About this file
The document is a set of architectural and electrical design drawings for the Classrooms Ceiling and Lighting Replacement project at the Elwyn G. Campbell Elementary School, located at 145 Essex Street in New Bedford, Massachusetts. The project involves comprehensive ceiling and lighting upgrades across multiple rooms, including classrooms, corridors, offices, and special purpose spaces. The drawings, dated January 27, 2025, are prepared by CSS Architects Inc. and IMEG Architectural Engineers Inc., and detail the removal of existing acoustic ceiling systems and light fixtures, and the installation of new suspended ceiling grids, acoustical tiles, and LED lighting fixtures throughout the school building.
The project is part of the MSBA Accelerated Repair Program with an estimated budget of $500,000 and a targeted substantial completion date of August 28, 2025. The design documents specify detailed requirements for ceiling heights, lighting placement, and electrical work, with multiple fixture types indicated in the lighting fixture schedule. The project requires a DCAMM Prime General Contractor certified in Electrical and DCAMM Filed Sub-Bidders certified in Acoustical Tile Ceilings. The drawings provide comprehensive floor plans showing the exact locations of new ceiling systems and lighting fixtures, indicating a methodical approach to modernizing the school's interior infrastructure.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T1.0 - TITLE SHEET
A1.1 - REFLECTED CEILING PLAN AND DETAILS
E0.0 - ELECTRICAL LEGEND, NOTES, DETAILS & ABBREVIATIONS
ED1.1 - ELECTRICAL DEMOLITION LIGHTING FLOOR PLAN
E1.1 - ELECTRICAL NEW LIGHTING FLOOR PLANCSS Architects Inc.
107 Audubon Road Bldg. 2, Suite 300 Wakefield, MA 01880 T: 781-245-8400 F: 781-245-9372 www.cssarchitects.com
Architect
CL
AS
SR
OO
MS
C
EI
LIN
G
AN
D
LIG
HT
IN
G
RE
PL
AC
EM
EN
T
AT
T
HE
E
LW
YN
G
. C
AM
PB
EL
L
EL
EM
EN
TA
RY
S
CH
OO
L
ELWYN G. CAMPBELL
ELEMENTARY SCHOOL
145 ESSEX ST. NEW BEDFORD
CLASSROOMS CEILING AND LIGHTING REPLACEMENT AT THE
ELWYN G. CAMPBELL ELEMENTARY SCHOOL
145 ESSEX STREET
NEW BEDFORD, MA 02745
Electrical Engineer
IMEG / Architectural Engineers Inc 31 Milk Street Boston, MA 02196 T: 617-542-0810 F: 617.542.8451 www.imegcorp.com
DRAWING LIST
AERIAL VIEW
LOCUS MAP
AutoCAD SHX Text January 27, 2025
AutoCAD SHX Text T1.0
LOBBY
GYM STORAGE
151PLAYGROUND
EQUIPMENT
CORRIDOR
ART & MUSIC
ROOM 16
GRADE 4
ROOM 20
GRADE 5
ROOM 15
GRADE 5
ROOM 17
SPED / TLS
ROOM 19
STORAGE
GYMNASIUM
CUST.
115A
JANITOR'S
OFFICE
CUST.
PLATFORM
105A
MULTI-PURPOSE
ROOM
BOILER ROOM
CUST.
106B
STORAGE
STORAGE
CUST.
STORAGE
STORAGE
129A
VEST.
VEST.
DISHWASHING
106A
KITCHEN
STORAGE
GIRLS TOILET
SPED
FACILITATOR
TEACHERS
LOUNGE
NURSE
TOILET
101A
OFFICE
ADMIN.
PRINCIPAL
TESTING
ROOM
OFFICE
OFFICE
ENTRY VEST.
100A
VEST.
128C
KINDERGARTEN
ROOM 1
TOILET
128B
KINDERGARTEN
ROOM 2
TOILET
130A
PRE-K
ROOM 3
TOILET
131A
VEST.
133B
PRE-K
ROOM 4
TOILET
133A
PRE-K
ROOM 5
VEST.
TOILET
134A
PRE-K
ROOM 6
VEST.
136B
TOILET
136A
PRE-K
ROOM 7
TOILET
137A
TOILET
139A
VEST.
139B
VEST.
VEST.
113A
CORRIDOR
GRADE 2
ROOM 10
GRADE 2
ROOM 9
MEN
STORAGE
STORAGE
OFFICE
105B
SAC /
TUTORING
GIRLS
TOILET
BOYS
TOILET
GRADE 3
ROOM 12
GRADE 1
ROOM 11
VEST.
117A
VEST.
120A
GRADE 3
ROOM 14
GRADE 1
ROOM 13
CORRIDOR
VEST.
LOBBY
BOYS TOILET
CORR.
CORRIDOR
MANAGER
OFFICE
107CORRIDOR
STORAGE
WOMEN
CORRIDOR
CORRIDOR
TOILET
102A
PRE-K
ROOM 8
SENSORY
ROOM
EXISTING FOLDABLE PARTITION
CEILING TRACK & TRIM
DROP CEILING SYSTEM
@ CONCRETE SOFFIT
FSB ACT CONTRACTOR TO
REMOVE AND DISPOSE EXIST.
ACOUSTIC CEILING STSTEM
AND PROVIDE NEW ACOUSTIC
CEILING SYSTEM .
GC TO REMOVE & DISPOSE EXISTING
LIGHT FIXTURES AND PROVIDE NEW
LIGHT FIXTURES, SEE ELECT. DWG'S.
A1.1
A1.1
GRADE 4
ROOM 18
FSB ACT CONTRACTOR TOREMOVE &
DISPOSE EXISTING CEILING GRID SYSTEM &
PROVIDE NEW ACOUSTICAL CEILING SYSTEM
LEGEND
2'x2' LED LIGHT FIXTURE, SEE ELECT. DWG'S.
REMOVE EXISTING ACOUSTIC CEILING SYSTEM AND
PROVIDE NEW 2x2 ACOUSTIC CEILING TILE SYSTEM.
RECESSED DOWNLIGHT, CENTER IN CEILING TILE.
SEE ELECT. DWG'S.
CEILING HEIGHT NOTE
ROOMS W/ EXISTING SUSPENDED CEILING SYSTEMS:
MATCH EXISTING SUSPENDED HEIGHT
1'x1' SURFACE MOUNTED LIGHT FIXTURE, CENTERED
IN ROOM. SEE ELECT. DWG'S.
EXISTING 1x1 CEILING TILES TO REMAIN. FSB ACT
CONTRACTOR TO PROVIDE NEW ACOUSTIC CEILING
SYSTEM 8"+ BELOW
FSB ACT CONTRACTOR TO REMOVE & DISPOSE
EXISTING 2x4 ACOUSTIC CEILING SYSTEM AND
PROVIDE NEW ACOUSTIC CEILING SYSTEM
GC TO REMOVE & DISPOSE EXISTING
LIGHT FIXTURES AND PROVIDE NEW
LIGHT FIXTURES, SEE ELECT. DWG'S.
GC TO REMOVE & DISPOSE EXISTING
LIGHT FIXTURES AND PROVIDE NEW
LIGHT FIXTURES, SEE ELECT. DWG'S.
GC TO REMOVE & DISPOSE EXISTING
LIGHT FIXTURES AND PROVIDE NEW
LIGHT FIXTURES, SEE ELECT. DWG'S.
GC TO REMOVE & DISPOSE EXISTING
LIGHT FIXTURES AND PROVIDE NEW
LIGHT FIXTURES, SEE ELECT. DWG'S.
ELECTRICAL GC TO REMOVE & DISPOSE EXISTING LIGHT
FIXTURES AND PROVIDE NEW LIGHT FIXTURES, IN NEW
ACOUSTICAL CEILING SYSTEM, SEE ELECT. DWG'S. FSB ACT
CONTRACTOR TO REMOVE & DISPOSE EXISTING 2x4
ACOUSTIC CEILING SYSTEM AND PROVIDE NEW ACOUSTIC
CEILING SYSTEM ELECTRICAL GC TO REMOVE & DISPOSE EXISTING
LIGHT FIXTURES AND PROVIDE NEW LIGHT FIXTURES,
IN NEW ACOUSTICAL CEILING SYSTEM, SEE ELECT.
DWG'S.
EXISTING 1X1 CEILING TILES TO REMAIN FSB ACT
CONTRACTOR TO PROVIDE NEW ACOUSTIC
CEILING SYSTEM 8" + BELOW EXISTING.
GC TO REMOVE & DISPOSE EXISTING
LIGHT FIXTURES AND PROVIDE NEW LIGHT
FIXTURES, IN EXIST. ACOUSTICAL CEILING
SYSTEM, SEE ELECT. DWG'S.
ROOMS WITHOUT SUSPENDED CEILING SYSTEMS 113,
114, 117, 118, 119 AND 120:
NEW ACOUSTICAL CEILING TO BE SET 8" ± BELOW
EXISTING TO WORK AROUND EXISTING CONDUCT,
SPEAKERS AND DEVICES
GC TO REMOVE & DISPOSE EXISTING LIGHT
FIXTURES AND PROVIDE NEW LIGHT FIXTURES,
IN NEW ACOUSTICAL CEILING SYSTEM, SEE
ELECT. DWG'S.
