Project Grant R41NS129430

Award Date 9/23/22
Completion Date 2/29/24
Dollars Obligated $868K
Federal Grant Program
93.853
Assistance Type
Project Grant
Place of Performance
Louisville, CO 80027, USA
Similar Awards
This National Science Foundation (NSF) Technology, Innovation, and Partnerships (CFDA 47.084) Project Grant of $275,000 awarded to Xtract Medical Inc. aims to develop and demonstrate the feasibility of a novel catheter-based system for improved removal of blood clots during mechanical thrombectomy procedures to treat venous thromboembolism (VTE). The proposed system is designed to effectively remove large blood clots while minimizing damage to blood vessels and reducing complications such as...
This $1,199,991 Project Grant award from the National Science Foundation's (NSF) Computer and Information Science and Engineering (CISE) program aims to develop novel technologies for real-time assessment of blood clot properties to improve stroke treatment. The key products and services under this grant include: Integration of a sub-millimeter Raman fiber probe into a catheter for intravascular, in-vivo measurement of clot chemical composition. Training of a convolutional neural network to...
This Project Grant award from the National Institute of Neurological Disorders and Stroke (NINDS), under the Extramural Research Programs in the Neurosciences and Neurological Disorders (CFDA 93.853) program, provides $1,386,770 to VON Vascular, Inc. to develop a novel aspiration pump for neurointerventional procedures. The goal is to create an improved aspiration pump that can increase first-pass revascularization rates and reduce medical waste, compared to existing market-leading devices....
This Project Grant award from the National Institute of Neurological Disorders and Stroke (NINDS) under the Extramural Research Programs in the Neurosciences and Neurological Disorders (CFDA 93.853) program provides $299,982 to Unandup, LLC to evaluate the safety and efficacy of their novel magnetic infusion platform for accelerating alteplase delivery to acute ischemic stroke clots. The project aims to use an in vivo rat model to support an Investigational Device Exemption (IDE) application for...
This Project Grant from the National Heart, Lung and Blood Institute, part of the Department of Health and Human Services, provides $920,176 under the Cardiovascular Diseases Research program to develop a smart aspiration catheter with fiber optic pressure sensors for mechanical thrombectomy procedures to treat acute ischemic stroke. The catheter will be designed, prototyped and validated at Worcester Polytechnic Institute to provide real-time data to interventionalists on the interaction...
The National Institute of Neurological Disorders and Stroke (NINDS) awarded a $439,239 Project Grant under the Extramural Research Programs in the Neurosciences and Neurological Disorders (CFDA 93.853) to the Beckman Research Institute of the City of Hope. The goal of this 5-year grant, starting on July 1, 2025, is to fabricate and evaluate the feasibility of a novel minimally invasive surgical device termed "REMIDE" that can efficiently and consistently remove intracerebral hematomas....
This $256,000 National Science Foundation project grant supports the development of an automated chest tube to prevent clotting. Circulatech LLC will design and prototype a novel chest tube that proactively manages fluid flow within the catheter lumen to flush and drain the tube, reducing blood clot formation. Through a process called "dilutional coagulopathy," the tube will use sterile saline or anticoagulants to reduce thrombosis in the drainage space rather than relying on...
This $274,547 Project Grant awarded by the National Science Foundation (NSF) under the NSF Technology, Innovation, and Partnerships (CFDA 47.084) program aims to develop a novel Aneurysm Sealing Device (ASD) for endovascular treatment of Abdominal Aortic Aneurysms (AAA). The project seeks to create a device that can completely seal the aneurysm sac, reducing the risk of post-procedure complications and the need for repeat interventions. Key objectives include validating the device's adaptability...
This $490,049 Project Grant award from the National Institute of Neurological Disorders and Stroke (NINDS), under the Extramural Research Programs in the Neurosciences and Neurological Disorders (CFDA 93.853) program, supports research by Shearit LLC to evaluate the efficacy of their Lamiflo drug for reducing ischemic penumbra and core volumes in acute ischemic stroke. The 1-year study will test Lamiflo, a drag-reducing polymer that enhances blood flow, in rat models of middle cerebral artery...
This Project Grant award from the National Institute of Neurological Disorders and Stroke (NINDS), under the Extramural Research Programs in the Neurosciences and Neurological Disorders (CFDA 93.853) program, will support research to characterize and identify patients with poor clinical outcomes despite successful recanalization after endovascular stroke therapy (EVT) for large vessel occlusion acute ischemic stroke. The $2,130,388 award to the University of Texas Health Science Center at...

A NOVEL CLOT CONTAINING SYSTEM FOR IMPROVED NEUROTHROMBECTOMY OUTCOMES - PROJECT SUMMARY MECHANICAL THROMBECTOMY (MT) HAS RECENTLY GAINED IMPETUS AS A TREATMENT FOR ACUTE ISCHEMIC STROKE (AIS). ALTHOUGH TECHNICAL PROGRESS HAS BEEN MADE, THE EFFICACY OF THE CURRENT TECHNIQUES REMAINS SUB-OPTIMAL AND MT IS STILL ASSOCIATED WITH SIGNIFICANT COMPLICATIONS. CURRENT MT TECHNIQUES, USING STENT RETRIEVERS OR ASPIRATION CATHETERS, ACHIEVE SUCCESSFUL REVASCULARIZATION AFTER THE FIRST-PASS ONLY IN LESS THAN 50% OF THE PATIENTS IRRESPECTIVE OF THE TECHNIQUE USED. FURTHER EMBOLIC COMPLICATIONS, WHICH OCCUR IN 10-20% OF CASES, CAUSE SIGNIFICANT SEQUELAE. XTRACT MEDICAL IS DEVELOPING A PATENT-PROTECTED ACCESSORY DEVICE, WHICH IS A NOVEL CLOT CONTAINMENT SYSTEM (CCS) THAT CONSISTS OF AN EXPANDABLE NITINOL BRAIDED TUBE ON THE END OF A GUIDEWIRE THAT IS DELIVERED THROUGH EXISTING NEUROVASCULAR ASPIRATION OR GUIDE CATHETERS. THE BRAID IS COVERED WITH A THIN SILICONE COATING, WHICH BLOCKS THE BLOOD FLOW WHEN IT EXTENDS OUT OF THE DISTAL END OF THE DELIVERY CATHETER AND ADDITIONALLY PROVIDES COMPLETE ENCLOSURE OF THE CLOT DURING EXTRACTION FROM THE PATIENT. AT THE FRONT OF THE BRAID, A CLOSURE WIRE WEAVES THROUGH THE LOOPS IN THE BRAID AND THEN CONNECTS TO THE GUIDEWIRE THAT RUNS THE LENGTH OF THE CATHETER AND OUT OF THE PATIENT. THIS CLOSURE WIRE ACTS AS A SNARE SO THAT WHEN THE CLOSURE WIRE IS ACTUATED BY THE SURGEON THE FRONT END OF THE BRAID CINCHES LIKE A PURSE STRING. XTRACT MEDICAL'S SOLUTION WILL IMPROVE THE EFFICACY OF MT PROCEDURE IN THREE FUNDAMENTAL WAYS: 1) ITS DEPLOYMENT LEADS TO LOCAL BLOOD FLOW ARREST IN THE MIDDLE CEREBRAL ARTERY (MCA). THIS WILL ENHANCE THE ASPIRATION FORCES WHEN IT IS COMBINED WITH AN ASPIRATION CATHETER AND, REGARDLESS OF THE APPLIED MT METHOD, REDUCE DISTAL MIGRATION AND FRAGMENTATION OF THE CLOT. 2) GENTLE EXPANSION OF THE DEVICE IN THE CEREBRAL ARTERY PROXIMAL TO THE CLOT CREATES A LARGER LUMEN SIZE FOR THE CLOT TO BE TRAPPED INTO, INCREASING THE LIKELIHOOD OF THE ENTIRE CLOT REMOVAL BY THE ASPIRATION CATHETER OR STENT RETRIEVER IN THE FIRST PASS. 3) THROUGH ITS UNIQUE CLOSURE SYSTEM, THE DEVICE COMPLETELY CONTAINS THE BLOOD CLOT DURING ITS RETRIEVAL FROM THE BRAIN, PREVENTING THE RELEASE OF CLOT FRAGMENTS AND REDUCING EMBOLIC COMPLICATIONS. IN THIS SBIR PHASE I PROJECT, XTRACT MEDICAL WILL CONDUCT PIVOTAL BENCHTOP STUDIES AND PRE-CLINICAL VALIDATION OF THE EFFICACY AND SAFETY OF ITS ACCESSORY DEVICE. PHASE I (9 MONTHS) IS A FEASIBILITY STUDY DURING WHICH THE PROTOTYPE WILL UNDERGO FURTHER DEVELOPMENT AND VALIDATION IN A BENCHTOP MODEL OF NEUROVASCULATURE (AIM 1) AS WELL AS A PRELIMINARY EVALUATION OF EFFICACY AND SAFETY IN VIVO IN SWINE MODELS (AIM 2). AFTER COMPLETION OF PHASE I, XTRACT MEDICAL WILL PROPOSE A PHASE II SBIR PROJECT FOR THE ESTABLISHMENT OF A QUALITY SYSTEM AND VALIDATION TESTING OF THE DESIGN AND COMPLETION OF PIVOTAL PRE-CLINICAL GLP IN VIVO STUDIES, WHICH WILL LAY THE FOUNDATION FOR XTRACT MEDICAL TO PURSUE FDA CLEARANCE OF ITS DEVICE, AS WELL AS TO ESTABLISH A PATHWAY FOR THE COMMERCIAL LAUNCH OF THEIR DEVICE.

Posted 9/20/22, 12:00 AM