2-PROJECT DRAWINGS - NOBLE HOUSE - 2026 02 26.pdf
PDF 16 MB Posted
- Attached to
- Noble House
- Solicitation number
- Not on record
- Issued by
- Northampton County, Pennsylvania
About this file
This is a project drawings document for the Noble House renovation project undertaken by St. John's United Church of Christ in Nazareth, Pennsylvania. The project involves the conversion of an existing 2½-story wood frame residential structure located at 201 South Broad Street into two individual dwelling units to provide affordable housing. The first-floor unit will contain 860 square feet with two bedrooms and a new full bathroom, while the second-floor unit will contain 971 square feet (including 142 square feet on the first floor and 829 square feet on the second floor) with one bedroom. The work includes selective demolition, new wall and floor/ceiling assemblies for required compartmentation, roofing replacement (EPDM membrane on portions and asphalt shingles on others), new interior finishes, mechanical systems (two separate HVAC systems with Trane furnaces and cooling units), electrical systems with separate panels for each unit, and plumbing systems with new fixtures. Sealed bids are due by 10:00 A.M. on Tuesday, March 31, 2026, via the PennBid Program, with contract documents available beginning February 26, 2026. A pre-bid meeting is scheduled for Thursday, March 12, 2026, at 10:00 A.M. at the project site.
The project is structured with four prime contracts: General Construction, Mechanical Construction, Electrical Construction, and Plumbing Construction. Bidders must provide a Bid Bond equal to five percent of the total bid amount, with successful bidders required to furnish Performance and Payment Bonds each equal to one hundred percent of the contract value. The project is subject to the Davis-Bacon Act of 1931, requiring prevailing wage rates to apply to all work. The building is classified as Group R-3 residential occupancy under the 2018 International Building Code and 2018 International Residential Code, with fire-rated wall and floor/ceiling assemblies between units and one-hour compartmentation required. The existing structure will retain its 2½-story height and Type VB wood frame construction classification. All work must be guaranteed free from defects in material and workmanship for one year from completion, with the contractor responsible for removing demolition debris and protecting the existing structure during construction. The project owner is Rev. Jeffrey A. Brinks, Pastor of St. John's United Church of Christ, with authority having jurisdiction being Nazareth Borough, Northhampton County, Pennsylvania.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Axonometric - Existing Conditions Scale: 3/32" = 1'-0"
East Prospect Street
South Broad Street
BUILDING CODE DATA:
(reviewed under IBC 2018 & IRC 2018)
BUILDING LOCATION:
201 S. Broad Street Nazareth, PA 18064
Property Owner: ST JOHNS UNITED CHURCH OF CHRIST
SOUTH BROAD & E PROSPECT STS
NAZARETH, PA, 18064
ZONING DISTRICT: Medium Density Residential District - Nazareth Borough
BUILDING HEIGHT :
2 1/2 Stories (Existing - no change)
BUILDING CONSTRUCTION TYPE :
Type VB Wood Frame
OCCUPANCY USE:
Group R-3 Dwelling - Two Family
TENANT AREAS:
Dwelling Unit 100 at First Floor: 860 g.s.f.
Dwelling Unit 200 at Second Floor: 142 g.s.f. + 829 g.s.f. = 971 g.s.f.
Section 420 Fire Partitions per section 708 to be 1 hour rated Horizontal Assemblies per 7112.4.3 to be 1 hour rated (non-sprinklered building)
Occupant Load:
Dwelling Unit 100: 860 g.s.f./200 = 5 occupants Dwelling Unit 200: 971 g.s.f./200 = 5 occupants
MEANS OF EGRESS:
Table 1017.2 - 200' max. exit access travel distance allowed
FIRE SUPRESSION SYSTEM: Not required Building is not sprinklered
INTERIOR FINISH (Table 803.13):
Group R-3: Interior Exit Stairways, Corridors, Exit enclosures & Passageways - Class C Rooms & enclosed spaces - Class C
FIRE EXTINGUISHERS: Not required
MEANS OF EGRESS LIGHTING : (IRC Section 303.7) Interior stairways shall be provided with an artificial light source to illuminate the landings and treads. The light source shall be capable of illuminating treads and landings to levels of not less than 1 foot-candle (11 lux) as measured at the center of treads and landings. There shall be a wall switch at each floor level to control the light source where the stairway has six or more risers.
Project Location Not To Scale
LOCATION OF
PROJECT
1. General Notes:
- Do not scale these drawings; use written dimensions only.
- Notify Architect immediately if assumed existing conditions are other than shown.
- Labor, materials and workmanship shall be in accordance with the industry standards.
2. Insurance:
Each Contractor and subcontractor shall not commence work under the contract until he has provided proof of insurance of such character and in such amounts as will provide adequate protection for the owner, the members thereof, and their successors, all agents officers and servants of the owner, and the contractor and subcontractor against all claims, liabilities, damages and accidents. Such insurance to remain in force throughout the life of the contract.
3. Demolition/Support:
- GC shall safely remove all demolition debris from the site to the appropriate disposal facility.
- GC shall provide temporary support of existing structure to be removed.
- GC shall take precautionary measures to protect existing house during construction.
4. Landscaping:
GC shall protect existing plants and grass during construction. Reseed disturbed grass areas.
5. Temporary Service:
Owner shall be responsible for providing water and electric at the required work area.
6. Guarantees:
All work performed as a part of the contract is to be guaranteed by the contractor and/or subcontractor to be free from defects in material and workmanship for a period of one (1) year from the date of completion of work; the contractor and/or subcontractor agrees to return to the job and make repairs and/or replacement to such defects at no cost to the owner. Final payment shall be made at a substantial completion, less the value of the final punch list. Punch list value will be paid at the completion of work. General Contractor shall turn over to owner all documents, manuals, guarantees, etc for all devices, equipment and appliances.
7. Permits:
Each Contractor/Sub-contractor shall file for necessary building permits. The Owner shall be responsible for the cost of the permits.
PROJECT SUMMARY
The existing single family residence at 201 S. Broad Street is a 2 1/2 story wood frame structure with brick veneer exterior. The first floor area is 1,017 s.f. and the second floor area is 829 s.f. It is desired to convert the structure into (2) individual dwelling units in order to provide affordable housing. The proposed first floor unit will be a two bedroom with a new full bathroom. The proposed second floor unit will be a one bedroom unit and will incorporate the existing first floor hallway and stairs as part of the unit. Existing wall and floor/ ceiling assemblies are to be altered to provide required compartmentation and reduce sound transmission.
1. Applicable Code(s) & Regulations For This Project.
State: Pennsylvania
2018 IBC (International Buidling Code) & 2018 IRC (International Residential Code) PA Uniform Construction Code (Regulations and Statutes)
2. Occupancy Use Classification(s): R-3 Residential
3. Construction Type(s) / Classification(s): 5B
4. Project Description: 2 Story Residential
Area:
Dwelling Unit 100 - 1st Floor - 860 s.f.
Dwelling Unit 200 - 1st Floor - 142 s.f.
2nd Floor - 829 s.f.
5. Fire Protection Systems: Smoke Alarm and CO Alarm
6. Date(s) of Original Construction: N/A
7. Authority Having Jurisdiction: Nazareth Borough, Northhampton County, Pennsylvania
8. Building Owner:
Contact: Rev. Jeffery A. Brinks Pastor of St. John’s United Church of Christ 183 S. Broad Street Nazareth, PA 18064 pastor@sjuccnaz.org. Office: 610.759.0893
INDEX OF DRAWINGS
Architectural A0.1 Building Code Data, Site Plan & Compartmentation D1.1 Basement, First & Second Floor Demolition Plans A1.1 Basement, First & Second Floor Plans, Finish Specifications A2.1 Exterior Elevations A3.1 Enlarged Plans & Interior Elevations A4.1 Door Schedule, Floor/ Ceiling & Partition Types
Mechanical H.1 HVAC Notes H.2 HVAC Plans H.3 HVAC Attic Plan & Details
Electrical E.1 Electrical Notes E.2 Electrical Power Plan E.3 Electrical Lighting Plan E.4 Electrical Details
Plumbing P.1 Plumbing Notes P.2 Sanitary Piping Plans P.3 Potable Water Piping Plans P.4 Natural Gas Piping Plans
Site Plan Scale: 1/8" = 1'-0"
South Broad Street
E as t P ro s p e c t
S tr e e t
NORTH
7' -0
19'-0" typical stall
Provide striping for
(3) new parking spaces
Extend exist. asphalt paving; grade area as required & install new pavement: 1 1/2" macadam wearing course on 2 1/2" binder course on 4" crushed stone on compacted grade
Exist. 2 1/2 story residence to be converted into (2) units
Exist. garage to remain
E x is t.
