00017614 - Exhibit 6 - Mitchell_Ceiling_Drawings.pdf
PDF 3 MB Posted
- Solicitation number
- S-73000-00017614
- Issued by
- Oregon
About this file
This is an architectural drawing set prepared by Franco Doughton for the Oregon Department of Transportation (ODOT) for ceiling installation work at the Mitchell Maintenance Station Storage Building located at 17655 Highway 26, Mitchell, Oregon 97750. The project involves a 1,728 square foot storage facility (occupancy classification S-1, construction type V-B) and includes installation of a new ceiling with framing, metal panels, attic access, attic ventilation, and related components as the base bid. The drawings, dated January 13, 2004 with revisions through July 13, 2026, provide detailed floor plans, reflected ceiling plans, sections, elevations, and construction details necessary for bidding and construction. The project includes two additive alternates prioritized in numerical order: Add Alternate #1 covers removal of existing building lighting and installation of new lighting fixtures with an occupancy sensor, and Add Alternate #2 involves installation of a new 6-inch thick reinforced concrete floor slab with thickened edge. The drawings specify that contractors must conduct site visits to examine existing conditions prior to bidding and submit any discrepancies through requests for clarification as outlined in the bid documents.
The project notes indicate that ODOT has limited funding available for construction and uses the additive alternates structure to maximize work completion within available funding limits, with individual alternates to be awarded based on funding availability. The contract award will be made as described in the Invitation to Bid Attachment C-Bid Pricing Form. All work must conform to applicable codes, laws, and ordinances of the jurisdiction having authority, with contractors responsible for coordination of concrete test cylinders to verify seven-day and twenty-eight-day concrete strengths in accordance with specifications. The contractor shall provide all labor, materials, and minor components necessary to deliver a complete and functional project, with all installations performed according to manufacturer's published instructions and recommendations. The drawings specify that ceiling installation must be tight with no gaps greater than one-quarter inch and that the entire work area must be cleaned to the satisfaction of the ODOT project manager upon project conclusion.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WALLOWA
UNION
UMATILLA
MORROW
GILLIAM
SHERMANWASCO
HOOD
RIVER
CLACKAMAS
MULTNOMAH
COLUMBIA
CLATSOP
TILLAMOOK
WASHINGTON
YAMHILL
POLK
LINCOLN
BENTON
LINN
MARION
LANE
DOUGLAS
COOS
CURRY
JOSEPHINE
JACKSON
KLAMATH
LAKE
HARNEY
MALHEUR
CROOK
JEFFERSON WHEELER
GRANT
BAKER
DESCHUTES
26 JOHN
DAY
THE
DALLES
PENDLETON
LA
GRANDE
BAKER
CITY
ONTARIO
BURNS
BEND
KLAMATH
FALLS
PORTLAND
SALEM
EUGENE
ROSEBURG
MEDFORD
COOS
BAY
NEWPORT
ASTORIA
FLORENCE
CORVALLIS
ALBANY
ASHLAND
LAKEVIEW
OHP
SAND STOCKPILE
STORAGE
F4350404
PRE-MIX
F4350403
FUEL
F4350402
MAINTENANCE SHOP
F4350401
GRAVEL YARDOCHOCO HIGHWAY 26
PROJECT LOCATION, SEE EXISTING
FLOOR PLAN ON DRAWING A101
REDUCED 50%
WHEN PRINTED
AT 11" x 17"
TH
IS
D R
AW
IN
G
IS
R
ED
U C
ED
IF
B O
R D
ER
IS
N O
T
/2
" x
2"
F4350404
ODOT MITCHELL MAINTENANCE STATION
STORAGE BUILDING CEILING INSTALLATION
17655 HWY 26, MITCHELL, OR 97750 4
04/15/26
FRANCO
JON DOUGHTON S T R U C T U R A L
J A
N U A R Y 1 3 , 2
0 0
ODOT MITCHELL MAINTENANCE STATION
STORAGE BUILDING CEILING
INSTALLATION
17655 HWY 26, MITCHELL, OR 97750
1. ALL WORK SHALL CONFORM TO APPLICABLE CODES, LAWS AND ORDINANCES OF THE
JURISDICTION HAVING AUTHORITY.
