2-EXHIBIT A - Safford House Bid Drawings.pdf
PDF 2 MB Posted
- Attached to
- Historical Safford House Roof Replacement
- Solicitation number
- 260104-B-AS
- Issued by
- Pinellas County, Florida
About this file
This is a bid drawing set for the City of Tarpon Springs Public Services Department, Recreation Division, for the Safford House and Accessory Building roof replacement project located at 23 Parkins Court, Tarpon Springs, Florida 34689 (Project No. 400801039). The project scope includes removal of existing roofing systems and installation of new roofing systems including cedar shake shingles on steep-sloped sections, low-slope roofing membrane assemblies on sections with pitch less than 3:12, new aluminum flashing at all penetrations and transitions, new aluminum crickets at chimneys, new aluminum drip edge at rakes and eaves, repair of deteriorated wood plank decking with in-kind materials, installation of new plywood decking over original plank decking, and replacement of galvanized roof vents with aluminum gooseneck vents. The work must adhere to the Secretary of Interior Standards for Historic Preservation Rehabilitation Guidelines and comply with local building codes. The bid set includes a cover sheet, demolition plan, construction plan with five detailed sections covering ridge, valley, vent pipe, and chimney flashing installations, with all specifications and dimensions clearly marked on the drawings issued June 19, 2026.
The project architect is Stantec Consulting Services Inc., located in Atlanta, Georgia, and the project engineer is the City of Tarpon Springs Public Services Department. Bidders must obtain all required permits within local jurisdiction, coordinate staging areas with the owner, and haul away all debris. Cedar shake shingles must match existing shingles in kind, including material species, dimensions, details, and exposure, and be installed in accordance with the Cedar Shake and Shingle Bureau New Roof Construction Manual, 2025 Edition. All materials specified are provided with approved equal alternatives, including underlayment, ventilation mats, flashing materials, and roofing membrane products. The drawings provide for pricing purposes only, and bidders are instructed to notify the owner if existing conditions differ from those outlined in the documents.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CITY OF TARPON SPRINGS
PUBLIC SERVICES DEPARTMENT - RECREATION DIVISION
324 EAST PINE STREET
TARPON SPRINGS, FL 34689
SHEET NO. TITLE
SAFFORD HOUSE AND
ACCESSORY BUILDING
ROOF REPLACEMENT
23 PARKINS CT
TARPON SPRINGS, FL 34689
PROJECT NO. 400801039
ISSUED: 06/19/2026
LOCATION MAP
ARCHITECT
OWNER
SITE MAP
GI-001 COVER SHEET
CS-101 DEMOLITION PLAN
CS-102 CONSTRUCTION PLAN AND DETAILS
S A
F F
O R
D H
O U
S E
A
C C
E S
S O
R Y
B U
IL
D
IN
G
R O
O F
R E
P
LA
C E
M E
N T
STATUS : BID SET
PROJECT ENGINEER PROJECT ARCHITECT
STANTEC CONSULTING SERVICES INC.
100 PEACHTREE STREET NW, MEZZANINE
ATLANTA, GA 30303
324 EAST PINE STREET
TARPON SPRINGS, FL 34689
BOARD OF COMMISSIONERS:
JOHN KOULIANOS, MAYOR
MICHAEL EISNER, VICE MAYOR
PANAGIOTIS (PETER) KOULIAS
FRANK DIDONATO
DAVID BANTHER
THOMAS F. BURKE CARA SOH
06/19/2026
400801039
READ ST
PARKINS CT
G R
A N
D B
LV
D
N
N
3/16" = 1'-0"CS-101
1 DEMOLITION PLAN
Client/Project
Dwn. Chkd. Dsgn.MM.DD.YY
File Name:
Consultants
Stantec Consulting Services Inc.
