206A_Washington_Ave_250821.pdf
PDF 3 MB Posted
- Solicitation number
- 26-008
- Issued by
- Charles County, Maryland
About this file
This is a Pre-Demolition Hazardous Materials Survey Report prepared by International Academy, Inc. for 206A Washington Avenue in La Plata, Maryland, conducted on behalf of Waco, Inc. The survey was completed in conjunction with Charles County's demolition project for four structures in the Town of La Plata. The inspection and sampling activities occurred on July 18 and July 23, 2024, with the report dated August 21, 2024. The assessment identified and tested for asbestos-containing materials (ACMs), lead-based paint (LBP), above-ground heating oil tanks, polychlorinated biphenyl (PCB) light ballasts, mercury-containing light tubes, and battery-operated lighting fixtures. A total of 43 bulk samples were collected from suspect asbestos-containing materials and submitted to Environmental Hazard Services LLC for analysis using EPA Method 600/R-93/116. Lead-based paint testing was conducted using portable X-Ray Fluorescence (XRF) analysis on accessible interior and exterior painted surfaces following HUD Guidelines for single-family housing protocols.
The survey results indicate no asbestos was detected in any of the 43 samples analyzed, with all materials tested reporting as "NAD" (No Asbestos Detected). Lead-based paint testing revealed no paint samples containing lead equal to or greater than 0.7 mg/cm², meaning all detected paint contains less than the regulatory threshold and is classified as "Negative." However, the inspection identified eight four-foot mercury-containing fluorescent light tubes in the basement overhead lighting fixtures that require specialized disposal under EPA RCRA regulations, and two unlabeled light ballasts in basement fixtures that must be assumed to contain PCBs and disposed of in accordance with 40 CFR Part 761. No above-ground heating oil tanks or emergency lighting/exit sign batteries were observed at the property. The report concludes that while no asbestos or lead-based paint abatement is required, the identified mercury-containing bulbs and PCB ballasts must be properly removed and disposed of by permitted facilities prior to demolition activities.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N
° 3 7'
1"
W
7.
N84° 41' 50"E
645.13'
S0 3°
1'
7"
E
5.
S88° 01' 58"W
646.21'
S0 3°
1'
7"
E
9.
S0 3°
1'
7"
E
4.
S83° 53' 44"W 40.00'
N04° 00' 14"W 9.00'
N88° 05' 39"W 180.16'
N
° 0 8'
1"
W
5.
' S89° 08' 11"W
220.09'
N
° 0 8'
1"
W
0.
S89° 01' 58"W 408.53'
S0 3°
8'
1"
E
4.
N
° 2 8'
2"
W
.0 0'
N02° 28' 02"W 15.04'
S89° 01' 58"W175.00'
S0 2°
0'
2"
E
.0 0'
UK
BaC
BaB
BaB
BaB BuB
BaB
BuB
190190
190190
160159
187 18
187 188
0 20 40 80 120
SCALE� 1" 40'
W
ASH
IN
G
TO
N
AVE
VAR
IABLE W
ID
TH
R
O W
TALBOT ST
EX. N
O R
TH
M
APLE AVE
LAN
D
S N /F N
EW
YO
R K C
EN
TR
AL R
AILR
O
AD
COURTHOUSE PARKING
COURTHOUSE PARKING
MAREDITH BUILDING
3 STORY OFFICE BUILDING
TM 0113 G 0001 P 0084
N/F 200 WASHINGTON AVE LLC
OFFICE BUILDING
200 WASHINGTON AVE
TM 0113 G 0001 P 0082
N/F RALPH & PAULA
WINKLER
214 WASHINGTON AVE
TM 0113 G 0001 P 0089
N/F GEORGE & MARY
ANN SCOTT
214A WASHINGTON AVE
TM 0113 G 0001 P 0089
N/F LYNNE & FELICA
TAGGART
214B WASHINGTON AVE
TM 0113 G 0001 P 0089
N/F RICHARD & MARGUE BALDUS
217 WASHINGTON AVE
TM 0112 G 0006 P 0099
N/F SOUTHERN
MARYLAND OIL INC
TM 0113 G 0001 P 0066
N/F SOUTHERN MARYLAND OIL INC
109 NORTH MAPLE AVE
TM 0113 G 0001 P 0067
LAND N/F COUNTY
COMMISSIONERS OF
CHARLES COUNTY
TM 0112 G 0006 P 0046
LAND N/F COUNTY
COMMISSIONERS OF
CHARLES COUNTY
TM 0113 G 0001 P 0089
LAND N/F COUNTY
COMMISSIONERS OF
CHARLES COUNTY
TM 0113 G 0001 P 0090
LAND N/F COUNTY
COMMISSIONERS OF
CHARLES COUNTY
COURTHOUSE
TM 0113 G 0001 P 0091
38" MAPLE TREE
20" MAGNOLIA TREE
EX. PRIVATE DRIVE
EX. BMP OUTFALL ELEVATION 182.49EX. BMP OUTFALL ELEVATION 182.49
EX. 2 STORY WINKLER HOUSE
E
0.
N 315600.00 E
0.
N 315600.00
E
0.
