7Yakutat_Ranger_House_LBP.PDF
PDF 339 KB Posted
- Attached to
- Yakutat Ranger House Remodel
- Solicitation number
- 12010918Q0078
About this file
Attachment #7 - Lead Paint Report for Ranger House
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 12010918Q0078_amend3.pdf | ||
| 12010918Q0078_amend2.pdf | ||
| 8Yakutat_Ranger_House_LBP_XRF_file.xls.csv | CSV file | |
| 12010918Q0078_amend1.pdf | ||
| 5Yakutat_Ranger_House_AsbestosMP.PDF | ||
| 3Modular_Units_Sketches.pdf | ||
| 12010918Q0078.pdf | ||
| 4WageRate_AK180005.pdf | ||
| 1Photos.docx | DOCX document | |
| 6EXPERIENCE_AND_CAPABILITY_QUESTIONNAIR1.docx | DOCX document | |
| 2Floorplan_blg_1021_yakutatRD.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
K E N T & S U L L I V A N, I N C.
25-11/37 Buildings/DRAFT Report.DOC 37 Building Inspections U.S.D.A. Forest Service, Alaska Region
Building 088-R Ranger Residence
Infra #1021, Yakutat
Summary of Findings
� This 1,444 sf house was reportedly built in 1964, and it is in good condition.
� Lead-based paint. A total of 94 XRF measurements were collected, and 12 readings were over
1.0 mg/cm2. Exterior door and window frames (green and white) ranged from 2.0 to 30 mg/cm2.
Four white interior doors and door frames and one white closet shelf ranged from 2.1 to 2.7 mg/cm2. A white cabinet door in the bathroom was 5.4 mg/cm2. Two locations of the textured white ceiling were 1.5 and 1.7 mg/cm2.
� Asbestos. An asbestos inspection was not specified for this building.
� PCB-containing light ballasts. None.
� Fluorescent light bulbs. None.
� Floor drains. None.
� Fuel storage tanks. An AST with secondary containment was located behind the building. The condition of the tank appeared to be fair condition (some rust on the top and sides). Evidence of spills or soil staining were not observed.
� Significant mold. None.
� Other hazardous building materials. Four smoke detectors containing Am-241 and one mercury thermostat and were inventoried.
File details come from the government source that posted it.