P av e d A re a ar e a o f ne w p av in g
Exist. stairs to remain
Provide PVC fence enclosure and trash receptacle
Parking Note:
(2) additional parking spaces are being reserved at the opposite side of the church owned lot to create a total of
(5) spaces.
1st Floor
1017 sq ftUnit
860 sq ft
Unit
142 sq ft lav
First Floor Unit Plan Scale: 3/32" = 1'-0"
A A0.1
A A0.1
(Stair/ Hallway only)
Line of 1 hour wall assembly
Unit
829 sq ft
Second Floor Unit Plan Scale: 3/32" = 1'-0"
A A0.1
A A0.1
Compartmentation Building Section Scale: 1/8" = 1'-0"A
F2
F1
Line of 1 hour wall & ceiling assembly
Finish Floor-B -8'-0"
Finish Floor-1 0"
Finish Floor-2 10'-2"
Dwelling Unit 100
Dwelling Unit 200
Exist. attic (mechanical/ storage for Unit 200)
Exist. basement (mechanical/ storage for Unit 200) Sheet No.
Drawn By
Reviewed ByDate
A0.1
GaL
GaL26 April 2024
Sheet Title
P ro je ct
T itl e
Building Code Data, Site Plan &
Compartmentation
Pr op os ed
A lte ra tio ns fo r:
N ob le
H ou se
Architect
S B ro ad
S tre et N az ar et h, P A
NO. DATE ISSUE NOTE
REV. DATE DESCRIPTION
Project Manager
GaL
Project ID
St John_201 S Broad_Exist
FO
R
P E
R M
IT
JU
LY
, 2
All drawings and written materials appearing herein constitute original and unpublished work of the architect and may not be used or disclosed without prior consent of
4/4 Architecture, LLC Copyrighted 2024
Proposed Alterations for:
Noble House
201 S Broad Street Nazareth, PA 18064
GaL
1 7/3/24 For Permit
BID SET
02.26.2026
Sheet No.
Drawn By
Reviewed ByDate
D1.1
GaL
GaL26 April 2024
Sheet Title
P ro je ct
T itl e
Basement, First & Second Floor
Demolition Plan
Pr op os ed
A lte ra tio ns fo r:
N ob le
H ou
S B ro ad
S tre et N az ar et h, P A
NO. DATE ISSUE NOTE
REV. DATE DESCRIPTION
Project Manager
GaL
All drawings and written materials appearing herein constitute original and unpublished work of the architect and may not be used or disclosed without prior consent of
4/4 Architecture, LLC Copyrighted 2024
1 7/3/24 For Permit
2nd Floor Plan Scale: 1/4" = 1'-0"NO
RT
H
Remove existing doors & frames, salvage for reuse
Demolish existing bathroom. Remove plumbing fixtures including cabinets and countertop
1st Floor Plan Scale: 1/4" = 1'-0"NO
RT
H
Remove all existing kitchen cabinets, appliances and sink
Provide opening for new door, see door schedule
Enlarge existing openings for new doors, see door schedule
Remove existing door & frame, salvage for reuse
Remove existing door & frame, salvage for reuse
Remove existing door & frame, salvage for reuse
Demolish existing walls and floor tile.
Remove plumbing fixtures
Demolish existing stair to basement
Remove existing carpet from staircase
Remove existing exhaust fan
Remove existing lay-in ceiling above
Remove existing wall paper, patch & prepare for new paint finish
2'-1"
Note:
Existing radiators to be removed throughout building. See Mech.
dwg's for further info.
Basement Plan Scale: 1/4" = 1'-0"NO
RT
H
Demolish existing stairs to first floor
GENERAL DEMOLITION NOTES
THE DEMOLITION DRAWINGS AND NOTES SHALL NOT BE CONSIDERED ALL-INCLUSIVE. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR INSPECTING AND ASSESSING EACH AREA AND
FULFILLING THE INTENT OF THE WORK INDICATED BY THE CONTRACT DOCUMENTS. FIELD
VERIFY ALL CONDITIONS WITHIN THE CONTRACT LIMITS. DEVIATIONS FROM THE
CONTRACT DOCUMENTS NECESSITATED BY THE FIELD CONDITIONS SHALL BE BROUGHT
TO THE ATTENTION OF THE ARCHITECT/ ENGINEER.
GIVE ADVANCE NOTICE TO THE OWNER WHEN WORK IS TO BE PERFORMED THAT COULD
INTERRUPT SERVICES TO OTHER AREAS. THE OWNER'S POLICY AND PROCEDURES IN THIS
REGARD SHALL BE STRICTLY ADHERED TO.
MAINTAIN AND PROTECT EXISTING UTILITIES TO REMAIN IN SERVICE BEFORE
PROCEEDING WITH DEMOLITION, PROVIDING BYPASS CONNECTION TO OTHER PARTS OF
THE BUILDING.
PROVIDE AND MAINTAIN SHORING, BRACING OR STRUCTURAL SUPPORT TO PRESERVE
BUILDING STABILITY AND PREVENT MOVEMENT, SETTLEMENT OR COLLAPSE.
PROTECT BUILDING STRUCTURE OR INTERIOR FROM WEATHER AND WATER LEAKAGE
DAMAGE.
PROTECT REMAINING WALLS, CEILINGS, FLOORS AND EXPOSED FINISHES. ERECT AND
MAINTAIN DUSTPROOF PARTITIONS AS NECESSARY DURING CONSTRUCTION. COVER AND
PROTECT REMAINING EQUIPMENT.
PROMPTLY PATCH AND REPAIR HOLES AND DAMAGED SURFACES OF BUILDING CAUSED BY
DEMOLITION. RESTORE EXPOSED FINISHES OF PATCHED AREAS AND EXTEND FINISH
RESTORATION INTO REMAINING ADJOINING CONSTRUCTION.
PROMPTLY REMOVE DEMOLISHED MATERIALS FROM OWNER'S PROPERTY AND LEGALLY
DISPOSE OF THEM. DO NOT BURN DEMOLISHED MATERIALS. THE ITEMS SHALL BE
DISPOSED OF IN A PROPER MANNER IN ACCORDANCE WITH CITY AND STATE ORDINANCES,
LEAVING SURFACES CLEAN, SOLID AND READY TO RECEIVE NEW MATERIALS/FINISHES.
Reviewed ByDate
A1.1
GaL
GaL26 April 2024
Sheet Title
P ro je ct
T itl e
Basement, First & Second Floor Plan, Finish Specifications
Pr op os ed
A lte ra tio ns fo r:
N ob le
H ou
S B ro ad
S tre et N az ar et h, P A
NO. DATE ISSUE NOTE
REV. DATE DESCRIPTION
Project Manager
GaL constitute original and unpublished work of the architect and may not be used or disclosed without prior consent of
4/4 Architecture, LLC Copyrighted 2024
1 7/3/24 For PermitEXISTING WALL PARTITION
SYMBOL KEY
A WALL TYPE DESIGNATION, (SEE A4.1)
WALL PARTITION - DEMOLITION
NEW OR EXISTING DOOR
REMOVE EXISTING DOOR
WINDOW ID
NEW WALL PARTITION
DOOR ID (SEE DOOR SCHEDULE)01
FE FIRE EXTINGUISHER
MkA
Second Floor Plan Scale: 1/4" = 1'-0"NO
RT
H
B
B C
B
B A3.1
D
B Remove existing membrane roof & install new fully adhered EPDM roofing membrane to be Carlisle 'Sure-Seal' or approved equal.
