RE-BID San Joaquin Reservoir Valve Actuator Replacement
Closed State & local contract opportunity Posted
- Solicitation number
- 13111
- State
- California
- Responses due
Opportunity facts
- Jurisdiction
- Point of contact
-
- Andres Bernal bernala@irwd.com (949) 453-5431
Opportunity details come from constructionbidsource.com. Updated .
About this opportunity
Orange County, California is requesting bids for replacement and startup testing of San Joaquin Reservoir outlet valve actuators on August 11, 2026. The project spans five actuators at varying elevations along the east reservoir embankment: two positioned above the waterline and three below, plus associated solenoid valves, flow control valves, and ball valves within the valve control cabinet structure. All valve-cabinet components must be replaced in kind to maintain system compatibility.
Work encompasses both submerged and terrestrial environments, requiring contractors with demonstrated experience in reservoir infrastructure maintenance and capability to execute underwater replacement procedures while managing water levels and maintaining system integrity. Startup testing following installation is a core deliverable to verify proper functionality of all replaced components.
The procurement timeline includes a question period (closing date not specified in the source) and an August 11, 2026 proposal due date. This is a re-bid; the source does not identify the incumbent or initial-bid context. No estimated contract value, contract term, or place-of-performance detail beyond the San Joaquin Reservoir site is stated. Evaluation criteria, set-asides, and preference programs are not identified in the source materials provided.
Opportunity text
The project involves replacement and startup testing of the San Joaquin Reservoir outlet valve actuators located along various elevations of the east reservoir embankment, along with the solenoid valves, flow control valves, and ball valves located within the valve control cabinet structure. The two (2) valve actuators with the higher elevations shall be replaced above the reservoir waterline and the three (3) valve actuators with the lower elevations shall be replaced below the reservoir waterline. All valves associated with the valve control cabinet shall be replaced in kind.
Files
| File | Type | Posted |
|---|---|---|
| RE-BID San Joaquin Reservoir Valve Actuator Replacement.pdf |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Similar opportunities
- Ask GovTribe AI about this opportunity