This document contains a federal contract solicitation and related asbestos assessment findings for a building at Haskell Indian Nations University. The solicitation is for a fixed price construction project set aside for Indian Economic Enterprises to replace the HVAC system in Building 105 at HINU. Interested parties must attend the mandatory site visit on August 9, 2022 and submit their response package, including a response to the evaluation factors and price schedule, to the Bureau of Indian Education by August 26, 2022. The asbestos assessment findings indicate that 9 inches of floor tile and mastic in storage and an activity room require ongoing operations and maintenance due to their non-friable category 1 status. Inspections of the flooring must be conducted at least every six months.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Building Name & Number:
105 – Minoka
Haskell Indian Nations University
155 Indian Avenue
Lawrence, KS 66046-4800
Topic:
Asbestos
Assessment Findings & Action:
Category I – Non-Friable
· 9” Floor Tile/Mastic – Storage
· Suspect Material in Activity Room
Response Actions:
· Floor Tile/Mastic – Recommend Operations & Maintenance The Response Action for the 230 sq. ft. of 9” floor tile in the Minoka building shall be an Operations and Maintenance activity. The floor tile was assessed in the 3-Year Re-Inspection to be in undamaged condition. The floor tile shall have surveillance inspections conducted at least every six months and re-inspection as part of the AHERA 3-Year Re-Inspections. The floor tile shall be maintained utilizing workers who have had at a minimum 16 hours of AHERA Asbestos Maintenance Worker training as defined by the AHERA regulations. The floor tile shall be maintained in an undamaged condition until eventual removal.
· Prior July, 2005 report does not indicated tile under carpet in Activity Room. AOC recommends testing prior to any removal of this tile.
Guidance for Inspector:
Conduct follow-up 3-Year AHERA Re-Inspections to the previous asbestos inspection.
AHERA 3-Year Re-Inspection Conducted:
Inspector:
Alvin H. Stuke, Asbestos Management Planner
Certificate #:
7011030310MOMR10763
Date of Inspection:
September, 2010
AHERA Priority for Management Plan:
Suggest review of files for response actions and inspection results.