B08_Solicitation_attach_2_Drawing_Spec_1_of_4.pdf
PDF 15 MB Posted
- Attached to
- JECA HVAC Replacement Federal contract opportunity
- Solicitation number
- 140P6324B0003
About this file
This file is an attachment to a solicitation for the JECA HVAC Replacement opportunity issued by the Department of the Interior National Park Service Midwest Region. The solicitation seeks proposals to replace the heating, ventilation, and air conditioning systems at various facilities. Offerors should provide pricing to remove existing HVAC equipment and install new high-efficiency systems, including all necessary ductwork, controls, and components. Proposals are due by April 15, 2023, with award expected by June 1, 2023. The period of performance is 365 days following award. This is a small business set-aside reserved for HUBZone, 8(a), women-owned, veteran-owned, or service-disabled veteran-owned small businesses.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| B09_Solicitation_Amendment_3_Attach_1_Q_and_A_2_Jan_17_2024__0003.docx | DOCX document | |
| Sol_140P6324B0003_Amd_0003.pdf | ||
| Sol_140P6324B0003_Amd_0002.pdf | ||
| Sol_140P6324B0003_Amd_0001.pdf | ||
| B09_Solicitation_Amendment_1_Attach_1_Site_Visit_List_0001.pdf | ||
| B09_Solicitation_Amendment_1_Attach_2_Question_and_Answers_0001.docx | DOCX document | |
| B08_Solicitation_attach_5_Drawing_Spec_4_of_4.pdf | ||
| B08_Solicitation_attach_1_SOW.pdf | ||
| Sol_140P6324B0003.pdf | ||
| B08_Solicitation_attach_7_WD_SD20230025_Nov_17__2023.pdf | ||
| B08_Solicitation_attach_6_Government_Clarification_Responses.pdf | ||
| B08_Solicitation_attach_4_Drawing_Spec_3_of_4.pdf | ||
| B08_Solicitation_attach_3_Drawing_Spec_2_of_4.pdf |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LOCATION OF WORK
LOCATION OF WORK
PARKING AREA LOCATED
HERE TO BE USED
FOR CONTRACTOR
STAGING ONLY.
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
325415 /
80043
C U s e rs
\z b e n n e tt \D o c u m e n ts
\0
-M
E C
H R z b e n n e tt J T
T G
W .r v t
JEK
MLB
ARP
2/24/23
07310.034
COVER SHEET
HVAC REPLACEMENT
JEWEL CAVE NATIONAL MONUMENT
CUSTER, SD
CONSTRUCTION DOCUMENTS
2/24/23
07310034- 0- 0 COVER SHEET
HVAC REPLACEMENT
JEWEL CAVE NATIONAL MONUMENT
CUSTER, SD
GENERAL
0 COVER SHEET
MECHANICAL
M 00 MECHANICAL INFO SHEET
M 01 SHEET SPECIFICATIONS - MECHANICAL
M 02 SHEET SPECIFICATIONS - MECHANICAL
M 03 SHEET SPECIFICATIONS - MECHANICAL
M 04 SHEET SPECIFICATIONS - MECHANICAL
M 05 SHEET SPECIFICATIONS - MECHANICAL
M000 DEMOLITION FLOOR PLAN - MECHANICAL
M001 DEMOLITION FLOOR PLAN - MECHANICAL
M002 DEMOLITION FLOOR PLAN - MECHANICAL
M003 DEMOLITION FLOOR PLAN - MECHANICAL
M100 FLOOR PLAN - MECHANICAL
M101 FLOOR PLAN - MECHANICAL
M102 FLOOR PLAN - MECHANICAL
M103 FLOOR PLAN - MECHANICAL
M401 DETAILS - MECHANICAL
M402 DETAILS - MECHANICAL
M501 SCHEDULE - MECHANICAL
M600 SEQUENCES
M601 SEQUENCES
M602 SEQUENCES
M603 SEQUENCES
ELECTRICAL
E 00 ELECTRICAL INFO SHEET
E 01 ELECTRICAL SPECIFICATIONS
E 02 ELECTRICAL SPECIFICATIONS
E 03 ELECTRICAL SPECIFICATIONS
E001 SUB-GRADE PLAN - DEMOLITION
E002 FIRST FLOOR PLAN - DEMOLITION
E003 SECOND FLOOR PLAN - DEMOLITION
E004 THIRD FLOOR PLAN - DEMOLITION
E101 SUB-GRADE PLAN - ELECTRICAL
E102 FIRST FLOOR PLAN - ELECTRICAL
E103 SECOND FLOOR PLAN - ELECTRICAL
E104 THIRD FLOOR PLAN - ELECTRICAL
E401 ELECTRICAL DETAILS
E501 POWER RISER DIAGRAM - DEMOLITION
E502 POWER RISER DIAGRAM
E601 ELECTRICAL SCHEDULES
DRAWING INDEX
NOT TO SCALE
Site Map
NOT TO SCALE
Region Map
TRUE
NORTH
TRUE
NORTH
DATE INITIAL
NOT TO SCALE
Site Map TRUE
NORTH
ARCHITECTURAL
A 00 ARCHITECTURAL INFO SHEET
A 01 ARCHITECTURAL SPECS
A001 DEMOLITION - CEILING PLANS
A002 DEMOLITION - CEILING PLANS, DETAILS
A101 SECOND AND THIRD FLOOR PLANS
A601 REFLECTED CEILING PLAN
A602 REFLECTED CEILING PLANS AND DETAILS
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
238608 / 80005
80005
C U s e rs \s w e h lin g
\D o c u m e n ts
\r e v it te m p \0
-A
R C
H
R s w e h lin g
.r v t
SMW
SMW
DJK
2/24/23
07310.034
A 00
ARCHITECTURAL INFO
SHEET
07310034- 2- A 00 ARCHITECTURAL INFO SHEET
HVAC REPLACEMENT
JEWEL CAVE NATIONAL MONUMENT
CUSTER, SD
XXXX
DX
XREFERENCE
NOTE
REFERENCE
DEMOLITION
NOTE
EQUIPMENT
NUMBER
ROOM NAME
150 SF
ROOM
NUMBER
REFERENCE
DESIGNATION
DEMOLITION
DESIGNATION
EQUIPMENT
NUMBER
ROOM NAME
DESIGNATION
ROOM NUMBER
DESIGNATION
ROOM AREA
DESIGNATION
SYMBOL LEGEND
ROOM /
FRAMING
ELEVATION
EXTERIOR
ELEVATION
XX-XX
XX-XX
ELEVATION LETTER
DIRECTION OF VIEW
SHEET NUMBER
ELEVATION LETTER
DIRECTION OF VIEW
SHEET NUMBER
DOOR
NUMBER
DOOR NUMBER10
WINDOW
DESIGNATION
WINDOW DESIGNATION000
TA-X
TOILET
ACCESSORY
TOILET ACCESSORY
NUMBER
WALL
TYPE
LETTER
INDICATES
PARTITION OR
WALL TYPE
X
ABBREVIATIONS
REFERENCE LEGEND
PLAN VIEW
SECTION / ELEVATION VIEW
SHEAR WALL
MASONRY-CMU
MASONRY-VENEER
STUD WALL
CONCRETE
GRAVEL
EARTH / COMPACTED
EARTH /
NONCOMPACTED
RIGID INSULATION
JOINT FILLER
STEEL
GYPSUM
FLEXIBLE INSULATION
GROUT
PLYWOOD
WOOD (FINISH)
MASONRY-CMU FACE
MASONRY-CMU
MASONRY-VENEER
S SOUTH
SA SUPPLY AIR
SAN SANITARY
SB SECURITY BARS
SB SPLASH BLOCK
SCH SCHEDULE
SCHED SCHEDULE
SCR SCREW
SCT STRUCTURAL CLAY TILE
SCUT SCUTTLE
SCW SOFT COLD WATER
SD STORM DRAIN
