This document is a comprehensive set of construction plan drawings for the Cuthbert Amphitheater Site Improvements project in Eugene, Oregon, prepared for the City of Eugene. The project encompasses extensive civil engineering, landscape architecture, and electrical work to improve the amphitheater facilities and surrounding grounds. The plans include site demolition and clearing, parking lot and entry plaza construction, grading and stormwater management, utility installation, landscape planting with irrigation systems, and electrical infrastructure including lighting poles, power pedestals for buses and food carts, and a new service cabinet pedestal. The construction drawings are organized into multiple sheets covering existing conditions surveys, erosion and sediment control plans, pre- and post-construction management, site plans for the parking lot and amphitheater areas, surfacing plans, utility routing, landscape details, and electrical specifications. The project involves coordination with the Eugene Water and Electric Board (EWEB) for utility service installation and requires contractor compliance with tree protection measures, stormwater management standards, and electrical code requirements. Sealed bids for this project are due to the City of Eugene Purchasing Office by Tuesday, August 25, 2026, at 2:30 p.m.
The electrical work specified includes installation of pole-mounted LED luminaires (KIM Lighting ERA RA Series in 14' and 16' heights), five bus power pedestals and four food cart power pedestals rated for 50-amp service, parking lot lighting circuits, and a 400-amp service entrance cabinet with CT meter rated for 22,000 amperes interrupting capacity at 120/240 volts. The construction site management plan outlines pre- and post-construction erosion control measures, tree removal protocols, and inspection frequency requirements. The landscape design incorporates native plantings with an integrated irrigation system and detention pond management. All electrical work must comply with the National Electrical Code (NEC), utilize conduit and conductor sizing per schedule specifications, and include vandal-resistant junction box covers. The contractor must coordinate underground conduit routing to avoid conflicts with existing and proposed trees and minimize landscaping impacts, with all electrical installations subject to EWEB approval and utility company specifications for service installation.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EN
G
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
C O
V E
R S
H E
E T
W
IT
H S
IT
E
A N
D V
IC
IN
IT
Y
M A
P S
C000
PROPERTY DESCRIPTION:
CUTHBERT AMPHITHEATER IMPROVEMENTS
VERTICAL DATUM
PROJECT RECORD DRAWING
VICINITY MAP
ATTENTION EXCAVATORS:
SITE MAP
CIVIL ENGINEERING CONSTRUCTION PLANS
Know what's below.
before you dig.Call
R
SANITARY SEWER
CIVIL ENGINEERING OWNER/APPLICANT
EUGENE WATER AND
ELECTRIC BOARD
LEGEND
SHEET INDEX
DIGITALLY SIGNED
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
G E
N E
R A
L C
O N
S T
R U
C T
IO
N
N O
T E
S
C001A
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
G E
N E
R A
L C
O N
S T
R U
C T
IO
N
N O
T E
S
C001B copyright © 2025 Branch Engineering, Inc.
sheet:
revisions:
designer:
drawn by:
project no:
project title:
date:
E X
IS
T
IN
G
C O
N D
IT
IO
N S S
U R
V E Y
F O
R C
IT
Y
O F E
U G
E N
E civil transportation structural geotechnical
SURVEYING
310 5th Street
Springfield, OR 97477 p: 541.746.0637 www.BranchEngineering.com
D
A Y I
SL
A N
D R
O A
D
EU
G
EN
E, O
R
EG
O N
MARCH 25, 2025
25-092
JLB
DAN
EXISTING
CONDITIONS
PRELIMINARYDIGITALLY SIGNED
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
E R
O S
IO
N
A N
D S
E D
IM
E
N T
C O
N
TR
O L
P
LA
N C
O V
E R
S H
E E
T
CONSTRUCTION SITE MANAGEMENT PLAN
ATTENTION EXCAVATORS:
RATIONALE STATEMENT
CUTHBERT AMPHITHEATER IMPROVEMENTS
Know what's below.
before you dig.Call
R
PROJECT LOCATION
PROPERTY DESCRIPTION
CIVIL ENGINEERING FIRM
APPLICANT
NARRATIVE DESCRIPTIONS
INSPECTION FREQUENCY:
GEOTECHNICAL ENGINEERING
CONTRACTOR
SITE MAP
VICINITY MAP
CONSTRUCTION SITE MANAGEMENT
PLAN NOTES:
SHEET INDEX
C050
LEGEND
G
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
P R
E -C
O N
S T
R U
C T
IO
N
C S
M P
A N
D T
R E
E R
E M
O V
A L
P L
A N
C051
MATCHLINE
SEE SHEET C052
G
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
P R
E -C
O N
S T
R U
C T
IO
N
C S
M P
A N
D T
R E
E R
E M
O V
A L
P L
A N
C052
MATCHLINE
SEE SHEET C051
G
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
P O
S T
-C O
N S
T R
U C
T
IO
N C
S M
P
C053
MATCHLINE
SEE SHEET C054
G
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
P O
S T
-C O
N S
T R
U C
T
IO
N C
S M
P
C054
MATCHLINE
SEE SHEET C053
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
C O
N S
T R
U C
T
IO
N S
IT
E
M A
N A
G E
M E
N T
D E
T A
IL
S
C055
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
C O
N S
T R
U C
T
IO
N S
IT
E
M A
N A
G E
M E
N T
D E
T A
IL
S
C056
G
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
C L
E A
R
IN
G A
N D
D E
M O
L
IT
IO
N
P L
A N
C090
MATCHLINE
SEE SHEET C091
G
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
C L
E A
R
IN
G A
N D
D E
M O
L
IT
IO
N
P L
A N
C091
MATCHLINE
SEE SHEET C090
DAY ISLAND RD
G
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
C100
P A
R K
IN
G
L O
T A
N D
E N
T R
Y P
L A
Z A
S
IT
E P
L A
N
MATCHLINE
SEE SHEET C101
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
C101
A M
P H
IT
H
E A
T H
E R
S
IT
E P
L A
N
MATCHLINE
SEE SHEET C100
SURFACING LEGEND
EN
G
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
C102
P A
R K
IN
G
L O
T A
N D
E N
T R
Y P
L A
Z A
S U
R F
A C
IN
G
P L
A N
MATCHLINE
SEE SHEET C103
SURFACING LEGEND
G
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
C103
A M
P H
IT
H
E A
T E
R S
U R
F A
C
IN
G P
L A
N
MATCHLINE
SEE SHEET C102
RELOCATED PRE'S TRAIL
EN
G
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
P A
R K
IN
G
L O
T A
N D
E N
T R
Y P
L A
Z A
G R
A D
IN
G
P L
A N
C200
LEGEND
MATCHLINE
SEE SHEET C201
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
A M
P H
IT
H
E A
T E
R G
R A
D
IN
G P
L A
N
C201
LEGEND
MATCHLINE
SEE SHEET C200
RELOCATED PRE'S TRAIL
A
A'
EN
G
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
S T
O R
M W
A T
E R
P L
A N
C202
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
U T
IL
IT
Y P
L A
N
C300
MATCHLINE
SEE SHEET C301
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
U T
IL
IT
Y P
L A
N
C301
PLANT KEY
EN
G
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
L100
L A
N D
S C
A P
E P
L A
N T
IN
G
P L
A N
A N
D N
O T
E S
GENERAL LANDSCAPE CONSTRUCTION NOTES
License Expires 5/31/27
MULTICORELINK:12082 landscape-L101
PLANT SCHEDULE
G
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
L101
L A
N D
S C
A P
E P
L A
N T
IN
G
P L
A N
A N
D S
C H
E D
U L
E
License Expires 5/31/27
MULTICORELINK:12082 landscape-L100 MULTICORELINK:12082 landscape-L102
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
L102
L A
N D
S C
A P
E P
L A
N T
IN
G
P L
A N
NOTE:
MULTICORELINK:12082 landscape-L101
DETENTION POND PLANT SCHEDULE
G
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
L103
D E
T E
N T
IO
N
P O
N D
P L
A N
T
IN
G P
L A
N
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
L104
P L
A N
T
IN
G D
E T
A
IL
S
SCALE: NTS
TYPICAL CONTAINER SHRUB PLANTING DETAIL
CUTHBERT
AMPHITHEATER
C C
1 31.8 112�
227.2 112�
C
IRRIGATION SCHEDULE
EN
G
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
L200
IR
R
IG
A
T
IO
N P
L A
N
IRRIGATION SYSTEM LAYOUT
IRRIGATION NOTES
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
L201
IR
R
IG
A
T
IO
N D
E T
A
IL
S
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
G E
N E
R A
L C
O N
S T
R U
C T
IO
N
D E
T A
IL
S
C400
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
G E
N E
R A
L C
O N
S T
R U
C T
IO
N
D E
T A
IL
S
C401
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
G E
N E
R A
L C
O N
S T
R U
C T
IO
N
D E
T A
IL
S
C402
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
G E
N E
R A
L C
O N
S T
R U
C T
IO
N
D E
T A
IL
S
C403
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
G E
N E
R A
L C
O N
S T
R U
C T
IO
N
D E
T A
IL
S
C404
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
G E
N E
R A
L C
O N
S T
R U
C T
IO
N
D E
T A
IL
S
C405
NTS
6'-0"
SLOPE 5%
SECTION
ADJACENT
CONCRETE
WALK
TOP OF RAMP. BROOM FINISH
PERPENDICULAR TO SLOPE OF RAMP.
TOP OF WOOD
CHIP SURFACING.
5-1/2"
TYP.
2" DEPTH OF 3/4" MINUS CRUSHED ROCK
LEVELING COURSE COMPACTED TO 95%, TYP.
EXISTING SUBGRADE,
COMPACT TO 95%, TYP.
GEOTEXTILE FABRIC,
EXTEND 6" BELOW RAMP.
1/2" RADIUS.
6" DEPTH, 1" MINUS CRUSHED
ROCK, COMPACT TO 95%.
3" DEPTH BARK-O-MULCH
SURFACING.
IF RAMP IS INSTALLED IN SEPARATE
POUR FROM ADJACENT PAVING,
INSTALL 1/2" X 12" DOWELS @ 18" O.C.
ALONG EDGE OF ADJACENT
CONCRETE WALK. EMBED 6" INTO
CONCRETE BOTH SIDES, TYP.
TRANSITION BASE ROCK
ELEVATION FROM ABOVE
GRADE (SEE MULCH TRAIL
CROSS-SECTION) TO BELOW
GRADE TO MATCH CONCRETE
ELEVATION. MIN. DISTANCE
OF 10' FOR APPROX. 5%
SLOPE.
CONCRETE TRANSITION RAMP AT MULCH TRAIL
EN
G
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
G E
N E
R A
L C
O N
S T
R U
C T
IO
N
D E
T A
IL
S
C406
OVERALL LENGTHOPENING COUNTERBALANCE
OUTSIDE FACE OF
POST TO OUTSIDE
FACE OF POST
OUTSIDE OF FRAME
TO OUTSIDE OF
FRAME
INSIDE FACE OF
POST TO INSIDE
FACE OF POST
EN
G
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
G E
N E
R A
L C
O N
S T
R U
C T
IO
N
D E
T A
IL
S
C407
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
Salem 503-584-1576 www.landisconsulting.com
PDERETSIGER LA
NO
ISSEFOR
OREGON
86683
NIGN
E R
EE
8 , 2
M
AY
PERR
Y
BENJAMIN
E.
EXPIRES: 12-31-2026
Digitally Signed
E L
E C
T R
IC
A
L A
B B
R E
V
IA
T
IO
N S
E001
Electrical Abbreviations, General Notes, & Symbol Legend Abbreviations
A AMPERE
AC ALTERNATING CURRENT, AIR CONDITIONING UNIT
AHJ AUTHORITY HAVING JURISDICTION
AI ANALOG INPUT
AIC AVAILABLE INTERRUPTING CAPACITY
AF AMPERE FRAME / AMPERE FUSED
AFC ABOVE FINISHED CEILING
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AL ALUMINUM
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
AO ANALOG OUTPUT
ARMS ARC FLASH REDUCTION MAINTENANCE SYSTEM
AT AMPERE TRIP
AV AUDIO / VIDEO
AWG AMERICAN WIRE GAUGE
BAS BUILDING AUTOMATION SYSTEM
BFG BELOW FINISHED GRADE
BLDG BUILDING
C CONDUIT
CAT# CATEGORY #
CB CIRCUIT BREAKER
CFM CUBIC FEET PET MINUTE
CFCI CONTRACTOR FURNISHED, CONTRACTOR INSTALLED
CFOI CONTRACTOR FURNISHED, OWNER INSTALLED
CKT CIRCUIT
CP CONTROL PANEL
CPT CONTROL POWER TRANSFORMER
CR CONTROL RELAY
CSC CONTRACTOR SUPPLIED CABLE
CU COPPER
dB DECIBEL
DC DIRECT CURRENT
DI DIGITAL INPUT
DIM DIMENSION
DIV DIVISION
DO DIGITAL OUTPUT
DTL DETAIL
DWG DRAWING
E/IP ETHERNET IP
EF EXHAUST FAN
EL ELEVATION
EMT ELECTRICAL METALLIC TUBING
EOLR END OF LINE RESISTOR
FACP FIRE ALARM CONTROL PANEL
FE FLOWMETER ELEMENT
FF FINISH FLOOR
FIT FLOWMETER TRANSMITTER
FLA FULL LOAD AMPERES
FT FOOT, FEET
FBO FURNISHED BY OTHERS
G, GND GROUND
GFCI GROUND FAULT CIRCUIT INTERRUPTER
HH HAND HOLE
HP HORSEPOWER
HRG HIGH RESISTANCE GROUND
H2S HYDROGEN SULFIDE
ID IDENTIFICATION
IDC INITIATING DEVICE CIRCUIT
IDF INTERMEDIATE DISTRIBUTION FRAME
IEEE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS
IG ISOLATED GROUND
IT INFORMATION TECHNOLOGY
I/O INPUT / OUTPUT
JB JUNCTION BOX
KAIC THOUSAND AMPS INTERRUPTING CURRENT
KCMIL THOUSAND CIRCULAR MILS
KVA KILOVOLT-AMPERE
KW KILOWATT
LAN LOCAL AREA NETWORK
LCP LOCAL CONTROL PANEL
LCS LOCAL CONTROL STATION
LED LIGHT EMITTING DIODE
LEL LOWER EXPLOSIVE LEVEL
LRG LOW RESISTANCE GROUND
LS LIMIT SWITCH
LSI ELECTRONIC TRIP UNIT ADJUSTABLE LONG TIME DELAY, SHORT TIME
DELAY, INSTANTANEOUS TRIP
LSIG ELECTRONIC TRIP UNIT WITH ADJUSTABLE LONG TIME DELAY, SHORT TIME
DELAY, INSTANTANEOUS TRIP, AND GROUND FAULT
LV LOW VOLTAGE
MCA MINIMUM CIRCUIT AMPACITY
MCC MOTOR CONTROL CENTER
MCP MOTOR CIRCUIT PROTECTOR
MDF MAIN DISTRIBUTION FRAME
MHz MEGAHERTZ
MISC MISCELLANEOUS
MLO MAIN LUGS ONLY
MOCP MAXIMUM OVERCURRENT PROTECTION
MSC MANUFACTURER SUPPLIED CABLE
MV MEDIUM VOLTAGE
MVA MEGAVOLT AMPERES
MW MEGAWATT
N NEUTRAL
NAC NOTIFICATION APPLIANCE CIRCUIT
N/A NOT APPLICABLE
NC NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
NEX REPLACE EXISTING WIRING DEVICE AND FACEPLATE WITH NEW.
BACK BOX AND CONDUIT SHALL REMAIN.
NL NIGHT LIGHT
NO NORMALLY OPEN
NTS NOT TO SCALE
OC ON CENTER
OFCI OWNER FURNISHED, CONTRACTOR INSTALLED
OFOI OWNER FURNISHED, OWNER INSTALLED
Ø PHASE
PB PULL BOX, PANIC BUTTON, PUSH BUTTON
PCP PUMP CONTROL PANEL
PDP PUMP DISCONNECT PANEL
PE PHOTO EYE
PLC PROGRAMMABLE LOGIC CONTROLLER
PNL PANEL
POE POWER OVER ETHERNET
PPM PARTS PER MILLION
PTZ PAN, TILT, ZOOM
RF RADIO FREQUENCY
RFI REQUEST FOR INFORMATION
SCADA SUPERVISORY CONTROL AND DATA ACQUISTION
SLC SIGNALING LINE CIRCUIT
SPD SURGE PROTECTION DEVICE
STD STANDARD
SW SWITCH
SWBD SWITCHBOARD
SWGR SWITCHGEAR
T/M THERMAL MAGNETIC CIRCUIT BREAKER
TBD TO BE DETERMINED
TSP TWISTED SHIELDED PAIR
TV TELEVISION / MONITOR OUTLET
TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR
TYP TYPICAL
UH UNIT HEATER
UG UNDERGROUND
UL UNDERWRITERS LABORATORIES
UPS UNINTERRUPTIBLE POWER SUPPLY
UON UNLESS OTHERWISE NOTED
USB UNIVERSAL SERIAL BUS
V VOLTS, VOLTAGE
VA VOLT-AMPERE
VFD VARIABLE FREQUENCY DRIVE
W WATT, WIRE
WCR WITHSTAND CURRENT RATING
WAP WIRELESS ACCESS POINT
WI-FI WIRELESS FIDELITY
W/ WITH
W/O WITHOUT
XFMR TRANSFORMER
XMTR TRANSMITTER
Y WYE
1P ONE POLE
2P TWO POLE
3P THREE POLE
4P FOUR POLE
General Electrical Notes
1. ALL LIGHTING BRANCH CIRCUITS SHALL BE 2#10, 1#10G IN
3/4" CONDUIT, UON.
2. ALL 20-AMP RECEPTACLE AND HARDWIRED BRANCH
CIRCUITS SHALL BE 2#12, 1#12G IN 3/4" CONDUIT, UON.
3. ALL EXIT SIGNS SHALL BE WIRED TO THE LOCAL LIGHTING
BRANCH CIRCUIT AHEAD OF ALL SWITCHING.
4. PROVIDE 0-10V DIMMING CONDUCTORS TO ALL LUMINAIRES
WHICH ARE CONTROLLED BY 0-10V DIMMERS SHOWN ON
THE DRAWINGS.
5. ALL ELEVATION HEIGHTS SHALL BE TO CENTERLINE OF
EQUIPMENT OR DEVICE UNLESS OTHERWISE NOTED.
Annotation
CONDUIT & CONDUCTOR CALLOUT. REFER TO
CONDUIT & CONDUCTOR SCHEDULE.
KEYED NOTE CALLOUT. REFER TO
CORRESPONDING SHEET KEYNOTES.
(E) INDICATES EXISTING EQUIPMENT TO REMAIN.
(D) INDICATES EXISTING EQUIPMENT TO BE
DEMOLISHED.
(N) INDICATES NEW EQUIPMENT.
KEYED NOTE CALLOUT. REFER TO
CORRESPONDING SHEET KEYNOTES.
KEYED NOTE CALLOUT. REFER TO
CORRESPONDING SHEET KEYNOTES.
MECHANICAL EQUIPMENT CALLOUT. REFER TO
MECHANICAL EQUIPMENT CONNECTION SCHEDULE.
DETAIL CALLOUT. REFER TO DETAIL AND SHEET AS
INDICATED ON CALLOUT.
FIXTURE MOUNTING CALLOUT. HEIGHT ABOVE
FINISHED FLOOR (A.F.F.) FOR INTERIOR OR GRADE
(A.F.G.) FOR EXTERIOR
XXXXX EQUIPMENT CALLOUT. REFER TO NEMA
CONNECTION SCHEDULE.
SECTION CALLOUT. REFER TO SECTION AND SHEET
AS INDICATED ON CALLOUT.
ELEVATION CALLOUT. REFER TO ELEVATION AND
SHEET AS INDICATED ON CALLOUT.
EX.XX
(RR)/(RD) INDICATED EXISTING EQUIPMENT OR DEVICE TO BE
REMOVED AND REINSTALLED.
XX
XX
XX
XX
XX
EX.XX
XX'-XX"
XXX
ELECTRICAL SHEET INDEX
Sheet Number Sheet Title
E001 Electrical Abbreviations E002 Electrical Symbol Legend E003 Electrical Details (1 of 2) E004 Electrical Details (2 of 2) E005 Electrical One-Line Diagrams E006 Electrical Schedules E100 Electrical Demolition Site Plan E101 Electrical Proposed Site Plan (1 of 2) E102 Electrical Proposed Site Plan (2 of 2)
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
Salem 503-584-1576 www.landisconsulting.com
PDERETSIGER LA
NO
ISSEFOR
OREGON
86683
NIGN
E R
EE
8 , 2
M
AY
PERR
Y
BENJAMIN
E.
EXPIRES: 12-31-2026
Digitally Signed
E L
E C
T R
IC
A
L S
Y M
B O
L L
E G
E N
D
E002
Electrical Symbol Legend Power Distribution
DUPLEX RECEPTACLE, MOUNTED AT 18" AFF, UON.
QUADPLEX RECEPTACLE, MOUNTED AT 18" AFF,
UON.
GFCI QUADPLEX RECEPTACLE, MOUNTED AT 18"
AFF, UON.
SWITCHED DUPLEX RECEPTACLE, MOUNTED AT 18"
AFF, UON.
NEMA SPECIAL RECEPTACLE, MOUNTED AT 18" AFF,
UON. NEMA CONFIGURATION AS INDICATED.
RECEPTACLE MOUNTED ON CEILING.
TAMPER RESISTANT DUPLEX RECEPTACLE,
MOUNTED AT 18" AFF, UON.
GFCI DUPLEX RECEPTACLE, MOUNTED AT 18" AFF,
UON.
PANELBOARD SURFACE MOUNT.
PANELBOARD FLUSH MOUNT.
MAIN DISTRIBUTION PANEL.
DISCONNECT SWITCH.
FUSED DISCONNECT SWITCH.
ENCLOSED CIRCUIT BREAKER.
COMBINATION STARTER.
FLOORBOX COMBINATION POWER & DATA.
FLOORBOX POWER.
POKETHRU COMBINATION POWER & DATA.
POKETHRU POWER.
POWER/DATA POLE.
SIMPLEX RECEPTACLE, MOUNTED AT 18" AFF, UON.
UTILITY CT METER.
TAMPER RESISTANT QUADPLEX RECEPTACLE,
MOUNTED AT 18" AFF, UON.
CENTER HATCHED RECEPTACLE TO BE WIRED TO
EMERGENCY CIRCUIT.
RECEPTACLE MOUNTED IN-COUNTER.
UTILITY TRANSFORMER.
Drawing Symbol Variables
3 THREE WAY SWITCH.
4 FOUR WAY SWITCH.
#J QUANTITY OF JACKS AND HORIZONTAL CABLES.
J = CAT6, JA = CAT6A, JE = CAT5E
+XX MOUNTING UNITS EXPRESSED IN INCHES TO
CENTERLINE ABOVE FINISHED FLOOR OR GRADE.
C MOUNTED HORIZONTALLY AT 4" ABOVE
COUNTERTOP.
CL CLOCK.
DR DUAL RELAY.
E RED EMERGENCY SWITCH.
EL ELEVATOR RECALL.
ETR EXISTING DEVICE SHALL REMAIN.
G GLASS BREAK SENSOR.
K KEYED SWITCH.
LF LOW FREQUENCY.
LV LOW VOLTAGE SWITCH.
M MOTOR RATED TOGGLE SWITCH.
NEX REPLACE EXISTING WIRING DEVICE AND FACEPLATE
WITH NEW. BACK BOX AND CONDUIT SHALL REMAIN.
O INTEGRAL OCCUPANCY SENSOR.
P ADA PHONE, VERIFY HEIGHT WITH ARCHITECT /
OWNER.
REX REMOVE EXISTING DEVICE / EQUIPMENT.
TK MOUNTED IN TOE KICK OF CASEWORK.
TV MOUNTED ADJACENT TO TV AT 60" AFF, UON.
V VANDAL RESISTANT.
WG WIREGUARD.
WP WEATHERPROOF.
Lighting
TROFFER LUMINAIRE, SURFACE OR RECESS
MOUNTED AS INDICATED ON THE DRAWINGS.
EMERGENCY BATTERY PACK LUMINAIRE, WALL OR
CEILING MOUNTED.
LINEAR PENDANT MOUNTED LUMINAIRE.
BOLLARD LUMINAIRE.
SITE LUMINAIRE POLE MOUNTED. NUMBER OF
HEADS AS SHOWN.
TRACK LUMINAIRE.
WALL MOUNTED LUMINAIRE.
DOWNLIGHT LUMINAIRE, SURFACE, RECESS, OR
PENDANT MOUNTED AS INDICATED ON THE
DRAWINGS.
EXIT SIGN, WALL OR CEILING MOUNTED, SINGLE
FACE WITH DIRECTIONAL CHEVRONS AS INDICATED
ON DRAWINGS.
EXIT SIGN, WALL OR CEILING MOUNTED, DOUBLE
FACE WITH DIRECTIONAL CHEVRONS AS INDICATED
ON DRAWINGS.
UNDERCABINET LUMINAIRE.
LINEAR WALL MOUNTED LUMINAIRE.
SPOT LUMINAIRE.
HALF HATCHED LUMINAIRE TO BE WIRED TO
EMERGENCY CIRCUIT.
FULL HATCHED LUMINAIRE TO BE WIRED TO
NIGHTLIGHT CIRCUIT.
WALL WASH LUMINAIRE POINTED IN DIRECTION AS
SHOWN
Raceways
CONDUIT AND/OR CONDUCTORS INSTALLED ABOVE
GRADE, CONCEALED IN WALL OR CEILING SPACE.
CONDUIT TURNED DOWN.
CONDUIT AND/OR CONDUCTORS INSTALLED BELOW
GRADE, BELOW SLAB.
CONDUIT TURNED UP.
CONDUIT STUBBED AND CAPPED.
CONDUIT DIRECT CONNECTION TO EQUIPMENT.
FLEXIBLE CONNECTION TO EQUIPMENT.
CONDUIT / WIRING CONTINUATION.
HOMERUN TO PANELBOARD.
CABLE TRAY. SIZE AND TYPE AS INDICATED ON
DRAWINGS.
Low Voltage
ETHERNET OUTLET MOUNTED AT 18" AFF, UON.
COAXIAL OUTLET MOUNTED AT 18" AFF, UON.
PHONE OUTLET MOUNTED AT 18" AFF, UON.
LOW VOLTAGE OUTLET CEILING MOUNTED.
WIRELESS ACCESS POINT CEILING MOUNTED.
WIRELESS ACCESS POINT WALL MOUNTED.
FLOORBOX DATA.
POKETHRU DATA.
DIGITAL CLOCK.
IT RACK.
VERTICAL WIRE MANAGEMENT.
One-Line Diagram
TRANSFER SWITCH, WITH FUSES OR BREAKERS AS
SHOWN ON DRAWINGS.
E
L
N
CIRCUIT BREAKER.
DRAWOUT CIRCUIT BREAKER.
ENCLOSED CIRCUIT BREAKER.
MOTOR STARTER CONTACT.
M CURRENT TRANSFORMER METER.
HTR
RA
BATT
HEATER.
REMOTE ANNUNCIATOR.
BATTERY CHARGER.
DISCONNECT SWITCH.
ENCLOSED DISCONNECT SWITCH.
FUSED DISCONNECT SWITCH.
ENCLOSED FUSED DISCONNECT SWITCH.
FUSE, RATING AS SHOWN ON DRAWINGS.
GENERATOR, CONFIGURATION AS INDICATED ON
DRAWING.
GROUND ROD.
EQUIPMENT GROUND.
MOTOR, RATED AS INDICATED ON DRAWINGS.
NEMA CONNECTION.
NAME
PANEL.
MINI POWER CENTER.NAME
SHUNT TRIP.
SURGE PROTECTION DEVICE.
DIGITAL METER.
TRANSFORMER.
VARIABLE FREQUENCY DRIVE.
SOFT STARTER.
VFD
SS
ST
SPD
DM
K KIRK KEY.
Miscellaneous
JUNCTION BOX (ROUND, SQUARE).
THERMOSTAT.
RELAY.
CORD REEL.
MOTOR / EXHAUST FAN.
CEILING FAN.
UTILITY POLE.
WEATHERHEAD.
GROUND ROD.
GROUND ROD WITH TEST WELL.
SURFACE RACEWAY / WIREMOLD.
FIRE RATED BACKBOARD.
JJ
T
R
GROUND BUS BAR.
POWER PEDESTALP
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
Salem 503-584-1576 www.landisconsulting.com
PDERETSIGER LA
NO
ISSEFOR
OREGON
86683
NIGN
E R
EE
8 , 2
M
AY
PERR
Y
BENJAMIN
E.
EXPIRES: 12-31-2026
Digitally Signed
E L
E C
T R
IC
A
L D
E T
A
IL
S (1
O F
E003
6. PROVIDE JUNCTION BOXES WITH LOCKABLE VANDAL
& TAMPER RESISTANT ENCLOSURE COVERS
(LOCKJAW). PROVIDE SIPRA ELJ 1118QH-CM, OR
APPROVED EQUIVALENT.
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
Salem 503-584-1576 www.landisconsulting.com
PDERETSI
GER LA
NO
ISSEFOR
OREGON
86683
NIG
N
E R
EE
8 , 2
M
AY
PERR
Y
BENJAMIN
E.
EXPIRES: 12-31-2026
Digitally Signed
E L
E C
T R
IC
A
L D
E T
A
IL
S (2
O F
E004
DIRECT BURY POLE
FOUNDATION (FOR
TRAIL POLES ONLY)
412DETAIL NO.NTSSCALE:
EXISTING
EARTH
3/4" MINUS
GRAVEL
COMPACTED 1/4"
CRUSHED
AGGREGATE
AROUND POLE
POLYETHYLENE
SLEEVE (ADS).
SIZE PER
MANUFACTURER.
(TYPE 10"-18")
1' -0
4' -0
2'-0"
2" DIA. WIRE ACCESS HOLE
TERMINATE CONDUIT TO
ACCESS HOLE
FINISHED GRADE
(1) 1/2"
CONDUIT MIN.
NOTES:
1. THIS DETAIL IS ONLY FOR THE PRE'S TRAIL POLES AS SHOWN ON
THE SITE PLAN. COORDINATE WITH OWNER FINAL LOCATION OF
POLES.
TYPICAL BUS POWER
PEDESTAL DETAIL
413DETAIL NO.NTSSCALE:
NOTES:
1. THIS DETAIL APPLIES TO THE BUS POWER PEDESTALS.
2. LOCATE PEDESTALS WHERE SHOWN ON THE DRAWINGS.
COORDINATE FINAL LOCATION WITH THE OWNER PRIOR TO
INSTALLATION.
3. CONTRACTOR SHALL MEET MINIMUM LOCATION AND CLEARANCE
REQUIREMENTS OF NEC ARTICLE 551.77(A).
4. TERMINATE EQUIPMENT GROUNDING CONDUCTOR (EGS) AT
EACH PEDESTAL.
5. PROVIDE CONDUIT BUSHING OR BELL FITTING AT END OF
CONDUIT.
2' -0
"SEE CONDUIT
SCHEDULES FOR SIZE.
GRAVEL, PER CIVIL.
BELL FITTING
TT-30R 30AMP
RECEPTACLE
14-50R 50AMP
RECEPTACLE
BREAKER LOCATION
LIGHT LOCATION
POWER PEDESTAL BASIS
OF DESIGN: MIDWEST
ELECTRIC, OR EQUAL.
FINISHED
GRADE
# 4 HOOPS AT 12" O.C.
8 - # 5 EQUALLY SPACED
UNDISTURBED EARTH
6' -6
INSTALL POLE WITH
ANCHORS AND LEVELING
NUTS PROVIDED BY POLE
MANUFACTURER.
PROVIDE 1" CHAMFER
AT TOP OF
CONCRETE BASE INSTALL BASE PER DETAIL
TM631.
ROADWAY POLE
MOUNTED
LIGHTING BASE
102DETAIL NO.NTSSCALE:
PROVIDE ANCHOR RODS
PER DETAIL TM. 631
NOTES:
1. PROVIDE LIGHT POLE BASE FOR POLES IN THE ROADWAY OR
PARKING LOT AS CALLED OUT ON THE SITE PLAN.
2. INSTALL THE POLE BASE PER DETAIL TM631.
PROVIDE ROUND LIGHT POLE BASE,
WIDTH AS SHOWN ON TM631.
TYPICAL FOOD CART
POWER PEDESTAL
DETAIL
414DETAIL NO.NTSSCALE:
NOTES:
1. THIS DETAIL APPLIES TO THE FOOD CART PEDESTALS.
2. LOCATE PEDESTALS WHERE SHOWN ON THE DRAWINGS.
COORDINATE FINAL LOCATION WITH THE OWNER PRIOR TO
INSTALLATION.
4. TERMINATE EQUIPMENT GROUNDING CONDUCTOR (EGS) AT
EACH PEDESTAL.
5. PROVIDE CONDUIT BUSHING OR BELL FITTING AT END OF
CONDUIT.
2' -0
"SEE CONDUIT
SCHEDULES FOR SIZE.
GRAVEL, PER CIVIL.
BELL FITTING
CS6369 50AMP
RECEPTACLE
BREAKER LOCATION
LIGHT LOCATION
POWER PEDESTAL BASIS
OF DESIGN: MIDWEST
ELECTRIC OR EQUAL.
SERVICE CABINET PEDESTAL
GROUND BUS
NEUTRAL BUS
BONDING JUMPER IN
SERVICE CABINET (1 - #1/0)
PROVIDE TWO 5/8"
GROUND RODS,
6-FT MIN. APART
#6
EN
G
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
Salem 503-584-1576 www.landisconsulting.com
PDERETSIGER LA
NO
ISSEFOR
OREGON
86683
NIGN
E R
EE
8 , 2
M
AY
PERR
Y
BENJAMIN
E.
EXPIRES: 12-31-2026
Digitally Signed
E L
E C
T R
IC
A
L O
N E
-L
IN
E D
IA
G
R A
M S
E005
(N) SERVICE CABINET PEDESTAL
120/240V, 1Ø, 400-AMP, 3-WIRE + GROUND, 22KAIC, SERVICE ENTRANCE RATED, NEMA 3R
M
UTILITY
METER
50A 2P
NEW PARKING LOT
NORTH LUMINAIRES
EXISTING EWEB
SERVICE
NEW POLE MOUNTED
TRANSFORMER
P101
P111
SCALE:
BASE MOUNTED SERVICE CABINET WITH METER3 NTSSCALE:
SERVICE PEDESTAL WIRING DETAIL2 NTS
TO
PHOTOELECTRIC
RELAY ON SERVICE
PEDESTAL
(3 - NO. 12 AWG)
50A BUS POWER PEDESTAL
CIRCUIT BREAKER (SEE DETAIL 1
ON THIS SHEET FOR QUANTITY)
120/240 VOLT
POWER SOURCE
N L2 L1
METER
PARKING LOT
ILLUMINATION CIRCUIT
H A N
SERVICE CABINET
SCALE:
ELECTRICAL ONE-LINE DIAGRAM1 NTS
400A
SHEET KEY NOTES
1. GFCI TYPE CIRCUIT BREAKER.
2. INSTALL GROUNDING PER DETAIL 4
ON THIS DRAWING.
3. PROVIDE FULLY PROVISIONED SPACE
FOR A MINIMUM OF SIX (6) ADDITIONAL
20/2 BREAKERS.
4. SEE SERVICE LOAD CALCULATIONS
ON E006.
5. PROVIDE CABINET WITH INTERIOR
LIGHT WITH SWITCH.
6. PROVIDE PHOTOCELL MOUNTED ON
TOP OF THE ENCLOSURE.
LIGHT
W/ SW
120V 20A
GFI
50A FOOD CART POWER PEDESTAL
CIRCUIT BREAKER (SEE DETAIL 1
ON THIS SHEET FOR QUANTITY)
BUS POWER
PEDESTAL #2
P103
BUS POWER
PEDESTAL #1
P102
50A 2P
20A 2P
BUS POWER
PEDESTAL #3
P104
50A 2P
BUS POWER
PEDESTAL #4
P105
50A 2P
BUS POWER
PEDESTAL #5
P106
50A 2P
FOOD CART
POWER
PEDESTAL #1
P107
50A 2P
FOOD CART
POWER
PEDESTAL #2
P108
50A 2P
FOOD CART
POWER
PEDESTAL #3
P109
50A 2P
SPACE
NEW FOOD CART
LUMINAIRES
P113
20A 2P
NEW PARKING LOT
SOUTH LUMINAIRES
P112
20A 2P
FOOD CART
POWER
PEDESTAL #4
P110
50A 2P
SCALE:
GROUNDING DETAIL4 NTS
1 1 1 1
AVAILABLE IN-RUSH
CURRENT AT THE
METER: 12,648-AMPS
CIRCUIT BREAKER
(20A, 120V, 1-P)
CIRCUIT BREAKER
TEST SWITCH
(15A, 120V, 1-P)
MAIN BREAKER
(400A, 240V, 2-P)
LIGHTING CONTACTOR
(20A, 240V COIL, 6-P)
(SEE DETAIL 1 ON THIS SHEET FOR QUANTITY)
C C
UTILITY
SECTION
CUSTOMER
SECTION
UTILITY CT METER
NEMA 3R PAINTED
STEEL ENCLOSURE
FRONT VIEW RIGHT SIDE
BACK VIEW
(INTERIOR)
LEFT SIDE
TOP VIEW
HINGED EXTERIOR DOOR WITH
DOOR STOP TO HOLD DOOR
IN OPEN POSITION
PADLOCKABLE L-HANDLE
WITH 3-POINT LATCH
UTILITY
SECTION
BREAKER
SECTION
UTILITY
SECTION
CUSTOMER
SECTION
CONDUIT SERVICE
(2) 3.0 INCH
LOAD CONDUIT(S), TYP.
UTILITY CT METER
LANDING LUGS
(#6-250MCM AL/CU)
UTILITY SIDE
GROUND LUG
CT METER
WIRING
CUTOUT
UTILITY CT METER SOCKET
AND TEST SWITCH COMBO
ENCLOSURE.
DOUBLE BARRIER
SEPARATING UTILITY
SECTION AND CUSTOMER
SECTION
TYPE JB1 JUNCTION BOX FOR
SERVICE GROUND ONLY.
SEE TM472 FOR INSTALLATION
DETAILS.
ANCHOR RODS: 3/4" X 18" X 4"
(ASTM F 1554 GRADE 36)
CONDUIT (SEE TM471 FOR DETAILS,
SEE PLANS FOR QUANTITY AND SIZE)
INSTALL 30 LB. BUILDING PAPER
1 1/2" CONDUIT FOR
GROUNDING ELECTRODE
CONDUCTOR ONLY.
GROUND ROD
GROUND ROD
1/
2"3"
6' - 0" MIN.
BASE MOUNTED SERVICE
CABINET FOUNDATION
46" 29.5"
50"
CONCRETE PAD,
PER CIVIL.
HOUSEKEEPING PAD
WITH 2" REVEAL
CONCRETE PAD,
PER CIVIL.
1/
2"
120V, 20A
GFCI RECEPTACLE
20A 2P
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
Salem 503-584-1576 www.landisconsulting.com
PDERETSI
GER LA
NO
ISSEFOR
OREGON
86683
NIGN
E R
EE
8 , 2
M
AY
PERR
Y
BENJAMIN
E.
EXPIRES: 12-31-2026
Digitally Signed
E L
E C
T R
IC
A
L S
C H
E D
U L
E S
E006
POWER CONDUIT / CONDUCTOR SCHEDULE
CONDUIT ID
NO.
CONDUIT CONDUCTORS PER CONDUIT
FROM TO DESCRIPTION NOTES
QUANTITY SIZE UNGROUNDED GROUNDED GROUNDING CABLE SPARE
P101 2 3.0 INCH - - - - - NEW POLE MOUNTED TRANSFORMER SERVICE CABINET PEDESTAL INSTALL PER ELECTRIC UTILITY (EWEB) REQUIREMENTS -
P102 1 1.0 INCH 2 - #6 - 1 - #10 - - SERVICE CABINET PEDESTAL BUS POWER PEDESTAL #1 - -
P103 1 1.0 INCH 2 - #6 - 1 - #10 - - SERVICE CABINET PEDESTAL BUS POWER PEDESTAL #2 - -
P104 1 1.0 INCH 2 - #6 - 1 - #10 - - SERVICE CABINET PEDESTAL BUS POWER PEDESTAL #3 - -
P105 1 1.0 INCH 2 - #6 - 1 - #10 - - SERVICE CABINET PEDESTAL BUS POWER PEDESTAL #4 - -
P106 1 1.0 INCH 2 - #6 - 1 - #10 - - SERVICE CABINET PEDESTAL BUS POWER PEDESTAL #5 - -
P107 1 1.25 INCH 2 - #3 1 - #3 1 - #6 - - SERVICE CABINET PEDESTAL FOOD CART POWER PEDESTAL #1 CONDUCTORS ARE OVERSIZED FOR VOLTAGE DROP -
P108 1 1.25 INCH 2 - #2 1 - #2 1 - #4 - - SERVICE CABINET PEDESTAL FOOD CART POWER PEDESTAL #2 CONDUCTORS ARE OVERSIZED FOR VOLTAGE DROP -
P109 1 1.5 INCH 2 - #1 1 - #1 1 - #4 - - SERVICE CABINET PEDESTAL FOOD CART POWER PEDESTAL #3 CONDUCTORS ARE OVERSIZED FOR VOLTAGE DROP -
P110 1 1.5 INCH 2 - #1/0 1 - #1/0 1 - #3 - - SERVICE CABINET PEDESTAL FOOD CART POWER PEDESTAL #4 CONDUCTORS ARE OVERSIZED FOR VOLTAGE DROP -
P111 1 0.75 INCH 2 - #10 - 1 - #10 - - SERVICE CABINET PEDESTAL PARKING LOT NORTH LUMINAIRES - -
P112 1 1.0 INCH 2 - #10 - 1 - #10 - - SERVICE CABINET PEDESTAL PARKING LOT SOUTH LUMINAIRES - -
P113 1 1.0 INCH 2 - #14 - 1 - #4 - - SERVICE CABINET PEDESTAL FOOD CART LUMINAIRES CONDUCTORS ARE OVERSIZED FOR VOLTAGE DROP -
P114 1 1.0 INCH - - - - - SERVICE CABINET PEDESTAL AT GRADE UTILITY BOXES PROVIDE PULL STRING. CONDUIT SHALL BE SPARE FOR FUTURE COLUMN
LIGHTING -
NOTES:
LUMINAIRE SCHEDULE
FIXTURE
NO. DESCRIPTION LAMP
TYPE
LUMENS
(MINIMUM) CRI COLOR
TEMP. DRIVER EMERGENCY
DRIVER
INTEGRAL
MOTION/PHOTO
SENSOR
VOLTS LOAD MFR. MODEL NUMBER
P14
14"W x 18.44"L POLE MOUNTED LUMINAIRE WITH ROUND DECORATIVE HEAD, DIE CAST ALUMINUM ALLOY HOUSING, IMPACT RESISTENT TEMPERED GLASS COATING, ONE-PIECE EXTRUDED VULCANIZED SILICONE GASKET, INTEGRAL 10kV SURGE SUPPRESSION, STAINLESS STEEL FASTENERS, FADE AND ABRASION RESISTANT FINISH, AND WET LOCATION LISTED. POLYCARBONATE LENS TYPE 4 WIDE DISTRIBUTION, SWEPT CASE ARM POLE MOUNTING, BLACK MATTE FINISH, SINGLE HEAD.
POLE SHALL BE 14' HIGH 4" DIAMETER x 11 GAUGE ROUND POLE CARBON STEEL, 3"X5" HANDHOLE LOCATED AT THE TOP OF THE POLE AS SHOWN ON SHEET E003, DETAIL TM629 (C), POWDERCOATED BLACK MATTE FINISH.
LED 5,150 LM 70 4000K STANDARD
0-10V NO NO UNV 42 WATTS KIM LIGHTING
FIXTURE: ERA RA SERIES
POLE: KRS SERIES
ARM: HA03S-TM1/BL
P16
14"W x 18.44"L POLE MOUNTED LUMINAIRE WITH ROUND DECORATIVE HEAD, DIE CAST ALUMINUM ALLOY HOUSING, IMPACT RESISTENT TEMPERED GLASS COATING, ONE-PIECE EXTRUDED VULCANIZED SILICONE GASKET, INTEGRAL 10kV SURGE SUPPRESSION, STAINLESS STEEL FASTENERS, FADE AND ABRASION RESISTANT FINISH AND WET LOCATION LISTED. POLYCARBONATE LENS TYPE 4 WIDE DISTRIBUTION, SWEPT CASE ARM POLE MOUNTING, BLACK MATTE FINISH, SINGLE HEAD.
POLE SHALL BE 16' HIGH 4" DIAMETER x 11 GAUGE ROUND POLE CARBON STEEL, 3"X5" HANDHOLE LOCATED AT THE TOP OF THE POLE AS SHOWN ON SHEET E003, DETAIL TM629 (C), POWDERCOATED BLACK MATTE FINISH.
LED 5,150 LM 70 4000K STANDARD
0-10V NO NO UNV 42 WATTS KIM LIGHTING
FIXTURE: ERA RA SERIES
POLE: KRS SERIES
ARM: HA03S-TM1/BL
P24
14"W x 18.44"L POLE MOUNTED LUMINAIRE WITH ROUND DECORATIVE TWIN HEAD, DIE CAST ALUMINUM ALLOY HOUSING, IMPACT RESISTENT TEMPERED GLASS COATING, ONE-PIECE EXTRUDED VULCANIZED SILICONE GASKET, INTEGRAL 10kV SURGE SUPPRESSION, STAINLESS STEEL FASTENERS, FADE AND ABRASION RESISTANT FINISH AND WET LOCATION LISTED. POLYCARBONATE LENS TYPE 4 WIDE DISTRIBUTION, SWEPT CASE ARM POLE MOUNTING, BLACK
MATTE FINISH, DUAL HEAD.
POLE SHALL BE 14' HIGH 4" DIAMETER x 11 GAUGE ROUND POLE CARBON STEEL, 3"X5" HANDHOLE LOCATED AT THE TOP OF THE POLE AS SHOWN ON SHEET E003, DETAIL TM629 (C), POWDERCOATED BLACK MATTE FINISH.
LED 5,150 LM / HEAD 70 4000K STANDARD
0-10V NO NO UNV 42 WATTS /
HEAD KIM LIGHTING
FIXTURE: ERA RA SERIES
POLE: KRS SERIES
ARM: HA03S-TM1/BL
P26
14"W x 18.44"L POLE MOUNTED LUMINAIRE WITH ROUND DECORATIVE TWIN HEAD, DIE CAST ALUMINUM ALLOY HOUSING, IMPACT RESISTENT TEMPERED GLASS COATING, ONE-PIECE EXTRUDED VULCANIZED SILICONE GASKET, INTEGRAL 10kV SURGE SUPPRESSION, STAINLESS STEEL FASTENERS, FADE AND ABRASION RESISTANT FINISH AND WET LOCATION LISTED. POLYCARBONATE LENS TYPE 4 WIDE DISTRIBUTION, SWEPT CASE ARM POLE MOUNTING, BLACK
MATTE FINISH, DUAL HEAD.
POLE SHALL BE 16' HIGH 4" DIAMETER x 11 GAUGE ROUND POLE CARBON STEEL, 3"X5" HANDHOLE LOCATED AT THE TOP OF THE POLE AS SHOWN ON SHEET E003, DETAIL TM629 (C), POWDERCOATED BLACK MATTE FINISH.
LED 5,150 LM / HEAD 70 4000K STANDARD
0-10V NO NO UNV 42 WATTS /
HEAD KIM LIGHTING
FIXTURE: ERA RA SERIES
POLE: KRS SERIES
ARM: HA03S-TM1/BL
SHEET KEY NOTES
1. LUMINAIRES SHALL BE OWNER
STANDARD, NO EQUAL.
JJJ
G
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
Salem 503-584-1576 www.landisconsulting.com
PDERETSIGER LA
NO
ISSEFOR
OREGON
86683
NIGN
E R
EE
8 , 2
M
AY
PERR
Y
BENJAMIN
E.
EXPIRES: 12-31-2026
Digitally Signed
E L
E C
T R
IC
A
L D
E M
O L
IT
IO
N S
IT
E
P L
A N
E100
30'15'0'
GENERAL SHEET NOTES
SHEET KEY NOTES
SCALE:
ELECTRICAL DEMOLITION SITE PLAN1 1" = 30'
(E) LIGHTING JUNCTION BOX
(E) 2.0 INCH CONDUIT
[2-#8, 2-#4, 4-#6]
(E) 2.0 INCH CONDUIT
[2-#6]
(E) 2.0 INCH CONDUIT
[2-#4, 2-#6]
(E) 0.75 INCH CONDUIT
[2-#12]
(E) FLOOD LIGHT TO REMAIN
EXISTING UTILITY BUILDING
CUTHBERT
AMPHITHEATER
1. EXISTING CONDITIONS ARE SHOWN
BASED ON AS-BUILTS. CONTRACTOR
SHALL FIELD VERIFY FINAL ROUTING
OF EXISTING CONDUIT & CONDUCTOR.
1. EXISTING LUMINAIRES AND POLES
SHALL BE REMOVED AND RELOCATED
AS SHOWN ON THE NEW LIGHT
FIXTURE LAYOUT.
2. DEMOLISH EXISTING CONDUIT AND
COIL CONDUCTORS BACK TO (E)
LIGHTING JUNCTION BOX. ABANDON
EXISTING CONDUITS AND INSTALL
NEW AS SHOWN ON THE NEW LIGHT
FIXTURE. REUSE THE EXISTING
CONDUCTORS AND REFEED LIGHTS IN
NEW LOCATIONS AS SHOWN ON NEW
PLAN.
J
P
P24
P16
P16 P16
P14
P16
P16 P24 P24
P24
J
J
P
P
P
P
P16 P16
P16
J
J
J
J
J
J
J
J J
J
J
EN
G
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
Salem 503-584-1576 www.landisconsulting.com
PDERETSIGER LA
NO
ISSEFOR
OREGON
86683
NIGN
E R
EE
8 , 2
M
AY
PERR
Y
BENJAMIN
E.
EXPIRES: 12-31-2026
Digitally Signed
E L
E C
T R
IC
A
L P
R O
P O
S E
D S
IT
E
P L
A N
O F
E101
SCALE:
ELECTRICAL PROPOSED SITE PLAN (1 OF 2)1 1" = 30'
30'15'0'
SHEET KEY NOTES
(E) LIGHTING JUNCTION BOX
(E) 2.0 INCH CONDUIT
[2-#8, 2-#4, 4-#6]
(E) 2.0 INCH CONDUIT
[2-#6]
(E) 2.0 INCH CONDUIT
[2-#4, 2-#6]
(E) 0.75 INCH CONDUIT
[2-#12]
(E) FLOOD LIGHT TO REMAIN
(N) 1.5 INCH CONDUIT
(E) UTILITY POLE
P101
(N) SERVICE CABINET PEDESTAL
P110
SEE SHEET E102
FOR CONTINUATION
P102
P103
P104
P105
P106
1. EXISTING LUMINAIRES AND POLES
RELOCATED INTO NEW AREA. INSTALL
DIRECT BURY POLE PER SHEET E004,
DETAIL 412.
2. PROVIDE NEW CONDUIT. PROVIDE
NEW CONDUCTORS (2 - #6, 1 - #6G) TO
RELOCATED FIXTURES.
3. COORDINATE UTILITY SERVICE
INSTALLATION WITH EWEB. PROVIDE
CONCRETE PAD PER DETAIL ON E005
4. PROVIDE POLE LIGHT PER E003,
DETAIL TM629(C).
5. PROVIDE AND INSTALL POWER
PEDESTAL AS SHOWN ON E004,
DETAIL 413.
6. PROVIDE AT-GRADE UTILITY BOXES
AND SLEEVES FOR FEEDING FUTURE
LIGHTS. PROVIDE CONCRETE
POLYMER JUNCTION BOXES PER
DRAWING E003, DETAIL TM472(A).
7. PROVIDE PARKING LOT LIGHT BASE
TO PROTECT FROM VEHICLE DAMAGE
PER DETAIL 101 PER E004.
8. CONTRACTOR SHALL COORDINATE
WITH ELECTRIC UTILITY (EWEB) FOR
INSTALLATION OF NEW SERVICE.
EWEB SHALL PROVIDE AND INSTALL
NEW UTILITY POLE & TRANSFORMER,
CONDUCTORS, AND TERMINATIONS
TO THE EQUIPMENT. CONTRACTOR
SHALL PROVIDE AND INSTALL NEW
CONDUITS AND SERVICE PEDESTAL
WITH EWEB APPROVED CT METER.
CONTRACTOR SHALL INSTALL
EQUIPMENT PER EWEB'S SERVICE
REQUIREMENTS.
9. PROVIDE JUNCTION BOX FOR
GROUND ROD AS SHOWN ON DETAIL 3
ON SHEET E005.
10. INSTALL BOLLARDS PER CIVIL.
11. DIRECTIONAL DRILL THE UTILITY
CONDUIT BELOW THE ROAD.
COORDINATE WITH OWNER PRIOR TO
BORING.
12. PROVIDE TRAFFIC-RATED IN-GROUND
BOXES PER UTILITY REQUIREMENTS.
COORDINATE WITH UTILITY (EWEB)
PRIOR TO INSTALLATION.
SEE SHEET E102
FOR CONTINUATION
P111 P111 P111
P111
P112
P112
P112
P112 P112 P112
P102
P103
P104
P105
P102
P103
P104
P102
P103
P102
(N) BUS POWER PEDESTAL #5
(N) BUS POWER PEDESTAL #1
GENERAL SHEET NOTES
1. COORDINATE FINAL LOCATION OF
POWER PEDESTALS WITH OWNER
PRIOR TO INSTALL.
2. CONTRACTOR SHALL COORDINATE
UNDERGROUND CONDUIT ROUTING
WITH LANDSCAPE IMPROVEMENTS.
ROUTE CONDUITS TO AVOID
CONFLICTS WITH EXISTING AND
PROPOSED TREES, INCLUDING ROOT
ZONES, AND MINIMIZE IMPACT TO
LANDSCAPING.
3. TRENCHING AND CONDUIT SHALL BE
INSTALLED OUTSIDE OF THE DRIP
LINE OF TREES. CONDUITS ON THIS
PLAN HAVE BEEN SHOWN TO AVOID
THE DRIP LINE. VERIFY EXACT
LOCATIONS IN FIELD WITH OWNER
AND ENGINEER PRIOR TO TRENCHING.
P114 P114
P113
P113
P113
P114
P108
P109
P107
P110
P113
P114
P108
P109
P107
P110
P113P108
P109
P107
(E) LUMINAIRE
(E) LUMINAIRE
SHEET KEY NOTES
P113
(N) BUS POWER PEDESTAL #2
(N) BUS POWER PEDESTAL #3
(N) BUS POWER PEDESTAL #4
P101
P101
(N) UTILITY IN-GROUND BOX
(N) UTILITY IN-GROUND BOX
P26
P26
P26
P
P
P26 J
J
J
J
J
J
J
J
EN
G
IN
EE
R
IN
G
SU
R
VE
YI
N
G
FO
R
ES
TR
Y
N A
TU
R
A L
R
ES
O U
R C
ES
LA
N D
SC
A
PE
A
R C
H
IT
EC
TU
R E
PL
A
N N
IN
G
C U
T H
B E
R T
A M
P H
IT
H
E A
T E
R
IM
P R
O V
E M
E N
T S
E U
G E
N E
O R
E G
O N
Salem 503-584-1576 www.landisconsulting.com
PDERETSI
GER LA
NO
ISSEFOR
OREGON
86683
NIGN
E R
EE
8 , 2
M
AY
PERR
Y
BENJAMIN
E.
EXPIRES: 12-31-2026
Digitally Signed
E102SCALE:
ELECTRICAL PROPOSED SITE PLAN (2 OF 2)1 1" = 30'
30'15'0'
EXISTING UTILITY BUILDING
CUTHBERT
AMPHITHEATER
(E) 2.0 INCH CONDUIT
[2-#8, 2-#4, 4-#6]
SEE SHEET E101
FOR CONTINUATION
SEE SHEET E101
FOR CONTINUATION
P113
P109
P108
P107
FOOD CART POWER PEDESTAL #1
FOOD CART POWER PEDESTAL #2
FOOD CART POWER PEDESTAL #3
GENERAL SHEET NOTES
SHEET KEY NOTES
1. COORDINATE FINAL LOCATION OF
POWER PEDESTALS WITH OWNER
PRIOR TO INSTALL.
2. CONTRACTOR SHALL COORDINATE
UNDERGROUND CONDUIT ROUTING
WITH LANDSCAPE IMPROVEMENTS.
ROUTE CONDUITS TO AVOID
CONFLICTS WITH EXISTING AND
PROPOSED TREES, INCLUDING ROOT
ZONES, AND MINIMIZE IMPACT TO
LANDSCAPING.
3. TRENCHING AND CONDUIT SHALL BE
INSTALLED OUTSIDE OF THE DRIP
LINE OF TREES. CONDUITS ON THIS
PLAN HAVE BEEN SHOWN TO AVOID
THE DRIP LINE. VERIFY EXACT
LOCATIONS IN FIELD WITH OWNER
AND ENGINEER PRIOR TO TRENCHING.
1. COORDINATE FINAL LOCATION OF THE
FOOD CART PEDESTALS TO BE
ADJACENT TO THE WATER
CONNECTIONS. PROVIDE AND INSTALL
POWER PEDESTAL AS SHOWN ON
E004, DETAIL 414.
2. PROVIDE AT-GRADE UTILITY BOXES
FOR SPLICING OVERSIZED
CONDUCTORS. PROVIDE CONCRETE
POLYMER JUNCTION BOXES PER
DRAWINGS E003, DETAIL TM472(A).
3. PROVIDE AT-GRADE UTILITY BOXES
AND SLEEVES FOR FEEDING FUTURE
LIGHTS. PROVIDE CONCRETE
POLYMER JUNCTION BOXES PER
DRAWING E003, DETAIL TM472(A).
P110
FOOD CART POWER PEDESTAL #4
E L
E C
T R
IC
A
L P
R O
P O
S E
D S
IT
E
P L
A N
O F
P113
P110
P113P108
P109
P107
P110
P113
P108
P109
P109
P110
P113
P110
P113
| Sheets and Views |
| C050 EROSION AND SEDIMENT CONTROL PLAN COVER SHEET |
| C053 POST-CONSTRUCTION CSMP |
| C056 CONSTRUCTION SITE MANAGEMENT DETAILS |
| C100 PARKING LOT AND ENTRY PLAZA SITE PLAN |
| C405 GENERAL CONSTRUCTION DETAILS |
| C406 GENERAL CONSTRUCTION DETAILS |
| C407 GENERAL CONSTRUCTION DETAILS |
| 2026-07-22T09:14:46-0700 | |
| Richard Walker |