RFIs_&_responses.pdf

PDF 2 MB Posted

Attached to
Upgrade the Containment Lab, Otis PSDEL Federal contract opportunity
Solicitation number
12639518R0035
Issued by
Department of Agriculture Animal and Plant Health Inspection Service Headquarters

View the file

Other files for this federal contract opportunity

Other files attached to Upgrade the Containment Lab, Otis PSDEL, newest first.
File Type Posted
12639518R0035-0005.pdf PDF
RFIs_&_responses.pdf PDF
General_Decision_Number_MA1.pdf PDF
12639518R0035-0004.pdf PDF
RFI_01_Controlled_Environment_Rooms.docx DOCX document
12639518R0035-0003.pdf PDF
General_Decision_Number_MA1.pdf PDF
12639518R0035-0002.pdf PDF
12639518R0035-0001.pdf PDF
General_Decision_Number_MA1.pdf PDF
12639518R0035.pdf PDF
General_Decision_Number_MA1.pdf PDF
APHIS_PSEL_Phase_3_-_Final_Submittal_Specifications.pdf PDF
Phase_3_Drawings_Issued_for_Construction_4-20-18.pdf PDF
Show all 14

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Solicitation 12639518R0035 RFIs and Responses

1. Is a standard galvanized interior casing sufficient, or does it need to be aluminum or stainless? Exhaust air ductwork from the two fume hoods shall be stainless steel fully welded.

Galvanized steel ductwork from rest of the building is acceptable.

2. Do the coils, fans, dampers, or aluminum plate HX need to have any type of coating? No

3. Is there any concern with hazardous conditions in the EA to require explosion proof motors? No

4. Is any special filtration needed, beyond standard 2” MERV 8 filters, before the high plume nozzle discharge of the unit? MERV 8 filter in exhaust airstream is sufficient. MERV 14 in addition to MERV 8 filters are required in the supply airstream.

5. Do you need any special airflow monitoring anywhere in the unit? Airflow measurement stations are required for both supply and exhaust airstreams. See sheet M-701.

6. Will you need a bleed air inlet damper, in case of variable air volume from the lab space, to maintain a constant air flow discharge from the unit? The high plume exhaust fan’s windband takes air from ambient and mixes it with exhaust from exhaust air from the building to maintain constant discharge airflow. No additional bleed air damper is required.

7. On Drawing A-110, there is an equipment schedule for Lab equipment to be CFCI. However, nowhere in the specs or the drawings show the individual specifications for the equipment to be supplied. Can the Government please confirm the individual specifications, as well as any options for each piece of Lab equipment to be supplied and installed by the Contractor?

The equipment listed on Sheet A110 are the two fume hoods and the two autoclaves. Both items are covered in Division 11.

8. Project specification contain Section 26 41 00 Lightning Protection System. However, on the project plans there is no referenced to lightning Protection. Is lightning protection required and if so what is the scope of work? The Lightning Protection specification was included as part of the project specifications that included all three phases. However, it only applies to Bldg 1365 as part of Phase 2 and is not applicable for Bldg 1398 – Phase 3.

9. What/Who is the Basis of Design for AHU-2? Trane.

10. What/Who is the Basis of Design for the Re-Heat Coils? Trane.

11. EL103 shows light fixtures that appear to be 1x4 but doesn't call out a "Type" of fixture.

Keynote #1 leads me to believe these are new and not existing. See approved submittal from a previous project below.

12. The general notes on ES101 state we are to bring CAT6 drops back room 12A (Phase B). Some of these drops are 300+ ft away which could run us into some problems. Cat 6 caps out at 300' of total distance before it will not work anymore. The drops in the CER rooms aren't being touched by us so those don't matter, but there are several others that do.

The final routing of Cat6 horizontal cables shall be field coordinated to maintain lengths less than 295ft. Where field conditions do permit lengths less than 295ft, provide an Ethernet extender above ceiling to extend Cat6 cabling to outlet locations. Provide 120V receptacles as required for power connection to repeaters.

SUBMITTED FOR:

P&S Construction, Inc.

PROJECT:

TO:

ATTN:

Shop Drawings Approval Approved as Submitted

WE ARE SENDING:

Letter Your Use Approved as Noted Prints As Requested Returned After Loan Change Order Review and Comment Resubmit Plans Submit Samples Returned Specifications Returned for Corrections

Other: Made from Submittal

SENT VIA:

Attached

Separate Cover Via: Mail

DATE:

REF:

Life Safety & HVAC Improvement

STV Corporation 205 West Welsh Dr.

Douglassville, PA 19518-8713

Lalonnie Pufnock

11 School Street North Chelmsfor, MA 01863

Due Date:

TRANSMITTAL

No. 00110

8/15/2011

Interior Luminaires

ACTION TAKEN:

Phone: 978-452-3782

ITEM PACKAGE SUBMITTAL DRAWING REV. ITEM NO. COPIES DATE DESCRIPTION STATUS

NEWTitle: Product Data Desc: Part 2

8/15/2011100116510-0116510SUB

NEWTitle: Shop Drawings Desc: Par. 1.3.B

8/15/2011100116510-0216510SUB

Remarks:

CC: Signed:

Rex Radloff

Expedition

9- L

S -E

A

14689-LS-E0014A

X

John Hopkins 8/17/11

Project Information

Job Name: Submit to: P & S Construction Inc.

Pest Survey Detection and Exclusion Lab 11 School Street

N. Chelmsford, MA 01863

Architect: Engineer:

Project Submittal No: Date: Revision: 0

Item Information

Item Description:

Drawing Reference:

Spec Reference: Section 16510 Par. All Page

Yes No X

X X X X

Additional Notes:

Response

8/15/201114

Req's other trade coordination?

Additional action required?

Question Complies with contract docs?

Alternate manufacturer?

Camp Edwards, MA

STV Incorporated

Cost impact?

Lighting

205 West Welsh Drive Douglassville, PA 19518

Life Safety/HVAC Improvements

Submittal Cover Sheet

37 Fairbanks Court Douglas, MA 01516

Phone: 508-476-0096 Fax: 508-476-9027

OTIS AFB BLDG 1398

SCHEDULE Date: 08-10-2011 Page 1

Type Mfg Description

A COOPER CC7NCSDSM

B COOPER LPXH70RWHSD

C COOPER 12XW9DWMHWH

D COOPER 2AC2-232BI-UNV-LL835-EB81-U

E COOPER WN-232A-UNV-EB81-U

DNL COOPER IST-100-HPS-MT-2S-BK-L

LCP COOPER CONTRL LK8

LCP COOPER CONTRL LRC

2AC2-232BI-UNV-L8835-EB81-U

Submitting Agency: Description: CC7NCSD Project: OTIS AFB BLDG 1398 Notes:

Type:

A

Catalog #

Project

Comments

Prepared by

Type

Date

SPECIFICATION FEATURES

03/19/2008 11:45:05 AMConsult your representative for additional options and finishes.

Specifications and Dimensions subject to change without notice. ADX041145

DESCRIPTION

The CC7 Contractor's Choice FasTest(TM) High Capacity Emergency

Lighting Units are an affordable, attractive alternative to standard white two-headed emergency lighting units. All components snap together to facilitate installation in 5 minutes or less. Field versatility is not sacrificed for cost, both lighting heads offer full horizontal and vertical adjustability. More-over, proper operation of the transfer circuit and emergency lamps can be quickly and safely verified by using a convenient laser pointer (accessory).

In addition, Watchguard EMS self-diagnostic system is standard (CC7NCSD only). The CC7 FasTest(TM) is ideal for applications demanding minimum cost but maximum flexibility, reliability, convenience and aesthetics.

Electronic

- Dual-Voltage Input 120/277 VAC, 60 Hz

- Line-Latching

- Solid-State Voltage

Limited Charger

- Solid-State Switching

- Low-Voltage Disconnect

- Brownout Circuit

- Overload/Short Circuit Protection

- Push-Button Test Switch/Power

Indicator Light

- Remote Photocell Test Switch*

(requires accessory laser for activation)

- Automatic 30-Sec. Test

Upon Switch Activation

- Push-In AC Power Connectors

Facilitate Installation

Housing Construction

- Snap-Fit Component Design

Facilitates Under-5-Minute

Installation

- Reinforcing Ribs Throughout to

Provide Maximum Strength

- Injection-Molded, Color-Stable, High-Impact UL 94-5V Rated

Polycarbonate Housing and

Mounting Plate

- Watchguard EMS self-diagnostic system

(CC7NCSD only)

- Designer-White Textured Finish

- Knockouts/Cutouts Provided in

Housing for Surface Conduit

Attachment

- Universal J-Box

Mounting Pattern

- Keyhole Mounting Slots

Battery

- Sealed Lead Calcium, Recombination

- Nickel Cadmium Battery

(CC7NCSD)

- Maintenance-Free, Long-Life

- Full Recharge Time, 24 hrs. (max.)

- Polarized Battery Terminals

Code Compliance

- UL 924 Listed

- Life Safety NFPA 101

- CSA Certified

- NEC/OSHA

- Most State and Local Codes

Warranty

- Unit: 1-year

- Battery: 5-year Pro-Rata

- Nickel Cadmium Battery: 15-year

Pro-Rata

Head/Lamp Data

- Two 12W, 12V Heads Standard

- New Head Design Accepts

Almost Any Lamp

- Glare-Free Lens

- Fully Adjustable Lamp

Housing

- High-Impact Polycarbonate

- Matches Housing Finish

- Remote Capability, Standard: 36W Lead Calcium

26W Nickel Cadmium

- Housing Has (8) Locations for

Mounting of Heads; Consult

Factory (3 optional bottom-mount and 3 optional top-mount locations)

- Optional square and MR16 heads available

* Minor position adjustment of photocell sensor may be required if mounted in locations with high ambient light.

CC7

SERIES

ORDERING INFORMATION

Accessories 6

Mounting Kit

2MSWH Mounting Shelf=

Protective Housing

WG3 Wire Guard=

VS1 Polycarbonate Vandal Shield=

VS1WP Weather Resistant Vandal Shield=

LASER Key Chain, Red Laser Pointer (activation tested at 30 feet).=

Options 1, 2, 3

MRT MR16 Lamp Heads4=

SQ Square Heads4=

V Voltmeter=

SD Self Diagnostics5=

TDM Time Delay Monitor=

SM Side Mount Lamps=

TM Top Mount Lamps=

BM Bottom Mount Lamps=

Series

CC7

CC7NC

SEALED LEAD

CALCIUM BATTERY

NICKEL BATTERY

FasTest Emergency

Lighting Unit

Emergency Lighting

Notes: 1 Add as a suffix. 2 Consult your Cooper Lighting Representative for alternate lamps and additional options. 3 Alternate Lamps, Head Types, No Head, Multiple

Heads and other options. Consult your Cooper Lighting Representative. 4 12W lamp standard. 5 CC7NC Only. 6 Order separately.

13” [330mm]

4 7/8” [124mm]

5 3/4” [146mm]

7 15/16” MAX

[202mm]

19 1/4” MAX [489mm]

Verify proper operation of the transfer circuit and emergency lamps with convenient laser pointer (sold as an accessory).

COOPER LIGHTING - SURE-LITES®

CC7NC SD SM

CC7NCSDSM

Notes:

Type:

A

Sure-Lites • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 03/19/2008 11:45:05 AM Specifications and Dimensions subject to change without notice. ADX041145

ELECTRICAL RATINGS

ENERGY DATA

PHOTOMETRICS

SERIESCC7

Model DC Voltage1 1/2 Hours 4 Hours

CC7 12 60 25

CC7MRT 12 60 25

CC7NCSD 12 50 26

Rated Wat tag e to 87 1/2% of Rated D.C. Voltage Lamp In f o rmat io n

Type Wattage Number Spacing

Incandescent 12W ea 029-132 24' MR16 12W ea 029-141 50' Incandescent 12W ea 029-132 24'

Charge Mode (Fully Discharged Battery)

Lead Calcium Nickel Cadmium Input Power: Input Power:

120V=28W 120V=12W 277V=28W 277V=11W

Input Current Input Current (Max.): (Max.):

120V=.26A 120V=.12A 277V=.11A 277V=.05A

Power Factor: Power Factor:

120V=>.91 120V=>.87 277V=>.91 277V=>.87

T.H.D.: T.H.D.:

120V=<35% 120V=<42% 277V=<39% 277V=<45%

Standby Mode (Fully Charged Battery)

Lead Calcium Nickel Cadmium Input Power: Input Power:

120V=3.8W 120V=7.8W 277V=3.7W 277V=7.1W

Input Current Input Current (Max.): (Max.):

120V=.07A 120V=.08A 277V=.03A 277V=.04A

Power Factor: Power Factor:

120V=>.50 120V=>.77 277V=>.50 277V=>.77

T.H.D.: T.H.D.:

120V=<94% 120V=<53% 277V=<99% 277V=<58%

029-132 24' Spacing Illuminance Values(Fc) Average=3.09 Maximum =14.6 Minimum =0.4

Avg/Min Ratio=7.73 Max/Min Ratio=8.33 Max/Min Ratio=36.50

For Standard Fixture: CC7***

029-141 50' Spacing Illuminance Values(Fc) Average=0.84 Maximum =5.8 Minimum =0.1

Avg/Min Ratio=8.40 Max/Min Ratio=58.00

For Standard Fixture: CC7MRT***

***The "Rule of Thumb" spacing guidelines are designed to achieve 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum/minimum ratio. The corridor used is 100 feet long, 9 feet ceiling with a 6 feet wide walkway and 3 feet path of egress. The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is 7.0 feet with a lamp head angle of 45 degrees.

Cooper Lighting assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code compliance.

Notes:

Type:

A

Sure-Lites • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 03/19/2008 11:45:05 AM Specifications and Dimensions subject to change without notice. ADX041145

TECHNICAL DATA

Lam ps

Designed specifically for emergency lighting applications, the PAR 36 12V sealed-beam type design insures optimum glare-free trapezoidal light distribution along with horizontal and vertical adjustment by rotating the lens within the housing.

H ous i ng

The subtly detailed Model CC-7 housing is constructed of flame-retardant and impact-resistant polycarbonate in a color-stable designer-white finish. All electrical components are securely attached in the housing and prewired for fast AC connection. The housing snaps on to the hinged mounting plate with two integral locking tabs. The mounting plate has keyhole mounting slots and a universal mounting pattern for quick, efficient installation. The housing contains knockouts/cutouts for surface conduit attachment. All structural components are designed with reinforcing ribs to add additional rigidity and to maximize structural integrity.

L i ne -La tch ed

Sure-Lites’ line-latched electronic circuitry makes installation easy and economical. A labor efficient AC-activated load switch prevents the lamps from turning on during installation to a non-energized AC circuit. Line-latching eliminates the need for a contractor’s return to a job site to connect the batteries when the building’s main power is permanently turned on.

So l i d -Sta te Charg er

Supplied with a 120/277 VAC, voltage regulated solid-state charger. Immediately upon restoration of AC current after a power failure, the charger provides a high charge rate. The charge circuit reacts to the condition of the battery and alters the rate of charge in order to maintain peak battery capacity and maximize battery life. Solid-state construction recharges the battery following a power failure in accordance with

UL 924.

O ver l o ad an d Sh o rt C i r cu i t P ro tec t i on

The solid-state overload monitoring device in the DC circuit disconnects the lamp load from the battery should excessive wattage demands be made and automatically resets when the overload or short circuit is removed. This overload current protective feature eliminates the need for fuses or circuit breakers for the DC load.

Brow n o u t C i r cu i t

The brownout circuit in Sure-Lites units monitors the flow of AC current to the unit and activates the emergency lighting system when a predetermined reduction of AC power occurs. This dip in voltage will cause most ballasted fixtures to extinguish causing loss of normal lighting even though a total power failure has not occurred.

So l i d -Sta te Trans fer

The unit incorporates a solid-state switching transistor which eliminates corroded and pitted contacts or mechanical failures associated with relays. The switching circuit is designed to detect a loss of AC voltage and automatically energizes the lamps.

Upon restoration of the AC power, the emergency lamps will switch off and the charger will automatically recharge the battery.

Low -Vo l tage D i sconne c t

When the battery’s terminal voltage falls below 80% of the rated voltage, the low-voltage circuitry disconnects the lighting load. The disconnect remains in effect until normal utility power is restored, preventing deep battery discharge.

Test Sw i tch/Pow er I nd i ca to r L i g h t

Conveniently located combination Test Switch/Power Indicator Light allows for manual verification of proper operation of the transfer circuit and emergency lamps. The emergency lamps will test for 30 seconds when activated.

Photoce l l Tes t Sw i tch

Allows verification of proper operation of the transfer circuit and emergency lamps with a laser pointer (laser is sold as an accessory). The emergency lamps will test for 30 seconds when activated.*

Sea l ed Lead -Ca l c i um Bat te ry

The fully sealed, long-life, maintenance-free, lead-calcium battery is ideal for emergency lighting applications. These recombinant cycle batteries typically provide eight to ten years of life and may be operated in any position.

Sea l ed N i cke l Cad mi u m Bat te ry

Sure-Lites sealed nickel cadmium batteries are maintenance-free with a life expectancy of 15 years. The sealed rechargeable nickel cadmium battery utilizes positive and negative sintered plate construction which offers high discharge rates and stable performance over a wide range of temperatures. The specially designed resealable vent automatically controls cell pressure, assuring safety and reliability. This battery is best suited for harsh ambient temperatures because the electrolyte is not active in the electrochemical process. The nickel cadmium battery can be operated from 0°C to 50°C.

Warran ty

All Sure-Lites units are backed by a firm one-year warranty against defect in material and workmanship (excluding lamps). Maintenance-free, long-life, sealed lead calcium batteries carry a five-year Pro-Rata warranty.

* Minor position adjustment of photocell sensor may be required if mounted in locations with high ambient light.

Submitting Agency: Description: LPXH70RWH

Notes:

Type:

B

Catalog #

Project

Comments

Prepared by

Type

Date

Specifications and dimensions subject to change without notice.

Consult your representative for additional options and finishes.

COOPER LIGHTING - SURE-LITES®

The LPX Series LED Exit is an economical, yet attractive, alternative to metal exits. Its contemporary round corner styling, designer white finish, and consistent family appearance enables it to blend with any decor. The tough injection molded polycarbonate materials resist discoloration. All components, including canopy and chevron directional indicators, are of snap-fit construction to facilitate installation. The under 5-minute installation time of the LPX Series Exit makes it the fastest installed exit on the market today. All LPX Series Exits are available in universal configurations.

SPECIFICATION FEATURES

Electrical

- Dual Voltage Input 120/277 VAC, 60Hz, Isolation Transformer

- Line-latching

- Solid-state Voltage Limited

Charger

- Solid-state Switching

- Brownout Circuit

- Low-Voltage Disconnect

- Overload/Short-Circuit

Protection

- Test Switch/Power Indicator

Light

- Push-in AC power connectors facilitate installation

Housing Construct ion

- All components are injection-molded, color stable, high impact

UL 945VA rated polycarbonate material

- Designer white textured finish standard

- Components are of snap-fit construction to facilitate under 5-minute installation

- Reinforcing ribs throughout to provide maximum strength

- Molded-in wireways facilitate internal wire routing and connections

- All components including battery and electronics are located inside the exit housing

- Snap-out or snap-in chevron directional indicators have full 3/4" stroke

- Knockout provided on housing for surface conduit attachment

- Universal exits can be field configured as single or double face

- Snap-fit canopy with captive mounting screws included with all exits

- Exit can be ceiling, wall, or end mounted

- Universal J-box mounting pattern

- Accepts up to four (4)

LPX1HWH heads

Battery

- Sealed Lead Calcium

- Maintenance-Free, Long-Life

- Full Recharge Time, 48 hours

(max.)

Code Compliance

- UL 924 Listed

- Damp Location Listed

- UL 924, 4 hour rated

- Life Safety NFPA 101

- NEC/OSHA

- Most State and Local Codes

Lamp Data

- AC LED: Long life LED lamps provide uniform diffused illumination

- DC LED: DC lamps (Brighter in emergency mode)

Warranty

- Exit: 1-Year

- Battery: 5-year pro-rata

(Lead Calcium)

LPXH

SERIES

DESCRIPTION

POLYCARBONATE EXIT

SELF-POWERED

EMERGENCY WITH

HIGH POWER

(REMOTE CAPACITY)

LED LAMPS

EXIT LIGHTING

ADX040876 pc

2011-07-06 15:20:20

E N E R G Y

DATA

Maximum power consumption under all charge conditions:

Standby Mode

(Fully charged

Battery):

Sealed Lead

Calcium Battery

LED Exits - Red

Input Power:

120V = 4.9W

277V = 4.7W

Input Current (Max.):

120V = .07A

277V = .03A

Power Factor:

120V = >.59

277V = >.64

T.H.D.:

120V = <45%

277V = <44%

LED Exits -

Premium Deep

Green

Input Power:

120V = 3.1W

277V = 2.9W

Input Current (Max.):

120V = .06A

277V = .02A

Power Factor:

120V = >.41

277V = >.44

T.H.D.:

120V = <49%

277V = <53%

Charge Mode

(Discharged

Battery):

Sealed Lead

Calcium Battery

Input Power consumption is increased by approximately 2.7 watts in the charge operating mode for red units and 3.2 watts for green units.

2011-07-08 09:07:15

ORDERING INFORMATION

Letter Colors

R Red=

G Green=

DG Premium Deep Green

Accessories 1

Protective Housing

WG10 Surface Mount Wire Guard (Wall Mount Only)=

WGS11 Ceiling or End Mount Wire Guard (Ceiling or End Mount Only)

WG12 Wire Guard,Ceiling or Wall Mount=

WG17 Ceiling or Wall Mount (with heads)=

VS1 Polycarbonate Vandal Shield=

VS1WP Weather Resistant Vandal Shield (Wall Mount Only)

VS2 Polycarbonate Vandal Shield=

VS2WP Polycarbonate Vandal Shield - Weather Proof=

Pendant Kit

CCX18PKWH 18" Pendant Kit, White=

CCX18PKHTWH 18" Hang True Pendant Kit, White=

LPXIHWH Head Assembly=

Voltage

__ 120/277VAC=

Series

LPXH7 Polycarbonate Exit-High Power (Remote Capacity)

Heads

__ No Heads=

DH Double Heads= Face Options

0 Universal= Housing Finish

WH White=

BK Black=

Options

SD Self Diagnostics

Battery

__ Lead Calcium=

__ Nickel Cadmium

1 Order separately.Notes:

LPXH7 0 R WH SD

LPXH70RWHSD

Submitting Agency: Description: LPXH70RWH

Notes:

Type:

B

Specifications and dimensions subject to change without notice.

Sure-Lites • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

LPXH SERIES - SELF-POWERED

TECHNICAL DATA

Lamps

The LPXH Series Exits use energy efficient, long-life LED’s to provide uniform diffuse illumination of the exit face. The low operating costs and zero maintenance requirement makes

LED lamps the wisest choice for exit signs today. Emergency exit illumination is provided by LED lamps.

Housing Construct ion

Rugged, durable, injection molded polycarbonate materials are used throughout the LPXH Series Exits. All structural components are designed with reinforcing ribs to add additional rigidity and to maximize structural integrity. These materials are impact and scratch resistant, and they have been UV stabilized to resist discoloration due to age and ultraviolet radiation. All components are designed to be of snap-fit construction - no mechanical fasteners -to facilitate installation in under 5-minutes. Any components required for installation (wirenuts, wire leads, universal metal J-box bracket, etc.)

are all included with each exit. The universal design of the LPXH Series Exits enables universal exits to be configured as single or double face in the field. The LPXH Series Exits can be wall, ceiling, or end mounted; a rugged, snap-fit, low profile canopy with captive screws is included with every exit for ceiling and end mounting applications.

Lens

Lenses for the LPXH Series Exits are made from durable, impact resistant polycarbonate. All exit faces are designed with full 3/4” stroke snap-out or snap-in chevron directional indicators to insure maximum visibility and compliance with the latest codes.

Line-Latched

Sure Lites’ line-latched electronic circuitry makes installation easy and economical. A labor efficient AC activated load switch prevents the lamps from turning on during installation to a non-energized AC circuit. Line-latching eliminates the need for a contractor’s return to a job site to connect the batteries when the building’s main power is turned on.

Sol id-State Charger

Supplied with a 120/277 VAC, voltage regulated, solid-state charger. Immediately upon restoration of AC current after a power failure, the charger provides a high charge rate. The charge circuit reacts to the condition of the battery and regulates the charging process in order to maintain peak battery capacity and maximize battery life. Solid-state construction recharges the battery following a power failure in accordance with UL 924.

Brownout Circuit

The brownout circuit on Sure- Lites’ exits monitors the flow of AC current to the exit and activates the emergency lighting system when a predetermined reduction of AC power occurs.

This dip in voltage will cause most ballasted fixtures to extinguish causing loss of normal lighting even though a total power failure has not occurred.

Sol id-State Transfer

The LPXH Series Exits incorporates solid-state switching which eliminates corroded and pitted contacts or mechanical failures associated with relays. The switching circuit is designed to detect a loss of AC voltage and automatically energizes the lamps using DC power. Upon restoration of AC power, the DC power will be disconnected and the charger will automatically recharge the battery.

Low-Voltage Disconnect

When the battery’s terminal voltage falls, the low-voltage circuitry disconnects the lighting load. The disconnect remains in effect until normal utility power is restored, preventing deep battery discharge.

Test Switch/Power Indicator L ight

A test switch located on the side of the exit permits the activation of the emergency circuit for a complete operational systems check. The

Power Indicator Light provides visual assurance that the AC power is on.

Overload and Short Circuit Protect ion

The solid-state overload monitoring device in the DC circuit disconnects the lamp load from the battery should excessive wattage demands be made and automatically resets when the overload or short circuit is removed. This overload current protective feature eliminates the need for fuses or circuit breakers for the DC load.

Sealed Lead Calc ium Battery

The fully sealed, long-life, maintenance-free lead calcium battery is ideal for emergency lighting applications. These recombinant cycle batteries typically provide 8 to 10 years of life and may be operated in any position.

Warranty

All Sure-Lites’ products are backed by a firm one-year warranty against defects in material and workmanship. Maintenance-free, long-life, sealed lead calcium batteries carry a five-year pro-rata warranty.

WATTAGE RATINGS

ADX040876 pc

2011-07-06 15:20:20

2011-07-08 09:07:15

LPXH70RWHSD

Submitting Agency: Description: 12X9DWMHWH

Notes:

Type:

C

Catalog #

Project

Comments

Prepared by

Type

Date

Specifications and dimensions subject to change without notice.

Consult your representative for additional options and finishes.

COOPER LIGHTING - SURE-LITES®

Designed to perform in wet locations. Lamp housing is made of corrosion resistant 22 gauge die formed spun aluminum with a powder coat finish and a die cast aluminum, gasketed mounting plate. Sealed swivel and coated lamp terminals resist oil, water and dust. Available in standard industrial white finish-specify color when ordering; other finishes available. Heads adjust 80° from vertical with 358° rotation.

Supplied complete with a 5" diameter die cast, grey finished, gasketed mounting plate. UL 924 Listed, CSA Certified. City of Chicago Code (see catalog numbers with *), UL Wet Location Listed.

SPECIFICATION FEATURES

Electrical

- 6V DC and 12V DC

- Input Voltage

Lampholder/Mounting Plate

Construct ion

- Lamp housing is made of corrosion resistant, 22-gauge die formed spun aluminium with a polyester powder coat paint finish

- Die cast, gasketed mounting plate

- Die cast aluminum swivel assembly allows 80° adjustment from vertical with

358° rotation

- Sealed swivel and coated lamp terminals resist oil, water, and dust

- Available in standard industrial white finish

- specify color when ordering other finishes

- Finish code suffix must be added to catalog number to designate color

- Supplied complete with 5" diameter die cast, grey finished, gasketed mounting plate

- Designed to perform in wet environments

- Use WG-8 Wire Guard for single head remotes; use

WG-9 Wire Guard for double head remotes

Code Compliance

- UL 924 Listed

- UL Wet Location Listed

- City of Chicago Code

(see catalog numbers with *)

Warranty

- Unit: 1-year

Lamp Data

- 6 and 12 Volt Halogen Sealed

Beam

- 6 and 12 Volt Incandescent

Sealed Beam

- 6 and 12 Volt Wedge Base

Incandescent Sealed Beam

- Features a wedge base lamp incorporated into a unique sealed beam unit

- Consult factory for other lamp types (See Technical

Information Section)

6 AND 12 VOLT

WEATHERPROOF

METAL HEAD

DESCRIPTION

Wedge Base SB is Wedge Base Seal Beam WH - White (standard finish) GY - Grey BK - Black

* Meets City of Chicago Code

NOTES

ADX041229 pc

2011-07-12 10:47:28

E N E R G Y DATA

Power Consumption is equal to lamp wattage.

SINGLE AND DOUBLE

HEAD REMOTES

EMERGENCY LIGHTING

2011-07-12 11:07:11

ORDERING INFORMATION

Sample Number: 6X9DWM/HWH

Remote Heads

__ Single Remote Head

D Double Remote Heads

Series

WMH

Accessories 1

Protective Housing

WG8 Wire Guard for Single Head=

WG9 Wire Guard for Double Heads=

Voltage

6 6 Volt=

12 12 Volt=

Lamp Type

T Halogen=

X Incandescent=

Wattage

54 5.4 W=

6 6 W=

7 7.2 W=

8 8 W=

9 9 W=

10 10W=

12 12 W=

18 18W=

20 20 W=

25 25 W=

30 30W=

37 37.5W=

50 50 W=

Housing Finish

WH

BK

GY

Notes: 1 Order separately. * Alternate Lamps, Finishes and Options available. Consult your Cooper Lighting Representative.

12 X 9 D WMH WH

Submitting Agency: Description: 12X9DWMHWH

Notes:

Type:

C

Specifications and dimensions subject to change without notice.

Sure-Lites • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

6.

O

N M

A R

G

AI

D n oit u birt si D l at n o zir o

H n oit u birt si

D l a citr e V

88-92,57-92.

O

N P

M

AL

2.

O

N M

A R

G

AI

D

51 T E

EF

TF

EL

T E

EF

T

H

GI

R

)sixa n o der usae M(

P M

AL

M

O

RF

T E

EF

1.0 2.0

3.0 5.0

CF1

P M

AL

SI

X A

51 T E

EF

TF

EL

T E

EF

T

H

GI

R

)sixa n o der usae M(

P M

AL

M

O

RF

T E

EF

P

M

AL

SI

X

A 1.0

2.0 3.0

5.0

CF1

3.

O

N M

A R

G

AI

D

4.

O

N M

A R

G

AI

D

5.

O

N M

A R

G

AI

D

7.

O

N M

A R

G

AI

D

8.

O

N M

A R

G

AI

D

9.

O

N M

A R

G

AI

D

01.

O

N M

A R

G

AI

D

11.

O

N M

A R

G

AI

D

21.

O

N M

A R

G

AI

D n oit u birt si D l at n o zir o

H n oit u birt si

D l a citr e V

PHOTOMETRICS 6 AND 12 VOLT WEATHERPROOF METAL HEAD

ADX041229 pc

2011-07-12 10:47:28

2011-07-12 11:07:11

Submitting Agency: Description: 2AC2-232BI-UNV-L8835-EB81-U

Notes:

Type:

D

Catalog #

Project

Comments

Prepared by

Type

Date

SPECIFICATION FEATURES

07/08/2008 2:19:55 PMConsult your representative for additional options and finishes.

Specifications and Dimensions subject to change without notice. ADF051819

CEILING COMPATIBILITY

DOOR FRAMES

MOUNTING DATA LAMP CONFIGURATIONS

DESCRIPTION

Cooper Lighting introduces accord II(TM), a new recessed T5 or T8 fixture.

The accord II(TM) redefines fluorescent lighting by providing aesthetics, comfort and energy savings. The accord II(TM) provides increased comfort levels while providing significant energy savings.

The accord II(TM) is the ideal solution for offices, schools, hospitals, retail and other applications.

A ... Construction Shallow 3-3/4" deep housing is die formed of code gauge, prime cold rolled steel. Integral end plates are securely attached for strength and rigidity and the elimination of gaps. Four auxiliary fixture end suspension points are provided.

KOs for continuous row wiring.

Large access plate for supply connection.

B ... Electrical* Ballasts are Class "P" and are positively secured. Rotor-lock lampholders ensure positive lamp retention. UL/CUL listed. Suitable for damp locations.

C ... Ballast Access Ballast can be removed from below without tools.

D ... Finish Durable cold rolled steel with multistage, iron phosphate pretreatment and white enamel finish to ensure maximum bonding and rust inhibition.

E ... Reflectors Reflector has high reflectance baked white enamel finish for luminous uniformity.

F ... Shielding Positively retained frosted acrylic lenses and baffle provide a soft but effective distribution of light.

Spring loaded latch and T-hinge doorframe for ease of installation and maintenance.

2AC2

228T5

254T5

232T8

T5 OR T8 LAMPS

2' X 4' Recessed

Troffer Series

LAMPS CONTAIN MERCURY. DISPOSE ACCORDING

TO LOCAL, STATE OR FEDERAL LAWS

Safe and convenient means of disconnecting power

C ModularTr i m With Support i n g Swing Gates

C e i l i n g Tri m Ty p e Ty p e Exposed Grid G ConcealedT G Slot Grid G F l a n g e F Metal Pa n C

( Verify compatibility/ consult f a c t o r y. )

G G r i d / L a y- i n S t a n d a r d

G ConcealedT

G Slot Grid

F FlangeTr i m With Support i n g Swing Gates

GC8

Flat, White Steel

EB Ballast & STD Lamps @ 277V

228T5 (58) 232 (58)

254T5 (106)

Luminaire Efficacy Rating

LER =FL67

Catalog Number: 2AC2-228T5-PBW

Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.59

*Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements.

**Consult Pre SalesTechnical Support.

* * * See Drywall Frame Kit Accessory

E N E R G Y DATA

Input Watts:

A BC D FE

COOPER LIGHTING - METALUX ®

Submitting Agency: Description: 2AC2-232BI-UNV-L8835-EB81-U

Notes:

Type:

D

Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 07/08/2008 2:19:55 PM Specifications and Dimensions subject to change without notice. ADF051819

PHOTOMETRICS

ORDERING INFORMATION

2AC2

C o e ff i c ie nt s of U t i l i z at i on

Effective floor cavity reflectance 20% rc 80% 70% 50% 30% 10% 0% rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

RCR

Lu min an c e Da t a Average Average Average

Angle 0-Deg 45-Deg 90-Deg in Deg cd/sm cd/sm cd/sm 45 1666 1624 2047 55 1355 1514 1938 65 1052 1151 1257 75 956 935 1056 85 811 764 811

Zo n al Lu men Su mma ry

Zone Lumens %Lamp %Fixture 0-30 0-40 0-60 0-90 0-180

Angle Along II 45° Across

2AC2-228T5-BP

Electronic Ballast

(2) F 28T5 L amps 2900 Lumens each Spacing criterion:

(II) 1.1 x mounting height, ( ) 1.1 x mounting height Efficiency 66.8% Test Report:

2AC2-228T5PBW.IES

LER = FL67

Yearly Cost of 1000 lumens, 3000 hrs at

.08 KWH = $3.59

1712 1712 1712 1699 1705 1710 1651 1675 1697 1573 1623 1662 1481 1542 1562 1377 1425 1409 1262 1274 1250 1137 1112 1162 1005 955 1112 867 845 1065 724 746 996 572 639 818 419 511 523 327 358 391 252 252 304 182 178 201 115 110 117 52 49 52

0 0 0

79 79 79 79 78 78 78 78 74 74 74 71 71 71 68 68 68 67 73 70 68 65 71 69 66 64 66 64 62 63 62 60 61 60 59 57 67 62 58 54 65 61 57 54 58 55 52 56 54 51 54 52 50 49 62 55 50 46 60 54 49 45 52 48 45 50 47 44 49 46 43 42 57 49 44 39 55 48 43 39 47 42 39 45 41 38 44 40 38 36 52 44 38 34 51 43 38 34 42 37 34 41 37 33 40 36 33 32 49 40 34 30 47 39 34 30 38 33 30 37 33 30 36 32 29 28 45 36 31 27 44 36 31 27 35 30 27 34 30 26 33 29 26 25 42 33 28 24 41 33 28 24 32 27 24 31 27 24 31 27 24 22 39 31 25 22 38 30 25 22 30 25 22 29 25 22 28 24 22 20 37 28 23 20 36 28 23 20 28 23 20 27 23 20 26 22 20 19

1267 21.8 32.7 1978 34.1 51.1 3270 56.4 84.4 3873 66.8 100.0 3873 66.8 100.0

C o e ff i c ie n ts o f Ut i l i z at i o n

Effective floor cavity reflectance 20% rc 80% 70% 50% 30% 10% 0% rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

RCR

Lu min an c e Da t a Average Average Average

Angle 0-Deg 45-Deg 90-Deg in Deg cd/sm cd/sm cd/sm 45 1611 1655 2028 55 1322 1502 1893 65 1036 1148 1299 75 940 924 1045 85 780 749 795

Z on al Lu men Su mma ry

Zone Lumens %Lamp %Fixture 0-30 0-40 0-60 0-90 0-180

Angle Along II 45° Across

2AC2-232-BI

Electronic Ballast

(2) F3 2T8 L amps 3000 Lumens each Spacing criterion:

(II) 1.1 x mounting height, ( ) 1.2 x mounting height Efficiency 63.6% Test Report:

2AC2-232PBW.IES

LER = FL58

Yearly Cost of 1000 lumens, 3000 hrs at

.08 KWH = $4.15

1650 1650 1650 1637 1643 1646 1590 1613 1631 1516 1558 1590 1426 1475 1506 1325 1366 1404 1215 1242 1300 1095 1113 1200 970 986 1116 838 861 1055 703 745 966 558 634 799 412 503 592 322 357 404 249 249 292 179 176 199 113 110 118 50 48 51 0 0 0

76 76 76 76 74 74 74 74 71 71 71 68 68 68 65 65 65 64 70 67 64 62 68 65 63 61 63 61 59 60 59 57 58 57 56 54 64 59 55 52 62 58 54 51 56 52 50 54 51 49 52 49 48 46 59 52 47 43 57 51 47 43 49 46 42 48 44 42 46 43 41 40 54 47 41 37 52 46 41 37 44 40 37 43 39 36 41 38 36 34 50 42 36 32 48 41 36 32 40 35 32 39 35 32 38 34 31 30 46 38 32 29 45 37 32 28 36 32 28 35 31 28 34 31 28 26 43 35 29 25 42 34 29 25 33 28 25 32 28 25 31 28 25 24 40 32 26 23 39 31 26 23 30 26 23 30 25 22 29 25 22 21 37 29 24 21 37 29 24 21 28 24 21 27 23 20 27 23 20 19 35 27 22 19 34 27 22 19 26 22 19 25 21 19 25 21 19 17

1224 20.4 32.1 1933 32.2 50.6 3212 53.5 84.1 3818 63.6 100.0 3818 63.6 100.0

Candlepower Candlepower

SAMPLE NUMBER: 2AC2-228T5 -UNV-EBT1- .90 -U

Number of Lamps (Not included)

2=2 Lamp

Wattage (Length) 28T5=28W T5 (48")

54T5=54W T5HO (48")

32=32W T8 (48")

Voltage (1)

UNV=Universal Voltage 120-277

Series AC2=Accord II Series

Options GL=Single Element Fuse GM=Double Element Fuse Lamps=Lamps installed Flex=Flex Installed EL=Emergency Installed

Packaging U=Unit Pack PALC=Job Pack, in carton

Width 2 =2' Width

Shielding BP=Frosted Lens & White Baffle BI=Frosted Lens & Semi- Specular Baffle

Ballast Type EB8 =T8 Electronic Instant Start.

Total Harmonic Distortion < 20%

EB8 /PLUS=T8 Electronic Instant Start.

High Ballast Factor >1.13. Total Harmonic Distortion < 20%

ER8 =T8 Electronic Program Rapid Start.

Total Harmonic Distortion < 10%

EBT =T5 Linear Electronic Program Rapid Start Total Harmonic Distortion < 10%

No. of Ballast 1 or 2

No. of Ballast 1 or 2

No. of Ballast 1 or 2

No. of Ballast 1 or 2

Ballast Factor/Type (For 28W T5 Lamp Only) N=Normal Light Output .90 BF(2)

H=High Light Output 1.15 BF(2)

NDIM=Normal .9 BF Step Dimming(3)

HDIM=High 1.15 BF Step Dimming(3)

NOTES: (1) Products also available in non-US voltages and frequencies for international markets. (2) Step Dimming ballast available for 28W T5 lamps only. (3) .90 and 1.15 ballast factor available for 28W T5 lamps only.

For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.

2AC2-228T5 31 lbs.

2AC2-254T5 31 lbs.

2AC2-232 31 lbs.

S H I P P I N G I N F O R M AT I O N

Catalog No. Wt.

2 AC2 2 32 BI UNV L8835 EB81 U

Submitting Agency: Description: WN-232A-UNV-EB81-U

Notes:

Type:

E

COOPER LIGHTING

DESCRIPT ION

The WN Series is a specification wraparound luminaire featuring energy efficient performance. The luminaire's clean, low profile design is both appealing and functional. The WN Series utilizes a clear, low brightness, extruded acrylic refractor for high performance and aesthetics.

The efficient and stylish WN Series is the perfect wraparound for schools, offices and other commercial and retail spaces.

EB Ballast & STD Lamps

217 (36)

228T8 (48)

232 (55)

Luminaire Efficacy Rating

LER = FW-80

Catalog Number: WN-232A

Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.00

LER = FW-93

Catalog Number: WN-228T8-HB1

Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.59

*Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements.

WN

228T8

2 ' , 4 ' O R 8 ' S U R FA C E

T 8 L A M P S

Commerc ia l Wrap

ADF081637

E N E R G Y DATA

Input Watts:

SPEC IF ICAT ION FEATURES

A …C o n s t r u c t i o n

Housing consists of die formed cold rolled steel. Ends formed with the housing for strength and provisions for continuous row aligners. Steel end plates with 7/8" KO and light-seal embossment. Ballast cover easily removed without tools.

B …E l e c t r i c a l *

Ballasts are CBM/ETL Class "P" and are positively secured by mounting bolt. Rotor lock lam-pholders. UL/CUL listed.

Suitable for damp locations.

C …F i n i s h

Multistage, prepaint ensures maximum bonding and rust prevention.

Catalog # Type

Date

Project

Comments

Prepared by

COOPER LIGHTING - METALUX

LAMPS CONTAIN MERCURY. DISPOSE ACCORDING

TO LOCAL, STATE OR FEDERAL LAWS

Safe and convenient means of disconnecting power.

M O U N T I N G DATA

A B C D

2-1/2"

[63mm]

6"

[152mm]

7-5/8" [194mm]

6" [152mm]

1-1/8"

[29mm]

42-15/16" [1090mm]

44-1/2" [1131mm] 1-13/16"

[46mm]

90-7/8" [2309mm]

92-1/2" [2349mm]

96" [2440mm]

42-3/8" [1076mm]

41-3/8" [1051mm]

90-7/16" [2297mm]

88-7/16" [2246mm]

Ceiling Stand-Off Embossments

3"

[76mm] 4-1/2"

[114mm]

7-5/8" [194mm]

1-1/8"

[29mm]

42-15/16" [1090mm]

44-1/2" [1131mm] 1-13/16"

[46mm]

7/8" [22mm] K.O. (5)

Ground Screw Bump Ceiling Stand-Off Embossments

48" [1219mm]

42-7/16" [1078mm]

40-7/16" [1027mm]

3"

[76mm] 4-1/2"

[114mm]

6" [152mm]

7-5/8" [194mm]

1-13/16"

[46mm]

19" [483mm]

20-5/8" [523mm]

1-1/8"

[29mm]

24" [610mm]

8-3/16"

[208mm]

1"

[25mm]1" [25mm]

6" [152mm]

7-5/8" [194mm]

L E N S R E M OVA L

L A M P C O N F I G U R AT I O N S

6" [152mm]

2-1/2"

[63mm]

7-5/8" [194mm]

4-5/8"

[117mm]

D …L e n s

100% clear acrylic prismatic lens.

Sides have inside linear prisms and bottom has pyramidal prisms for low brightness control.

8'

4' 2'

Submitting Agency: Description: WN-232A-UNV-EB81-U

Notes:

Type:

E

Visit our web site at www.cooperlighting.com

Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 6/09 ADF081637

WN-217A 6 lbs.

WN-228T8A 8 lbs.

8TWN-228T8A 15 lbs.

WN-232A 8 lbs.

8TWN-232A 15 lbs.

S H I P P I N G I N F O R M AT I O N

Catalog No. Wt.

W N T 8

Ballast Type (3)

EB8 =T8 Electronic Instant Start.

Total Harmonic Distortion < 10%

EB8 /PLUS=T8 Electronic Instant Start.

High Ballast Factor >1.13.

Total Harmonic Distortion < 20%

REB1= T8 Electronic Instant Start Residential Ballast.

ER8 =T8 Electronic Program Rapid Start.

Total Harmonic Distortion < 10%

ER8 /PLUS=T8 Electronic Program Start.

High Ballast Factor >1.13.

Total Harmonic Distortion < 10%

HPT8 Ballast

HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77

HB8 =T8 Electronic Instant Start. Ballast Factor .88

HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0

HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2

HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88

HR8 L=T8 Electronic Program Start. Low Ballast Factor .77

HR8 =T8 Electronic Program Start. Ballast Factor .88

HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2

O R D E R I N G I N F O R M AT I O N

S A M P L E N U M B E R : W N - 2 3 2 A- U N V- E B 8 1- U

Number of Lamps (2)

2=2 Lamps (Not Included)

Voltage (3)

120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (4)

Wattage

17=17W T8 (24")

28T8=28W T8 (48") (6)

32=32W T8 (48")

Lens

A=Acrylic Refractor/Lens

Options

GL=Single Element Fuse

GM=Double Element Fuse

EL=Emergency Installed (5)

Series(1)

WN=Commercial

Surface Wrap

Length

Blank=2' or 4' Length

8T=8' (Tandem)

NOTES:

(1)

Steel endplates with 7/8" KO standard for continuous row mounting.

(2)

2 point suspension recommended (up to 4').

(3)

Products also available in non-US voltage and freqeuncies for international markets. 120V must be specified with a residential ballast.

(4) Not Available when specifying emergencies, voltage must be specified.

(5)

A low profile battery pack is required for installation with standard ballast cover (consult Cooper Lighting).

(6)

When utilizing 28W T8 lamps, HB Ballast must be specified. Other ballast restrictions may apply. Consult your Cooper Lighting Representative for availability and ordering information.

For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.

Options DEC=Decorative End Cap CRA=Continuous Row Aligner

Packaging

U=Unit Pack

No. of Ballast 1 or 2

No. of Ballast 1 or 2

No. of Ballast 1 or 2

No. of Ballast 1 or 2

A C C E S S O R I E S

SCF=Fixed Stem Set (Specify Length) SCS=Swivel Stem Set (Specify Length) SCA=Adjustable 48” Stem Set WN-2LT-DEC-ENDS=Decorative End Caps - 2 Lamps (2 pieces) WN-CRA=Continuous Row Aligner (24 pieces)

P H OTO M E T R I C S

Coeff i c i en ts o f Ut i l i za t ion

Effective floor cavity reflectance 20% rc 80% 70% 50% 30% 10% 0% rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

RCR

Zona l Lumen Summary

Zone Lumens %Lamp %Fixture

0-30

0-40

0-60

0-90

90-180

0-180

Cand lepower

Angle Along II 45° Across ⊥

WN-232-EB81-U

Energy Saving Ballast

F32T8/35K lamps 3100 lumens

Spacing criterion:

(II) 1.3 x mounting height, (⊥) 1.4 x mounting height

Efficiency = 82.0%

Test Report:

134P132

LER = FW-80

Yearly Cost of 1000 lumens, 3000 hrs at

.08 KWH = $3.00

1583 1583 1583

1588 1594 1591

1580 1597 1607

1554 1591 1618

1512 1573 1605

1454 1534 1563

1380 1473 1488

1291 1384 1375

1181 1258 1225

1043 1077 1030

848 851 809

602 655 626

429 518 512

317 413 444

240 333 409

180 270 390

123 223 369

62 185 347

3 155 332

95 95 95 95 92 92 92 92 85 85 85 80 80 80 74 74 74 72

86 82 79 76 83 80 76 73 74 72 69 69 67 65 65 63 61 59

79 72 67 62 76 70 65 61 65 61 58 61 58 55 57 54 52 50

72 64 57 52 69 62 56 51 58 53 49 54 50 47 51 47 45 42

66 57 50 45 64 55 49 44 52 46 42 49 44 40 46 42 39 37

61 51 44 39 59 49 43 38 47 41 37 44 39 35 41 37 34 32

57 46 39 34 54 45 38 33 42 36 32 40 35 31 38 33 30 28

52 42 35 30 50 41 34 29 38 33 29 36 31 28 34 30 27 25

49 38 31 27 47 37 31 26 35 30 26 33 28 25 32 27 24 22

46 35 28 24 44 34 28 24 32 27 23 31 26 22 29 25 22 20

43 32 26 22 41 31 26 22 30 25 21 29 24 20 27 23 20 18

1304 21.0 25.6

2152 34.7 42.3

3544 57.2 69.7

4441 71.6 87.3

645 10.4 12.7

5086 82.0 100.0

Typ ica l VCP Perc entages

Height Along Height Across

Room Size (Ft.) 8.5’ 10.0’ 8.5’ 10.0’

20 x 20

30 x 30

30 x 60

60 x 30

60 x 60

52 58 44 53

43 48 31 39

36 40 15 21

40 46 35 42

32 37 17 22

Coeff i c i en ts o f Ut i l i za t ion

Effective floor cavity reflectance 20% rc 80% 70% 50% 30% 10% 0% rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

RCR

Zona l Lumen Summary

Zone Lumens %Lamp %Fixture

0-30

0-40

0-60

0-90

0-180

Cand lepower

Angle Along II 45° Across ⊥

WN-228T8-HB81-U

Energy Saving Ballast

F28T8 28W lamps 2800 lumens

Spacing criterion:

(II) 1.3 x mounting height, (⊥) 1.4 x mounting height

Efficiency = 90.2%

Test Report:

134P133

LER = FW-93

Yearly Cost of 1000 lumens, 3000 hrs at

.08 KWH = $2.59

1562 1562 1562

1566 1572 1569

1558 1576 1586

1532 1570 1597

1490 1552 1586

1432 1514 1545

1358 1453 1472

1270 1365 1361

1162 1242 1214

1025 1063 1022

833 841 803

590 648 623

422 512 510

312 408 442

236 328 407

178 267 389

121 221 367

61 184 345

3 152 332

105 105 105 105 101 101 101 101 94 94 94 87 87 87 81 81 81 78

95 91 87 83 91 87 84 81 81 78 76 76 74 71 71 69 67 65

87 79 73 68 83 77 71 66 72 67 63 67 63 60 62 60 57 54

79 70 63 57 76 68 61 56 63 58 53 59 55 51 56 52 49 46

73 62 55 49 70 60 53 48 57 51 46 53 48 44 50 46 42 40

67 56 48 42 64 54 47 42 51 45 40 48 43 39 45 41 37 35

62 50 43 37 60 49 42 36 46 40 35 44 38 34 41 36 33 31

58 46 38 33 55 45 37 32 42 36 31 40 34 30 38 33 29 27

54 42 34 29 52 41 34 29 39 32 28 37 31 27 35 30 26 25

50 38 31 26 48 37 31 26 36 30 25 34 28 25 32 27 24 22

47 35 29 24 45 35 28 24 33 27 23 31 26 22 30 25 22 20

1286 23.0 25.5

2124 37.9 42.0

3498 62.5 69.2

4389 78.4 86.9

5052 90.2 100.0

Typ ica l VCP Perc entages

Height Along Height Across

Room Size (Ft.) 8.5’ 10.0’ 8.5’ 10.0’

20 x 20

30 x 30

30 x 60

60 x 30

60 x 60

52 58 44 54

43 49 31 40

36 40 15 21

41 47 35 43

33 37 17 22

WN 2 32 A UNV EB81 U

Interior Luminaires Reviewed.pdf
514 - 16510
14- Lighting
14- Lightingc
Sheet1
14- Lighting
Type A
Type B
Type C
Type D
Type E
Type DNL
Type LCP