100 Peachtree St NW, Mezzanine
Atlanta, GA 30303 www.stantec.com
TEL 404.524.2200
DEMOLITION PLAN
PLAN
CS-101
3/16" = 1'-0"
400801039
EXISTING MASONRY CHIMNEY
FLUE TO REMAIN. REMOVE
FLASHING AT CHIMNEY AND
CRICKET, TYPICAL
REMOVE EXISTING SHINGLE
AND UNDERLAYMENT DOWN TO
EXISTING ROOF DECK, TYPICAL
GUTTERS AND LEADERS TO
REMAIN. PROVIDE PROTECTION,
TYPICAL
WOOD TRIM AND RAFTERS TO
REMAIN. PROVIDE
PROTECTION, TYPICAL
LOW SLOPED ROOF, V.I.F.
EXISTING VENT TO REMAIN. REMOVE
FLASHING, TYPICAL
REMOVE EXISTING SHINGLE AND
UNDERLAYMENT DOWN TO EXISTING ROOF
DECK, TYPICAL
GUTTERS AND LEADERS TO REMAIN.
PROVIDE PROTECTION, TYPICAL
WOOD TRIM AND RAFTERS TO REMAIN.
PROVIDE PROTECTION, TYPICAL
LOW SLOPED ROOF, V.I.F.
REMOVE EXISTING ROOFIING MEMBRANE
DOWN TO EXISTING ROOF DECK
LINE OF BUILDING ENVELOPE
BELOW
LINE OF BUILDING ENVELOPE BELOW
67'-1"
21'-2"
22'-1"
REMOVE EXISTING ROOFIING
MEMBRANE DOWN TO EXISTING
WOOD PLANK DECKING
REMOVE EXISTING ROOF SHINGLE
ASSEMBLY DOWN TO ROOF DECK
REMOVE EXISTING ROOF
MEMBRANE/SHEATHING ASSEMBLY
DOWN TO ROOF DECK
LINE OF BUILDING ENVELOPE
BELOW
DOWN DIRECTION OF ROOF SLOPE
GRAPHIC KEY
GENERAL DEMOLITION NOTES
1. OBTAIN ALL REQUIRED PERMITS WITHIN THE LOCAL
JURISDICTION.
2. COORDINATE STAGING AREA WITH OWNER.
3. CLEAN AND HAUL AWAY ALL DEBRIS.
4. ADHERE TO THE SECRETARY OF INTERIORS STANDARDS FOR
HISTORIC PRESERVATION REHABILITATION GUIDELINES.
5. REMOVE ALL EXISTING FLASHING AT ROOF PENETRATIONS
INCLUDING VENTILATION PIPES, DUCTS, AND CHIMNEY.
6. REMOVE EXISTING ROOF ASSEMBLY DOWN TO ORIGINAL PLANK
WOOD DECKING.
7. REPAIR DETERIORATED WOOD PLANK DECKING WITH IN KIND
MATERIAL AND FASTENERS.
8. VERIFY ALL ROOF TYPES, SLOPES, AND DIMENSIONS.
INFORMATION PROVIDED ON THE DRAWINGS ARE FOR PRICING
PURPOSES ONLY. NOTIFY OWNER IF EXISTING CONDITIONS ARE
DIFFERENT FROM WHAT IS OUTLINED IN THE DOCUMENTS.
3/16" = 1'-0"A-100
1 CONSTRUCTION PLAN
Client/Project
Dwn. Chkd. Dsgn.MM.DD.YY
File Name:
Consultants
Stantec Consulting Services Inc.
100 Peachtree St NW, Mezzanine
Atlanta, GA 30303 www.stantec.com
TEL 404.524.2200
CONSTRUCTION PLAN
AND DETAILS
CS-102
AS NOTED
400801039
14'-4" 6'-9"
22'-1"10'-7"
12'-5"
12'-5"
17'-5" 10' 16'-11"
INSTALL ALUMINUM CRICKET. MATCH
PROFILE AND DETAIL OF THE
EXISTING. REPAIR SUBSTRUCTURE IF
DAMAGED.
INSTALL BULLET BOOT FLASHING AT VENT.
SEE DETAIL 4 FOR SIMILAR INSTALLATION
INSTALL ALUMINUM FLASHING AT MASONRY
CHIMNEY, SEE DETAIL 5
INSTALL ALUMINUM CRICKET AT MASONRY
CHIMNEY. MATCH PROFILE AND DETAIL OF THE
EXISTING. REPAIR SUBSTRUCTURE IF
DAMAGED.
INSTALL ALUMINUM CRICKET AT
MASONRY CHIMNEY. MATCH
PROFILE AND DETAIL OF THE
EXISTING. REPAIR SUBSTRUCTURE
IF DAMAGED.
INSTALL ALUMINUM FLASHING
AT MASONRY CHIMNEY, SEE
DETAIL 5
11'-5" 44'-4" 11'-5"
16'-6" 11'-4" 16'-6"
INSTALL CEDAR SHAKE CAPS
AT RIDGE AND HIP, TYP. SEE
DETAIL 3
INSTALL POLYGLASS SELF-ADHERED
BASE SHEET WIT POLYFRESKO CAP
SHEET OVER UNDERLAYMENT AND
PLYWOOD SHEATHING AT ROOF SLOPES
LESS THAN 3:12 PITCH, TYPICAL
INSTALL CEDAR SHAKE SHINGLES
OVER VENTILATION MAT, SELF
ADHERED UNDERLAYMENT, AND
PLYWOOD SHEATHING ON TOP OF
EXISTING PLANK DECKING, TYPICAL.
SEE DETAILS
INSTALL POLYGLASS SELF-ADHERED BASE
SHEET WIT POLYFRESKO CAP SHEET OVER
UNDERLAYMENT AND PLYWOOD
SHEATHING AT ROOF SLOPES LESS THAN
3:12 PITCH, TYPICAL
INSTALL CEDAR SHAKE CAPS AT RIDGE
AND HIP, TYP. SEE DETAIL 3
INSTALL CEDAR SHAKE SHINGLES OVER
VENTILATION MAT, SELF ADHERED
UNDERLAYMENT, AND PLYWOOD
SHEATHING ON TOP OF EXISTING PLANK
DECKING, TYPICAL. SEE DETAILS
1" = 1'-0"CS-102
3 RIDGE DETAIL
BENJAMIN OBDYKE CEDAR
BREATHER VENTILATION MAT OR
APPROVED EQUAL
EXISTING 2X RAFTER
EXISTING PLANK DECKING
PLYWOOD SHEATHING
OWENS CORNING TITANIUM PSU-30
SELF ADHERED UNDERLAYMENT OR
APPROVED EQUAL
FOLD #30LB FELT UNDERLAYMENT
OVER TOP COURSE OF SHAKE
SHINGLE
MAINTAIN 2" MIN. SLOT AT RIDGE
BENJAMIN OBDYKE RAPID
RIDGE VENT OR
APPROVED EQUAL
OWENS CORNING TITANIUM
PSU-30 SELF ADHERED
UNDERLAYMENT OR
APPROVED EQUAL
CEDAR SHAKE RIDGE CAP
OVERLAPPING CEDAR
SHAKE RIDGE CAP BEYOND
CS-102
2 VALLEY DETAIL
BENJAMIN OBDYKE CEDAR
BREATHER VENTILATION MAT OR
APPROVED EQUAL
EXISTING 2X RAFTER
EXISTING PLANK DECKING
PLYWOOD SHEATHING
OWENS CORNING TITANIUM PSU-30
SELF ADHERED UNDERLAYMENT OR
APPROVED EQUAL
24" WIDE OWENS CORNING
TITANIUM PSU-30 SELF ADHERED
UNDERLAYMENT OR APPROVED
EQUAL
CENTER CRIMPED
.032 ALUMINUM
VALLEY FLASHING
CEDAR SHAKE
SHINGLE
CS-102
5 CHIMNEY FLASHING DETAIL
1 " = 1'-0"1" = 1'-0"
EXISTING 2X RAFTER
BENJAMIN OBDYKE CEDAR
BREATHER VENTILATION MAT OR
APPROVED EQUAL
EXISTING PLANK DECKING
PLYWOOD SHEATHING
CEDAR SHAKE SHINGLE. MAINTAIN
1" MIN. CLEARANCE AROUND
VERTICAL SURFACES.
STEP AND OVERLAP .032
ALUMINUM APRON FLASHING
AROUND MASONRY CHIMNEY.
OVERLAP DOWNSLOPE FLASHING
OVER SHAKE SHINGLE COURSE.
CS-102
4 VENT PIPE FLASHING DETAIL
1" = 1'-0"
M
IN
EXISTING 2X RAFTER
BENJAMIN OBDYKE CEDAR
BREATHER VENTILATION MAT OR
APPROVED EQUAL
EXISTING PLANK DECKING
PLYWOOD SHEATHING
OWENS CORNING TITANIUM PSU-30
SELF ADHERED UNDERLAYMENT
OR APPROVED EQUAL
CEDAR SHAKE SHINGLE. MAINTAIN 1"
CLEARANCE UPSLOPE AND PARALELL
TO VERTICAL PENETRATION
BULLET BOOT PIPE FLASHING OR
APPROVED EQUAL. OVERLAP
DOWNSLOPE FLASHING OVER SHAKE
SHINGLE COURSE
EXISTING PLUMBING VENT
MAINTAIN 1/2" RIDGE CAP
OVERHANG OVER RIDGE VENT
MAINTAIN CLEARANCE
AT VALLEY IN
COMPLIANCE WITH
LOCAL JURISDICTION
OWENS CORNING TITANIUM PSU-30
SELF ADHERED UNDERLAYMENT OR
APPROVED EQUAL
INSTALL CEDAR SHINGLE
INSTALL ROOFING MEMBRANE FOR
SLOPES LESS THAN 3:12
INSTALL CEDAR RIDGE/HIP CAP
LINE OF BUILDING ENVELOPE
BELOW
DOWN DIRECTION OF ROOF SLOPE
GRAPHIC KEY
GENERAL CONSTRUCTION NOTES
1. EXECUTE ALL NEW CONSTRUCTION WORK IN COMPLIANCE WITH LOCAL BUILDING CODE
REQUIREMENTS AND AUTHORITIES HAVING JURISDICTION.
2. INSTALL NEW SOLID PLYWOOD DECKING OVER ORIGINAL PLANK WOOD DECKING WITH 8D
RING SHANK NAILS.
3. AT ROOF SLOPE TRANSITIONS BETWEEN CEDAR SHAKE AND LOW SLOPE ROOF
ASSEMBLIES (LESS THAN 3:12 SLOPE), INSTALL .032 ALUMINUM FLASHING ACCORDING TO
MANUFACTURERS' INSTRUCTIONS.
4. INSTALL CONTINUOUS .032 ALUMINUM DRIP EDGE AT ALL ROOF RAKES AND EAVES AND
FASTEN WITH STAINLESS STEEL RING SHANK NAILS.
5. IDENTIFY ALL ROOF PENETRATIONS INCLUDING VENTILATION PIPES, DUCTWORK,
ANTENNAS, AND CHIMNEYS AND INSTALL FLASHING.
6. REPLACE EXISTING GALVANIZED ROOF VENTS WITH .032 ALUMINUM GOOSENECK ROOF
VENTS AND ASSOCIATED FLASHING.
7. REMOVE AND REINSTALL WOOD SIDING AND TRIM WHEN REPAIRING FLASHING AT
VERTICAL SURFACES. PREP AND PAINT WOOD TO MATCH EXISTING.
8. INSTALL CEDAR SHAKE SHINGLES TO MATCH THE EXISTING SHINGLES IN KIND INCLUDING
MATERIAL SPECIES, DIMENSIONS, DETAILS, AND EXPOSURE. INSTALL CEDAR SHAKE
SHINGLES WITH STAINLESS STEEL NAILS.
9. INSTALL CEDAR SHAKE SHINGLES IN ACCORDANCE WITH THE CEDAR SHAKE AND
SHINGLE BUREAU, NEW ROOF CONSTRUCTION MANUAL, 2025 EDITION.
10. INSTALL ALL PRODUCTS ACCORDING TO MANUFACTURER'S INSTRUCTIONS.
11. INSTALL SELF-ADHERED MEMBRANE ASSEMBLY AT ROOF SLOPE WITH A PITCH LESS
THAN 3:12.