Exhibit3_Drawings_20200608.pdf
PDF 3 MB Posted
- Attached to
- Remodel the South Yaqui House.
- Solicitation number
- 12837120Q0175
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT LOCATION
VICINITY MAP
SHEET OF
United States Department of Agriculture
Forest Service
INDEX OF SHEETS
SHEET SHEET TITLE DATE
G-01 COVER SHEET 6/8/2020
G-02 GENERAL NOTES 6/8/2020
G-03 GENERAL SPECIFICATIONS 6/8/2020
G-04
ELECTRICAL, HARDWARE, AND PAINT
SPECIFICATIONS
6/8/2020
G-05 ELECTRICAL SPECIFICATIONS 6/8/2020
A-01 DEMO PLAN 6/8/2020
A-02 REMODEL LAYOUT NEW DIMENSIONS 6/8/2020
A-03 REMODEL FLOOR PLAN 6/8/2020
A-04 ROOM H ELEVATION VIEWS 6/8/2020
A-05 ROOM I ELEVATION VIEWS 6/8/2020
A-06 ROOM A ELEVATION VIEWS 6/8/2020
A-07 NEW FLOORING 6/8/2020
A-08 FINISH AND LIGHTING SCHEDULE 6/8/2020
A-09
HARDWARE, DECOR, AND EQUIPMENT
SCHEDULE
6/8/2020
A-10
HARDWARE, DECOR, AND EQUIPMENT
SCHEDULE (CONTINUED)
6/8/2020
A-11 DOOR SCHEDULE 6/8/2020
A-12 CONSTRUCTION DETAILS 6/8/2020
E-01 NEW LIGHTING PLAN 6/8/2020
ADDRESS:
Southeast Corner of Pima Street and Yaqui Street, Springerville, AZ 85938
LAT: 34.130126° / LONG: -109.279609°
DATE
RECOMMENDED BY:
APPROVED:
FOREST ENGINEER
FOREST SUPERVISOR
DISTRICT RANGER DATE
DIRECTOR OF ENGINEERING
DATE
RO FACILITIES PROGRAM MANAGER
DATE
DATE
SOUTH YAQUI
HOUSE REMODEL
STATE OF ARIZONA
APACHE COUNTY
APACHE-SITGREAVES NATIONAL FORESTS
R3 SOUTHWESTERN REGION
SPRINGERVILLE, AZ
S. YAQUI HOUSE
PROJECT LOCATION
updated 06/08/2020
DRAWING TITLE
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
6/8 /20
:1
4 R
IC
HA
RD
RP
OL
AN
CO
C :\U
SE
RS
\R
IC
HA
RD
RP
OL
AN
CO
\D
ES
KT
OP
\R P\
PR
OJ
EC
TS
\Y
AQ
UI
H
OU
SE
R
EN
OV
AT
IO
N
AN
D
FL
OO
RI
NG
\1_
PR
E-
SO
LI
CI
TA
TI
ON
\D
RA
W
IN
GS
\E
XH
IB
IT
XX
_D
RA
W
IN
GS
.D W
G;
R3
SOUTHWESTERN REGION
SOUTH YAQUI HOUSE
REMODEL
APACHE-SITGREAVES
NATIONAL FORESTS
SPRINGERVILLE RANGER
DISTRICT
GENERAL NOTES
06/08/2020
R.POLANCO
R.POLANCO
C.MILLER
G-02
018002
INDEX OF DRAWINGS
ARCHITECTURAL LEGEND
GENERAL NOTES
W1 D1
WORK SUMMARY
DEMO AND CONSTRUCTION SEQUENCE
A
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text A-01
AutoCAD SHX Text
DISCIPLINE
AutoCAD SHX Text A - ARCHITECTURE C - CIVIL E - ELECTRICAL G - GENERAL L - LANDSCAPE M - MECHANICAL
AutoCAD SHX Text
SHEET NUMBER WITHIN SERIES
AutoCAD SHX Text
ANNOTATION CALLOUTS/SYMBOLS
AutoCAD SHX Text A-01
AutoCAD SHX Text A-01
AutoCAD SHX Text A-01
AutoCAD SHX Text
INTERIOR ELEVATION
AutoCAD SHX Text
SHEET NUMBER WHERE SECTION/DETAIL IS DRAWN
AutoCAD SHX Text
EXTERIOR ELEVATION
AutoCAD SHX Text
SHEET NUMBER WHERE SECTION/DETAIL IS DRAWN
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
SHEET NUMBER WHERE SECTION/DETAIL IS DRAWN
AutoCAD SHX Text
AutoCAD SHX Text
KEYED NOTE
AutoCAD SHX Text
WINDOW NUMBER
AutoCAD SHX Text
DOOR NUMBER
AutoCAD SHX Text
WALL, FLOOR, AND CEILING SYMBOLS
AutoCAD SHX Text
1. THE "CONTRACTOR" AS REFERENCED HEREIN REFERS TO THE THE "CONTRACTOR" AS REFERENCED HEREIN REFERS TO THE COMPANY OR PERSON PERFORMING THE INSTRUCTED WORK. 2. THE "COR" AS REFERENCED HEREIN REFERS TO THE THE "COR" AS REFERENCED HEREIN REFERS TO THE CONTRACTING OFFICER'S REPRESENTATIVE. 3. CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS AS CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS AS REQUIRED BY LOCAL JURISDICTIONS, SPECIFICALLY TOWN BUILDING PERMITS AND ADEQ REQUIRED NESHAP REPORTING REQUIREMENTS AS A RESULT OF DEMOLITION ACTIVITIES. 4. CONSTRUCTION SHALL BE PER THE LATEST VERSION OF THE CONSTRUCTION SHALL BE PER THE LATEST VERSION OF THE APPLICABLE ENERGY, ELECTRICAL, PLUMBING, AND BUILDING CODES, OR THE CONSTRUCTION PLANS, WHICHEVER IS MORE STRINGENT. 5. FURNISH AND INSTALL ALL REQUIRED TO COMPLETE THE FURNISH AND INSTALL ALL REQUIRED TO COMPLETE THE PROJECT AS SHOWN HEREIN. IF THERE IS AN OMISSION ON THE PLANS, SUCH OMISSION SHALL NOT BE CONSTRUED TO MEAN THAT THE CONTRACTOR IS NOT REQUIRED TO FURNISH OR PROVIDE ALL THAT IS NECESSARY FOR COMPLETE AND OPERABLE FEATURES OF WORK. 6. ANY CHANGES TO THE DESIGN AS SHOWN MUST BE REVIEWED ANY CHANGES TO THE DESIGN AS SHOWN MUST BE REVIEWED AND APPROVED BY THE CONTRACTING OFFICER BEFORE CHANGES ARE MADE. THIS INCLUDES CHANGES REQUEST BY THE CONTRACTOR AND SUBCONTRACTORS. 7. THE CONTRACTOR SHALL CONTACT THE APPROPRIATE BLUE THE CONTRACTOR SHALL CONTACT THE APPROPRIATE BLUE STAKE TO MARK AND IDENTIFY UNDERGROUND UTILITIES PRIOR TO EXCAVATION.. 8. THE LOCATIONS AND MEASUREMENTS HEREIN ARE APPROXIMATE. THE LOCATIONS AND MEASUREMENTS HEREIN ARE APPROXIMATE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ALL MEASUREMENTS PRIOR TO ORDERING MATERIALS. 9. CONTRACTORS WORKING WITHIN THE PROJECT BOUNDARIES ARE CONTRACTORS WORKING WITHIN THE PROJECT BOUNDARIES ARE RESPONSIBLE FOR COMPLIANCE WITH ALL JURISDICTIONAL SAFETY LAWS AND REGULATIONS. 10. WHEN A PRODUCT IS SPECIFIED, AN APPROVED EQUAL MAY BE WHEN A PRODUCT IS SPECIFIED, AN APPROVED EQUAL MAY BE SUBSTITUTED SO LONG AS IT MEETS ALL TECHNICAL AND FINISH CRITERIA OF THE SPECIFIED PRODUCT. 11. THERE IS MINIMAL FURNITURE IN THE HOUSE (REFRIGERATORS, THERE IS MINIMAL FURNITURE IN THE HOUSE (REFRIGERATORS, BED FRAMES, ETC.). CONTRACTOR IS RESPONSIBLE FOR MOVING AROUND EXISTING FURNISHINGS TO ACCOMPLISH THE WORK. 12. FOR APPLIANCE INSTALLATION, ALL REQUIRED ELECTRICAL AND FOR APPLIANCE INSTALLATION, ALL REQUIRED ELECTRICAL AND PLUMBING CONNECTIONS, WIRING, PIPING, ETC. ARE INCIDENT TO THE WORK AND SHALL BE INCLUDED IN THE COST TO DO THE WORK.
