Phase_3_Drawings_Issued_for_Construction_4-20-18.pdf
PDF 12 MB Posted
- Attached to
- Upgrade the Containment Lab, Otis PSDEL Federal contract opportunity
- Solicitation number
- 12639518R0035
About this file
Attachment 3--Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 12639518R0035-0005.pdf | ||
| RFIs_&_responses.pdf | ||
| RFIs_&_responses.pdf | ||
| General_Decision_Number_MA1.pdf | ||
| 12639518R0035-0004.pdf | ||
| RFI_01_Controlled_Environment_Rooms.docx | DOCX document | |
| 12639518R0035-0003.pdf | ||
| General_Decision_Number_MA1.pdf | ||
| 12639518R0035-0002.pdf | ||
| 12639518R0035-0001.pdf | ||
| General_Decision_Number_MA1.pdf | ||
| APHIS_PSEL_Phase_3_-_Final_Submittal_Specifications.pdf | ||
| 12639518R0035.pdf | ||
| General_Decision_Number_MA1.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TASK NO. : AG-6395-D-16-0408
APHIS
VICINITY MAP
N.T.S.
OVERALL SITE PLAN
N.T.S.
PROJECT LOCATION
CONNERY AVE.
BEAMAN RD.
LEE RD.
S. OUTER RD.
TR
U
C K
R D
S H
E L
TO
N R
D
CONTAINMENT LAB BLDG. 1398
PHASE 3A & 3B
BUILDING 1365
RENOVATION - PHASE 2
WAREHOUSE
PHASE 1
W. TRUCK ROAD
W. TRUCK ROAD
B E
A M
A N
R O
A D
LE
E R
OAD
PROJECT LOCATION
USDA/APHIS/PPQ/CPHST
ENGINEERING SERVICES BRANCH
4700 RIVER ROAD
RIVERDALE, MD 20737
P
I H
A
NO. DATE BY DESCRIPTION
DATE
PROJECT NO.
MERRICK PROJECT NO.
DESIGNER
DRAWN BY
PROJECT MANAGER
REAL PROPERTY
SAFETY & HEALTH
PPM
EPM
REVISIONS
OF
SHEET
A-E FIRM USDA
ENGINEERING SERVICES BRANCH
4700 RIVER ROAD
RIVERDALE, MD 20737
B. THOMPSON
64019314
AG-6395-D-16-0408
Animal and Plant Health Inspection Service
S
DATE: 4-20-18
CONTAINMENT LAB BUILDING 1398 - PHASE 3A & 3B
OTIS PEST SURVEY DETECTION AND EXCLUSION LAB
C.JOHNSTON
D.EVANS
4-20-18
COVER SHEET G-000
CONTAINMENT LAB BUILDING 1398 - PHASE
3A & 3B
DRAWING INDEX
Sheet Number Sheet Name
MECHANICAL
M-001 MECHANICAL SYMBOLS & ABBREVIATIONS
MD101 MECHANICAL DEMOLITION PLAN - PHASE 3A
MD102 MECHANICAL DEMOLITION PLAN-PHASE 3B
MD103 MECHANICAL ROOF DEMOLITION PLAN - PHASE 3A
MD104 MECHANIAL ROOF DEMOLITION PLAN - PHASE 3B
M-101 MECHANICAL FLOOR PLAN - PHASE 3A OVERALL
M-101a MECHANICAL FLOOR PLAN - PHASE 3A AREA A
M-101b MECHANICAL FLOOR PLAN - PHASE 3A AREA B
M-102 MECHANICAL FLOOR PLAN-PHASE 3B
M-103 MECHANICAL ROOF PLAN - PHASE 3A
M-104 MECHANICAL ROOF PLAN - PHASE 3B
M-105 HYDRONIC FLOOR PLAN - PHASE 3A
M-301 MECHANICAL SECTIONS
M-401 AIRFLOW DIAGRAMS
M-402 DIRECTIONAL AIRFLOW DIAGRAM - PHASE 3A
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-503 MECHANICAL DETAILS
M-601 MECHANICAL SCHEDULES
M-602 MECHANICAL SCHEDULES
M-701 MECHANICAL CONTROLS - ERUs
M-702 MECHANICAL CONTROLS - OFFICE AHU-2
M-703 MECHANICAL CONTROLS - HEATING WATER SYSTEM
M-704 MECHANICAL CONTROLS - LAB ROOMS
M-705 MECHANICAL CONTROLS - GENERAL EQUIPMENT
ELECTRICAL
E-001 ELECTRICAL LEGEND & ABBREVIATIONS
ED101 ELECTRICAL DEMOLITION PLAN - PHASE 3A
ED102 ELECTRICAL DEMOLITION PLAN - PHASE 3B
ED103 ROOF ELECTRICAL DEMOLITION PLAN - PHASE 3A
ED104 ROOF ELECTRICAL DEMOLITION PLAN - PHASE 3B
EP101 POWER PLAN - PHASE 3A
EP102 POWER PLAN - PHASE 3B
EP103 LAB PLATFORM POWER PLAN - PHASE 3A
EP104 ROOF POWER PLAN - PHASE 3A
EP105 ROOF POWER PLAN - PHASE 3B
EL101 LIGHTING PLAN - PHASE 3A
EL102 LIGHTING PLAN - PHASE 3B
EL103 LAB PLATFORM LIGHTING PLAN - PHASE 3A
ES101 ELECTRICAL SYSTEMS PLAN - PHASE 3A
ES102 ELECTRICAL SYSTEMS PLAN - PHASE 3B
E-501 ELECTRICAL DETAILS
E-502 ELECTRICAL DETAILS
E-503 ELECTRICAL DETAILS
E-601 ELECTRICAL DIAGRAMS
E-602 ELECTRICAL SCHEDULES
E-603 ELECTRICAL PANEL SCHEDULES
E-604 ELECTRICAL PANEL SCHEDULES
E-605 ELECTRICAL PANEL SCHEDULES
DRAWING INDEX
Sheet Number Sheet Name
GENERAL
G-000 COVER SHEET
G-001 CODE COMPLIANCE FLOOR PLAN
CIVIL
C-104 SCHEMATIC OVERALL SITE PLAN PHASE 3
STRUCTURAL
S-001 GENERAL NOTES AND ABBREVIATIONS
S-002 GENERAL NOTES SHEET 2
S-101 PARTIAL FOUNDATION PLAN
S-102 PARTIAL ROOF FRAMING PLAN
S-103 PARTIAL WINDOW FRAMING PLAN
S-104 PLATFORM PLAN
S-501 TYPICAL CONCRETE DETAILS
S-502 TYPICAL STEEL DETAILS
ARCHITECTURAL
A-001 ARCHITECTURAL LEGEND, ABBREVIATIONS AND GENERAL NOTES
A-002 OVERALL FLOOR PLAN
A-003 OVERALL ROOF PLAN
AD101 PSDEL LAB DEMOLITION FLOOR PLAN - PHASE 3A
AD102 LAB TO OFFICES CONVERSION DEMOLITION FLOOR PLAN - PHASE 3B
AD103 LAB TO OFFICES CONVERSION REFLECTED CEILING PLAN
DEMOLITION PLAN-PHASE 3B
AD104 LAB TO OFFICES CONVERSION PLATFORM DEMOLITION PLAN -
PHASE 3B
AD105 CONFERENCE TO OFFICE CONVERSION - PHASE 3B
A-101 PSDEL LAB FLOOR PLAN - PHASE 3A
A-102 PSDEL LAB REFLECTIVE CEILING PLAN
A-103 PSDEL PLATFORM FLOOR PLAN - PHASE 3A
A-104 LAB TO OFFICES CONVERSION FLOOR PLAN - PHASE 3B
A-105 LAB TO OFFICES CONVERSION REFLECTIVE CEILING PLAN
A-106 OFFICE CONVERSION FLOOR PLAN & RCP - PHASE 3B
A-107 PSDEL LAB FINISH FLOOR PLAN - PHASE 3A
A-108 LAB TO OFFICES CONVERSION FINISH FLOOR PLAN - PHASE 3B
A-109 OFFICE CONVERSION, FINISH, EQUIP. & FURNITURE FLR PLAN -
PHASE 3B
A-110 PSDEL LAB EQUIP. AND FURNITURE FLOOR PLAN - PHASE 3A
A-111 LAB TO OFFICES CONVERSION EQUIP. AND FURNITURE FLOOR PLAN
- PHASE 3B
A-201 EXTERIOR ELEVATIONS
A-202 INTERIOR ELEVATIONS
A-203 INTERIOR ELEVATIONS
A-301 WALL SECTIONS
A-302 WALL SECTIONS
A-401 ENLARGED FLOOR PLANS
A-402 ENLARGED FLOOR PLANS
A-403 ENLARGED PLAN & ELEVATIONS
A-501 PARTITION SCHEDULE AND DETAILS
A-502 CASEWORK DETAILS
A-503 DETAILS
A-504 EXTERIOR DETAILS
A-601 SCHEDULES
FIRE PROTECTION
FP001 FIRE PROTECTION LEGEND, ABBREVIATIONS AND GENERAL NOTES
FP101 FIRE PROTECTION PLAN - PHASE 3A
FP102 FIRE PROTECTION PLAN - PHASE 3B
FP501 FIRE PROTECTION DETAILS
PLUMBING
P-001 PLUMBING SYMBOLS & ABBREVIATIONS
PD101 PLUMBING DEMOLITION PLAN - UNDERSLAB
PD102 PLUMBING DEMOLITION PLAN
P-101 UNDERSLAB PLUMBING PLAN-PHASE 3A
P-102 UNDERSLAB PLUMBING PLAN-PHASE 3B
P-103 PLUMBING PLAN - PHASE 3A
P-104 PLUMBING PLAN - PHASE 3B
P-501 PLUMBING DETAILS
P-601 PLUMBING SCHEDULES
P-901 SANITARY ISOMETRIC PLAN
P-902 DOMESTIC WATER ISOMETRIC PLAN
P-903 NATURAL GAS ISOMETRIC PLAN
CONSTRUCTION PHASING REQUIREMENTS
PERFORM WORK IN THE FOLLOWING SEQUENCE:
1. COMPLETE DEMOLITION AND CONSTRUCTION OF PHASE 3A
2. PERFORM COMMISSIONING OF PHASE 3A. AS DIRECTED BY GOVERNMENT'S 3RD - PARTY COMMISSIONING AGENCY. PROVIDE CORRECTIONS REQUIRED BY
COMMISSIONING AND CERTIFICATION PROCESS AND OBTAIN FINAL APPROVAL OF COMPLETED CONSTRUCTION. ALLOW GOVERNMENT TO MOVE
FURNITURE AND EQUIPMENT OUT OF PHASE 3B AREA AND INTO 3A AREA.
3. PERFORM REQUIRED DEMOLITION AND CONSTRUCTION IN PHASE 3B AREA.
Attachment 3
87'-0" 19'-6"
115'-6" 55'-0"
114'-6" 40'-0"
98'-0"
62'-0" 27'-0" 16'-0"
109'-6" 49'-0"
129'-6" 33'-6" 18'-0"
100'-0" 42'-0" 19'-0"
95'-0"
FEC
FEC
FEC
FEC
FEC
7-XD 21-XD
54-XD21-XD
2 1
1 2
1 1 2
LIFE SAFETY LEGEND:
FIRE EXTINGUISHER CABINET
COMMON PATH
DF
TOTAL TRAVEL DISTANCE
COMMON PATH OF TRAVEL
DEAD END CORRIDOR LENGTH
DRINKING FOUNTAIN
X'-X"
FEC
EXIT SIGN
OCCUPANT LOAD OF ROOM
X'-X" X'-X"
TRAVEL DISTANCE
X
XX-XD
NUMBER OF OCCUPANTS
POINT OF EXIT DISCHARGE
1 HOUR RATED WALL
CONTAINMENT BOUNDARY
SMOKE PARTITION
OVERALL BUILDING 1398 REMODEL CODE
COMPLIANCE SUMMARY
OCCUPANCIES
BUSINESS
EXISTING ASSEMBLY
EXISTING BUSINESS
BAY WINDOW
GREENHOUSE
MICROSCOPE
FUM TREAT
85A
COMMODITY
TREATMENT
LOG
WOOD ROOM
BIOCONTROL
VESTIBULE-B
VESTIBULE-A
SMALL
CONFERENCE
13A
VOUCHER ROOM
OFFICE-B
13B
OFFICE-C
13C
O F
F
IC
E -D
D
WORKROOM
53 GENERAL STORAGE
53B
IT
S T
O R
A G
E
A
CONFERENCE
52B
CORRIDOR
C-2
OPEN OFFICE
VESTIBULE-C
73A
WIND TUNNEL
MECHANICAL
SMALL INSECT /
UNPACKING
HOOD
79A
JANITORIAL
72B
MOTH REARING
WOOD BORER
ALB CHAMBER
75A
GC EAD
BIO ASSAY-2
72E
BIO ASSAY-1
72D
AERATION
80A
ENVIRONMENTAL
CHAMBER
(PERCIVAL) ROOM
MOTH CHAMBER
78A
COMMON AREA
SMALL
CONFERENCE / VTC
DIRECTOR'S OFFICE
OFFICE-C
12C
OFFICE-A
12A
OFFICE-B
12B
VESTIBULE-D
72F
CORRIDOR-2
72C
CORRIDOR-1
72A
UNISEX TOILET
ALCOVE
74A
EXISTING LUNCH
ROOM
52A
CORRIDOR
C-11
WALK-IN CHAMBER
77A
CORRIDOR
C-3
C O
R R
ID
O
R
A
CORRIDOR
C-12
CLOSET
12D
NO. DATE BY DESCRIPTION
DATE
PROJECT NO.
MERRICK PROJECT NO.
DESIGNER
DRAWN BY
PROJECT MANAGER
REAL PROPERTY
SAFETY & HEALTH
PPM
EPM
REVISIONS
OF
SHEET
A-E FIRM USDA
B. THOMPSON
64019314
AG-6395-D-16-0408 ENGINEERING SERVICES BRANCH
4700 RIVER ROAD
RIVERDALE, MD 20737
P
I H
A Animal and Plant Health Inspection Service
S
C.JOHNSTON
D.EVANS
4-20-18
G-001
CONTAINMENT LAB BUILDING 1398 - PHASE
3A & 3B
CODE COMPLIANCE FLOOR PLAN
1/16" = 1'-0"1
CODE COMPLIANCE FLOOR PLAN
16 12 8 4 0 16 32
BUILDING CODE ARS 242.01 DIRECTS THE FOLLOWING:
2015 IBC OR NFPA 101 LIFE SAFETY CODE
IBC WILL BE FOLLOWED FOR BUILDING CODE
COMPLIANCE AND NFPA 101 WILL BE FOLLOWED FOR
EGRESS REQUIREMENTS, IN LIEU OF IBC CHAPTER 10.
UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR
FACILITIES, WITH CHANGE 1
AUTHORITY HAVING
JURISDICTION (AHJ)
JOINT BASE FIRE MARSHALL
OCCUPANCY MIXED: EXISTING BUSINESS CHAPTER 39 (IBC B), NEW
BUSINESS CHAPTER 38 (IBC B) AND EXISTING ASSEMBLY
CHAPTER 13 (IBC A-3).
BUILDING SIZE 32,500 SF; ONE STORY; 17’-4” HIGH POINT, 13’-2-1/2” LOW
POINT; AVERAGE ROOF HT 15’-10-1/2” FT
CONSTRUCTION TYPE STEEL SUPERSTRUCTURE AND WOOD PLATFORMS; TYPE
V B, FULL SPRINKLER SYSTEM.
ALLOWABLE AREA AND HEIGHT LIMITED BY A-3 OCCUPANCY TO 32,512 SF (TABLE 506.2);
2 STORIES (TABLE 504.4); 60 FEET HEIGHT (TABLE 504.3).
(NOTE THAT ALLOWABLE AREA MAY ALSO BE INCREASED
FOR OPEN AREA ON 3 SIDES OF BUILDING)
OCCUPANT LOAD (ENTIRE
BLDG)
[(844 SF + 1080 + 182 + 242) ÷ 15 SF/PERSON] + [(32500 -
2348 SF) ÷ 100 SF/PERSON] = 157 + 302 = 459.
NUMBER OF EXITS REQUIRED 2 EXITS REQUIRED; 2 EXITS PROVIDED. 4 GENERAL
BUILDING EXITS PROVIDED.
REQUIRED EGRESS WIDTH 98" REQUIRE; 128" PROVIDED
ALLOWABLE TRAVEL DISTANCE
TO EXIT
250 FT (ASSEMBLY AND INDUSTRIAL); 300 FT (BUSINESS);
ACTUAL MAXIMUM TRAVEL DISTANCE IS 115.5 FT
ALLOWABLE COMMON PATH OF
TRAVEL
75 FEET FOR MAXIMUM 50 PERSONS AND 20 FEET FOR
ANY NUMBER; ACTUAL MAXIMUM COMMON PATH FOR 50
LIMITATION IS 52 FEET; ACTUAL MAXIMUM COMMON PATH
FOR OCCUPANCY OVER 50 IS ZERO.
DEAD END CORRIDORS MAXIMUM 20 FEET ALLOWABLE; ACTUAL 19 FEET.
REQUIRED FIRE RATINGS 1 HOUR FIRE RATED GAS BOTTLE STORAGE
16 12 8 4 0 16 32
1/16" = 1'-0"2
CODE COMPLIANCE OCCUPANCY FLOOR PLAN
UE UE
W
W
W
W
W
W
W
W
W
W
W
X
X
XX
X X
X
X X X
X
L
E
R
O
A
D
EX BUILDING
EX BUILDINGS
EX BITUMINOUS PAVEMENT
EX ELECTRIC
POLE
EX PARKING
EX 8" FIRE LINE
NEW LOCATION OF 7 CONDENSING UNITS
ON CONCRETE PADS
LIMITS OF PHASE 3
EX. FENCE
ERU NEW LOCATION
ON CONCRETE PADS
EX. FENCE
EX. CONCRETE SLAB
5.67'
REFRIGERATOR
TO REMAIN
EX PSDEL LAB ANNEX
(7) 8" BURIED CONDUITS FOR REFRIGERANT PIPING.
CONTRACTOR TO COORDINATE WITH PLATFORM
FOOTINGS. SEE UTILITY TRENCH DETAIL ON THIS SHEET.
EX. GATE TO BE
RELOCATED
7.75'
EX. GATE TO BE
RELOCATED
200 S.F. ± OF CONCRETE SLAB TO BE REMOVED.
CONTRACTOR TO LEAVE ENOUGH CONCRETE
SLAB TO ACCOMMODATE RELOCATION OF
WOODEN SHED.
11.00'
GUARD RAIL
RE: A-101 FOR
DIMENSIONS & SPECS
3.00'
EX. CHEMICAL
STORAGE
TO REMAIN
EX. WOODEN SHED TO BE RELOCATED TO
SOUTHERN-MOST PART OF CONCRETE PAD.
2.50'
2" SCHEDULE 40 PVC
POWER CONNECTION & COMM LINE
SEE ELECTRIC/COMM TRENCH
DETAIL BELOW
RE: EP101 & E-503 FOR CHEMICAL
STORAGE SERVICE INFO
T
T
(7) 1" BURIED CONDUITS
FOR POWER CONNECTION
RE: EP101
MEZZANINE ACCESS PLATFORM
RE: S-104
CONDUITS FOR REFRIGERANT PIPING TO ENTER
MECH ROOM 83 THROUGH WALL OVERHEAD.
RE: M-105 FOR DETAILS
2.50'
EX. WATERLINE
TO BE REMOVED
NO. DATE BY DESCRIPTION
DATE
PROJECT NO.
MERRICK PROJECT NO.
DESIGNER
DRAWN BY
PROJECT MANAGER
REAL PROPERTY
SAFETY & HEALTH
PPM
EPM
REVISIONS
OF
SHEET
A-E FIRM USDA
FACILITIES DIVISION
K. DESJARDINS
4-20-18 64019314
T. KELTS
AG-6395-D-16-0408
ISSUED FOR CONSTRUCTION
MERRICK
& COMPANY
R
P
I H
A Animal and Plant Health Inspection Service
S
ENGINEERING SERVICES BRANCH
4700 RIVER ROAD
RIVERDALE, MD 20737
VICINITY MAP
N.T.S.
PROJECT LOCATION
C
O
N
N
E
Y
A
V
E
SITE PLAN PHASE 3
1" = 20'
1" = 20'
40'20'10'20'
S
H
E
L
T
N
D
L
T
R
U
C
K
B
E
A
M
N
S
U
T
SCHEMATIC OVERALL
SITE PLAN PHASE 3 C-104
PIPE BEDDING
BACKFILL
BEDDING TRENCH BACKFILL
REFER TO PAVEMENT
DETAIL
ELECTRIC/COMM TRENCH
DETAIL
NTS
1.00' 1.00'
1' MIN
1.5' MAX
6"
DETECTABLE WARNING TAPE
3,000 PSI CONCRETE.
PROVIDE REBAR AS REQUIRED.
4"
4" 4"
4"
2" SCHEDULE 40 PVC
GENERAL NOTES:
1. ALL ITEMS LABELED ON THE PLANS ARE PROPOSED UNLESS OTHERWISE NOTED.
2. THE CONTRACTOR SHALL OBTAIN UTILITY LOCATIONS PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. UTILITIES SHOWN
ARE APPROXIMATE AND BASED ON RECORD DRAWINGS.
3. EXISTING INFORMATION AS SHOWN ON THIS PLAN WAS OBTAINED BY MERRICK FROM USDA APHIS. INFORMATION WAS BASED
ON RECORD DRAWINGS.
4. DIMENSIONS SHOWN FROM BUILDINGS UTILIZE THE RECORD INFORMATION PROVIDED AS DESCRIBED IN NOTE 3. FIELD VERIFY
THE DIMENSIONS AND LAYOUT PRIOR TO CONSTRUCTION.
5. UNITS ARE SHOWN IN FEET AND INCHES.
6. EXISTING BITUMINOUS PAVEMENT TO BE GROUND AND REUSED AS ROADWAY BASE MATERIAL OR REMOVED OFF SITE.
7. DESIGN IS BASED ON ASSUMED PROPERTY LINE AND BOUNDARY INFORMATION. THE BOUNDARY AS CALLED ON THIS PLAN IS
ASSUMED TO BE THE LEGAL BOUNDARY OF THE COMPLEX. NOTIFY USDA APHIS OF ANY DISCREPANCIES.
8. UTILITY INFORMATION SHOWN REPRESENTS THE INFORMATION AVAILABLE TO MERRICK. IT IS ASSUMED THAT UNDERGROUND
UTILITIES WILL NOT AFFECT CONSTRUCTION. NOTIFY USDA APHIS OF ANY DISCREPANCIES AFTER FIELD VERIFICATION.
9. UTILITIES DAMAGED ABOVE OR BELOW GROUND SHALL BE REPAIRED BY THE CONTRACTOR AT NO COST TO THE
GOVERNMENT.
10. POSSIBLE TREE LOCATIONS WERE NOT AVAILABLE TO MERRICK DURING DESIGN. TREES WHICH INTERFERE WITH
CONSTRUCTION SHALL BE REMOVED. ADDITIONALLY, USDA APHIS WILL FLAG ADDITIONALLY TREES WHICH MAY BE TOO CLOSE
TO BUILDINGS AND WHICH REPRESENT A SECURITY THREAT. TREES FLAGGED BY USDA APHIS SHALL ALSO BE REMOVED.
11. DURING CONSTRUCTION, THE CONTRACTOR SHALL MAINTAIN SECURITY FOR THE FACILITY PER GUIDANCE FROM USDA APHIS.
LEGEND:
SAWCUT
UNDERGROUND ELECTRIC SERVICE
EXISTING FENCE
PHASE 1 LIMITS
PAVEMENT AREA TO BE REPLACED
CONCRETE PAD TO BE REMOVED
X
UE
SEE TRENCH DETAIL NOTE 2
TRENCH DETAIL NOTES:
1. THE CONTRACTOR SHALL RESTORE ALL PAVEMENTS AND GRADES AS REQUIRED TO MATCH EXISTING PAVEMENTS.
2. INSTALL #2 COPPER GROUND WIRE WITHIN CONCRETE DUCT BANK. GROUND TO SYSTEM GROUND SUCH AS BUILDING
ELECTRICAL SERVICE, TELEPHONE GROUND BUS AND MANHOLE GROUND RODS.
3. INSTALL PULL WIRE IN CONDUIT.
UTILITY TRENCH DETAIL
NTS
TRENCH DETAIL NOTES:
1. PROVIDE BEDDING IN ACCORDANCE WITH SPECIFICATIONS.
2. PROVIDE TRACER WIRE AND WARNING TAPE IN ACCORDANCE
WITH SPECIFICATIONS.
3. COMPACT BACKFILL TO SPECIFICATION REQUIREMENTS.
4. MAINTAIN A MINIMUM OF 18" VERTICAL SEPARATION BETWEEN
GAS LINE AND OTHER UTILITIES.
FINISH GRADE
NATIVE BACKFILL MATERIAL
PIPE
DETECTION WIRE OVER
NON-METALLIC PIPE TYP.
UNDISTURBED EARTH
6" MIN CLEAN
BEDDING
CLEAN BEDDING TO 6"
ABOVE TOP OF PIPE
INITIAL BACKFILL
VARIES
12" (6" BELOW
PAVEMENT)
PIPE OD + 1'
PIPE OD + 12" MIN
TO 24" MAX
VARIES MIN WIDTH REQ'D FOR
SAFE UTILITY INSTALLATION
PER OSHA REQUIREMENTS
UTILITY MARKING TAPE OVER
CENTERLINE OF PIPE BELOW
W
W
W
W W W W
W W
" PVC DOMESTIC WATER LINE.
SEE UTILITY TRENCH DETAIL ON THIS
SHEET. COORDINATE ROUTING WITH
DUCTWORK SUPPORT FRAME AND
CONCRETE PADS. CONTRACTOR TO
COORDINATE FINAL ROUTING WITH
USDA APHIS.
PRIME COAT
TACK
COAT
NEW
HOT MIX
SURFACE
COURSE
EXISTING BITUMINOUS
PAVEMENT
FULL-DEPTH SAWCUT
EXISTING ASPHALT
FLEXIBLE PAVEMENT EXISTING EARTH GRADE
EXISTING
UNDERLYING
MATERIAL
CONTAINMENT LAB BUILDING 1398 - PHASE
3A & 3B
4/20/18
DESIGN CRITERIA
GRAVITY LOADS IN ACCORDANCE WITH UFC 3-301-01, STRUCTURAL LOAD DATA.
1 JUNE 2013 (WITH CHANGE 3, 12 SEPTEMBER 2016), UFC 4-010-01, DoD MINIMUM
LOCATION
OTHER LIVE LOADS NOT SHOWN SHALL BE IN ACCORDANCE WITH ASCE 7, MINIMUM
DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES. MINIMUM DESIGN ROOF
LATERAL LOADS:
WIND LOADS:
IN ACCORDANCE WITH UFC 3-310-01, STRUCTURAL LOAD DATA AND ASCE 7,
MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES.
BASIC WIND SPEED
WIND IMPORTANCE FACTOR
WIND EXPOSURE CATEGORY
SEISMIC CRITERIA FOR NEW STRUCTURE:
DETERMINED IN ACCORDANCE WITH UFC 1-200-01 AND IBC 2015, BY INCORPORATING
THE FOLLOWING PARAMETERS:
OCCUPANCY CATEGORY
SITE CLASSIFICATION
SHORT PERIOD SPECTRAL ACCELERATION
ONE SECOND SPECTRAL ACCELERATION
SEISMIC DESIGN CATEGORY
SEISMIC IMPORTANCE FACTOR
ANTITERRORISM STANDARDS FOR BUILDING, 09 FEBRUARY 2012 (WITH CHANGE
UNIFORM CONCENTRATED
LIVE LOAD LIVE LOAD
ROOF 20 PSF (MIN.) OR CONTROLLING SNOW LOAD
PLATFORM 40 PSF
1, 1 OCTOBER 2013),UFC 4-023-03 DESIGN OF BUILDINGS TO RESIST PROGRESSIVE
COLLAPSE, 14 JULY 2009 (WITH CHANGE 3, 1 NOVEMBER 2016), ASCE 7, MINIMUM
DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES AND IBC 2015:
OTHER STRUCTURES.
GROUND SNOW LOAD
ROOF SLOPE FACTOR
SNOW THERMAL FACTOR
SNOW IMPORTANCE FACTOR
ROOF EXPOSURE FACTOR
FLAT ROOF SNOW LOAD
SLOPED ROOF SNOW LOAD
Pg Cs Ct I Ce Pf Ps
30 PSF
1.0 1.0 1.0 0.9
18.9 PSF
18.9 PSF
p = 0.00256*Kz*Kzt*Kd*V^2*I
140 MPH
1.00 (CATEGORY II)
V I C
II
D Ss S1 C 1.00
0.22g 0.058g
STRUCTURAL LOAD DATA AND ASCE 7, MINIMUM DESIGN LOADS FOR BUILDINGS AND
STRUCTURAL PLANS INDICATE ONLY THE APPROXIMATE LOCATION OF MECHANICAL,
ELECTRICAL AND OTHER EQUIPMENT, AS WELL AS THE RELATED AUXILIARY FRAMING
NECESSARY TO SUPPORT SUCH EQUIPMENT. THE FINAL POSITIONING OF THESE
ITEMS IS DEPENDENT UPON THE EQUIPMENT PROVIDED. THE CONTRACTOR SHALL BE
IN THIS REGARD, AND PROVIDING NECESSARY DIMENSIONS IN A TIMELY MANNER TO
ALL PARTIES INVOLVED. THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING AS
ROOF AND FLOOR MEMBERS. BRACING MUST BE FULLY EFFECTIVE UNTIL ROOF AND
FLOOR DEAD LOADS ARE IN PLACE.
CONCRETE GRADE WALLS SHALL BE TEMPORARILY BRACED IF BACKFILL IS ONLY ON
ONE SIDE OR THEY SHALL BE BACK FILLED ON BOTH SIDES SIMULTANEOUSLY, WHERE
REQUIRED, TO PREVENT DEFLECTION, CRACKING OR FAILURE OF CONCRETE GRADE
EXPANSION ANCHORS CAN ONLY BE USED FOR FIELD REPAIRS AND REQUIRE
APPROVAL OF THE CONTRACTING OFFICER. REFER TO "POST INSTALLED CONCRETE
14.
15.
RESPONSIBLE FOR COORDINATING WORK BETWEEN SUBCONTRACTORS AND CRAFTS
REQUIRED DURING THE ERECTION OF THE STRUCTURAL FRAME.
16.
17.
ANCHORS" SECTION OF GENERAL NOTES FOR ADDITIONAL INFORMATION.
CONSTRUCTION METHODS AND PROJECT SAFETY: THE CONTRACT DRAWINGS AND
SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE AND DO NOT INDICATE
METHODS, PROCEDURES OR SEQUENCE OF CONSTRUCTION. THE CONTRACTOR
SHALL TAKE NECESSARY PRECAUTIONS TO MAINTAIN AND ENSURE THE INTEGRITY OF
CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING AND BRACING,
AND BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL APPLICABLE LOCAL, STATE
ANY DEVIATION FROM THE APPROVED SET OF STRUCTURAL DRAWINGS SHALL ONLY
BE MADE AFTER WRITTEN APPROVAL BY THE CONTRACTING OFFICER.
12.
13.
THE STRUCTURE DURING CONSTRUCTION. THE CONTRACTOR SHALL DESIGN,
AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS; OSHA
WALLS.
GENERAL REQUIREMENTS
VERIFICATION: VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE CONDITIONS BEFORE
STARTING WORK. NOTIFY THE CONTRACTING OFFICER IMMEDIATELY OF ANY
CONFLICTS: NOTES AND DETAILS ON THE DRAWINGS TAKE PRECEDENCE OVER THE
CODES: ALL MATERIALS AND WORK SHALL CONFORM TO THE REQUIREMENTS OF THE
LATEST CODES, UFCS AND ASCE 7.
SUBSTITUTIONS: PROVIDE MANUFACTURER'S ICC REPORTS AND A LIST OF ALL
PROPOSED SUBSTITUTIONS TO THE CONTRACTING OFFICER FOR REVIEW BEFORE
SIMILAR WORK: WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY
PART OF THE WORK, SUCH DETAILS SHALL BE THE SAME AS FOR SIMILAR WORK
PIPES, DUCTS, SLEEVES, CHASES, ETC.: SHALL NOT BE PLACED IN SLABS, BEAMS, OR
WALLS UNLESS SPECIFICALLY SHOWN OR NOTED NOR SHALL ANY STRUCTURAL
MEMBER BE CUT FOR PIPES, DUCTS ETC., UNLESS SPECIFICALLY SHOWN. OBTAIN
PRIOR WRITTEN APPROVAL FROM THE CONTRACTING OFFICER FOR INSTALLATION OF
EXCAVATIONS: LOCATE AND PROTECT UNDERGROUND OR CONCEALED CONDUIT,
PLUMBING OR OTHER UTILITIES WHERE NEW WORK IS BEING PERFORMED.
CONSTRUCTION LOADS: MATERIALS SHALL BE EVENLY DISTRIBUTED IF PLACED ON
FRAMED FLOORS OR ROOFS. LOADS SHALL NOT EXCEED THE ALLOWABLE LOADING
FOR THE SUPPORTING MEMBERS AND THEIR CONNECTIONS.
THE STRUCTURAL DRAWINGS ILLUSTRATE THE NEW STRUCTURAL MEMBERS, REFER
TO ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR NON-STRUCTURAL
ITEMS WHICH REQUIRE SPECIAL PROVISIONS DURING THE CONSTRUCTION OF
REFER TO ARCHITECTURAL PLANS FOR FLOOR DEPRESSIONS, SLOPES, DRAINS,
CURBS, PADS, EMBEDDED ITEMS, NON-BEARING PARTITIONS, ETC.
REFER TO MECHANICAL AND ELECTRICAL PLANS FOR SLEEVE AND HANGERS FOR
PIPES, DUCTS AND EQUIPMENT.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
SHOWN ON DRAWINGS.
STRUCTURAL MEMBERS.
DISCREPANCIES.
GENERAL NOTES AND TYPICAL DETAILS IN CASE OF CONFLICT.
ANY ADDITIONAL PIPES, DUCTS, ETC.
FABRICATION.
REQUIREMENTS; AND EM385-1-1.
ABV
ADDL
HT
HSH
HSB
HORIZ
HGR
HDR
HD
(H)
GR
GLB
GALV
GA
FTG
FS
FRMG
FOS
FOM
FOC
FN
FLR
FLG
FJ
FFE
FDN
EW
ES
EQ
EN
EMBED
ELEV
ELEC
EL
EF
EA
(E)
DWL
DWG
DP
DO
DN
DIM
DIA
DF
DBL
CTRD
CSK
CP
CONT
CONST
CONN
CONC
COL
CLR
CL
CJ
CJ
CIP
CB
C
BTWN
BRG
BP
BOS
BOF
BN
BM
BLW
BLKG
BLK
(B)
AWS
ASSOCIATION
AWPA
TESTING AND MATERIALS
ASTM
ASD
ARCH
ASSOCIATION
APA
ALT
STEEL CONSTRUCTION
AISC
ADJ
WWF
WT
WPJ
WP
WD
W/O W/
WL
VSH
VERT
(V)
UON
UNO
UBC
TYP
TS
TOW
TOT
TOS
TOP
TOC
TO
TN
THRD
THK
TG
T AND B
(T)
STRUC
STL
STIFF
STGR
STD
SQ
SPEC
SOG
SIM
SHTHG
SEP
SECT
SCHED
SC
RF
REF
REQD
REINF
R P.T.
PP
PLYWD
PLCS
PL
PC
ORIG
OPP
OPNG
OH
OF
OC
NTS
NS
NO
NIC
MTL
MISC
MIN
MFR
MECH
MB
MAX
MATL
LT WT
LOC
LDGR
KP
JT
JST
IF
ABBREVIATIONS
AB ANCHOR BOLT ICC INTERNATIONAL CODE
COUNCILABOVE
ADDITIONAL
INSIDE FACEADJACENT
JOISTAMERICAN INSTITUTE OF
JOINT
KING POSTALTERNATE
LEDGERAMERICAN PLYWOOD
LOCATION
LIGHTWEIGHTARCHITECTURAL/ARCHITECT
MATERIAL
MAXIMUM
ALLOWABLE STRESS DESIGN
AMERICAN SOCIETY FOR
MACHINE BOLT
MECHANICALAMERICAN WOOD PRESERVERS
MANUFACTURER
MINIMUM
MISCELLANEOUS
AMERICAN WELDING SOCIETY
BOTTOM
METALBLOCK
NOT IN CONTRACTBLOCKING
NUMBERBELOW
NEAR SIDEBEAM
NOT TO SCALEBOUNDARY NAIL
ON CENTERBOTTOM OF FOOTING
OUTSIDE FACEBOTTOM OF STEEL
OPPOSITE HANDBASE PLATE
OPENINGBEARING
OPPOSITEBETWEEN
ORIGINALCAMBER
PRECASTCARRIAGE BOLTS
PLATE
CAST-IN-PLACE PLACES
CONSTRUCTION JOINT PLYWOOD
CEILING JOIST PARTIAL PENETRATION
CENTER LINE POST-TENSION
CLEAR RADIUS
COLUMN REINFORCEMENT
CONCRETE REQUIRED
CONNECTION REFERENCE
CONSTRUCTION ROOF
CONTINUOUS SHEAR CONNECTOR
COMPLETE PENETRATION SCHEDULE
COUNTER SINK
SECTIONCENTERED
SEPARATIONDOUBLE
SHEATHINGDOUGLAS FIR/LARCH
SIMILARDIAMETER
SLAB ON GRADE
DEEP
SPECIFICATION
DIMENSION
SQUARE
DOWN
STANDARD
DITTO (REPEAT)
STAGGERDRAWING
STIFFENERSDOWEL
STEELEXISTING
STRUCTURALEACH
TOPEACH FACE
TOP AND BOTTOM
ELEVATION TAPERED GIRDER
ELECTRICAL THICKNESS/THICK
ELEVATOR THREADED
EMBEDMENT TOENAIL
EDGE NAIL TOP OF
EQUAL OR EQUIVALENT TOP OF CONCRETE
EACH SIDE TOP OF PARAPET
EACH WAY TOP OF STEEL
FOUNDATION TOTAL
FINISHED FLOOR ELEVATION TOP OF WALL
FLOOR JOIST TUBE STRUCTURAL
FLANGE TYPICAL
FLOOR UNIFORM BUILDING CODE
FIELD NAIL UNLESS NOTED OTHERWISE
FACE OF CONCRETE UNLESS OTHERWISE NOTED
FACE OF MASONRY VERTICAL
FACE OF STUD VERTICAL
FRAMING VERTICAL SLOTTED HOLES
FAR SIDE WIND LOAD
FOOTING WITH
GAUGE
WITHOUT
GALVANIZED
WOOD
GLUED LAMINATED BEAM
WATER PROOF/WORK POINT
GRADE
WEAKENED PLANE JOINT
HORIZONTAL
WEIGHT
HOLDOWN
WELDED WIRE FABRIC
HEADER
HEIGHT
HORIZONTALLY SLOTTED HOLES
HIGH STRENGTH BOLT
HORIZONTAL
HANGER
CGS CENTER OF GRAVITY OF STEEL
GSN GENERAL STRUCTURAL NOTES
5/- INDICATES A SECTION OR DETAIL
THAT APPEARS ON THE SAME SHEET
AS THE REFERING INFORMATION.
EF EDGE FASTENER
FY YIELD STRENGTH
SCJ SHRINKAGE CONTROL JOINT
I.E. INSIDE FACESOILS INFORMATION BASED ON "GEOTECHNICAL INVESTIGATION REPORT,
PROPOSED USDA BUILDING ADDITION" BY BRIGGS ENGINEERING AND
TESTING DATED NOVEMBER 12, 2016.
FOUNDATION:
1.
FOOTINGS ARE DESIGNED BASED ON THE FOLLOWING INFORMATION:
ALLOWABLE BEARING * = 4000 PSF (AT -4'-0" BELOW FINISHED FLOOR)
EQUIVALENT FLUID PRESSURE = 60 PCF
PASSIVE EARTH PRESSURE = 200 PCF
COEFFICIENT OF FRICTION = 0.4
MODULUS OF SUB
-GRADE REACTION = 150 PCI
* ALLOWABLE BEARING MAY BE INCREASED BY 1/3 FOR WIND OR SEISMIC LOADS
FOOTING SHALL BEAR ON FIRM SELECT FILL SOILS. MINIMUM DEPTH OF FOOTINGS
BELOW LOWEST ADJACENT FINAL GRADE SHALL BE 48". MINIMUM WIDTH OF FOOTING
SHALL BE 24".
CONTRACTOR SHALL PROVIDE FOR DE-WATERING OF EXCAVATIONS FOR EITHER
SURFACE WATER, GROUND WATER, OR SEEPAGE, IF REQUIRED.
CONTRACTOR SHALL PROVIDE FOR DESIGN AND INSTALLATION OF ALL CRIBBING,
SHEATHING, AND SHORING REQUIRED; AND SHALL BE SOLELY RESPONSIBLE FOR ALL
EXCAVATION PROCEDURES INCLUDING LAGGING, SHORING, AND PROTECTION OF
ADJACENT PROPERTY, STRUCTURES, STREETS AND UTILITIES IN ACCORDANCE WITH
ALL NATIONAL, STATE, AND LOCAL SAFETY ORDINANCES.
ALL EXCAVATIONS SHALL BE PROPERLY BACKFILLED. DO NOT PLACE BACKFILL
BEHIND RETAINING WALLS BEFORE CONCRETE OR GROUT HAS ATTAINED FULL DESIGN
STRENGTH. CONTRACTOR SHALL BRACE OR PROTECT ALL BUILDING AND PIT WALLS
BELOW GRADE FROM LATERAL LOADS UNTIL ATTACHED FLOORS ARE COMPLETELY IN
PLACE AND HAVE ATTAINED FULL STRENGTH. CONTRACTOR SHALL PROVIDE FOR
DESIGN, PERMITS, AND INSTALLATION OF SUCH BRACING.
2.
3.
4.
5.
6.
FOUNDATIONS SHALL BE PLACED AND ESTIMATED ACCORDING TO DEPTHS SHOWN ON
DRAWINGS. SOIL ENCOUNTERED AT THESE DEPTHS SHALL BE APPROVED BY
THE CONTRACTING OFFICER.
FOOTING BACKFILL AND UTILITY TRENCH BACKFILL WITHIN BUILDING AREA SHALL BE
MECHANICALLY COMPACTED IN LAYERS IN ACCORDANCE WITH THE SOILS REPORT
AND APPROVED BY THE INSPECTOR.
ALL ABANDONED UTILITIES, ETC. SHALL BE REMOVED. NEW FOOTINGS
MUST EXTEND INTO UNDISTURBED SOILS.
SLABS ON GRADE SHALL BE SUPPORTED ON NATURAL GRADE OR COMPACTED
FILL PER THE RECOMMENDATIONS OF THE GEOTECHNICAL REPORT.
8.
9.
10.
11.
SUBGRADE PREPARATION AND FILL REQUIREMENTS:
SEE CIVIL DOCUMENTS
7.
NO. DATE BY DESCRIPTION
DATE
PROJECT NO.
MERRICK PROJECT NO.
DESIGNER
DRAWN BY
PROJECT MANAGER
REAL PROPERTY
SAFETY & HEALTH
PPM
EPM
REVISIONS
OF
SHEET
A-E FIRM USDA
B. THOMPSON
64019314
AG-6395-C-16-0118 ENGINEERING SERVICES BRANCH
4700 RIVER ROAD
RIVERDALE, MD 20737
P
I H
A Animal and Plant Health Inspection Service
S
A. MAGINNIS
A. MAGINNIS
02-16-18
S-001
CONTAINMENT LAB BUILDING 1398 - PHASE
3A & 3B
100% SUBMITTAL
NOT FOR CONSTRUCTION
GENERAL NOTES AND
ABBREVIATIONS
02/16/18
04/20/2018
WITH E70XX ELECTRODES.
PRIOR TO FOUNDATION INSPECTION BY THE SPECIAL INSPECTOR AND OBSERVATION
BY THE CONTRACTING OFFICER REPRESENTATIVE. COAT ANCHOR BOLTS OTHER
THAN STAINLESS STEEL WITH A RUST INHIBITOR.
FOOTING OR COLUMNS UNLESS SPECIFICALLY DETAILED.
ADMIXTURES: REVIEWED BY CONTRACTING OFFICER REPRESENTATIVE, NO CALCIUM CHLORIDE.
THOROUGHLY CLEAN ALL CONCRETE SURFACES TO RECEIVE NEW CONCRETE.
LOCATION OF JOINTS SHALL BE REVIEWED BY THE CONTRACTING OFFICER
ACTUAL DIMENSIONS: SLAB, WALL, BEAM AND COLUMN DIMENSIONS SHOWN ARE
ACTUAL DIMENSIONS NOT NOMINAL DIMENSIONS (i.e. A 4 INCH SLAB IS 4 INCHES
THICK, NOT 3-1/2 INCHES.)
CONCRETE CURING: SEE SPECIFICATIONS.
WELDED REINFORCEMENT: ASTM A-706, CERTIFIED WELDERS. WELD PER AWS D1.4
PIPES, SLEEVES AND DUCTS: SHALL NOT BE PLACED IN WALLS, BEAMS, SLABS,
CHAMFER: 3/4 INCH ON EXPOSED CORNERS.
CONSTRUCTION JOINTS: HEAVY SANDBLAST (1/4 INCH AMPLITUDE MINIMUM) AND
I)
ANCHOR BOLTS, DOWELS AND HOLD-DOWN ANCHORS: SECURELY HELD IN PLACE7.
8.
9.
10.
11.
13.
14.
PLANE JOINTS NOT SPECIFICALLY INDICATED ON THE DRAWINGS SHALL BE REVIEWED
BY THE CONTRACTING OFFICER REPRESENTATIVE PRIOR TO THE PLACING OF REINFORCEMENT.
SLAB-ON-GRADE JOINTS: LOCATION OF ALL CONSTRUCTION, CONTROL AND WEAKENED12.
REPRESENTATIVE. WAIT 48 HOURS BETWEEN POURS.
CORNER OF RECTANGULAR HOLES IN SLABS. PLACE BARS DIAGONALLY.
SLAB CORNERS: PROVIDE (2)-#4 X 4'-0" AT RE-ENTRANT CORNERS AND EACHH)
THE SAME SIZE AND SPACING OF REINFORCEMENT AS SHOWN ON THE DRAWINGS
AND IN THE GENERAL NOTES.
COLUMN BEAM SHALL EXTEND TO WITHIN 2" OF THE FACE AND HAVE A 90 DEGREE
HOOK UNLESS OTHERWISE SHOWN.
REINFORCING BARS BUNDLED IN CONTACT TO ACT AS A UNIT IN A LAYER SHALL
NOT BE LESS THAN 1-1/2 TIMES THE NOMINAL DIAMETER OF THE REINFORCEMENT
OR 1-1/3 TIMES MAXIMUM SIZE AGGREGATE, NOR LESS THAN 1-1/2". NORMAL
DIAMETER FOR A UNIT OF BUNDLED BARS SHALL BE THE EQUIVALENT DIAMETER
OF THE COMBINED AREAS OF THE BARS BUNDLED.
CHAIRS, SPACERS AND SAND PLATES: AS REQUIRED TO MAINTAIN CONCRETE
VERTICAL REINFORCEMENT: SHALL BE DOWELED TO SUPPORTING MEMBERS WITH
HORIZONTAL REINFORCEMENT: ALL BARS ENDING AT THE FACE OF A WALL,
SPACING: CLEAR DISTANCE BETWEEN PARALLEL REINFORCEMENT OR PARALLEL
TACK WELDING, WELDING, HEATING OR CUTTING OF BARS: NOT PERMITTED U.N.O.
C)
D)
E)
F)
G)
315 AND ACI 318. SHOP DRAWINGS REVIEWED BY THE CONTRACTING
OFFICER BEFORE FABRICATION.
MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCEMENT:
MIN. COVER,
INCHES
CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH
CONCRETE EXPOSED TO EARTH OR WEATHER:
NO. 6 THROUGH NO. 18 BAR
NO. 5 BAR, W31 OR D31 WIRE AND SMALLER
CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH
GROUND:
SLABS, WALLS, JOISTS:
NO. 14 AND NO. 18 BAR
NO. 11 BAR AND SMALLER
BEAMS, COLUMNS:
PRIMARY REINFORCEMENT TIES:
REINFORCEMENT:
CAST-IN-PLACE CONCRETE (NON-PRESTRESSED). THE FOLLOWING
STIRRUPS, SPIRALS
6.
A) SHOP DRAWINGS, FABRICATION AND PLACING: SHALL CONFORM TO ACI
B)
1 1/2
1 1/2 3/4
1 1/2
COVER.
ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, MAY BE
INCORPORATED IN THE CONCRETE DESIGN MIXES. A HIGH-RANGE WATER-REDUCING
(HRWR) ADMIXTURE CONFORMING ASTM C494, TYPE F OR G, MAY BE USED IN CONCRETE
MIXES PROVIDING THAT SLUMP DOES NOT EXCEED 9". AN AIR-ENTRAINING AGENT
CONFORMING TO ASTM C260 SHALL BE USED IN CONCRETE MIXES FOR THE EXTERIOR
A WATER-REDUCING ADMIXTURE CONFORMING TO ASTM C494, USED IN STRICT
SURFACES EXPOSED TO COLD WEATHER. THE AMOUNT OF ENTRAINED AIR SHALL BE
5.
6% ± 1% BY VOLUME.
CEMENT
AGGREGATE
REINFORCEMENT
ASTM A - 706
ANCHOR BOLTS
ASTM F - 1554
THE CONCRETE STRENGTHS SHOWN IN THE FOLLOWING TABLE ARE THE MINIMUM
COMPRESSIVE STRENGTHS AT 28 DAYS AND THE WATER/CEMENT RATIO IS THE
MAXIMUM. THE SPECIFIED SLUMP IS THE MAXIMUM PRIOR TO THE ADDITION OF
ADMIXTURES. CONCRETE SHALL BE STANDARD WEIGHT CONCRETE (145 PCF).
ITEM OF
CONSTRUCTION
FOUNDATIONS/GRADE WALLS
MINIMUM OF SEVENTY PERCENT OF THE SPECIFIED 28-DAY STRENGTH FOR ANY
CONCRETE CONSTRUCTION REQUIRING SHORING, BRACING OR TO RECEIVE
MATERIALS:
CONCRETE STRENGTHS:
CONTINUOUS SPECIAL INSPECTION IS REQUIRED FOR DESIGN STRENGTHS EXCEEDING.
CONCRETE SHALL BE PROPORTIONED SUCH THAT 7-DAY STRENGTHS ARE A
REINFORCED CONCRETE
1.
2.
3.
4.
ASTM C - 150
ASTM C - 33
ASTM A - 615
REINFORCEMENT
ASTM A - 36
ANCHOR BOLTS
STRENGTH AGG SLUMP WATER/CEMENT
(PSI) (IN) (IN) (LB/LB)
4,000 1 4 0.57
SLABS-ON-GRADE........................... 4,000 1 4 0.57
2,500 PSI.
CONSTRUCTION LOADS.
GRADE 60 WELDED
HEADED ANCHOR BOLTS
TYPE I I
CRUSHED ROCK
GRADE 60 TYPICAL
HOOKED ANCHOR BOLTS
WIND LOADING SCHEDULE
PER ASCE 7-10
COMPONENTS AND CLADDING
W
AL
L S
UR
FA
CE
S
0 f t
AR
EA
ft
AR
EA
2 4
2 4
SURFACE
RO
OF
S
UR
FA
CE
S
EFFECTIVE
WIND AREA
1 -42.7
P (psf)ZONE
-42.4 39.1 -52.1 39.1 -32.6 29.3 -32.6 29.3
17.4 -71.7 17.4
-107.9 17.4 -39.1 13.8 -46.3 13.8
AR
EA
0 f t
AR
EA
ft
3 -46.3 13.8
TYP AT
ROOF EDGES
TYP AT ROOF
CORNERS
TYP AT
ROOF U.N.O.
TYP AT
ROOF EDGES
a (TYP)
TYP.
a
TYP AT ROOF
CORNERS
TYP AT
ROOF EDGES
TYP AT
WALL U.N.O.
TYP AT WALL
CORNERS
TYP AT WALL
CORNERS
TYP AT
WALL U.N.O.
TYP AT
ROOF EDGES
TYP
NO. DATE BY DESCRIPTION
DATE
PROJECT NO.
MERRICK PROJECT NO.
DESIGNER
DRAWN BY
PROJECT MANAGER
REAL PROPERTY
SAFETY & HEALTH
PPM
EPM
REVISIONS
OF
SHEET
A-E FIRM USDA
B. THOMPSON
64019314
AG-6395-C-16-0118 ENGINEERING SERVICES BRANCH
4700 RIVER ROAD
RIVERDALE, MD 20737
P
I H
A Animal and Plant Health Inspection Service
S
A. MAGINNIS
A. MAGINNIS
02-16-18
S-002
CONTAINMENT LAB BUILDING 1398 - PHASE
3A & 3B
100% SUBMITTAL
NOT FOR CONSTRUCTION
GENERAL NOTES SHEET 2
NTSS-002
1 TYPICAL ROOF CORNER
NTSS-002
2 TYPICAL WALL CORNER
1. FABRICATE ALL STEEL DECK FROM STEEL CONFORMING TO THE LATEST EDITION
OF THE "SPECIFICATIONS FOR THE DESIGN OF COLD FORMED STEEL
STRUCTURAL MEMBERS" BY THE AMERICAN IRON AND STEEL INSTITUTE.
PROVIDE FULL PANEL WIDTH SHEETS FOR THE FIRST SHEET OF STEEL DECK
ADJACENT TO, AND PARALLEL TO, WALLS, PERIMETER MEMBERS, OR MEMBERS
IDENTIFIED AS CHORD, COLLECTOR, STRUT, OR DRAG MEMBERS (ON ONE OR
BOTH SIDES AS APPLICABLE).
SPAN DECKING CONTINUOUS OVER AT LEAST THREE (3) SUPPORTS, UNLESS
SPECIFICALLY DETAILED OTHERWISE.
PROVIDE GALVANIZED STEEL ROOF DECK. METAL DECK SHALL BE GALVANIZED
PER G60 = NORMAL STANDARD
FASTEN ALL STEEL DECK TO A CONTINUOUS DECK ANGLE AROUND ENTIRE DECK
PERIMETER. WHERE NO SPECIFIC SUPPORT IS INDICATED, PROVIDE
CONTINUOUS L3x3x1/4 OR EQUIVALENT BENT PLATE AS NECESSARY TO SUPPORT
DECK EDGES.
ATTACH EACH DECKING PANEL TO SUPPORTING MEMBERS AND ADJACENT
PANELS AS INDICATED IN STEEL DECK SCHEDULE SHEET S-601.
BEAR DECKING AT LEAST 2 INCHES AT SUPPORTS. LAP DECKING AT ENDS AT
LEAST 2 INCHES AND CENTER LAPS OVER SUPPORTS. CENTER LAPS OVER ONE
TOP CHORD ANGLE AT OPEN-WEB STEEL JOISTS OR METAL TRUSS TOP CHORD.
SUBMIT COMPLETE METAL DECKING SHOP DRAWINGS TO THE CONTRACTING
OFFICER FOR REVIEW AND APPROVAL. SHOP DRAWINGS SHALL INDICATE ICC ES
REPORT NUMBER, IF APPLICABLE, LOAD/SPAN CAPACITIES AND DIAPHRAGM
CAPACITY.
PROVIDE FLASHING AND CLOSURE PLATES AT ENDS OF ALL UNITS, AROUND
COLUMNS AND ALL PERIMETER LOCATIONS REQUIRING CONCRETE.
2.
3.
4.
5.
6.
STEEL DECK NOTES
1. FABRICATE AND ERECT STRUCTURAL STEEL IN ACCORDANCE WITH THE AISC "MANUAL OF
STEEL CONSTRUCTION", LOAD AND RESISTANCE FACTOR DESIGN, 14TH EDITION.
PROVIDE WIDE FLANGE SHAPES COMPLYING WITH ASTM A992. PROVIDE ALL OTHER
STRUCTURAL STEEL, OTHER THAN TUBES, COMPLYING WITH ASTM A36.
PROVIDE TUBE STEEL (HSS SHAPES) COMPLYING WITH ASTM A500, GRADE B. PROVIDE A CAP
PLATE FOR ALL HSS EXPOSED ENDS EQUAL TO HSS WALL THICKNESS, (UNLESS SPECIFICALLY
NOTED NOT TO BE PROVIDED) ATTACHED WITH CJP ALL AROUND.
PROVIDE BOLTS FOR BEAM CONNECTIONS COMPLYING WITH ASTM A325 WITH A MINIMUM
DIAMETER OF 3/4" UNLESS OTHERWISE NOTED. DESIGN ALL BOLTED CONNECTIONS NOT
DETAILED AS BEARING-TYPE CONNECTIONS, UNLESS SPECIFICALLY NOTED AS SLIP-CRITICAL.
INSTALL WASHERS UNDER NUTS OF ALL FASTENERS.
CONFORM TO THE PROVISIONS OF AWS D1.1, USING E70XX ELECTRODES FOR ALL WELDING.
SHOP CONNECTIONS MAY BE WELDED OR BOLTED UNLESS SPECIFICALLY DETAILED
OTHERWISE. BOLT FIELD CONNECTIONS UNLESS NOTED OTHERWISE.
FOR CONNECTIONS REQUIRING A WELD WHEN NO WELD IS SHOWN, PROVIDE WELD ALL
AROUND WITH THE MAXIMUM FILLET WELD SIZE ALLOWED BY AWS D1.1 FOR THE CONNECTED
PARTS. PROVIDE WELD EITHER IN THE SHOP OR FIELD, WHICHEVER IS MOST APPROPRIATE.
THE CONTRACTOR IS RESPONSIBLE FOR CHECKING THE CONTRACT DOCUMENTS FOR ALL
MISCELLANEOUS STEEL.
PROVIDE PERIMETER DECK ANGLE AROUND ENTIRE PERIMETER OF STEEL DECK. WELD
CORNERS OF PERIMETER DECK ANGLE.
NON-STRUCTURAL STEEL ELEMENTS INCLUDING STEEL DECK, CONCRETE SLABS, WALLS AND
COLUMNS ARE EMPLOYED TO INTERACT WITH THE STEEL FRAMING TO PROVIDE STABILITY AND
BRACING TO THE OVERALL STRUCTURE. THE STEEL ERECTOR SHALL FURNISH AND INSTALL
ALL NECESSARY TEMPORARY SUPPORTS AND BRACING REQUIRED FOR THE STRUCTURAL
STEEL FRAMING IN ACCORDANCE WITH SECTION 7.10 OF THE AISC CODE OF STANDARD
PRACTICE FOR STEEL BUILDINGS AND BRIDGES. ALL TEMPORARY SUPPORTS AND BRACING
SHALL NOT BE REMOVED OR MODIFIED UNTIL THE SUPPORTING STEEL DECK, CONCRETE
SLABS, WALLS AND COLUMNS, MASONRY WALLS AND COLUMNS ARE COMPLETELY INSTALLED
AND HAVE ACHIEVED THEIR DESIGN STRENGTH.
2.
3.
4.
5.
6.
7.
8.
9.
STRUCTURAL STEEL NOTES
1. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS PRIOR TO
COMMENCING WORK.
IF EXISTING CONDITIONS DO NOT MATCH WHAT IS SHOWN ON THE
STRUCTURAL DRAWINGS, THIS MUST BE BROUGHT TO THE ATTENTION OF
THE STRUCTURAL ENGINEER OF RECORD BEFORE COMMENCING WORK.
CONTRACTOR IS RESPONSIBLE FOR ADDING SHORING PLATES OR BEAMS AS
NECESSARY TO FACILITATE THE REMOVAL OF EXISTING MASORY AND
INSTALLATION OF NEW COLUMNS AND BEAMS.
2.
EXISTING CONDITIONS
10.
VENEER LINTELS:
OPENING WIDTH
UP TO 4'-0"
TYPICAL VENEER LINTEL SCHEDULE
ANGLE LINTEL
NOTES:
1. LINTELS APPLY AT ALL VENEER OPENINGS, UNO.
2. LINTELS SHALL BE PROVIDED FOR MECHANICAL, AS WELL AS
ARCHITECTURAL OPENINGS.
3. EXTEND LINTEL ANGLES 8" BEYOND BRICK OPENING EACH END TO BEAR
ON BRICK BEYOND.
4. FOR ALL OTHER NON-VENEER OPENINGS, SEE DETAIL SHEETS.
3.
7.
8.
9.
1. THE STRUCTURAL SHOP DRAWING REVIEW IS INTENDED TO HELP THE ENGINEER
VERIFY HIS DESIGN CONCEPT. IT IS THE CONTRACTOR'S RESPONSIBILITY TO
CHECK HIS OWN SHOP DRAWINGS.
THE STRUCTURAL SHOP DRAWINGS WILL BE RETURNED FOR RESUBMITTAL IF A
CURSORY REVIEW SHOWS MAJOR ERRORS WHICH SHOULD HAVE BEEN FOUND
BY THE CONTRACTOR'S CHECKING.
THE FOLLOWING SHOP DRAWINGS AND CALCULATIONS, WHEN APPLICABLE ARE
REQUIRED, BUT NOT LIMITED TO, FOR SUBMITTAL FOR STRUCTURAL REVIEW:
A. CONCRETE MIX DESIGNS
B. REINFORCING STEEL
C. STRUCTURAL STEEL AND DECK
D. WELDING PROCEDURE SPECIFICATIONS (WPS)
E. MISCELLANEOUS STRUCTURAL STEEL SHOWN ON STRUCTURAL DRAWINGS
F. PRE-MANUFACTURED COLD-FORMED METAL TRUSSES
G. CURTAIN WALLS
H. CONSTRUCTION JOINT LOCATIONS
ANY SUBMITTAL OF A DETAIL SHEET WITH ADDED INFORMATION SHALL BE
ACCOMPANIED BY A LOCATION PLAN IDENTIFYING THE MEMBERS INVOLVED AND
CLOUDING AROUND ADDED INFORMATION.
ANY ENGINEERING SUBMITTED FOR REVIEW SHALL BE APPROPRIATELY SEALED.
FULL RESPONSIBILITY OF SUCH ENGINEERING RESTS WITH THE PERSON
SEALING THE DESIGN.
2.
SHOP DRAWING SUBMITTALS
3.
4'-1" TO 6'-0"
6'-1" TO 8'-0"
L4x4x5/16
L6x4x5/16 (LLV)
L7x4x3/8 (LLV)
11.
4.
5.
CR
CR
A B C D E
S-103
(30 LOCATIONS)
1' - 9"
4' - 0"
F1
F1
F1
F1
7'
- 6
7'
- 6
7'
- 6
7'
- 3
4'
- 0
F1
F1
F1F1F1F1
F1
F1
F1
F1
F1
4' - 0" 6' - 8" 6' - 8" 6' - 8" 6' - 8"
F2 F2
4'
- 1
3/
4"
5' - 6" 1' - 4"
1'
- 6
ERU PAD
ERU PAD
CONDENSING
PADS
DESIGNATES 5'-4"x2'-0"x1'-0" THICK
FOOTING W/ (3) #5 LONG BARS & (6) #5
TRANSVERSE BARS, BOTTOM, TYP.
WHERE FOOTING IS TO BE PLACED,
REMOVE ASPHALT TO SOIL. COMPACT
SOIL AND PLACE FOOTING ON TOP OF
COMPACTED SOIL.
DESIGNATES 6'-3"x2'-0"x1'-0" THICK
FOOTING W/ (3) #5 LONG BARS & (7) #5
TRANSVERSE BARS, BOTTOM, TYP.
WHERE FOOTING IS TO BE PLACED,
REMOVE ASPHALT TO SOIL. COMPACT
SOIL AND PLACE FOOTING ON TOP OF
COMPACTED SOIL.
LEGEND
F1
F2
KEY PLAN
NOT TO SCALE
NO. DATE BY DESCRIPTION
DATE
PROJECT NO.
MERRICK PROJECT NO.
DESIGNER
DRAWN BY
PROJECT MANAGER
REAL PROPERTY
SAFETY & HEALTH
PPM
EPM
REVISIONS
OF
SHEET
A-E FIRM USDA
B. THOMPSON
64019314
AG-6395-C-16-0118 ENGINEERING SERVICES BRANCH
4700 RIVER ROAD
RIVERDALE, MD 20737
P
I H
A Animal and Plant Health Inspection Service
S
A. MAGINNIS
A. MAGINNIS
02-16-18
S-101
CONTAINMENT LAB BUILDING 1398 - PHASE
3A & 3B
100% SUBMITTAL
NOT FOR CONSTRUCTION
PARTIAL FOUNDATION PLAN
1/8" = 1'-0"1 PARTIAL FOUNDATION PLAN
8 6 4 2 0 8 16
SHEET NOTES:
1.
2.
FIELD VERIFY ALL EXISTING CONDITIONS
AND DIMENSIONS.
CONTRACTOR IS RESPONSIBLE FOR
ADDING SHORING PLATES OR BEAMS AS
NECESSARY TO FACILITATE THE REMOVAL
OF EXISTING MASONRY AND INSTALLATION
OF NEW MEMBERS.
KEYNOTES:
NEW GREENHOUSE WINDOW1
NEW DUCT SUPPORT POSTS: HSS5x5x1/4 POSTS WITH 1'-1"x1'-1"x3/4" BASE PLATE
WITH (4) 3/4" DIA. ANCHOR BOLTS WITH 10"
EMBED. ANCHOR INTO NEW FOOTING; TOP
OF POSTS EL = 10'-0" (VERIFY WITH
MECHANICAL DRAWING AND CONTRACTOR).
NEW PLATFORM POSTS: HSS5x5x1/4 POSTS WITH 1'-1"x1'-1"x3/4" BASE PLATE WITH (4)
3/4" DIA. ANCHOR BOLTS WITH 10" EMBED.
ANCHOR INTO NEW FOOTING; TOP OF
POSTS EL = 9'-5".
D E F G H J K L M N
20' - 0"
S-502
S-502
1/8" = 1'-0"1 PARTIAL ROOF STRUCTURAL PLAN
SHEET NOTES:
1. FIELD VERIFY ALL EXISTING CONDITIONS
AND DIMENSIONS.
KEYNOTES:
MOVEABLE PARTITION ALONG COLUMN LINE
N BETWEEN COLUMN LINES 2 AND 4 IN
CONFERENCE ROOM (BELOW ROOF). SEE
7/S-502.
NEW ANGLE MEMBER TO ATTACH TO
EXISTING ROOF FRAMING MEMBERS TO
SUPPORT EYEBOLT. CONTRACTOR TO
COORDINATE EXACT LOCATION WITH
EQUIPMENT LOCATION. SEE 8/S-502.
8 6 4 2 0 8 16
KEY PLAN
NOT TO SCALE
NO. DATE BY DESCRIPTION
DATE
PROJECT NO.
MERRICK PROJECT NO.
DESIGNER
DRAWN BY
PROJECT MANAGER
REAL PROPERTY
SAFETY & HEALTH
PPM
EPM
REVISIONS
OF
SHEET
A-E FIRM USDA
B. THOMPSON
64019314
AG-6395-C-16-0118 ENGINEERING SERVICES BRANCH
4700 RIVER ROAD
RIVERDALE, MD 20737
P
I H
A Animal and Plant Health Inspection Service
S
A. MAGINNIS
A. MAGINNIS
02-16-18
S-102
CONTAINMENT LAB BUILDING 1398 - PHASE
3A & 3B
100% SUBMITTAL
NOT FOR CONSTRUCTION
PARTIAL ROOF FRAMING PLAN
02/18/16
A B
EXISTING W6
COLUMN
EXISTING W6 COLUMN
EXISTING W6 COLUMN
HSS8X6X5/16
HSS8X6X5/16
HS
S8
X6 X5
/1
HS
S8
X6 X5
/1
19' - 0 1/2"
/2
HSS8X6X5/16
7 1/2"
1' - 10"
2'
- 6
1/
2"
EXISTING W6 COLUMN
HSS8X6X5/16
NOTE: TOP OF STEEL EL. = 102'-6" UNO
HSS8X6X5/16
HS
S8
X6 X5
/1
HS
S8
X6 X5
/1
S-502
S-502
S-502
S-502
HSS8X6X5/16
SEE NOTE 2
SEE NOTE 2
8"
5' - 0 1/2" 8"
S-501
S-501
S-502
A B
EXISTING W6
COLUMN
EXISTING W6 COLUMN
EXISTING W6 COLUMN
19' - 0 1/2"
EXISTING W6 COLUMN
HS
S1
0X 6X
5/
HSS8X6X5/16 LLV LINTEL
LL
V
LI
NT
EL
NEW GREENHOUSE
WINDOW. SEE ARCH. DWGS
(TOS EL. 112'-0" UNO)
(T O
S
EL
. 1
'-0 " U
NO
NEW LINTEL TO BEAR
MIN. 8" ON EXISTING
MASONRY WALL
NEW LINTEL TO BEAR
MIN. 8" ON EXISTING
MASONRY WALL
NO. DATE BY DESCRIPTION
DATE
PROJECT NO.
MERRICK PROJECT NO.
DESIGNER
DRAWN BY
PROJECT MANAGER
REAL PROPERTY
SAFETY & HEALTH
PPM
EPM
REVISIONS
OF
SHEET
A-E FIRM USDA
B. THOMPSON
64019314
AG-6395-C-16-0118 ENGINEERING SERVICES BRANCH
4700 RIVER ROAD
RIVERDALE, MD 20737
P
I H
A Animal and Plant Health Inspection Service
S
C. TRAN
C. TRAN
02-16-18
S-103
CONTAINMENT LAB BUILDING 1398 - PHASE
3A & 3B
100% SUBMITTAL
NOT FOR CONSTRUCTION
PARTIAL WINDOW FRAMING PLAN
1/2" = 1'-0"1 PARTIAL GREENHOUSE FRAMING & FOUNDATION PLAN
SHEET NOTES:
FIELD VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS.
DEMOLISH EXISTING CONCRETE AND MASONRY
STEM WALL AT NEW GREENHOUSE WINDOW AND
ADD NEW CONCRETE STEM WALL PER SECTIONS
2/S-502 & 7/S-501.
CONTRACTOR IS RESPONSIBLE FOR SHORING AS
NECESSARY TO FACILITATE THE REMOVAL OF
EXISTING CONCRETE AND MASONRY WALL AND
INSTALLATION OF NEW MEMBERS.
1/2" = 1'-0"2 PARTIAL GREENHOUSE WINDOW LINTEL PLAN
1.
2.
3.
2 1 0 2 4 2 1 0 2 4
A B C D
19' - 0 1/2" 20' - 0" 20' - 0"
LIGHTGAGE STEEL JOISTS AT 2'-0" O.C.
LI
G
HT
G
AG
E
ST
EE
L
JO
IS
TS
A T
2'- 0"
O .C
LIGHTGAGE STEEL JOISTS AT 2'-0" O.C.
4' - 0"
1' - 9"
(30 LOCATIONS)
C7 1/4 C7 1/4 C7 1/4 C7 1/4 C7 1/4 C7 1/4 C7 1/4 C7 1/4 C7 1/4
C7 1/4 C7 1/4 C7 1/4 C7 1/4 C7 1/4 C7 1/4 C7 1/4 C7 1/4 C7 1/4 C7 1/4
C7 1/4 C7 1/4 C7 1/4 C7 1/4 C7 1/4
C7 1/4 C7 1/4 C7 1/4 C7 1/4 C7 1/4 C7 1/4
C7 1/4 C7 1/4 C7 1/4 C7 1/4
C7 1/4 C7 1/4 C7 1/4
C7 1/4 C7 1/4
3'
- 7
/2
3'
- 9
3'
- 9
3'
- 9
4'
- 0
7'
- 3
7'
- 6
7'
- 6
7'
- 6
4' - 0"
3'
- 9
3'
- 9
3'
- 9
3'
- 7
/2
3' - 4"
4' - 0" 6' - 8"
3' - 4"
6' - 8" 6' - 8"
3' - 4"
6' - 8"
3' - 4"
1' - 3"
4" 4"
W8x18
3/
4" 2'
- 6
2'
- 5
/4
1/ 2"
5' - 6"11' - 10 1/2"
4 POSTS (4 LOCATIONS)
C1
C12
INDICATES DIRECTION OF SPAN OF 1.0",
TYPE "E", 22 GAGE METAL DECK BEARING
ON LIGHT GAGE STEEL JOISTS.
LEGEND
INDICATES MOMENT CONNECTION
INDICATES DIRECTION OF SPAN OF 1"x1/8"
WELDED BAR GRATING, GALVANIZED HOT
DIPPED, GW 100A SMOOTH. BEARING BARS
1 3/16" ON CENTER, REGULAR CROSS BARS
4" ON CENTER. TOP OF GRATING EL. =9'-6".
INTERIOR WALL FRAMING SUPPORTING PLATFORM SHALL BE 400S200-54
MIL STUDS AT 24" O.C. MAX. HEADERS SHALL BE 400S200-54 FOR MAX
OPENING MAX WIDTH OF 4'-0".
REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL DIMENSIONS.
PLATFORM JOISTS SHALL BE C12= 12TDW14 (12" DEEP, TYPE "TDW", 14
GAGE) UNO.
C 7 1/4= 7.25TDJ18 (7.25" DEEP, TYPE "TDJ", 18 GAGE JOISTS) @ 24" O.C.
BOTTOM OF JOISTS EL.=8'-6 5/8"
METAL DECK SHALL BE PLACED ON AREAS WITH 12" JOISTS. NO METAL
DECK SHALL BE PLACED ON 7.25" DEEP JOISTS.
GENERAL FRAMING NOTES
1.
2.
3.
4.
5.
6.
KEY PLAN
NOT TO SCALE
NO. DATE BY DESCRIPTION
DATE
PROJECT NO.
MERRICK PROJECT NO.
DESIGNER
DRAWN BY
PROJECT MANAGER
REAL PROPERTY
SAFETY & HEALTH
PPM
EPM
REVISIONS
OF
SHEET
A-E FIRM USDA
B. THOMPSON
64019314
AG-6395-C-16-0118 ENGINEERING SERVICES BRANCH
4700 RIVER ROAD
RIVERDALE, MD 20737
P
I H
A Animal and Plant Health Inspection Service
S
J. ALDAZ
C. TRAN
02-16-18
S-104
CONTAINMENT LAB BUILDING 1398 - PHASE
3A & 3B
100% SUBMITTAL
NOT FOR CONSTRUCTION
PLATFORM PLAN
1/8" = 1'-0"1 PLATFORM PLAN
8 6 4 2 0 8 16
KEYNOTES:
NEW WINDOW IN EXISTING VENEER SUPPORTED
WITH STRUCTURAL STEEL FRAMING.
NEW HSS5x5x1/4 POSTS TO SUPPORT MECHANICAL
DUCT. TOP OF POSTS EL = 8'-9" (VERIFY WITH
MECHANICAL DRAWING AND CONTRACTOR).
DUCT SUPPORT FRAMING SHALL BE HSS8x6x1/4 (LLV)
UNO. TOP OF DUCT SUPPORT FRAMING EL = 8'-9".
NEW HSS5x5x1/4 POSTS TO SUPPORT EXTERIOR
PLATFORM. TOP OF POSTS EL = 9'-5".
NEW W8x18 BEAMS AT EXTERIOR PLATFORM. TOP OF
STEEL EL. = 9'-5".
DOUBLE WALL STUD (2) 400S200-54.
DOUBLE C12 LIGHT GAGE JOIST. SISTER TOGETHER.
ONE END TO FRAME INTO DOUBLE WALL STUD
SPECIFIED IN KEYNOTE 6; THE OTHER END SHALL
ATTACH TO COLUMN A1.
02/16/1804/20/2018
"D" db
6db*OR3" MIN
135° HOOK
BAR SIZE D'
1 1/2" 2"
2 1/2
#3 #4 #5
"D" db
90° HOOK
* PROVIDE 10db EXTENSIONS IN LIEU OF 6db AT ALL FRAME COLUMNS, GIRDERS, SHEAR WALLS AND SHEAR
WALL BOUNDARY MEMBERS.
TIES & STIRRUPS HOOKS
ONLY
TYPICAL COLUMN
BAR OFFSET"D"
db 12 db
U.
N.
O db
OR 2 1/2"
STANDARD HOOKS
90° HOOK180° HOOK
40 DIA IN MASONRY
30 DIA. IN
CONCRETE
2'-0" MIN. U.N.O.
TYP. COMPRESSION LAP
SPLICE
BAR SIZE D'
6d 8d
10d
#3 THRU #8
#9 THRU #11
#14 THRU #18
4db MIN.
"D
MAX.
4' - 0"
M
AX
4'
- 0
1 1/2" CLR.
(2) #6 BARS AT
T&B OF SLAB,
TYPICAL
(1) #6 BAR AT T&B.
EXTEND TRIMMER
BARS 2'-6" BEYOND
SIDES OF OPENING
OR AS FAR AS
POSSIBLE & HOOK
NOTES:
1. THIS DETAIL APPLIES TO CIRCULAR AND RECTANGULAR
OPENINGS.
2. PROVIDE EXTRA BARS (NOT SHOWN) PARALLEL TO SIDES
OF OPENING EQUAL TO AREA OF INTERRUPTED SLAB
BARS, EXTEND FULL LENGTH OF SPAN.
3. THIS DETAIL IS TYPICAL AT OPENINGS UP TO 4'-0" MAX.
DIMENSIONS UNLESS NOTED OTHERWISE ON PLANS.
2' - 6"
2' - 6"
T.O.C.
EL. = RE: PLAN
CONC. PAD, SEE PLUMBING
MECHANICAL AND
ELECTRICAL DRAWINGS
FOR SIZE AND LOCATION#4 AT
18" O.C.
ROUGHEN SURFACE OF
SLAB BEFORE POURING
PAD
CO
O
RD
IN
AT
E w/ A
RC
H
DW
G
S 4"
A T
HO
US
EK
EE
PI
NG
P
AD
CL
R .2"
6" MIN.
#4 AT 18" O.C.
BENT DOWELS
AN
D
M
EC
H
DW
G S
STEM WALL
OR COLUMN
ENCASEMENT
CONCRETE SLAB
#30 FELT BOND
BREAKER FULL
DEPTH OF
SLAB
(2) #4x4'-0" BARS AT 45
DEGREES TO THE
CORNER
CLR
.2"
2" CUT 50% OF REINF.
ACROSS JOINT. SEE
PLAN FOR REINF. SIZE
FILL WITH SEALANT
CREATE 1/8" WIDE GROOVE BY
TOOLING DURING FINISHING
OPERATIONS.
D
EP
TH
(M
IN
1/ 4"
O F
SL
AB
NEW CONCRETE
STEM WALL
EXISTING FOOTING DRILL AND EPOXY HORIZ
REINF IN NEW STEM
WALL 6 INCHES INTO
EXISTING STEM WALL
DRILL AND EPOXY HORIZ
REINF IN NEW STEM
WALL 6 INCHES INTO
EXISTING STEM WALL
TYPICAL FOUNDATION
REINFORCING
CORNER BAR OF SAME SIZE
AS HORIZONTAL
FOUNDATION REINFORCING,
LAP PER ACI 318.
TYPICAL
FOUNDATION
REINFORCING
4" CONC. SLAB W/
6x6-W2.0xW2.0 WWR
CENTERED IN SLAB FINISHED GRADE
3/4" CHAMFER
(2) #5 BARS CONT.
8"
1'
0"
3" C
LR
REINFORCING DEVELOPMENT
LENGTH SCHEDULE PER ACI 318
REINFORCING SPLICE LENGTH
SCHEDULE PER ACI 318
REINFORCING YIELD STRENGTH, Fy = 60 KSI CONCRETE COMPRESSIVE STRENGTH, f'c = 4,000 PSI
SIZE OF BAR
#6
#10 #11
#8 #9
#7
#3
#5 #4
REQUIRED DEVELOPMENT LENGTH
STRAIGHT BARS
IN.
24.25 26.75
19.00 21.50
16.75
HOOKED BARS
7.25
12.00 14.25
9.50
IN.
REQUIRED SPLICE LENGTH
VERTICAL BARS
#6
#10 #11
#8 #9
#7
SIZE OF BAR
#3
#5 #4
HORIZ. BARS
IN.
IN.
REINFORCING YIELD STRENGTH, Fy = 60 KSI CONCRETE COMPRESSIVE STRENGTH, f'c = 4,000 PSI
MIN. 12 INCH COMPACTED
STRUCTURAL FILL.
REFER TO FOUNDATION
GENERAL NOTES ON S-001.
10 MIL VAPOR BARRIER
REINFORCED CONCRETE
SLAB. SEE FOUNDATION
PLAN FOR THICKNESS &
REINFORCING. ~
#3 AT 12" O.C.,E.W.
(2) #5 CONT.
3/4" CHAMFEREQUIPMENT
ANCHOR BOLTS AND VIBRATION
ISOLATION AS RECOMMENDED BY
EQUIP. MANUFACTURER
1' - 4"
FIN. GRADE
SEE CIVIL
(M
IN
6"
1'
- 6
(MIN.)
1' - 0"
8"
NTSS-501
1 TYPICAL REINFORCING BAR BENDS
NTSS-501
5 REINFORCING AT OPENING IN SLAB
NTSS-501
3 TYP. HOUSEKEEPING PADNTSS-501
2 SLAB REENTRANT CORNER BARS
NTSS-501
4 TYPICAL CONTRACTION JOINT
NO. DATE BY DESCRIPTION
DATE
PROJECT NO.
MERRICK PROJECT NO.
DESIGNER
DRAWN BY
PROJECT MANAGER
REAL PROPERTY
SAFETY & HEALTH
PPM
EPM
REVISIONS
OF
SHEET
A-E FIRM USDA
B. THOMPSON
64019314
AG-6395-C-16-0118 ENGINEERING SERVICES BRANCH
4700 RIVER ROAD
RIVERDALE, MD 20737
P
I H
A Animal and Plant Health Inspection Service
S
A. MAGINNIS
A. MAGINNIS
02-16-18
S-501
CONTAINMENT LAB BUILDING 1398 - PHASE
3A & 3B
100% SUBMITTAL
NOT FOR CONSTRUCTION
TYPICAL CONCRETE DETAILS
NTSS-501
7 NEW STEM WALL ATTACHMENT INTO EXISTING STEM WALL
NTSS-501
TYPICAL FOUNDATION
CORNER REINFORCING
NTSS-501
8 TURNDOWN SLAB
NTSS-501
9 SCHEDULES
NTSS-501
10 TYPICAL EARTHWORK BELOW SLAB
NTSS-501
11 TYPICAL EXTERIOR EQUIPMENT FOUNDATION
t1
HSS BEAM
PER PLAN
HSS BEAM
PER PLAN
t
HSS BEAM
PER PLAN
HSS BEAM
PER PLAN
UNEQUAL DEPTHS
EQUAL DEPTHS
"A" "A"
HSS BEAM TO HSS BEAM
t
A A
HSS COLUMN
HSS BEAM
HSS BEAM TO HSS COLUMN
HSS COLUMN
BEAM WIDTH < COLUMN WIDTH
PLAN
HSS BEAM
1t
HSS BEAM
HSS COLUMN
"A" WELD = SMALLEST TUBE
THICKNESS "t" OR "t " U.N.O.1
BEAM WIDTH = COLUMN WIDTH
PLAN
SECTION A-A
t t t t t t
"A"
"A" "A"
TOP AND
BOTT
"A"
T AND B GRID
SMOOTH
"A"
BOTH SIDES
BOTH SIDES
2' - 1"
EXISTING FOOTING
TO REMAIN
DEMOLISH EXISTING
CONCRETE STEM WALL
BELOW GRADE +
MASONRY WALL ABOVE
GRADE AND REBUILD NEW
CONCRETE STEM WALL
1'-0"x1'-0"x1/2" STEEL
PLATE WITH (4) 3/8" DIA
HILTI HIT-HY200 HAS
RODS W/ 4.5" EMBED.
HSS4x4x1/4" BRACE
NEW 8" CONCRETE
STEM WALL W/ #4@
12" BARS EACH WAY
AT CENTER OF WALL.
DRILL & EPOXY
DOWELS INTO
EXISTING FOOTING.
6" E
M
BE
D.
CURTAINWALL
SYSTEM. SEE ARCH.
1/4 1/4
1/4
1/4 1/4
1/4
7"x7"x1/2" EMBED PLATE
WITH (4) 1/2" HEADED STUDS
x 4" EMBED @ 4" GAGE.
HSS8x6
1/4
3 SIDES
HSS8x6
EXISTING FLOOR SLAB
TOS EL=102'-6"
TOS EL=100'-0"
FI
EL
D
VE
RI
FY
2'
- 1
0" M
IN
4"
3"
NOTE: GUY ANCHOR SHALL BE THALER ARS-300-G (T5) OR APPROVED EQUAL
GALVANIZED FORGED
STEEL EYE (SEE
MANUFACTURER'S
INFORMATION)
18 GA. GALVANIZED
CLOSURE PLATE
SCREW FASTENED
TO STEEL DECK
0°
TENSILE FORCE -660# MAX
90°
EPDM WASHER
EMBED DECK
FLANGE IN
PLASTIC CEMENT
EXISTING OPEN WEB
STEEL JOIST
HSS PIPE (SEE
MANUFACTURER'S
INFORMATION)
ROOFING
3/8" J-BOLT
ANCHOR TO
JOIST
NOTE:
DESIGN IS BASED ON
4'-0" MAX. OPENING
DIMENSION AND A 200
lb LOAD OVER
OPENING. LARGER
OPENINGS OR
HEAVIER LOAD SHALL
BE SUBMITTED TO
STRUCTURAL
ENGINEER FOR
REVIEW
4'-0" MAX.
SP
AC
ED
P
ER
P
LA
N
LIGHT GAUGE
JOIST
7.25TDJ18
LIGHT GAUGE
JOIST
ROOF
DECK SPAN
DIR. REF.
PLAN
SE
E
PL
AN
1/
2"
TY
P.
SEE PLAN
1 1/2"
TYP.
COLUMN BASE PLATE
PER PLAN HEAVY HEX NUT
STANDARD WASHER
GROUT
1 1
/2
1/ 2"
TY
P.
7 4 9/
8"5" PROJECTION
1'- 0"
TACK WELD
(3) PLACE, TYP.
3/4" DIA. ANCHOR
BOLTS
B.O. BASEPLATE
SEE FND. PLANS
FULLY THREADED RODS
ARE NOT PERMITTED
LEVELING NUT
NOTE:
1'
- 2
9/
6"
T.O.C.
EL. = SEE PLAN
(4) 3/4" DIA. ANCHOR BOLTS
STEEL COLUMN
GRID
1/4
3/8"x3"x6" PLATE
(TYP. 2 PLACES)
L1 1/2x1 1/2x3/16 KICKER.
PLACE KICKERS APPROX
AT MIDPOINT OF BEAM. MOVEABLE PARTITION
BRACKET MOUNT (BY
MANUFACTURER)
3/8"4"x4"
TRIANGULAR
STIFFENER
PLATE BOTH
SIDES OF WEBS
NEW W8x31 BEAM TO
SUPPORT MOVEABLE
PARTITION. COORDINATE
WITH ARCH. DRAWINGS AND
PARTITION MANUF.
3/16
TYP. BOTH
SIDES OF
STIFF.
PLATES
3/16
3 SIDES, TYP
AT ALL ENDS
OF KICKERS
3/16
TYP. PLATE
TO BEAM
EXISTING ROOF BEAM
5/16 1@12
EXISTING ROOF FRAMING
STEEL JOISTS OR
STRUCTURAL STEEL BEAMS.
NEW L3x3x1/4 FRAME
BETWEEN EXISTING
ROOF MEMBERS.
NEW 1/2" DIA. LIFTING EYEBOLT WITH
NUT GALVANIZED. 1/4"-20 THREADS, 2"
THREADED LENGTH, 4" SHANK
LENGTH. EYEBOLT MUST BE ABLE TO
SUPPORT CAPACITY OF 250 LBS.
S-502
3/16 3/16
NOTE: LOADING ON EYEBOLT MUST NOT EXCEED 250LBS
L3X3
EYEBOLT
WITH NUT
NO. DATE BY DESCRIPTION
DATE
PROJECT NO.
MERRICK PROJECT NO.
DESIGNER
DRAWN BY
PROJECT MANAGER
REAL PROPERTY
SAFETY & HEALTH
PPM
EPM
REVISIONS
OF
SHEET
A-E FIRM USDA
B. THOMPSON
64019314
AG-6395-C-16-0118 ENGINEERING SERVICES BRANCH
4700 RIVER ROAD
RIVERDALE, MD 20737
P
I H
A Animal and Plant Health Inspection Service
S
C. TRAN
C. TRAN
02-16-18
S-502
CONTAINMENT LAB BUILDING 1398 - PHASE
3A & 3B
100% SUBMITTAL
NOT FOR CONSTRUCTION
TYPICAL STEEL DETAILS
NTSS-502
1 TYPICAL HSS TO HSS DETAIL
NTSS-502
2 SECTION AT GREENHOUSE WINDOW
NTSS-502
3 GUY ANCHOR FOR MECHANICAL STACKS
NTSS-502
4 TYPICAL FRAMING AT DECK MECH OPENING
NTSS-502
TYPICAL ANCHOR BOLTS AND BASE PLATE
AT DUCT SUPPORTS
NTSS-502
6 HSS BEAM TO COLUMN ATTACHMENT DETAIL
NTSS-502
7 MOVEABLE PARTITION BRACKET CONNECTION
NTSS-502
8 EYEBOLT SUSPENSION SYSTEM
NTSS-502
9 SECTION THROUGH EYEBOLT SUPPORT
ABBREVIATIONS:
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RE: REFER TO/REFERENCE/SEE
REINF REINFORCE (D) , (ING)
SC SCALE
SCHED SCHEDULE
SECT SECTION
SHT SHEET
SIM SIMILAR
SPEC SPECIFICATION (S)
SQ SQUARE
SS STAINLESS STEEL
STL STEEL
STRUC STRUCTURAL
TOC TOP OF CONCRETE
TOP TOP OF PAVING
TYP TYPICAL
TOS TOP OF STEEL
UBC UNIFORM BUILDING CODE
UNO UNLESS NOTED OTHERWISE
(V) VERTICAL
VB VAPOR BARRIER
VIF VERIFY IN FIELD
WPR WATERPROOF
WR WATER RESISTANT
WWF WOVEN WIRE FABRIC
W/ WITH
GEN GENERAL
GFGI GOVERNMENT FURNISHED
GOVERNMENT INSTALLED
GL GLASS / GLAZING
GR GRADE
GWB GYPSUM WALL BOARD
GMGB GLASS-MAT GYPSUM BOARD
(H) / HORIZ HORIZONTAL
HB HOSE BIB
HM HOLLOW METAL
HR HOUR
HT HEIGHT
INCL INCLUDE (D) , (ING)
INFO INFORMATION
INSUL INSULATE (ED) , (ION)
INCL INCLUDE (D) , (ING)
INFO INFORMATION
INSUL INSULATE (ED) , (ION)
JST JOIST
JT JOINT
KO KNOCKOUT
LKR (S) LOCKER (S)
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MFR MANUFACTURE (R)
MIN MINIMUM
MISC MISCELLANEOUS
MTL METAL
N NORTH
NIC NOT IN CONTRACT
NO. NUMBER
NTS NOT TO SCALE
OC ON CENTER (S)
OD OUTSIDE DIAMETER
OPNG OPENING
OPP OPPOSITE
PC PRECAST CONCRETE
P.L. PROPERTY LINE
PL PLATE
PLAS PLASTER
PR PAIR
PT POINT
AFF ABOVE FINISH FLOOR
ALT ALTERNATE
ARCH ARCHITECT / ARCHITECTURAL
ASPH ASPHALT
BLDG BUILDING
BM BEAM
BOT BOTTOM
BS BACKSPLASH
CEM CEMENT
CER CONTROLLED ENVIRONMENT
ROOM
CFCI CONTRACTOR FURNISHED
CONTRACTOR INSTALL
CHNL CHANNEL (S)
CIP CAST IN PLACE
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONSTR…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.