wavelength meter

Closed Solicitation Posted

Solicitation number
W911S226U2952
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Photonics Research CenterBartlett Hall Science Center, 753 Cullum Rd, Rm 191, West Point, New York 10996

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Army Materiel Command Mission and Installation Contracting Command at Fort Drum is seeking to procure a high-precision wavelength meter capable of measuring wavelengths between 330 and 1180 nanometers. The instrument must deliver varying levels of accuracy depending on the wavelength range, with plus/minus 900 MHz accuracy for wavelengths between 330–375 nm, plus/minus 600 MHz for 375–800 nm, and plus/minus 500 MHz for 800–1180 nm. The wavelength meter must support both continuous-wave and pulsed sources and maintain a minimum measurement speed of 950 Hz, with internal calibration included as a standard feature. This solicitation was posted on April 2, 2026, with proposals due by April 9, 2026, providing a one-week response window for interested contractors to submit their bids.

This opportunity is designated as a Total Small Business set-aside, restricting competition to small business entities. The wavelength meter falls under NAICS Category 334516 (Analytical Laboratory Instrument Manufacturing) and PSC Category 6650 (Optical Instruments, Test Equipment, Components and Accessories). The place of performance is located at 753 Cullum Road, Room 191, West Point, New York 10996. While the solicitation notice does not specify an award value, budget range, or quantity of units required, small businesses meeting the technical specifications and size standards are encouraged to respond within the compressed timeline to participate in this procurement opportunity.

Notice text

High-precision wavelength meterWavelength measurement range 330 -1180 nanometers. Accuracyof plus/ minus 900 MHz for wavelengths between 330 -375 nm. Accuracy of plus/ minus600 MHz for wavelengths between 375 -800 nm. Accuracy of plus/ minus 500 MHz forwavelengths between 800 -1180 nm. Must support both continuous-wave and pulsedsources. Minimum measurement speed of 950 Hz. Internal calibration included.

Similar open opportunities

Opportunity Agency Set-aside Responses due
Wattmeter NAICS 334515 Land and Maritime Total Small Business
Wattmeter NAICS 334515 Land and Maritime Woman-Owned Small Business
Spectrophotometer NAICS 333310 Land and Maritime Total Small Business
Meter, special scale NAICS 334515 Land and Maritime Total Small Business
Meter, special scale NAICS 334515 Land and Maritime No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity