This Addendum 1 document modifies the contract drawings for renovations to the Noble House at 201 South Broad Street, Nazareth, Pennsylvania, a project by St. John's United Church of Christ. Issued on March 3, 2026, the addendum replaces the original exterior elevations sheet dated February 26, 2026 with an updated version. The project involves converting an existing single-family dwelling into two individual dwelling units through selective demolition and associated general, mechanical, electrical, and plumbing construction. Sealed bids were due online via the PennBid Program on March 31, 2026 at 10:00 A.M., with a pre-bid meeting held on March 12, 2026 at the project site. Contract documents became available online beginning February 26, 2026 at 9:00 A.M. at no cost.
The exterior elevations specified in Addendum 1 detail comprehensive work across all four elevations of the structure, including replacement of rotted wood soffits, membrane roof installation over the front porch with new copper flashing, installation of new sconce lighting, power washing of existing siding, corner trim repairs, roofing replacement (both membrane and asphalt shingle), window replacements with Harvey brand vinyl windows featuring low-e glass and Energy Star compliance, safety glazing at bathroom windows, and infilling of a former vent opening. Bidders were required to provide a 5 percent bid bond, with the successful contractor furnishing performance and payment bonds each equal to 100 percent of the total contract value. The project is subject to Davis-Bacon Act prevailing wage requirements, and the work encompasses four prime contracts: General Construction, Mechanical Construction, Electrical Construction, and Plumbing Construction.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Addendum 1 (2 pages)
For
Noble House St. John’s United Church of Christ
Nazareth, PA 1864
Date: March 3, 2026
1. Sheet A2.1 EXTERIOR ELEVATIONS, DATED BID SET 02/26/2026 shall be replaced with Sheet A2.1 EXTERIOR ELEVATIONS, DATED 3/3/2026 ADDENDUM 1. (1 Page)
Sheet No.
Drawn By
Reviewed ByDate
A2.1
GaL
GaL26 April 2024
Sheet Title
P ro je ct
T itl e
Exterior Elevations
Pr op os ed
A lte ra tio ns fo r:
N ob le
H ou se
Architect
S B ro ad
S tre et N az ar et h, P A
NO. DATE ISSUE NOTE
REV. DATE DESCRIPTION
Project Manager
GaL
Project ID
St John_201 S Broad_Exist
All drawings and written materials appearing herein constitute original and unpublished work of the architect and may not be used or disclosed without prior consent of
4/4 Architecture, LLC Copyrighted 2024
1 3/3/26 Addendum #1
1 7/3/24 For Permit
West (Front) Elevation Scale: 1/8" = 1'-0"
Patch & repair rotted wood soffit, paint to match existing
Replace exist.
membrane roof over front porch. Provide & install new copper flashing, reget into brick joint
South (Side) Elevation Scale: 1/8" = 1'-0"
New sconce lighting, see electrical dwg's
Typ. for all new replacement windows:
Install coil stock over exist. sill & trim to match new windows and seal
Power wash exist.
siding
Repair corner trim
Remove exist.
roofing & install new membrane roof
Remove exist. asphalt shingle roofing & install new asphalt shingle roof
Install new copper flashing, reglet into brick joint above previous installation
W-3
W-4
W-1 W-1
W-4
East (Rear) Elevation Scale: 1/8" = 1'-0"
Infill former vent opening w/ brick to match exist.
W-3
North (Side) Elevation Scale: 1/8" = 1'-0"
Typ. for all new replacement windows:
Install coil stock over exist. sill & trim to match new windows and seal
W-1 W-2W-2
W-3
W-4W-4
W-3 W-3
At bathroom window, provide safety glazing. Install translucent film over lower sash as selected by architect
Window Types
1' -4
E x is t.
2'-4 3/4"
W-1
E x is t.
2'-0"
W-2
E x is t.
2'-7"
W-3
1'-11"
W-4
Sliding basement window Operable double hung
Operable double hung
Operable double hung
Specification for replacement windows:
Provide and install vinyl windows as manufactured by 'Harvey' with insulated, low-e glass to meet Energy Star requirements. Provide w/ divided lites within glass to match exist. Window units to be complete with insect screens and locking hardware. Color:
white
Simulated divided lite
(between glass) to match exist., typ.