SD SUBDRAIN
SDI STEEL DECK INSTITUTE
SECT SECTION
SECY SECRETARY
SEQ SEQUENCE
SF SQUARE FOOT (FEET)
SFU STRUCTURAL FACING
UNIT
SHLD SHOULDER
SHT SHEET
SHTG SHEATHING
SHW SOFT HOT WATER
SIM SIMILAR
SJI STEEL JOIST INSTITUTE
SL SNOW LOAD
SLBB SHORT LEG BACK TO
BACK
SM SPRINKLER MAIN
SOV SHUT OFF VALVE
SPA SPACE(ING)
SPEC SPECIFICATIONS
SPF SOUNDPROOF
SPH SPACE HEATER
SPKR SPEAKER
SPL SPECIAL
SQ SQUARE
SS SANITARY SEWER
SS STAINLESS STEEL
SSMR STANDING SEAM METAL
ROOFING
STA STATION
STAIR STAIRWAY
STC SOUND TRANSMISSION
COEFFICIENT
STD STANDARD
STGR STRINGER
STIFF STIFFENER
STIRR STIRRUPS
STL STEEL
STN STONE
STOR STORAGE
STR STRUCTURAL
SUB FL SUB FLOOR
SUCT SUCTION
SUSP SUSPENDED
SVF SHEET VINYL FLOORING
SW SWITCH
SWBD SWITCH BOARD
SYM SYMMETRICAL
T TREAD
T or TLT TOILET
TAN TANGENT
TBD TACK BOARD
TE TOP ELEVATION
TEL TELEPHONE
TEMP TEMPERATURE
TER TERRAZZO
TERM TERMINAL
TGL TOGGLE
TH THRESHOLD
THK THICK
THRD THREAD
TO TOP OF
TOB TOP OF BEAM
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOJ TOP OF JOIST
TOPO TOPOGRAPHIC
TOS TOP OF STEEL
TOW TOP OF WALL
TRANS TRANSVERSE
TSTAT THERMOSTAT
TV TELEVISION
TW TEMPERED WATER
TWR TEMPERED WATER
RETURN
TYP TYPICAL
UC UNIT COOLER
UG UNDERGROUND
UH UNIT HEATER
UL UNDERWRITERS
LABORATORIES
UNEX UNEXCAVATED
UNFIN UNFINISHED
UNO UNLESS NOTED
OTHERWISE
UPS UNINTERRUPTIBLE
POWER SYSTEM
UR URINAL
UT UTILITY
UV UNIT VENTILATOR
V VOLT
VAC VACUUM
VAV VARIABLE AIR VOLUME
VCP VITRIFIED CLAY PIPE
VCT VINYL COMPOSITION TILE
VD VAULT DOOR
VEL VELOCITY
VENT VENTILATOR(ION)
VERT VERTICAL
VEST VESTIBULE
VFD VARIABLE FREQUENCY
DRIVE
VOL VOLUME
VPC VERTICAL POINT OF
CURVATURE
VPI VERTICAL POINT OF
INTERSECTION
VPT VERTICAL POINT OF
TANGENCY
VS VENT STACK
VT VINYL-TILE
VTR VENT THRU ROOF
VWC VINYL WALL COVERING
W WEST
W WIDE (WIDTH)
W WIRE
W/ WITH
W/O WITHOUT
WB WET BULB
WC WATER CLOSET
WC WATER COLUMN
WD WASTE DRAIN
WD WOOD
WD BLKG WOOD BLOCKING
WD DR WOOD DOOR
WDW WINDOW
WF WIDE FLANGE
WG WIRE GLASS
WH WALL HYDRANT
WHT WHITE
WI WROUGHT IRON
WKSH WORK SHOP
WL WIND LOAD
WNSCT WAINSCOT
WP WEATHER PROOF
WP WORK POINT
WPF WATER PROOF
WPFG WATER PROOFING
WRB WARDROBE
WS WASTE STACK
WT WEIGHT
WWF WELDED WIRE FABRIC
WWM WOVEN WIRE MESH
XFMR TRANSFORMER
YD YARD or YARD DRAIN
P PAINT
PA PUBLIC ADDRESS
PBS PUSH BUTTON STATION
PC PIECE
PC POINT OF CURVATURE
PC PRECAST
PCC PORTLAND CEMENT
CONCRETE
PCT PORCELAIN CERAMIC TILE
PD PRESSURE DROP
PE POLYETHYLENE
PEN PENETRATION
PERF PERFORATED
PH PHASE
PHAR PHARMACY
PI POINT OF INTERSECTION
PIV POST INDICATING VALVE
PL or P PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLATF PLATFORM
PLBG PLUMBING
PLG PILING
PLWD PLYWOOD
PNL PANEL
POL POLISH(ED)
PORC PORCELAIN
PPM PARTS PER MILLION
PR PAIR
PREFAB PREFABRICATED
PREFIN PREFINISHED
PRESS PRESSURE
PROJ PROJECT
PRV PRESSURE REGULATING
VALVE
PS PRESSED STEEL
PSFT POUNDS PER SQUARE
FOOT
PSI POUNDS PER SQUARE
INCH
PT POINT
PT POINT OF TANGENCY
PTD PAINTED
PTN PARTITION
PVC POLYVINYL-CHLORIDE
PVMT PAVEMENT
PW PASS WINDOW
1/4 RD QUARTER ROUND
QT QUARRY TILE
QT QUART
QTRS QUARTERS
QTY QUANTITY
QTZ QUARTZ
R REGISTER
R RISER
RA RETURN AIR
RAD OR
R
RADIUS
RB RESILIENT BASE
RC REMOTE CONTROL
RCP REINFORCED CONCRETE
PIPE
RD ROOF DRAIN
RE RIGHT END
REC RECEIVER
RECP RECEPTACLE
RECR RECREATION
RECT RECTIFIER
REF REFERENCE
REFR REFRIGERANT
REFR REFRIGERATOR
REG REGISTER
REINF REINFORCEMENT
REM REMOVE(ABLE)
REQD REQUIRED
RESIL RESILIENT
REV REVISIONS
RFG ROOFING
RH RELATIVE HUMIDITY
RL REFRIGERANT LIQUID
RM ROOM
RND ROUND
RO ROUGH OPENING
RPM REVOLUTIONS PER
MINUTE
RT RUBBER TILE
RTU ROOF TOP UNIT
RUB RUBBER
DIAG DIAGONAL
DIM DIMENSION
DIP DUCTILE IRON PIPE
DISC DISCONNECT
DIST DISTRIBUTION
DL DEAD LOAD
DMPR DAMPER
DN DOWN
DP DAMP PROOFING
DPT DEW POINT
DR DOOR
DRN DRAIN
DS DOWN SPOUT
DV DENTAL VACUUM
DWG DRAWING
DWLS DOWELS
DX DIRECT EXPANSION
E EAST
EA EACH
EA EXHAUST AIR
EDH ELECTRIC DUCT HEATER
EER ENERGY EFFICIENCY
RATIO
EJ EXPANSION JOINT
EL OR
ELEV
ELEVATION - GRADE OR
BUILDING
ELEC ELECTRIC OR ELECTRICAL
ELEV ELEVATOR
ENCL ENCLOSURE
ENT ENTERING
ENT ENTRANCE
EQ EQUAL
EQUIP EQUIPMENT
ES EACH SIDE
EST ESTIMATE
EVAP EVAPORATOR
EW EACH WAY
EWC ELECTRIC WATER
COOLER
EXC EXCAVATE
EXD EXIT DEVICE
EXH EXHAUST
EXIST EXISTING
EXP EXPOSED
EXPL EXPLOSION
EXPN EXPANSION
EXT EXTERIOR
F FAHRENHEIT
F
FIRE
FA FRESH AIR
FCG FACING
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEB FIRE EXTINGUISHER
BRACKET
FEC FIRE EXTINGUISHER
CABINET
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIG FIGURE
FIN FINISH
FIX FIXTURE
FL or FLR FLOOR
FLASH FLASHING
FLEX FLEXIBLE
FLG FLANGE
FLG FLOORING
FLUOR FLUORESCENT
FP FIRE PROTECTION
FPM FEET PER MINUTE
FPRF FIRE PROOF
FR FRAME
FRG FURRING
FS FAR SIDE
FS FLOOR SINK
FS FULL SIZE
FT FEET (FOOT)
FTG FOOTING
FV FIELD VERIFY
FWC FABRIC WALL COVERING
G GRILLE
G NATURAL GAS
GA GAGE OR GAUGE
GAL GALLON
GALV GALVANIZED
GEN GENERAL
GFE GOVERNMENT FURNISHED
EQUIPMENT
GFE/CI GOVERNMENT FURNISHED
EQUIPMENT/CONTRACTOR
INSTALLED
GFI GROUND FAULT
INTERRUPTER
GI GALVANIZED IRON
GL GLASS
GND GROUND
GOVT GOVERNMENT
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GR GRADE
GRS GALVANIZED RIGID STEEL
CONDUIT
GRTG GRATING
GSU GLAZED STRUCTURAL
UNITS
GWB GYPSUM WALLBOARD
GWT GLAZED WALL TILE
GYP GYPSUM
H or HT HEIGHT (HIGH)
HB HOSE BIBB
HBD HARDBOARD
HC HANDICAPPED
HD HEAD
HDPE HIGH DENSITY
POLYETHYLENE
HDR HEADER
HDW HARDWARE
HIP HIGH PRESSURE
HM HOLLOW METAL
HORIZ HORIZONTAL(LY)
HP HORSE POWER
HPS HIGH PRESURE STEAM
HPT HIGH POINT
HR HOUR
HS HIGH STRENGTH
HSGYP HIGH STRENGTH GYPSUM
PLASTER
HTG HEATING
HTR HEATER
HW HEAD WALL
HW HOT WATER
HWH HOT WATER HEATER
HWR HOT WATER RETURN
(HEATING)
HWS HOT WATER SUPPLY
(HEATING)
HYD HYDRAULIC
I or FE IRON
IC INTERCOM
ID INSIDE DIAMETER
IE INVERT ELEVATION
IES ILLUMINATING
ENGINEERING SOCIETY
IN INCH
INSUL INSULATION
INT INTERIOR
INV INVERT OR INVERTER
IP IRON PIPE
ISF INSIDE FACE
JB JUNCTION BOX
JBOX JUNCTION BOX
JC JANITOR CLOSET
JCT JUNCTION
JST JOIST
JT JOINT
K KEY
KCP KEENE'S CEMENT
PLASTER
KIP or K KILOPOUND (1000 LBS)
KIT KITCHEN
KL KEY LOCK
KP KICK PLATE
KV KILOVOLTS
KVA KILOVOLT AMPERES
KW KILOWATT
LAB LABORATORY
LAU LAUNDRY
LAV LAVATORY
LBR LUMBER
A COMPRESSED AIR
A/C AIR CONDITIONING
AB ANCHOR BOLT
ABS ACRYLONITRILE BUTAD
STYRENE
AC ALTERNATING CURRENT
ACI AMERICAN CONCRETE
INSTITUTE
ACSR ALUMINUM CONDUCTOR
STEEL REINFORCED
ACST ACOUSTIC
AD ACCESS DOOR
AD AREA DRAIN
ADMIN ADMIN ADMINISTRATION
(IVE)
AFF ABOVE FINISH FLOOR
AFFF AQUEOUS FILM FORMING
FOAM
AGG AGGREGATE
AHU AIR HANDLING UNIT
AI AREA INLET
AIC AMPS INTERRUPTING
CAPACITY (SYM RMS)
AISC AMERICAN INSTITUTE OF
STEEL CONSTRUCTION
AL ACTIVE LEAF
AL ALUMINUM
ALT ALTERNATE
AMP AMPERE
ANSI AMERICAN NATIONAL
STANDARDS INSTITUTE
AP ACCESS PANEL
APD AIR PRESSURE DROP
APPD APPROVED
APPROX APPROXIMATE
ARCH ARCHITECTURAL OR
ARCHITECT
ARI AMERICAN
REFRIGERATION
INSTITUTE
ASB ASBESTOS
ASPH ASPHALT
APC ACOUSTICAL PANEL
CEILING
AUTO AUTOMATIC
AV ACID VENT
AVG AVERAGE
AW ACID WASTE
AWC ACOUSTICAL WALL
COVERING
AWG AMERICAN WIRE GAUGE
L ANGLE
BATT BATT INSULATION
BB BULLETIN BOARD
BBO BOILER BLOW OFF
BC BOOKCASE
BD BOARD
BDY BOUNDARY
BEJ BRICK EXPANSION JOINT
BIT BITUMINOUS
BKR BREAKER
BL BUILDING LINE
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BM BENCH MARK
BO BOTTOM OF
BOT BOTTOM
BRCG BRACING
BRDG BRIDGING
BRG BEARING
BRK BRICK
BRKT BRACKET
BS BOTH SIDES
BTU BRITISH THERMAL UNIT
BTUH BTU PER HOUR
BUR BUILT-UP ROOFING
BW BOTH WAYS
C CENTER
C OR
CND
CONDUIT (ELECTRICAL
SHEETS)
C TO C CENTER TO CENTER
CAP CAPACITY
CB CATCH BASIN (OR CIRCUIT
BREAKER)
CC CENTER TO CENTER
CCT CIRCUIT
CD CONDENSATE DRAIN
CE COVER ELEVATION
CEM CEMENT
CF CUBIC FEET
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CHIM CHIMNEY
CI CAST IRON
CI CURB INLET
CIP CAST IN PLACE
CIR CIRCULAR
CJ CONTROL JOINT
CKT CIRCUIT
CL CENTER LINE
CL WG CLEAR WIRE GLASS
CLG CEILING
CLKG CAULKING
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY
UNIT
CNTR COUNTER
CO CLEAN OUT
CO2 CARBON DIOXIDE
COL COLUMN
COM COMMON
COMB COMBINATION
COMB COMBUSTION
COMP COMPRESSIBLE
COMPR COMPRESSOR
CONC CONCRETE
CONF CONFERENCE
CONN CONNECTION
CONSTR CONSTRUCTION
CONSTR
JT
CONSTRUCTION JOINT
CONT CONTINUOUS
(CONTINUATION)
CONTR CONTRACTOR
COR CORNER
CORR
COVEREDCOV
CORRIDOR
CPL CEMENT PLASTER
CPS CYCLES PER SECOND
(HERTZ)
CPT CARPET
CR CONDENSER WATER
RETURN
CRES CORROSIVE RESISTANT
STEEL
CRG CARRIAGE
CRSE COURSE
CS CONDENSER WATER
SUPPLY
CS COUNTER SINK
CSMT CASEMENT
CT CERAMIC TILE
CT CURRENT TRANSFORMER
CTL CARPET TILE
CU CONDENSING UNIT
CU YD CUBIC YARDS
CUH CABINET UNIT HEATER
CV CEILING VENT
CW COLD WATER
CWR CHILLED WATER RETURN
CWS CHILLED WATER SUPPLY
CYL CYLINDER
D DEPTH (DEEP)
D DIFFUSER
d PENNY (as in nail - 10d)
D&M DRESSED AND MATCHED
DA DOUBLE ACTING
DB DRY BULB
dB DECIBEL
DBL DOUBLE
DC DIRECT CURRENT
DCJ DOWELED CONTROL
JOINT
DCJT DUMMY CONTROL JOINT
DCL DOOR CLOSER
DCW DOMESTIC COLD WATER
DEG DEGREE
DEMO DEMOLITION
DEPR DEPRESSION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DH DOUBLE HUNG
DHW DOMESTIC HOT WATER
DI DEIONIZED WATER
DIA DIAMETER
CLO CLOSET
FR FIRE RATED
U/C UNDER CABINET
CBU CEMENTITIOUS BACKER
UNIT
F FLUSH or FRAME
FG FULL GLASS
G GLASS or GLASS TYPE
HG HALF GLASS
V VISION
SL SLIDING
BF(2) BIFOLD (DOUBLE)
IG INSULATED GLASS
SS SOLID SURFACE
WIDTH DEPTH
HEIGHT
CABINET DESIGN
SERIES MODELCASEWORK
TAG
DWR DRAWER
CAB CABINET
SHV SHELF OR SHELVES
SNGL SINGLE
GENERAL NOTES
LBS POUNDS
LD LOAD
LDG LOADING
LE LEFT END
LG LENGTH (LONG)
LIN LINEAR
LIS LAWN IRRIGATION
SYSTEM
LL LIVE LOAD
LLBB LONG LEG BACK TO BACK
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LNTL LINTEL
LP LOW POINT
LPG LIQUIFIED PETROLEUM
GAS
LPS LOW PRESSURE STEAM
LR LIVING ROOM
LS LAWN SPRINKLER
LT LIGHT
LT WT LIGHT WEIGHT
LTG LIGHTING
LVT LUXURY VINYL TILE
M MIDDLE
M THOUSAND
M & B MATCHED AND BEADED
MA MAKE-UP AIR
MACH MACHINE
MAS MASONRY
MAT or
MATL
MATERIAL
MAX MAXIMUM
MB MACHINE BOLT
MBH 1000 BTUH
MC MEDICINE CABINET
MC MISCELLANEOUS
CHANNELS
MECH MECHANICAL
MER MECHANICAL EQUIPMENT
ROOM
MET METAL
MFG MANUFACTURING
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
ML METAL LATH
MLDG MOULDING
MO MASONRY OPENING
MONO MONOLITHIC
MT METAL THRESHOLD
MTD MOUNTED
N NORTH
NC NORMALLY CLOSED
NEC NATIONAL ELECTRICAL
CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURERS
ASSOCIATION
NFPA NATIONAL FIRE
PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NO NUMBER
NR NOT REQUIRED
NS NEAR SIDE
NTS NOT TO SCALE
OA OUTSIDE AIR
OB WG OBSCURE WIRE GLASS
OBGL OBSCURE GLASS
OBSC OBSCURE
OC ON CENTER(S)
OCEW ON CENTER EACH WAY
OD OUTSIDE DIAMETER
OFF OFFICE
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
OPS OPERATIONS
OS & Y OUTSIDE SCREW & YOKE
OSF OUTSIDE FACE
OV OVERFLOW VALVE
OX OXYGEN
OZ OUNCE
NV NARROW VISION
MICRO MICROWAVE
NORTH
ARROW
NAME
ELEVATION
LEVEL
MATCHLINE
AREA A
AREA B
TITLE
MARKER
VIEW NAME
SCALE: 1/8" = 1'-0"
EXISTING
COLUMN
NEW
COLUMN
X
X
X
XX-XX
SIM
X
XX-XX
SECTION/
DETAIL
PLAN
DETAIL
LETTER INDICATES
NEW COLUMN LINE
LETTER INDICATES
EXISTING COLUMN LINE
SECTION/DETAIL
NUMBER
SHEET NUMBER
INDICATES DIRECTION
OF VIEW
DETAIL NUMBER
SHEET NUMBER
DETAIL NUMBER
LEVEL CALLOUT
DESIGNATION
ELEVATION
DESIGNATION
GRAPHIC AREA FOR
DRAWING
TITLE
SCALE OF THE
DRAWING
NORTH PLAN
NORTH
TRUE
NORTH
GENERAL DEMO NOTES
ARCHITECTURAL SHEET LIST
X
PROJECT ARCHITECTURAL REFERENCED NOTES
REF. NOTES ( )
REF. DEMO NOTES ( )
PROJECT ARCHITECTURAL REFERENCED DEMOLITION NOTES
DX
A 00 ARCHITECTURAL INFO SHEET
A 01 ARCHITECTURAL SPECS
A001 DEMOLITION - CEILING PLANS
A002 DEMOLITION - CEILING PLANS, DETAILS
A101 SECOND AND THIRD FLOOR PLANS
A601 REFLECTED CEILING PLAN
A602 REFLECTED CEILING PLANS AND DETAILS
A. THE DEMOLITION PLANS WERE PRODUCED BY DUPLICATING THE ORIGINAL DRAWINGS PROVIDED BY
THE OWNER AND LIMITED FIELD VERIFICATION. DIMENSIONS AND EXISTING CONDITIONS ARE
APPROXIMATE. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS. ITEMS WHICH ARE
INTENDED TO BE REMOVED, RELOCATED, OR SALVAGED ARE SHOWN AS FULL-TONE DASHED LINES AND ARE LISTED IN THE REFERENCED DEMOLITION NOTES. ALL OTHER ITEMS ARE INTENDED TO
REMAIN IN PLACE AND ARE SHOWN HALF-TONE.
B. DEMOLITION SHALL INCLUDE, BUT IS NOT LIMITED TO, THE ITEMS BELOW OR HERE-IN. THE CONTRACTOR SHALL COORDINATE ALL REQUIRED RENOVATION AND NEW CONSTRUCTION WITH THE EXISTING BUILDING TO IDENTIFY THE TOTAL EXTENT OF THE DEMOLITION REQUIRED AND AS LISTED
BELOW.
C. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DEMOLITION AND REMOVAL OF ALL EXISTING BUILDING COMPONENTS, MATERIALS, EQUIPMENT, AND APPURTENANCES AS REQUIRED TO BUILD, ERECT, INSTALL, OR ACCOMMODATE ALL NEW CONSTRUCTION WITH THE OWNER HAVING FIRST RIGHT
OF REFUSAL ON ALL ITEMS.
D. ITEMS NOTED TO BE REMOVED AND SALVAGED OR REINSTALLED SHALL BE CAREFULLY REMOVED BY
THE CONTRACTOR WITHOUT DAMAGE AND STORED OR REINSTALLED ON THE SITE AS DIRECTED.
REMOVED AND SALVAGED ITEMS SHALL REMAIN THE PROPERTY OF THE OWNER.
E. WHERE EXISTING FLOOR MATERIALS AND/OR WALLS ARE TO BE REMOVED, PREP REMAINING FLOOR
AND/OR WALL SUBSTRATE AS REQUIRED PER MANUFACTURERS RECOMMENDATIONS FOR THE NEW
FLOOR/WALL FINISH MATERIAL. REMOVE ALL FINISH FLOORING DOWN TO BASE SUBSTRATE FLOORING
AND PREP TO RECEIVE NEW FINISH.
F. IN THE EVENT THE CONTRACTOR ENCOUNTERS ON THE SITE, MATERIAL REASONABLY BELIEVED TO BE
ASBESTOS, LEAD-BASED PAINT, OR ANY OTHER HAZARDOUS MATERIAL WHICH HAS NOT BEEN
RENDERED HARMLESS, THE CONTRACTOR SHALL IMMEDIATELY STOP WORK IN THE AREA AFFECTED
AND REPORT THE CONDITION TO THE OWNER AND ARCHITECT IN WRITING. THE WORK IN THE
AFFECTED AREA SHALL NOT THEREAFTER BE RESUMED EXCEPT BY WRITTEN AGREEMENT OF THE
OWNER AND CONTRACTOR.
G. THE CONTRACTOR IS RESPONSIBLE FOR THE ERECTION, MAINTENANCE, AND REMOVAL OF ALL
CONSTRUCTION BARRIERS.
H. REMOVE EXISTING ELEMENTS/FINISHES NOT REQUIRED IN THE COMPLETED PROJECT, BUT
CONFLICTING WITH NEW FINISHES. THESE ELEMENTS/FINISHES SHALL INCLUDE, BUT ARE NOT LIMITED
TO THE ITEMS LISTED BELOW:
1. REMOVE EXISTING CEILING SUSPENSION SYSTEMS ANYWHERE NEW CEILINGS ARE INDICATED PER
THE REFLECTED CEILING PLAN AND ROOM FINISH SCHEDULE
I. ALL EXISTING WALLS, DOORS, FRAMES, AND WINDOWS SHOWN ON THE PLAN AS A FULL-TONE DASHED
LINE ARE TO BE REMOVED.
J. REFER TO MECHANICAL DEMOLITION PLANS FOR ADDITIONAL DEMOLITION REQUIRED TO
ACCOMMODATE NEW MECHANICAL PIPING AND ASSOCIATED EQUIPMENT.
A. EXISTING CONDITIONS ARE BASED ON DRAWINGS PROVIDED BY THE OWNER AND LIMITED FIELD VERIFICATION. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS AND NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES OR VARIATIONS FROM THOSE SHOWN
ON THE DRAWINGS. THE CONTRACTOR SHALL ADJUST TO ACTUAL FIELD CONDITIONS AT NO
ADDITIONAL EXPENSE TO THE OWNER.
B. ALL CONTRACTORS ARE RESPONSIBLE FOR REVIEWING ENTIRE SET OF DOCUMENTS TO DETERMINE THEIR FULL SCOPE OF WORK. CONTRACTOR SHALL NOT BE ALLOWED EXTRA COSTS DUE TO FAILURE
TO REVIEW ENTIRE SET OF DOCUMENTS.
C. CONTRACTOR SHALL TAKE ALL MEASUREMENTS FOR WORK AND BE RESPONSIBLE FOR SAME.
CONTRACTOR SHALL ADJUST FOR ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO OWNER.
COORDINATE THE WORK AND SHOP DRAWINGS WITH ALL OTHER TRADES AFFECTED.
D. SCREENED HALF-TONE LINES INDICATE EXISTING CONSTRUCTION TO REMAIN. FULL-TONE LINES
INDICATE NEW OR RELOCATED CONSTRUCTION.
E. DIMENSIONS ARE TYPICALLY TO FINISH FACE OF GYPSUM WALL BOARD; OR CENTER LINE OF COLUMN
OR BEAMS, UNLESS NOTED OTHERWISE.
F. ALL ANGLES ON THE FLOOR PLANS ARE 45 OR 90 DEGREES UNLESS OTHERWISE INDICATED.
G. ALL CONTROL JOINTS (CJ) SHALL BE CAULKED AT EXTERIOR WALL LOCATIONS AND RAKED BACK 3/4
INCH AT ALL INTERIOR JOINTS UNLESS OTHERWISE NOTED.
H. PATCH EXISTING WALLS, FLOORS, AND CEILING SURFACES DEMOLISHED, CUT, CORED, OR ALTERED IN
ANY WAY TO ACCOMMODATE NEW CONSTRUCTION OR TO RECEIVE NEW FINISHES. PREP ALL
EXISTING FLOORS TO RECEIVE NEW FINISHES PER ROOM FINISH SCHEDULE.
I. PATCH ALL CONCRETE SLAB LOCATIONS DEMOLISHED TO INSTALL NEW STRUCTURAL, MECHANICAL, OR ELECTRICAL WORK.
1 GWB CEILING - FIELD VERIFY THICKNESS TO MATCH EXISTING,
BLOWN IN ATTIC INSULATION (R-49 MIN) AND 6 MIL VAPOR
BARRIER WHERE OCCURS, COORDINATE EXTENTS WITH
MECH. VERIFY CEILING HEIGHTS TO MATCH EXISTING.
2 ACOUSTICAL CEILING TILES ADHERED TO GWB FIELD VERIFY
THICKNESS TO MATCH EXISTING WITH BLOWN IN ATTIC
INSULATION (R-49 MIN) ABOVE AND 6 MIL VAPOR BARRIER
WHERE OCCURS TO MATCH EXISTING, COORDINATE EXTENTS
WITH MECH. VERIFY CEILING HEIGHTS TO MATCH EXISTING.
3 PATCH WALL AT ABANDONED MECHANICAL VENT TO MATCH
EXISTING FINISH.
4 PATCH GWB AS REQUIRED WITH REPLACEMENT OF ACOUSTIC
CEILING.
5 PATCH WALL AS REQUIRED TO MATCH EXISTING FOR NEW
MECHANICAL OUTSIDE AIR DUCT, COORDINATE EXTENTS WITH
MECHANICAL.
6 CEILING ACCESS HATCH, 12 X 12, INSULATED, FIRE RATED
ACCESS PANEL, BABCOCK-DAVIS (OR EQUAL) B-IW SERIES
7 PATCH EXTERIOR WALL FOR NEW PIPE. COORDINATE
EXTENTS WITH MECH.
8 PROTECT CAVE REPLICA COMPONENTS WHERE OCCURS
DURING REMOVAL OF EXISTING CEILING. PATCH ANY
DAMAGED AREA DURING CONSTRUCTION.
9 MECH EQUIPMENT - SEE MECH
10 5/8" TYPE 'X' GWB CEILING ON 2X STUDS, COORDINATE
EXTENTS WITH MECH.
11 PATCH WALL TO WITH STUDS, GWB WITH PAINT FINISH TO
MATCH EXISTING AS REQUIRED FOR NEW MECHANICAL PIPES,
COORDINATE EXTENTS WITH MECHANICAL.
12 GWB CEILING - FIELD VERIFY THICKNESS TO MATCH EXISTING.
COORDINATE EXTENTS WITH MECH. VERIFY CEILING HEIGHTS
TO MATCH EXISTING.
13 AT AREA OF REMOVED FLUE THROUGH ROOF, PATCH
ROOFING TO MATCH EXISTING AND BE WEATHERTIGHT.
ROOFING TO BE 60 MIL S327-15 "TAN" RHINOBOND TO
WITHSTAND 60 MPH WINDS. COORDINATE LOCATION WITH
MECHANICAL.
D1 REMOVE EXISTING ACOUSTIC CEILING TILE, GWB BACKING
AND ATTIC INSULATION, COORDINATE EXTENTS WITH
MECHANICAL. ASSUME ATTIC INSULATION CONTAINMENT.
D2 REMOVE EXISTING GWB CEILING AND ATTIC INSULATION,
COORDINATE EXTENTS WITH MECHANICAL. ASSUME ATTIC
INSULATION CONTAINMENT.
D3 REMOVE EXISTING WALL AS REQUIRED FOR NEW MECHANICAL
PIPES. COORDINATE EXTENTS WITH MECHANICAL.
D4 REMOVE EXISTING GWB CEILING FOR NEW MECHANICAL
EQUIPMENT, COORDINATE EXTENTS WITH MECHANICAL.
D5 REMOVE EXISTING WALL FOR MECHANICAL OUTSIDE AIR
DUCT. COORDINATE EXTENTS WITH MECHANICAL.
DATE INITIAL
CODE SUMMARY
APPLICABLE CODES
BUILDING :
ACCESSIBILITY :
LIFE SAFETY :
ENERGY :
MECHANICAL :
PLUMBING :
ELECTRICAL :
OCCUPANCY GROUP :
TYPE OF CONSTRUCTION :
MAXIMUM ALLOWED HEIGHT
MAXIMUM ALLOWED AREA
MIXED USE SEPARATIONS :
HEIGHT AND AREA LIMITS
EXTERIOR WALL OPENING LIMITS :
DRAFTSTOPS :
FIRE PROTECTIVE SYSTEMS
FIRE SEPARATION ASSEMBLIES
EXITS
SHAFTS / HOISTWAYS
DWELLING UNIT SEPARATIONS
INTERIOR LOAD BEARING
WALLS, COLUMNS, FRAMING
ROOF CONSTRUCTION
FLOOR CONSTRUCTION
FIRE WALLS
FIRE RESISTANCE OF STRUCTURAL
ELEMENTS
RATING
(HOURS)
DESIGN
NUMBER
EXTERIOR WALLS
LOAD BEARING WALLS
NON-LOAD BEARING WALLS
CALCULATIONS
DOOR
STAIR
M/B
III-B
55'
65,625 SF
2010 ADA
NA
2021 NFPA 101
2015 IECC
2015 IMC
2009 UPC
2020 NEC
2018 IBC
UL
UL
UL
UL
UL
UL
UL
UL
UL
0.2" / OCC
0.3" / OCC
SECTION 092900 - GYPSUM BOARD
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Interior gypsum board.
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product.
PART 2 - PRODUCTS
2.1 PERFORMANCE REQUIREMENTS
A. Fire-Resistance-Rated Assemblies: For fire-resistance-rated assemblies, provide materials and construction identical to those tested in UL assembly indicated in Drawings.
2.2 INTERIOR GYPSUM BOARD
A. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:
1. American Gypsum.
2. Georgia-Pacific Gypsum LLC.
3. National Gypsum Company.
4. USG Corporation.
B. Gypsum Board, Type X: ASTM C 1396/C 1396M.
1. Thickness: 5/8 inch.
2. Long Edges: Tapered.
3. All fire rated assemblies and as noted.
C. Gypsum Ceiling Board: ASTM C 1396/C 1396M.
1. Thickness: 5/8 inch, Type X.
2. Long Edges: Tapered.
3. All ceilings.
2.3 TRIM ACCESSORIES
A. Interior Trim: ASTM C 1047.
1. Material: Paper-faced galvanized steel sheet or plastic.
2. Shapes:
a. L-Bead: L-shaped; exposed long flange receives joint compound.
b. Expansion (control) joint.
2.4 JOINT TREATMENT MATERIALS
A. General: Comply with ASTM C 475/C 475M.
B. Joint Tape:
1. Interior Gypsum Board: Paper.
2. Glass-Mat Gypsum Sheathing Board: 10-by-10 glass mesh.
C. Joint Compound for Interior Gypsum Board: For each coat use formulation that is compatible with other compounds applied on previous or for successive coats.
1. Prefilling: At open joints and damaged surface areas, use setting-type taping compound.
2. Embedding and First Coat: For embedding tape and first coat on joints, fasteners, and trim flanges, use drying-type, all-purpose compound.
3. Fill Coat: For second coat, use drying-type, all-purpose compound.
4. Finish Coat: For third coat, use setting-type, sandable topping compound.
2.5 AUXILIARY MATERIALS
A. Steel Drill Screws: ASTM C 1002, unless otherwise indicated.
B. Sound Attenuation Blankets: ASTM C 665, Type I (blankets without membrane facing).
PART 3 - EXECUTION
3.1 APPLYING AND FINISHING PANELS
A. Comply with ASTM C 840.
B. Install ceiling panels across framing to minimize the number of abutting end joints and to avoid abutting end joints in central area of each ceiling. Stagger abutting end joints of adjacent panels not less than one framing member.
C. Do not place tapered edges against cut edges or ends.
D. Examine panels before installation. Reject panels that are wet or damaged.
E. Install trim with back flanges intended for fasteners, attach to framing with same fasteners used for panels.
Otherwise, attach trim according to manufacturer's written instructions.
1. Edge Trim: Install at perimeter edge of gypsum board where it meets masonry walls.
2. Control Joints: Install control joints at locations indicated on Drawings.
F. Form control joints, with double joists spaced (1/2 inch) apart.
G. Prefill open joints and damaged surface areas.
H. Apply joint tape over gypsum board joints, except for trim products specifically indicated as not intended to receive tape.
I. Gypsum Board Finish Levels: Finish panels to levels indicated below and according to ASTM C 840:
1. Level 4: At all exposed interior ceiling surfaces.
2. Level 4: At all interior wall surfaces.
3. Level 3: At all interior ceiling surfaces with ACT as a finish material adhered to GWB.
J. Protect adjacent surfaces from drywall compound and finishes and promptly remove from non-drywall surfaces.
Repair surfaces stained, marred, or otherwise damaged during drywall application.
K. Remove and replace panels that are wet or damaged.
END OF SECTION
SECTION 095113 - ACOUSTICAL PANEL CEILINGS
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes acoustical panels and exposed suspension systems for interior ceilings.
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product.
B. Samples: For each exposed product and for each color and texture specified.
PART 2 - PRODUCTS
2.1 PERFORMANCE REQUIREMENTS
A. Seismic Performance: Suspended ceilings shall withstand the effects of earthquake motions determined according to ASCE/SEI 7.
B. Surface-Burning Characteristics: Comply with ASTM E 84; testing by a qualified testing agency. Identify products with appropriate markings of applicable testing agency.
1. Flame-Spread Index: Class A according to ASTM E 1264.
2. Smoke-Developed Index: 50 or less.
2.2 ACOUSTICAL PANELS
A. Match existing acoustical panels.
PART 3 - EXECUTION
3.1 PREPARATION
A. Measure each ceiling area and establish layout of acoustical panels to balance border widths at opposite edges of each ceiling. Avoid using less-than-half-width panels at borders unless otherwise indicated.
B. Layout openings for penetrations centered on the penetrating items.
3.2 INSTALLATION
A. Install acoustical panel ceilings according to ASTM C 636/C 636M and manufacturer's written instructions.
B. Install edge moldings and trim of type indicated at perimeter of acoustical ceiling area and where necessary to conceal edges of acoustical panels.
1. Do not use exposed fasteners, including pop rivets, on moldings and trim.
C. adhere act to gwb to match adjacent profile.
END OF SECTION
SECTION 099123 - INTERIOR PAINTING
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes surface preparation and the application of paint systems on interior substrates.
1. Gypsum Board
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product. Include preparation requirements and application instructions.
B. Samples: For each type of paint system and in each color and gloss of topcoat.
1.3 MAINTENANCE MATERIAL SUBMITTALS
A. Furnish extra materials, from the same product run, that match products installed and that are packaged with protective covering for storage and identified with labels describing contents.
1. Paint: 5 percent, but not less than 3.8 L (1 gal.) of each material and color applied.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Manufacturers: Subject to compliance with requirements, provide products by one of the following:
1. Benjamin Moore & Co.
2. Diamond Vogel Paints.
3. ICI Paints.
4. Kelly-Moore Paints.
5. Kwal Paint.
6. PPG Architectural Finishes, Inc.
7. Pratt & Lambert.
8. Royal Paints.
9. Sherwin-Williams Company (The).
2.2 PAINT, GENERAL
A. Material Compatibility:
1. Provide materials for use within each paint system that are compatible with one another and substrates indicated, under conditions of service and application as demonstrated by manufacturer, based on testing and field experience.
2. For each coat in a paint system, provide products recommended in writing by manufacturers of topcoat for use in paint system and on substrate indicated.
B. Colors: As selected by COR from Manufacturer’s full range of color options.
2.3 PRIMERS/SEALERS
A. Primer Sealer, Latex, Interior: MPI #50.
1. See Painting Schedule at the end of this Section.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine substrates and conditions, with Applicator present, for compliance with requirements for maximum moisture content and other conditions affecting performance of the Work.
B. Maximum Moisture Content of Substrates: When measured with an electronic moisture meter as follows:
1. Concrete: 12 percent.
2. Masonry (Clay and CMU): 12 percent.
3. Wood: 15 percent.
4. Gypsum Board: 12 percent.
C. Verify suitability of substrates, including surface conditions and compatibility with existing finishes and primers.
D. Proceed with coating application only after unsatisfactory conditions have been corrected.
1. Application of coating indicates acceptance of surfaces and conditions.
3.2 PREPARATION
A. Comply with manufacturer's written instructions and recommendations in "MPI Manual" applicable to substrates indicated.
B. Remove hardware, covers, plates, and similar items already in place that are removable and are not to be painted.
If removal is impractical or impossible because of size or weight of item, provide surface-applied protection before surface preparation and painting.
1. After completing painting operations, use workers skilled in the trades involved to reinstall items that were removed. Remove surface-applied protection if any.
C. Clean substrates of substances that could impair bond of paints, including dust, dirt, oil, grease, and incompatible paints and encapsulants.
1. Remove incompatible primers and reprime substrate with compatible primers or apply tie coat as required to produce paint systems indicated.
3.3 APPLICATION
A. Apply paints according to manufacturer's written instructions and to recommendations in "MPI Manual."
B. Apply paints to produce surface films without cloudiness, spotting, holidays, laps, brush marks, roller tracking, runs, sags, ropiness, or other surface imperfections. Cut in sharp lines and color breaks.
3.4 CLEANING AND PROTECTION
A. Protect work of other trades against damage from paint application. Correct damage to work of other trades by cleaning, repairing, replacing, and refinishing, as approved by Architect, and leave in an undamaged condition.
B. At completion of construction activities of other trades, touch up and restore damaged or defaced painted surfaces.
3.5 INTERIOR PAINTING SCHEDULE
A. Gypsum Board Substrates:
1. Institutional Low-Odor/VOC Latex System:
a. Prime Coat: Primer sealer, interior, institutional low odor/VOC, MPI #149.
b. Intermediate Coat: Latex, interior, institutional low odor/VOC, matching topcoat.
c. Topcoat: Latex, interior, institutional low odor/VOC, MPI #144, for ceilings
d. Topcoat: Latex, interior, institutional low odor/VOC, MPI #146, all surfaces other than ceilings
END OF SECTION
SECTION 072100 - THERMAL INSULATION
PART 1 - GERNERAL
1.1 SUMMARY
A. Section Includes:
1. Glass-fiber blanket.
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product.
PART 2 - PRODUCTS
2.1 GLASS-FIBER BLANKET
A. Glass-Fiber Blanket, Unfaced: ASTM C 665, Type I; with maximum flame-spread and smoke-developed indexes of 25 and 50, respectively, per ASTM E 84; passing ASTM E 136 for combustion characteristics.
1. Manufacturers: Subject to compliance with requirements, provide products by one of the following:
a. CertainTeed Corporation.
b. Johns Manville; a Berkshire Hathaway company.
c. Knauf Insulation.
d. Owens Corning.
2.2 ACCESSORIES
A. Insulation for Miscellaneous Voids:
1. Glass-Fiber Insulation: ASTM C 764, Type II, loose fill; with maximum flame-spread and smoke-developed indexes of 5, per ASTM E 84.
B. Insulation Anchors, Spindles, and Standoffs: As recommended by manufacturer.
C. Adhesive for Bonding Insulation: Product compatible with insulation and air and water barrier materials, and with demonstrated capability to bond insulation securely to substrates without damaging insulation and substrates.
PART 3 - EXECUTION
3.1 INSTALLATION, GENERAL
A. Comply with insulation manufacturer's written instructions applicable to products and applications.
B. Extend insulation to envelop entire area to be insulated. Fit tightly around obstructions and fill voids with insulation.
Remove projections that interfere with placement.
3.2 INSTALLATION OF INSULATION IN FRAMED CONSTRUCTION
A. Blanket Insulation: Install in cavities formed by framing members according to the following requirements:
1. Use insulation widths and lengths that fill the cavities formed by framing members. If more than one length is required to fill the cavities, provide lengths that will produce a snug fit between ends.
2. Place insulation in cavities formed by framing members to produce a friction fit between edges of insulation and adjoining framing members.
3. Maintain 3-inch clearance of insulation around recessed lighting fixtures not rated for or protected from contact with insulation.
4. Vapor-Retarder-Faced Blankets: Tape joints and ruptures in vapor-retarder facings, and seal each continuous area of insulation to ensure airtight installation.
a. Exterior Walls: Set units with facing placed toward interior of construction.
B. Miscellaneous Voids: Install insulation in miscellaneous voids and cavity spaces where required to prevent gaps in insulation using the following materials:
1. Glass-Fiber Insulation: Compact to approximately 40 percent of normal maximum volume equaling a density of approximately 2.5 lb/cu. ft.
END OF SECTION
SECTION 024119 - SELECTIVE DEMOLITION
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Demolition and removal of selected portions of building or structure.
2. Demolition and removal of selected site elements.
3. Salvage of existing items to be reused or recycled.
1.2 MATERIALS OWNERSHIP
A. Unless otherwise indicated, demolition waste becomes property of Contractor.
1.3 PREINSTALLATION MEETINGS
A. Predemolition Conference: Conduct conference at Project site.
1.4 INFORMATIONAL SUBMITTALS
A. Proposed Protection Measures: Submit report, including Drawings, that indicates the measures proposed for protecting individuals and property, for environmental protection, for dust control and, for noise control. Indicate proposed locations and construction of barriers.
B. Schedule of selective demolition activities with starting and ending dates for each activity.
C. Predemolition photographs or video.
1.5 CLOSEOUT SUBMITTALS
A. Inventory of items that have been removed and salvaged.
1.6 FIELD CONDITIONS
A. Owner will occupy portions of building immediately adjacent to selective demolition area. Conduct selective demolition so Owner's operations will not be disrupted.
B. Conditions existing at time of inspection for bidding purpose will be maintained by Owner as far as practical.
C. Notify Architect of discrepancies between existing conditions and Drawings before proceeding with selective demolition.
D. Hazardous Materials: It is not expected that hazardous materials will be encountered in the Work.
1. If suspected hazardous materials are encountered, do not disturb; immediately notify Architect and Owner.
Hazardous materials will be removed by Owner under a separate contract.
E. Storage or sale of removed items or materials on-site is not permitted.
F. Utility Service: Maintain existing utilities indicated to remain in service and protect them against damage during selective demolition operations.
1. Maintain fire-protection facilities in service during selective demolition operations.
G. Arrange selective demolition schedule so as not to interfere with Owner's operations.
1.7 WARRANTY
A. Existing Warranties: Remove, replace, patch, and repair materials and surfaces cut or damaged during selective demolition, by methods and with materials and using approved contractors so as not to void existing warranties.
PART 2 - PRODUCTS
2.1 PERFORMANCE REQUIREMENTS
A. Regulatory Requirements: Comply with governing EPA notification regulations before beginning selective demolition.
Comply with hauling and disposal regulations of authorities having jurisdiction.
B. Standards: Comply with ASSE A10.6 and NFPA 241.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Verify that utilities have been disconnected and capped before starting selective demolition operations.
B. Perform an engineering survey of condition of building to determine whether removing any element might result in structural deficiency or unplanned collapse of any portion of structure or adjacent structures during selective building demolition operations.
C. Inventory and record the condition of items to be removed and salvaged.
3.2 UTILITY SERVICES AND MECHANICAL/ELECTRICAL SYSTEMS
A. Existing Services/Systems to Remain: Maintain services/systems indicated to remain and protect them against damage.
B. Existing Services/Systems to Be Removed, Relocated, or Abandoned: Locate, identify, disconnect, and seal or cap off utility services and mechanical/electrical systems serving areas to be selectively demolished.
1. Arrange to shut off utilities with utility companies.
2. If services/systems are required to be removed, relocated, or abandoned, provide temporary services/systems that bypass area of selective demolition and that maintain continuity of services/systems to other parts of building.
3. Disconnect, demolish, and remove fire-suppression systems, plumbing, and HVAC systems, equipment, and components indicated on Drawings to be removed.
a. Piping to Be Removed: Remove portion of piping indicated to be removed and cap or plug remaining piping with same or compatible piping material.
b. Piping to Be Abandoned in Place: Drain piping and cap or plug piping with same or compatible piping material and leave in place.
c. Equipment to Be Removed: Disconnect and cap services and remove equipment.
d. Equipment to Be Removed and Reinstalled: Disconnect and cap services and remove, clean, and store equipment; when appropriate, reinstall, reconnect, and make equipment operational.
e. Equipment to Be Removed and Salvaged: Disconnect and cap services and remove equipment and deliver to Owner.
f. Ducts to Be Removed: Remove portion of ducts indicated to be removed and plug remaining ducts with same or compatible ductwork material.
g. Ducts to Be Abandoned in Place: Cap or plug ducts with same or compatible ductwork material and leave in place.
3.3 PROTECTION
A. Temporary Protection: Provide temporary barricades and other protection required to prevent injury to people and damage to adjacent buildings and facilities to remain.
B. Temporary Shoring: Design, provide, and maintain shoring, bracing, and structural supports as required to preserve stability and prevent movement, settlement, or collapse of construction and finishes to remain, and to prevent unexpected or uncontrolled movement or collapse of construction being demolished.
C. Remove temporary barricades and protections where hazards no longer exist.
3.4 SELECTIVE DEMOLITION
A. General: Demolish and remove existing construction only to the extent required by new construction and as indicated. Use methods required to complete the Work within limitations of governing regulations and as follows:
1. Neatly cut openings and holes plumb, square, and true to dimensions required. Use cutting methods least likely to damage construction to remain or adjoining construction. Use hand tools or small power tools designed for sawing or grinding, not hammering and chopping. Temporarily cover openings to remain.
2. Cut or drill from the exposed or finished side into concealed surfaces to avoid marring existing finished surfaces.
3. Do not use cutting torches until work area is cleared of flammable materials. At concealed spaces, such as duct and pipe interiors, verify condition and contents of hidden space before starting flame-cutting operations.
Maintain portable fire-suppression devices during flame-cutting operations.
4. Maintain fire watch during and after flame-cutting operations per Owner’s Safety Requirements.
5. Locate selective demolition equipment and remove debris and materials so as not to impose excessive loads on supporting walls, floors, or framing.
6. Dispose of demolished items and materials promptly.
B. Site Access and Temporary Controls: Conduct selective demolition and debris-removal operations to ensure minimum interference with roads, streets, walks, walkways, and other adjacent occupied and used facilities.
C. Removed and Salvaged Items:
1. Clean salvaged items.
2. Pack or crate items after cleaning. Identify contents of containers.
3. Store items in a secure area until delivery to Owner.
4. Transport items to Owner's storage area on-site.
5. Protect items from damage during transport and storage.
D. Removed and Reinstalled Items:
1. Clean and repair items to functional condition adequate for intended reuse.
2. Pack or crate items after cleaning and repairing. Identify contents of containers.
3. Protect items from damage during transport and storage.
4. Reinstall items in locations indicated. Comply with installation requirements for new materials and equipment. Provide connections, supports, and miscellaneous materials necessary to make item functional for use indicated.
E. Existing Items to Remain: Protect construction indicated to remain against damage and soiling during selective demolition. When permitted by Architect, items may be removed to a suitable, protected storage location during selective demolition and reinstalled in their original locations after selective demolition operations are complete.
3.5 CLEANING
A. Remove demolition waste materials from Project site and dispose of them in an EPA-approved construction and demolition waste landfill acceptable to authorities having jurisdiction.
1. Do not allow demolished materials to accumulate on-site.
2. Remove and transport debris in a manner that will prevent spillage on adjacent surfaces and areas.
B. Burning: Do not burn demolished materials.
C. Clean adjacent structures and improvements of dust, dirt, and debris caused by selective demolition operations.
Return adjacent areas to condition existing before selective demolition operations began.
END OF SECTION
SECTION 083100 - ACCESS DOORS AND PANELS
PART 1 - GENERAL
1.1 SECTION INCLUDES
A. Ceiling-mounted access units.
1.2 SUBMITTALS
A. Product Data: Provide sizes, types, finishes, hardware, scheduled locations, and details of adjoining work.
PART 2 - PRODUCTS
2.1 ACCESS DOORS AND PANELS ASSEMBLIES
A. Ceiling-Mounted Units:
1. Location: As indicated on drawings.
2. Size: 12 by 12 inches.
3. Door/Panel: Hinged, standard duty, with tool-operated spring or cam lock and no handle.
2.2 CEILING-MOUNTED ACCESS UNITS
A. Manufacturers:
1. Activar Construction Products Group, Inc. - JL Industries: www.activarcpg.com/#sle.
a. Insulated Fire-Rated Access Panel: Activar/JL Industries FD.
2. Babcock-Davis; B-IW Series -insulated, fire rated: www.babcockdavis.com/#sle.
B. Ceiling-Mounted Units: Factory-fabricated door and frame, fully assembled units with corner joints welded, filled and ground flush; square and without rack or warp; coordinate requirements with type of installation assembly being used for each unit.
1. Material: Steel.
2. Style: Recessed door panel for infill with wall/ceiling finish.
a. Gypsum Board Mounting Criteria: Use drywall bead type frame.
3. Door Style: Single thickness with rolled or turned in edges.
4. Frames: 16-gauge, 0.0598-inch minimum thickness.
5. Single Steel Sheet Door Panels: 20-gauge.
6. Insulation: Non-combustible mineral wool or glass fiber.
7. Primed and Factory Finish: Polyester powder coat; color White.
8. Hardware:
a. Hinges for Non-Fire-Rated Units: Concealed, constant force closure spring type.
b. Latch/Lock: Tamperproof tool-operated cam latch.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Verify that rough openings are correctly sized and located.
B. Begin installation only after substrates have been properly prepared, and if the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.
3.2 INSTALLATION
A. Install units in accordance with manufacturer's instructions.
B. Install frames plumb and level in openings, and secure units rigidly in place.
END OF SECTION
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
238608 / 80005
80005
C U s e rs \s w e h lin g
\D o c u m e n ts
\r e v it te m p \0
-A
R C
H
R s w e h lin g
.r v t
SMW
SMW
DJK
2/24/23
07310.034
A 01
ARCHITECTURAL SPECS
07310034- 2- A 01 ARCHITECTURAL SPECS
HVAC REPLACEMENT
JEWEL CAVE NATIONAL MONUMENT
CUSTER, SD
SECTION 06 10 00 - ROUGH CARPENTRY
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Nonstructural dimension lumber framing.
B. Sheathing.
C. Concealed wood blocking, nailers, and supports.
1.02 DELIVERY, STORAGE, AND HANDLING
A. General: Cover wood products to protect against moisture. Support stacked products to prevent deformation and to allow air circulation.
PART 2 PRODUCTS
2.01 GENERAL REQUIREMENTS
A. Dimension Lumber: Comply with PS 20 and requirements of specified grading agencies.
1. Species: Douglas Fir, unless otherwise indicated.
2. Lumber of other species or grades is acceptable provided structural and appearance characteristics are equivalent to or better than products specified.
2.02 DIMENSION LUMBER FOR CONCEALED APPLICATIONS
A. Sizes: Nominal sizes as indicated on drawings, S4S.
B. Moisture Content: S-dry or MC19.
C. Stud Framing (2 by 2 through 2 by 6 ):
1. Species: Allowed under referenced grading rules.
2. Grade: No. 2.
D. Miscellaneous Framing, Blocking, Nailers, Grounds, and Furring:
1. Lumber: S4S, No. 2 or Standard Grade.
2. Boards: Standard or No. 3.
2.03 ACCESSORIES
A. Fasteners and Anchors:
1. Metal and Finish: Hot-dipped galvanized steel complying with ASTM A153/A153M for high humidity and preservative-treated wood locations, unfinished steel elsewhere.
2.04 FACTORY WOOD TREATMENT
A. Treated Lumber and Plywood: Comply with requirements of AWPA U1 - Use Category System for wood treatments determined by use categories, expected service conditions, and specific applications.
1. Preservative-Treated Wood: Provide lumber and plywood marked or stamped by an ALSC-accredited testing agency, certifying level and type of treatment in accordance with AWPA standards.
PART 3 EXECUTION
3.01 PREPARATION
A. Coordinate installation of rough carpentry members specified in other sections.
3.02 INSTALLATION - GENERAL
A. Select material sizes to minimize waste.
B. Reuse scrap to the greatest extent possible; clearly separate scrap for use on site as accessory components, including: shims, bracing, and blocking.
C. Where treated wood is used on interior, provide temporary ventilation during and immediately after installation sufficient to remove indoor air contaminants.
3.03 BLOCKING, NAILERS, AND SUPPORTS
A. Provide framing and blocking members as indicated or as required to support finishes, fixtures, specialty items, and trim.
B. In framed assemblies that have concealed spaces, provide solid wood fireblocking as required by applicable local code, to close concealed draft openings between floors and between top story and roof/attic space; other material acceptable to code authorities may be used in lieu of solid wood blocking.
C. In walls, provide blocking attached to studs as backing and support for wall-mounted items, unless item can be securely fastened to two or more studs or other method of support is explicitly indicated.
3.04 CLEANING
A. Do not leave wood, shavings, sawdust, etc. on the ground or buried in fill.
B. Prevent sawdust and wood shavings from entering the storm drainage system.
END OF SECTION 06 10 00
DATE INITIAL
S S
SS
S
S
S
S
H
S
H
H
SECRETARY
STORAGE
OFFICE
OFFICE
OFFICE
OFFICE
WOMENS
MENS
VESTIBULE
MECH
WORKROOM
EXHIBIT ROOM
LOBBY
CORRIDOR
ELEVATOR
LOBBY
CORRIDOR
LOBBY EXHIBIT
PARK STORE
HALL
COURTYARD
CORRIDOR
117A
CORRIDOR
VESTIBULE
STAIR
GUIDES
ELEVATOR
HOISTWAY
D2 D2
D1
D1
D1
D1
D1
D1
D1
D3
STAIR
ENTRY
OFFICE
RESTROOM
STORAGE
MECH
ELEV
ELEV
D1
D2
D1
D5
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
238608 / 80005
80005
C U s e rs \s w e h lin g
\D o c u m e n ts
\r e v it te m p \0
-A
R C
H
R s w e h lin g
.r v t
SMW
SMW
DJK
2/24/23
07310.034
A001
DEMOLITION - CEILING
PLANS
07310034- 2- A001 DEMOLITION - CEILING PLANS
HVAC REPLACEMENT
JEWEL CAVE NATIONAL MONUMENT
CUSTER, SD
REF. DEMO NOTES ( ):DX
D1 REMOVE EXISTING ACOUSTIC CEILING TILE, GWB BACKING AND ATTIC
INSULATION, COORDINATE EXTENTS WITH MECHANICAL. ASSUME ATTIC
INSULATION CONTAINMENT.
D2 REMOVE EXISTING GWB CEILING AND ATTIC INSULATION, COORDINATE
EXTENTS WITH MECHANICAL. ASSUME ATTIC INSULATION CONTAINMENT.
D3 REMOVE EXISTING WALL AS REQUIRED FOR NEW MECHANICAL PIPES.
COORDINATE EXTENTS WITH MECHANICAL.
D5 REMOVE EXISTING WALL FOR MECHANICAL OUTSIDE AIR DUCT.
COORDINATE EXTENTS WITH MECHANICAL.
SCALE: 1/8" = 1'-0"
FIRST FLOOR - DEMOLITION REFLECTED CEILING PLAN
SCALE: 1/8" = 1'-0"
BASEMENT - DEMOLITION REFLECTED CEILING PLAN
DATE INITIAL
KEY PLAN NORTH
NORTH
STAIR
STORAGE
FAN ROOM
WORKROOM
D3
STAIR
ELEVATOR
MACHINE
ROOM
D4
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
238608 / 80005
80005
C U s e rs \s w e h lin g
\D o c u m e n ts
\r e v it te m p \0
-A
R C
H
R s w e h lin g
.r v t
SMW
SMW
DJK
2/24/23
07310.034
A002
DEMOLITION - CEILING
PLANS, DETAILS
07310034- 2- A002 DEMOLITION - CEILING PLANS, DETAILS
HVAC REPLACEMENT
JEWEL CAVE NATIONAL MONUMENT
CUSTER, SD
SCALE: 1/8" = 1'-0"
SECOND FLOOR (DEMOLITION CEILING PLAN)
REF. DEMO NOTES ( ):DX
NORTH
NORTH
D3 REMOVE EXISTING WALL AS REQUIRED FOR NEW MECHANICAL PIPES.
COORDINATE EXTENTS WITH MECHANICAL.
D4 REMOVE EXISTING GWB CEILING FOR NEW MECHANICAL EQUIPMENT,
COORDINATE EXTENTS WITH MECHANICAL.
DATE INITIAL
SCALE: 1/8" = 1'-0"
THIRD FLOOR (DEMOLITION CEILING PLAN)
STORAGE
WORKROOM
STAIR
FAN ROOM
ELEVATOR
MACHINE
ROOM
STAIR
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
238608 / 80005
80005
C U s e rs \s w e h lin g
\D o c u m e n ts
\r e v…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .