PROJECT LOCATION

VICINITY MAP

SHEET OF

United States Department of Agriculture

Forest Service

INDEX OF SHEETS

SHEET SHEET TITLE DATE

G-01 COVER SHEET 6/8/2020

G-02 GENERAL NOTES 6/8/2020

G-03 GENERAL SPECIFICATIONS 6/8/2020

G-04

ELECTRICAL, HARDWARE, AND PAINT

SPECIFICATIONS

6/8/2020

G-05 ELECTRICAL SPECIFICATIONS 6/8/2020

A-01 DEMO PLAN 6/8/2020

A-02 REMODEL LAYOUT NEW DIMENSIONS 6/8/2020

A-03 REMODEL FLOOR PLAN 6/8/2020

A-04 ROOM H ELEVATION VIEWS 6/8/2020

A-05 ROOM I ELEVATION VIEWS 6/8/2020

A-06 ROOM A ELEVATION VIEWS 6/8/2020

A-07 NEW FLOORING 6/8/2020

A-08 FINISH AND LIGHTING SCHEDULE 6/8/2020

A-09

HARDWARE, DECOR, AND EQUIPMENT

SCHEDULE

6/8/2020

A-10

HARDWARE, DECOR, AND EQUIPMENT

SCHEDULE (CONTINUED)

6/8/2020

A-11 DOOR SCHEDULE 6/8/2020

A-12 CONSTRUCTION DETAILS 6/8/2020

E-01 NEW LIGHTING PLAN 6/8/2020

ADDRESS:

Southeast Corner of Pima Street and Yaqui Street, Springerville, AZ 85938

LAT: 34.130126° / LONG: -109.279609°

DATE

RECOMMENDED BY:

APPROVED:

FOREST ENGINEER

FOREST SUPERVISOR

DISTRICT RANGER DATE

DIRECTOR OF ENGINEERING

DATE

RO FACILITIES PROGRAM MANAGER

DATE

DATE

SOUTH YAQUI

HOUSE REMODEL

STATE OF ARIZONA

APACHE COUNTY

APACHE-SITGREAVES NATIONAL FORESTS

R3 SOUTHWESTERN REGION

SPRINGERVILLE, AZ

S. YAQUI HOUSE

PROJECT LOCATION

updated 06/08/2020

DRAWING TITLE

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

6/8 /20

:1

4 R

IC

HA

RD

RP

OL

AN

CO

C :\U

SE

RS

\R

IC

HA

RD

RP

OL

AN

CO

\D

ES

KT

OP

\R P\

PR

OJ

EC

TS

\Y

AQ

UI

H

OU

SE

R

EN

OV

AT

IO

N

AN

D

FL

OO

RI

NG

\1_

PR

E-

SO

LI

CI

TA

TI

ON

\D

RA

W

IN

GS

\E

XH

IB

IT

XX

_D

RA

W

IN

GS

.D W

G;

R3

SOUTHWESTERN REGION

SOUTH YAQUI HOUSE

REMODEL

APACHE-SITGREAVES

NATIONAL FORESTS

SPRINGERVILLE RANGER

DISTRICT

GENERAL NOTES

06/08/2020

R.POLANCO

R.POLANCO

C.MILLER

G-02

018002

INDEX OF DRAWINGS

ARCHITECTURAL LEGEND

GENERAL NOTES

W1 D1

WORK SUMMARY

DEMO AND CONSTRUCTION SEQUENCE

A

AutoCAD SHX Text

PROJECT NAME

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text A-01

AutoCAD SHX Text

DISCIPLINE

AutoCAD SHX Text A - ARCHITECTURE C - CIVIL E - ELECTRICAL G - GENERAL L - LANDSCAPE M - MECHANICAL

AutoCAD SHX Text

SHEET NUMBER WITHIN SERIES

AutoCAD SHX Text

ANNOTATION CALLOUTS/SYMBOLS

AutoCAD SHX Text A-01

AutoCAD SHX Text A-01

AutoCAD SHX Text A-01

AutoCAD SHX Text

INTERIOR ELEVATION

AutoCAD SHX Text

SHEET NUMBER WHERE SECTION/DETAIL IS DRAWN

AutoCAD SHX Text

EXTERIOR ELEVATION

AutoCAD SHX Text

SHEET NUMBER WHERE SECTION/DETAIL IS DRAWN

AutoCAD SHX Text

SECTION

AutoCAD SHX Text

SHEET NUMBER WHERE SECTION/DETAIL IS DRAWN

AutoCAD SHX Text

AutoCAD SHX Text

KEYED NOTE

AutoCAD SHX Text

WINDOW NUMBER

AutoCAD SHX Text

DOOR NUMBER

AutoCAD SHX Text

WALL, FLOOR, AND CEILING SYMBOLS

AutoCAD SHX Text

1. THE "CONTRACTOR" AS REFERENCED HEREIN REFERS TO THE THE "CONTRACTOR" AS REFERENCED HEREIN REFERS TO THE COMPANY OR PERSON PERFORMING THE INSTRUCTED WORK. 2. THE "COR" AS REFERENCED HEREIN REFERS TO THE THE "COR" AS REFERENCED HEREIN REFERS TO THE CONTRACTING OFFICER'S REPRESENTATIVE. 3. CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS AS CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS AS REQUIRED BY LOCAL JURISDICTIONS, SPECIFICALLY TOWN BUILDING PERMITS AND ADEQ REQUIRED NESHAP REPORTING REQUIREMENTS AS A RESULT OF DEMOLITION ACTIVITIES. 4. CONSTRUCTION SHALL BE PER THE LATEST VERSION OF THE CONSTRUCTION SHALL BE PER THE LATEST VERSION OF THE APPLICABLE ENERGY, ELECTRICAL, PLUMBING, AND BUILDING CODES, OR THE CONSTRUCTION PLANS, WHICHEVER IS MORE STRINGENT. 5. FURNISH AND INSTALL ALL REQUIRED TO COMPLETE THE FURNISH AND INSTALL ALL REQUIRED TO COMPLETE THE PROJECT AS SHOWN HEREIN. IF THERE IS AN OMISSION ON THE PLANS, SUCH OMISSION SHALL NOT BE CONSTRUED TO MEAN THAT THE CONTRACTOR IS NOT REQUIRED TO FURNISH OR PROVIDE ALL THAT IS NECESSARY FOR COMPLETE AND OPERABLE FEATURES OF WORK. 6. ANY CHANGES TO THE DESIGN AS SHOWN MUST BE REVIEWED ANY CHANGES TO THE DESIGN AS SHOWN MUST BE REVIEWED AND APPROVED BY THE CONTRACTING OFFICER BEFORE CHANGES ARE MADE. THIS INCLUDES CHANGES REQUEST BY THE CONTRACTOR AND SUBCONTRACTORS. 7. THE CONTRACTOR SHALL CONTACT THE APPROPRIATE BLUE THE CONTRACTOR SHALL CONTACT THE APPROPRIATE BLUE STAKE TO MARK AND IDENTIFY UNDERGROUND UTILITIES PRIOR TO EXCAVATION.. 8. THE LOCATIONS AND MEASUREMENTS HEREIN ARE APPROXIMATE. THE LOCATIONS AND MEASUREMENTS HEREIN ARE APPROXIMATE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ALL MEASUREMENTS PRIOR TO ORDERING MATERIALS. 9. CONTRACTORS WORKING WITHIN THE PROJECT BOUNDARIES ARE CONTRACTORS WORKING WITHIN THE PROJECT BOUNDARIES ARE RESPONSIBLE FOR COMPLIANCE WITH ALL JURISDICTIONAL SAFETY LAWS AND REGULATIONS. 10. WHEN A PRODUCT IS SPECIFIED, AN APPROVED EQUAL MAY BE WHEN A PRODUCT IS SPECIFIED, AN APPROVED EQUAL MAY BE SUBSTITUTED SO LONG AS IT MEETS ALL TECHNICAL AND FINISH CRITERIA OF THE SPECIFIED PRODUCT. 11. THERE IS MINIMAL FURNITURE IN THE HOUSE (REFRIGERATORS, THERE IS MINIMAL FURNITURE IN THE HOUSE (REFRIGERATORS, BED FRAMES, ETC.). CONTRACTOR IS RESPONSIBLE FOR MOVING AROUND EXISTING FURNISHINGS TO ACCOMPLISH THE WORK. 12. FOR APPLIANCE INSTALLATION, ALL REQUIRED ELECTRICAL AND FOR APPLIANCE INSTALLATION, ALL REQUIRED ELECTRICAL AND PLUMBING CONNECTIONS, WIRING, PIPING, ETC. ARE INCIDENT TO THE WORK AND SHALL BE INCLUDED IN THE COST TO DO THE WORK.

