2027-WCSU-ITB-002 WSCB Boiler Replacement - Dwgs.pdf

PDF 1 MB Posted

Attached to
Westside Classroom Building Boiler Replacement Project - Westside Campus
Solicitation number
2027-WCSU-ITB-002
Issued by
Fairfield County, Connecticut

About this file

This is a technical drawings document for Western Connecticut State University (WCSU) supporting an Invitation to Bid (ITB) for the replacement of an existing boiler at the Westside Classroom Building located on the Westside Campus in Danbury, Connecticut. The project encompasses all labor and materials required to complete the boiler replacement. The document provides the engineering specifications and technical plans necessary for bidders to accurately estimate project scope and costs.

The project is funded with $350,000 in state funding and is subject to Connecticut Department of Labor Prevailing Wage Rates requirements and state contract compliance regulations, including nondiscrimination statutes. The contract includes specific spending allocation goals for Small Business Enterprises (SBEs) and Minority Business Enterprises (MBEs), with an overall SBE goal of 10.45% ($36,567.00), an MBE sub-goal of 3.26% ($11,398.00), and an SBE-Only (Non-MBE) goal of 7.19% ($25,170.00). Selected contractors must demonstrate good faith effort in meeting these spending allocation goals. This project is subject to state contract compliance requirements and small business utilization targets in accordance with Connecticut state law.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DANBURY, CONNECTICUT 06810

BOILER REPLACEMENT

WESTERN CONNECTICUL STATE UNIVERSITY

CLASSROOM BUILDING

09 - 01 - 2026

M

12 25

N

O

P

Q

M

12 25

N

O

P

Q

EXIST.

BOILER

B#2

EXIST.

BOILER

B#1

EXIST.

P-4 (CHW)

EXIST.

P-3 (CHW)

Ø

20Ø 16Ø

14Ø14Ø

Ø

10Ø

EFD

EFD

EFD

60x24

60x

60x24 x2

80x36

EXISTING 8'x8'

O/A LOUVER

EXISTING 2'x5'

EXHAUST

LOUVER

EXIST. AHU-1

F.D.

24x20 24x12

EXIST. IN-LINE

SUPPLY FAN ISE-1

EXIST.

AHU-5

30x14

30x14 x1 x1

6"

CH

W

R

CH

W S

CH

W

S

6"6"

1"CHWS&R

3/4"HWR

6"CHWS

CH

W

S

4"HWS

3/4"HWS

EFD

F.D.

F.D.

5"HWS

G

G

G

1"CHWS&R

HWR

CHWR

EXIST. P-1 (HW)

EXIST. P-2 (HW)

HOT WATER COMPRESSION

TANK

CHILLED WATER

COMPRESSION

TANK

EXIST.

ROLAIRTROL

CHILLED WATER

SYSTEM MAKE -UP

WATER

DUPLEX AIR

COMPRESSOR FOR

PNEUMATIC CONTROL

EXIST.

ROLAIRTROL

ABANDONED OIL

PIPE TRENCH

DOMESTIC HOT

WATER

HEATERS (TYP.

OF TWO)

HOT WATER SYSTEM

MAKE -UP WATER

20"Ø BREECHING UP

10"Ø BREECHING UP

FUEL OIL

GAGE

2000 CFM

2000 CFM

CFM

THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING UTILITY LINES INCLUDING ELECTRICAL, SEWER, WATER, GAS, TELEPHONE, ETC. THE DRAWINGS SHOW DIAGRAMMATICALLY THE APPROXIMATE LOCATION OF UTILITIES WHERE INFORMATION IS AVAILABLE, BUT THE DRAWINGS ARE NOT EXACT AS TO THE QUANTITY, EXTENT OR LOCATION. THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION DURING ALL PHASES OF THE WORK TO LOCATE, IDENTIFY, AND PROTECT EXISTING UTILITIES. THE CONTRACTOR SHALL RECORD LOCATION OF AND REPAIR DAMAGE TO EXISTING UTILITIES WHICH ARE ENCOUNTERED AS A RESULT OF WORK

UNDER THIS CONTRACT.

ANY EQUIPMENT REMOVED DURING DEMOLITION WORK MAY BE RETAINED BY THE OWNER AT HIS OPTION. ANY SUCH MATERIAL SHALL BE STORED IN THE BUILDING AT A LOCATION DESIGNATED BY THE OWNER. REMOVAL OF SUCH MATERIAL FROM THE JOB SITE SHALL BE THE

OWNER'S RESPONSIBILITY.