N 315000.00
N/F BATTLE CREEK
CONSTRUCTION LLC
202 WASHINGTON AVE
TM 0113 G 0001 P 0083
N/F LA PLATA HOLDINGS, LLC
STORAGE WAREHOUSE
205 KENT AVE
TM 0113 G 0002 P 0058
N/F REYNOLDS PROPERTIES LLC
PAIGES OF TIME EARLY LEARNING CENTER
207 KENT AVE
TM 0113 G 0002 P 0056
N/F BERNARD R WINKLER SR TRUST, ET AL
LA PLATA MILL BUILDING SUPPLY & RENTALS
213 KENT AVE
TM 0109 G 0019 P 0080
TM 0113 G 0001 P 0088
TM 0113 G 0001 P 0063
TM 0113 G 0001 P 0087
TM 0113 G 0001 P 0086
AREA OF STEEP SLOPES (>15%, TYP)
F1 F2
F3F4
TM 0113 G 0001 P 0085
G8
TM 0113 G 0001 P 0064
SOILS DATA TABLE
SYMBOL DESCRIPTION HSG Kw HYDRIC
BaB Beltsville Silt Loam, 2-5% C 0.37 No
BaC Beltsville Silt Loam, 5-10% C 0.43* No
BuB Beltsville Urban Land Complex, 2-5% C 0.37 No
UK Urban Land D - No
* SOILS WITH "K" > 0.40 ARE OFTEN CLASSIFIED AS HIGHLY ERODIBLE
40" MAPLE TREE
EX. BMP
HertlingB Text Box
HertlingB Text Box Appendix C - Demolition of 206A Washington Avenue & Site Restoration
HertlingB Rectangle
HertlingB Arrow
HertlingB Arrow
HertlingB Text Box Scope of Work
Remove and dispose of all loose items located within the residence and outbuilding.
Remove and dispose of all fixed items located in and around the residence and outbuilding.
Coordinate with all relevant utility providers to ensure complete disconnection of services prior to demolition activities.
Cut and cap all utilities as directed by each utility providers and mark all locations on this drawing for As-Built purposes.
Remove underground utilities from point of disconnect back to the buildings.
Remove and handle all hazardous materials identified in D2 - Pre-Demo Hazardous Materials Survey Report in compliance with federal, state, and local laws and regulations. Provide disposal manifests.
Demolish and dispose of all building structures, including basement and foundations.
Backfill all disturbed areas with approved materials in compliance with Charles County Standard Specifications. Include soil testing and reporting as required.
Grade the site to achieve a minimum positive slope of 2%, and stabilize all disturbed areas per Charles County Standard Specifications.
44 McPherson Road
Annapolis, MD 21401
410-544-6000
0 44 McPherson Road - Annapolis, MD 21401 - Phone: 410-320-2225
PRE-DEMOLITION HAZARDOUS MATERIALS
SURVEY REPORT
206A Washington Avenue LaPlata, Maryland
August 21, 2024
Prepared for:
Mr. Joseph B. Brady
38592 Brett Way, Suite 7 Mechanicsville, MD 20659
Cell (240) 652-3628 Office (301) 290-1333
Fax (301) 290-5222
Prepared by:
International Academy, Inc.
44 McPherson Road Annapolis, MD 21401
IA Project#
BaysD Received Candis received via email on 9/9/24.
410-544-6000
1 44 McPherson Road - Annapolis, MD 21401 - Phone: 410-320-2225
PRE-DEMOLITION ASSESSMENT AND SURVEY
FOR ASBESTOS CONTAINING MATERIALS, LEAD BASED PAINT, ABOVE
GROUND HEATING OIL TANKS, PCB LIGHT BALLASTS AND
TRANSFORMERS, BATTERY OPERATED LIGHTING, AND MERCURY
CONTAINING LIGHT TUBES AND THERMOSTATS
INTRODUCTION
International Academy, Inc. (IA) was retained by Waco, Inc. to conduct a pre-demolition assessment for Hazardous Materials (user defined) requiring abatement prior to the proposed demolition of the single-family house addressed as 206A Washington Avenue, LaPlata, Maryland (herein referred to as SITE). Mr. Jason A. Simpson and Mr. Sean
Gaglione, experienced asbestos and lead paint inspectors representing IA performed the assessment and sample collection on July 18 and July 23, 2024.
DESCRIPTION OF ASSESSMENT
The purpose of this assessment is to aid Waco in the identification of hazardous materials requiring abatement prior to the proposed demolition of the Site. For the purposes of this assessment, “Hazardous Materials” includes asbestos containing materials (ACMs), Lead-
Based Paint (LBP), above ground heating oil tanks, polychlorinated biphenyl (PCB) containing light ballasts, battery operated lighting, and mercury containing fluorescent light tubes and thermostats. Accessible locations of the building’s interior and exterior, excluding roofing materials, were inspected. Appendix A contains the Chain of Custody forms, and the Laboratory Sample Data Sheets for all PLM bulk samples collected.
Appendix B and C contains Lead-Based Paint XRF results and Certifications respectively.
BUILDING DESCRIPTION
The Site consist of a two-story single-family house with an unfinished basement and CMU block foundation. Interior finishes include wall and ceiling drywall, wood, ceramic and linoleum flooring and ceiling texture overtop drywall. The plumbing and heating pipe were insulated with foil wrapped in fiberglass insulation.
410-544-6000
2 44 McPherson Road - Annapolis, MD 21401 - Phone: 410-320-2225
The house contains wood framed windows and doors and vinyl siding. The roof is covered with black asphalt roof shingles. The interior and exterior of the house are painted with a variation of latex and oil-based paint.
ASSESSMENT
Asbestos
As authorized, IA conducted asbestos inspections and collected bulk samples from suspect asbestos-containing materials (ACMs) to conform with Federal regulations requiring an asbestos inspection of a building prior to renovation or demolition, and State of Maryland
(MD) regulations requiring an asbestos inspection prior to issuance of a renovation or demolition permit. The MD regulations pertain to retail, commercial and industrial facilities built before 1986.
The assessment was limited to collecting representative bulk samples of accessible presumed asbestos containing materials (PACMs) identified within the interior and exterior of the Site. The assessment was performed following inspection and sampling guidelines established by the United States Environmental Protection Agency (EPA) Asbestos
Hazardous Emergency Response Act (AHERA); as well as the EPA National Emission
Standards for Hazardous Air Pollutants (NESHAP) regulation for asbestos and in general accordance with ASTM E 2356-18 Standard Practice for Comprehensive Building
Asbestos Surveys.
The inspector identified Homogenous Areas (HA) of suspect ACMs (an area of building material which is visually similar and contiguous) per construction phase in each structure, classified and assessed each suspect ACM, and presumed or sampled each homogenous area of suspect ACM per the referenced guidelines.
