTS UP

CANT AND TERMINATE VERTICALLY ON PARAPET

PARAPET WALL

FINISH COAT COMPONENT OVER ENTIRE

ROOF (2 COATS). FINISH IN SPECIFIED COLOR.

TAKE ENTIRE SYSTEM COMPLETELY OVER

TOP OF PARAPET

OPTIONAL METAL COPING ASSEMBLY

NOTES:

1. ALL FLASHING SHALL BE DESIGNED FOR THE APPLICABLE CONDITIONS. METAL

THICKNESS, FASTENERS, AND LAPPING SHALL BE AS SPECIFIED BY THE ROOF

DESGINER.

2. REFER TO THE SPECIFICATIONS FOR SPECIFIC EXECUTION REQUIREMENTS.

3. PREMIUM COAT SYSTEM - FOUNDATIONS COAT, FABRIC, FOUNDATION COAT, AND

FINISH COAT COMPONENTS.

4. FOUNDATION COAT - COMBINED COVERAGE (2 COATS) AT MINIMUM RATE OF

40SF/GALLON.

5. FINISH COAT - COMBINED COVERAGE (2 COATS) AT MINIMUM RATE OF 70 SF/GALLON.

6. PRIMING - REFER TO MANUFACTURER SPECIFICATIONS FOR DECK PRIMING

REQUIREMENTS.

1" MIN.

1/2" MIN.

10" NOMINAL

CURB HEIGHT

HIGH-DOMED , CAPPED, GASKETED

STAINLESS STEEL FASTENERS @ 18"

O.C. (MIN. 2 FASTENERS PER SIDE)

REMOVABLE PRE-FINISHED SHEET

METAL COUNTER FLASHING

S.S. FASTENERS @ 8" O.C.

FINISH COAT COMPONENT

FOUNDATION COAT, FABRIC, AND

FOUNDATION COAT COMPONENTS

CONTINUOUS SEALING MATERIAL AT TOP OF CURB

MECHANICAL UNIT, HOOD, ETC. BASE EXTENDS 1/2"

MIN BEYOND EDGE OF CURB

STAINLESS STEEL FASTENERS @ 8" O.C.

COATING UP CURB ASSEMBLY

12" x 12" REINFORCING FABRIC, CUT TO FIT INTO CORNER.

TAKE CUT UP TO TOP OF CANT DIMENSION

ROOF

PARAPET AT

CORNER

TOP OF FABRIC

START OF CUT

REINFORCING FABRIC,

CUT TO FIT TIGHT AT CANT

AND TO OVERLAP ON

ROOF.

NOTES:

1. PREMIUM COAT SYSTEM- FOUNDATION COAT, FABRIC, FOUNDATION COAT,

AND FINISH COAT COMPONENTS.

2. FOUNDATION COAT- COMBINED COVERAGE (2 COATS) AT MINIMUM RATE OF

40SF/GALLON.

3. FINISH COAT - COMBINED COVERAGE (2 COATS) AT MINIMUM RATE OF 70

SF/GALLON.

4. PRIMING - REFER TO MANUFACTURERE SPECIFICATIONS FOR DECK PRIMING

REQUIREMENTS.

ISOMETRIC VIEW

6" M

IN

1" MIN. GAP

1" MIN. GAP

EQUIPMENT CURB AS

DETAILED FOR

SPECIFIED ROOF

SYSTEM

30" WIDE MIN. SINGLE-PLY

HEAT-WELD WALK PADS

AROUND

PERIMETER OF ROOF

TOP EQUIPMENT, TYP.

AT ALL

CONTINUOUS

WALK WAY

PATH

ROOF TOP

EQUIPMENT

RE: MEP

VERTICAL FRAMING

(SEE STRUCTURAL)

ROOFING MATERIAL 1/2" COVER BOARD

TAPERED RIGID

INSULATION OVER ROOF

DECK

(E) BASE AND

FLOOR AS

SCHEDULED

(N) MOD-BIT FLASHING

SYSTEM (RE: SIM. BASE

FLASHING DETAIL

(N) COUNTER

FLASHING

ANCHORED 8" O.C. W/

WIND CLIPS @ 3" O.C.

(E) HM STEEL FRAME

(N) FULLY ADHERED

WATERPROOFING

MEMBRANE(E) ACCESS DOOR

WALL BEYOND - THRU- WALL

FLASHING 2'-0" ON EACH SIDE

OF DOOR

(E) ROOF DECK

RE: STRUCTURAL

INTERIOR EXTERIOR

(E) DOOR FRAME

(E)GYP. BD O/

VAPOR BARRIER

8" M

IN

/1 6" 2 / A-322

SELF-ADHERING TORCH GRADE BASE

FLASHING PLY, 6" MIN. (152mm) ON FIELD

TORCH GRADE

COVER BOARD

CAP FLASHING PLY, 9" MIN. (229mm)

ON FIELD

TORCH APPLIED MODIFIED MEMBRANE

MODIFIED BASE SHEET - SELF

ADHERING TORCH-GRADE TO BE USED

TO CONCEAL ALL WOOD AND

FLASHING COMPONENTS AND JOINTS.

TORCH APPLIED BASE SHEET TO BE

USED IN FIELD OF ROOF

TORCH GRADE

PROTECTION BOARD

METAL EXHAUST FAN COVER

FLASHING FASTENED 8" O.C. (203mm)

METAL CAP SECURED 24" O.C. (610mm)

W/ FASTENERS W/ NEOPRENE WASHERS

8" M

IN

(E) ROOF DECK

NOTE:

1. PRIME ALL WOOD COMPONENTS WITH

INTUMESCENT PRIMER.

2. REF. SPECIFICATION FOR SURFACING

MEMBRANE TYPE, & INSULATION/COVER

BOARD TYPE & ATTACHMENT METHOD.

TORCH GRADE

CANT STRIP

CLAMPING RING

STAINER

SOFT METAL FLASHING (30" MIN.) SET IN

MASTIC, WRAPPED DOWN 2" MIN., PRIME TOP

SURFACE

SELF-ADHERING TORCH GRADE BASE

FLASHING PLY, 6" MIN. (152mm) ON FIELD

TORCH GRADE

COVER BOARD

CAP FLASHING PLY, 9" MIN. (229mm) ON FIELD

DECK CLAMP

TORCH APPLIED MODIFIED MEMBRANE

MODIFIED BASE SHEET - SELF ADHERING

TORCH-GRADE TO BE USED TO CONCEAL

ALL WOOD AND FLASHING COMPONENTS

AND JOINTS. TORCH APPLIED BASE SHEET

TO BE USED IN FIELD OF ROOF

NOTE: NON-PENETRATING PIPE SUPPORTS MAX 8'-0" O.C. INCLUDING (BETWEEN SEISMIC

SUPPORTS) AND 2'-0" FROM CHANGE OF DIRECTION OR ELEVATION.

GAS PIPE SUPPORTS LINES

LESS THAN 3" O.D.

ROLLER HANGER W/HOLD

DOWN CLIPS

SUPPORT BASE MIN 10"x16"x3"

TACK SUPPORTS TO PAD

WITH APPROVED MASTIC OR

ADHESIVE

STRUCT W/HOLD

DOWN CLIPS

ROOF MANUFACTURE

APPROVED PROTECTIVE

TRAFFIC PAD

ELECTRICAL

CONDUIT/CONDENSATE

LINES LESS THAN 3" O.D.

NOTE:

REFERENCE SPECIFICATION FOR SURFACING, MEMBRANE ADHESIVE TYPE, AND

INSULATION/COVER BOARD TYPE AND ATTACHMENT METHOD.

PIPE PENETRATION

DRAWBAND OR WELD

UMBRELLA TO STACK

WATERTIGHT SHEET

METAL RAIN COLLAR

OVERLAPPING SOFT

METAL JACK

4" MIN.

PREPARE AND

CLEAN PIPE PRIOR

TO APPLYING

FLASHING

SEALANT, REFERENCE

SPECIFICATION

SEAL GAP AROUND PIPES

W/ FOAM

SPLIT SOFT METAL

ROOF JACK

SEALANT, REFERENCE

SPECIFICATION

CAP FLASHING PLY 9"

MIN. ON FIELD

BASE FLASHING PLY 6"

MIN. ON FIELD

MODIFIED MEMBRANE

BASE PLY

NAILED BASE SHEET

ROSIN PAPER

WOOD DECK

SET SOFT METAL FLANGE IN

MASTIC, PRIME FLANGE

BEFORE STRIPPING

MECHANICAL EXHAUST FAN UNIT

FAN CURB AT MIN. OF 8" ABOVE ROOF LINE.

FINISH COAT COMPONENT (2 COATS) OVER

ENTIRE ROOF

36" COATING SYSTEM

PREMIUM COAT SYSTEM: FOUNDATION

COAT, FABRIC, FOUNDATION COAT, AND

TWO COATS OF FINISH COAT.

12" FOUNDATION COAT, FABRIC, AND

FOUNDATION COAT COMPONENTS.

ROOF DECK

PROVIDE COATING SYSTEM

ALL AROUND FAN UNIT EXTENDING 36"

OUT FROM FACE OF CURB ON ALL

SIDES.

EXHAUST FAN UNIT MOUNTED ON ROOF.

NOTES:

1. THIS DETAIL IS A TYPICAL FLASHING DETAIL AT EXHAUST FANS FOR COOKING.

"BARRIERGUARD" SYSTEM IS NOT USED FOR STANDARD EXHAUST FANS.

2. PREPARE THE ROOF SURFACE AS PER MANUFACTURER'S REQUIREMENTS PRIOR

TO APPLICATION OF ROOF COATING.

3. REFER TO THE SPECIFICATIONS FOR SPECIFIC EXECUTION REQUIREMENTS.

4. PREMIUM COAT SYSTEM - FOUNDATION COAT, FABRIC, FOUNDATION COAT, AND

FINISH COAT COMPONENTS.

5. FOUNDATION COAT - COMBINED COVERAGE (2 COATS) AT MINIMUM RATE OF

40 SF/GALLON.

6. FINISH COAT - COMBINED COVERAGE (2 COATS) AT MINIMUM RATE OF 70 SF/GALLON.

7. PRIMING - REFER TO MANUFACTURER SPECIFICATIONS FOR DECK PRIMING

REQUIREMENTS.

36" TYP.

36" COATING SYSTEM

SOLDER JOINTS: COMPLETELY

SEALED AT WINDOW JAM

STAINLESS STEEL REGLET

FASTENERS APPROX. 24" O.C.

2" WIDE WIND CLIPS APPROX. 3' O.C.

TERMINATION BAR WITH FASTENERS

APPROX. 8" O.C.

REMOVABLE COUNTER FLASHING,

FASTENERS APPROX. 24" O.C.

BASE SHEET FASTENERS

FLASHING MEMBRANE (RE:

SPECS)

REINFORCING/ STRIPPING PLY

MOD. BIT. FINISH PLY (RE: SPECS)

MOD. BIT. BASE PLY (RE: SPECS)

BASE SHEET (RE: SPECS)

FIBER CANT

10' MAX. LENGTH

EA. PIECE OF

PERIMETER

FLASHING

6" MIN.

1/2" GAP

1" M

IN

BE

LO

W T

O P

O F

W

AL

L

4" MIN.

4" MIN.

SHEET MTL. GRAVEL STOP SET IN

ROOF CEMENT; BUFF SAND THEN

PRIME FLANGE BEFORE STRIPPING

CONTINUOUS BEAD OF

SEALANT ALONG PERIMETER

SHEET MTL. JOINT COVER PLATE SET IN

BED OF MASTIC PRIME FLANGE BEFORE

STRIPPING

S.S. FASTENERS

STAGGERED 3" O.C. REFER TO

ES-1 FASTENER SIZE REQUIREMENTS

MOD. BIT. FINISH PLY

MOD. BIT. BASE PLY

MOD. BIT. STRIPPING PLY

BASE SHEET

ROOF DECK

EXTEND BASE PLY MOD. BIT. MEMBRANE TO BELOW WALL

CONTINUOUS CLEAT FASTENED APPROX. 6" O.C.

1"

1" 3"

8" M

IN

BASE SHEET

CANT

S.S. RECEIVER/REMOVABLE

COUNTER FLASHING W/ WIND CLIPS

@ 3' O.C.

SECURE AND SEAL METAL RECEIVER

TO SHEATHING BOARD

PLASTER

FLEXIBLE

VAPOR

RETARDER W/

COMPRESSIBLE

INSULATION

DAMPROOFING

3/4"

PLYWOOD

SECURE TO

SHEATHING

BOARD

ROOF ASSEMBLY

(RE: NOMENCLATURE)

REMOVABLE COUNTER FLASHING

ANCHORED 8" O.C. W/ WIND CLIPS @ 3'

O.C.

METAL STUD

BACKUP

WALL

FLASHING MEMBRANE

MOD. BIT. REINFORCING PLY

MOD. BIT. FINISH PLY

MOD. BIT. BASE PLY

EXTERIOR

SHEATHING

R A

N C

H O

C U

C

AM

O N

G A

, C A

9-

7-

DATE PROJECT NUMBER

CLIENT

DRAWING HISTORY

w w w .p bk .c om

FO

R

B

LU

E B

E A

M

LA

B E

LIN

G

/O C

R

Plot Stamp:

1"

0"

DRAWN BY:

CHECKED BY:

5/27/2026 3:00:31 PM

B

ID

S

ET

A-322

ROOF DETAILS

05/27/26 260215

Mt. San Antonio College

M t.

Sa n

An to ni o

C ol le ge

N G ra nd

A ve

W al nu t, C

A

A -322

R O

O F D

ETA

ILS

Author

Checker

N.T.S.1 PICTURE FRAME

N.T.S.2 PARAPET BASE & CAP

N.T.S.3 CURB PLATFORM

N.T.S.4 ROOF HATCH

N.T.S.8 PLUMBING VENT

N.T.S.10 PARAPET BASE AND CAP

N.T.S.11 EQUIPMENT CURB

N.T.S.12 CORNER FLASHING

12" = 1'-0"5 WALKPADS

N.T.S.6 CRICKET

N.T.S.13 ROOF ACCESS DOOR @ SILL

N.T.S.14 EXHAUST FAN CURB

N.T.S.15 ROOF DRAIN

N.T.S.16 PIPE SUPPORTS V2

N.T.S.17 PIPE/TUBE PENETRATION

N.T.S.20 EXHAUST FAN

N.T.S.18 BASE FLASHING @ CMU

N.T.S.21 PERIMTER EDGE

N.T.S.22 EJ BASE FLASHING @ STUCCO WALL

File details come from the government source that posted it. Updated .