EXISTING CEILING, PAINTED
A1.1
FSB ACT CONTRACTOR TO REMOVE & DISPOSE
EXISTING 2x4 ACOUSTIC CEILING SYSTEM AND
PROVIDE NEW ACOUSTIC CEILING SYSTEM FSB ACT CONTRACTOR TO REMOVE & DISPOSE
EXISTING 2x4 ACOUSTIC CEILING SYSTEM AND
PROVIDE NEW ACOUSTIC CEILING SYSTEM
ELECTRICAL GC TO REMOVE & DISPOSE EXISTING
LIGHT FIXTURES AND PROVIDE NEW LIGHT FIXTURES,
IN NEW ACOUSTICAL CEILING SYSTEM, SEE ELECT.
DWG'S.
EXISTING 1x1 CEILING TILES TO REMAIN. FSB ACT
CONTRACTOR TO PROVIDE NEW ACOUSTIC CEILING
SYSTEM 8"+ BELOW EXISTING
EXIST. CONCRETE ROOF DECK
NEW 11
2" HAT
CHANNELS AT 16" O.C.
NEW 58" PLASTER BASE WITH
VENEER PLASTER, PTD.
ACOUSTICAL CEILING @ FOLDING PARTITION 2 TYPICAL PLASTER CEILING 1
SUSPENDED
ACOUSTICAL
CEILING SYSTEM
EXISTING FOLDING
PARTITION SUPPORT
SYSTEM
NEW ACOUSTICAL
CEILING WALL ANGLE
EXISTING FOLDING
PARTITION TRIM
EXISTING FOLDING
PARTITION
NEW CONTINUOUS SEALANT
SCALE: 3" = 1'-0" SCALE: 3" = 1'-0"
TAPE-IN J-BEAD
Scale:
Date:
Drawn:
Checked:
Project No:
KMS
JAN. 27, 2025
CLASSROOMS CEILING
AND LIGHTING
REPLACEMENT AT THE
ELWYN G. CAMPBELL
ELEMENTARY SCHOOL
MSBA ACCELERATED
REPAIR PROGRAM
145 ESSEX STREET
NEW BEDFORD, MA 02745
1 0 7 A u d u b o n R o a d Building 2, Suite 300 Wakef ield, MA 01880 css@cssarchitects.com
CSS ARCHITECTS INC.
Title:
Revisions
No. Date Description By
32"=1'-0" UON
A1.1
REFLECTED CEILING
PLAN & DETAILS
AV/DL
DWG'S. DRAWINGS
ELECT. ELECTRICAL
EXIST. EXISTING
G.C. GENERAL CONTRACTOR
MAX. MAXIMUM
MIN. MINIMUM
N.T.B. NOT TO SCALE
PTD. PAINTED
REQ'D. REQUIRED
U.O.N. UNLESS OTHERWISE NOTED
TYP. TYPICAL
V.I.F. VERIFY IN FIELD
1. ALL ITEMS AND MATERIALS ARE TO BE NEW UNLESS
INDICATED AS EXISTING OR EXISTING TO BE REINSTALLED.
2. ALL QUANTITIES, CONDITIONS AND DIMENSIONS SHOWN ON
DRAWINGS MUST BE VERIFIED IN FIELD PRIOR TO
SUBMITTING SHOP DRAWINGS AND COMMENCING WORK.
4. ELECTRICAL G.C. TO MAKE SAFE ALL RELATED ELECTRICAL
WORK PRIOR TO DEMOLITION.
5. G.C. RESPONSIBLE FOR DAMAGE THAT OCCURS TO ALL
BUILDING MATERIALS AND ELEMENTS THAT ARE
SCHEDULED TO REMAIN.
6. CLEAN AND REPAIR DAMAGE CAUSED BY INSTALLATION OR
USE OF TEMPORARY FACILITIES. RESTORE EXISTING
FACILITIES AND SITE USED DURING CONSTRUCTION TO ITS
ORIGINAL CONDITION.
ABBREVIATIONSGENERAL NOTES
Scale:
Date:
Drawn:
Checked:
Project No:
JAN 27,2025
Title:
Revisions
No. Date Description By
X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Scale:
Date:
Drawn:
Checked:
Project No:
JAN 27,2025
Title:
Revisions
No. Date Description By
ELECTRICAL NEW LIGHTING PLAN
SCALE: 3/32" = 1'-0"
Scale:
Date:
Drawn:
Checked:
Project No:
JAN 27,2025
Title:
Revisions
No. Date Description By
ELECTRICAL NEW LIGHTING PLAN
SCALE: 3/32" = 1'-0"
| Campbell ES-Lighting_Electrical Drawings.pdf |
| E000 - Electrical Legend, Notes, Details, & Abbreviations |
| E000 |
| ED200 - Electrical Demolition Lighting Plan |
| ED-200 |
| E200 - Electrical New Lighting Plan |
| E200 |
File details come from the government source that posted it. Updated .