REMOVE AND REPLACE ALL EXISTING PIPE INSULATION FOR ON THE SUPPLY AND RETURN HEADERS.

ALL PIPES (NEW AND EXISTING) SHALL BE LABELED. CONTRACTOR SHALL MEASURE, RECORD AND SUBMIT REPORT FOR THE EXISTING HW

PUMPS (FLOW AND PRESSURE DROP) PRIOR TO ANY DEMOLITION.

2 - THE DEMOLITION DRAWINGS ARE INTENDED ONLY TO DEFINE THE GENERAL SCOPE OF DEMOLITION WORK AND TO ASSIST THE CONTRACTOR DURING BIDDING. THE DEMOLITION DRAWINGS MAY NOT SHOW EVERY ITEM WHICH MUST BE DISCONNECTED, REMOVED, OR RELOCATED IN ORDER TO FACILITATE NEW WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION

WORK REQUIRED WHETHER OR NOT SHOWN ON THE PLANS.

1 - PRIOR TO SUBMITTING BID, VISIT THE SITE AND IDENTIFY EXISTING CONDITIONS AND DIFFICULTIES THAT WILL AFFECT WORK TO BE PERFORMED. NO COMPENSATION WILL BE GRANTED FOR ADDITIONAL WORK CAUSED BY UNFAMILIARITY WITH SITE CONDITIONS THAT ARE VISIBLE OR READILY CONSTRUED BY EXPERIENCED OBSERVERS. INCLUDE IN THE BID ALL DEMOLITION WORK REQUIRED.

3 - COORDINATE AND SCHEDULE ALL WORK WITH THE OWNER TO MINIMIZE INCONVENIENCE TO THE BUILDING OCCUPANTS. ALL SERVICES AND SYSTEMS SERVING OCCUPIED AREAS OF THE BUILDING SHALL BE MAINTAINED IN OPERATION DURING WORKING SHIFTS.

4 - CONTRACTOR IS RESPONSIBLE FOR ANY TEMPORARY WORK REQUIRED TO KEEP THE BUILDING OCCUPIED DURING CONSTRUCTION.

5 - REMOVE AND/OR RELOCATE ALL EXISTING MECHANICAL WORK AS NECESSARY FOR THE PERFORMANCE OF THE WORK OF THIS

CONTRACT.

6 - REMOVE ALL DEMOLITION MATERIAL FROM THE JOB SITE UNLESS NOTED DIFFERENTLY.

7 - CONTRACTOR SHALL FIELD VERIFY LOCATION AND SIZE OF ALL EXISTING PIPING IN THE BOILER ROOM PRIOR TO ANY DEMOLITION.

8 - CONTRACTOR SHALL MEASURE AND RECORD EXISTING HW FLOWS PRIIOR TO ANY DEMOLITION. WHEN STARTING THE NEW BOILERS, CONTRACTOR SHALL RESTORE THE HW FLOWS TO THE RECORDED VALUES REPLACE EXISTING PIPE INSULATION ON THE MAIN

SUPPLY AND RETURN HEADER FROM THE BOILER TO THE AIR SEPARATOR. .

TAG ACTION

EXISTING HEATING BOILER AND ASSOCIATED PIPES, VALVES & ACCESSORIES SHALL BE REMOVED. CAP REMAINING OIL PIPE, HOT WATER SUPPLY & RETURN PIPING FOR FUTURE CONNECTION. EXISTING BOILER CONCRETE PAD SHALL REMAIN.

REPLACE BOILER IN KIND.

EXISTING AIR SEPARATOR AND ASSOCIATED PIPING SHALL REMAIN

EXISTING COLD WATER MAKE-UP PIPE SHALL REMAIN

EXISTING BOILER CONTROLS AND ASSOCIATED ACCESSORIES SHALL REMAIN. CONNECT NEW BOILER CONTOLS TO EXISTING.

EXISTING PUMPS SHALL REMAIN. UPGRADE CONTROLS.

EXISTING COMBUSTION AIR LOUVER AND DUCT SHALL REMAIN.

EXISTING GAS PIPE SHALL BE REMOVED. CAP REMAINING FOR FUTURE CONNECTION.

EXISTING BOILER FLUE EXHAUST SHALL BE REMOVED. TEMPORARILY CAP OPENING FOR FUTURE CONNECTION. EXISTING

BREACHING SHALL REMAIN

EXISTING COMPRESSION TANK AND ASSOCIATED PIPING SHALL REMAIN

EXISTING FLOOR DRAINEFD

RISE OR DROP

RISER DOWN

BRANCH-TOP CONNECTION

RISER UP

SHUTOFF VALVE

COLD WATER

EXISTING CHILLED WATER SUPPLY

HOT WATER RECIRCULATINGCHWR

CHWS

CW

HOT WATER HEATING SUPPLY

HOT WATER HEATING RETURNHWR

HWS

GAS SHUTOFF VALVE

POINT OF CONNECTIONPOC

G GAS PIPEG

OF ALL SYSTEMS TO AVOID CONFLICTS.

THE CONTRACTOR SHALL COORDINATE THE ROUTING AND INSTALLATION

DRAWINGS ARE DIAGRAMMATIC AND SHOW GENERAL INTENT OF WORK,

ALL CONTRACTORS MUST COORDINATE WITH OTHER TRADES OTHER

TRADES BEFORE PROCEEDING WITH ANY WORK.

2.

1.

THE EXISTING CONDITIONS PRIOR TO SUBMITTING HIS BID.

THE CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH3.

REQUIRED TO KEEP THE BUILDING OCCUPIED DURING THE CONSTRUCTION.

8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY TEMPORARY WORK

7. BRANCH TAKE-OFFS FOR FLUE AND COMBUSTION AIR SHALL BE

5. INSTALL PIPES TO ALLOW EASY ACCESS TO VALVES.

AT 45° ANGLES.

6. INSULATE ALL HOT WATER HEATING SUPPLY AND RETURN PIPING.

AND SIZES.

THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING PIPE LOCATIONS4.

EXIST.

BOILER

B#2

NEW

BOILER

B#1

EXIST.

P-4 (CHW)

EXIST.

P-3 (CHW)

Ø

20Ø 16Ø

14Ø

Ø

10Ø

EFD

EFD

EFD

60x24

60x

60x24 x2

80x36

EXISTING 8'x8'

O/A LOUVER

EXISTING 2'x5'

EXHAUST

LOUVER

EXIST. AHU-1

F.D.

24x20 24x12

EXIST. IN-LINE

SUPPLY FAN ISE-1

EXIST.

AHU-5

30x14

30x14 x1 x1

6"

CH

W

R

CH

W S

CH

W

S

6"6"

1"CHWS&R

3/4"HWR

6"CHWS

CH

W

S

4"HWS

3/4"HWS

EFD

F.D.

F.D.

5"HWS

1"CHWS&R

HWR

CHWR

EXIST. P-1 (HW)

EXIST. P-2 (HW)

HOT WATER COMPRESSION

TANK

CHILLED WATER

COMPRESSION

TANK

EXIST.

ROLAIRTROL

CHILLED WATER

SYSTEM MAKE -UP

WATER

DUPLEX AIR

COMPRESSOR FOR

PNEUMATIC CONTROL

EXIST.

ROLAIRTROL

ABANDONED OIL

PIPE TRENCH

DOMESTIC HOT

WATER

HEATERS (TYP.

OF TWO)

HOT WATER SYSTEM

MAKE -UP WATER

20"Ø BREECHING UP

10"Ø BREECHING UP

FUEL OIL

GAGE

2000 CFM

2000 CFM

CFM

CONCRETE

PAD (TYP.)

2. DISCONNECT, MOTOR STARTERS AND CONTROLS BY DIVISION 23

3. BOILER MANUFACTURER SHALL PROVIDE BACNET COMPATIBLE BOILER CONTROLS

1. POWER WIRING AND RACEWAY BY DIVISION 26. COORDINATE WITH ELECTRICAL CONTRACTOR

LOCATION

REMARKS:

TAG

B-1

MANUF. MODEL

Burner Capacity

REMARKS

59 1985RTS 28HE-8 SERIES

HIGH EFFICIENCY WATER BOILER

BOILER

HORSE-POWER

4. TIE BOILER CONTROLS INTO LOCAL BMS

MECHANICAL ROOM

CLASSROOM BUILDING

SMITH

CAST IRON BOILERS

GROSS

OUTPUT

(MBH) OIL

GPH

GAS

MBH

Heating Surface (Sq.Ft)

177.6

Furnace Volume (Cu.Ft)

28.44

Thermal Efficiency

OIL GAS

82.6 -

Combustion Efficiency

OIL GAS

83.5

Dia. Vent Conn.

12"

Burner - Gas/Oil

Burner Operation: Low -High--Low Model No.

C2-G-20A

H.P.

3/4

Power Flame

5"HWR

FOR BOILERS PIPING LAYOUT

SEE SCHEMATIC PIPING

DIAGRAM ON M1.2 DWG

THE CONTRACTOR SHALL

FIELD VERIFY ALL EXISTING PIPE

LOCATIONS AND SIZES.

Pump

LOCATION MODELAREA SERVED TYPE MANUFACTURER SERIES GPM PHVOLTS REMARKSHP

REMARKS:

1. UNIT SHALL BE SEISMICALLY SUPPORTED.

2. INSTALL ACCORDING TO MANUFACTURER'S RECOMMENDATIONS.

3. OPERATING

HEAD

(FT) MODEL

SUCTION DIFFUSER

SYS. SIDE SUCT. SIDE

Pump PLEVv

EFFICIENCY

Control

HEAD

(FT)

BP-1 BELL & GOSSETT 1,2,3,4,5- --MECHANICAL RM BOILER CIRC. PUMP CIRCULATING IN LINE 80 289212 12080.520-140 -3.6

RPM @

Duty point

Motor Speed

(RPM)

4. POWER WIRING AND RACEWAY BY DIVISION 26. COORDINATE WITH THE ELECTRICAL CONTRACTOR.

5. DISCONNECTS AND STARTING RELAYS FURNISHED BY DIVISION 23.

No.

Ecocirc XL 20-140

ALTERNATE#1

G

G

G

CONNECT NEW 12"dia BOILER VENT

TO EXISTING IN THIS AREA

CONNECT NEW 3"GAS PIPE TO

EXISTING IN THIS AREA. CONTRACTOR

SHALL FIELD VERIFY EXACT LOCATION

5. THIS CONTRACTOR SHALL PROVIDE THE GAS TRAIN FOR THE NEW BURNER, INCLUDING ISOLATION VALVES AND VENTLESS REGULATOR

VOLTS

PH

1 1,2,3,4,5

BP-2 BELL & GOSSETT 1,2,3,4,5- --MECHANICAL RM BOILER CIRC. PUMP CIRCULATING IN LINE 80 289212 12080.520-140 -3.6 -Ecocirc XL 20-140

M1.1

MECHANICAL RM.

PART PLAN

MECHANICAL

DEMOLITION &

NEW WORK

C O

PY

R

IG

H

T C

Th is d ra w in g is a n in st ru m en t o f s er vi ce a nd sh al l r em ai n th e pr op er ty of B em is

A ss oc ia te s L

LC

, w he th er th e pr oj ec t f or w hi ch it is in te nd ed is c on st ru ct ed o r n ot

Th is d ra w in g, a nd th e co nc ep ts a nd id ea s co nt ai ne d he re in

, s ha ll no t b e us ed

, c op ie d or re ta in ed w ith ou t t he ex pr es s w rit te n ap pr ov al o f B em is

A ss oc ia te s L

LC

Su bm is si on o r d is tri bu tio n of th is d ra w in g to m ee t o ff ic ia l r eg ul at or y re qu ire m en ts o r f or o th er p ur po se s i n co nn ec tio n w ith th e pr oj ec t i s n ot to b e co ns tru ed a s p ub lic at io n in d er og at io n of a ny o f t he ri gh ts o f

B em is A ss oc ia te s L

LC

A ny a br id ge m en t o r v io la tio n of th e rig ht s o f B em is A ss oc ia te s L

LC

sh al l b e pr os ec ut ed to th e fu lle st e xt en t p os si bl e un de r t he la w

D A

N B

U R

Y C

T

B O

IL

ER

R

EP

LA

C

EM

EN

T W

C

SU

C

LA

SS

R O

O M

B U

IL

D

IN

G

09-01-2026

PRV-1

EXISTING

PRESSURE REDUCING VALVE

P-1 P-2

EXISTING

DIFFERENTIAL PRESSURE

SENSOR CONTROLLER

DP

BP-1

NEW

BOILER

B#1

EXISTING

BOILER

B#2

EXISTING

ROLAIRTROL

EXISTING

COMPRESSION TANK

EXISTING

MODULATING VALVE

BURNERBURNER

HOUSEKEEPING PAD

(TYPICAL)

BP-2

ALTERNATE #1

P U

M P

R U

N S

TA

TU

S

P U

M P

E N

A B

LE

/D

IS

A

B

LE

H W

S T

E M

P

H W

R T

E M

P

H W

S T

E M

P

P U

M P

E N

A B

LE

/D

IS

A

B

LE

P U

M P

R U

N S

TA

TU

S

B O

IL

E

R R

E S

E T

TE

M

P

B O

IL

E

R S

TA

R

T / S

TO

P

HWR

HWR

HWS

HWS

HWS

RUN CONDITIONS: THE HOT WATER SYSTEM SHALL BE ENABLED WHEN OUTDOOR AIR TEMPERATURE IS LESS THAN 60°F (ADJ) AND AVERAGE ZONE LOAD IS GREATER THAN 10%. FOR FREEZE PROTECTION THE HOT WATER SYSTEM SHALL REMAIN ENABLED WHEN OUTDOOR AIR TEMPERATURE IS LESS THAN 35°F (ADJ). WHEN ENABLED THE HOT WATER SYSTEM SHALL RUN FOR A MINIMUM OF 20

MINUTES (ADJ).

BOILER CONTROL: THE BOILERS ARE SUBJECT TO THEIR HARDWIRED SAFETIES. WHEN THE SYSTEM IS ENABLED THE LEAD BOILER AND LEAD HOT WATER LOOP PUMP SHALL RUN. THE BOILERS SHALL BE CONFIGURED BY AN LOCHINVAR FACTORY QUALIFIED TECHNICIAN TO RUN IN CASCADE MODE. THE ROTATION AND STAGING OF THE BOILERS SHALL BE CONTROLLED BY THE CASCADE SEQUENCE INTEGRAL TO THE BOILERS. A NETWORK CONNECTION BETWEEN THE BOILERS SHALL BE PROVIDED AND WIRED BY TCC.

HOT WATER LOOP PUMPS: WHEN THE SYSTEM IS ENABLED, A SINGLE HOT WATER PUMP SHALL RUN. THE PUMP SPEED SHALL BE CONTROLLED TO MAINTAIN A SYSTEM DIFFERENTIAL OF 15 PSI (ADJ). THE PUMPS SHALL ROTATE ON ONE OF THE FOLLOWING SELECTABLE CONDITIONS, MANUALLY THROUGH SOFTWARE SWITCH, ON RUNTIME, DAILY, WEEKLY, OR MONTHLY. IF A PUMP IS COMMANDED ON, AND NO STATUS IS DETECTED, A PUMP FAILURE ALARM SHALL BE SENT. IF A PUMP HAS AN ON STATUS, AND IS NOT

COMMANDED ON, A PUMP IN HAND ALARM SHALL BE SENT.

HOT WATER SUPPLY TEMPERATURE CONTROL: THE HOT WATER SUPPLY TEMPERATURE SET POINT SHALL BE RESET TO OUTDOOR AIR TEMPERATURE BY THE BMS. EEEA HWS TEMPERATURE WELL SENSOR IS PROVIDED WITH THE BOILERS AND SHALL BE WIRED BY

TCC, MOUNTED BY OTHERS.

IF HOT WATER TEMPERATURE IS GREATER THAN 10°F (ADJ) BELOW SET POINT FOR MORE THAN 20 MINUTES (ADJ), A HOT WATER

SYSTEM TEMPERATURE FAIL ALARM SHALL BE SENT TO THE BMS.

THE NEW CONTROLS SHALL COMMUNICATE SEAMLESSLY WITH THE EXISTING ALERTON BUILDING MANAGEMENT SYSTEM

2 1/2" HW

5"HWS

5"HWR

4"HWR

4"HWR

4"HWS 4"HWS

CONNECT 4"HWS TO EXISTING

CONNECT 2 12"HW TO EXISTING

4"HWS IN THIS AREA

CONNECT 2 12"HW TO EXISTING

4"HWR IN THIS AREA

CONNECT 4"HWR TO EXISTING

4"HWS IN THIS AREA

2 1/2" HW

EXISTING

CIRCULATING

PUMP (typ.)

M1.2

TEMPERATURE

CONTROLS AND

PIPING

SCHEMATIC

DIAGRAMS

C O

PY

R

IG

H

T C

Th is d ra w in g is a n in st ru m en t o f s er vi ce a nd sh al l r em ai n th e pr op er ty of B em is

A ss oc ia te s L

LC

, w he th er th e pr oj ec t f or w hi ch it is in te nd ed is c on st ru ct ed o r n ot

Th is d ra w in g, a nd th e co nc ep ts a nd id ea s co nt ai ne d he re in

, s ha ll no t b e us ed

, c op ie d or re ta in ed w ith ou t t he ex pr es s w rit te n ap pr ov al o f B em is

A ss oc ia te s L

LC

Su bm is si on o r d is tri bu tio n of th is d ra w in g to m ee t o ff ic ia l r eg ul at or y re qu ire m en ts o r f or o th er p ur po se s i n co nn ec tio n w ith th e pr oj ec t i s n ot to b e co ns tru ed a s p ub lic at io n in d er og at io n of a ny o f t he ri gh ts o f

B em is A ss oc ia te s L

LC

A ny a br id ge m en t o r v io la tio n of th e rig ht s o f B em is A ss oc ia te s L

LC

sh al l b e pr os ec ut ed to th e fu lle st e xt en t p os si bl e un de r t he la w

D A

N B

U R

Y C

T

B O

IL

ER

R

EP

LA

C

EM

EN

T W

C

SU

C

LA

SS

R O

O M

B U

IL

D

IN

M

12 25

N

O

P

Q

M

12 25

N

O

P

Q

MECHANICAL ROOM PART PLAN - ELECTRICAL NEW WORK

SCALE: 1/4"=1'-0"

MECHANICAL ROOM PART PLAN - ELECTRICAL DEMOLITION

SCALE: 1/4"=1'-0"

EXIST.

BOILER

B#2

EXIST.

BOILER

B#1

EXIST. AHU-1

EXIST.

P-5

EXIST.

AHU-5

NEW

BOILER

B#1

BP-1

ELECTRICAL KEY NOTES - DEMOLITION

TAG DESCRIPTION

EXISTING BOILER #1 TO BE DISCONNECTED AND REMOVED BY HVAC CONTRACTOR. E.C. SHALL

DISCONNECT & REMOVE EXISTING BOILER AND CIRCULATION PUMP ELECTRICAL, MAKE SAFE FOR

INSTALLATION OF NEW.

ELECTRICAL DRAWING LEGEND

SYMBOLS

ABOVE FINISHED FLOOR (CENTERLINE OF DEVICE OR EQUIPMENT).

NOT TO SCALE.

GROUND.

NTS

GFCI

GND or G

CONDUIT.C

CIRCUIT BREAKER.C/B

AMPS.

ALTERNATING CURRENT.

AFF

A

AC

ABBREVIATIONS

AMERICAN WIRE GAUGE.AWG

JUNCTION BOX.JB

VARIABLE FREQUENCY DRIVE.VFD

EQUIPMENT POWER CONNECTION, EQUIPMENT TYPE AS

DESIGNATED.

MOTOR POWER CONNECTION, EQUIPMENT TYPE AS DESIGNATED.

INDICATES DEVICE WITH INTEGRAL GROUND FAULT

CIRCUIT INTERRUPTER.

EXISTING(E)

LOW VOLTAGE.LV

ELECTRICAL KEY NOTES - NEW WORK

TAG DESCRIPTION

NEW BOILER AND CIRCULATOR PUMP FURNISHED AND INSTALLED BY HVAC CONTRACTOR. E.C. SHALL CONNECT NEW BOILER #1 AND NEW CIRCULATOR PUMP BP-1 TO EXISTING BRANCH CIRCUITS MADE AVAILABLE BY REMOVAL, MODIFY / EXTEND EXISTING BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CONNECTION TO NEW EQUIPMENT AND EXISTING EMERGENCY OFF SWITCH (MAINTAIN

CONTINUITY)

PHASE.Ø

TRANSFORMER.TX

1 - PRIOR TO SUBMITTING BID, VISIT THE SITE AND IDENTIFY EXISTING CONDITIONS AND DIFFICULTIES THAT WILL AFFECT WORK TO BE PERFORMED. NO COMPENSATION WILL BE GRANTED FOR ADDITIONAL WORK CAUSED BY UNFAMILIARITY WITH SITE CONDITIONS THAT ARE VISIBLE OR READILY CONSTRUED BY EXPERIENCED OBSERVERS. INCLUDE IN THE BID

ALL DEMOLITION WORK REQUIRED.

2 - tHE DEMOLITION DRAWINGS ARE INTENDED ONLY TO DEFINE THE GENERAL SCOPE OF DEMOLITION WORK AND TO ASSIST THE CONTRACTOR DURING BIDDING. THE DEMOLITION DRAWINGS MAY NOT SHOW EVERY ITEM WHICH MUST BE DISCONNECTED, REMOVED, OR RELOCATED IN ORDER TO FACILITATE NEW WORK. THE CONTRACTOR SHALL BE

RESPONSIBLE FOR ALL DEMOLITION WORK REQUIRED WHETHER OR NOT SHOWN ON THE PLANS.

3 - REMOVE AND/OR RELOCATE ALL EXISTING ELECTRICAL WORK AS NECESSARY FOR THE PERFORMANCE OF THE WORK

OF THIS CONTRACT.

4 - EXISTING ELECTRICAL EQUIPMENT, WIRING, AND RACEWAYS SHALL NOT BE REUSED UNLESS SPECIFICALLY NOTED

OTHERWISE.

5 - REMOVE ALL DEMOLITION MATERIAL FROM THE JOB SITE UNLESS NOTED DIFFERENTLY. MATERIAL REQUESTED BY THE OWNER FOR SALVAGE SHALL BE DELIVERED TO THE OWNER'S DESIGNATED MATERIAL STORAGE AREA.

6 - PROVIDE WIRING AS REQUIRED AND RECONNECT EXISTING FIXTURES, DEVICES, OR EQUIPMENT THAT ARE TO REMAIN ACTIVE, BUT HAVE BEEN DISCONNECTED DURING DEMOLITION OF OTHER FIXTURES, DEVICES, OR EQUIPMENT.

ELECTRICAL DEMOLITION WORK NOTES GENERAL SPECIFICATION NOTES - POWER

1 - THE CONTRACTOR SHALL VERIFY AND OBTAIN ALL NECESSARY DIMENSIONS AT THE BUILDING.

2 - FINISHED WORK: THE INTENT OF THE SPECIFICATIONS AND DRAWINGS IS TO CALL FOR FINISHED WORK, COMPLETED, TESTED AND READY FOR OPERATION.

3 - GOOD PRACTICE: IT IS NOT INTENDED THAT THE DRAWINGS SHOW EVERY CONDUIT, JUNCTION BOX, FITTING OR MINOR DETAIL AND IT IS UNDERSTOOD THAT WHILE THE DRAWINGS MUST BE FOLLOWED AS CLOSELY AS CIRCUMSTANCES WILL PERMIT, THE SYSTEMS SHALL BE INSTALLED ACCORDING TO THE INTENT AND MEANING OF

THE CONTRACT DOCUMENTS AND IN ACCORDANCE WITH GOOD PRACTICE.

4 - ANY APPARATUS, APPLIANCE, MATERIAL OR WORK NOT SHOWN ON DRAWINGS BUT MENTIONED IN SPECIFICATIONS OR VICE VERSA, OR ANY INCIDENTAL ACCESSORIES NECESSARY TO MAKE THE WORK COMPLETE AND PERFECT IN ALL RESPECTS AND READY FOR OPERATION, EVEN IF NOT PARTICULARLY SPECIFIED, SHALL BE FURNISHED AND

INSTALLED BY CONTRACTOR AT NO ADDITIONAL COST TO OWNER.

5. CODES AND STANDARDS - COMPLY WITH ALL FEDERAL, STATE AND LOCAL CODES AND STANDARDS WHEREVER

APPLICABLE INCLUDING THE FOLLOWING:

2022 CONNECTICUT STATE BUILDING CODE, (2021 IBC WITH AMENDMENTS),

2022 CONNECTICUT FIRE SAFETY CODE , (2021 IFC WITH AMENDMENTS),

2022 CONNECTICUT STATE FIRE PREVENTION CODE (2021 NFPA 1 WITH AMENDMENTS),

2021 INTERNATIONAL ENERGY CONSERVATION CODE WITH AMENDMENTS,

2021 INTERNATIONAL PLUMBING CODE WITH AMENDMENTS,

2021 INTERNATIONAL MECHANICAL CODE WITH AMENDMENTS,

2020 NFPA 70 NATIONAL ELECTRICAL CODE WITH AMENDMENTS,

2019 NFPA 72 NATIONAL FIRE ALARM CODE,

ICC A117.1-2017 ACCESSIBLE AND USABLE BUILDINGS,

ADA.

NFPA,

UNDERWRITERS LABORATORIES,

FACTORY MUTUAL INSURANCE COMPANY,

NEMA STANDARDS.

6 - NOTE THAT THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF THE ELECTRICAL

EQUIPMENT AND SYSTEMS, WITHOUT SHOWING EVERY DETAIL AND FITTING.

7 - RACEWAYS: PROVIDE EMT CONDUIT FOR ALL WIRING. EMT CONNECTORS AND COUPLINGS SHALL BE GALVANIZED STEEL SET-SCREW TYPE. PROVIDE GLAND COMPRESSION CONNECTORS AND COUPLINGS WHERE LOCATED IN DAMP AND WET LOCATIONS. PROVIDE FLEXIBLE STEEL CONDUIT FOR FINAL CONNECTIONS TO MOTOR DRIVEN EQUIPMENT.

8 - BRANCH CIRCUIT CONDUCTORS SHALL BE COPPER, RATED 600 VOLTS, 90 DEG.C., COLOR CODED, TYPE XHHW-2.

9 - WIRE SIZE #8 AWG AND LARGER SHALL BE STRANDED. WIRE OF SIZE SMALLER THAN #8 AWG SHALL BE SOLID.

10 - MINIMUM SIZE CONDUCTORS FOR POWER AND LIGHTING SHALL BE #12 AWG. PROVIDE MINIMUM #10 AWG SIZE FOR RUNS EXCEEDING 75' IN CONDUCTOR LENGTH, AND #8 AWG SIZE FOR RUNS EXCEEDING 150' IN CONDUCTOR

LENGTH. PROVIDE LARGER SIZE CONDUCTORS AS SCHEDULED OR AS NOTED ON THE DRAWINGS.

11 - RACEWAYS SHALL BE CONCEALED WHEREVER POSSIBLE IN ALL FINISHED AREAS.

12 - RACEWAYS SHALL BE RUN PARALLEL TO OR AT RIGHT ANGLES TO WALL LINES.

13 - RACEWAYS SHALL BE SUPPORTED FROM THE STRUCTURE BY STRAP HANGERS, ROD HANGERS, OR RACK

MOUNTED, OR OTHER APPROVED ELECTRICAL MOUNTING.

14 - OUTLET BOXES SHALL BE EQUIPPED WITH FIXTURE STUD OR STRAPS WHERE REQUIRED.

15- INSTALL BOXES IN ACCESSIBLE LOCATIONS AND AT UNIFORM HEIGHTS.

16 - SET BOXES AND COVERS SQUARE AND TRUE WITH BUILDING FINISH.

EXIST.

BOILER

B#2

EXIST. AHU-1

EXIST.

P-5

EXIST.

AHU-5

BP-2 (ADD ALT #1)

E1.1

MECHANICAL RM.

PART PLAN

ELECTRICAL

DEMOLITION &

NEW WORK

C O

PY

R

IG

H

T C

Th is d ra w in g is a n in st ru m en t o f s er vi ce a nd sh al l r em ai n th e pr op er ty of B em is

A ss oc ia te s L

LC

, w he th er th e pr oj ec t f or w hi ch it is in te nd ed is c on st ru ct ed o r n ot

Th is d ra w in g, a nd th e co nc ep ts a nd id ea s co nt ai ne d he re in

, s ha ll no t b e us ed

, c op ie d or re ta in ed w ith ou t t he ex pr es s w rit te n ap pr ov al o f B em is

A ss oc ia te s L

LC

Su bm is si on o r d is tri bu tio n of th is d ra w in g to m ee t o ff ic ia l r eg ul at or y re qu ire m en ts o r f or o th er p ur po se s i n co nn ec tio n w ith th e pr oj ec t i s n ot to b e co ns tru ed a s p ub lic at io n in d er og at io n of a ny o f t he ri gh ts o f

B em is A ss oc ia te s L

LC

A ny a br id ge m en t o r v io la tio n of th e rig ht s o f B em is A ss oc ia te s L

LC

sh al l b e pr os ec ut ed to th e fu lle st e xt en t p os si bl e un de r t he la w

D A

N B

U R

Y C

T

B O

IL

ER

R

EP

LA

C

EM

EN

T W

C

SU

C

LA

SS

R O

O M

B U

IL

D

IN

Sheets and Views
Cover (36x24)

File details come from the government source that posted it. Updated .