2. CONTRACTOR SHALL COORDINATE AND ODOT SHALL PAY FOR CONCRETE TEST CYLINDERS TO
VERIFY 7 DAY AND 28 DAY STRENGTHS OF CONCRETE IN ACCORDANCE WITH SPECIFICATIONS.
3. DO NOT SCALE THE DRAWINGS.
4. CONTRACTOR SHALL MAKE A SITE VISIT AND EXAMINE EXISTING CONDITIONS PRIOR TO
PROVIDING A BID. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF ODOT
THROUGH A REQUEST FOR CLARIFICATION AS SET FORTH IN THE BID DOCUMENTS.
5. CLARIFICATIONS SHALL BE REQUESTED IN WRITING PRIOR TO ANY INSTALLATION. INCORRECT
INSTALLATIONS SHALL BE CORRECTED AT NO ADDITIONAL COST TO ODOT.
6. ALL WORK SHOWN IS TO BE BY THE CONTRACTOR UNLESS SPECIFICALLY NOTED AS BEING BY
ODOT OR BY OTHERS. ALL MATERIALS SHOWN ARE TO BE PROVIDED BY THE CONTRACTOR
UNLESS SPECIFICALLY NOTED AS EXISTING OR PROVIDED BY ODOT.
7. DRAWINGS ARE SCHEMATIC IN NATURE. MAJOR COMPONENTS ARE SHOWN ON THE DRAWINGS.
CONTRACTOR SHALL SUPPLY AND INSTALL ALL MINOR COMPONENTS AND MATERIALS
NECESSARY TO PROVIDE A COMPLETE AND FUNCTIONAL PROJECT WHETHER OR NOT ALL SUCH
COMPONENTS ARE NOTED IN THE DRAWINGS AND SPECIFICATIONS.
8. ALL MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED
INSTALLATION INSTRUCTIONS AND RECOMMENDATIONS.
9. INSTALL CEILING TIGHT WITH NO GAPS GREATER THAN 1/4". INSTALL BLOCKING AS REQUIRED.
10. CLEAN ENTIRE WORK AREA AT CONCLUSION OF PROJECT TO THE SATISFACTION OF THE ODOT
PROJECT MANAGER.
GENERAL CONSTRUCTION NOTES
T101 TITLE SHEET
A101 FLOOR PLAN AND REFLECTED CEILING PLAN
A102 SECTIONS AND ELEVATIONS
A103 DETAILS
SHEET INDEX
STATE VICINITY MAP
SCALE: N.T.S.
TITLE SHEET T101
MITCHELL
0 60'
SITE PLAN
SCALE: 1" = 60''
OCCUPANCY: STORAGE S-1
CONSTRUCTION TYPE: V-B
AREA: 1,728 SF
CODE DATA: ADD ALTERNATES:
AGENCY HAS LIMITED FUNDING AVAILABLE FOR THE CONSTRUCTION OF THIS PROJECT AND THE FUNDING MAY NOT BE ADEQUATE TO CONSTRUCT THE ENTIRE PROJECT. ADDITIVE ALTERNATES ARE BEING USED TO MAXIMIZE THE WORK THAT CAN BE COMPLETED WITHIN THE AVAILABLE FUNDING LIMITS. ADDITIVE ALTERNATE PRIORITIES ARE IN NUMERICAL ORDER FROM #1 THROUGH #2. INDIVIDUAL ALTERNATES WILL BE AWARDED TO MATCH AVAILABLE FUNDING. THE CONTRACT AWARD WILL BE AS DESCRIBED IN THE INVITATION TO
BID ATTACHMENT C-BID PRICING FORM.
BASE BID - INSTALL NEW CEILING IN EXISTING STORAGE BUILDING, ATTIC VENTILATION, AND ATTIC ACCESS AS SHOWN ON DRAWINGS.
ADD ALTERNATE #1 - REMOVE EXISTING BUILDING LIGHTING AND INSTALL NEW LIGHTING AS SHOWN ON DRAWING A101.
NOTE: IF ADD ALTERNATE #1 IS NOT SELECTED BY ODOT, THE REMOVAL OF EXISTING LIGHTING IS BY OTHERS (NOT IN CONTRACT).
ADD ALTERNATE #2 - INSTALL NEW 6" THICK REINFORCED CONCRETE FLOOR SLAB WITH THICKENED EDGE AS SHOWN ON DRAWINGS.
1 06/30/26 NO CHANGE THIS SHEET JD
2 07/13/26 MODIFY ADD ALTERNATES JD
±36'-0"
±48'-0"
TYPICAL NEW 6" THICK
REINFORCED CONCRETE
SLAB (INCLUDED IN ADD
ALTERNATE #2), SEE DETAIL
OPEN STORAGE
TYPICAL CONTROL
JOINT CENTERED ON
POST (INCLUDED IN
ADD ALTERNATE #2),
SEE DETAIL
A103
A103
A103 TYP.
A102
A102
THICKENED EDGE AT OPEN
SIDE (INCLUDED IN ADD
ALTERNATE #2), SEE DETAIL
A103
A103
A103
ATTIC ACCESS IN NEW
CEILING, CENTER ON
RIDGE, SEE DETAIL
A103
A103
A103
A103
A102
A102
A103
TYP.
LINE OF TRUSSES
ABOVE CEILING, TYP.
TYPICAL NEW
CEILING, SEE DETAIL 3
A103
(3) NEW LIGHT FIXTURES IN A
ROW, CENTERED ON TRUSSES,
TYPICAL (3) PLACES
(INCLUDED IN ADD ALTERNATE #1)NEW OCCUPANCY SENSOR
SWITCH MOUNTED ON CEILING
(INCLUDED IN ADD ALTERNATE #1)
TH
IS
D R
AW
IN
G
IS
R
ED
U C
ED
IF
B O
R D
ER
IS
N O
T
/2
" x
2"
F4350404
ODOT MITCHELL MAINTENANCE STATION
STORAGE BUILDING CEILING INSTALLATION
17655 HWY 26, MITCHELL, OR 97750 4
04/15/26
FRANCO
JON DOUGHTON S T R U C T U R A L
J A
N U A R Y 1 3 , 2
0 0
FLOOR PLAN AND REFLECTED CEILING PLAN A101
FLOOR PLAN
SCALE: 1/4" = 1'-0"
REFLECTED CEILING PLAN
SCALE: 1/4" = 1'-0"
REDUCED 50%
WHEN PRINTED
AT 11" x 17"
1 06/30/26 ADD LIGHT FIXTURES AND ELECTRICAL
NOTES
JD
ELECTRICAL NOTES (INCLUDED IN ADD
ALTERNATE #1):
1. ALL ELECTRICAL WORK SHALL BE PERFORMED BY A
LICENSED ELECTRICIAN IN ACCORDANCE WITH
APPLICABLE CODES.
2. BASIS OF DESIGN LIGHT FIXTURE IS LITHONIA
LIGHTING MODEL NUMBER CSS L96 ALO4 MVOLT
SWW3 80 CRI. SET TO MAXIMUM LIGHT OUTPUT AND
3500K COLOR TEMPERATURE. MOUNT TO CEILING IN
APPROXIMATE LOCATION SHOWN.
3. BASIS OF DESIGN OCCUPANCY SENSOR IS LITHONIA
LIGHTING CRM 10. MOUNT TO CEILING IN
APPROXIMATE LOCATION SHOWN TO MAXIMIZE
DETECTION.
4. REMOVE EXISTING LIGHTING AND RETURN TO ODOT.
MODIFY EXISTING ELECTRICAL SYSTEM AS
REQUIRED TO SUPPLY NEW LIGHTING FIXTURES.
PROVIDE OCCUPANCY SENSOR BETWEEN EXISTING
MANUAL SWITCH AND NEW LIGHTING.
5. USE MC CABLE WITH COPPER CONDUCTORS FOR
NEW WIRING RUNS. SEAL PENETRATIONS IN CEILING.
2 07/13/26 INCLUDE ADD ALTERNATE REFERENCES JD
EXISTING METAL
ROOFING
EXISTING ENGINEERED
TRUSS
EXISTING POST
COLUMN
TYPICAL NEW CEILING, APPLY NEW METAL
PANELS TO NEW 2x6 CEILING JOISTS AT 3'-0"
ON CENTER, SEE DETAIL
NEW 6" THICK CONCRETE FROM SLAB
(INCLUDED IN ADD ALTERNATE #2),
SEE DETAIL
THICKENED EDGE, (INCLUDED IN
ADD ALTERNATE #2), SEE DETAIL
A103
A103
A103
A103
A103
OPEN OPEN OPEN OPEN
TWO NEW 2'-6"x2'-6" LOUVERS AT EACH
END OF BUILDING, POSITION TO FIT
BETWEEN TRUSS WEBS, TYP.