Flash underneath intersection w/ new asphalt shingles.
Provide prefinished metal drip edge.
Remove existing membrane roof & install new fully adhered EPDM roofing membrane to be Carlisle 'Sure-Seal' or approved equal.
Remove existing asphalt shingle roof & install new over new underlayment
Provide new ice & watershield underlayment
General Roofing Note:
Upon removal of existing roofing system, inspect existing decking for any rot or deterioration, make repairs as required.
New Kitchen
Living Rm
Bedroom #1
New Bath
Exist. Stairs/ Hallway
Dining Area
Provide coat pole & shelf at exist. closet
Infill new wall construction to match exist. at former opening. Patch in new base moulding, paint
Fur out exist. wall w/ 2x4 studs filled w/ batt insulation. Apply 1/2" moisture resistant gyp. bd.
SD
CD
SD
SD
First Floor Plan Scale: 1/4" = 1'-0"NO
RT
H
B
B
A A3.1
B
A
Infill existing opening with new floor framing & subfloor to match exist. Prepare to receive new flooring
Clean & stain all trim, balustrade & railings at existing stair to remain
Kitchen
Living Rm
Bedroom #2
Bedroom #1
New Bath
Exist. Stairs/ Hallway
Exist. Vestibule
Existing Porch wardrobe/ armoire, see 10/ A3.1 wardrobe/ armoire, see 9/ A3.1
Exist. closet under stairs to remain
Assumed extent of exist. floor opening to be infilled
New condenser units, see mechanical dwg's
Hatch pattern denotes new carpeting throughout exist.
hallway
Infill new wall construction to match exist. at former door location. Patch in new base moulding, paint
Infill new wall construction to match exist. at former door location. Patch in new base moulding, paint
D
A
Entrance, Unit 100
Entrance, Unit 200
Fur out exist. wall w/ 2x4 studs filled w/ batt insulation. Apply 1/2" moisture resistant gyp. bd.
Exist.
stairs from parking to remain
Hatch pattern denotes LVT plank flooring
SD
CD
SD
SD
CD
Ceiling mounted smoke & carbon monoxide detectors, typ.
Basement Plan Scale: 1/4" = 1'-0"NO
RT
H
Slab on grade
See electrical dwg's for new panel locations
See mechanical dwg's for new equipment locations
Storage/ Mechanical
Storage/ Mechanical
Dashed line denotes extent of rated floor/ ceiling separation above
SD
CD
Keynotes 1.
2.
3.
Provide 1/2" 'Exacor' gypsum underlayment over exist. wood floor throughout, see floor/ ceiling assemblies drawing A4.1. Prepare to receive new finish flooring.
Provide new (non-rated) 1/2" gyb. bd. ceiling on suspension grid or furring where lay-in ceiling has been removed.
Provide & install new 1 hr. rated ceiling, see F2/A4.1 for further info
General Finish Notes 1.
2.
3.
4.
Install new flooring as specified over new underlayment Provide new base molding & casing to match existing at all new wall construction. Paint all moldings & casings as specified.
Patch, repair and paint all existing wall surfaces throughout. Paint as specified New ceiling to be provided at first floor unit where indicated. Paint all existing and new ceilings throughout.
Finish Specifications Item Description Manufacturer/ Product Color
Flooring LVT Roppe/ Premium Vinyl Wood Plank 273 limed pale oak Carpet Mohawk Group, Essential Elements Broadloom TBD
Base Trim & Casing Paint Sherwin Williams, Urethane Trim Enamel Pure White, Satin Finish
Walls Paint Sherwin Williams, Acylic Latex SW 7036, Accessible Beige, Eggshell Walls in Bathrooms " " SW 7036, Accessible Beige, Satin Finish
Ceiling Paint Sherwin Williams, Acylic Latex White, Flat Finish
Casework Factory finish White
Countertops Quartz Wilsonart Quartz Terlingua Q6024
Tile Backsplash Tile Daltile 3x6 MOD0100 WHITE STD
Note:
All finishes to be reviewed and approved by owner & architect prior to ordering. GC to provide actual finish samples and product information.
Reviewed ByDate
A2.1
GaL
GaL26 April 2024
Sheet Title
P ro je ct
T itl e
Exterior Elevations
Pr op os ed
A lte ra tio ns fo r:
N ob le
H ou
S B ro ad
S tre et N az ar et h, P A
NO. DATE ISSUE NOTE
REV. DATE DESCRIPTION
Project Manager
GaL constitute original and unpublished work of the architect and may not be used or disclosed without prior consent of
4/4 Architecture, LLC Copyrighted 2024
1 7/3/24 For Permit
West (Front) Elevation Scale: 1/8" = 1'-0"
Patch & repair rotted wood soffit, paint to match existing
Replace exist.
membrane roof over front porch. Provide & install new copper flashing, reget into brick joint
South (Side) Elevation Scale: 1/8" = 1'-0"
New sconce lighting, see electrical dwg's
Srape & paint exist.
sill & frame, typical
Power wash exist.
siding
Repair corner trim
Remove exist.
roofing & install new membrane roof
Remove exist. asphalt shingle roofing & install new asphalt shingle roof
Install new copper flashing, reglet into brick joint above previous installation
East (Rear) Elevation Scale: 1/8" = 1'-0"
Infill former vent opening w/ brick to match exist.
North (Side) Elevation Scale: 1/8" = 1'-0"
Srape & paint exist.
window sashes, sill & frame, typical
Reviewed ByDate
A3.1
GaL
GaL26 April 2024
Sheet Title
P ro je ct
T itl e
Enlarged Plans & Interior Elevations
Pr op os ed
A lte ra tio ns fo r:
N ob le
H ou
S B ro ad
S tre et N az ar et h, P A
NO. DATE ISSUE NOTE
REV. DATE DESCRIPTION
Project Manager
GaL constitute original and unpublished work of the architect and may not be used or disclosed without prior consent of
4/4 Architecture, LLC Copyrighted 2024
1 7/3/24 For Permit
Interior Elevation Scale: 3/8" = 1'-0"6
3'-3" 2'-9" 1'-9" 1'-0"
1'-3" 2'-0" d.w.
2'-9" sink
2'-9" corner unit
Wall cabinet w/adjustable shelving
Solid surface/quartz countertop with 4" backsplash
1' -6
Range hood
Ref. by Owner
Corner unit w/Lazy Susan
Unit w/blind corner
Stainless steel sink and faucet, see plumbing dwg's
Interior Elevation Scale: 3/8" = 1'-0"7
5'-0" 6"
Interior Elevation Scale: 3/8" = 1'-0"8
LAV
Prefinished painted wood cabinet
LED light fixtureStandard shower head & control
Shower rod
2'-6" 1'-6" 1'-6" 3'-0"
CL
Solid surface countertop
30"x36" surface mounted trifold mirror medicine cabinet2
Toilet paper dispenser
Standard 60" bathtub w/shower surround, see MEP dwg's for specs
2"
A3.1 lav
A3.1
First Floor Enlarged Plan Scale: 3/8" = 1'-0"A
3 1/2" 6'-10 1/2" 3 1/2"
/2
/2
/2
7/
/2
1'-8 3/4" 5 1/2"
5'-1 1/4" 3 1/2"
/4
1/
Set new wall construction adjacent to existing casing at exist. closet to remain
WORK PT.
Open storage: Provide adjustable shelves on standards
Kitchen
New Bath
Ref.
Interior Elevation Scale: 3/8" = 1'-0"4Interior Elevation
Scale: 3/8" = 1'-0"3
LAV
Prefinished painted wood cabinet
LED light fixture, see electrical dwg's
Standard shower head & control
Shower rod
3'-0" 1'-6" 1'-6" 2'-6"
CL
Solid surface countertop
30"x36" surface mounted trifold mirror medicine cabinet
Toilet paper dispenser
Standard 60" bathtub w/shower surround, see MEP dwg's for specs
2"
Interior Elevation Scale: 3/8" = 1'-0"1
3'-0" 2'-0" d.w.
2'-9" sink
1'-6" 2'-6" stove
1'-6"
3'-5" 5'-10 1/2" exist. window & casing (v.i.f.)
2'-6" 1'-6"
Solid surface/ quartz counter w/ 4" backsplash
Range hood
1' -2
Wall cabinet w/adjustable shelving
Base cabinet w/adjustable shelving
1' -6
New stainless steel sink & faucet, see plumbing dwg's
Ceramic tile backsplash
Interior Elevation Scale: 3/8" = 1'-0"2
Base cabinet w/adjustable shelving
Wall cabinet w/adjustable shelving
1' -2
1'-9" 1'-9" 1'-9" specified countertop with 4" backsplash
Wall tile
3'-6" 1'-9"
Refrig. by owner
CASEWORK BASIS OF DESIGN:
PROVIDE & INSTALL CABINETS & COMPONENTS AS
MANUFACTURED BY SCHROCK or approved equal. CABINET
HANDLES/ PULLS, DOOR STYLE & FINISH SELECTION BY
LANDLORD TO BE BASED ON FACTORY STANDARD
SELECTION.
TOILET ROOM ACCESSORIES:
1) Provide TOILET ROOM ACCESSORIES as shown in the drawings and specified below.
2) FURNISH & INSTALL IN EACH UNIT:
(1) 42" SQUARE TOWEL BAR
(1) 36" square towel bar
(1) HEAVY-DUTY ROBE HOOK,
3) COORDINATE FINAL INSTALLATION LOCATIONS W/ architect
General Interior & Casework Notes:
1. REFER TO MEP DWGS FOR FURTHER INFO.
2. ALL PARTITION DIMENSIONS ARE TO STUD DIMENSIONS. U.N.O.
3. PROVIDE MOISTURE RESISTANT GYPSUM DRYWALL IN ALL
BATHROOM WALLS AND AT OTHER WET WALLS.
4. CONTRACTOR TO VERIFY ALL DIMENSIONS AND PROVIDE FILLERS
for CASERWORK AS NECESSARY, FILLERS ARE NOT TO EXCEED 3".
5. VERIFY ALL BATH/SHOWER STALL DIMENSIONS WITH ACTUAL UNIT
PROVIDED. CONTRACTOR TO COORDINATE FRAMING, TUB
MANUFACTURER AND TUB DETAILS.
7. PROVIDE SUBMITTALS OF FIXTURES AND EQUIPMENT; SAMPLES OF
FINISHES; AND SHOPDRAWINGS OF ALL CASEWORK FOR ARCHITECT'S
REVIEW AND APPROVAL
8. EXTEND ALL FLOOR FINISHES UNDER SHELVING, AND REFRIGERATOR.
9. ALL APPLIANCES TO BE PROVIDED BY OWNER & INSTALLED BY GCArmoire Elevation Scale: 3/8" = 1'-0"10
5'-0" prefinished wood cabinet w/ panel doors, coat pole & shelf double drawer base w/ pulls
4" wood base
Armoire Elevation Scale: 3/8" = 1'-0"9
3'-6"
Interior Elevation Scale: 3/8" = 1'-0"5
Solid surface/quartz countertops with 4" backsplash
1' -2
Range hood
2'-9" corner unit
1'-0" 2'-6" stove
1'-6"
1' -6
1'-0 3/4" 2'-8 3/4" 2'-6" 1'-6"
Wall cabinet w/adjustable shelving
Base cabinet w/adjustable shelving
Corner unit w/Lazy Susan
Ceramic tile backsplashA3.1
A3.1
Second Floor Enlarged Plan Scale: 3/8" = 1'-0"B
5'-0 3/4" 3 1/2"
2 3/4" 5 1/2" 7'-10 1/4"
3'-8 1/2" 3 1/2" 1'-9" 3 1/2" 2'-10 1/2"
5'-0"
/4
/2
New Kitchen
New Bath
Ref.
Provide adjustable shelves at new linen closet
1/
/2
/2
/2
Door Schedule Nominal Size Door Frame
Mark W id th
H ei gh t
Th ic kn es s
D oo r E le va tio n
D oo r M at er ia l
G la z.
S ty le
Fr am e M at er ia l
Ja m b Th ic k
Ja m b D ep th
Fi re
R at in g
H W
S et
01 2'10" 6'8" 1 1/2" A SCWD None WD 1" 5" PRIVACY 02 2'10" 6'8" 1 1/2" A SCWD None WD 1" 4 1/2" PRIVACY 03 2'10" 6'8" 1 1/2" A SCWD None WD 1" 1'3" PRIVACY
04 2'9" 6'8" 1 3/4" Exist. None Exist. 1" 5 7/8" Entrance Exist. to remain, provide new Lockset
05 3'0" 7'0" 1 3/4" Exist. None Exist. 1" 5 7/8" Entrance Exist. to remain, provide new Lockset
21 3'6" 6'8" 1 1/2" B None 1" 5" --------- Bi-fold door 22 1'8" 6'8" 1 1/2" B None 1" 4 1/2" --------- Bi-fold door 23 2'6" 6'8" 1 1/2" A SCWD None WD 1" 4 1/2" PRIVACY
Sheet No.
Drawn By
Reviewed ByDate
A4.1
GaL
GaL26 April 2024
Sheet Title
P ro je ct
T itl e
Door Schedule, Floor/ Ceiling & Partition
Types
Pr op os ed
A lte ra tio ns fo r:
N ob le
H ou
S B ro ad
S tre et N az ar et h, P A
NO. DATE ISSUE NOTE
REV. DATE DESCRIPTION
Project Manager
GaL constitute original and unpublished work of the architect and may not be used or disclosed without prior consent of
4/4 Architecture, LLC Copyrighted 2024
1 7/3/24 For Permit
FLOOR/
CEILING
TAG
F-2 1 HR - 53/47 - -
FIRE RESISTANCE
RATING TEST Nº IIC TEST Nº
INSULAT.
ACOUSTICAL
PERFORMANCE
F2 - 1 Hr. Floor / Ceiling Assembly
E X
IS
T
/8
Fire Resistance Calculation Notes:
- Fire resistance has been determined per IBC 722 - Calculated Fire Resistance tables.
- Per IBC Sect. 722.6.2 (1) 5/8" type X Gyp. Bd. applied as a membrane adds 40 minutes to the fire rating for both wall & ceiling assemblies.
FLOOR/
CEILING
TAG
F-1 1 HR - - - -
FIRE RESISTANCE
RATING TEST Nº IIC TEST Nº
INSULAT.
ACOUSTICAL
PERFORMANCE
F1 - 1 Hr. Floor / Ceiling Assembly
Exist. (assumed) 2x8 floor joists @16" o.c.
Apply RC-1 resiliant channels @ 24" o.c.
Apply 1/2" Exacor underlayment over existing finish floor construction (hardwood floor on wood decking)
Exist. plaster on wood lath
Apply 5/8" type X gyp.
bd.
Exist. 2 x floor joists @16" o.c.
Apply 1/2" Exacor underlayment over existing finish floor construction (hardwood floor on wood decking)
Install 5/8" type X gyp. bd. to underside of exist. joists
3 1/2" sound attenuation blanket
Provide 3 1/2" thick sound attenuation blankets
E x is t.
F lo o r
C o ns tr uc ti o n m in ut e s
Floor/ Ceiling Assemblies Scale: 1 1/2" = 1'-0"
F-2 1 HR - 53/47 - -
INSULAT.
F2 - 1 Hr. Floor / Ceiling Assembly
Apply 1/2" Exacor underlayment over existing finish floor construction (hardwood floor on wood decking) head base plan
Base moulding to match exist.
5/8" Type X gyp bd (green board in damp locations) on either side of 2x4 studs w/ 3 1/2" sound attenuation blanket
New ceiling construction hung from existing, See compartmentation drawing, A0.1 and this sheet for further info.
WALL
TAG
A 1 Hr. UL 305 50 - None
FIRE RESISTANCE
RATING TEST Nº STC TEST Nº
INSULAT.
ACOUSTICAL
PERFORMANCE
A - 1 Hr Wall Construction
1/2" resilient channel on corridor side head base plan
Exist
30 min. calc. fire resistance
Exist. base to be removed & reinstalled over new gyp. bd.
New: 1 layer: 5/8" Type X gyp bd on RC channels on 2x4 studs w/ 3 1/2" sound attenuation blanket (40 minute additional fire resistance)
Existing stucco on wood lath wall
New ceiling construction hung from existing, See compartmentation drawing, A0.1 and this sheet for further info.
WALL
TAG
A1 1 Hr. - - - None
FIRE RESISTANCE
RATING TEST Nº STC TEST Nº
INSULAT.
ACOUSTICAL
PERFORMANCE
A1 - Existing Wall w/ new 5/8" Gyp. Bd. applied head base plan
Base moulding to match exist.
1/2" gyp bd (green board in damp locations) on interior side of 2x4 studs
New ceiling construction hung from existing, See compartmentation drawing, A0.1 and this sheet for further info.
WALL
TAG
D - - - - None
FIRE RESISTANCE
RATING TEST Nº STC TEST Nº
INSULAT.
ACOUSTICAL
PERFORMANCE
D - Non-Rated Partition head base plan
Base moulding as specified
1/2" gyp bd (green board in damp locations) on either side of 2x6 studs w/ sound attenuation blankett, as required for plumbing or to match exist. construction
New ceiling construction hung from existing, See compartmentation drawing, A0.1 and this sheet for further info.
WALL
TAG
C - - - - None
FIRE RESISTANCE
RATING TEST Nº STC TEST Nº
INSULAT.
ACOUSTICAL
PERFORMANCE
C - Non-Rated 2x6 Partition head base plan
Base moulding to match exist.
1/2" gyp bd (green board in damp locations) on either side of 2x4 studs
New ceiling construction hung from existing, See compartmentation drawing, A0.1 and this sheet for further info.
WALL
TAG
B - - - - None
FIRE RESISTANCE
RATING TEST Nº STC TEST Nº
INSULAT.
ACOUSTICAL
PERFORMANCE
B - Non-Rated Partition
Wall Assemblies/ Partition Types Scale: 1 1/2" = 1'-0"
GENERAL DOOR & HARDWARE NOTES
1.
2.
3.
Provide door hardware as manufactured by Schlage or approved equal. Finish to match existing Unless noted otherwise, or located on a centerline, locate finish opening 6" from adjacent wall.
Confirm all keying and hardware function requirements with owner.
Door Types s e e s c h e d ul e varies see schedule
Solid core panel bi-fold door, paint
Casing to match exist., paint
Elevation 'B' s e e s c h e d ul e varies see schedule
Solid core panel door to match existing, paint
Casing to match exist., paint
Elevation 'A'
Reviewed ByDate
26 April 2024
Sheet Title
Pr oj ec t T itl e
Pr op os ed
A lte ra tio ns fo r:
N ob le
H ou se
Architect
S Br oa d
St re et N az ar et h, P A
NO. DATE ISSUE NOTE
REV. DATE DESCRIPTION
Project Manager
Project ID
St John_201 S Broad_Exist
All drawings and written materials appearing herein constitute original and unpublished work of the architect and may not be used or disclosed without prior consent of 4/4 Architecture, LLC
Copyrighted 2024
A 6/1/24 FOR REVIEW & COMMENT
B 1/26/26 FOR PRICING
HVAC
NOTES
n
Sheet No.
Drawn By
Reviewed ByDate
26 April 2024
Sheet Title
Pr oj ec t T itl e
Pr op os ed
A lte ra tio ns fo r:
N ob le
H ou se
Architect
S Br oa d
St re et N az ar et h, P A
NO. DATE ISSUE NOTE
REV. DATE DESCRIPTION
Project Manager
Project ID
St John_201 S Broad_Exist
All drawings and written materials appearing herein constitute original and unpublished work of the architect and may not be used or disclosed without prior consent of 4/4 Architecture, LLC
Copyrighted 2024
A 6/1/24 FOR REVIEW & COMMENT
B 1/26/26 FOR PRICING
HVAC
PLANS
FURNACE SCHEDULE
TAG AREA SERVED MANU MODEL CFM
HEATING POWER
COMMENTS
TYPE CONNECTION INPUT MBH OUTPUT MBH VOLT PHASE AMPS MOP
FURN-1 FIRST FLOOR APARTMENT TRANE S9X1B04D3PSB
A 600 NG 1 5/8 40 38.8 120V 1 8.8 15
FURN-2 SECONDF FLOOR
APARTMENT TRANE S9X1B04D3PSB
A 800 NG 1 5/8 40 38.8 120V 1 8.8 15
DUCTED COOLING COIL SCHEDULE
TAG AREA SERVED MANU MODEL CFM
COOLING POWER
COMMENTS
TYPE NET MBH SENS MBH LAT MBH VOLT PHASE AMPS MOP
CC-1 FIRST FLOOR APARTMENT TRANE 4TXC 600 ELECTRIC 17.80 12.30 5.50 120V 1 1 15
CC-2 SECOND FLOOR APARTMENT TRANE 4TXC 800
CONDENSING UNIT SCHEDULE
TAG AREA SERVED MANU MODEL
COOLING POWER
COMMENTS
TYPE NET MBH SENS MBH LAT MBH VOLT PHASE AMPS MOP
CU-1 FIRST FLOOR APARTMENT TRANE 4TTR4018N1 ELECTRIC 17.80 12.30 5.50 208V 1 14 25 CU-2 SECOND FLOOR APARTMENT TRANE 44TR4024N1 ELECTRIC 22.30 16.90 5.40 208V 1 14 25
EXHAUST FAN SCHEDULE
SYMBOL MANU MODEL TYPE CFM ESP (IN. WC) HP (WATTS) DRIVE BELT / DIRECT WEIGHT (LBS) MAX SONES AMPS VOLTS / PHASE REMARKS
EF-1 BROAN AE110K CEILING 110 0.1 (23.4) DIRECT 10 1 0.3 120 1, 2
EF-2 BROAN AE110K CEILING 110 0.1 (23.4) DIRECT 10 1 0.3 120 1, 2
DUCT INSULATION [PER IECC C403.11.1]
KEY DESCRIPTION R-VALUE REQUIREMENT
1 INSULATION OF UNIT
CASING
FACTORY-INSTALLED INSULATION THAT IS PART OF THE HVAC EQUIPMENT IS
COVERED THROUGH MINIMUM EQUIPMENT EFFICIENCIES IN C403.3.2 [SEE
EXCEPTION 1 IF APPLIES]
NOT REQUIRED
2 EXHAUST ONLY TO PREVENT CONDENSATION IF NECESSARY NOT REQUIRED
3 SUPPLY & RETURN IN
VENTED ATTIC
CRAWL SPACES AND ATTICS VENTED OR OTHERWISE OPEN TO THE
OUTDOORS ARE CONSIDERED UNCONDITIONED SPACES R-6
4 SUPPLY & RETURN IN
EXTERIOR OF BUILDING EXPOSED DUCTWORK ON EXTERIOR OF BUILDING MUST HAVE INSULATION
CLIMATE ZONE 1-4 R-8
CLIMATE ZONE 5 R-12
5 SUPPLY & RETURN IN
SHAFT EXPOSED SHAFT IS CONSIDERED UNCONDITIONED R-6
6 SUPPLY & RETURN IN
UNVENTED ATTIC
DUCTS IN UNVENTED ATTIC COMPLETELY IN BUILDING ENVOLOPE IS
CONSIDERED A CONDITIONED SPACE NOT REQUIRED
SUPPLY IN INDIRECTLY
CONDITIONED CEILING
SPACE
DUCTS IN UNVENTED ATTIC COMPLETELY IN BUILDING ENVOLOPE IS
CONSIDERED A CONDITIONED SPACE NOT REQUIRED
8 EXTERIOR WALL OF
RETURN PLENUM
EXTERIOR WALL OF RETURN PLENUM. IN THIS CASE, THE CEILING SPACE IS
BEING USED AS A RETURN PLENUM. IT IS WITHIN THE BUILDING THERMAL
ENVELOPE. THEREFORE, THE EXTERIOR WALL MUST COMPLY WITH
INSULATION REQUIRMENTS IN IBC
SEE ARCHITECTURALS
9 SUPPLY OUTLET IN
PLENUM WITHIN BUILDING ENVELOPE AND EXTERIOR IS INSULATED NOT REQUIRED
10 SUPPLY RUNOUT IN
RETURN PLENUM
FLEX DUCT NOT REQUIRED TO BE INSULATED. HOWEVER, 1" OF INSULATION
IS NECESSARY FOR SOUND ATTENUATION AND AIR SEALING 1" OF INSULATION MIN.
11 SUPPLY IN RETURN
PLENUM
FOR SUPPLY DUCTS LOCATED WITHIN A RETURN PLENUM ITEMS 9, 10 AND 11
ARE ALL WITHIN AN INDIRECTLY HEATED SPACE. IN THAT REGARD THEY EACH
CAN BE UNINSULATED AS DISCUSSED IN ITEM 7
NOT REQUIRED
12 SUPPLY & RETURN IN
CONDITIONED SPACE
SUPPLY AND RETURN DUCTS OR PLENUMS LOCATED IN CONDITIONED SPACES
THEY SERVE DO NOT REQUIRE INSULATION. [SEE EXCEPTION 2 IF APPLIES]
TYPICAL SPACES N/R
KITCHENS R-6
NATATORIUM R-6
HIGH HUMIDIITY
SPACES R-6
13 SUPPLY & RETURN IN
VENTED CRAWL SPACE SIMILAR TO DUCTS IN VENTED ATTIC (SEE ITEM 3) R-6
14 BURIED SUPPLY LOCATED OUTSIDE OF THE BUILDING ENVELOPE [SEE EXCEPTION 2 IF APPLIES]
CLIMATE ZONE 1-4 R-8
CLIMATE ZONE 5 R-12
EXCEPTION 1:
DUCTS, PLENUMS AND CASINGS THAT ARE FACTORY INSTALLED AND AN INTEGRAL PART OF THE EQUIPMENT RATED IN ACCORDANCE WITH SECTION C403.3.2. AS FOR FACTORY-INSTALLED PIPING INSULATION, THIS EXCEPTION IS INTENDED TO APPLY TO CASINGS AROUND TESTED EQUIPMENT.
ALTHOUGH THEY ARE NOT ALWAYS INCLUDED IN PERFORMANCE TESTING, OPTIONAL CASINGS, SUCH AS ECONOMIZER SECTIONS, ALSO SHOULD BE EXEMPTED FROM INSULATION REQUIRMENTS IF THEY ARE INSULATED TO THE SAME EXTENT AS THE EQUIPMENT TO WHICH THEY ARE ATTACHED.
EXCEPTION 2:
EXHAUST AIR DUCTS AND DUCTS OR PLENUMS LOCATED ANYWHERE THE DESIGN TEMPERATURE DIFFERENCE BETWEEN THE AIR IN THE DUCT AND THE AIR SURROUNDING THE DUCT IS LESS THAN 15F. SIMPLY STATED, THIS INCLUDEDS DUCTS OR PLENUMS LOCATED IN THE CONDITIONED SPACE THEY SERVE - FOR EXAMPLE, EXHAUST DUCTS. THE DESIGNER SHOULD KEEP IN MIND THAT CERTAIN MINIMUM INSULATION LEVELS STILL MAY BE
REQUIRED TO PREVENT CONDENSATION.
Sheet No.
Drawn By
Reviewed ByDate
26 April 2024
Sheet Title
Pr oj ec t T itl e
Pr op os ed
A lte ra tio ns fo r:
N ob le
H ou se
Architect
S Br oa d
St re et N az ar et h, P A
NO. DATE ISSUE NOTE
REV. DATE DESCRIPTION
Project Manager
Project ID
St John_201 S Broad_Exist
All drawings and written materials appearing herein constitute original and unpublished work of the architect and may not be used or disclosed without prior consent of 4/4 Architecture, LLC
Copyrighted 2024
A 6/1/24 FOR REVIEW & COMMENT
B 1/26/26 FOR PRICING
HVAC
DETAILS
Reviewed ByDate
26 April 2024
Sheet Title
Pr oj ec t T itl e
Pr op os ed
A lte ra tio ns fo r:
N ob le
H ou se
Architect
S Br oa d
St re et N az ar et h, P A
NO. DATE ISSUE NOTE
REV. DATE DESCRIPTION
Project Manager
Project ID
St John_201 S Broad_Exist
All drawings and written materials appearing herein constitute original and unpublished work of the architect and may not be used or disclosed without prior consent of 4/4 Architecture, LLC
Copyrighted 2024
A 6/1/24 FOR REVIEW & COMMENT
B 1/26/26 FOR PRICING
SYMBOLS & LEGEND
SYMBOL DESCRIPTION MOUNTING
DUPLEX GROUNDED RECEPTACLE (NEMA 5-20R) 18" AFF
GROUND FAULT DUPLEX RECEPTACLE (NEMA 5-20R) 18" AFF
SPECIALTY RECEPTACLE (AS NOTED) 18" AFF
DISCONNECT SWITCH, (#AMP, #POLES, # NEMA
RATING) AS NOTED
JUNCTION BOX AS NOTED
SWITCHES (1-POLE) 20A, 120V 46" AFF
SWITCHES (3-WAY) 20A, 120V 46" AFF
SWITCHES (DIMMER) 20A, 120V 46" AFF
SWITCHES (OCCUPANT SENSOR) 20A, 120V 46" AFF
OCCUPANT SENSOR CEILING
EXHAUST FAN AS NOTED
COUNTER-TOP MOUNTED DEVICE 44" AFF
EXISTING DEVICE
WEATHERPROOF COVER WITH WEATHER RESISTANT
RECEPTACLE
UNDER COUNTER
HOME RUN (PHASE, PHASE, NEUTRAL, GROUND, #12
AWG U.N.O.) CEIL./WALL
BRANCH CIRCUIT PANEL & PANEL DESIG. 72" TO TOP
DUPLEX RECEPTACLE (NEMA 5-20R) W/ GFCI BREAKER 18" AFF
CEILING RECESSED DUPLEX RECEPTACLE ~44" AFF
GROUND FAULT DUPLEX RECEPTACLE (NEMA 5-20R) MICROWAVE
HEIGHT
Electrical Notes n
Drawn By
Reviewed ByDate
26 April 2024
Sheet Title
Pr oj ec t T itl e
Pr op os ed
A lte ra tio ns fo r:
N ob le
H ou se
Architect
S Br oa d
St re et N az ar et h, P A
NO. DATE ISSUE NOTE
REV. DATE DESCRIPTION
Project Manager
Project ID
St John_201 S Broad_Exist
All drawings and written materials appearing herein constitute original and unpublished work of the architect and may not be used or disclosed without prior consent of 4/4 Architecture, LLC
Copyrighted 2024
A 6/1/24 FOR REVIEW & COMMENT
B 1/26/26 FOR PRICING
Electrical Power Plan
FIRST FLOOR APARTMENT 'P.1'
MOUNTING VOLTAGE PHASE WIRE PANEL AIC RATING BUS CAPACITY (A) MAIN BREAKER (A) NO. OF CIRCUITS LOCATION
SURFACE 240 / 120 1 3 MATCH EX. 100 70 24 BASE
CKT # DESCRIPTION LOAD
TYPE
LOAD
AMPS
LOAD
VA
CONDUCTORS GND
SIZE
COND
SIZE
BKR
A/P
PHASE BKR
A/P
COND
SIZE
GND
SIZE
CONDUCTORS LOAD
VA
LOAD
AMPS
LOAD
TYPE DESCRIPTION CKT #
QTY SIZE A B SIZE QTY
CONDENSING UNIT C-1
AC 14.4 1728
2 #10 #10 3/4" 25/2