AutoCAD SHX Text
1. WHEN THE TERMS "REMOVE", "DISPOSE", "DEMOLISH", OR WHEN THE TERMS "REMOVE", "DISPOSE", "DEMOLISH", OR "DEMO" ARE USED, DISPOSE LEGAL OFFSITE IN ACCORDANCE WITH APPLICABLE LOCAL, COUNTY, STATE, AND FEDERAL JURISDICTIONS. ANY SALVAGE VALUE AS A RESULT OF THE WORK SHALL BE INCLUDED IN THE INITIAL BIDDING DOCUMENT. 2. WHEN A FEATURE OF WORK INCLUDES DEMOLITION (SUCH AS WHEN A FEATURE OF WORK INCLUDES DEMOLITION (SUCH AS DOORS, FRAMES, LIGHTS, VENTS, RECESSED FIXTURES, ETC.), PATCH, AND REPAIR DRYWALL AFTER DEMOLITION ACTIVITIES ARE COMPLETE, TO INCLUDE ANY REQUIRED WOOD STUD FRAMING SECTIONS FOR THE VOIDS. 3. DEMO IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL EPA DEMO IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL EPA REGULATIONS WHEN ASBESTOS-CONTAINING MATERIALS AND LEAD-BASED PAINT ARE PRESENT. REFER TO CERTIFIED SAMPLING AND TESTING REPORT. 4. BUILDING WILL BE VACANT DURING CONSTRUCTION ACTIVITIES. BUILDING WILL BE VACANT DURING CONSTRUCTION ACTIVITIES. 5. PROVIDE FINAL CLEANING OF HOUSE PRIOR TO CONTRACTING PROVIDE FINAL CLEANING OF HOUSE PRIOR TO CONTRACTING OFFICER ACCEPTANCE.
AutoCAD SHX Text THE GOVERNMENT INTENDS TO AWARD A REMODEL PROJECT ON THE SPRINGERVILLE RANGER DISTRICT, SOUTH YAQUI HOUSE. THE PROJECT INCLUDES REMOVING ALL FLOORING (TILE CONSIST OF ASBESTOS), BASEBOARD, BATHROOM FIXTURES AND ACCESSORIES, AND DOOR/WALL DEMOLITION. REMODEL WORK INCLUDES NEW VINYL FLOORING, ADDING AN ACCESSIBLE BATHROOM, REPLACE DOORS, NEW WALLS, BATH/SHOWER UNITS, PELLET STOVE INSTALLATION, FULL KITCHEN REMODEL, AND LIGHTING. OPTION ITEMS INCLUDE REPLACING WINDOWS AND APPLIANCE REPLACEMENT.
AutoCAD SHX Text
ROOM NUMBER
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
6/8 /20
:1
4 R
IC
HA
RD
RP
OL
AN
CO
C :\U
SE
RS
\R
IC
HA
RD
RP
OL
AN
CO
\D
ES
KT
OP
\R P\
PR
OJ
EC
TS
\Y
AQ
UI
H
OU
SE
R
EN
OV
AT
IO
N
AN
D
FL
OO
RI
NG
\1_
PR
E-
SO
LI
CI
TA
TI
ON
\D
RA
W
IN
GS
\E
XH
IB
IT
XX
_D
RA
W
IN
GS
.D W
G;
R3
SOUTHWESTERN REGION
SOUTH YAQUI HOUSE
REMODEL
APACHE-SITGREAVES
NATIONAL FORESTS
SPRINGERVILLE RANGER
DISTRICT
GENERAL
SPECIFICATIONS
06/08/2020
R.POLANCO
R.POLANCO
C.MILLER
G-03
018003
SPECIFICATIONS
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text E
1. PLUMBING: FOR ALL NEW PLUMBING, USE THE LATEST PLUMBING: FOR ALL NEW PLUMBING, USE THE LATEST UNIVERSAL PLUMBING CODE (UPC). AT A MINIMUM: 1.1. INSTALL P-TRAPS FOR ALL NEW PLUMBING FIXTURE INSTALL P-TRAPS FOR ALL NEW PLUMBING FIXTURE LOCATIONS. CONTRACTOR IS RESPONSIBILE FOR DETERMINING SIZE AND SPACE NEEDED AND INSTALLING AS REQUIRED. 1.2. INSTALL ADEQUATE VENTING FOR ALL NEW PLUMBING INSTALL ADEQUATE VENTING FOR ALL NEW PLUMBING FIXTURES, INCLUDING PENETRATION(S) AS REQUIRED. SUBMIT SHOP DRAWINGS FOR APPROVAL. 1.3. INSTALL 4" PVC SEWER DRAIN FOR NEW LOCATIONS INSTALL 4" PVC SEWER DRAIN FOR NEW LOCATIONS OF PLUMBING FIXTURES AND SHOWER UNITS 1.4. FOR ALL PLUMBING AND FIXTURE PENETRATIONS FOR ALL PLUMBING AND FIXTURE PENETRATIONS THROUGH WALLS IN BATHROOMS AND SHOWER, SEAL WATER-TIGHT WITH WATER-PROOF CAULKING/SEALANT. 1.5. INCLUDE ALL VALVES, CONNECTIONS, ETC. FOR NEW INCLUDE ALL VALVES, CONNECTIONS, ETC. FOR NEW PLUMBING ASSEMBLIES. 2. GYPSUM BOARD, JOINT COMPOUND, AND INSULATION: GYPSUM BOARD, JOINT COMPOUND, AND INSULATION: 2.1. PROVIDE ASBESTOS-FREE MATERIALS. PROVIDE ASBESTOS-FREE MATERIALS. 2.2. PROVIDE GYP. BOARD WITH TAPERED EDGES AND PROVIDE GYP. BOARD WITH TAPERED EDGES AND JOINT COMPOUND CONFORMING TO ASTM C1396 C475, RESPECTIVELY. APPLY BOARDS TO FRAMING AND FURRING MEMBERS IN ACCORDANCE TO ASTM C840 OR GYPSUM ASSOCIATION (GA) 216. DO NOT FORCE PANELS IN PLACE, AND NEATLY FIT ABUTTING END AND EDGE JOINTS. CUT BOARD TO MAKE NEAT, CLOSE, AND TIGHT JOINTS AROUND OPENINGS. FOR VERTICAL SURFACES, PROVIDE PANELS IN ONE-CONTINUOUS LENGTH TO REACH FULL HEIGHT. 2.3. TREAT EDGES OF CUTOUTS FOR PLUMBING PIPES, TREAT EDGES OF CUTOUTS FOR PLUMBING PIPES, SCREW HEADS, AND JOINTS WITH WATER-RESISTANT COMPOUND AS RECOMMENDED BY THE MANUFACTURER. 2.4. TAPE AND FINISH GYP. BOARD IN ACCORDANCE WITH TAPE AND FINISH GYP. BOARD IN ACCORDANCE WITH ASTM C840, GA-214, AND GA-216. PROVIDE JOINT FASTENER DEPRESSION AND CORNER TREATMENT. TOOL JOINTS SMOOTHLY TO MINIMIZE SANDING AND DUST. USE SETTING OR HARDENING TYPE COMPOUNDS ONLY WITH CONVENTIONAL DRYING TYPE JOINT COMPOUNDS. 2.5. INSTALL MINIMUM 3 " SOUND ATTENUATION INSULATION. INSTALL MINIMUM 3 " SOUND ATTENUATION INSULATION. 12" SOUND ATTENUATION INSULATION. DELIVER MATERIALS TO SITE IN ORIGINAL SEALED WRAPPING BEARING MANUFACTURER'S NAME AND BRAND DESIGNATION, TYPE, GRADE, R-VALUE, AND CLASS. 3. DOORS AND FRAMES DOORS AND FRAMES 3.1. DOORS MUST BE 1 " THICK, UNLESS OTHERWISE DOORS MUST BE 1 " THICK, UNLESS OTHERWISE 34" THICK, UNLESS OTHERWISE NOTED. FORM FRAMES TO SIZES AND SHAPES INDICATED, WITH KNOCK-DOWN FIELD-ASSEMBLED 3.2. CORNERS. ENSURE ALL DOOR JAMBS ARE PROPERLY CORNERS. ENSURE ALL DOOR JAMBS ARE PROPERLY FRAMED AND REINFORCED FOR STRUCTURAL RIGIDITY AND PROPER DOOR OPERATION. ALL DOORS AND FRAMES MUST BE THOROUGHLY CLEANED, CHEMICALLY TREATED AND FACTORY PRIMED WITH A RUST INHIBITING COATING (FOR STEEL DOORS). 3.3. PROVIDE FINISHED DOORS AND FRAMES FREE FROM PROVIDE FINISHED DOORS AND FRAMES FREE FROM DEFECTS, WAVES, SCRATCHES, CUTS, DENTS, RIDGES, HOLES, WARP, AND BUCKLE. 3.4. INSTALL WALL-MOUNT DOOR STOPS FOR ALL NEW AND INSTALL WALL-MOUNT DOOR STOPS FOR ALL NEW AND EXISTING DOORS. 3.5. 6-PANEL, COMPOSITE DOORS, ULTRA-WHITE 6-PANEL, COMPOSITE DOORS, ULTRA-WHITE 4. FRAMING FRAMING 4.1. PROVIDE 2"X4" WOOD STUD FRAMING, DOUGLAS FIR. PROVIDE 2"X4" WOOD STUD FRAMING, DOUGLAS FIR. 4.2. USE WWPA G-5 STANDARD GRADING RULES, STANDARD USE WWPA G-5 STANDARD GRADING RULES, STANDARD LIGHT FRAMING OR NO. 3 STRUCTURAL LIGHT FRAMING (STUD GRADE FOR 2X4 NOMINAL SIZE, 10 FEET AND SHORTER). 4.3. INSTALL IN ACCORDANCE WITH THE NATIONAL INSTALL IN ACCORDANCE WITH THE NATIONAL ASSOCIATED OF HOME BUILDERS (NAHB) ADVANCED FRAMING TECHNIQUES: OPTIMUM VALUE ENGINEERING, UNLESS OTHERWISE SPECIFIED. 4.4. FIT FRAMING LUMBER AND OTHER ROUGH CARPENTRY, FIT FRAMING LUMBER AND OTHER ROUGH CARPENTRY, SET ACCURATELY TO THE REQUIRED LINES AND LEVELS, AND SECURE IN PLACE IN A RIGID MANNER. 4.5. PROVIDE AS NECESSARY FOR THE PROPER PROVIDE AS NECESSARY FOR THE PROPER COMPLETION OF THE WORK ALL FRAMING MEMBERS NOT INDICATED OR SPECIFIED. 4.6. PROVIDE SILLS (PRESSURE TREATED ON CONCRETE) AT PROVIDE SILLS (PRESSURE TREATED ON CONCRETE) AT ALL NEW WALL LOCATIONS. SET LEVEL AND SQUARE AND WEDGE WITH STEEL OR SLATE SHIMS. ANCHOR SILLS TO FOUNDATION. PROVIDE AT LEAST TWO BOLTS FOR EACH STILL MEMBER. PROVIDE MINIMUM ONE ON BOTTOM AND TWO TOP, CUT FROM SIMILAR DIMENSION LUMBER. 5. FLOORING FLOORING 5.1. FURNISH ALL MISCELLANEOUS MATERIALS, INCLUDING FURNISH ALL MISCELLANEOUS MATERIALS, INCLUDING REQUIRED FOR FLOORING INSTALLATION. 5.2. STORE ALL MATERIALS IN ORIGINAL PROTECTIVE STORE ALL MATERIALS IN ORIGINAL PROTECTIVE PACKAGING IN A SAFE, DRY, AND, CLEAN LOCATION. REPLACE DEFECTIVE OR DAMAGED MATERIALS. 5.3. FLOORING SUBSTRATE PREPARATION FLOORING SUBSTRATE PREPARATION 5.3.1. AFTER DEMOLITION, REPAIR AND PATCH EXISTING AFTER DEMOLITION, REPAIR AND PATCH EXISTING SUBFLOORING SURFACE TO ENSURE NEW FLOORING IS SOUND, FIRM, AND LEVEL. 5.3.2. USE LEVELING AND PATCHING COMPOUNDS AS USE LEVELING AND PATCHING COMPOUNDS AS RECOMMENDED BY THE FLOORING MANUFACTURER. 5.3.3. BROOM AND VACUUM CLEAN SUBSTRATES TO BE BROOM AND VACUUM CLEAN SUBSTRATES TO BE COVERED IMMEDIATELY BEFORE INSTALLING NEW FLOORING. OBTAIN COR APPROVAL OF SUBSTRATE SURFACE PRIOR TO INSTALLING FLOORING. 5.4. FOR BATHROOM AREAS, FLOORING MUST BE RATED FOR BATHROOM AREAS, FLOORING MUST BE RATED GREATER THAN OR EQUAL TO 0.42 DYNAMIC COEFFICIENT OF FRICTION (DCOF) IN ACCORDANCE WITH ANSI A137.1, SECTION 9.6. 5.5. PROVIDE TWO (2) EXTRA CASES OF VINYL FLOORING PROVIDE TWO (2) EXTRA CASES OF VINYL FLOORING TO COR. 5.5.0.1.1. 6. WINDOWS WINDOWS 6.1. FOR NEW WINDOWS, INSTALL NEW FRAME TO MATCH FOR NEW WINDOWS, INSTALL NEW FRAME TO MATCH COLOR AND MATERIAL OF EXISTING WINDOWS (UNLESS OTHERWISE INDICATED), AND DOUBLE GLAZING WITH LOCKING HANDLES AND SCREENS LOCATED ON THE SLIDING SIDE OF THE WINDOW. 6.2. WINDOWS MUST MEET ENERGY STAR CERTIFICATION FOR WINDOWS MUST MEET ENERGY STAR CERTIFICATION FOR NORTHERN CLIMATE ZONE, AND RECOMMENDED CAVITY WIDTH FOR "LOW E" STANDARDS, AND FILLED WITH INSULATING LAYER (DEHYDRATED AIR). CAVITIES FILLED WITH AN INERT GAS, SUCH AS ARGON, ARE NOT PERMITTED.
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
6/8 /20
:1
4 R
IC
HA
RD
RP
OL
AN
CO
C :\U
SE
RS
\R
IC
HA
RD
RP
OL
AN
CO
\D
ES
KT
OP
\R P\
PR
OJ
EC
TS
\Y
AQ
UI
H
OU
SE
R
EN
OV
AT
IO
N
AN
D
FL
OO
RI
NG
\1_
PR
E-
SO
LI
CI
TA
TI
ON
\D
RA
W
IN
GS
\E
XH
IB
IT
XX
_D
RA
W
IN
GS
.D W
G;
R3
SOUTHWESTERN REGION
SOUTH YAQUI HOUSE
REMODEL
APACHE-SITGREAVES
NATIONAL FORESTS
SPRINGERVILLE RANGER
DISTRICT
EQUIPMENT,
HARDWARE, & PAINT
SPECIFICATIONS
06/08/2020
R.POLANCO
R.POLANCO
C.MILLER
G-04
018004
SPECIFICATIONS
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text E
1. EQUIPMENT AND HARDWARE EQUIPMENT AND HARDWARE 1.1. INSTALL PER THE MANUFACTURER'S RECOMMENDATION. INSTALL PER THE MANUFACTURER'S RECOMMENDATION. 1.2. GRAB BARS GRAB BARS 1.2.1. SHALL NOT ROTATE WITHIN THEIR FITTINGS. SHALL NOT ROTATE WITHIN THEIR FITTINGS. 1.2.2. ALLOWABLE STRESSES SHALL NOT BE EXCEEDED ALLOWABLE STRESSES SHALL NOT BE EXCEEDED FOR MATERIALS USED WHEN A VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS IS APPLIED AT ANY POINT ON THE GRAB BAR, FASTENER, MOUNTING DEVICE, OR SUPPORTING STRUCTURE. 1.2.3. INSTALL BACKING, FRAMING, OR OTHER INSTALL BACKING, FRAMING, OR OTHER SUPPORT, AS NEEDED, FOR STRUCTURAL STRENGTH AND RIGIDITY. 1.2.4. CLOSETS, DOORS, AND BLINDS CLOSETS, DOORS, AND BLINDS 1.2.4.1. SPECIFIED MAKE AND MODEL ARE NOT SPECIFIED MAKE AND MODEL ARE NOT INTENDED TO BE THE EXACT SIZE NEEDED. INSTALL IN SPACE AS FIELD MEASURED. 1.2.5. BATHROOM FIXTURES AND ACCESSORIES BATHROOM FIXTURES AND ACCESSORIES 1.2.5.1. SEAL WATER TIGHT AROUND ALL ITEMS. SEAL WATER TIGHT AROUND ALL ITEMS. 1.3. COUNTERTOPS COUNTERTOPS 1.3.1. WRAP BACKSPLASH AT ALL WALL LOCATIONS. WRAP BACKSPLASH AT ALL WALL LOCATIONS. 1.3.2. 3/8" DOUBLE RADIUS EDGING 3/8" DOUBLE RADIUS EDGING 1.3.3. FOR COUNTERTOPS EXTENDING FOR SEATING, FOR COUNTERTOPS EXTENDING FOR SEATING, INSTALL BRACING UNDER COUNTERTOP AS REQUIRED. 1.4. CASEWORK CASEWORK 1.4.1. CABINETS SHALL HAVE TWO ADJUSTABLE CABINETS SHALL HAVE TWO ADJUSTABLE SHELVES PER CABINET. 1.4.1.1. NOT APPLICABLE FOR BATHROOM AREAS. NOT APPLICABLE FOR BATHROOM AREAS. 1.4.2. SOFT CLOSED DRAWERS AND CABINET DOORS. SOFT CLOSED DRAWERS AND CABINET DOORS. 1.4.3. FULL EXTENSION DRAWERS. FULL EXTENSION DRAWERS. 1.4.4. SOLID MAPLE DOVE TAIL DRAWER BOXES. SOLID MAPLE DOVE TAIL DRAWER BOXES. 1.4.5. INSTALL 4-INCH VERTICAL, RECESSED TOE KICKS INSTALL 4-INCH VERTICAL, RECESSED TOE KICKS AT ALL LOCATIONS. 1.4.6. DOOR STYLES DOOR STYLES 1.4.6.1. KITCHEN - HIGHLAND DOOR STYLE KITCHEN - HIGHLAND DOOR STYLE 1.4.6.2. BATHROOMS - MILL CREEK DOOR STYLE BATHROOMS - MILL CREEK DOOR STYLE 2. INTERIOR PAINTING INTERIOR PAINTING 2.1. PREPARATION PREPARATION 2.1.1. COMPLY WITH RECOMMENDATIONS IN THE MASTER COMPLY WITH RECOMMENDATIONS IN THE MASTER PAINTER'S INSTITUTE (MPI) "MPI ARCHITECTURAL PAINTING SPECIFICATION MANUAL" APPLICABLE TO SUBSTRATES INDICATED. 2.1.2. REMOVE HARDWARE, LIGHTING FIXTURES, AND REMOVE HARDWARE, LIGHTING FIXTURES, AND SIMILAR ITEMS THAT ARE NOT TO BE PAINTED. MASK ITEMS THAT CANNOT BE REMOVED. REINSTALL ITEMS IN EACH AREA AFTER PAINTING IS COMPLETE. 2.1.3. REMOVE ALL WALL AND CEILING HOOKS, REMOVE ALL WALL AND CEILING HOOKS, FASTENERS, NAILS, ETC. AND PATCH DAMAGED AREAS PRIOR TO PAINT. 2.1.4. CLEAN AND PREPARE SURFACES IN AN AREA CLEAN AND PREPARE SURFACES IN AN AREA BEFORE BEGINNING PAINTING IN THAT AREA. SCHEDULE PAINTING SO CLEANING OPERATIONS WILL NOT DAMAGE NEWLY PAINTED SURFACES. 2.1.5. OBTAIN COR APPROVAL OF PREPPED INTERIOR OBTAIN COR APPROVAL OF PREPPED INTERIOR PRIOR TO PROCEEDING WITH PRIMER AND PAINT. 2.2. PAINT EXPOSED NEW AND EXISTING SURFACES, PAINT EXPOSED NEW AND EXISTING SURFACES, UNLESS OTHERWISE INDICATED. 2.2.1. DO NOT PAINT PRE-FINISHED ITEMS. DO NOT PAINT PRE-FINISHED ITEMS. 2.3. APPLY PAINTS TO PRODUCE SURFACE FILMS WITHOUT APPLY PAINTS TO PRODUCE SURFACE FILMS WITHOUT CLOUDINESS, SPOTTING, HOLIDAYS, LAPS, BRUSH MARKS, ROLLER TRACKING, RUNS, SAGS, ROPINESS, OR OTHER SURFACE IMPERFECTIONS. CUT IN SHARP LINES AND COLOR BREAKS 2.4. IF UNDERCOATS OR OTHER CONDITIONS SHOW IF UNDERCOATS OR OTHER CONDITIONS SHOW THROUGH TOPCOAT, APPLY ADDITIONAL COATS UNTIL CURED FILM HAS A UNIFORM PAINT FINISH, COLOR, AND APPEARANCE. 2.5. FINAL FINISH FINAL FINISH 2.5.1. GLOSS LEVEL 2, INSTITUTIONAL LOW-ODOR/VOC GLOSS LEVEL 2, INSTITUTIONAL LOW-ODOR/VOC LATEX, ONE COAT OVER LOW-ODOR/VOC PRIMER/SEALER, MPI INT 9.2.M. 2.5.1.1. NON-ACCENT WALLS AND CEILINGS: BEHR NON-ACCENT WALLS AND CEILINGS: BEHR CAMEO WHITE, MQ3-32. 2.5.1.2. ACCENT WALLS: BEHR MOCHA LIGHT, ACCENT WALLS: BEHR MOCHA LIGHT, BWC-24. 2.5.2. FOR UNFINISHED (PRIMED) CLOSET AND FOR UNFINISHED (PRIMED) CLOSET AND INTERIOR DOORS, PAINT BEHR ULTRA PURE WHITE. 3. EXTERIOR PAINTING EXTERIOR PAINTING 3.1. PREPARATION PREPARATION 3.1.1. REMOVE LOSE PAINT, DEBRIS, ETC. REMOVE LOSE PAINT, DEBRIS, ETC. 3.1.2. RE-CAULK EXTERIOR TRIM AS NEEDED, RE-CAULK EXTERIOR TRIM AS NEEDED, INCLUDING WINDOWS, DOORS, ETC. 3.1.3. PATCH HOLES AS NEEDED. PATCH HOLES AS NEEDED. 3.1.4. SAND AND CLEAN SURFACES RECEIVING PRIMER SAND AND CLEAN SURFACES RECEIVING PRIMER AND PAINT. 3.1.5. COMPLY WITH SECTION 2.1, "INTERIOR PAINTING COMPLY WITH SECTION 2.1, "INTERIOR PAINTING - PREPARATION," AS APPLICABLE. 3.1.6. OBTAIN COR APPROVAL OF PREPPED EXTERIOR OBTAIN COR APPROVAL OF PREPPED EXTERIOR PRIOR TO PROCEEDING WITH PRIMER AND PAINT. 3.2. COMPLY WITH SECTIONS 1.3 AND 1.4 UNDER COMPLY WITH SECTIONS 1.3 AND 1.4 UNDER INTERIOR PAINTING FOR APPLICATION. 3.3. DO NOT PAINT OVER ROOF METAL/FLASHING. DO NOT PAINT OVER ROOF METAL/FLASHING. 3.4. FINAL FINISH FINAL FINISH 3.4.1. SATIN FINISH, LATEX, TWO COATS OVER LATEX SATIN FINISH, LATEX, TWO COATS OVER LATEX PRIMER: MPI EXT 6.3L. 3.4.1.1. WALLS (INCLUDING SOFFIT): BEHR MESA WALLS (INCLUDING SOFFIT): BEHR MESA TAUPE, PPU5-14. 3.4.1.2. TRIM (AROUND WINDOWS, DOORS): BEHR TRIM (AROUND WINDOWS, DOORS): BEHR CHOCOLATE SWIRL, PPU5-18.
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
6/8 /20
:1
4 R
IC
HA
RD
RP
OL
AN
CO
C :\U
SE
RS
\R
IC
HA
RD
RP
OL
AN
CO
\D
ES
KT
OP
\R P\
PR
OJ
EC
TS
\Y
AQ
UI
H
OU
SE
R
EN
OV
AT
IO
N
AN
D
FL
OO
RI
NG
\1_
PR
E-
SO
LI
CI
TA
TI
ON
\D
RA
W
IN
GS
\E
XH
IB
IT
XX
_D
RA
W
IN
GS
.D W
G;
R3
SOUTHWESTERN REGION
SOUTH YAQUI HOUSE
REMODEL
APACHE-SITGREAVES
NATIONAL FORESTS
SPRINGERVILLE RANGER
DISTRICT
ELECTRICAL
SPECIFICATIONS
06/08/2020
R.POLANCO
R.POLANCO
C.MILLER
G-05
018005
SPECIFICATIONS
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text E
1. ELECTRICAL ELECTRICAL 1.1. GENERAL GENERAL 1.1.1. LOCATIONS AND REQUIREMENTS OUTLINED HEREIN LOCATIONS AND REQUIREMENTS OUTLINED HEREIN ARE CONSIDERED APPROXIMATE. CONTRACTOR IS REQUIRED TO COMPLY WITH THE LATEST VERSION OF NFPA 70 FOR PERFORMING ALL ELECTRICAL WORK. RELOCATE ELECTRICAL LOCATIONS AS REQUIRED TO MEET CODE. 1.1.2. UPDATE EXISTING CIRCUIT BREAKER PANELS WITH UPDATE EXISTING CIRCUIT BREAKER PANELS WITH NEW LAMINATED LABELING. TEST AND VERIFY EXISTING CIRCUITS TO ACCURATE UPDATE CIRCUIT BREAKER LABELING. 1.1.3. GROUND AND BOND, AS REQUIRED BY NFPA 70, GROUND AND BOND, AS REQUIRED BY NFPA 70, ALL NEW ELECTRICAL WORK. 1.2. LOW VOLTAGE ELECTRICAL POWER CONDUCTORS AND LOW VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES 1.2.1. USE PULLING MEANS, INCLUDING FISH TABLE, USE PULLING MEANS, INCLUDING FISH TABLE, CABLE, ROPE, AND BASKET-WEAVE WIRE/CABLE GRIPS, THAT WILL NOT DAMAGE CABLES OR RACEWAY. USE MANUFACTURER-APPROVED PULLING COMPOUND OR LUBRICANT WHERE NECESSARY. 1.2.2. MAKE SPLICES, TERMINATIONS, AND TAPS THAT MAKE SPLICES, TERMINATIONS, AND TAPS THAT ARE COMPATIBLE WITH CONDUCTOR MATERIAL. 1.2.3. INSTALL CONDUCTOR AT EACH OUTLET, WITH AT INSTALL CONDUCTOR AT EACH OUTLET, WITH AT LEAST 6 INCHES OF SLACK. 1.2.4. INSTALL SLEEVES AND SLEEVE SEALS AT INSTALL SLEEVES AND SLEEVE SEALS AT PENETRATIONS OF EXTERIOR FLOOR AND WALL ASSEMBLIES. 1.2.5. TIGHTEN ELECTRICAL CONNECTORS AND TIGHTEN ELECTRICAL CONNECTORS AND TERMINALS ACCORDING TO MANUFACTURER'S PUBLISH TORQUE-TIGHTENING VALUES. IF MANUFACTURER'S VALUES ARE NOT INDICATED, USE THOSE SPECIFIED IN UL 486A-486B. 1.2.6. FIELD QUALITY CONTROL FIELD QUALITY CONTROL 1.2.1.1. AFTER INSTALLING CONDUCTORS AND AFTER INSTALLING CONDUCTORS AND CABLES AND BEFORE ELECTRICAL CIRCUITRY HAS BEEN ENERGIZED, TEST CONDUCTORS FEEDING ALL NEW EQUIPMENT AND SERVICES FOR COMPLIANCE WITH REQUIREMENTS. CABLES WILL BE CONSIDERED DEFECTIVE IF THEY DO NOT PASS TESTS AND INSPECTIONS. 1.3. WIRING DEVICES WIRING DEVICES 1.3.1. DEVICES COLOR: WIRING DEVICES CONNECTED TO DEVICES COLOR: WIRING DEVICES CONNECTED TO NORMAL POWER SYSTEMS SHALL BE WHITE UNLESS OTHERWISE INDICATED OR REQUIRED BY NFPA 70 OR DEVICE LISTING. 1.3.2. CONVENIENCE RECEPTACLES: NEMA WD-1, NEMA CONVENIENCE RECEPTACLES: NEMA WD-1, NEMA WD-6, CONFIGURATION 5-20R, AND UL 498. 1.3.3. DUPLEX GROUND-FAULT CIRCUIT-INTERRUPTER DUPLEX GROUND-FAULT CIRCUIT-INTERRUPTER (GFCI) CONVENIENCE RECEPTACLES: 125-V, 20-A, STRAIGHT BLADE, FEED-THROUGH TYPE, NEMA WD-1, NEMA WD-6, UL 498, AND UL 943, CLASS A, AND INCLUDE INDICATOR LIGHT THAT IS LIGHTED WHEN DEVICE IS TRIPPED. 1.3.4. TOGGLE SWITCHES: NEMA WD-1 AND UL 20, TOGGLE SWITCHES: NEMA WD-1 AND UL 20, SINGLE-POLE, 120/277V, 20A. 1.3.5. WALL-BOX DIMMERS WALL-BOX DIMMERS 1.3.5.1. MODULAR, FULL-WAVE, SOLID-STATE UNITS MODULAR, FULL-WAVE, SOLID-STATE UNITS WITH INTEGRAL, QUIET ON-OFF SWTICHES WITH AUDIBLE FREQUENCY AND EMI/RFI SUPPRESSION FILTERS. 1.3.5.2. CONTINUOUSLY ADJUSTABLE SLIDER CONTINUOUSLY ADJUSTABLE SLIDER CONTROL WITH SINGLE-POLE OR THREE-WAY SWITCHING, COMPLYING WITH UL 1472. 1.3.6. WALL PLATES WALL PLATES 1.3.6.1. SMOOTH, HIGH-IMPACT THERMOPLASTIC, SMOOTH, HIGH-IMPACT THERMOPLASTIC, WHITE, FASTENED WITH METAL SCREWS HAVING HEADS MATCHING PLATE COLOR. 1.3.6.2. FOR DAMP AREAS, THERMOPLASTIC AND FOR DAMP AREAS, THERMOPLASTIC AND LISTED AND LABELED FOR USE IN DAMP AREAS. 1.3.7. DO NOT USE OVERSIZED OR EXTRA-DEEP DO NOT USE OVERSIZED OR EXTRA-DEEP PLATES. REPAIR WALL FINISHES AND REMOUNT OUTLET BOXES WHEN STANDARD DEVICE PLATES DO NOT FLUSH OR COVER ROUGH WALL OPENING. 1.3.8. MOUNT DEVICES FLUSH, WITH LONG DIMENSION MOUNT DEVICES FLUSH, WITH LONG DIMENSION VERTICAL, AND GROUNDING TERMINAL OF RECEPTACLES ON TOP UNLESS OTHERWISE INDICATED. GROUP ADJACENT DEVICES UNDER SINGLE, MULTI-GANG WALL PLATES. 1.3.9. INSTALL UNSHARED NEUTRAL CONDUCTORS ON INSTALL UNSHARED NEUTRAL CONDUCTORS ON LINE AND LOAD SIDE OF DIMMERS. 1.4. RACEWAYS AND BOXES RACEWAYS AND BOXES 1.4.1. METAL CONDUITS, TUBING, AND FITTINGS SHALL METAL CONDUITS, TUBING, AND FITTINGS SHALL SHALL BE LISTED AND LABELED AS DEFINED IN NFPA 70, BY A QUALIFIED TESTING AGENCY, AND MARKED FOR INTENDED LOCATION AND APPLICATION. 1.4.2. FLEXIBLE METAL CONDUIT (FMC): COMPLY WITH FLEXIBLE METAL CONDUIT (FMC): COMPLY WITH UL 1, ALUMNIMUM, WITH FITTINGS SPECIFICALLY DESIGNED FOR USE WITH FMC. 1.4.3. ELECTRICAL METALLIC TUBING (EMT): COMPLY ELECTRICAL METALLIC TUBING (EMT): COMPLY WITH ANSI C80.3 AND UL 797. 1.4.4. INTERMEDIATE METAL CONDUIT (IMC): FOR USE INTERMEDIATE METAL CONDUIT (IMC): FOR USE IN INDOOR WET/DAMP LOCATIONS, COMPLY WITH ANSI C80.6 AND UL 1242, GALVANIZED. 1.4.5. OUTLET AND DEVICE BOXES: CAST-METAL, OUTLET AND DEVICE BOXES: CAST-METAL, FERROUS ALLOY, TYPE FD, WITH GASKETED COVER, NEMA FB-1 AND NEMA OS-1, AND MIN. 1-1/2" DEEP. FURNISH ALL PULL AND JUNCTION BOXES WITH SCREW-FASTENED COVERS. 1.4.6. INSTALL RACEWAYS AND CABLES CONCEALED IN INSTALL RACEWAYS AND CABLES CONCEALED IN FINISHED WALLS, CEILINGS, AND FLOORS UNLESS OTHERWISE INDICATED. . 1.4.7. INSTALL HANGERS AND SUPPORTS AS REQUIRED INSTALL HANGERS AND SUPPORTS AS REQUIRED FOR RACEWAY APPLICATION, AND SEPARATE DISSIMILAR METALS AND METAL PRODUCTS FROM CONTACT WITH WOOD OR CEMENTITIOUS MATERIALS BY PAINTING EACH METAL SURFACE IN AREA OF CONTACT WITH A BITUMINOUS COATING OR BY OTHER PERMANENT SEPARATION. 1.4.8. INSTALL PULL WIRES IN EMPTY RACEWAYS. INSTALL PULL WIRES IN EMPTY RACEWAYS. 1.5. LIGHTING LIGHTING 1.5.1. FURNISH ALL MATERIALS TO COMPLETE FURNISH ALL MATERIALS TO COMPLETE INSTALLATION OF LIGHTING. SET FIXTURES PLUMB, SQUARE, AND LEVEL WITH CEILINGS AND WALLS, IN ALIGNMENT WITH ADJACENT LIGHT FIXTURES, WITH ALL NEW LIGHTING CONTROLS. 1.5.2. SECURE IN ACCORDANCE WITH MANUFACTURER'S SECURE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND NFPA 70.
1 1
DEMO LEGEND (REMOVE)
WALL (DEMO)
1 DEMO DOOR
2 DEMO WAINSCOTINGLIGHT FIXTURE
3 DEMO CLOSET DOORS, TRACKS, ETC.
KEYED NOTES
3 3
REMOVE STEEL TUB,
WALL SUBWAY TILE,
AND SHOWER/BATH
FIXTURES. INCLUDE
REMOVAL OF GYP.
BOARD FOR NEW
SCHLUTER BOARD
REMOVE VANITY/SINK
LAYERED FLOOR /
CARPET / TILE
C E F G
B J I H
A
D
4 DEMO ALL CLOSET SHELVES,
RODS, GYP. BOARD, ETC.
KITCHEN/BATHROOM
TILE
SALVAGE AND
RELOCATE TOILET
REMOVE WOOD STOVE, PIPING,
AND BRICK WALL
REMOVE SLIDING
POCKET DOOR AND
FRAME
RELOCATE IN-FLOOR
HEATING LOCATION
RELOCATE
RECEPTACLE
RELOCATE DUPLEX
RECEPTACLE
EXISTING DUPLEX
RECEPTACLE
REMOVE WINDOW
OPTION: REMOVE ALL OPAQUE
WINDOWS LOCATED ABOVE
WALL AND REPLACE WITH
DUAL-PANE, ENERGY STAR
FIXED WINDOWS (NO SCREENS
REQUIRED)
5 DEMO KITCHEN, INCLUDING ALL
CABINETS, COUNTERTOPS, SINK,
GARBAGE DISPOSAL, DISHWASHER.
REMOVE SWITCHES, RECEPTACLES,
AND WIRING BACK TO PANEL
DEMO FURRED DOWN WALLS
AT EXISTING HANGING CABINET
LOCATIONS AND POCKET
SLIDING DOOR LOCATION (MAY RELOCATE
RECEPTACLE FOR NEW LOCATION)
EXISTING RECEPTACLE TO
REMAIN IN NEW DIVIDING
WALL
DRAWING TITLE
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
6/8 /20
:1
4 R
IC
HA
RD
RP
OL
AN
CO
C :\U
SE
RS
\R
IC
HA
RD
RP
OL
AN
CO
\D
ES
KT
OP
\R P\
PR
OJ
EC
TS
\Y
AQ
UI
H
OU
SE
R
EN
OV
AT
IO
N
AN
D
FL
OO
RI
NG
\1_
PR
E-
SO
LI
CI
TA
TI
ON
\D
RA
W
IN
GS
\E
XH
IB
IT
XX
_D
RA
W
IN
GS
.D W
G;
R3
SOUTHWESTERN REGION
SOUTH YAQUI HOUSE
REMODEL
APACHE-SITGREAVES
NATIONAL FORESTS
SPRINGERVILLE RANGER
DISTRICT
DEMO PLAN
06/08/2020
R.POLANCO
R.POLANCO
C.MILLER
A-01
0180064' 8'2'0
SCALE
1" = 4'
1'
SHEET NOTES
1. DEMO ALL LAYERS OF FLOORING (INC. ADHESIVE) TO CONCRETE (CARPET, CARPET, PAD,
AND 9X9 TILE FOR ALL ROOMS OTHER THAN ROOMS A AND J, WHICH HAVE ONE LAYER TILE).
2. DEMO ALL LIGHT FIXTURES (INCL. TWO (2) EXTERIOR AND ONE (1) SECURITY LIGHT).
3. DEMO ALL BASE BOARD WHERE FLOORING IS BEING REMOVED.
4. FOR ROOMS I AND H (BATHROOMS), REMOVE MEDICINE CABINETS, MIRRORS, TOILET
PAPER HOLDERS, AND ALL OTHER ACCESSORIES.
5 REMOVE ALL WINDOW CURTAINS, RODS, AND ACCESSORIES.
6. REMOVE ALL WALL AND CEILING HOOKS, NAILS, ETC. IN PREPARATION FOR PAINT.
7. REMOVE ALL 21
2" X 14" REGISTERS, AND 7"X12" REGISTERS IN BATHROOMS
8. REMOVE ALL LIGHT SWITCHES/PLATES AND
DUPLEX WALL PLATES.
9. DEMO ALL GYP. BOARD IN ROOM G AREAS TO NEW
BATHROOM EXTENTS.
N
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
E
C E F G
B J I H
D
LEGEND
NEW FLOOR TO
CEILING WALL
NEW DIVIDING
WALL
A DRAWING TITLE
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
6/8 /20
:1
4 R
IC
HA
RD
RP
OL
AN
CO
C :\U
SE
RS
\R
IC
HA
RD
RP
OL
AN
CO
\D
ES
KT
OP
\R P\
PR
OJ
EC
TS
\Y
AQ
UI
H
OU
SE
R
EN
OV
AT
IO
N
AN
D
FL
OO
RI
NG
\1_
PR
E-
SO
LI
CI
TA
TI
ON
\D
RA
W
IN
GS
\E
XH
IB
IT
XX
_D
RA
W
IN
GS
.D W
G;
R3
SOUTHWESTERN REGION
SOUTH YAQUI HOUSE
REMODEL
APACHE-SITGREAVES
NATIONAL FORESTS
SPRINGERVILLE RANGER
DISTRICT
REMODEL LAYOUT
NEW DIMENSIONS
06/08/2020
R.POLANCO
R.POLANCO
C.MILLER
A-02
018007
N
4' 8'2'0
SCALE
1" = 4'
1'
5'-10"
1'-
12'-5"
9'-10"
2'-3"
6'-3"
3'-5"
5'-10"
4'-4"
10'-1"
1'-9"
5'-5"
1'-9"
4'-0"
7'-9"
2'-0"
2'-5"
2'-0"
2'-0"
4'-2"
4'-0"
4'-0"
3'-0"
5'-9"
8'-4"
1'-4"
2'-8"
2'-5"
8'-71 2"
3'-2"
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
REQ'D CLEAR
SPACE
REQ'D CLEAR
SPACE
D1
D3
1 NOT USED
3 INSTALL BIFOLD LOUVERED CLOSET DOORS
KEYED NOTES
4 INSTALL BIFOLD 6-PANEL CLOSET DOORS
5 ACCENT WALL, BEHR MOCHA LIGHT, BWC-24
SMALLER DOOR THAN SCHEDULE;
FIELD MEASURE
NEW SINK,
DRAWERS,
AND COUNTERTOP
LEGEND
NEW FLOOR TO
CEILING WALL
NEW DIVIDING
WALL
NEW TOILET
LOCATION
GRAB BARS,
2" DIA. (TYP.)
C E F G
B J I
H
D
CONTROL WALL; INSTALL NEW
SHOWER HEAD, LEVER, AND
BATH FAUCET WITH SAME
ELEVATIONS AS ROOM H
4 4 4
RELOCATE TO
THIS LOCATION
RELOCATE RECEPTACLE
TO THIS LOCATION
RELOCATE DUPLEX
RECEPTACLE TO THIS
LOCATION
EXISTING DUPLEX
RECEPTACLE
INSTALL GOVERNMENT-FURNISHED PELLET STOVE.
RUN ELECTRICAL FROM NEAREST POWER SOURCE
TO STOVE, AND INSTALL NEW SWITCH. INSTALL NEW
STOVE PIPING AS REQUIRED BY CODE TO THE
EXISTING CEILING LOCATION
5 5 5 5
6 BATH/SHOWER COMBO UNIT
7 NEW 12"X24" SLIDING WINDOW WITH FROSTED FILM,
DUAL-PANE, INSULATING AIR LAYER, WITH ADDITIONAL STUD
SUPPORT AS NEEDED
INSTALL HEARTH PAD PER
MANUFACTURER'S
INSTRUCTIONS AND THIN-SET
MORTAR ON CONCRETE
OPTIONAL FLOOR TO WINDOW
ROCKWORK
USE EXISTING FRESH AIR INTAKE
LOCATION AND PIPE TO NEW
STOVE PER MANUFACTURER'S
INSTRUCTIONS
D3D3
D2
INSTALL SHELVES, ROD, ETC.
PER SETUP IN ROOMS E AND F
D4
D5
A
CABINETS AND COUNTERTOP
KITCHEN ISLAND
INSTALL 4"X4" COLUMN TO
SUPPORT MAIN BEAM (REFER TO
AS-BUILTS), DRYWALL, TEXTURED,
AND PAINTED (TYP.)
COUNTERTOP; ON TOP OF DIVIDING
WALL AND EXTEND FOR SEATING
AS SHOWN, 42" AFF. CUT AS
NEEDED TO TO WRAP AROUND
NEW COLUMNS.
DIVIDING WALL,
40.5" AFF
DRAWING TITLE
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
6/8 /20
:1
4 R
IC
HA
RD
RP
OL
AN
CO
C :\U
SE
RS
\R
IC
HA
RD
RP
OL
AN
CO
\D
ES
KT
OP
\R P\
PR
OJ
EC
TS
\Y
AQ
UI
H
OU
SE
R
EN
OV
AT
IO
N
AN
D
FL
OO
RI
NG
\1_
PR
E-
SO
LI
CI
TA
TI
ON
\D
RA
W
IN
GS
\E
XH
IB
IT
XX
_D
RA
W
IN
GS
.D W
G;
R3
SOUTHWESTERN REGION
SOUTH YAQUI HOUSE
REMODEL
APACHE-SITGREAVES
NATIONAL FORESTS
SPRINGERVILLE RANGER
DISTRICT
REMODEL FLOOR
PLAN
06/08/2020
R.POLANCO
R.POLANCO
C.MILLER
A-03
018008
N
4' 8'2'0
SCALE
1" = 4'
1'
SHEET NOTES
1. INSTALL NEW 2" WOOD FAUX BLINDS FOR ALL WINDOWS, EXCLUDING BATHROOMS AND THE
OPAQUE DECORATIVE WINDOWS IN ROOMS B AND C. INCLUDE HEAD RAIL AND END CAP.
2. IN ROOM H, INSTALL SEWER TO NEW TOILET, BATHTUB, AND SINK LOCATIONS BY
TRENCHING AND INSTALL OUTSIDE OF THE BUILDING TO SEWER LOCATIONS JUST NORTH OF
ROOMS I AND H (CLEANOUTS ARE VISIBLE). INSTALL CLEANOUTS PER CODE.
3. CAP/ABANDON EXISTING TOILET SEWER/DRAIN IN ROOM H.
4. IN ROOM H, INSTALL NEW PEX PLUMBING FROM EXISTING LOCATIONS TO NEW PLUMBING
FIXTURES (RED FOR HOT LINE AND BLUE FOR COLD LINES).
5. REPLACE ALL 2-1/2"X14" HVAC FLOOR REGISTERS WITH NEW, BLACK REGISTERS. REPLACE
7"X12" BATHROOM REGISTERS WITH NEW, ULTRA WHITE
REGISTERS.
6. PREP, PRIME, AND PAINT ALL CEILINGS AND WALLS.
7. PREP, PRIME, AND PAINT HOUSE EXTERIOR.
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text A-06
AutoCAD SHX Text
AutoCAD SHX Text A-06
AutoCAD SHX Text
AutoCAD SHX Text A-06
GRAB
BARS (TYP.)
TOWEL
BAR
TOILET PAPER
HOLDER
RECESSED MIRRORED
MEDICINE CABINET
RELOCATED AFCI/GFCI PROTECTED
DUPLEX RECEPTACLE
EAST WALL NORTH WALL
WEST WALL SOUTH WALL
VANITY LIGHT
FIXTURE
MIRROR
12" x 24"
SLIDING WINDOW
DRAWERS AS
SHOWN
RELOCATE REGISTER/DUCT TO
THIS LOCATION
EXISTING REGISTER
LOCATION
ACCESSIBLE SPACE; SEE
DETAIL 1B, SHEET A-10
DIVIDING
WALL
LAMINATE COUNTERTOP
WITH BACKSPLASH
CURTAIN ROD
DRAWING TITLE
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
6/8 /20
:1
4 R
IC
HA
RD
RP
OL
AN
CO
C :\U
SE
RS
\R
IC
HA
RD
RP
OL
AN
CO
\D
ES
KT
OP
\R P\
PR
OJ
EC
TS
\Y
AQ
UI
H
OU
SE
R
EN
OV
AT
IO
N
AN
D
FL
OO
RI
NG
\1_
PR
E-
SO
LI
CI
TA
TI
ON
\D
RA
W
IN
GS
\E
XH
IB
IT
XX
_D
RA
W
IN
GS
.D W
G;
R3
SOUTHWESTERN REGION
SOUTH YAQUI HOUSE
REMODEL
APACHE-SITGREAVES
NATIONAL FORESTS
SPRINGERVILLE RANGER
DISTRICT
ROOM H ELEVATION
VIEWS
06/08/2020
R.POLANCO
R.POLANCO
C.MILLER
A-04
0180092' 4'1'0
SCALE
1" = 2'
6"
ROOM H
3'-0" 6'-4"
4"
2'-4"
7"
2'-0"
3'-111 2"
2'-2" 2'-11" 2'-3"
4"
4"
4'-1" 4'-9"
1'-9" 3'-0"
2'-7"
4" 3'-7"
3'-0"
6"
1'-0" 1'-0"
7"
1'-9"
7'-0"3'-0"1'-10"
2'-10"
3'-7" 2'-0"
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
TOILET TO
REMAIN
VANITY LIGHT
FIXTURE
MIRROR
DRAWERS AND
CABINETS AS
SHOWN
TOILET PAPER
HOLDER
TOWEL BAR
BATH/SHOWER
COMBO UNIT
(BACK WALL)
EXISTING WINDOW
(TO REMAIN)
REPLACE
REGISTER
NORTH WALL EAST WALL
CURTAIN ROD
DRAWING TITLE
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
6/8 /20
:1
4 R
IC
HA
RD
RP
OL
AN
CO
C :\U
SE
RS
\R
IC
HA
RD
RP
OL
AN
CO
\D
ES
KT
OP
\R P\
PR
OJ
EC
TS
\Y
AQ
UI
H
OU
SE
R
EN
OV
AT
IO
N
AN
D
FL
OO
RI
NG
\1_
PR
E-
SO
LI
CI
TA
TI
ON
\D
RA
W
IN
GS
\E
XH
IB
IT
XX
_D
RA
W
IN
GS
.D W
G;
R3
SOUTHWESTERN REGION
SOUTH YAQUI HOUSE
REMODEL
APACHE-SITGREAVES
NATIONAL FORESTS
SPRINGERVILLE RANGER
DISTRICT
ROOM I ELEVATION
VIEWS
06/08/2020
R.POLANCO
R.POLANCO
C.MILLER
A-05
0180102' 4'1'0
SCALE
1" = 2'
6"
SHEET NOTES
1. FOR ALL WET AREAS IN ROOMS H AND I (BEHIND NEW BATH/SHOWER
COMBO UNIT), REMOVE ALL EXISTING GYP. BOARD AND REPLACE WITH
SHLUTER BOARD.
ROOM I
2'-7"
4'-0"
4"
4'-1"
3'-0" 1'-0"
6'-4"
2'-0" 3'-10"
2'-10"
6"
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
RE-WIRE SWITCH
TO GARBAGE
DISPOSAL (CURRENTLY
NOT FUNCTIONING)
RELOCATE
KITCHEN LIGHT
SWITCH TO
NEW LOCATION
REMOVE CEILING VENT
AND SWITCHING, WIRING,
ETC.
NEW GARBAGE
DISPOSAL
NEW SINKNEW OVER THE
RANGE MICROWAVE
AND ASSOCIATED
ELECTRICAL INSTALL DISH WASHER
INSTALL 20A DEDICATED
CIRCUIT FOR REFRIGERATOR;
RELOCATE EXISTING WIRING/
RECEPTACLE FROM OLD
REFRIGERATOR LOCATION IS
ACCEPTABLE
EXISTING
WINDOW
NEW WALL CABINETS
AS SHOWN
NEW
COUNTERTOP
WITH BACKSPLASH
KITCHEN ISLAND WITH
CASEWORK AND COUNTERTOP
AS SHOWN
NEW 4X4 COLUMN
EXISTING 2X12 BEAMS
EXISTING
TELEPHONE
JACK
DRAWING TITLE
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
6/8 /20
:1
4 R
IC
HA
RD
RP
OL
AN
CO
C :\U
SE
RS
\R
IC
HA
RD
RP
OL
AN
CO
\D
ES
KT
OP
\R P\
PR
OJ
EC
TS
\Y
AQ
UI
H
OU
SE
R
EN
OV
AT
IO
N
AN
D
FL
OO
RI
NG
\1_
PR
E-
SO
LI
CI
TA
TI
ON
\D
RA
W
IN
GS
\E
XH
IB
IT
XX
_D
RA
W
IN
GS
.D W
G;
R3
SOUTHWESTERN REGION
SOUTH YAQUI HOUSE
REMODEL
APACHE-SITGREAVES
NATIONAL FORESTS
SPRINGERVILLE RANGER
DISTRICT
ROOM A (KITCHEN)
ELEVATION VIEWS
06/08/2020
R.POLANCO
R.POLANCO
C.MILLER
A-06
0180112' 4'1'0
SCALE
1" = 2'
6"
SHEET NOTES
1. PLUMB NEW WATER LINE TO REFRIGERATOR LOCATION. CONNECT IF
REFRIGERATOR AND INSTALLATION OPTION IS AWARDED.
ROOM A
SECTION 1 - WEST WALL
SECTION 3 - EAST WALL
SECTION 2 - NORTH WALL
4'-2"
3'-6"3'-0"
3'-0"
3"
5'-0"
2'-6"
2'-2"
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
FLOORING (NEW)
1 NOT USED
KEYED NOTES
VINYL PLANK
FLOORING, BASE
BOARD, AND
MOULDING
DRAWING TITLE
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
6/8 /20
:1
4 R
IC
HA
RD
RP
OL
AN
CO
C :\U
SE
RS
\R
IC
HA
RD
RP
OL
AN
CO
\D
ES
KT
OP
\R P\
PR
OJ
EC
TS
\Y
AQ
UI
H
OU
SE
R
EN
OV
AT
IO
N
AN
D
FL
OO
RI
NG
\1_
PR
E-
SO
LI
CI
TA
TI
ON
\D
RA
W
IN
GS
\E
XH
IB
IT
XX
_D
RA
W
IN
GS
.D W
G;
R3
SOUTHWESTERN REGION
SOUTH YAQUI HOUSE
REMODEL
APACHE-SITGREAVES
NATIONAL FORESTS
SPRINGERVILLE RANGER
DISTRICT
NEW FLOORING
06/08/2020
R.POLANCO
R.POLANCO
C.MILLER
A-07
018012
N
4' 8'2'0
SCALE
1" = 4'
1'
SHEET NOTES
1. LIMIT BASEBOARD REMOVAL DAMAGE TO THE MOST PRACTICAL EXTENT. SKIM AND TEXTURE AS
NEEDED TO RECEIVE NEW BASE BOARD AND MOULDING.
2. BASEBOARD AND MOULDING NOT REQUIRED FOR FLOORING ADJOINING MILLWORK. INSTALL
TOE KICKS FOR ALL NEW CABINETRY/DRAWERS.
3. PLANK PATTERN SHALL BE OFFSET, EAST-WEST (OFFSET BY HALF THE WIDTH OF THE PLANK).
4. FOR BASEBOARD/MOULDING APPLICATIONS IN BATHROOMS, PLACE WATER-PROOF CAULK
BEHIND TO PREVENT WATER FROM PENETRATING.
5. FOR INSIDE AND OUTSIDE CORNER MOULDING APPLICATION, USE MILTER JOINTS (CUT AT 45
DEGREE ANGLE).
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
6/8 /20
:1
4 R
IC
HA
RD
RP
OL
AN
CO
C :\U
SE
RS
\R
IC
HA
RD
RP
OL
AN
CO
\D
ES
KT
OP
\R P\
PR
OJ
EC
TS
\Y
AQ
UI
H
OU
SE
R
EN
OV
AT
IO
N
AN
D
FL
OO
RI
NG
\1_
PR
E-
SO
LI
CI
TA
TI
ON
\D
RA
W
IN
GS
\E
XH
IB
IT
XX
_D
RA
W
IN
GS
.D W
G;
R3
SOUTHWESTERN REGION
SOUTH YAQUI HOUSE
REMODEL
APACHE-SITGREAVES
NATIONAL FORESTS
SPRINGERVILLE RANGER
DISTRICT
FINISH AND LIGHTING
SCHEDULE
06/08/2020
R.POLANCO
R.POLANCO
C.MILLER
A-08
018013
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
6/8 /20
:1
4 R
IC
HA
RD
RP
OL
AN
CO
C :\U
SE
RS
\R
IC
HA
RD
RP
OL
AN
CO
\D
ES
KT
OP
\R P\
PR
OJ
EC
TS
\Y
AQ
UI
H
OU
SE
R
EN
OV
AT
IO
N
AN
D
FL
OO
RI
NG
\1_
PR
E-
SO
LI
CI
TA
TI
ON
\D
RA
W
IN
GS
\E
XH
IB
IT
XX
_D
RA
W
IN
GS
.D W
G;
R3
SOUTHWESTERN REGION
SOUTH YAQUI HOUSE
REMODEL
APACHE-SITGREAVES
NATIONAL FORESTS
SPRINGERVILLE RANGER
DISTRICT
HARDWARE, DECOR,
AND EQUIPMENT
SCHEDULE
06/08/2020
R.POLANCO
R.POLANCO
C.MILLER
A-09
018014
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
6/8 /20
:1
4 R
IC
HA
RD
RP
OL
AN
CO
C :\U
SE
RS
\R
IC
HA
RD
RP
OL
AN
CO
\D
ES
KT
OP
\R P\
PR
OJ
EC
TS
\Y
AQ
UI
H
OU
SE
R
EN
OV
AT
IO
N
AN
D
FL
OO
RI
NG
\1_
PR
E-
SO
LI
CI
TA
TI
ON
\D
RA
W
IN
GS
\E
XH
IB
IT
XX
_D
RA
W
IN
GS
.D W
G;
R3
SOUTHWESTERN REGION
SOUTH YAQUI HOUSE
REMODEL
APACHE-SITGREAVES
NATIONAL FORESTS
SPRINGERVILLE RANGER
DISTRICT
HARDWARE, DECOR,
AND EQUIPMENT
SCHEDULE (CONT'D)
06/08/2020
R.POLANCO
R.POLANCO
C.MILLER
A-10
018015
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
6/8 /20
:1
4 R
IC
HA
RD
RP
OL
AN
CO
C :\U
SE
RS
\R
IC
HA
RD
RP
OL
AN
CO
\D
ES
KT
OP
\R P\
PR
OJ
EC
TS
\Y
AQ
UI
H
OU
SE
R
EN
OV
AT
IO
N
AN
D
FL
OO
RI
NG
\1_
PR
E-
SO
LI
CI
TA
TI
ON
\D
RA
W
IN
GS
\E
XH
IB
IT
XX
_D
RA
W
IN
GS
.D W
G;
R3
SOUTHWESTERN REGION
SOUTH YAQUI HOUSE
REMODEL
APACHE-SITGREAVES
NATIONAL FORESTS
SPRINGERVILLE RANGER
DISTRICT
DOOR SCHEDULE
06/08/2020
R.POLANCO
R.POLANCO
C.MILLER
A-11
018016
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
6/8 /20
:1
4 R
IC
HA
RD
RP
OL
AN
CO
C :\U
SE
RS
\R
IC
HA
RD
RP
OL
AN
CO
\D
ES
KT
OP
\R P\
PR
OJ
EC
TS
\Y
AQ
UI
H
OU
SE
R
EN
OV
AT
IO
N
AN
D
FL
OO
RI
NG
\1_
PR
E-
SO
LI
CI
TA
TI
ON
\D
RA
W
IN
GS
\E
XH
IB
IT
XX
_D
RA
W
IN
GS
.D W
G;
R3
SOUTHWESTERN REGION
SOUTH YAQUI HOUSE
REMODEL
APACHE-SITGREAVES
NATIONAL FORESTS
SPRINGERVILLE RANGER
DISTRICT
CONSTRUCTION
DETAILS
06/08/2020
R.POLANCO
R.POLANCO
C.MILLER
A-12
018017
HOLLOW CORE COMPOSITE INTERIOR DOOR
NO SCALE
ELEVATION VIEWDETAIL 1A
6'-8"
SEE DOOR SCHEDULE
FOR HARDWARE
42"
4" X 4" STANDARD
HINGES (TYP.); SATIN-
CHROME FINISH; SIZED
AND GAUGED FOR
DOOR WEIGHT
42"
FOR ALL NEW DOORS, INSTALL ALL
REQUIRED TO MAKE DOOR FULLY
FUNCTIONAL, INCLUDING NEW DOOR
STRIKES, HINGES, ETC. ALL
MISCELLANEOUS HARDWARE SHALL BE
SATIN-CHROME FINISH.
PAINT DOORS AND WOOD BASE (WHITE)
TO MATCH BASEBOARD/MOULDING.
PROVIDE NEW WOOD TRIM AT NEW
LOCATIONS.
ROOMS E / F / G: KEYED INDIVIDUALLY
ROOM H: INSTALL PRE-HUNG ASSEMBLY.
DOOR; REFER
TO SCHEDULE WOOD FRAME
FRAME ANCHOR;
PROVIDE THREE (3)
PER JAMB MIN.
PAIR WOOD STUDS;
SECURED TOGETHER
AT 16" O.C. VERTICAL
(TYP.)
SEALANT BOTH SIDES
AT FRAME
1/2" BOARD
W/ METAL
EDGE
2"
2"
2"
2"
9/16" X 3-1/4" WOOD BASE
(TYP. BOTH SIDES)
DETAIL 3A CROSS SECTION
INTERIOR DOOR JAMB
NO SCALE
DETAIL 4A CROSS SECTION
INTERIOR DOOR HEADER
NO SCALE
1/2" BOARD (SEE
FINISH SCHEDULE
FOR TYPE)
2" 2" 2"
2"
WOOD FRAME
TWO (2) 2X8 STUD RUNNERS
SECURED TO DOUBLE STUD
AT EACH END. CONTINUOUS
SEALANT BOTH SIDES
AT FRAME (TYP.)
CEILING (HEIGHT
VARIES)
9/16" X 3-1/4" WOOD
BASE (TYP. BOTH
SIDES)
DOOR; REFER
TO SCHEDULE
DETAIL 2A CROSS SECTION
ACCESSIBLE SINK/CABINET
SCALE: 1" = 1'
9"9"
2'-3"
4"
4"
9" 3"
1'-9"
FLAT PANELS SAME
FINISH/COLOR AS CABINETRY
(NO PRAIRIE STYLE REQUIRED)
DETAIL 5A PLAN VIEW
NEW WALL TYPICAL
NO SCALE
1/2" BOARD (TYP.); SEE
WALL SHEET NOTES FOR
SPECIFIC MATERIAL
REQUIREMENTS
SOUND ATTENUATING
INSULATION
2X4 WOOD STUDS
AT 16" O.C.
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
LIGHTING LEGEND
VANITY LIGHT FIXTURE
HUNTER CHANNING CEILING/LIGHT
HUNTER DONEGAN CEILING/LIGHT
HALO LED TILTABLE
VENT/LIGHT COMBOVL
VL
VL
EXTERIOR LIGHT (INSTALL…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .