206A_Washington_Ave_250821.pdf

PDF 3 MB Posted

Attached to
Demolition of Residential and Commercial Structures
Solicitation number
26-008
Issued by
Charles County, Maryland

About this file

This is a Pre-Demolition Hazardous Materials Survey Report prepared by International Academy, Inc. for 206A Washington Avenue in La Plata, Maryland, conducted on behalf of Waco, Inc. The survey was completed in conjunction with Charles County's demolition project for four structures in the Town of La Plata. The inspection and sampling activities occurred on July 18 and July 23, 2024, with the report dated August 21, 2024. The assessment identified and tested for asbestos-containing materials (ACMs), lead-based paint (LBP), above-ground heating oil tanks, polychlorinated biphenyl (PCB) light ballasts, mercury-containing light tubes, and battery-operated lighting fixtures. A total of 43 bulk samples were collected from suspect asbestos-containing materials and submitted to Environmental Hazard Services LLC for analysis using EPA Method 600/R-93/116. Lead-based paint testing was conducted using portable X-Ray Fluorescence (XRF) analysis on accessible interior and exterior painted surfaces following HUD Guidelines for single-family housing protocols.

The survey results indicate no asbestos was detected in any of the 43 samples analyzed, with all materials tested reporting as "NAD" (No Asbestos Detected). Lead-based paint testing revealed no paint samples containing lead equal to or greater than 0.7 mg/cm², meaning all detected paint contains less than the regulatory threshold and is classified as "Negative." However, the inspection identified eight four-foot mercury-containing fluorescent light tubes in the basement overhead lighting fixtures that require specialized disposal under EPA RCRA regulations, and two unlabeled light ballasts in basement fixtures that must be assumed to contain PCBs and disposed of in accordance with 40 CFR Part 761. No above-ground heating oil tanks or emergency lighting/exit sign batteries were observed at the property. The report concludes that while no asbestos or lead-based paint abatement is required, the identified mercury-containing bulbs and PCB ballasts must be properly removed and disposed of by permitted facilities prior to demolition activities.

View the file

Other files

File Type Posted
Demolition_of_Residential_and_Commercial_Structures_(Addendum_#1_Revision).pdf PDF
Demolition_of_Residential_and_Commercial_Structures.pdf PDF
Permits_Package_250821.pdf PDF
As_Builts_&_Project_Close_Out_Requirements_250821.pdf PDF
Maps_250821.pdf PDF
111_N_Maple_Ave_-_250821.pdf PDF
208_Washington_Ave_-_250821.pdf PDF
206_Washington_Ave_250821.pdf PDF
206A_Washington_Ave_250821.pdf PDF
Special_Provisions_-_Final_-_250821.pdf PDF
Sample_Contract_-_Consecutive_Number_of_Days_Specified.pdf PDF
Performance_Labor_Bonds.pdf PDF
Appendix_C_-_Maps.pdf PDF
Appendix_D3_-_Waco_208_Washington_Ave_Pre_Demolition_Hazmat_Materials_Report_08-21-24.pdf PDF
Appendix_F_-_Permits_Package.pdf PDF
Appendix_D4_-_Waco_111_N_Maple_St_Pre_Demolition_Hazmat_Materials_Report_09-03-24.pdf PDF
Appendix_E_-_As-Built_&_Close-Out_Requirement_Package.pdf PDF
Appendix_D1_-_Waco_206_Washington_Ave_Pre_Demolition_Hazmat_Materials_Report_08-21-24.pdf PDF
B2_-_206A_Washington_Avenue.pdf PDF
B3_-_208_Washington_Avenue.pdf PDF
Appendix_A_-_Special_Provisions_Final.docx DOCX document
Appendix_D2_-_Waco_206A_Washington_Ave_Pre_Demolition_Hazmat_Materials_Report_08-21-24.pdf PDF
Formal_Procurement_Request_Form_-_Demo_of_Structures_for_La_Plata_Library_6-24-25_-_signed.pdf PDF
B1_-_206_Washington_Avenue.pdf PDF
B4_-_111_North_Maple_Avenue.pdf PDF
Subcontractor_Breakdown.xlsx XLSX spreadsheet
La_Plata_Demolition_Bid_Form.docx DOCX document
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N

° 3 7'

1"

W

7.

N84° 41' 50"E

645.13'

S0 3°

1'

7"

E

5.

S88° 01' 58"W

646.21'

S0 3°

1'

7"

E

9.

S0 3°

1'

7"

E

4.

S83° 53' 44"W 40.00'

N04° 00' 14"W 9.00'

N88° 05' 39"W 180.16'

N

° 0 8'

1"

W

5.

' S89° 08' 11"W

220.09'

N

° 0 8'

1"

W

0.

S89° 01' 58"W 408.53'

S0 3°

8'

1"

E

4.

N

° 2 8'

2"

W

.0 0'

N02° 28' 02"W 15.04'

S89° 01' 58"W175.00'

S0 2°

0'

2"

E

.0 0'

UK

BaC

BaB

BaB

BaB BuB

BaB

BuB

190190

190190

160159

187 18

187 188

0 20 40 80 120

SCALE� 1" 40'

W

ASH

IN

G

TO

N

AVE

VAR

IABLE W

ID

TH

R

O W

TALBOT ST

EX. N

O R

TH

M

APLE AVE

LAN

D

S N /F N

EW

YO

R K C

EN

TR

AL R

AILR

O

AD

COURTHOUSE PARKING

COURTHOUSE PARKING

MAREDITH BUILDING

3 STORY OFFICE BUILDING

TM 0113 G 0001 P 0084

N/F 200 WASHINGTON AVE LLC

OFFICE BUILDING

200 WASHINGTON AVE

TM 0113 G 0001 P 0082

N/F RALPH & PAULA

WINKLER

214 WASHINGTON AVE

TM 0113 G 0001 P 0089

N/F GEORGE & MARY

ANN SCOTT

214A WASHINGTON AVE

TM 0113 G 0001 P 0089

N/F LYNNE & FELICA

TAGGART

214B WASHINGTON AVE

TM 0113 G 0001 P 0089

N/F RICHARD & MARGUE BALDUS

217 WASHINGTON AVE

TM 0112 G 0006 P 0099

N/F SOUTHERN

MARYLAND OIL INC

TM 0113 G 0001 P 0066

N/F SOUTHERN MARYLAND OIL INC

109 NORTH MAPLE AVE

TM 0113 G 0001 P 0067

LAND N/F COUNTY

COMMISSIONERS OF

CHARLES COUNTY

TM 0112 G 0006 P 0046

LAND N/F COUNTY

COMMISSIONERS OF

CHARLES COUNTY

TM 0113 G 0001 P 0089

LAND N/F COUNTY

COMMISSIONERS OF

CHARLES COUNTY

TM 0113 G 0001 P 0090

LAND N/F COUNTY

COMMISSIONERS OF

CHARLES COUNTY

COURTHOUSE

TM 0113 G 0001 P 0091

38" MAPLE TREE

20" MAGNOLIA TREE

EX. PRIVATE DRIVE

EX. BMP OUTFALL ELEVATION 182.49EX. BMP OUTFALL ELEVATION 182.49

EX. 2 STORY WINKLER HOUSE

E

0.

N 315600.00 E

0.

N 315600.00

E

0.

N 315000.00

N/F BATTLE CREEK

CONSTRUCTION LLC

202 WASHINGTON AVE

TM 0113 G 0001 P 0083

N/F LA PLATA HOLDINGS, LLC

STORAGE WAREHOUSE

205 KENT AVE

TM 0113 G 0002 P 0058

N/F REYNOLDS PROPERTIES LLC

PAIGES OF TIME EARLY LEARNING CENTER

207 KENT AVE

TM 0113 G 0002 P 0056

N/F BERNARD R WINKLER SR TRUST, ET AL

LA PLATA MILL BUILDING SUPPLY & RENTALS

213 KENT AVE

TM 0109 G 0019 P 0080

TM 0113 G 0001 P 0088

TM 0113 G 0001 P 0063

TM 0113 G 0001 P 0087

TM 0113 G 0001 P 0086

AREA OF STEEP SLOPES (>15%, TYP)

F1 F2

F3F4

TM 0113 G 0001 P 0085

G8

TM 0113 G 0001 P 0064

SOILS DATA TABLE

SYMBOL DESCRIPTION HSG Kw HYDRIC

BaB Beltsville Silt Loam, 2-5% C 0.37 No

BaC Beltsville Silt Loam, 5-10% C 0.43* No

BuB Beltsville Urban Land Complex, 2-5% C 0.37 No

UK Urban Land D - No

* SOILS WITH "K" > 0.40 ARE OFTEN CLASSIFIED AS HIGHLY ERODIBLE

40" MAPLE TREE

EX. BMP

HertlingB Text Box

HertlingB Text Box Appendix C - Demolition of 206A Washington Avenue & Site Restoration

HertlingB Rectangle

HertlingB Arrow

HertlingB Arrow

HertlingB Text Box Scope of Work

Remove and dispose of all loose items located within the residence and outbuilding.

Remove and dispose of all fixed items located in and around the residence and outbuilding.

Coordinate with all relevant utility providers to ensure complete disconnection of services prior to demolition activities.

Cut and cap all utilities as directed by each utility providers and mark all locations on this drawing for As-Built purposes.

Remove underground utilities from point of disconnect back to the buildings.

Remove and handle all hazardous materials identified in D2 - Pre-Demo Hazardous Materials Survey Report in compliance with federal, state, and local laws and regulations. Provide disposal manifests.

Demolish and dispose of all building structures, including basement and foundations.

Backfill all disturbed areas with approved materials in compliance with Charles County Standard Specifications. Include soil testing and reporting as required.

Grade the site to achieve a minimum positive slope of 2%, and stabilize all disturbed areas per Charles County Standard Specifications.

44 McPherson Road

Annapolis, MD 21401

410-544-6000

0 44 McPherson Road - Annapolis, MD 21401 - Phone: 410-320-2225

PRE-DEMOLITION HAZARDOUS MATERIALS

SURVEY REPORT

206A Washington Avenue LaPlata, Maryland

August 21, 2024

Prepared for:

Mr. Joseph B. Brady

38592 Brett Way, Suite 7 Mechanicsville, MD 20659

Cell (240) 652-3628 Office (301) 290-1333

Fax (301) 290-5222

Prepared by:

International Academy, Inc.

44 McPherson Road Annapolis, MD 21401

IA Project#

BaysD Received Candis received via email on 9/9/24.

410-544-6000

1 44 McPherson Road - Annapolis, MD 21401 - Phone: 410-320-2225

PRE-DEMOLITION ASSESSMENT AND SURVEY

FOR ASBESTOS CONTAINING MATERIALS, LEAD BASED PAINT, ABOVE

GROUND HEATING OIL TANKS, PCB LIGHT BALLASTS AND

TRANSFORMERS, BATTERY OPERATED LIGHTING, AND MERCURY

CONTAINING LIGHT TUBES AND THERMOSTATS

INTRODUCTION

International Academy, Inc. (IA) was retained by Waco, Inc. to conduct a pre-demolition assessment for Hazardous Materials (user defined) requiring abatement prior to the proposed demolition of the single-family house addressed as 206A Washington Avenue, LaPlata, Maryland (herein referred to as SITE). Mr. Jason A. Simpson and Mr. Sean

Gaglione, experienced asbestos and lead paint inspectors representing IA performed the assessment and sample collection on July 18 and July 23, 2024.

DESCRIPTION OF ASSESSMENT

The purpose of this assessment is to aid Waco in the identification of hazardous materials requiring abatement prior to the proposed demolition of the Site. For the purposes of this assessment, “Hazardous Materials” includes asbestos containing materials (ACMs), Lead-

Based Paint (LBP), above ground heating oil tanks, polychlorinated biphenyl (PCB) containing light ballasts, battery operated lighting, and mercury containing fluorescent light tubes and thermostats. Accessible locations of the building’s interior and exterior, excluding roofing materials, were inspected. Appendix A contains the Chain of Custody forms, and the Laboratory Sample Data Sheets for all PLM bulk samples collected.

Appendix B and C contains Lead-Based Paint XRF results and Certifications respectively.

BUILDING DESCRIPTION

The Site consist of a two-story single-family house with an unfinished basement and CMU block foundation. Interior finishes include wall and ceiling drywall, wood, ceramic and linoleum flooring and ceiling texture overtop drywall. The plumbing and heating pipe were insulated with foil wrapped in fiberglass insulation.

410-544-6000

2 44 McPherson Road - Annapolis, MD 21401 - Phone: 410-320-2225

The house contains wood framed windows and doors and vinyl siding. The roof is covered with black asphalt roof shingles. The interior and exterior of the house are painted with a variation of latex and oil-based paint.

ASSESSMENT

Asbestos

As authorized, IA conducted asbestos inspections and collected bulk samples from suspect asbestos-containing materials (ACMs) to conform with Federal regulations requiring an asbestos inspection of a building prior to renovation or demolition, and State of Maryland

(MD) regulations requiring an asbestos inspection prior to issuance of a renovation or demolition permit. The MD regulations pertain to retail, commercial and industrial facilities built before 1986.

The assessment was limited to collecting representative bulk samples of accessible presumed asbestos containing materials (PACMs) identified within the interior and exterior of the Site. The assessment was performed following inspection and sampling guidelines established by the United States Environmental Protection Agency (EPA) Asbestos

Hazardous Emergency Response Act (AHERA); as well as the EPA National Emission

Standards for Hazardous Air Pollutants (NESHAP) regulation for asbestos and in general accordance with ASTM E 2356-18 Standard Practice for Comprehensive Building

Asbestos Surveys.

The inspector identified Homogenous Areas (HA) of suspect ACMs (an area of building material which is visually similar and contiguous) per construction phase in each structure, classified and assessed each suspect ACM, and presumed or sampled each homogenous area of suspect ACM per the referenced guidelines.

IA staff inspected the interior and exterior of the Site for suspect ACMs including thermal system insulation (TSI), surfacing materials (e.g., ceiling and wall textures), and miscellaneous materials (e.g., vinyl floor tiles and mastics). When suspect materials were identified, IA staff collected representative bulk samples from each HA using modified

AHERA sampling protocols. The following suspect materials were sampled:

410-544-6000

3 44 McPherson Road - Annapolis, MD 21401 - Phone: 410-320-2225

Drywall and Joint Compound

Floor Linoleum and Mastic

Ceramic Floor Tile Grout

Ceiling Texture

Exterior Door and Window Caulk

Exterior Window Glazing

Roofing

IA recorded the areas of the building inspected, as well as areas where materials suspected of containing asbestos were located. During the asbestos survey a total of forty-three (43) bulk samples were collected for PLM analysis. The PLM bulk samples were then submitted to Environmental Hazard Services LLC (EHS) for asbestos analysis using United States

Environmental Protection Agency (EPA) Method EPA600/R-93/116. EHS is American

Industrial Hygiene Association and NVLAP accredited laboratories.

Each sample was individually numbered, and sample identification information was entered onto field data sheets. Bulk samples were collected in such a manner as to minimize the potential for fiber release. Building materials that contain asbestos fibers in amounts greater than one percent (1%) are ACMs and are regulated by the Occupational

Safety and Health Administration (OSHA), EPA, and MD. OSHA regulates building materials containing any percent including “trace” levels of asbestos.

The following Asbestos Sampling Summary Table “Table 1”, provides a complete list of sampled suspected ACM:

Asbestos Sampling Summary Table 206A Washington Avenue

La Plata, MD

Sample No.

Suspect Material Description

Location Cond.

Result

(% Asbestos) Friability Notes

CTEX1 Ceiling Texture Living Good NAD Friable -

CTEX2 Ceiling Texture Bathroom Good NAD Friable -

CTEX3 Ceiling Texture Bedroom Good NAD Friable -

L1 Floor Linoleum Kitchen Good NAD Category I

Non-Friable

410-544-6000

4 44 McPherson Road - Annapolis, MD 21401 - Phone: 410-320-2225

Asbestos Sampling Summary Table 206A Washington Avenue

La Plata, MD

Sample No.

Suspect Material Description

Location Cond.

Result

(% Asbestos) Friability Notes

L2 Floor Linoleum Hallway Good NAD Category I

Non-Friable

DWJC1

Drywall and Joint

Compound Living Good

NAD Category II Non-Friable

DWJC2

Drywall and Joint

Compound Rear Bedroom Good

NAD Category II Non-Friable

WC1 Exterior Window Caulk Front Good NAD Category II

Non-Friable

WC2 Exterior Window Caulk Rear Good NAD Category II

Non-Friable

DC1 Exterior Door Caulk Front Good NAD Category II

Non-Friable

DC2 Exterior Door Caulk Rear Good NAD Category II

Non-Friable

RS1 Asphalt Roof Shingle Roof Good NAD Category I

Non-Friable

RS2 Asphalt Roof Shingle Roof Good NAD Category I

Non-Friable

206A-01A Exterior Window Glazing Front Exterior

Window Glazing Good

NAD Category II Non-Friable

206A-01B Exterior Window Glazing Rear Exterior

Window Glazing Good

NAD Category II Non-Friable

NAD=No Asbestos Detected

APPLICABLE ASBESTOS REGULATIONS AND GUIDELINES

Renovation and Demolition EPA/NESHAP Guidelines

The EPA/National Emissions Standards for Hazardous Air Pollutants (NESHAP) regulations for asbestos apply to certain demolition and renovation projects in facilities containing ACM and/or assumed ACM. The NESHAP, 40 Code of Federal Regulations

(CFR) 61, Subparts A and M, rule usually requires that all friable ACM and some categories of non-friable ACM be removed before a building is demolished.

This may require localized removal before or as part of a renovation. For renovation projects where friable ACM will be disturbed, the NESHAP rule may require appropriate work practices or procedures for the control of emissions.

410-544-6000

5 44 McPherson Road - Annapolis, MD 21401 - Phone: 410-320-2225

The following EPA/NESHAP definitions of ACM are very important in interpreting which

NESHAP requirements may apply to the building.

Category I - Friable asbestos-containing material: any material containing more than 1% asbestos that when dry, can be crumbled, pulverized, or reduced to powder by hand pressure.

Category I - Non-friable asbestos containing material: asbestos containing packings, gaskets, resilient floor covering, and asphalt roofing products containing more than 1% asbestos that, when dry, cannot be crumbled, pulverized or reduced to powder by hand pressure.

Category II non-friable asbestos containing material: any material excluding

Category I non-friable ACM, containing more than 1% asbestos that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.

Regulated asbestos containing material (RACM): (1) friable ACM, (2) Category I non-friable ACM that has become friable (3) Category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or (4) Category

II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the materials in the course of demolition or renovation operations regulated by

NESHAP.

Employee Exposure OSHA Standards

OSHA Standard 29 CFR 1910.1001 and 1926.1101 regulates employee exposure to asbestos. The OSHA asbestos standards for general industry and for construction mandate a Permissible Exposure Limit (PEL) of 0.1 fibers (equal to or longer than five (5) micrometers) per cubic centimeter of air (fiber/cc) determined as an eight (8) hour, Time-

Weighted Average (TWA) and an excursion limit of one (1) fiber/cc as a thirty (30)-Minute

TWA.

410-544-6000

6 44 McPherson Road - Annapolis, MD 21401 - Phone: 410-320-2225

Also, for asbestos removal or renovation involving ACM, the Asbestos Construction

Standard (29 CFR 1926.1101) requires that specific procedures be followed, including enclosure of the work area, to control asbestos exposure of the building occupant’s as well as employees involved in abatement or renovation activities.

If ACM is managed in place, the OSHA Asbestos Construction Standard applies to employees who may contact or disturb ACMs during their work shift.

The following are selected OSHA definitions regarding asbestos work:

Class I asbestos work means activities involving the removal of TSI and surfacing

ACM and assumed ACM.

Class II asbestos work means activities involving the removal of ACM which is not thermal system insulation or surfacing material. This includes, but is not limited to, the removal of asbestos-containing wallboard, floor tile and sheeting, roofing and siding shingles, and construction mastics.

Class III asbestos work means repair and maintenance operations, where “ACM”, including TSI and surfacing ACM and assumed ACM, is likely to be disturbed.

Class VI asbestos work means maintenance and custodial activities during which employees contact but do not disturb ACM or assumed ACM and activities to clean up dust, debris and waste resulting in Class I, II and III activities.

Lead Paint Inspection

International Academy, Inc. (IA) completed a visual survey and lead inspection using a portable X-Ray Florescence (XRF) lead analyzer on assessable interior and exterior paint that could be impacted during the demolition activities. Mr. Sean Gaglione, an experienced

State of Maryland lead paint inspector (MD Cert#15040) conducted the inspection, testing and quality review. The Site work was performed on July 23, 2024.

410-544-6000

7 44 McPherson Road - Annapolis, MD 21401 - Phone: 410-320-2225

Survey Methods

IA used a Thermo Scientific Niton XLp, portable X Ray Fluorescence (XRF), lead-in-paint analyzer, model # 300A, serial #96510, to test painted surfaces that are suspected of containing lead. Measurements were made in accordance with the United States

Department of Housing and Urban Development (HUD); Guidelines for the Evaluation and control of Lead-Based Paint Hazards in Housing, June 2012, Second Edition.

The inspection protocol was based upon our approved company inspection protocol and the Department of Housing and Urban Development (HUD) Guidelines for the Evaluation and Control of Lead-Based Paint in Housing, 2012 revision, single-family housing protocol. The HUD Guidelines are considered the state of the art for lead-based paint testing. The HUD Guidelines require specific surfaces to be tested and require specific quality control methods.

HUD requires performing one test on every testing combination (defined to be a unique combination of component, substrate, and room equivalent) and each wall in each room equivalent. Additionally, the Guidelines recommend grouping testing combination systems with likely similar painting histories, such as door frames, jambs, and casings or windowsills, casings, and aprons, together for classification purposes. Note that the definition of LBP includes “any paint, varnish, shellac, or other coating.” Therefore, testing included stained or glazed components (such as ceramic tile or porcelain fixtures) which might not appear to be painted.

Depending upon the precision achieved during each test, the combination is classified as

LBP, high-inconclusive, low-inconclusive, lead-containing, or none detected. LBP is defined to be paint containing equal to or greater than 0.7 (mg/cm2) via XRF or 0.5% lead by weight via paint chip sample analysis.

Lead-containing paint is defined to be paint containing detectable amounts of lead less than the definition of LBP. Results which are too close to the definition of LBP for the instrument to classify are termed inconclusive. Inconclusive ranges are defined by the XRF

Performance Characteristics Sheet (PCS), developed by the EPA for this instrument and every other type of XRF.

410-544-6000

8 44 McPherson Road - Annapolis, MD 21401 - Phone: 410-320-2225

The PCS inconclusive range for this instrument, depending upon the precision achieved is

0.6 - 1.1 mg/cm2. The mid-point of the inconclusive range separates high and low inconclusive ranges.

The XRF was subjected to manufacturer-recommended quality control standardization at the beginning of the inspection. Quality control standardization reported values within the recommended range. Additionally, the XRF was subjected to HUD-required calibration validation at the beginning of the inspection and at the conclusion of the inspection.

Each calibration validation included three tests on National Institute of Standards and

Technology (NIST) standard reference material (SRM) 2573. The average of each set of three quality control tests conformed to the thresholds listed in the PCS, validating the XRF calibration.

Lead-Based Paint (LBP) equal to or greater than 0.7 (mg/cm2) was not identified on the tested interior and exterior painted surfaces of the Site. As such all paint contains less than

0.7 (mg/cm2) of lead and reported in the attached table as “Negative”.

Above Ground Heating Oil Tanks

The IA representative inspected the Site for above ground heating oil tanks. The IA representative did not observe any above ground oil tanks at the Site.

Mercury Components

IA inspected select fluorescent light lamps and wall mounted thermostats within the SITE as these fixtures often contain a small amount of mercury that is regulated under the EPA’s

Resource Conservation and Recovery Act (RCRA) program. IA identified eight (8) fluorescent light tubes within the basement light fixtures. No mercury containing thermostats were observed throughout the Site.

Light Ballasts Batteries

IA inspected select representative light ballasts at the SITE for labels indicating whether they contain PCBs. The inspected light ballasts do not have a manufacture label stating, “No PCBs”. The unlabeled light ballasts are in the basement overhead light fixtures.

410-544-6000

9 44 McPherson Road - Annapolis, MD 21401 - Phone: 410-320-2225

The two (2) unlabeled ballast should be assumed to contain PCBs and disposed of in accordance with the regulations outlined in Volume 40 CFR Part 761.

IA inspected the house for emergency lighting and exit signs. Emergency lighting and exit signs contain batteries. Batteries are classified as hazardous waste and must be properly disposed of in accordance with EPA RCRA regulation. The batteries can be recycled by certain permitted facilities to provide a more beneficial option for disposal.

The IA representative did not observe any emergency exit signs or emergency lighting at the Site.

CONCLUSION AND RECOMMENDATIONS

Asbestos

EHS reported all sampled and analyzed building material to be free of asbestos content…as such all samples are reported as “No Asbestos Detected”.

Assumed ACMs were not identified within the interior or exterior of the Site.

Materials with low concentrations of asbestos (trace to 1%) were not detected within the interior of the Site.

Lead

Lead-Based Paint (LBP) equal to or greater than 0.7 (mg/cm2) was not identified on the tested interior and exterior painted surfaces of the Site. As such all paint contains less than

0.7 (mg/cm2) of lead and reported in the attached table as “Negative”.

Above Ground Heating Oil Tanks

The IA representative inspected the Site for above ground heating oil tanks. The IA representative did not observe any above ground oil tanks.

410-544-6000

10 44 McPherson Road - Annapolis, MD 21401 - Phone: 410-320-2225

Mercury Components

IA representative identified eight (8) four foot mercury containing light tubes within the basement overhead lighting. The light tubes are 4’ in length. Mercury-containing bulbs/light tubes are subject to the EPA RCRA program, which requires generators of solid waste to determine whether the waste is hazardous. The lamps can be recycled by certain permitted facilities to provide a more beneficial option for disposal. The photograph below illustrates the typical 4’ mercury containing light tube.

PCB Light Ballast

IA inspected select representative light ballasts at the SITE for labels indicating whether they contain PCBs. The inspected light ballasts do not have a manufacture label stating, “No PCBs”. The unlabeled light ballasts are in the basement overhead light fixtures. The two (2) unlabeled ballast should be assumed to contain PCBs and disposed of in accordance with the regulations outlined in Volume 40 CFR Part 761.

410-544-6000

11 44 McPherson Road - Annapolis, MD 21401 - Phone: 410-320-2225

Emergency Lighting and Exit Sign Batteries

The IA representative did not observe any emergency exit signs or lighting at the Site.

IA is pleased to have provided this inspection. If questions or comments concerning this report arise, please contact me at 410-320-2225.

Sincerely, International Academy, Inc.

Jason A. Simpson

Project Manager

410-544-6000

Appendix A

Laboratory Results and COC Forms

Asbestos Bulk Analysis Report

Client:

Report Number:

Project/Test Address:

Client Number:

Reported Date:

Received Date:

Analyzed Date:

International Academy Inc. 07/24/2024

21-2257

07/26/2024

24-07-04115

206 A Washington Ave; La Plata, MD

Laboratory Results Fax Number:

410-544-6000

44 McPherson Road Annapolis, MD 21401

07/25/2024

Layer Type AsbestosClient Sample Number

Other Materials

Lab Gross DescriptionLab Sample Number

7469 Whitepine Rd

Telephone: 800.347.4010

North Chesterfield, VA 23237

Off-White Chalky; Brown Fibrous; Inhomogeneous

24-07-04115-001 CTEX1 25% Cellulose 75% Non-Fibrous

NAD

Off-White Chalky; Brown Fibrous; Inhomogeneous

24-07-04115-002 CTEX2 25% Cellulose 75% Non-Fibrous

NAD

Off-White Chalky; Brown Fibrous; Inhomogeneous

24-07-04115-003 CTEX3 28% Cellulose 72% Non-Fibrous

NAD

Beige/White Vinyl; Gray Fibrous; Inhomogeneous

24-07-04115-004A L1 40% Cellulose 10% Synthetic 50% Non-Fibrous

Linoleum NAD

Brown Adhesive;

Homogeneous

24-07-04115-004B L1 2% Cellulose 2% Synthetic 96% Non-Fibrous

Mastic NAD

1 of 4Page

Beige/White Vinyl; Gray Fibrous; Inhomogeneous

24-07-04115-005 L2 40% Cellulose 10% Synthetic 50% Non-Fibrous

NAD

No mastic present

Gray/White Chalky; Brown Fibrous; Yellow Paint;

Inhomogeneous

24-07-04115-006 DWJC1 18% Cellulose 82% Non-Fibrous

NAD

Gray/White Chalky; Brown Fibrous; Yellow Paint;

Inhomogeneous

24-07-04115-007 DWJC2 20% Cellulose 80% Non-Fibrous

NAD

Off-White Rubbery; Brown Fibrous; Beige Paint;

Inhomogeneous

24-07-04115-008A WC1 15% Cellulose 85% Non-Fibrous

Caulk NAD

Beige Brittle;

Homogeneous

24-07-04115-008B WC1 3% Cellulose 5% Wollastonite 92% Non-Fibrous

Glazing NAD

Off-White Rubbery; Brown Fibrous; Blue Paint;

Inhomogeneous

24-07-04115-009A WC2 20% Cellulose 80% Non-Fibrous

Caulk NAD

Beige Brittle;

Homogeneous

24-07-04115-009B WC2 4% Cellulose 5% Wollastonite 91% Non-Fibrous

Glazing NAD

Environmental Hazards Services, L.L.C

Project/Test Address:

Client Number: Report Number:21-2257 24-07-04115

206 A Washington Ave; La Plata, MD

Other Materials

AsbestosLab Sample Number

Layer Type Lab Gross DescriptionClient Sample Number

2 of 4Page

White Rubbery; Brown Fibrous; Beige/Blue Paint;

Inhomogeneous

24-07-04115-010A DC1 10% Cellulose 90% Non-Fibrous

Caulk NAD

Beige Brittle;

Homogeneous

24-07-04115-010B DC1 1% Cellulose 6% Wollastonite 93% Non-Fibrous

Glazing NAD

White Rubbery; Brown Fibrous; Beige/Blue Paint;

Inhomogeneous

24-07-04115-011A DC2 30% Cellulose 70% Non-Fibrous

Caulk NAD

Beige Brittle;

Homogeneous

24-07-04115-011B DC2 1% Cellulose 5% Wollastonite 94% Non-Fibrous

Glazing NAD

Black Tar-like; Gray/Blue Aggregate;

Inhomogeneous

24-07-04115-012 RS1 16% Fibrous Glass 2% Wollastonite 82% Non-Fibrous

NAD

Black Tar-like; Gray/Blue Aggregate;

Inhomogeneous

24-07-04115-013 RS2 18% Fibrous Glass 2% Wollastonite 80% Non-Fibrous

NAD

Environmental Hazards Services, L.L.C

Project/Test Address:

Client Number: Report Number:21-2257 24-07-04115

206 A Washington Ave; La Plata, MD

Other Materials

AsbestosLab Sample Number

Layer Type Lab Gross DescriptionClient Sample Number

3 of 4Page

Environmental Hazards Services, L.L.C

Project/Test Address:

Client Number: Report Number:21-2257 24-07-04115

206 A Washington Ave; La Plata, MD

Other Materials

AsbestosLab Sample Number

Layer Type Lab Gross DescriptionClient Sample Number

Melissa Kanode

1% Asbestos

Analyst:

Reporting Limit:

Method:

QC Blank:

QC Sample:

Joey Rust

EPA Method 600/R-93/116, EPA Method 600/M4-82-020

QA/QC Clerk

Reviewed By Authorized Signatory:

93-M22019-2

SRM 1866 Fiberglass

NAD = no asbestos detectedLEGEND:

These results are based on a comparative visual estimate. The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Each distinct component in an inhomogeneous sample was analyzed separately and reported as a composite.

Results represent the analysis of samples submitted by the client. Sample location, description, area, volume, etc., was provided by the client. This report cannot be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without the written consent of the Environmental Hazards Service, L.L.C. All information concerning sampling location, date, and time can be found on Chain-of-Custody. Environmental Hazards Services, L.L.C. does not perform any sample collection. . NVLAP #101882-0 VELAP 460172

Environmental Hazards Services, L.L.C. recommends reanalysis by point count (for more accurate quantification) or Transmission Electron Microscopy

(TEM), (for enhanced detection capabilities) for materials regulated by EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by polarized light microscopy (PLM). Both services are available for an additional fee.

400 Point Count Analysis, where noted, performed per EPA Method 600/R-93/116 with a Reporting Limit of 0.25%.

4 of 4Page

Asbestos Bulk Analysis Report

Client:

Report Number:

Project/Test Address:

Client Number:

Reported Date:

Received Date:

Analyzed Date:

International Academy Inc. 08/28/2024

21-2257

08/28/2024

24-08-04968

206A Washington Avenue; La Plata, Maryland

Laboratory Results Fax Number:

410-544-6000

44 McPherson Road Annapolis, MD 21401

08/28/2024

Layer Type AsbestosClient Sample Number

Other Materials

Lab Gross DescriptionLab Sample Number

7469 Whitepine Rd

Telephone: 800.347.4010

North Chesterfield, VA 23237

Beige Brittle;

Homogeneous

24-08-04968-001 206A-01A 100% Non-Fibrous-- NAD

Beige Brittle;

Homogeneous

24-08-04968-002 206A-01B 100% Non-Fibrous-- NAD

1 of 2Page

Environmental Hazards Services, L.L.C

Project/Test Address:

Client Number: Report Number:21-2257 24-08-04968

206A Washington Avenue; La Plata, Maryland

Other Materials

AsbestosLab Sample Number

Layer Type Lab Gross DescriptionClient Sample Number

Melissa Kanode

1% Asbestos

Analyst:

Reporting Limit:

Method:

QC Blank:

QC Sample:

Keleigh King

EPA Method 600/R-93/116, EPA Method 600/M4-82-020

QA/QC Clerk

Reviewed By Authorized Signatory:

96-M22012-4

SRM 1866 Fiberglass

NAD = no asbestos detectedLEGEND:

These results are based on a comparative visual estimate. The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Each distinct component in an inhomogeneous sample was analyzed separately and reported as a composite.

Results represent the analysis of samples submitted by the client. Sample location, description, area, volume, etc., was provided by the client. This report cannot be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without the written consent of the Environmental Hazards Service, L.L.C. All information concerning sampling location, date, and time can be found on Chain-of-Custody. Environmental Hazards Services, L.L.C. does not perform any sample collection. . NVLAP #101882-0 VELAP 460172

Environmental Hazards Services, L.L.C. recommends reanalysis by point count (for more accurate quantification) or Transmission Electron Microscopy

(TEM), (for enhanced detection capabilities) for materials regulated by EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by polarized light microscopy (PLM). Both services are available for an additional fee.

400 Point Count Analysis, where noted, performed per EPA Method 600/R-93/116 with a Reporting Limit of 0.25%.

2 of 2Page

410-544-6000

Appendix B

Lead-Paint XRF Results

Location Wall Component Substrate Color Condition XRF Result Classification

206A

Living Room A Wall Drywall Yellow Good 0.0 Negative

A Baseboard Wood N/A Good 0.0 Negative

A Front Door Wood N/A Good 0.0 Negative

A Front Door Casing Wood N/A Good 0.0 Negative

A Front Door Jamb Wood N/A Good 0.0 Negative

A Window Casing Wood N/A Good 0.0 Negative

A Window Frame / Stop Wood N/A Good 0.0 Negative

A Window Sill Wood N/A Good 0.0 Negative

A Window Apron Wood N/A Good 0.0 Negative

C Closet Door Wood N/A Good 0.0 Negative

C Closet Door Casing Wood N/A Good 0.0 Negative

C Closet Door Jamb Wood N/A Good 0.0 Negative

C Kitchen Door Casing Wood N/A Good 0.0 Negative

C Kitchen Door Jamb Wood N/A Good 0.0 Negative

Kitchen A Wall Panel White Good 0.0 Negative

A Chair Rail Wood N/A Good 0.0 Negative

A Baseboard Wood N/A Good 0.0 Negative

A Closet Door Wood N/A Good 0.0 Negative

A Closet Door Casing Wood N/A Good 0.0 Negative

A Closet Door Jamb Wood N/A Good 0.0 Negative

B Closet Door Wood N/A Good 0.0 Negative

B Closet Door Casing Wood N/A Good 0.0 Negative

B Closet Door Jamb Wood N/A Good 0.0 Negative

B Exit Door Wood N/A Good 0.0 Negative

B Exit Door Casing Wood N/A Good 0.0 Negative

B Exit Door Jamb Wood N/A Good 0.0 Negative

C Cabinet Wood N/A Good 0.0 Negative

C Window Casing Wood N/A Good 0.0 Negative

C Window Frame / Stop Wood N/A Good 0.0 Negative

C Window Sill Wood N/A Good 0.0 Negative

C Window Apron Wood N/A Good 0.0 Negative

Hallway A Wall Panel White Good 0.0 Negative

A Baseboard Wood N/A Good 0.0 Negative

A Bedroom 1 Door Wood N/A Good 0.0 Negative

A Bedroom 1 Door Casing Wood N/A Good 0.0 Negative

A Bedroom 1 Door Jamb Wood N/A Good 0.0 Negative

A Bedroom 2 Door Wood N/A Good 0.0 Negative

A Bedroom 2 Door Casing Wood N/A Good 0.0 Negative

A Bedroom 2 Door Jamb Wood N/A Good 0.0 Negative

C Bathroom Door Wood N/A Good 0.0 Negative

C Bathroom Door Casing Wood N/A Good 0.0 Negative

C Bathroom Door Jamb Wood N/A Good 0.0 Negative

C Closet Door Wood N/A Good 0.0 Negative

C Closet Door Casing Wood N/A Good 0.0 Negative

C Closet Door Jamb Wood N/A Good 0.0 Negative

D Bedroom 3 Door Wood N/A Good 0.0 Negative

D Bedroom 3 Door Casing Wood N/A Good 0.0 Negative

D Bedroom 3 Door Jamb Wood N/A Good 0.0 Negative

Bedroom 1 A Wall Drywall Yellow Good 0.0 Negative

A Window Casing Wood N/A Good 0.0 Negative

A Window Frame / Stop Wood N/A Good 0.0 Negative

A Window Sill Wood N/A Good 0.0 Negative

A Window Apron Wood N/A Good 0.0 Negative

A Window Sash Wood N/A Good 0.0 Negative

B Closet Door Wood N/A Good 0.0 Negative

B Closet Door Casing Wood N/A Good 0.0 Negative

B Closet Door Jamb Wood N/A Good 0.0 Negative

Bedroom 2 A Wall Drywall Yellow Good 0.0 Negative

A Window Casing Wood N/A Good 0.0 Negative

A Window Frame / Stop Wood N/A Good 0.0 Negative

A Window Sill Wood N/A Good 0.0 Negative

A Window Sash Wood N/A Good 0.0 Negative

XRF Results for 206A Washington Ave. La Plata, Maryland

International Academy, Inc. Page 1

A Window Apron Wood N/A Good 0.0 Negative

D Closet Door Wood N/A Good 0.0 Negative

D Closet Door Casing Wood N/A Good 0.0 Negative

D Closet Door Jamb Wood N/A Good 0.0 Negative

Bathroom B Wall Drywall White Good 0.0 Negative

B Baseboard Wood N/A Good 0.0 Negative

B Vanity Wood N/A Good 0.0 Negative

Bedroom 3 A Wall Drywall Yellow Good 0.0 Negative

A Baseboard Wood N/A Good 0.0 Negative

A Closet Door Wood N/A Good 0.0 Negative

A Closet Door Casing Wood N/A Good 0.0 Negative

A Closet Door Jamb Wood N/A Good 0.0 Negative

C Window Casing Wood N/A Good 0.0 Negative

C Window Frame / Stop Wood N/A Good 0.0 Negative

C Window Sill Wood N/A Good 0.0 Negative

C Window Apron Wood N/A Good 0.0 Negative

C Window Sash Wood N/A Good 0.0 Negative

Exterior A Façade Wood Blue Good 0.0 Negative

NOTE: Wall A is façade facing Washington Ave., progressing clockwise

Date: July 23rd 2024 Time Result

Pre Calibration 14:10 1.1

Calibration 14:10 1.1

Calibration 14:10 1.1

Calibration 14:10 0.0

Calibration 14:10 0.0

Calibration 14:11 0.0

Post Calibration 14:44 1.1

Calibration 14:45 1.0

Calibration 14:45 1.0

Calibration 14:45 0.0

Calibration 14:45 0.0

Calibration 14:45 0.0

International Academy, Inc. Page 2

410-544-6000

Appendix C

Certifications

Niton XLp 300, 9/24/2004, ed. 1

Performance Characteristic Sheet

EFFECTIVE DATE: September 24, 2004 EDITION NO.: 1

MANUFACTURER AND MODEL:

Make: Niton LLC Tested Model: XLp 300 Source: 109Cd Note: This PCS is also applicable to the equivalent model variations indicated below, for the Lead-in-Paint K+L variable reading time mode, in the XLi and XLp series:

XLi 300A, XLi 301A, XLi 302A and XLi 303A.

XLp 300A, XLp 301A, XLp 302A and XLp 303A.

XLi 700A, XLi 701A, XLi 702A and XLi 703A.

XLp 700A, XLp 701A, XLp 702A, and XLp 703A.

Note: The XLi and XLp versions refer to the shape of the handle part of the instrument. The differences in the model numbers reflect other modes available, in addition to Lead-in- Paint modes. The manufacturer states that specifications for these instruments are identical for the source, detector, and detector electronics relative to the Lead-in-Paint mode.

FIELD OPERATION GUIDANCE

OPERATING PARAMETERS:

Lead-in-Paint K+L variable reading time mode.

XRF CALIBRATION CHECK LIMITS:

0.8 to 1.2 mg/cm2 (inclusive)

The calibration of the XRF instrument should be checked using the paint film nearest 1.0 mg/cm2 in the NIST Standard Reference Material (SRM) used (e.g., for NIST SRM 2579, use the 1.02 mg/cm2 film).

If readings are outside the acceptable calibration check range, follow the manufacturer's instructions to bring the instruments into control before XRF testing proceeds.

SUBSTRATE CORRECTION:

For XRF results using Lead-in-Paint K+L variable reading time mode, substrate correction is not needed for:

Brick, Concrete, Drywall, Metal, Plaster, and Wood

INCONCLUSIVE RANGE OR THRESHOLD:

K+L MODE

READING DESCRIPTION

SUBSTRATE THRESHOLD

(mg/cm2)

Results not corrected for substrate bias on any substrate

Brick Concrete Drywall Metal

Plaster Wood

1.0 1.0 1.0 1.0 1.0 1.0

BACKGROUND INFORMATION

EVALUATION DATA SOURCE AND DATE:

This sheet is supplemental information to be used in conjunction with Chapter 7 of the HUD Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing ("HUD Guidelines"). Performance parameters shown on this sheet are calculated from the EPA/HUD evaluation using archived building components. Testing was conducted in August 2004 on 133 testing combinations. The instruments that were used to perform the testing had new sources; one instrument’s was installed in November 2003 with 40 mCi initial strength, and the other’s was installed June 2004 with 40 mCi initial strength.

OPERATING PARAMETERS:

Performance parameters shown in this sheet are applicable only when properly operating the instrument using the manufacturer's instructions and procedures described in Chapter 7 of the HUD Guidelines.

SUBSTRATE CORRECTION VALUE COMPUTATION:

Substrate correction is not needed for brick, concrete, drywall, metal, plaster or wood when using Lead-in- Paint K+L variable reading time mode, the normal operating mode for these instruments. If substrate correction is desired, refer to Chapter 7 of the HUD Guidelines for guidance on correcting XRF results for substrate bias.

EVALUATING THE QUALITY OF XRF TESTING:

Randomly select ten testing combinations for retesting from each house or from two randomly selected units in multifamily housing. Use the K+L variable time mode readings.

Conduct XRF retesting at the ten testing combinations selected for retesting.

Determine if the XRF testing in the units or house passed or failed the test by applying the steps below.

Compute the Retest Tolerance Limit by the following steps:

Determine XRF results for the original and retest XRF readings. Do not correct the original or retest results for substrate bias. In single-family housing a result is defined as the average of three readings. In multifamily housing, a result is a single reading.

Therefore, there will be ten original and ten retest XRF results for each house or for the two selected units.

Calculate the average of the original XRF result and retest XRF result for each testing combination.

Square the average for each testing combination.

Add the ten squared averages together. Call this quantity C.

Multiply the number C by 0.0072. Call this quantity D.

Add the number 0.032 to D. Call this quantity E.

Take the square root of E. Call this quantity F.

Multiply F by 1.645. The result is the Retest Tolerance Limit.

Compute the average of all ten original XRF results.

Compute the average of all ten re-test XRF results.

Find the absolute difference of the two averages.

If the difference is less than the Retest Tolerance Limit, the inspection has passed the retest. If the difference of the overall averages equals or exceeds the Retest Tolerance Limit, this procedure should be repeated with ten new testing combinations. If the difference of the overall averages is equal to or greater than the Retest Tolerance Limit a second time, then the inspection should be considered deficient.

Use of this procedure is estimated to produce a spurious result approximately 1% of the time. That is, results of this procedure will call for further examination when no examination is warranted in approximately 1 out of 100 dwelling units tested.

TESTING TIMES:

For the Lead-in-Paint K+L variable reading time mode, the instrument continues to read until it is moved away from the testing surface, terminated by the user, or the instrument software indicates the reading is complete. The following table provides testing time information for this testing mode. The times have been adjusted for source decay, normalized to the initial source strengths as noted above. Source strength and type of substrate will affect actual testing times. At the time of testing, the instruments had source strengths of 26.6 and 36.6 mCi.

Testing Times Using K+L Reading Mode (Seconds)

All Data Median for laboratory-measured lead levels (mg/cm2)

Substrate 25th Percentile

Median 75th Percentile

Pb < 0.25 0.25 < Pb<1.0 1.0 < Pb

Wood Drywall

4 11 19 11 15 11

Metal

4 12 18 9 12 14

Brick Concrete Plaster

8 16 22 15 18 16

CLASSIFICATION RESULTS:

XRF results are classified as positive if they are greater than or equal to the threshold, and negative if they are less than the threshold.

DOCUMENTATION:

A document titled Methodology for XRF Performance Characteristic Sheets provides an explanation of the statistical methodology used to construct the data in the sheets, and provides empirical results from using the recommended inconclusive ranges or thresholds for specific XRF instruments. For a copy of this document call the National Lead Information Center Clearinghouse at 1-800-424-LEAD.

This XRF Performance Characteristic Sheet was developed by the Midwest Research Institute (MRI) and QuanTech, Inc., under a contract between MRI and the XRF manufacturer. HUD has determined that the information provided here is acceptable when used as guidance in conjunction with Chapter 7, Lead-Based Paint Inspection, of HUD’s Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing.

Results Maryland Asbestos Accreditation Exam

Certificate Number: 24-281

First Name: Jason Last Name:Simpson

7/18/2024According to our records this test was completed on:

We administered the following asbestos certification exam: Inspector/Man

Score: 83

Address: 44 McPherson Road

City: Annapolis State: MD Zip: 21401

Congratulations you have passed your Maryland asbestos accreditation exam. This document and your training certificate will serve as a temporary license until you receive your official license in the mail. Prior to issuing a license, MDE will verify all necessary information and submitted documents.

necessary information and submitted documents.

Your Results

Issued By_____________ 7/18/2024Date

Thank you for taking the Maryland asbestos accreditation exam. If you have any concerns or questions about the exam, including how to collect your photo ID, please direct them to the Maryland Department of the environment at (410) 537- 3200.

THIS IS TO CERTIFY THAT

Sean Vincent Gaglione

HAS MET THE LEAD PAINT SERVICES

ACCREDITATION REQUIREMENTS FOR

Inspector Technician

START DATE: 07/10/2023 EXPIRY DATE: 07/10/2025

TRAINING PROVIDER: Aerosol Monitoring & Analysis, Inc.

COURSE DATE: 03/02/2023

Certificate # 15040 07/10/2023 ADMINISTRATOR, LEAD PAINT ACCREDITATION Date

MARYLAND DEPARTMENT OF THE ENVIRONMENT

STATE OF MARYLAND

C - 206A Washington Ave 2507xx
Sheets and Views
ex cond
Appendix_D2_-_Waco_206A_Washington_Ave_Pre_Demolition_Hazmat_Materials_Report_08-21-24
Waco_206A Washington Avenue LaPlata Maryland_Pre Demolition Hazmat Materials Report_S206AJ-082124.pdf
Appendix A - Cover Sheet.pdf
24-07-04115.pdf
Appendix B- Lead-Paint XRF Results.pdf
IA 206A Washington Ave. XRF.pdf
Appendix C - Certs.pdf
Niton-XLp-300-PerformanceCharacteristic-Sheet-PCS.pdf
Simpson , Jason-INMAN-07-18-2024.pdf

File details come from the government source that posted it. Updated .