099600_SF_-_High-Performance_Coatings_0001.doc

DOC document 39 KB Posted

Attached to
BURLEY FIRE WAREHOUSE REMODEL
Solicitation number
140L2621R0005
Issued by

About this file

This document provides specifications for a high-performance coating system for the Burley Fire Warehouse Remodel project. The Bureau of Land Management seeks to apply a two-component polyurethane system to concrete horizontal surfaces within the warehouse, consisting of a prime coat and two intermediate coats of matching two-component polyurethane, and a topcoat of aliphatic polyurethane varnish in a gloss level of 6 or 7. Manufacturers for the coating system include Benjamin Moore, PPG Paints, and Sherwin-Williams, and products must be on the MPI Approved Products List and conform to their standards.

View the file

Other files

File Type Posted
Sol_140L2621R0005_Amd_0002.pdf PDF
DRAFT_L1416_Burley_Warehouse_ACM_Report_0001.pdf PDF
Sol_140L2621R0005_Amd_0001.pdf PDF
RFI_s_0001.docx DOCX document
Site_Tour_Sign_In_0001.pdf PDF
Burley_Fire_Warehouse_Drawings.pdf PDF
Burley_Fire_Warehouse_Specifications.pdf PDF
Sol_140L2621R0005.pdf PDF
SF-24_Bid_Bond.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION 099600 - HIGH-PERFORMANCE COATINGS

PART 1 - GENERAL

1.1 SUMMARY

A. Section includes surface preparation and the application of high-performance coating systems on the following substrate:

1. Interior Substrates:

a. Concrete, horizontal surfaces.

1.2 DEFINITIONS

A. MPI Gloss Level 5: 35 to 70 units at 60 degrees, according to ASTM D523.

B. MPI Gloss Level 6: 70 to 85 units at 60 degrees, according to ASTM D523.

C. MPI Gloss Level 7: More than 85 units at 60 degrees, according to ASTM D523.

1.3 ACTION SUBMITTALS

A. Product Data: For each type of product. Include preparation requirements and application instructions.

1. Include printout of current "MPI Approved Products List" for each product category specified, with the proposed product highlighted.

B. Samples: For each color and gloss of topcoat indicated.

1.4 QUALITY ASSURANCE

A. Mockups: Apply mockups of each coating system indicated to verify preliminary selections made under Sample submittals and to demonstrate aesthetic effects and set quality standards for materials and execution.

1. Government will select one surface to represent surfaces and conditions for application of coating system.

a. Floor: Provide samples of at least 100 sq. ft..

b. Other Items: Architect will designate items or areas required.

2. Final approval of color selections will be based on mockups.

a. If preliminary color selections are not approved, apply additional mockups of additional colors selected by Government at no added cost to Owner.

PART 2 - PRODUCTS

2.1 MANUFACTURERS

A. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

1. Benjamin Moore & Co.

2. PPG Paints.

3. Sherwin-Williams Company (The).

B. Products: Subject to compliance with requirements, provide one of the products per Interior High-Performance Coating Schedule for the coating category indicated.

2.2 HIGH-PERFORMANCE COATINGS, GENERAL

A. MPI Standards: Products shall comply with MPI standards indicated and shall be listed in its "MPI Approved Products Lists."

B. Material Compatibility:

1. Materials for use within each paint system shall be compatible with one another and substrates indicated, under conditions of service and application as demonstrated by manufacturer, based on testing and field experience.

2. For each coat in a paint system, products shall be recommended in writing by topcoat manufacturers for use in paint system and on substrate indicated.

3. Products shall be of same manufacturer for each coat in a coating system.

C. Colors: As selected by Government from manufacturer's full range.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine substrates and conditions, with Applicator present, for compliance with requirements for maximum moisture content and other conditions affecting performance of the Work.

B. Maximum Moisture Content of Substrates: When measured with an electronic moisture meter as follows:

1. Concrete: 12 percent.

C. Verify suitability of substrates, including surface conditions and compatibility with existing finishes and primers.

D. Proceed with coating application only after unsatisfactory conditions have been corrected.

1. Application of coating indicates acceptance of surfaces and conditions.

3.2 PREPARATION

A. Remove hardware, covers, plates, and similar items already in place that are removable and are not to be painted. If removal is impractical or impossible because of size or weight of item, provide surface-applied protection before surface preparation and painting.

1. After completing painting operations, use workers skilled in the trades involved to reinstall items that were removed. Remove surface-applied protection if any.

B. Clean substrates of substances that could impair bond of coatings, including dust, dirt, oil, grease, and incompatible paints and encapsulants.

1. Remove incompatible primers and reprime substrate with compatible primers or apply tie coat as required to produce coating systems indicated.

3.3 APPLICATION

A. Apply high-performance coatings according to manufacturer's written instructions and recommendations in "MPI Architectural Painting Specification Manual."

B. Apply coatings to produce surface films without cloudiness, spotting, holidays, laps, brush marks, runs, sags, ropiness, or other surface imperfections. Produce sharp glass lines and color breaks.

3.4 INTERIOR HIGH-PERFORMANCE COATING SCHEDULE

A. Concrete Substrates, Horizontal Surfaces.

1. Clear (Two-Component) Polyurethane System MPI INT 3.2K:

a. Prime Coat: Two-component polyurethane matching topcoat.

b. Intermediate Coat: Two-component polyurethane, matching topcoat.

c. Topcoat: Varnish, aliphatic polyurethane, two component (MPI Gloss Level 6 or MPI Gloss Level 7), MPI #78.

END OF SECTION 099600

JULY 2021

BURLEY FIRE WAREHOUSE REMODEL

HIGH-PERFORMANCE COATINGS

099600 - 1