2784 15/1 GFCI MC #12 #12 2 1056 8.8 AC FURN-1 2
3 AC 14.4 1728 1848 15/1 GFCI MC #12 #12 2 120 1 AC CC-1 4
5 WATER HEATER WH 2 240 2 #12 #12 MC 20/1 GFCI
AFCI 840 20/1 AFCI MC #12 #12 2 600 5 L LIGHTING AND FAN 6
7 KITCHEN - MICROWAVE K 5 600 2 #12 #12 MC 20/1 GFCI
AFCI 960 20/1 AFCI MC #12 #12 2 360 3 R KITCHEN COUNTER RECEPS 8
9 KTICHEN - FRIDGE K 5 600 2 #12 #12 MC 20/1 GFCI
AFCI 960 20/1 AFCI MC #12 #12 2 360 3 R KITCHEN COUNTER RECEPS 10
11 DINING RECEPS R 7.5 900 2 #12 #12 MC 20/1 AFCI 1080 20/1 MC #12 #12 2 180 1.5 R BATHROOM RECP 12
13 BEDROOM RECEPS R 9 1080 2 #12 #12 MC 20/1 AFCI 1200 20/1 GFCI
AFCI MC #12 #12 2 120 1 K GAS STOVE 14
15 LIVING ROOM RECEPS R 10.5 1260 2 #12 #12 MC 20/1 AFCI 1620 20/1 GFCI
AFCI MC #12 #12 2 360 3 K DISHWASHER 16
17 BEDROOM RECEPS R 9 1080 2 #12 #12 MC 20/1 AFCI 1080 18
19 0 20 21 0 22 23 0 24
TOTAL CONNECTED LOAD (VA) A,B
TOTAL CONNECTED LOAD (AMPS) A,B
6864 5508 KVA WITH DIVERSITY APPLIED
AMPS WITH DIVERSITY APPLIED
12.4 KVA
57.2 45.9 51.55 AMPS
L = LIGHTING
R= RECEPTACLE
AC = AIR CONDITIONING
EH = ELECTRIC HEAT
M = MOTOR
K= KITCHEN
WH = WATER HEATER
N = NON LINEAR
SL = SITE LIGHTING
NL = NO LOAD
FIRST FLOOR APARTMENT 'P.2'
MOUNTING VOLTAGE PHASE WIRE PANEL AIC RATING BUS CAPACITY (A) MAIN BREAKER (A) NO. OF CIRCUITS LOCATION
RECESSED 240 / 120 1 3 MATCH EX. 100 70 24 2ND FLR
CKT # DESCRIPTION LOAD
TYPE
LOAD
AMPS
LOAD
VA
CONDUCTORS GND
SIZE
COND
SIZE
BKR
A/P
PHASE BKR
A/P
COND
SIZE
GND
SIZE
CONDUCTORS LOAD
VA
LOAD
AMPS
LOAD
TYPE DESCRIPTION CKT #
QTY SIZE A B SIZE QTY
CONDENSING UNIT C-1
AC 14.4 1728
2 #10 #10 3/4" 25/2
2784 15/1 GFCI MC #12 #12 2 1056 8.8 AC FURN-1 2
3 AC 14.4 1728 1848 15/1 GFCI MC #12 #12 2 120 1 AC CC-1 4
5 WATER HEATER WH 2 240 2 #12 #12 MC 20/1 GFCI
AFCI 840 20/1 AFCI MC #12 #12 2 600 5 L LIGHTING AND FAN 6
7 KITCHEN - MICROWAVE K 5 600 2 #12 #12 MC 20/1 GFCI
AFCI 960 20/1 AFCI MC #12 #12 2 360 3 R KITCHEN COUNTER RECEPS 8
9 KTICHEN - FRIDGE K 5 600 2 #12 #12 MC 20/1 GFCI
AFCI 960 20/1 AFCI MC #12 #12 2 360 3 R KITCHEN COUNTER RECEPS 10
11 DINING RECEPS R 10.5 1260 2 #12 #12 MC 20/1 AFCI 1440 20/1 MC #12 #12 2 180 1.5 R BATHROOM RECP 12
13 BEDROOM RECEPS R 12 1440 2 #12 #12 MC 20/1 AFCI 1560 20/1 GFCI
AFCI MC #12 #12 2 120 1 K GAS STOVE 14
15 LIVING ROOM RECEPS R 13.5 1620 2 #12 #12 MC 20/1 AFCI 1980 20/1 GFCI
AFCI MC #12 #12 2 360 3 K DISHWASHER 16
17 ENTRANCE RECEPS R 7.5 900 2 #12 #12 MC 20/1 AFCI 900 18
19 0 20 21 0 22 23 0 24
TOTAL CONNECTED LOAD (VA) A,B
TOTAL CONNECTED LOAD (AMPS) A,B
7044 6228 KVA WITH DIVERSITY APPLIED
AMPS WITH DIVERSITY APPLIED
13.3 KVA
58.7 51.9 55.30 AMPS
L = LIGHTING
R= RECEPTACLE
AC = AIR CONDITIONING
EH = ELECTRIC HEAT
M = MOTOR
K= KITCHEN
WH = WATER HEATER
N = NON LINEAR
SL = SITE LIGHTING
NL = NO LOAD
HOUSE PANEL 'P.H'
MOUNTING VOLTAGE PHASE WIRE PANEL AIC RATING BUS CAPACITY (A) MAIN BREAKER (A) NO. OF CIRCUITS LOCATION
SURFACE 240 / 120 1 3 MATCH EX. 100 60 24 BASE
CKT # DESCRIPTION LOAD
TYPE
LOAD
AMPS
LOAD
VA
CONDUCTORS GND
SIZE
COND
SIZE
BKR
A/P
PHASE BKR
A/P
COND
SIZE
GND
SIZE
CONDUCTORS LOAD
VA
LOAD
AMPS
LOAD
TYPE DESCRIPTION CKT #
QTY SIZE A B SIZE QTY
1 EXISTING BASEMENT LIGHTS L 5 600 2 #12 #12 MC 20/1 AFCI 600 2
3 EXISTING BASEMENT RECEPTACLES R 5 600 2 #12 #12 MC 20/1 AFCI 600 4
5 GARAGE MISC POWER R 5 600 2 #12 #12 MC 20/1 AFCI 600 6
7 EXTERIOR MISC RECEP R 5 600 2 #12 #12 MC 20/1 AFCI 600 8
BASEMENT 2KW HEATER
EH 8.3 996
2 #12 #12 MC 20/2
996 10
11 EH 8.3 996 996 12
13 0 14 15 0 16 17 0 18 19 0 20 21 0 22 23 0 24
TOTAL CONNECTED LOAD (VA) A,B
TOTAL CONNECTED LOAD (AMPS) A,B
2196 2196 KVA WITH DIVERSITY APPLIED
AMPS WITH DIVERSITY APPLIED
4.4 KVA
18.3 18.3 18.30 AMPS
Drawn By
Reviewed ByDate
26 April 2024
Sheet Title
Pr oj ec t T itl e
Pr op os ed
A lte ra tio ns fo r:
N ob le
H ou se
Architect
S Br oa d
St re et N az ar et h, P A
NO. DATE ISSUE NOTE
REV. DATE DESCRIPTION
Project Manager
Project ID
St John_201 S Broad_Exist
All drawings and written materials appearing herein constitute original and unpublished work of the architect and may not be used or disclosed without prior consent of 4/4 Architecture, LLC
Copyrighted 2024
A 6/1/24 FOR REVIEW & COMMENT
B 1/26/26 FOR PRICING
Electrical Lighting Plan
BONDING AND GROUNDING
ELECTRODE SIZES - 200A
DESCRIPTION
MAIN BONDING JUMPER
SUPPLY-SIDE BONDING JUMPER
SIZE
#4
TYPE
AWG Cu
#4
CODE
NEC 250.102(C)(1)
AWG Cu NEC 250.102(C)(1)
BONDING JUMPER'S #4 AWG Cu NEC 250.66
*SIZED OFF LARGEST UNGROUNDED CONDUCTOR
*REFER TO NEC FOR ALL EXCEPTIONS AND SPECIFICATIONS
** TBD BASE OFF SUPPLY CONDUCTORS PROVIDED BY PPL
Sheet No.