A103 TYP.
TH
IS
D R
AW
IN
G
IS
R
ED
U C
ED
IF
B O
R D
ER
IS
N O
T
/2
" x
2"
F4350404
ODOT MITCHELL MAINTENANCE STATION
STORAGE BUILDING CEILING INSTALLATION
17655 HWY 26, MITCHELL, OR 97750 4
04/15/26
FRANCO
JON DOUGHTON S T R U C T U R A L
J A
N U A R Y 1 3 , 2
0 0
SECTIONS AND ELEVATIONS A102
EXISTING BUILDING SECTION
SCALE: 3/8" = 1'-0"
A102
PROPOSED BUILDING SECTION
SCALE: 3/8" = 1'-0"
A102
NORTH ELEVATION
SCALE: 1/8" = 1'-0"
SOUTH ELEVATION
SCALE: 1/8" = 1'-0"
EXISTING EAST / WEST ELEVATION
SCALE: 1/8" = 1'-0"
PROPOSED EAST / WEST ELEVATION
SCALE: 1/8" = 1'-0"
REDUCED 50%
WHEN PRINTED
AT 11" x 17"
1 06/30/26 NO CHANGE THIS SHEET JD
1-1/2" DEEP SAW CUT
CONTROL JOINT WHERE
SHOWN ON PLAN
6"
EXIST. BASE
COMPACT EXISTING CRUSHED
AGGREGATE IN-PLACE UNDISTURBED SOIL
VAPOR RETARDER
#4 REINFORCING BARS AT
18" ON CENTER EACH WAY,
2" CLEAR OF TOP OF SLAB
1'-0"
1'-0"1"
1'-0"
UNDISTURBED
EXISTING BASE
TYPICAL SLAB,
SEE DETAIL
A103
NEW 3/4" MINUS COMPACTED
CRUSHED AGGREGATE ROCK
WEDGE 5'-0" WIDE
(2) #4 BARS
CONTINUOUS
METAL CEILING PANEL IS TO BE 29 GAUGE
WITH A NOMINAL WIDTH OF 3 FEET.
FASTENERS ARE TO BE #10 x 1 1/2" SCREWS
WITH NEOPRENE AND COLOR MATCHED
WASHERS. PLACE FASTENERS NEXT TO
MAJOR RIBS AT 9" ON CENTER.
29 GAUGE METAL PANEL
#10 x 1 1/2" SCREWS AT 9" ON
CENTER ALONG EACH JOIST
INSTALL SCREW THROUGH BOTH
SHEETS AT JOINT, TYPICAL
EXTENDED LEG
ON SHEET
SHEET OVERLAP #14 x 3/4" STITCH SCREWS
AT 24" ON CENTER
NEW 2x6 CEILING JOIST
AT 3'-0" ON CENTER
PRE-FINISHED METAL "J" CHANNEL
EDGE TRIM AROUND OPENING, TYP.
TYPICAL 2x2 PERIMETER
WITH 1/4" GAP TO FRAMING
NEW 1/2" THICK 5-PLY ACX
PLYWOOD ACCESS PANEL
#9x1-1/2" SCREWS AT 6"
ON CENTER AROUND
PERIMETER
TYPICAL 2x6
PERIMETER FRAMING
NEW PRE-FINISHED
METAL CEILING PANEL
ACCESS NOTES:
1. CLEAR ACCESS OPENING IS 2'-10" BY 2'-0".
2. PROVIDE 2x6 FRAMING BETWEEN CEILING
JOIST TO FRAME OPENING. TYPICAL NEW
CEILING JOIST
EXISTING TRUSS
BOTTOM CHORDS
NEW SIMPSON LUS26 HANGER TO
SUPPORT CEILING JOIST WITH ALL
MFGR. SPECIFIED FASTENERS, TYP.
CEILING PANEL
INSTALL CONTINUOUS
2x6 BETWEEN EXISTING
TRUSS CHORDS
NEW SIMPSON LUS26 HANGER TO
SUPPORT CEILING JOIST WITH ALL
MFGR. SPECIFIED FASTENERS, USE
1-1/2" NAILS INTO TRUSS CHORD, TYP. EXISTING TRUSS
CHORD
EXISTING METAL
SIDING
CEILING PANEL
PRE-FINISHED METAL "J"
CHANNEL EDGE TRIM, TYP.
NEW LIGHT FIXTURE MOUNTED
UNDER TRUSS
(INCLUDED IN ADD ALTERNATE #1)
EXISTING EDGE
PURLIN
EXISTING METAL
ROOFING
EXISTING
METAL SIDING NEW METAL CEILING, BUTT
TIGHT TO METAL SIDING PANEL
EXISTING EDGE
PURLIN
EXISTING METAL
ROOFING
NEW METAL
CEILING PANEL
EXISTING
POST
PRE-FINISHED
"J" CHANNEL
EDGE TRIM
CUT EXISTING METAL
SIDING TO FIT NEW
LOUVER, TYP.
NEW PRE-FINISHED METAL "J"
CHANNEL TRIM AROUND
LOUVER PERIMETER
INSTALL NEW 2x4 BLOCKING AROUND ALL
SIDES OF OPENING BETWEEN TRUSS
WEBS, INSTALL 2x4 FRAMING AROUND ALL
SIDES OF OPENING TO SUPPORT LOUVER
NEW VENTILATION LOUVER,
SEE ELEVATION VIEW FOR SIZE
SHIM AND FASTEN
LOUVER SECURELY
INSTALL BACKER ROD AND
SEALANT AROUND PERIMETER TO
SEAL OPENING WEATHER TIGHT
TH
IS
D R
AW
IN
G
IS
R
ED
U C
ED
IF
B O
R D
ER
IS
N O
T
/2
" x
2"
F4350404
ODOT MITCHELL MAINTENANCE STATION
STORAGE BUILDING CEILING INSTALLATION
17655 HWY 26, MITCHELL, OR 97750 4
04/15/26
FRANCO
JON DOUGHTON S T R U C T U R A L
J A
N U A R Y 1 3 , 2
0 0
DETAILS A103
THICKENED EDGE SLAB (INCLUDED IN ADD ALTERNATE #2)
SCALE: 1" = 1'-0"
A103
TYPICAL CONCRETE SLAB (INCLUDED IN ADD ALTERNATE #2)
SCALE: 3/4" = 1'-0"
2 TYPICAL METAL CEILING
SCALE: 1-1/2" = 1'-0"
ATTIC ACCESS
SCALE: 1-1/2" = 1'-0"
4 NEW CEILING CONNECTION AT TRUSSES
SCALE: 3" = 1'-0"
5 NEW CEILING CONNECTION AT END TRUSS
SCALE: 3" = 1'-0"
REAR CEILING DETAIL
SCALE: 1-1/2" = 1'-0"
7 FRONT CEILING DETAIL
SCALE: 1-1/2" = 1'-0"
8 ATTIC VENTILATION LOUVER DETAIL
SCALE: 1-1/2" = 1'-0"
A103 A103
A103A103A103
A103 A103 A103
REDUCED 50%
WHEN PRINTED
AT 11" x 17"
1 06/30/26 ADD LIGHT FIXTURES TO DETAIL 5/A103 JD
| F4350404 - 04_MITCHELL STORAGE CEILING INSTALL_REV2 PLAN t101.pdf |
| F4350404 - 04_MITCHELL STORAGE CEILING INSTALL_REV2 PLAN 07.13.26.pdf |
| F4350404 - 04_MITCHELL STORAGE CEILING INSTALL_PLAN A101.pdf |
| F4350404 - 04_MITCHELL STORAGE CEILING INSTALL_PLAN A102.pdf |
| F4350404 - 04_MITCHELL STORAGE CEILING INSTALL_PLAN A103.pdf |
| 2026-07-13T10:39:22-0700 | |
| DOUGHTON Jonathan S |
| 2026-07-13T10:41:07-0700 | |
| DOUGHTON Jonathan S |
| 2026-07-13T10:41:49-0700 | |
| DOUGHTON Jonathan S |
| 2026-07-13T10:42:42-0700 | |
| DOUGHTON Jonathan S |
File details come from the government source that posted it. Updated .