This document provides specifications for a metal building system for a watercraft aquatic nuisance species decontamination facility at Ridgway Reservoir in Colorado. The facility will require a 26 gauge steel sheet stock for the wall system with an earth-tone tan finish. Roof insulation will have an R-value of at least R-20 and wall insulation an R-value of at least R-13. Interior finish will be white with gutters, downspouts, and other accessories to match. Steel doors and frames will conform to specification 08 11 10. The solicitation number is 140R4022R0018 from the Department of the Interior Bureau of Reclamation for an ANS decontamination facility at Ridgway Reservoir, Colorado.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Watercraft ANS Decontamination Facility at Ridgway Reservoir .

Metal Building System

13 34 20 - 6

B. Interior Finish: Manufacturer’s standard factory-applied backer coating.

1. Color: White.

C. Roof insulation: Batt glass fiber type, faced with reinforced white vinyl.

D. Thermal Resistance Value: R value of R-20 or greater when tested in accordance with

ASTM C1363.

2.07 WALL SYSTEM

A. Sheet Steel Stock:

1. ASTM A 792, Structural Steel (SS), Grade 80, Coating Designation AZ55.

2. Thickness: 26 gauge, minimum.

3. Profile: Submitted and approved by COR.

4. Finish: Manufacturer’s exterior grade, factory-applied, oven-cured, 70-percent polyvinylidene-fluoride or silicone-polyester finish system.

5. Color: Earth-tone tan, submitted and approved by COR.

B. Deleted.

C. Wall insulation: Batt glass fiber type, faced with reinforced white vinyl.

D. Thermal Resistance Value: R value of R-13 or greater when tested in accordance with

ASTM C1363.

2.08 ACCESSORIES

A. Metal Trim, Flashings, Closures, and Similar Items:

1. Same material, finish, and color as panel system.

2. Preformed to required profile.

3. Gutters and down spouts.

B. Fasteners:

1. Manufacturer’s standard fasteners.

2. Finish exposed fasteners to match building surface.

C. Building Sealants, Gaskets, and Sealing Materials: As furnished or recommended by building manufacturer.

2.09 STEEL DOORS AND FRAMES

A. See Specifications Section 08 11 10.