The document addresses three key inquiries regarding site visits and material specifications. Contractors are not required to schedule a site visit, as the road to the Elijah Fishing Pier is open and receives no winter maintenance. Regarding lumber materials, while Douglas Fir is the preferred specification due to its longest design life and minimal maintenance requirements, Yellow Pine is acceptable as an alternative if Douglas Fir is not reasonably available. All lumber must be treated with Copper Naphthenate Hydrocarbon Solvent A per AWPA UC4B (minimum) standards. If Yellow Pine is used instead, contractors must substitute the appropriate treatment chemical for Yellow Pine while maintaining the same UC4B treatment use category and retention levels. The treatment specifications remain unchanged regardless of lumber type selected.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Allegheny National Forest

Elijah Fishing Pier Repairs

Questions and Answers as of 1/27/26

1. Can we schedule a site visit? Contractors do not need to schedule a site visit, the road to the Elijah Fishing Pier is open. There is no Winter maintenance on the road.

2. Material notes are requesting a certain type of lumber that is only available on the West coast.

All treated lumber on the East coast is Yellow Pine. Would Yellow Pine be acceptable?

The Douglas Fir has the longest design life and will require the least maintenance.

However, if it is not reasonably available, yellow pine will be acceptable. Note that the treatment requirement does not change.

TREATED WITH COPPER NAPHTHENATE HYDROCARBON SOLVENT A, PER AWPA, UC4B

(MINIMUM).

3. If using Yellow Pine lumber:

Use the appropriate treatment chemical for the yellow pine in lieu of the copper naphthenate Note that the treatment Use Category doesn't change. All material shall be treated to applicable retention levels for Category UC4B (minimum).

File details come from the government source that posted it. Updated .