Drawn By
Reviewed ByDate
26 April 2024
Sheet Title
Pr oj ec t T itl e
Pr op os ed
A lte ra tio ns fo r:
N ob le
H ou se
Architect
S Br oa d
St re et N az ar et h, P A
NO. DATE ISSUE NOTE
REV. DATE DESCRIPTION
Project Manager
Project ID
St John_201 S Broad_Exist
All drawings and written materials appearing herein constitute original and unpublished work of the architect and may not be used or disclosed without prior consent of 4/4 Architecture, LLC
Copyrighted 2024
A 6/1/24 FOR REVIEW & COMMENT
B 1/26/26 FOR PRICING
Electrical Details
Reviewed ByDate
26 April 2024
Sheet Title
Pr oj ec t T itl e
Pr op os ed
A lte ra tio ns fo r:
N ob le
H ou se
Architect
S Br oa d
St re et N az ar et h, P A
NO. DATE ISSUE NOTE
REV. DATE DESCRIPTION
Project Manager
Project ID
St John_201 S Broad_Exist
All drawings and written materials appearing herein constitute original and unpublished work of the architect and may not be used or disclosed without prior consent of 4/4 Architecture, LLC
Copyrighted 2024
A 6/1/24 FOR REVIEW & COMMENT
B 1/26/26 FOR PRICING
Plumbing Notes
SYMBOLS & LEGEND
SYMBOL DESCRIPTION
Drawn By
Reviewed ByDate
26 April 2024
Sheet Title
Pr oj ec t T itl e
Pr op os ed
A lte ra tio ns fo r:
N ob le
H ou se
Architect
S Br oa d
St re et N az ar et h, P A
NO. DATE ISSUE NOTE
REV. DATE DESCRIPTION
Project Manager
Project ID
St John_201 S Broad_Exist
All drawings and written materials appearing herein constitute original and unpublished work of the architect and may not be used or disclosed without prior consent of 4/4 Architecture, LLC
Copyrighted 2024
A 6/1/24 FOR REVIEW & COMMENT
B 1/26/26 FOR PRICING
Sanitary Piping Plans
PLUMBING PIPE INSULATION SCHEDULE
SYSTEM / SERVICE
⁰
INSULATION THICKNESS (IN)
MINERAL-FIBER INSULATION FLEXIBLE ELASTOMERIC INSULATION
NORMINAL PIPE SIZE (IN) NOMINAL PIPE SIZE (IN)
LESS THAN 1" 1" TO 1 1/4" 1 1/2" TO 4" 4" TO 8" 8" OR LARGER LESS THAN 1" 1" TO 1 1/4" 1 1/2" TO 4" 4" TO 8" 8" OR LARGER
POTABLE COLD WATER 40°F - 60°F 1/2 1/2 1 1 1 1/2 1/2 1 1 1
POTABLE HOT WATER,
HOT WATER RETURN 105°F - 140°F 1 1 1 1/2 1 1/2 1 1/2 3/4 3/4 1 1 1
STORM WATER
LEADERS
(HORIZONTAL PIPE
ONLY)
N/A 1 1 1 1 1 1 1 1 1 1
POTABLE WATER, SANITARY & VENT SUPPORT SPACING
MATERIAL
NOMINAL PIPE SIZE
3/8 1/2 3/4 1 1 1/2 2 2 1/2 3 & LARGER
COPPER OR COPPER
ALLOY TUBING 5 FT 5 FT 5 FT 6 FT 8 FT 8 FT 9 FT 10 FT
COPPER OR COPPER
ALLOY PIPE 12 FT 12 FT 12 FT 12 FT 12 FT 12 FT 12 FT 12 FT
SCH. 40 STEEL PIPE 7 FT 7 FT 7 FT 7 FT 9 FT 10 FT 11 FT 12 FT
PVC DWV 4 FT 4 FT 4 FT 4 FT 4 FT 4 FT 4 FT 4 FT
NOTE:
SPACINGS LISTED ARE MAXIMUM ALLOWABLE IN THE HORIZONTAL POSITION.
MAXIMUM ALLOWABLE SPACINGS IN THE VERTICAL POSITION SHALL BE AS FOLLOWS:
• COPPER OR COPPER ALLOY TUBING OR PIPE - 10 FT
• STEEL PIPE - 15 FT
• PVC PIPE - 10 FT; MIDSTORY GUIDES FOR SIZES 2" AND SMALLER ARE REQUIRED
PLUMBING FIXTURE SCHEDULE
SYMBOL DESCRIPTION
FIXTURE FITTING PIPE SIZES (INCHES) RIM HEIGHT
(INCHES) REMARKS
MANUFACTURER MODEL MANUFACTURER MODEL CW HW W V
WC1 TOILET AMERICAN
STANDARD 3517D101.020 AMERICAN
STANDARD 4188A004.020 3/4" --- 4" 2" FINAL SELECTION TO BE CONFIRMED BY OWNER.
L1 LAVATORY HOROW CBS-S03 KINGSTON KB1972AX 1/2" 1/2" 1 1/2" 1 1/2" FINAL SELECTION TO BE CONFIRMED BY OWNER. 2"
MIN BELOW GRADE FOR WASTE AND VENTS.
B1 BATH AMERICAN
STANDARD 2390202.02 KINGSTON KB23.PL 1/2" 1/2" 2" 1 1/2" FINAL SELECTION TO BE CONFIRMED BY OWNER. 2"
MIN BELOW GRADE FOR WASTE AND VENTS
KS1 KITCHEN SINK KOHLER K-4H28176-1-NA AMERICAN
STANDARD 7418300-075 1/2" 1/2" 2" 1 1/2" FINAL SELECTION TO BE CONFIRMED BY OWNER.
Drawn By
Reviewed ByDate
26 April 2024
Sheet Title
Pr oj ec t T itl e
Pr op os ed
A lte ra tio ns fo r:
N ob le
H ou se
Architect
S Br oa d
St re et N az ar et h, P A
NO. DATE ISSUE NOTE
REV. DATE DESCRIPTION
Project Manager
Project ID
St John_201 S Broad_Exist
All drawings and written materials appearing herein constitute original and unpublished work of the architect and may not be used or disclosed without prior consent of 4/4 Architecture, LLC
Copyrighted 2024
A 6/1/24 FOR REVIEW & COMMENT
B 1/26/26 FOR PRICING
Potable Water Piping Plans
Drawn By
Reviewed ByDate
26 April 2024
Sheet Title
Pr oj ec t T itl e
Pr op os ed
A lte ra tio ns fo r:
N ob le
H ou se
Architect
S Br oa d
St re et N az ar et h, P A
NO. DATE ISSUE NOTE
REV. DATE DESCRIPTION
Project Manager
Project ID
St John_201 S Broad_Exist
All drawings and written materials appearing herein constitute original and unpublished work of the architect and may not be used or disclosed without prior consent of 4/4 Architecture, LLC
Copyrighted 2024
A 6/1/24 FOR REVIEW & COMMENT
B 1/26/26 FOR PRICING
Natural Gas Piping Plans
| A0.1-Building Code Data, Site Plan & Compartmentation |
| 2/Ex-6 |
| Viewport-3 |
| Viewport-4 |
| Viewport-5 |
| Section-3 |
| D1.1-Basement, First & Second Floor Demolition Plan |
| 1/Ex-14 |
| 1/Ex-15 |
| 1/Ex-16 |
| A1.1-Basement, First & Second Floor Plan, Finish Specifications |
| 4/A1.1 |
| 1/Ex-9 |
| 1st floor plan |
| 1/Ex-13 |
| A2.1-Exterior Elevations |
| 3/A2.1 |
| 3/A2.2 |
| 3/A2.3 |
| 3/A2.4 |
| A3.1-Enlarged Plans & Interior Elevations |
| second floor kitchen-2 |
| second floor bath |
| second floor bath-2 |
| A/A3.1 |
| first floor bath-3 |
| first floor bath-4 |
| Viewport-1 |
| Viewport-2 |
| Section-1 |
| Section-2 |
| second floor kitchen |
| B/A3.1 |
| A4.1-Door Schedule, Floor/ Ceiling & Partition Types |
| 1/A4.1 |
| 1/A4.2 |