Peace and Prosperity Rehab Program

Closed State & local contract opportunity Posted

Solicitation number
RPQ No PP-009-MC-R
State
Florida
Responses due

Opportunity facts

Jurisdiction

Opportunity details come from constructionbidsource.com. Updated .

About this opportunity

Miami-Dade County Community Action and Human Services Energy Department is requesting sealed bids for the Peace and Prosperity Rehab Program, a comprehensive building rehabilitation at 930 Dunad Avenue, Opa-Locka, Florida, with bids due July 31, 2026 at 2:00 p.m. Attendance at a mandatory pre-bid meeting and site visit on July 21, 2026 at 10:00 a.m. at the project location is required for bid acceptance.

The scope encompasses roofing replacement with pitched deck shingles complying with Miami-Dade County Building Department and Florida Building Code High Velocity Hurricane Zone requirements (including valley, eave drip, plumbing flashing, vents, and soffit ventilation per FBC R806); exterior door replacement; kitchen cabinet and appliance installation; complete bathroom remodeling with ADA compliance; electrical service entrance upgrade to 150 AMP; window replacement with impact-resistant glass; and exterior painting. The general contractor must provide licensed subcontractors for electrical, plumbing, and roofing work. All roofing specifications include detailed material, fastening, and ventilation requirements; the first 100 square feet of damaged or deteriorated sheathing or framing replacement is included in the bid price. Permits for roofing, door, electrical, and plumbing work must be obtained prior to work commencement. Contractors must comply with E-Verify employment eligibility verification and Florida Statute 448.095.

The estimated project value is $68,400 excluding contingencies and allowances. Award will be made to the lowest responsible bidder. The project has an anticipated start date of August 28, 2026 with a 90-calendar-day completion timeline. Monthly scheduled payments are specified. Liquidated damages are assessed at $250 per day for delays. Commercial General Liability insurance of not less than $300,000 per occurrence and $600,000 aggregate, automobile liability of $300,000 combined single limit, and workers' compensation insurance are required, with Miami-Dade County named as additional insured. Performance, payment, and bid bonds are not required.

Opportunity text

***Subcontractor Opportunities***Exterior Repairs: 1) Re-Roof Complete: Pitched Deck Roofing General Specification: All repairs and/or installations of new roof system shall comply with requirements of the MiamiDade County Building Department and The Florida Building Code Test Protocol for High Velocity Hurricane Zones. All valley and eave drips shall be replaced with new and secured with ring shank galvanized nails. Nails shall not penetrate through the sheathing at any visible spot. All plumbing flashing must be replaced with new lead flashing. All vents and stacks protruding through roof shall be replaced with new vents or stacks. End joints shall be made over rafters. Eves drip shall be backed with pressure treated 1X2 furring strips. NOTE #1 Include in your price the 1st 100 sf for replacement of any damaged or deteriorated sheathing or Framing members. NOTE #2 Roof ventilation as per FBC R806.1, R806.2. Replace existing soffit vents with new ones. Ventilation openings shall have a least dimension of 1/16 inch (1.6 mm) minimum and 1/4 inch (6.4 mm) maximum. Ventilation openings having at least dimensions larger Then 1/4 inch (6.4 mm) shall be provided with corrosion-resistant wire cloth screening, hardware cloth, perforated vinyl or similar material with openings having a least dimension of 1/16 inch (1.6 mm) minimum and 1/4 inch (6.4 mm) maximum. NOTE #3 Contractors are responsible for providing all necessary protection from the weather during a phases of roofing operation. NOTE #4 all materials, installation and inspections shall be in accordance with the Florida Building Code and approved by MDC product control division. NOTE #5 Plywood for roof overhang and sheathing, roof sheathing, the FBC R803.2.2 specifies a minimum nominal thickness of 19/32 inch (15 mm). For general roof sheathing, the minimum thickness is 7/16 inches. NOTE #6 Wood Structural Panel Soffits: (FBC) Section 1410.6 Must meet a minimum panel performance category of 3/8, use corrosion-resistant fasteners, and comply with installation guidelines outlined in the code and associated figures, such as placing the strength axis perpendicular to support. Grade and rating: The code requires roof sheathing plywood to be rated for "Exposure 1," which indicates it is suitable for applications where it will be exposed to moisture during construction. A span rating label must also be present on the panels. Provide smooth face plywood for painting

Files

File Type Posted
miami-dade RPQ_No_PP-009-MC-R.pdf PDF

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Similar opportunities
  • Ask GovTribe AI about this opportunity