7Yakutat_Ranger_House_LBP.PDF

PDF 339 KB Posted

Attached to
Yakutat Ranger House Remodel
Solicitation number
12010918Q0078
Issued by

About this file

Attachment #7 - Lead Paint Report for Ranger House

View the file

Other files

File Type Posted
12010918Q0078_amend3.pdf PDF
12010918Q0078_amend2.pdf PDF
8Yakutat_Ranger_House_LBP_XRF_file.xls.csv CSV file
12010918Q0078_amend1.pdf PDF
5Yakutat_Ranger_House_AsbestosMP.PDF PDF
3Modular_Units_Sketches.pdf PDF
12010918Q0078.pdf PDF
4WageRate_AK180005.pdf PDF
1Photos.docx DOCX document
6EXPERIENCE_AND_CAPABILITY_QUESTIONNAIR1.docx DOCX document
2Floorplan_blg_1021_yakutatRD.pdf PDF
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

K E N T & S U L L I V A N, I N C.

25-11/37 Buildings/DRAFT Report.DOC 37 Building Inspections U.S.D.A. Forest Service, Alaska Region

Building 088-R Ranger Residence

Infra #1021, Yakutat

Summary of Findings

� This 1,444 sf house was reportedly built in 1964, and it is in good condition.

� Lead-based paint. A total of 94 XRF measurements were collected, and 12 readings were over

1.0 mg/cm2. Exterior door and window frames (green and white) ranged from 2.0 to 30 mg/cm2.

Four white interior doors and door frames and one white closet shelf ranged from 2.1 to 2.7 mg/cm2. A white cabinet door in the bathroom was 5.4 mg/cm2. Two locations of the textured white ceiling were 1.5 and 1.7 mg/cm2.

� Asbestos. An asbestos inspection was not specified for this building.

� PCB-containing light ballasts. None.

� Fluorescent light bulbs. None.

� Floor drains. None.

� Fuel storage tanks. An AST with secondary containment was located behind the building. The condition of the tank appeared to be fair condition (some rust on the top and sides). Evidence of spills or soil staining were not observed.

� Significant mold. None.

� Other hazardous building materials. Four smoke detectors containing Am-241 and one mercury thermostat and were inventoried.