Vault beam design, assembly, and installation at DISA PAC

Awarded Award Notice Posted

Solicitation number
HC1028-16-T-0237
Agency
Defense Information Systems Agency Department of Defense
Awarded
to Cartwright Engineers, PC
Set-aside
Total Small Business

Opportunity facts

Contract number
HC1028-16-P-0127 Federal contract award
NAICS code
561210 Facilities Support Services
PSC
Not on record
Place of performance
Emss Gateway Facility Building 108 Saipan Drive Jbphh, Wahiawa, Hawaii 96786, United States

Notice details come from SAM.gov. Updated .

Notice text

3 versions

Update #3 · Latest ·

Added: Apr 07, 2016 3:24 pm Modified: Apr 29, 2016 3:45 pmTrack Changes Contractor will design, fabricate and install beam assembly to augment existing under floor beam to increase floor load capacity to support 45,000 pounds.  The floor must support a vault that is approximately 13 feet wide by 19 feet long by 9 feet high and weighing 37,000 lbs.  Additional 8,000 pounds will be safes, furniture, shelving and people.

Contractor will provide one hard copy and one soft copy of AutoCAD As-Built drawings for vault and floor reinforcement.  Contractor will provide the following documentation for the project:  a) Vault documentation, b) Framing Plan Elevation and Sections Drawing, c) Structural Notes and Floor Plan, and d) Pounds per sq. ft. rating upon completion of work.

See attached Request for Quote (RFQ), RFQ Instructions, Evaluation Plan, QASP (Quality Assurance Surveillance Plan), and Performance Work Statement (PWS) for detailed information and explanation of the requirements of this RFQ.

Update #2 ·

Added: Apr 20, 2016 3:25 pm Details are included in the RFQ regarding site survey.  Tehre are no drawings or photographs included.  Site surveys are authorized for this solicitation. 

Update #1 ·

Added: Apr 07, 2016 3:24 pm Contractor will design, fabricate and install beam assembly to augment existing under floor beam to increase floor load capacity to support 45,000 pounds.  The floor must support a vault that is approximately 13 feet wide by 19 feet long by 9 feet high and weighing 37,000 lbs.  Additional 8,000 pounds will be safes, furniture, shelving and people.

Contractor will provide one hard copy and one soft copy of AutoCAD As-Built drawings for vault and floor reinforcement.  Contractor will provide the following documentation for the project:  a) Vault documentation, b) Framing Plan Elevation and Sections Drawing, c) Structural Notes and Floor Plan, and d) Pounds per sq. ft. rating upon completion of work.

See attached Request for Quote (RFQ), Evaluation Plan, QASP (Quality Assurance Surveillance Plan), and Performance Work Statement (PWS) for detailed information and explanation of the requirements of this RFQ.

Attachments

Files attached to this notice, newest first
File Type Posted
RFQ_CMT16PCM0012.docx DOCX document
HC1028-16-T-0096-0002.pdf PDF
CLIN_worksheet.xlsx XLSX spreadsheet
CMT16PCM0012_PWS_Revised_20160411.doc DOC document
HC1028-16-T-0237-0001.pdf PDF
HC1028-16-T-0237.pdf PDF
CMT16PCM0012_EPL.xls XLS spreadsheet
Updated_CMT16PCM0012_PWS.doc DOC document
CMT16PCM0012_-_QASP.docx DOCX document
CMT16PCM0012_encl10a_evalplan_rating_lpta.docx DOCX document

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity