About this file
The document appears to be a technical data sheet for MG Squared, Inc.'s Lowering Systems HYPIP6 3 Triple Ethernet/IP CAT6 Shielded Connectors, specifically related to Invitation No. 075-26 for Items 3-01, 3-02, and potentially 3-05. The data sheet provides detailed technical specifications for specialized connectors designed for outdoor use within camera lowering devices.
The technical specification details CAT6 shielded connectors with either dual (18 contacts) or single (14 contacts) Ethernet/IP configurations, featuring gold-plated copper alloy contacts measuring 0.09" in diameter. These connectors are designed for network cable applications including Ethernet/IP, data transmission, video transmission, control, and Power over Ethernet (POE). The connectors are constructed with synthetic rubber (Neoprene or Hypalon) bodies, provide waterproof environmental sealing, and are rated for outdoor use. Each connector is tested and verified for data transmission speeds up to 1000BASE-T (1GB/s) and includes additional optional contact leads for ground, alarm, power, and analog connections.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MG Squared, Inc. Lowering Systems
HYPIP6 3
Triple Ethernet/IP CAT6 Shielded Connectors
(Synthetic Molded Rubber Contact Blocks)
Data Sheet
CAT6a Shielded Connectors: MG2 CAT6 Shielded Ethernet/IP connectors are specifically designed for out-door use within the disconnect unit of the MG2 camera lowering device (CLD). The insulating connector bodies are molded from thermosetting synthetic rubber (Neoprene or Hypalon) and all wire leads are fac-tory molded to the respective contact block which provides the ultimate environmental seal even when disconnected and lowered. All current carrying male pin and female socket contacts shall be Copper Alloy and Gold Plated per ASTM-B-488. To ensure pins are not easily bent, each of the gold plated contacts measures 0.09” min. outside diameter.
Connector 1—Dual Ethernet: For proper and complete performance, each Dual Ethernet/IP Male-Female connector shall be equipped with a total of eighteen (18) specifically designed contacts. Eighteen (18)
0.09” diameter gold plated contacts are provided on CAT6 Shielded Industrial Grade Outdoor Rated Net-work Cable, for Ethernet/IP/DATA/Video transmissions/Control/ and POE (Power Over Ethernet) where applicable. Each CAT6 shielded cable is terminated with a shielded RJ-45 male connector.
Connector 2—Single Ethernet: For proper and complete performance, each Single Ethernet/IP Male-
Female connector shall be equipped with a total of fourteen (14) specifically designed contacts. Of the fourteen (14) contacts - Nine (9) 0.09” diameter gold plated contacts are provided on CAT6 Shielded Indus-trial Grade Outdoor Rated Network Cable, for Ethernet/IP/DATA/Video transmissions/Control/ and POE
(Power Over Ethernet) where applicable. The CAT6 shielded cable is terminated with a shielded RJ-45 male connector. In addition there are five (5) 0.09” diameter gold plated contacts to #18/1 AWG, 600V
UL wire leads - bare and numbered 1-5 (for optional ground, alarms, power, analog connections where ap-plicable). All cable jackets shall be outdoor rated.
These Male/Female contacts are permanently and integrally molded in the synthetic rubber body. Each male Pin shall incorporate an “O” Ring type shoulder at the base of each Pin to completely isolate and protect each contact individually from the environmental exposure. The Ethernet contact block and connectors are waterproof and are compatible with all Ethernet and POE Cameras supporting all applicable camera functions. The connectors provide a complete environmental seal when the camera is raised and secured in place. The male and female connector is equipped with a spring-assisted disconnect when mounted in the disconnect head which maintains constant pressure upon the contact bodies. Each con-tact is tested & verified for Ethernet data transmission speeds up to 1000BASE-T (1GB/s).
Version: 240821A