AutoCAD SHX Text

1. WHEN THE TERMS "REMOVE", "DISPOSE", "DEMOLISH", OR WHEN THE TERMS "REMOVE", "DISPOSE", "DEMOLISH", OR "DEMO" ARE USED, DISPOSE LEGAL OFFSITE IN ACCORDANCE WITH APPLICABLE LOCAL, COUNTY, STATE, AND FEDERAL JURISDICTIONS. ANY SALVAGE VALUE AS A RESULT OF THE WORK SHALL BE INCLUDED IN THE INITIAL BIDDING DOCUMENT. 2. WHEN A FEATURE OF WORK INCLUDES DEMOLITION (SUCH AS WHEN A FEATURE OF WORK INCLUDES DEMOLITION (SUCH AS DOORS, FRAMES, LIGHTS, VENTS, RECESSED FIXTURES, ETC.), PATCH, AND REPAIR DRYWALL AFTER DEMOLITION ACTIVITIES ARE COMPLETE, TO INCLUDE ANY REQUIRED WOOD STUD FRAMING SECTIONS FOR THE VOIDS. 3. DEMO IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL EPA DEMO IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL EPA REGULATIONS WHEN ASBESTOS-CONTAINING MATERIALS AND LEAD-BASED PAINT ARE PRESENT. REFER TO CERTIFIED SAMPLING AND TESTING REPORT. 4. BUILDING WILL BE VACANT DURING CONSTRUCTION ACTIVITIES. BUILDING WILL BE VACANT DURING CONSTRUCTION ACTIVITIES. 5. PROVIDE FINAL CLEANING OF HOUSE PRIOR TO CONTRACTING PROVIDE FINAL CLEANING OF HOUSE PRIOR TO CONTRACTING OFFICER ACCEPTANCE.

AutoCAD SHX Text THE GOVERNMENT INTENDS TO AWARD A REMODEL PROJECT ON THE SPRINGERVILLE RANGER DISTRICT, SOUTH YAQUI HOUSE. THE PROJECT INCLUDES REMOVING ALL FLOORING (TILE CONSIST OF ASBESTOS), BASEBOARD, BATHROOM FIXTURES AND ACCESSORIES, AND DOOR/WALL DEMOLITION. REMODEL WORK INCLUDES NEW VINYL FLOORING, ADDING AN ACCESSIBLE BATHROOM, REPLACE DOORS, NEW WALLS, BATH/SHOWER UNITS, PELLET STOVE INSTALLATION, FULL KITCHEN REMODEL, AND LIGHTING. OPTION ITEMS INCLUDE REPLACING WINDOWS AND APPLIANCE REPLACEMENT.

AutoCAD SHX Text

ROOM NUMBER

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

6/8 /20

:1

4 R

IC

HA

RD

RP

OL

AN

CO

C :\U

SE

RS

\R

IC

HA

RD

RP

OL

AN

CO

\D

ES

KT

OP

\R P\

PR

OJ

EC

TS

\Y

AQ

UI

H

OU

SE

R

EN

OV

AT

IO

N

AN

D

FL

OO

RI

NG

\1_

PR

E-

SO

LI

CI

TA

TI

ON

\D

RA

W

IN

GS

\E

XH

IB

IT

XX

_D

RA

W

IN

GS

.D W

G;

R3

SOUTHWESTERN REGION

SOUTH YAQUI HOUSE

REMODEL

APACHE-SITGREAVES

NATIONAL FORESTS

SPRINGERVILLE RANGER

DISTRICT

GENERAL

SPECIFICATIONS

06/08/2020

R.POLANCO

R.POLANCO

C.MILLER

G-03

018003

SPECIFICATIONS

AutoCAD SHX Text

PROJECT NAME

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

1. PLUMBING: FOR ALL NEW PLUMBING, USE THE LATEST PLUMBING: FOR ALL NEW PLUMBING, USE THE LATEST UNIVERSAL PLUMBING CODE (UPC). AT A MINIMUM: 1.1. INSTALL P-TRAPS FOR ALL NEW PLUMBING FIXTURE INSTALL P-TRAPS FOR ALL NEW PLUMBING FIXTURE LOCATIONS. CONTRACTOR IS RESPONSIBILE FOR DETERMINING SIZE AND SPACE NEEDED AND INSTALLING AS REQUIRED. 1.2. INSTALL ADEQUATE VENTING FOR ALL NEW PLUMBING INSTALL ADEQUATE VENTING FOR ALL NEW PLUMBING FIXTURES, INCLUDING PENETRATION(S) AS REQUIRED. SUBMIT SHOP DRAWINGS FOR APPROVAL. 1.3. INSTALL 4" PVC SEWER DRAIN FOR NEW LOCATIONS INSTALL 4" PVC SEWER DRAIN FOR NEW LOCATIONS OF PLUMBING FIXTURES AND SHOWER UNITS 1.4. FOR ALL PLUMBING AND FIXTURE PENETRATIONS FOR ALL PLUMBING AND FIXTURE PENETRATIONS THROUGH WALLS IN BATHROOMS AND SHOWER, SEAL WATER-TIGHT WITH WATER-PROOF CAULKING/SEALANT. 1.5. INCLUDE ALL VALVES, CONNECTIONS, ETC. FOR NEW INCLUDE ALL VALVES, CONNECTIONS, ETC. FOR NEW PLUMBING ASSEMBLIES. 2. GYPSUM BOARD, JOINT COMPOUND, AND INSULATION: GYPSUM BOARD, JOINT COMPOUND, AND INSULATION: 2.1. PROVIDE ASBESTOS-FREE MATERIALS. PROVIDE ASBESTOS-FREE MATERIALS. 2.2. PROVIDE GYP. BOARD WITH TAPERED EDGES AND PROVIDE GYP. BOARD WITH TAPERED EDGES AND JOINT COMPOUND CONFORMING TO ASTM C1396 C475, RESPECTIVELY. APPLY BOARDS TO FRAMING AND FURRING MEMBERS IN ACCORDANCE TO ASTM C840 OR GYPSUM ASSOCIATION (GA) 216. DO NOT FORCE PANELS IN PLACE, AND NEATLY FIT ABUTTING END AND EDGE JOINTS. CUT BOARD TO MAKE NEAT, CLOSE, AND TIGHT JOINTS AROUND OPENINGS. FOR VERTICAL SURFACES, PROVIDE PANELS IN ONE-CONTINUOUS LENGTH TO REACH FULL HEIGHT. 2.3. TREAT EDGES OF CUTOUTS FOR PLUMBING PIPES, TREAT EDGES OF CUTOUTS FOR PLUMBING PIPES, SCREW HEADS, AND JOINTS WITH WATER-RESISTANT COMPOUND AS RECOMMENDED BY THE MANUFACTURER. 2.4. TAPE AND FINISH GYP. BOARD IN ACCORDANCE WITH TAPE AND FINISH GYP. BOARD IN ACCORDANCE WITH ASTM C840, GA-214, AND GA-216. PROVIDE JOINT FASTENER DEPRESSION AND CORNER TREATMENT. TOOL JOINTS SMOOTHLY TO MINIMIZE SANDING AND DUST. USE SETTING OR HARDENING TYPE COMPOUNDS ONLY WITH CONVENTIONAL DRYING TYPE JOINT COMPOUNDS. 2.5. INSTALL MINIMUM 3 " SOUND ATTENUATION INSULATION. INSTALL MINIMUM 3 " SOUND ATTENUATION INSULATION. 12" SOUND ATTENUATION INSULATION. DELIVER MATERIALS TO SITE IN ORIGINAL SEALED WRAPPING BEARING MANUFACTURER'S NAME AND BRAND DESIGNATION, TYPE, GRADE, R-VALUE, AND CLASS. 3. DOORS AND FRAMES DOORS AND FRAMES 3.1. DOORS MUST BE 1 " THICK, UNLESS OTHERWISE DOORS MUST BE 1 " THICK, UNLESS OTHERWISE 34" THICK, UNLESS OTHERWISE NOTED. FORM FRAMES TO SIZES AND SHAPES INDICATED, WITH KNOCK-DOWN FIELD-ASSEMBLED 3.2. CORNERS. ENSURE ALL DOOR JAMBS ARE PROPERLY CORNERS. ENSURE ALL DOOR JAMBS ARE PROPERLY FRAMED AND REINFORCED FOR STRUCTURAL RIGIDITY AND PROPER DOOR OPERATION. ALL DOORS AND FRAMES MUST BE THOROUGHLY CLEANED, CHEMICALLY TREATED AND FACTORY PRIMED WITH A RUST INHIBITING COATING (FOR STEEL DOORS). 3.3. PROVIDE FINISHED DOORS AND FRAMES FREE FROM PROVIDE FINISHED DOORS AND FRAMES FREE FROM DEFECTS, WAVES, SCRATCHES, CUTS, DENTS, RIDGES, HOLES, WARP, AND BUCKLE. 3.4. INSTALL WALL-MOUNT DOOR STOPS FOR ALL NEW AND INSTALL WALL-MOUNT DOOR STOPS FOR ALL NEW AND EXISTING DOORS. 3.5. 6-PANEL, COMPOSITE DOORS, ULTRA-WHITE 6-PANEL, COMPOSITE DOORS, ULTRA-WHITE 4. FRAMING FRAMING 4.1. PROVIDE 2"X4" WOOD STUD FRAMING, DOUGLAS FIR. PROVIDE 2"X4" WOOD STUD FRAMING, DOUGLAS FIR. 4.2. USE WWPA G-5 STANDARD GRADING RULES, STANDARD USE WWPA G-5 STANDARD GRADING RULES, STANDARD LIGHT FRAMING OR NO. 3 STRUCTURAL LIGHT FRAMING (STUD GRADE FOR 2X4 NOMINAL SIZE, 10 FEET AND SHORTER). 4.3. INSTALL IN ACCORDANCE WITH THE NATIONAL INSTALL IN ACCORDANCE WITH THE NATIONAL ASSOCIATED OF HOME BUILDERS (NAHB) ADVANCED FRAMING TECHNIQUES: OPTIMUM VALUE ENGINEERING, UNLESS OTHERWISE SPECIFIED. 4.4. FIT FRAMING LUMBER AND OTHER ROUGH CARPENTRY, FIT FRAMING LUMBER AND OTHER ROUGH CARPENTRY, SET ACCURATELY TO THE REQUIRED LINES AND LEVELS, AND SECURE IN PLACE IN A RIGID MANNER. 4.5. PROVIDE AS NECESSARY FOR THE PROPER PROVIDE AS NECESSARY FOR THE PROPER COMPLETION OF THE WORK ALL FRAMING MEMBERS NOT INDICATED OR SPECIFIED. 4.6. PROVIDE SILLS (PRESSURE TREATED ON CONCRETE) AT PROVIDE SILLS (PRESSURE TREATED ON CONCRETE) AT ALL NEW WALL LOCATIONS. SET LEVEL AND SQUARE AND WEDGE WITH STEEL OR SLATE SHIMS. ANCHOR SILLS TO FOUNDATION. PROVIDE AT LEAST TWO BOLTS FOR EACH STILL MEMBER. PROVIDE MINIMUM ONE ON BOTTOM AND TWO TOP, CUT FROM SIMILAR DIMENSION LUMBER. 5. FLOORING FLOORING 5.1. FURNISH ALL MISCELLANEOUS MATERIALS, INCLUDING FURNISH ALL MISCELLANEOUS MATERIALS, INCLUDING REQUIRED FOR FLOORING INSTALLATION. 5.2. STORE ALL MATERIALS IN ORIGINAL PROTECTIVE STORE ALL MATERIALS IN ORIGINAL PROTECTIVE PACKAGING IN A SAFE, DRY, AND, CLEAN LOCATION. REPLACE DEFECTIVE OR DAMAGED MATERIALS. 5.3. FLOORING SUBSTRATE PREPARATION FLOORING SUBSTRATE PREPARATION 5.3.1. AFTER DEMOLITION, REPAIR AND PATCH EXISTING AFTER DEMOLITION, REPAIR AND PATCH EXISTING SUBFLOORING SURFACE TO ENSURE NEW FLOORING IS SOUND, FIRM, AND LEVEL. 5.3.2. USE LEVELING AND PATCHING COMPOUNDS AS USE LEVELING AND PATCHING COMPOUNDS AS RECOMMENDED BY THE FLOORING MANUFACTURER. 5.3.3. BROOM AND VACUUM CLEAN SUBSTRATES TO BE BROOM AND VACUUM CLEAN SUBSTRATES TO BE COVERED IMMEDIATELY BEFORE INSTALLING NEW FLOORING. OBTAIN COR APPROVAL OF SUBSTRATE SURFACE PRIOR TO INSTALLING FLOORING. 5.4. FOR BATHROOM AREAS, FLOORING MUST BE RATED FOR BATHROOM AREAS, FLOORING MUST BE RATED GREATER THAN OR EQUAL TO 0.42 DYNAMIC COEFFICIENT OF FRICTION (DCOF) IN ACCORDANCE WITH ANSI A137.1, SECTION 9.6. 5.5. PROVIDE TWO (2) EXTRA CASES OF VINYL FLOORING PROVIDE TWO (2) EXTRA CASES OF VINYL FLOORING TO COR. 5.5.0.1.1. 6. WINDOWS WINDOWS 6.1. FOR NEW WINDOWS, INSTALL NEW FRAME TO MATCH FOR NEW WINDOWS, INSTALL NEW FRAME TO MATCH COLOR AND MATERIAL OF EXISTING WINDOWS (UNLESS OTHERWISE INDICATED), AND DOUBLE GLAZING WITH LOCKING HANDLES AND SCREENS LOCATED ON THE SLIDING SIDE OF THE WINDOW. 6.2. WINDOWS MUST MEET ENERGY STAR CERTIFICATION FOR WINDOWS MUST MEET ENERGY STAR CERTIFICATION FOR NORTHERN CLIMATE ZONE, AND RECOMMENDED CAVITY WIDTH FOR "LOW E" STANDARDS, AND FILLED WITH INSULATING LAYER (DEHYDRATED AIR). CAVITIES FILLED WITH AN INERT GAS, SUCH AS ARGON, ARE NOT PERMITTED.

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

6/8 /20

:1

4 R

IC

HA

RD

RP

OL

AN

CO

C :\U

SE

RS

\R

IC

HA

RD

RP

OL

AN

CO

\D

ES

KT

OP

\R P\

PR

OJ

EC

TS

\Y

AQ

UI

H

OU

SE

R

EN

OV

AT

IO

N

AN

D

FL

OO

RI

NG

\1_

PR

E-

SO

LI

CI

TA

TI

ON

\D

RA

W

IN

GS

\E

XH

IB

IT

XX

_D

RA

W

IN

GS

.D W

G;

R3

SOUTHWESTERN REGION

SOUTH YAQUI HOUSE

REMODEL

APACHE-SITGREAVES

NATIONAL FORESTS

SPRINGERVILLE RANGER

DISTRICT

EQUIPMENT,

HARDWARE, & PAINT

SPECIFICATIONS

06/08/2020

R.POLANCO

R.POLANCO

C.MILLER

G-04

018004

SPECIFICATIONS

AutoCAD SHX Text

PROJECT NAME

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

1. EQUIPMENT AND HARDWARE EQUIPMENT AND HARDWARE 1.1. INSTALL PER THE MANUFACTURER'S RECOMMENDATION. INSTALL PER THE MANUFACTURER'S RECOMMENDATION. 1.2. GRAB BARS GRAB BARS 1.2.1. SHALL NOT ROTATE WITHIN THEIR FITTINGS. SHALL NOT ROTATE WITHIN THEIR FITTINGS. 1.2.2. ALLOWABLE STRESSES SHALL NOT BE EXCEEDED ALLOWABLE STRESSES SHALL NOT BE EXCEEDED FOR MATERIALS USED WHEN A VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS IS APPLIED AT ANY POINT ON THE GRAB BAR, FASTENER, MOUNTING DEVICE, OR SUPPORTING STRUCTURE. 1.2.3. INSTALL BACKING, FRAMING, OR OTHER INSTALL BACKING, FRAMING, OR OTHER SUPPORT, AS NEEDED, FOR STRUCTURAL STRENGTH AND RIGIDITY. 1.2.4. CLOSETS, DOORS, AND BLINDS CLOSETS, DOORS, AND BLINDS 1.2.4.1. SPECIFIED MAKE AND MODEL ARE NOT SPECIFIED MAKE AND MODEL ARE NOT INTENDED TO BE THE EXACT SIZE NEEDED. INSTALL IN SPACE AS FIELD MEASURED. 1.2.5. BATHROOM FIXTURES AND ACCESSORIES BATHROOM FIXTURES AND ACCESSORIES 1.2.5.1. SEAL WATER TIGHT AROUND ALL ITEMS. SEAL WATER TIGHT AROUND ALL ITEMS. 1.3. COUNTERTOPS COUNTERTOPS 1.3.1. WRAP BACKSPLASH AT ALL WALL LOCATIONS. WRAP BACKSPLASH AT ALL WALL LOCATIONS. 1.3.2. 3/8" DOUBLE RADIUS EDGING 3/8" DOUBLE RADIUS EDGING 1.3.3. FOR COUNTERTOPS EXTENDING FOR SEATING, FOR COUNTERTOPS EXTENDING FOR SEATING, INSTALL BRACING UNDER COUNTERTOP AS REQUIRED. 1.4. CASEWORK CASEWORK 1.4.1. CABINETS SHALL HAVE TWO ADJUSTABLE CABINETS SHALL HAVE TWO ADJUSTABLE SHELVES PER CABINET. 1.4.1.1. NOT APPLICABLE FOR BATHROOM AREAS. NOT APPLICABLE FOR BATHROOM AREAS. 1.4.2. SOFT CLOSED DRAWERS AND CABINET DOORS. SOFT CLOSED DRAWERS AND CABINET DOORS. 1.4.3. FULL EXTENSION DRAWERS. FULL EXTENSION DRAWERS. 1.4.4. SOLID MAPLE DOVE TAIL DRAWER BOXES. SOLID MAPLE DOVE TAIL DRAWER BOXES. 1.4.5. INSTALL 4-INCH VERTICAL, RECESSED TOE KICKS INSTALL 4-INCH VERTICAL, RECESSED TOE KICKS AT ALL LOCATIONS. 1.4.6. DOOR STYLES DOOR STYLES 1.4.6.1. KITCHEN - HIGHLAND DOOR STYLE KITCHEN - HIGHLAND DOOR STYLE 1.4.6.2. BATHROOMS - MILL CREEK DOOR STYLE BATHROOMS - MILL CREEK DOOR STYLE 2. INTERIOR PAINTING INTERIOR PAINTING 2.1. PREPARATION PREPARATION 2.1.1. COMPLY WITH RECOMMENDATIONS IN THE MASTER COMPLY WITH RECOMMENDATIONS IN THE MASTER PAINTER'S INSTITUTE (MPI) "MPI ARCHITECTURAL PAINTING SPECIFICATION MANUAL" APPLICABLE TO SUBSTRATES INDICATED. 2.1.2. REMOVE HARDWARE, LIGHTING FIXTURES, AND REMOVE HARDWARE, LIGHTING FIXTURES, AND SIMILAR ITEMS THAT ARE NOT TO BE PAINTED. MASK ITEMS THAT CANNOT BE REMOVED. REINSTALL ITEMS IN EACH AREA AFTER PAINTING IS COMPLETE. 2.1.3. REMOVE ALL WALL AND CEILING HOOKS, REMOVE ALL WALL AND CEILING HOOKS, FASTENERS, NAILS, ETC. AND PATCH DAMAGED AREAS PRIOR TO PAINT. 2.1.4. CLEAN AND PREPARE SURFACES IN AN AREA CLEAN AND PREPARE SURFACES IN AN AREA BEFORE BEGINNING PAINTING IN THAT AREA. SCHEDULE PAINTING SO CLEANING OPERATIONS WILL NOT DAMAGE NEWLY PAINTED SURFACES. 2.1.5. OBTAIN COR APPROVAL OF PREPPED INTERIOR OBTAIN COR APPROVAL OF PREPPED INTERIOR PRIOR TO PROCEEDING WITH PRIMER AND PAINT. 2.2. PAINT EXPOSED NEW AND EXISTING SURFACES, PAINT EXPOSED NEW AND EXISTING SURFACES, UNLESS OTHERWISE INDICATED. 2.2.1. DO NOT PAINT PRE-FINISHED ITEMS. DO NOT PAINT PRE-FINISHED ITEMS. 2.3. APPLY PAINTS TO PRODUCE SURFACE FILMS WITHOUT APPLY PAINTS TO PRODUCE SURFACE FILMS WITHOUT CLOUDINESS, SPOTTING, HOLIDAYS, LAPS, BRUSH MARKS, ROLLER TRACKING, RUNS, SAGS, ROPINESS, OR OTHER SURFACE IMPERFECTIONS. CUT IN SHARP LINES AND COLOR BREAKS 2.4. IF UNDERCOATS OR OTHER CONDITIONS SHOW IF UNDERCOATS OR OTHER CONDITIONS SHOW THROUGH TOPCOAT, APPLY ADDITIONAL COATS UNTIL CURED FILM HAS A UNIFORM PAINT FINISH, COLOR, AND APPEARANCE. 2.5. FINAL FINISH FINAL FINISH 2.5.1. GLOSS LEVEL 2, INSTITUTIONAL LOW-ODOR/VOC GLOSS LEVEL 2, INSTITUTIONAL LOW-ODOR/VOC LATEX, ONE COAT OVER LOW-ODOR/VOC PRIMER/SEALER, MPI INT 9.2.M. 2.5.1.1. NON-ACCENT WALLS AND CEILINGS: BEHR NON-ACCENT WALLS AND CEILINGS: BEHR CAMEO WHITE, MQ3-32. 2.5.1.2. ACCENT WALLS: BEHR MOCHA LIGHT, ACCENT WALLS: BEHR MOCHA LIGHT, BWC-24. 2.5.2. FOR UNFINISHED (PRIMED) CLOSET AND FOR UNFINISHED (PRIMED) CLOSET AND INTERIOR DOORS, PAINT BEHR ULTRA PURE WHITE. 3. EXTERIOR PAINTING EXTERIOR PAINTING 3.1. PREPARATION PREPARATION 3.1.1. REMOVE LOSE PAINT, DEBRIS, ETC. REMOVE LOSE PAINT, DEBRIS, ETC. 3.1.2. RE-CAULK EXTERIOR TRIM AS NEEDED, RE-CAULK EXTERIOR TRIM AS NEEDED, INCLUDING WINDOWS, DOORS, ETC. 3.1.3. PATCH HOLES AS NEEDED. PATCH HOLES AS NEEDED. 3.1.4. SAND AND CLEAN SURFACES RECEIVING PRIMER SAND AND CLEAN SURFACES RECEIVING PRIMER AND PAINT. 3.1.5. COMPLY WITH SECTION 2.1, "INTERIOR PAINTING COMPLY WITH SECTION 2.1, "INTERIOR PAINTING - PREPARATION," AS APPLICABLE. 3.1.6. OBTAIN COR APPROVAL OF PREPPED EXTERIOR OBTAIN COR APPROVAL OF PREPPED EXTERIOR PRIOR TO PROCEEDING WITH PRIMER AND PAINT. 3.2. COMPLY WITH SECTIONS 1.3 AND 1.4 UNDER COMPLY WITH SECTIONS 1.3 AND 1.4 UNDER INTERIOR PAINTING FOR APPLICATION. 3.3. DO NOT PAINT OVER ROOF METAL/FLASHING. DO NOT PAINT OVER ROOF METAL/FLASHING. 3.4. FINAL FINISH FINAL FINISH 3.4.1. SATIN FINISH, LATEX, TWO COATS OVER LATEX SATIN FINISH, LATEX, TWO COATS OVER LATEX PRIMER: MPI EXT 6.3L. 3.4.1.1. WALLS (INCLUDING SOFFIT): BEHR MESA WALLS (INCLUDING SOFFIT): BEHR MESA TAUPE, PPU5-14. 3.4.1.2. TRIM (AROUND WINDOWS, DOORS): BEHR TRIM (AROUND WINDOWS, DOORS): BEHR CHOCOLATE SWIRL, PPU5-18.

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

6/8 /20

:1

4 R

IC

HA

RD

RP

OL

AN

CO

C :\U

SE

RS

\R

IC

HA

RD

RP

OL

AN

CO

\D

ES

KT

OP

\R P\

PR

OJ

EC

TS

\Y

AQ

UI

H

OU

SE

R

EN

OV

AT

IO

N

AN

D

FL

OO

RI

NG

\1_

PR

E-

SO

LI

CI

TA

TI

ON

\D

RA

W

IN

GS

\E

XH

IB

IT

XX

_D

RA

W

IN

GS

.D W

G;

R3

SOUTHWESTERN REGION

SOUTH YAQUI HOUSE

REMODEL

APACHE-SITGREAVES

NATIONAL FORESTS

SPRINGERVILLE RANGER

DISTRICT

ELECTRICAL

SPECIFICATIONS

06/08/2020

R.POLANCO

R.POLANCO

C.MILLER

G-05

018005

SPECIFICATIONS

AutoCAD SHX Text

PROJECT NAME

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

1. ELECTRICAL ELECTRICAL 1.1. GENERAL GENERAL 1.1.1. LOCATIONS AND REQUIREMENTS OUTLINED HEREIN LOCATIONS AND REQUIREMENTS OUTLINED HEREIN ARE CONSIDERED APPROXIMATE. CONTRACTOR IS REQUIRED TO COMPLY WITH THE LATEST VERSION OF NFPA 70 FOR PERFORMING ALL ELECTRICAL WORK. RELOCATE ELECTRICAL LOCATIONS AS REQUIRED TO MEET CODE. 1.1.2. UPDATE EXISTING CIRCUIT BREAKER PANELS WITH UPDATE EXISTING CIRCUIT BREAKER PANELS WITH NEW LAMINATED LABELING. TEST AND VERIFY EXISTING CIRCUITS TO ACCURATE UPDATE CIRCUIT BREAKER LABELING. 1.1.3. GROUND AND BOND, AS REQUIRED BY NFPA 70, GROUND AND BOND, AS REQUIRED BY NFPA 70, ALL NEW ELECTRICAL WORK. 1.2. LOW VOLTAGE ELECTRICAL POWER CONDUCTORS AND LOW VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES 1.2.1. USE PULLING MEANS, INCLUDING FISH TABLE, USE PULLING MEANS, INCLUDING FISH TABLE, CABLE, ROPE, AND BASKET-WEAVE WIRE/CABLE GRIPS, THAT WILL NOT DAMAGE CABLES OR RACEWAY. USE MANUFACTURER-APPROVED PULLING COMPOUND OR LUBRICANT WHERE NECESSARY. 1.2.2. MAKE SPLICES, TERMINATIONS, AND TAPS THAT MAKE SPLICES, TERMINATIONS, AND TAPS THAT ARE COMPATIBLE WITH CONDUCTOR MATERIAL. 1.2.3. INSTALL CONDUCTOR AT EACH OUTLET, WITH AT INSTALL CONDUCTOR AT EACH OUTLET, WITH AT LEAST 6 INCHES OF SLACK. 1.2.4. INSTALL SLEEVES AND SLEEVE SEALS AT INSTALL SLEEVES AND SLEEVE SEALS AT PENETRATIONS OF EXTERIOR FLOOR AND WALL ASSEMBLIES. 1.2.5. TIGHTEN ELECTRICAL CONNECTORS AND TIGHTEN ELECTRICAL CONNECTORS AND TERMINALS ACCORDING TO MANUFACTURER'S PUBLISH TORQUE-TIGHTENING VALUES. IF MANUFACTURER'S VALUES ARE NOT INDICATED, USE THOSE SPECIFIED IN UL 486A-486B. 1.2.6. FIELD QUALITY CONTROL FIELD QUALITY CONTROL 1.2.1.1. AFTER INSTALLING CONDUCTORS AND AFTER INSTALLING CONDUCTORS AND CABLES AND BEFORE ELECTRICAL CIRCUITRY HAS BEEN ENERGIZED, TEST CONDUCTORS FEEDING ALL NEW EQUIPMENT AND SERVICES FOR COMPLIANCE WITH REQUIREMENTS. CABLES WILL BE CONSIDERED DEFECTIVE IF THEY DO NOT PASS TESTS AND INSPECTIONS. 1.3. WIRING DEVICES WIRING DEVICES 1.3.1. DEVICES COLOR: WIRING DEVICES CONNECTED TO DEVICES COLOR: WIRING DEVICES CONNECTED TO NORMAL POWER SYSTEMS SHALL BE WHITE UNLESS OTHERWISE INDICATED OR REQUIRED BY NFPA 70 OR DEVICE LISTING. 1.3.2. CONVENIENCE RECEPTACLES: NEMA WD-1, NEMA CONVENIENCE RECEPTACLES: NEMA WD-1, NEMA WD-6, CONFIGURATION 5-20R, AND UL 498. 1.3.3. DUPLEX GROUND-FAULT CIRCUIT-INTERRUPTER DUPLEX GROUND-FAULT CIRCUIT-INTERRUPTER (GFCI) CONVENIENCE RECEPTACLES: 125-V, 20-A, STRAIGHT BLADE, FEED-THROUGH TYPE, NEMA WD-1, NEMA WD-6, UL 498, AND UL 943, CLASS A, AND INCLUDE INDICATOR LIGHT THAT IS LIGHTED WHEN DEVICE IS TRIPPED. 1.3.4. TOGGLE SWITCHES: NEMA WD-1 AND UL 20, TOGGLE SWITCHES: NEMA WD-1 AND UL 20, SINGLE-POLE, 120/277V, 20A. 1.3.5. WALL-BOX DIMMERS WALL-BOX DIMMERS 1.3.5.1. MODULAR, FULL-WAVE, SOLID-STATE UNITS MODULAR, FULL-WAVE, SOLID-STATE UNITS WITH INTEGRAL, QUIET ON-OFF SWTICHES WITH AUDIBLE FREQUENCY AND EMI/RFI SUPPRESSION FILTERS. 1.3.5.2. CONTINUOUSLY ADJUSTABLE SLIDER CONTINUOUSLY ADJUSTABLE SLIDER CONTROL WITH SINGLE-POLE OR THREE-WAY SWITCHING, COMPLYING WITH UL 1472. 1.3.6. WALL PLATES WALL PLATES 1.3.6.1. SMOOTH, HIGH-IMPACT THERMOPLASTIC, SMOOTH, HIGH-IMPACT THERMOPLASTIC, WHITE, FASTENED WITH METAL SCREWS HAVING HEADS MATCHING PLATE COLOR. 1.3.6.2. FOR DAMP AREAS, THERMOPLASTIC AND FOR DAMP AREAS, THERMOPLASTIC AND LISTED AND LABELED FOR USE IN DAMP AREAS. 1.3.7. DO NOT USE OVERSIZED OR EXTRA-DEEP DO NOT USE OVERSIZED OR EXTRA-DEEP PLATES. REPAIR WALL FINISHES AND REMOUNT OUTLET BOXES WHEN STANDARD DEVICE PLATES DO NOT FLUSH OR COVER ROUGH WALL OPENING. 1.3.8. MOUNT DEVICES FLUSH, WITH LONG DIMENSION MOUNT DEVICES FLUSH, WITH LONG DIMENSION VERTICAL, AND GROUNDING TERMINAL OF RECEPTACLES ON TOP UNLESS OTHERWISE INDICATED. GROUP ADJACENT DEVICES UNDER SINGLE, MULTI-GANG WALL PLATES. 1.3.9. INSTALL UNSHARED NEUTRAL CONDUCTORS ON INSTALL UNSHARED NEUTRAL CONDUCTORS ON LINE AND LOAD SIDE OF DIMMERS. 1.4. RACEWAYS AND BOXES RACEWAYS AND BOXES 1.4.1. METAL CONDUITS, TUBING, AND FITTINGS SHALL METAL CONDUITS, TUBING, AND FITTINGS SHALL SHALL BE LISTED AND LABELED AS DEFINED IN NFPA 70, BY A QUALIFIED TESTING AGENCY, AND MARKED FOR INTENDED LOCATION AND APPLICATION. 1.4.2. FLEXIBLE METAL CONDUIT (FMC): COMPLY WITH FLEXIBLE METAL CONDUIT (FMC): COMPLY WITH UL 1, ALUMNIMUM, WITH FITTINGS SPECIFICALLY DESIGNED FOR USE WITH FMC. 1.4.3. ELECTRICAL METALLIC TUBING (EMT): COMPLY ELECTRICAL METALLIC TUBING (EMT): COMPLY WITH ANSI C80.3 AND UL 797. 1.4.4. INTERMEDIATE METAL CONDUIT (IMC): FOR USE INTERMEDIATE METAL CONDUIT (IMC): FOR USE IN INDOOR WET/DAMP LOCATIONS, COMPLY WITH ANSI C80.6 AND UL 1242, GALVANIZED. 1.4.5. OUTLET AND DEVICE BOXES: CAST-METAL, OUTLET AND DEVICE BOXES: CAST-METAL, FERROUS ALLOY, TYPE FD, WITH GASKETED COVER, NEMA FB-1 AND NEMA OS-1, AND MIN. 1-1/2" DEEP. FURNISH ALL PULL AND JUNCTION BOXES WITH SCREW-FASTENED COVERS. 1.4.6. INSTALL RACEWAYS AND CABLES CONCEALED IN INSTALL RACEWAYS AND CABLES CONCEALED IN FINISHED WALLS, CEILINGS, AND FLOORS UNLESS OTHERWISE INDICATED. . 1.4.7. INSTALL HANGERS AND SUPPORTS AS REQUIRED INSTALL HANGERS AND SUPPORTS AS REQUIRED FOR RACEWAY APPLICATION, AND SEPARATE DISSIMILAR METALS AND METAL PRODUCTS FROM CONTACT WITH WOOD OR CEMENTITIOUS MATERIALS BY PAINTING EACH METAL SURFACE IN AREA OF CONTACT WITH A BITUMINOUS COATING OR BY OTHER PERMANENT SEPARATION. 1.4.8. INSTALL PULL WIRES IN EMPTY RACEWAYS. INSTALL PULL WIRES IN EMPTY RACEWAYS. 1.5. LIGHTING LIGHTING 1.5.1. FURNISH ALL MATERIALS TO COMPLETE FURNISH ALL MATERIALS TO COMPLETE INSTALLATION OF LIGHTING. SET FIXTURES PLUMB, SQUARE, AND LEVEL WITH CEILINGS AND WALLS, IN ALIGNMENT WITH ADJACENT LIGHT FIXTURES, WITH ALL NEW LIGHTING CONTROLS. 1.5.2. SECURE IN ACCORDANCE WITH MANUFACTURER'S SECURE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND NFPA 70.

1 1

DEMO LEGEND (REMOVE)

WALL (DEMO)

1 DEMO DOOR

2 DEMO WAINSCOTINGLIGHT FIXTURE

3 DEMO CLOSET DOORS, TRACKS, ETC.

KEYED NOTES

3 3

REMOVE STEEL TUB,

WALL SUBWAY TILE,

AND SHOWER/BATH

FIXTURES. INCLUDE

REMOVAL OF GYP.

BOARD FOR NEW

SCHLUTER BOARD

REMOVE VANITY/SINK

LAYERED FLOOR /

CARPET / TILE

C E F G

B J I H

A

D

4 DEMO ALL CLOSET SHELVES,

RODS, GYP. BOARD, ETC.

KITCHEN/BATHROOM

TILE

SALVAGE AND

RELOCATE TOILET

REMOVE WOOD STOVE, PIPING,

AND BRICK WALL

REMOVE SLIDING

POCKET DOOR AND

FRAME

RELOCATE IN-FLOOR

HEATING LOCATION

RELOCATE

RECEPTACLE

RELOCATE DUPLEX

RECEPTACLE

EXISTING DUPLEX

RECEPTACLE

REMOVE WINDOW

OPTION: REMOVE ALL OPAQUE

WINDOWS LOCATED ABOVE

WALL AND REPLACE WITH

DUAL-PANE, ENERGY STAR

FIXED WINDOWS (NO SCREENS

REQUIRED)

5 DEMO KITCHEN, INCLUDING ALL

CABINETS, COUNTERTOPS, SINK,

GARBAGE DISPOSAL, DISHWASHER.

REMOVE SWITCHES, RECEPTACLES,

AND WIRING BACK TO PANEL

DEMO FURRED DOWN WALLS

AT EXISTING HANGING CABINET

LOCATIONS AND POCKET

SLIDING DOOR LOCATION (MAY RELOCATE

RECEPTACLE FOR NEW LOCATION)

EXISTING RECEPTACLE TO

REMAIN IN NEW DIVIDING

WALL

DRAWING TITLE

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

6/8 /20

:1

4 R

IC

HA

RD

RP

OL

AN

CO

C :\U

SE

RS

\R

IC

HA

RD

RP

OL

AN

CO

\D

ES

KT

OP

\R P\

PR

OJ

EC

TS

\Y

AQ

UI

H

OU

SE

R

EN

OV

AT

IO

N

AN

D

FL

OO

RI

NG

\1_

PR

E-

SO

LI

CI

TA

TI

ON

\D

RA

W

IN

GS

\E

XH

IB

IT

XX

_D

RA

W

IN

GS

.D W

G;

R3

SOUTHWESTERN REGION

SOUTH YAQUI HOUSE

REMODEL

APACHE-SITGREAVES

NATIONAL FORESTS

SPRINGERVILLE RANGER

DISTRICT

DEMO PLAN

06/08/2020

R.POLANCO

R.POLANCO

C.MILLER

A-01

0180064' 8'2'0

SCALE

1" = 4'

1'

SHEET NOTES

1. DEMO ALL LAYERS OF FLOORING (INC. ADHESIVE) TO CONCRETE (CARPET, CARPET, PAD,

AND 9X9 TILE FOR ALL ROOMS OTHER THAN ROOMS A AND J, WHICH HAVE ONE LAYER TILE).

2. DEMO ALL LIGHT FIXTURES (INCL. TWO (2) EXTERIOR AND ONE (1) SECURITY LIGHT).

3. DEMO ALL BASE BOARD WHERE FLOORING IS BEING REMOVED.

4. FOR ROOMS I AND H (BATHROOMS), REMOVE MEDICINE CABINETS, MIRRORS, TOILET

PAPER HOLDERS, AND ALL OTHER ACCESSORIES.

5 REMOVE ALL WINDOW CURTAINS, RODS, AND ACCESSORIES.

6. REMOVE ALL WALL AND CEILING HOOKS, NAILS, ETC. IN PREPARATION FOR PAINT.

7. REMOVE ALL 21

2" X 14" REGISTERS, AND 7"X12" REGISTERS IN BATHROOMS

8. REMOVE ALL LIGHT SWITCHES/PLATES AND

DUPLEX WALL PLATES.

9. DEMO ALL GYP. BOARD IN ROOM G AREAS TO NEW

BATHROOM EXTENTS.

N

AutoCAD SHX Text

PROJECT NAME

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

E

C E F G

B J I H

D

LEGEND

NEW FLOOR TO

CEILING WALL

NEW DIVIDING

WALL

A DRAWING TITLE

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

6/8 /20

:1

4 R

IC

HA

RD

RP

OL

AN

CO

C :\U

SE

RS

\R

IC

HA

RD

RP

OL

AN

CO

\D

ES

KT

OP

\R P\

PR

OJ

EC

TS

\Y

AQ

UI

H

OU

SE

R

EN

OV

AT

IO

N

AN

D

FL

OO

RI

NG

\1_

PR

E-

SO

LI

CI

TA

TI

ON

\D

RA

W

IN

GS

\E

XH

IB

IT

XX

_D

RA

W

IN

GS

.D W

G;

R3

SOUTHWESTERN REGION

SOUTH YAQUI HOUSE

REMODEL

APACHE-SITGREAVES

NATIONAL FORESTS

SPRINGERVILLE RANGER

DISTRICT

REMODEL LAYOUT

NEW DIMENSIONS

06/08/2020

R.POLANCO

R.POLANCO

C.MILLER

A-02

018007

N

4' 8'2'0

SCALE

1" = 4'

1'

5'-10"

1'-

12'-5"

9'-10"

2'-3"

6'-3"

3'-5"

5'-10"

4'-4"

10'-1"

1'-9"

5'-5"

1'-9"

4'-0"

7'-9"

2'-0"

2'-5"

2'-0"

2'-0"

4'-2"

4'-0"

4'-0"

3'-0"

5'-9"

8'-4"

1'-4"

2'-8"

2'-5"

8'-71 2"

3'-2"

AutoCAD SHX Text

PROJECT NAME

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

REQ'D CLEAR

SPACE

REQ'D CLEAR

SPACE

D1

D3

1 NOT USED

3 INSTALL BIFOLD LOUVERED CLOSET DOORS

KEYED NOTES

4 INSTALL BIFOLD 6-PANEL CLOSET DOORS

5 ACCENT WALL, BEHR MOCHA LIGHT, BWC-24

SMALLER DOOR THAN SCHEDULE;

FIELD MEASURE

NEW SINK,

DRAWERS,

AND COUNTERTOP

LEGEND

NEW FLOOR TO

CEILING WALL

NEW DIVIDING

WALL

NEW TOILET

LOCATION

GRAB BARS,

2" DIA. (TYP.)

C E F G

B J I

H

D

CONTROL WALL; INSTALL NEW

SHOWER HEAD, LEVER, AND

BATH FAUCET WITH SAME

ELEVATIONS AS ROOM H

4 4 4

RELOCATE TO

THIS LOCATION

RELOCATE RECEPTACLE

TO THIS LOCATION

RELOCATE DUPLEX

RECEPTACLE TO THIS

LOCATION

EXISTING DUPLEX

RECEPTACLE

INSTALL GOVERNMENT-FURNISHED PELLET STOVE.

RUN ELECTRICAL FROM NEAREST POWER SOURCE

TO STOVE, AND INSTALL NEW SWITCH. INSTALL NEW

STOVE PIPING AS REQUIRED BY CODE TO THE

EXISTING CEILING LOCATION

5 5 5 5

6 BATH/SHOWER COMBO UNIT

7 NEW 12"X24" SLIDING WINDOW WITH FROSTED FILM,

DUAL-PANE, INSULATING AIR LAYER, WITH ADDITIONAL STUD

SUPPORT AS NEEDED

INSTALL HEARTH PAD PER

MANUFACTURER'S

INSTRUCTIONS AND THIN-SET

MORTAR ON CONCRETE

OPTIONAL FLOOR TO WINDOW

ROCKWORK

USE EXISTING FRESH AIR INTAKE

LOCATION AND PIPE TO NEW

STOVE PER MANUFACTURER'S

INSTRUCTIONS

D3D3

D2

INSTALL SHELVES, ROD, ETC.

PER SETUP IN ROOMS E AND F

D4

D5

A

CABINETS AND COUNTERTOP

KITCHEN ISLAND

INSTALL 4"X4" COLUMN TO

SUPPORT MAIN BEAM (REFER TO

AS-BUILTS), DRYWALL, TEXTURED,

AND PAINTED (TYP.)

COUNTERTOP; ON TOP OF DIVIDING

WALL AND EXTEND FOR SEATING

AS SHOWN, 42" AFF. CUT AS

NEEDED TO TO WRAP AROUND

NEW COLUMNS.

DIVIDING WALL,

40.5" AFF

DRAWING TITLE

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

6/8 /20

:1

4 R

IC

HA

RD

RP

OL

AN

CO

C :\U

SE

RS

\R

IC

HA

RD

RP

OL

AN

CO

\D

ES

KT

OP

\R P\

PR

OJ

EC

TS

\Y

AQ

UI

H

OU

SE

R

EN

OV

AT

IO

N

AN

D

FL

OO

RI

NG

\1_

PR

E-

SO

LI

CI

TA

TI

ON

\D

RA

W

IN

GS

\E

XH

IB

IT

XX

_D

RA

W

IN

GS

.D W

G;

R3

SOUTHWESTERN REGION

SOUTH YAQUI HOUSE

REMODEL

APACHE-SITGREAVES

NATIONAL FORESTS

SPRINGERVILLE RANGER

DISTRICT

REMODEL FLOOR

PLAN

06/08/2020

R.POLANCO

R.POLANCO

C.MILLER

A-03

018008

N

4' 8'2'0

SCALE

1" = 4'

1'

SHEET NOTES

1. INSTALL NEW 2" WOOD FAUX BLINDS FOR ALL WINDOWS, EXCLUDING BATHROOMS AND THE

OPAQUE DECORATIVE WINDOWS IN ROOMS B AND C. INCLUDE HEAD RAIL AND END CAP.

2. IN ROOM H, INSTALL SEWER TO NEW TOILET, BATHTUB, AND SINK LOCATIONS BY

TRENCHING AND INSTALL OUTSIDE OF THE BUILDING TO SEWER LOCATIONS JUST NORTH OF

ROOMS I AND H (CLEANOUTS ARE VISIBLE). INSTALL CLEANOUTS PER CODE.

3. CAP/ABANDON EXISTING TOILET SEWER/DRAIN IN ROOM H.

4. IN ROOM H, INSTALL NEW PEX PLUMBING FROM EXISTING LOCATIONS TO NEW PLUMBING

FIXTURES (RED FOR HOT LINE AND BLUE FOR COLD LINES).

5. REPLACE ALL 2-1/2"X14" HVAC FLOOR REGISTERS WITH NEW, BLACK REGISTERS. REPLACE

7"X12" BATHROOM REGISTERS WITH NEW, ULTRA WHITE

REGISTERS.

6. PREP, PRIME, AND PAINT ALL CEILINGS AND WALLS.

7. PREP, PRIME, AND PAINT HOUSE EXTERIOR.

AutoCAD SHX Text

PROJECT NAME

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text A-06

AutoCAD SHX Text

AutoCAD SHX Text A-06

AutoCAD SHX Text

AutoCAD SHX Text A-06

GRAB

BARS (TYP.)

TOWEL

BAR

TOILET PAPER

HOLDER

RECESSED MIRRORED

MEDICINE CABINET

RELOCATED AFCI/GFCI PROTECTED

DUPLEX RECEPTACLE

EAST WALL NORTH WALL

WEST WALL SOUTH WALL

VANITY LIGHT

FIXTURE

MIRROR

12" x 24"

SLIDING WINDOW

DRAWERS AS

SHOWN

RELOCATE REGISTER/DUCT TO

THIS LOCATION

EXISTING REGISTER

LOCATION

ACCESSIBLE SPACE; SEE

DETAIL 1B, SHEET A-10

DIVIDING

WALL

LAMINATE COUNTERTOP

WITH BACKSPLASH

CURTAIN ROD

DRAWING TITLE

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

6/8 /20

:1

4 R

IC

HA

RD

RP

OL

AN

CO

C :\U

SE

RS

\R

IC

HA

RD

RP

OL

AN

CO

\D

ES

KT

OP

\R P\

PR

OJ

EC

TS

\Y

AQ

UI

H

OU

SE

R

EN

OV

AT

IO

N

AN

D

FL

OO

RI

NG

\1_

PR

E-

SO

LI

CI

TA

TI

ON

\D

RA

W

IN

GS

\E

XH

IB

IT

XX

_D

RA

W

IN

GS

.D W

G;

R3

SOUTHWESTERN REGION

SOUTH YAQUI HOUSE

REMODEL

APACHE-SITGREAVES

NATIONAL FORESTS

SPRINGERVILLE RANGER

DISTRICT

ROOM H ELEVATION

VIEWS

06/08/2020

R.POLANCO

R.POLANCO

C.MILLER

A-04

0180092' 4'1'0

SCALE

1" = 2'

6"

ROOM H

3'-0" 6'-4"

4"

2'-4"

7"

2'-0"

3'-111 2"

2'-2" 2'-11" 2'-3"

4"

4"

4'-1" 4'-9"

1'-9" 3'-0"

2'-7"

4" 3'-7"

3'-0"

6"

1'-0" 1'-0"

7"

1'-9"

7'-0"3'-0"1'-10"

2'-10"

3'-7" 2'-0"

AutoCAD SHX Text

PROJECT NAME

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

TOILET TO

REMAIN

VANITY LIGHT

FIXTURE

MIRROR

DRAWERS AND

CABINETS AS

SHOWN

TOILET PAPER

HOLDER

TOWEL BAR

BATH/SHOWER

COMBO UNIT

(BACK WALL)

EXISTING WINDOW

(TO REMAIN)

REPLACE

REGISTER

NORTH WALL EAST WALL

CURTAIN ROD

DRAWING TITLE

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

6/8 /20

:1

4 R

IC

HA

RD

RP

OL

AN

CO

C :\U

SE

RS

\R

IC

HA

RD

RP

OL

AN

CO

\D

ES

KT

OP

\R P\

PR

OJ

EC

TS

\Y

AQ

UI

H

OU

SE

R

EN

OV

AT

IO

N

AN

D

FL

OO

RI

NG

\1_

PR

E-

SO

LI

CI

TA

TI

ON

\D

RA

W

IN

GS

\E

XH

IB

IT

XX

_D

RA

W

IN

GS

.D W

G;

R3

SOUTHWESTERN REGION

SOUTH YAQUI HOUSE

REMODEL

APACHE-SITGREAVES

NATIONAL FORESTS

SPRINGERVILLE RANGER

DISTRICT

ROOM I ELEVATION

VIEWS

06/08/2020

R.POLANCO

R.POLANCO

C.MILLER

A-05

0180102' 4'1'0

SCALE

1" = 2'

6"

SHEET NOTES

1. FOR ALL WET AREAS IN ROOMS H AND I (BEHIND NEW BATH/SHOWER

COMBO UNIT), REMOVE ALL EXISTING GYP. BOARD AND REPLACE WITH

SHLUTER BOARD.

ROOM I

2'-7"

4'-0"

4"

4'-1"

3'-0" 1'-0"

6'-4"

2'-0" 3'-10"

2'-10"

6"

AutoCAD SHX Text

PROJECT NAME

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

RE-WIRE SWITCH

TO GARBAGE

DISPOSAL (CURRENTLY

NOT FUNCTIONING)

RELOCATE

KITCHEN LIGHT

SWITCH TO

NEW LOCATION

REMOVE CEILING VENT

AND SWITCHING, WIRING,

ETC.

NEW GARBAGE

DISPOSAL

NEW SINKNEW OVER THE

RANGE MICROWAVE

AND ASSOCIATED

ELECTRICAL INSTALL DISH WASHER

INSTALL 20A DEDICATED

CIRCUIT FOR REFRIGERATOR;

RELOCATE EXISTING WIRING/

RECEPTACLE FROM OLD

REFRIGERATOR LOCATION IS

ACCEPTABLE

EXISTING

WINDOW

NEW WALL CABINETS

AS SHOWN

NEW

COUNTERTOP

WITH BACKSPLASH

KITCHEN ISLAND WITH

CASEWORK AND COUNTERTOP

AS SHOWN

NEW 4X4 COLUMN

EXISTING 2X12 BEAMS

EXISTING

TELEPHONE

JACK

DRAWING TITLE

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

6/8 /20

:1

4 R

IC

HA

RD

RP

OL

AN

CO

C :\U

SE

RS

\R

IC

HA

RD

RP

OL

AN

CO

\D

ES

KT

OP

\R P\

PR

OJ

EC

TS

\Y

AQ

UI

H

OU

SE

R

EN

OV

AT

IO

N

AN

D

FL

OO

RI

NG

\1_

PR

E-

SO

LI

CI

TA

TI

ON

\D

RA

W

IN

GS

\E

XH

IB

IT

XX

_D

RA

W

IN

GS

.D W

G;

R3

SOUTHWESTERN REGION

SOUTH YAQUI HOUSE

REMODEL

APACHE-SITGREAVES

NATIONAL FORESTS

SPRINGERVILLE RANGER

DISTRICT

ROOM A (KITCHEN)

ELEVATION VIEWS

06/08/2020

R.POLANCO

R.POLANCO

C.MILLER

A-06

0180112' 4'1'0

SCALE

1" = 2'

6"

SHEET NOTES

1. PLUMB NEW WATER LINE TO REFRIGERATOR LOCATION. CONNECT IF

REFRIGERATOR AND INSTALLATION OPTION IS AWARDED.

ROOM A

SECTION 1 - WEST WALL

SECTION 3 - EAST WALL

SECTION 2 - NORTH WALL

4'-2"

3'-6"3'-0"

3'-0"

3"

5'-0"

2'-6"

2'-2"

AutoCAD SHX Text

PROJECT NAME

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

FLOORING (NEW)

1 NOT USED

KEYED NOTES

VINYL PLANK

FLOORING, BASE

BOARD, AND

MOULDING

DRAWING TITLE

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

6/8 /20

:1

4 R

IC

HA

RD

RP

OL

AN

CO

C :\U

SE

RS

\R

IC

HA

RD

RP

OL

AN

CO

\D

ES

KT

OP

\R P\

PR

OJ

EC

TS

\Y

AQ

UI

H

OU

SE

R

EN

OV

AT

IO

N

AN

D

FL

OO

RI

NG

\1_

PR

E-

SO

LI

CI

TA

TI

ON

\D

RA

W

IN

GS

\E

XH

IB

IT

XX

_D

RA

W

IN

GS

.D W

G;

R3

SOUTHWESTERN REGION

SOUTH YAQUI HOUSE

REMODEL

APACHE-SITGREAVES

NATIONAL FORESTS

SPRINGERVILLE RANGER

DISTRICT

NEW FLOORING

06/08/2020

R.POLANCO

R.POLANCO

C.MILLER

A-07

018012

N

4' 8'2'0

SCALE

1" = 4'

1'

SHEET NOTES

1. LIMIT BASEBOARD REMOVAL DAMAGE TO THE MOST PRACTICAL EXTENT. SKIM AND TEXTURE AS

NEEDED TO RECEIVE NEW BASE BOARD AND MOULDING.

2. BASEBOARD AND MOULDING NOT REQUIRED FOR FLOORING ADJOINING MILLWORK. INSTALL

TOE KICKS FOR ALL NEW CABINETRY/DRAWERS.

3. PLANK PATTERN SHALL BE OFFSET, EAST-WEST (OFFSET BY HALF THE WIDTH OF THE PLANK).

4. FOR BASEBOARD/MOULDING APPLICATIONS IN BATHROOMS, PLACE WATER-PROOF CAULK

BEHIND TO PREVENT WATER FROM PENETRATING.

5. FOR INSIDE AND OUTSIDE CORNER MOULDING APPLICATION, USE MILTER JOINTS (CUT AT 45

DEGREE ANGLE).

AutoCAD SHX Text

PROJECT NAME

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

6/8 /20

:1

4 R

IC

HA

RD

RP

OL

AN

CO

C :\U

SE

RS

\R

IC

HA

RD

RP

OL

AN

CO

\D

ES

KT

OP

\R P\

PR

OJ

EC

TS

\Y

AQ

UI

H

OU

SE

R

EN

OV

AT

IO

N

AN

D

FL

OO

RI

NG

\1_

PR

E-

SO

LI

CI

TA

TI

ON

\D

RA

W

IN

GS

\E

XH

IB

IT

XX

_D

RA

W

IN

GS

.D W

G;

R3

SOUTHWESTERN REGION

SOUTH YAQUI HOUSE

REMODEL

APACHE-SITGREAVES

NATIONAL FORESTS

SPRINGERVILLE RANGER

DISTRICT

FINISH AND LIGHTING

SCHEDULE

06/08/2020

R.POLANCO

R.POLANCO

C.MILLER

A-08

018013

AutoCAD SHX Text

PROJECT NAME

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

6/8 /20

:1

4 R

IC

HA

RD

RP

OL

AN

CO

C :\U

SE

RS

\R

IC

HA

RD

RP

OL

AN

CO

\D

ES

KT

OP

\R P\

PR

OJ

EC

TS

\Y

AQ

UI

H

OU

SE

R

EN

OV

AT

IO

N

AN

D

FL

OO

RI

NG

\1_

PR

E-

SO

LI

CI

TA

TI

ON

\D

RA

W

IN

GS

\E

XH

IB

IT

XX

_D

RA

W

IN

GS

.D W

G;

R3

SOUTHWESTERN REGION

SOUTH YAQUI HOUSE

REMODEL

APACHE-SITGREAVES

NATIONAL FORESTS

SPRINGERVILLE RANGER

DISTRICT

HARDWARE, DECOR,

AND EQUIPMENT

SCHEDULE

06/08/2020

R.POLANCO

R.POLANCO

C.MILLER

A-09

018014

AutoCAD SHX Text

PROJECT NAME

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

6/8 /20

:1

4 R

IC

HA

RD

RP

OL

AN

CO

C :\U

SE

RS

\R

IC

HA

RD

RP

OL

AN

CO

\D

ES

KT

OP

\R P\

PR

OJ

EC

TS

\Y

AQ

UI

H

OU

SE

R

EN

OV

AT

IO

N

AN

D

FL

OO

RI

NG

\1_

PR

E-

SO

LI

CI

TA

TI

ON

\D

RA

W

IN

GS

\E

XH

IB

IT

XX

_D

RA

W

IN

GS

.D W

G;

R3

SOUTHWESTERN REGION

SOUTH YAQUI HOUSE

REMODEL

APACHE-SITGREAVES

NATIONAL FORESTS

SPRINGERVILLE RANGER

DISTRICT

HARDWARE, DECOR,

AND EQUIPMENT

SCHEDULE (CONT'D)

06/08/2020

R.POLANCO

R.POLANCO

C.MILLER

A-10

018015

AutoCAD SHX Text

PROJECT NAME

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

6/8 /20

:1

4 R

IC

HA

RD

RP

OL

AN

CO

C :\U

SE

RS

\R

IC

HA

RD

RP

OL

AN

CO

\D

ES

KT

OP

\R P\

PR

OJ

EC

TS

\Y

AQ

UI

H

OU

SE

R

EN

OV

AT

IO

N

AN

D

FL

OO

RI

NG

\1_

PR

E-

SO

LI

CI

TA

TI

ON

\D

RA

W

IN

GS

\E

XH

IB

IT

XX

_D

RA

W

IN

GS

.D W

G;

R3

SOUTHWESTERN REGION

SOUTH YAQUI HOUSE

REMODEL

APACHE-SITGREAVES

NATIONAL FORESTS

SPRINGERVILLE RANGER

DISTRICT

DOOR SCHEDULE

06/08/2020

R.POLANCO

R.POLANCO

C.MILLER

A-11

018016

AutoCAD SHX Text

PROJECT NAME

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

6/8 /20

:1

4 R

IC

HA

RD

RP

OL

AN

CO

C :\U

SE

RS

\R

IC

HA

RD

RP

OL

AN

CO

\D

ES

KT

OP

\R P\

PR

OJ

EC

TS

\Y

AQ

UI

H

OU

SE

R

EN

OV

AT

IO

N

AN

D

FL

OO

RI

NG

\1_

PR

E-

SO

LI

CI

TA

TI

ON

\D

RA

W

IN

GS

\E

XH

IB

IT

XX

_D

RA

W

IN

GS

.D W

G;

R3

SOUTHWESTERN REGION

SOUTH YAQUI HOUSE

REMODEL

APACHE-SITGREAVES

NATIONAL FORESTS

SPRINGERVILLE RANGER

DISTRICT

CONSTRUCTION

DETAILS

06/08/2020

R.POLANCO

R.POLANCO

C.MILLER

A-12

018017

HOLLOW CORE COMPOSITE INTERIOR DOOR

NO SCALE

ELEVATION VIEWDETAIL 1A

6'-8"

SEE DOOR SCHEDULE

FOR HARDWARE

42"

4" X 4" STANDARD

HINGES (TYP.); SATIN-

CHROME FINISH; SIZED

AND GAUGED FOR

DOOR WEIGHT

42"

FOR ALL NEW DOORS, INSTALL ALL

REQUIRED TO MAKE DOOR FULLY

FUNCTIONAL, INCLUDING NEW DOOR

STRIKES, HINGES, ETC. ALL

MISCELLANEOUS HARDWARE SHALL BE

SATIN-CHROME FINISH.

PAINT DOORS AND WOOD BASE (WHITE)

TO MATCH BASEBOARD/MOULDING.

PROVIDE NEW WOOD TRIM AT NEW

LOCATIONS.

ROOMS E / F / G: KEYED INDIVIDUALLY

ROOM H: INSTALL PRE-HUNG ASSEMBLY.

DOOR; REFER

TO SCHEDULE WOOD FRAME

FRAME ANCHOR;

PROVIDE THREE (3)

PER JAMB MIN.

PAIR WOOD STUDS;

SECURED TOGETHER

AT 16" O.C. VERTICAL

(TYP.)

SEALANT BOTH SIDES

AT FRAME

1/2" BOARD

W/ METAL

EDGE

2"

2"

2"

2"

9/16" X 3-1/4" WOOD BASE

(TYP. BOTH SIDES)

DETAIL 3A CROSS SECTION

INTERIOR DOOR JAMB

NO SCALE

DETAIL 4A CROSS SECTION

INTERIOR DOOR HEADER

NO SCALE

1/2" BOARD (SEE

FINISH SCHEDULE

FOR TYPE)

2" 2" 2"

2"

WOOD FRAME

TWO (2) 2X8 STUD RUNNERS

SECURED TO DOUBLE STUD

AT EACH END. CONTINUOUS

SEALANT BOTH SIDES

AT FRAME (TYP.)

CEILING (HEIGHT

VARIES)

9/16" X 3-1/4" WOOD

BASE (TYP. BOTH

SIDES)

DOOR; REFER

TO SCHEDULE

DETAIL 2A CROSS SECTION

ACCESSIBLE SINK/CABINET

SCALE: 1" = 1'

9"9"

2'-3"

4"

4"

9" 3"

1'-9"

FLAT PANELS SAME

FINISH/COLOR AS CABINETRY

(NO PRAIRIE STYLE REQUIRED)

DETAIL 5A PLAN VIEW

NEW WALL TYPICAL

NO SCALE

1/2" BOARD (TYP.); SEE

WALL SHEET NOTES FOR

SPECIFIC MATERIAL

REQUIREMENTS

SOUND ATTENUATING

INSULATION

2X4 WOOD STUDS

AT 16" O.C.

AutoCAD SHX Text

PROJECT NAME

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

LIGHTING LEGEND

VANITY LIGHT FIXTURE

HUNTER CHANNING CEILING/LIGHT

HUNTER DONEGAN CEILING/LIGHT

HALO LED TILTABLE

VENT/LIGHT COMBOVL

VL

VL

EXTERIOR LIGHT (INSTALL…

This is the start of the file's text. The full file is on GovTribe.