IA staff inspected the interior and exterior of the Site for suspect ACMs including thermal system insulation (TSI), surfacing materials (e.g., ceiling and wall textures), and miscellaneous materials (e.g., vinyl floor tiles and mastics). When suspect materials were identified, IA staff collected representative bulk samples from each HA using modified
AHERA sampling protocols. The following suspect materials were sampled:
410-544-6000
3 44 McPherson Road - Annapolis, MD 21401 - Phone: 410-320-2225
Drywall and Joint Compound
Floor Linoleum and Mastic
Ceramic Floor Tile Grout
Ceiling Texture
Exterior Door and Window Caulk
Exterior Window Glazing
Roofing
IA recorded the areas of the building inspected, as well as areas where materials suspected of containing asbestos were located. During the asbestos survey a total of forty-three (43) bulk samples were collected for PLM analysis. The PLM bulk samples were then submitted to Environmental Hazard Services LLC (EHS) for asbestos analysis using United States
Environmental Protection Agency (EPA) Method EPA600/R-93/116. EHS is American
Industrial Hygiene Association and NVLAP accredited laboratories.
Each sample was individually numbered, and sample identification information was entered onto field data sheets. Bulk samples were collected in such a manner as to minimize the potential for fiber release. Building materials that contain asbestos fibers in amounts greater than one percent (1%) are ACMs and are regulated by the Occupational
Safety and Health Administration (OSHA), EPA, and MD. OSHA regulates building materials containing any percent including “trace” levels of asbestos.
The following Asbestos Sampling Summary Table “Table 1”, provides a complete list of sampled suspected ACM:
Asbestos Sampling Summary Table 206A Washington Avenue
La Plata, MD
Sample No.
Suspect Material Description
Location Cond.
Result
(% Asbestos) Friability Notes
CTEX1 Ceiling Texture Living Good NAD Friable -
CTEX2 Ceiling Texture Bathroom Good NAD Friable -
CTEX3 Ceiling Texture Bedroom Good NAD Friable -
L1 Floor Linoleum Kitchen Good NAD Category I
Non-Friable
410-544-6000
4 44 McPherson Road - Annapolis, MD 21401 - Phone: 410-320-2225
Asbestos Sampling Summary Table 206A Washington Avenue
La Plata, MD
Sample No.
Suspect Material Description
Location Cond.
Result
(% Asbestos) Friability Notes
L2 Floor Linoleum Hallway Good NAD Category I
Non-Friable
DWJC1
Drywall and Joint
Compound Living Good
NAD Category II Non-Friable
DWJC2
Drywall and Joint
Compound Rear Bedroom Good
NAD Category II Non-Friable
WC1 Exterior Window Caulk Front Good NAD Category II
Non-Friable
WC2 Exterior Window Caulk Rear Good NAD Category II
Non-Friable
DC1 Exterior Door Caulk Front Good NAD Category II
Non-Friable
DC2 Exterior Door Caulk Rear Good NAD Category II
Non-Friable
RS1 Asphalt Roof Shingle Roof Good NAD Category I
Non-Friable
RS2 Asphalt Roof Shingle Roof Good NAD Category I
Non-Friable
206A-01A Exterior Window Glazing Front Exterior
Window Glazing Good
NAD Category II Non-Friable
206A-01B Exterior Window Glazing Rear Exterior
Window Glazing Good
NAD Category II Non-Friable
NAD=No Asbestos Detected
APPLICABLE ASBESTOS REGULATIONS AND GUIDELINES
Renovation and Demolition EPA/NESHAP Guidelines
The EPA/National Emissions Standards for Hazardous Air Pollutants (NESHAP) regulations for asbestos apply to certain demolition and renovation projects in facilities containing ACM and/or assumed ACM. The NESHAP, 40 Code of Federal Regulations
(CFR) 61, Subparts A and M, rule usually requires that all friable ACM and some categories of non-friable ACM be removed before a building is demolished.
This may require localized removal before or as part of a renovation. For renovation projects where friable ACM will be disturbed, the NESHAP rule may require appropriate work practices or procedures for the control of emissions.
410-544-6000
5 44 McPherson Road - Annapolis, MD 21401 - Phone: 410-320-2225
The following EPA/NESHAP definitions of ACM are very important in interpreting which
NESHAP requirements may apply to the building.
Category I - Friable asbestos-containing material: any material containing more than 1% asbestos that when dry, can be crumbled, pulverized, or reduced to powder by hand pressure.
Category I - Non-friable asbestos containing material: asbestos containing packings, gaskets, resilient floor covering, and asphalt roofing products containing more than 1% asbestos that, when dry, cannot be crumbled, pulverized or reduced to powder by hand pressure.
Category II non-friable asbestos containing material: any material excluding
Category I non-friable ACM, containing more than 1% asbestos that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.
Regulated asbestos containing material (RACM): (1) friable ACM, (2) Category I non-friable ACM that has become friable (3) Category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or (4) Category
II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the materials in the course of demolition or renovation operations regulated by
NESHAP.
Employee Exposure OSHA Standards
OSHA Standard 29 CFR 1910.1001 and 1926.1101 regulates employee exposure to asbestos. The OSHA asbestos standards for general industry and for construction mandate a Permissible Exposure Limit (PEL) of 0.1 fibers (equal to or longer than five (5) micrometers) per cubic centimeter of air (fiber/cc) determined as an eight (8) hour, Time-
Weighted Average (TWA) and an excursion limit of one (1) fiber/cc as a thirty (30)-Minute
TWA.
410-544-6000
6 44 McPherson Road - Annapolis, MD 21401 - Phone: 410-320-2225
Also, for asbestos removal or renovation involving ACM, the Asbestos Construction
Standard (29 CFR 1926.1101) requires that specific procedures be followed, including enclosure of the work area, to control asbestos exposure of the building occupant’s as well as employees involved in abatement or renovation activities.
If ACM is managed in place, the OSHA Asbestos Construction Standard applies to employees who may contact or disturb ACMs during their work shift.
The following are selected OSHA definitions regarding asbestos work:
Class I asbestos work means activities involving the removal of TSI and surfacing
ACM and assumed ACM.
Class II asbestos work means activities involving the removal of ACM which is not thermal system insulation or surfacing material. This includes, but is not limited to, the removal of asbestos-containing wallboard, floor tile and sheeting, roofing and siding shingles, and construction mastics.
Class III asbestos work means repair and maintenance operations, where “ACM”, including TSI and surfacing ACM and assumed ACM, is likely to be disturbed.
Class VI asbestos work means maintenance and custodial activities during which employees contact but do not disturb ACM or assumed ACM and activities to clean up dust, debris and waste resulting in Class I, II and III activities.
Lead Paint Inspection
International Academy, Inc. (IA) completed a visual survey and lead inspection using a portable X-Ray Florescence (XRF) lead analyzer on assessable interior and exterior paint that could be impacted during the demolition activities. Mr. Sean Gaglione, an experienced
State of Maryland lead paint inspector (MD Cert#15040) conducted the inspection, testing and quality review. The Site work was performed on July 23, 2024.
410-544-6000
7 44 McPherson Road - Annapolis, MD 21401 - Phone: 410-320-2225
Survey Methods
IA used a Thermo Scientific Niton XLp, portable X Ray Fluorescence (XRF), lead-in-paint analyzer, model # 300A, serial #96510, to test painted surfaces that are suspected of containing lead. Measurements were made in accordance with the United States
Department of Housing and Urban Development (HUD); Guidelines for the Evaluation and control of Lead-Based Paint Hazards in Housing, June 2012, Second Edition.
The inspection protocol was based upon our approved company inspection protocol and the Department of Housing and Urban Development (HUD) Guidelines for the Evaluation and Control of Lead-Based Paint in Housing, 2012 revision, single-family housing protocol. The HUD Guidelines are considered the state of the art for lead-based paint testing. The HUD Guidelines require specific surfaces to be tested and require specific quality control methods.
HUD requires performing one test on every testing combination (defined to be a unique combination of component, substrate, and room equivalent) and each wall in each room equivalent. Additionally, the Guidelines recommend grouping testing combination systems with likely similar painting histories, such as door frames, jambs, and casings or windowsills, casings, and aprons, together for classification purposes. Note that the definition of LBP includes “any paint, varnish, shellac, or other coating.” Therefore, testing included stained or glazed components (such as ceramic tile or porcelain fixtures) which might not appear to be painted.
Depending upon the precision achieved during each test, the combination is classified as
LBP, high-inconclusive, low-inconclusive, lead-containing, or none detected. LBP is defined to be paint containing equal to or greater than 0.7 (mg/cm2) via XRF or 0.5% lead by weight via paint chip sample analysis.
Lead-containing paint is defined to be paint containing detectable amounts of lead less than the definition of LBP. Results which are too close to the definition of LBP for the instrument to classify are termed inconclusive. Inconclusive ranges are defined by the XRF
Performance Characteristics Sheet (PCS), developed by the EPA for this instrument and every other type of XRF.
410-544-6000
8 44 McPherson Road - Annapolis, MD 21401 - Phone: 410-320-2225
The PCS inconclusive range for this instrument, depending upon the precision achieved is
0.6 - 1.1 mg/cm2. The mid-point of the inconclusive range separates high and low inconclusive ranges.
The XRF was subjected to manufacturer-recommended quality control standardization at the beginning of the inspection. Quality control standardization reported values within the recommended range. Additionally, the XRF was subjected to HUD-required calibration validation at the beginning of the inspection and at the conclusion of the inspection.
Each calibration validation included three tests on National Institute of Standards and
Technology (NIST) standard reference material (SRM) 2573. The average of each set of three quality control tests conformed to the thresholds listed in the PCS, validating the XRF calibration.
Lead-Based Paint (LBP) equal to or greater than 0.7 (mg/cm2) was not identified on the tested interior and exterior painted surfaces of the Site. As such all paint contains less than
0.7 (mg/cm2) of lead and reported in the attached table as “Negative”.
Above Ground Heating Oil Tanks
The IA representative inspected the Site for above ground heating oil tanks. The IA representative did not observe any above ground oil tanks at the Site.
Mercury Components
IA inspected select fluorescent light lamps and wall mounted thermostats within the SITE as these fixtures often contain a small amount of mercury that is regulated under the EPA’s
Resource Conservation and Recovery Act (RCRA) program. IA identified eight (8) fluorescent light tubes within the basement light fixtures. No mercury containing thermostats were observed throughout the Site.
Light Ballasts Batteries
IA inspected select representative light ballasts at the SITE for labels indicating whether they contain PCBs. The inspected light ballasts do not have a manufacture label stating, “No PCBs”. The unlabeled light ballasts are in the basement overhead light fixtures.
410-544-6000
9 44 McPherson Road - Annapolis, MD 21401 - Phone: 410-320-2225
The two (2) unlabeled ballast should be assumed to contain PCBs and disposed of in accordance with the regulations outlined in Volume 40 CFR Part 761.
IA inspected the house for emergency lighting and exit signs. Emergency lighting and exit signs contain batteries. Batteries are classified as hazardous waste and must be properly disposed of in accordance with EPA RCRA regulation. The batteries can be recycled by certain permitted facilities to provide a more beneficial option for disposal.
The IA representative did not observe any emergency exit signs or emergency lighting at the Site.
CONCLUSION AND RECOMMENDATIONS
Asbestos
EHS reported all sampled and analyzed building material to be free of asbestos content…as such all samples are reported as “No Asbestos Detected”.
Assumed ACMs were not identified within the interior or exterior of the Site.
Materials with low concentrations of asbestos (trace to 1%) were not detected within the interior of the Site.
Lead
Lead-Based Paint (LBP) equal to or greater than 0.7 (mg/cm2) was not identified on the tested interior and exterior painted surfaces of the Site. As such all paint contains less than
0.7 (mg/cm2) of lead and reported in the attached table as “Negative”.
Above Ground Heating Oil Tanks
The IA representative inspected the Site for above ground heating oil tanks. The IA representative did not observe any above ground oil tanks.
410-544-6000
10 44 McPherson Road - Annapolis, MD 21401 - Phone: 410-320-2225
Mercury Components
IA representative identified eight (8) four foot mercury containing light tubes within the basement overhead lighting. The light tubes are 4’ in length. Mercury-containing bulbs/light tubes are subject to the EPA RCRA program, which requires generators of solid waste to determine whether the waste is hazardous. The lamps can be recycled by certain permitted facilities to provide a more beneficial option for disposal. The photograph below illustrates the typical 4’ mercury containing light tube.
PCB Light Ballast
IA inspected select representative light ballasts at the SITE for labels indicating whether they contain PCBs. The inspected light ballasts do not have a manufacture label stating, “No PCBs”. The unlabeled light ballasts are in the basement overhead light fixtures. The two (2) unlabeled ballast should be assumed to contain PCBs and disposed of in accordance with the regulations outlined in Volume 40 CFR Part 761.
410-544-6000
11 44 McPherson Road - Annapolis, MD 21401 - Phone: 410-320-2225
Emergency Lighting and Exit Sign Batteries
The IA representative did not observe any emergency exit signs or lighting at the Site.
IA is pleased to have provided this inspection. If questions or comments concerning this report arise, please contact me at 410-320-2225.
Sincerely, International Academy, Inc.
Jason A. Simpson
Project Manager
410-544-6000
Appendix A
Laboratory Results and COC Forms
Asbestos Bulk Analysis Report
Client:
Report Number:
Project/Test Address:
Client Number:
Reported Date:
Received Date:
Analyzed Date:
International Academy Inc. 07/24/2024
21-2257
07/26/2024
24-07-04115
206 A Washington Ave; La Plata, MD
Laboratory Results Fax Number:
410-544-6000
44 McPherson Road Annapolis, MD 21401
07/25/2024
Layer Type AsbestosClient Sample Number
Other Materials
Lab Gross DescriptionLab Sample Number
7469 Whitepine Rd
Telephone: 800.347.4010
North Chesterfield, VA 23237
Off-White Chalky; Brown Fibrous; Inhomogeneous
24-07-04115-001 CTEX1 25% Cellulose 75% Non-Fibrous
NAD
Off-White Chalky; Brown Fibrous; Inhomogeneous
24-07-04115-002 CTEX2 25% Cellulose 75% Non-Fibrous
NAD
Off-White Chalky; Brown Fibrous; Inhomogeneous
24-07-04115-003 CTEX3 28% Cellulose 72% Non-Fibrous
NAD
Beige/White Vinyl; Gray Fibrous; Inhomogeneous
24-07-04115-004A L1 40% Cellulose 10% Synthetic 50% Non-Fibrous
Linoleum NAD
Brown Adhesive;
Homogeneous
24-07-04115-004B L1 2% Cellulose 2% Synthetic 96% Non-Fibrous
Mastic NAD
1 of 4Page
Beige/White Vinyl; Gray Fibrous; Inhomogeneous
24-07-04115-005 L2 40% Cellulose 10% Synthetic 50% Non-Fibrous
NAD
No mastic present
Gray/White Chalky; Brown Fibrous; Yellow Paint;
Inhomogeneous
24-07-04115-006 DWJC1 18% Cellulose 82% Non-Fibrous
NAD
Gray/White Chalky; Brown Fibrous; Yellow Paint;
Inhomogeneous
24-07-04115-007 DWJC2 20% Cellulose 80% Non-Fibrous
NAD
Off-White Rubbery; Brown Fibrous; Beige Paint;
Inhomogeneous
24-07-04115-008A WC1 15% Cellulose 85% Non-Fibrous
Caulk NAD
Beige Brittle;
Homogeneous
24-07-04115-008B WC1 3% Cellulose 5% Wollastonite 92% Non-Fibrous
Glazing NAD
Off-White Rubbery; Brown Fibrous; Blue Paint;
Inhomogeneous
24-07-04115-009A WC2 20% Cellulose 80% Non-Fibrous
Caulk NAD
Beige Brittle;
Homogeneous
24-07-04115-009B WC2 4% Cellulose 5% Wollastonite 91% Non-Fibrous
Glazing NAD
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:21-2257 24-07-04115
206 A Washington Ave; La Plata, MD
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample Number
2 of 4Page
White Rubbery; Brown Fibrous; Beige/Blue Paint;
Inhomogeneous
24-07-04115-010A DC1 10% Cellulose 90% Non-Fibrous
Caulk NAD
Beige Brittle;
Homogeneous
24-07-04115-010B DC1 1% Cellulose 6% Wollastonite 93% Non-Fibrous
Glazing NAD
White Rubbery; Brown Fibrous; Beige/Blue Paint;
Inhomogeneous
24-07-04115-011A DC2 30% Cellulose 70% Non-Fibrous
Caulk NAD
Beige Brittle;
Homogeneous
24-07-04115-011B DC2 1% Cellulose 5% Wollastonite 94% Non-Fibrous
Glazing NAD
Black Tar-like; Gray/Blue Aggregate;
Inhomogeneous
24-07-04115-012 RS1 16% Fibrous Glass 2% Wollastonite 82% Non-Fibrous
NAD
Black Tar-like; Gray/Blue Aggregate;
Inhomogeneous
24-07-04115-013 RS2 18% Fibrous Glass 2% Wollastonite 80% Non-Fibrous
NAD
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:21-2257 24-07-04115
206 A Washington Ave; La Plata, MD
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample Number
3 of 4Page
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:21-2257 24-07-04115
206 A Washington Ave; La Plata, MD
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample Number
Melissa Kanode
1% Asbestos
Analyst:
Reporting Limit:
Method:
QC Blank:
QC Sample:
Joey Rust
EPA Method 600/R-93/116, EPA Method 600/M4-82-020
QA/QC Clerk
Reviewed By Authorized Signatory:
93-M22019-2
SRM 1866 Fiberglass
NAD = no asbestos detectedLEGEND:
These results are based on a comparative visual estimate. The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Each distinct component in an inhomogeneous sample was analyzed separately and reported as a composite.
Results represent the analysis of samples submitted by the client. Sample location, description, area, volume, etc., was provided by the client. This report cannot be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without the written consent of the Environmental Hazards Service, L.L.C. All information concerning sampling location, date, and time can be found on Chain-of-Custody. Environmental Hazards Services, L.L.C. does not perform any sample collection. . NVLAP #101882-0 VELAP 460172
Environmental Hazards Services, L.L.C. recommends reanalysis by point count (for more accurate quantification) or Transmission Electron Microscopy
(TEM), (for enhanced detection capabilities) for materials regulated by EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by polarized light microscopy (PLM). Both services are available for an additional fee.
400 Point Count Analysis, where noted, performed per EPA Method 600/R-93/116 with a Reporting Limit of 0.25%.
4 of 4Page
Asbestos Bulk Analysis Report
Client:
Report Number:
Project/Test Address:
Client Number:
Reported Date:
Received Date:
Analyzed Date:
International Academy Inc. 08/28/2024
21-2257
08/28/2024
24-08-04968
206A Washington Avenue; La Plata, Maryland
Laboratory Results Fax Number:
410-544-6000
44 McPherson Road Annapolis, MD 21401
08/28/2024
Layer Type AsbestosClient Sample Number
Other Materials
Lab Gross DescriptionLab Sample Number
7469 Whitepine Rd
Telephone: 800.347.4010
North Chesterfield, VA 23237
Beige Brittle;
Homogeneous
24-08-04968-001 206A-01A 100% Non-Fibrous-- NAD
Beige Brittle;
Homogeneous
24-08-04968-002 206A-01B 100% Non-Fibrous-- NAD
1 of 2Page
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:21-2257 24-08-04968
206A Washington Avenue; La Plata, Maryland
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample Number
Melissa Kanode
1% Asbestos
Analyst:
Reporting Limit:
Method:
QC Blank:
QC Sample:
Keleigh King
EPA Method 600/R-93/116, EPA Method 600/M4-82-020
QA/QC Clerk
Reviewed By Authorized Signatory:
96-M22012-4
SRM 1866 Fiberglass
NAD = no asbestos detectedLEGEND:
These results are based on a comparative visual estimate. The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Each distinct component in an inhomogeneous sample was analyzed separately and reported as a composite.
Results represent the analysis of samples submitted by the client. Sample location, description, area, volume, etc., was provided by the client. This report cannot be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without the written consent of the Environmental Hazards Service, L.L.C. All information concerning sampling location, date, and time can be found on Chain-of-Custody. Environmental Hazards Services, L.L.C. does not perform any sample collection. . NVLAP #101882-0 VELAP 460172
Environmental Hazards Services, L.L.C. recommends reanalysis by point count (for more accurate quantification) or Transmission Electron Microscopy
(TEM), (for enhanced detection capabilities) for materials regulated by EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by polarized light microscopy (PLM). Both services are available for an additional fee.
400 Point Count Analysis, where noted, performed per EPA Method 600/R-93/116 with a Reporting Limit of 0.25%.
2 of 2Page
410-544-6000
Appendix B
Lead-Paint XRF Results
Location Wall Component Substrate Color Condition XRF Result Classification
206A
Living Room A Wall Drywall Yellow Good 0.0 Negative
A Baseboard Wood N/A Good 0.0 Negative
A Front Door Wood N/A Good 0.0 Negative
A Front Door Casing Wood N/A Good 0.0 Negative
A Front Door Jamb Wood N/A Good 0.0 Negative
A Window Casing Wood N/A Good 0.0 Negative
A Window Frame / Stop Wood N/A Good 0.0 Negative
A Window Sill Wood N/A Good 0.0 Negative
A Window Apron Wood N/A Good 0.0 Negative
C Closet Door Wood N/A Good 0.0 Negative
C Closet Door Casing Wood N/A Good 0.0 Negative
C Closet Door Jamb Wood N/A Good 0.0 Negative
C Kitchen Door Casing Wood N/A Good 0.0 Negative
C Kitchen Door Jamb Wood N/A Good 0.0 Negative
Kitchen A Wall Panel White Good 0.0 Negative
A Chair Rail Wood N/A Good 0.0 Negative
A Baseboard Wood N/A Good 0.0 Negative
A Closet Door Wood N/A Good 0.0 Negative
A Closet Door Casing Wood N/A Good 0.0 Negative
A Closet Door Jamb Wood N/A Good 0.0 Negative
B Closet Door Wood N/A Good 0.0 Negative
B Closet Door Casing Wood N/A Good 0.0 Negative
B Closet Door Jamb Wood N/A Good 0.0 Negative
B Exit Door Wood N/A Good 0.0 Negative
B Exit Door Casing Wood N/A Good 0.0 Negative
B Exit Door Jamb Wood N/A Good 0.0 Negative
C Cabinet Wood N/A Good 0.0 Negative
C Window Casing Wood N/A Good 0.0 Negative
C Window Frame / Stop Wood N/A Good 0.0 Negative
C Window Sill Wood N/A Good 0.0 Negative
C Window Apron Wood N/A Good 0.0 Negative
Hallway A Wall Panel White Good 0.0 Negative
A Baseboard Wood N/A Good 0.0 Negative
A Bedroom 1 Door Wood N/A Good 0.0 Negative
A Bedroom 1 Door Casing Wood N/A Good 0.0 Negative
A Bedroom 1 Door Jamb Wood N/A Good 0.0 Negative
A Bedroom 2 Door Wood N/A Good 0.0 Negative
A Bedroom 2 Door Casing Wood N/A Good 0.0 Negative
A Bedroom 2 Door Jamb Wood N/A Good 0.0 Negative
C Bathroom Door Wood N/A Good 0.0 Negative
C Bathroom Door Casing Wood N/A Good 0.0 Negative
C Bathroom Door Jamb Wood N/A Good 0.0 Negative
C Closet Door Wood N/A Good 0.0 Negative
C Closet Door Casing Wood N/A Good 0.0 Negative
C Closet Door Jamb Wood N/A Good 0.0 Negative
D Bedroom 3 Door Wood N/A Good 0.0 Negative
D Bedroom 3 Door Casing Wood N/A Good 0.0 Negative
D Bedroom 3 Door Jamb Wood N/A Good 0.0 Negative
Bedroom 1 A Wall Drywall Yellow Good 0.0 Negative
A Window Casing Wood N/A Good 0.0 Negative
A Window Frame / Stop Wood N/A Good 0.0 Negative
A Window Sill Wood N/A Good 0.0 Negative
A Window Apron Wood N/A Good 0.0 Negative
A Window Sash Wood N/A Good 0.0 Negative
B Closet Door Wood N/A Good 0.0 Negative
B Closet Door Casing Wood N/A Good 0.0 Negative
B Closet Door Jamb Wood N/A Good 0.0 Negative
Bedroom 2 A Wall Drywall Yellow Good 0.0 Negative
A Window Casing Wood N/A Good 0.0 Negative
A Window Frame / Stop Wood N/A Good 0.0 Negative
A Window Sill Wood N/A Good 0.0 Negative
A Window Sash Wood N/A Good 0.0 Negative
XRF Results for 206A Washington Ave. La Plata, Maryland
International Academy, Inc. Page 1
A Window Apron Wood N/A Good 0.0 Negative
D Closet Door Wood N/A Good 0.0 Negative
D Closet Door Casing Wood N/A Good 0.0 Negative
D Closet Door Jamb Wood N/A Good 0.0 Negative
Bathroom B Wall Drywall White Good 0.0 Negative
B Baseboard Wood N/A Good 0.0 Negative
B Vanity Wood N/A Good 0.0 Negative
Bedroom 3 A Wall Drywall Yellow Good 0.0 Negative
A Baseboard Wood N/A Good 0.0 Negative
A Closet Door Wood N/A Good 0.0 Negative
A Closet Door Casing Wood N/A Good 0.0 Negative
A Closet Door Jamb Wood N/A Good 0.0 Negative
C Window Casing Wood N/A Good 0.0 Negative
C Window Frame / Stop Wood N/A Good 0.0 Negative
C Window Sill Wood N/A Good 0.0 Negative
C Window Apron Wood N/A Good 0.0 Negative
C Window Sash Wood N/A Good 0.0 Negative
Exterior A Façade Wood Blue Good 0.0 Negative
NOTE: Wall A is façade facing Washington Ave., progressing clockwise
Date: July 23rd 2024 Time Result
Pre Calibration 14:10 1.1
Calibration 14:10 1.1
Calibration 14:10 1.1
Calibration 14:10 0.0
Calibration 14:10 0.0
Calibration 14:11 0.0
Post Calibration 14:44 1.1
Calibration 14:45 1.0
Calibration 14:45 1.0
Calibration 14:45 0.0
Calibration 14:45 0.0
Calibration 14:45 0.0
International Academy, Inc. Page 2
410-544-6000
Appendix C
Certifications
Niton XLp 300, 9/24/2004, ed. 1
Performance Characteristic Sheet
EFFECTIVE DATE: September 24, 2004 EDITION NO.: 1
MANUFACTURER AND MODEL:
Make: Niton LLC Tested Model: XLp 300 Source: 109Cd Note: This PCS is also applicable to the equivalent model variations indicated below, for the Lead-in-Paint K+L variable reading time mode, in the XLi and XLp series:
XLi 300A, XLi 301A, XLi 302A and XLi 303A.
XLp 300A, XLp 301A, XLp 302A and XLp 303A.
XLi 700A, XLi 701A, XLi 702A and XLi 703A.
XLp 700A, XLp 701A, XLp 702A, and XLp 703A.
Note: The XLi and XLp versions refer to the shape of the handle part of the instrument. The differences in the model numbers reflect other modes available, in addition to Lead-in- Paint modes. The manufacturer states that specifications for these instruments are identical for the source, detector, and detector electronics relative to the Lead-in-Paint mode.
FIELD OPERATION GUIDANCE
OPERATING PARAMETERS:
Lead-in-Paint K+L variable reading time mode.
XRF CALIBRATION CHECK LIMITS:
0.8 to 1.2 mg/cm2 (inclusive)
The calibration of the XRF instrument should be checked using the paint film nearest 1.0 mg/cm2 in the NIST Standard Reference Material (SRM) used (e.g., for NIST SRM 2579, use the 1.02 mg/cm2 film).
If readings are outside the acceptable calibration check range, follow the manufacturer's instructions to bring the instruments into control before XRF testing proceeds.
SUBSTRATE CORRECTION:
For XRF results using Lead-in-Paint K+L variable reading time mode, substrate correction is not needed for:
Brick, Concrete, Drywall, Metal, Plaster, and Wood
INCONCLUSIVE RANGE OR THRESHOLD:
K+L MODE
READING DESCRIPTION
SUBSTRATE THRESHOLD
(mg/cm2)
Results not corrected for substrate bias on any substrate
Brick Concrete Drywall Metal
Plaster Wood
1.0 1.0 1.0 1.0 1.0 1.0
BACKGROUND INFORMATION
EVALUATION DATA SOURCE AND DATE:
This sheet is supplemental information to be used in conjunction with Chapter 7 of the HUD Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing ("HUD Guidelines"). Performance parameters shown on this sheet are calculated from the EPA/HUD evaluation using archived building components. Testing was conducted in August 2004 on 133 testing combinations. The instruments that were used to perform the testing had new sources; one instrument’s was installed in November 2003 with 40 mCi initial strength, and the other’s was installed June 2004 with 40 mCi initial strength.
OPERATING PARAMETERS:
Performance parameters shown in this sheet are applicable only when properly operating the instrument using the manufacturer's instructions and procedures described in Chapter 7 of the HUD Guidelines.
SUBSTRATE CORRECTION VALUE COMPUTATION:
Substrate correction is not needed for brick, concrete, drywall, metal, plaster or wood when using Lead-in- Paint K+L variable reading time mode, the normal operating mode for these instruments. If substrate correction is desired, refer to Chapter 7 of the HUD Guidelines for guidance on correcting XRF results for substrate bias.
EVALUATING THE QUALITY OF XRF TESTING:
Randomly select ten testing combinations for retesting from each house or from two randomly selected units in multifamily housing. Use the K+L variable time mode readings.
Conduct XRF retesting at the ten testing combinations selected for retesting.
Determine if the XRF testing in the units or house passed or failed the test by applying the steps below.
Compute the Retest Tolerance Limit by the following steps:
Determine XRF results for the original and retest XRF readings. Do not correct the original or retest results for substrate bias. In single-family housing a result is defined as the average of three readings. In multifamily housing, a result is a single reading.
Therefore, there will be ten original and ten retest XRF results for each house or for the two selected units.
Calculate the average of the original XRF result and retest XRF result for each testing combination.
Square the average for each testing combination.
Add the ten squared averages together. Call this quantity C.
Multiply the number C by 0.0072. Call this quantity D.
Add the number 0.032 to D. Call this quantity E.
Take the square root of E. Call this quantity F.
Multiply F by 1.645. The result is the Retest Tolerance Limit.
Compute the average of all ten original XRF results.
Compute the average of all ten re-test XRF results.
Find the absolute difference of the two averages.
If the difference is less than the Retest Tolerance Limit, the inspection has passed the retest. If the difference of the overall averages equals or exceeds the Retest Tolerance Limit, this procedure should be repeated with ten new testing combinations. If the difference of the overall averages is equal to or greater than the Retest Tolerance Limit a second time, then the inspection should be considered deficient.
Use of this procedure is estimated to produce a spurious result approximately 1% of the time. That is, results of this procedure will call for further examination when no examination is warranted in approximately 1 out of 100 dwelling units tested.
TESTING TIMES:
For the Lead-in-Paint K+L variable reading time mode, the instrument continues to read until it is moved away from the testing surface, terminated by the user, or the instrument software indicates the reading is complete. The following table provides testing time information for this testing mode. The times have been adjusted for source decay, normalized to the initial source strengths as noted above. Source strength and type of substrate will affect actual testing times. At the time of testing, the instruments had source strengths of 26.6 and 36.6 mCi.
Testing Times Using K+L Reading Mode (Seconds)
All Data Median for laboratory-measured lead levels (mg/cm2)
Substrate 25th Percentile
Median 75th Percentile
Pb < 0.25 0.25 < Pb<1.0 1.0 < Pb
Wood Drywall
4 11 19 11 15 11
Metal
4 12 18 9 12 14
Brick Concrete Plaster
8 16 22 15 18 16
CLASSIFICATION RESULTS:
XRF results are classified as positive if they are greater than or equal to the threshold, and negative if they are less than the threshold.
DOCUMENTATION:
A document titled Methodology for XRF Performance Characteristic Sheets provides an explanation of the statistical methodology used to construct the data in the sheets, and provides empirical results from using the recommended inconclusive ranges or thresholds for specific XRF instruments. For a copy of this document call the National Lead Information Center Clearinghouse at 1-800-424-LEAD.
This XRF Performance Characteristic Sheet was developed by the Midwest Research Institute (MRI) and QuanTech, Inc., under a contract between MRI and the XRF manufacturer. HUD has determined that the information provided here is acceptable when used as guidance in conjunction with Chapter 7, Lead-Based Paint Inspection, of HUD’s Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing.
Results Maryland Asbestos Accreditation Exam
Certificate Number: 24-281
First Name: Jason Last Name:Simpson
7/18/2024According to our records this test was completed on:
We administered the following asbestos certification exam: Inspector/Man
Score: 83
Address: 44 McPherson Road
City: Annapolis State: MD Zip: 21401
Congratulations you have passed your Maryland asbestos accreditation exam. This document and your training certificate will serve as a temporary license until you receive your official license in the mail. Prior to issuing a license, MDE will verify all necessary information and submitted documents.
necessary information and submitted documents.
Your Results
Issued By_____________ 7/18/2024Date
Thank you for taking the Maryland asbestos accreditation exam. If you have any concerns or questions about the exam, including how to collect your photo ID, please direct them to the Maryland Department of the environment at (410) 537- 3200.
THIS IS TO CERTIFY THAT
Sean Vincent Gaglione
HAS MET THE LEAD PAINT SERVICES
ACCREDITATION REQUIREMENTS FOR
Inspector Technician
START DATE: 07/10/2023 EXPIRY DATE: 07/10/2025
TRAINING PROVIDER: Aerosol Monitoring & Analysis, Inc.
COURSE DATE: 03/02/2023
Certificate # 15040 07/10/2023 ADMINISTRATOR, LEAD PAINT ACCREDITATION Date
MARYLAND DEPARTMENT OF THE ENVIRONMENT
STATE OF MARYLAND
| C - 206A Washington Ave 2507xx |
| Sheets and Views |
| ex cond |
| Appendix_D2_-_Waco_206A_Washington_Ave_Pre_Demolition_Hazmat_Materials_Report_08-21-24 |
| Waco_206A Washington Avenue LaPlata Maryland_Pre Demolition Hazmat Materials Report_S206AJ-082124.pdf |
| Appendix A - Cover Sheet.pdf |
| 24-07-04115.pdf |
| Appendix B- Lead-Paint XRF Results.pdf |
| IA 206A Washington Ave. XRF.pdf |
| Appendix C - Certs.pdf |
| Niton-XLp-300-PerformanceCharacteristic-Sheet-PCS.pdf |
| Simpson , Jason-INMAN-07-18-2024.pdf |
File details come from the government source that posted it. Updated .