Thyroid Uptake System, Poplar Bluff, MO VAMC

Closed Pre-Solicitation Posted

A newer solicitation was posted. See the latest solicitation from .

Solicitation number
36C25525Q0265
Agency
Veterans Integrated Service Network 15 Veterans Health Administration, Department of Veterans Affairs
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
339113 Surgical Appliance and Supplies Manufacturing
PSC
6515 Medical And Surgical Instruments, Equipment, And Supplies
Place of performance
Poplar Bluff, Missouri 63901, United States
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration (VA) is seeking to procure a Thyroid Uptake System for the John J. Pershing VA Medical Center in Poplar Bluff, Missouri. The system is intended for the Nuclear Medicine service to perform diverse nuclear medicine applications, including uptake studies, wipe tests, and bioassay programs. Specific requirements include a multi-purpose spectrum analysis instrument with a touch screen computer, multi-channel analyzer, and 2" x 2" NaI(Tl) integral line scintillation detector. The system must support multiple isotope measurements, provide comprehensive reporting capabilities, and comply with VA technical reference models and IT standards. The pre-solicitation notice indicates a response deadline of March 20, 2025, with potential vendors expected to demonstrate compliance with cybersecurity best practices, equipment compatibility, and provide comprehensive training and support.

There are no specific set-aside designations for this contract opportunity, and no incumbent contractors are mentioned in the documentation. The system will be delivered to the VA Medical Center within 30 days of award, with a one-year warranty and an additional two-year parts/labor warranty. The equipment specifications require a minimum 34-inch articulating arm, compatibility with Windows 10, and the ability to handle various isotopes including I-123, I-125, and I-131. The total system weight should not exceed 350 pounds, with power requirements of 120 VAC, 60 Hz, and a 2 AMP circuit breaker. The procurement falls under the Surgical Appliance and Supplies Manufacturing NAICS category (339113) and the Medical and Surgical Instruments, Equipment, and Supplies PSC category (6515).

Notice text

Statement of Requirement

Thyroid Uptake Unit

John J. Pershing VA Medical Center

  1. GENERAL INFORMATION

TheNuclear Medicine service at John J. Pershing VA Medical Center (VAMC) in Poplar Bluff, MO will better serve its Veterans by acquiring this Thyroid Uptake System with Well Counting System with 2 Inch Well Shielding, a multi-purpose spectrum analysis instrument designed for diverse nuclear medicine applications. The system performs Uptake studies, wipe tests, and other user-defined tasks that are accomplished with speed and precision using this fully integrated computer-controlled instrument and its comprehensive selection of application software.

Engineered for mobility, durability and operational efficiency, the unit handles clinical tests, safety compliance tasks, and system administration procedures quickly and accurately. Built-in menus follow conventionally established nuclear medicine procedures, providing step-by-step guidance throughout defined procedures. The system automatically performs calculations, stores patient information and test results, and outputs clear, concise reports. User-defined uptake protocols can be initiated.

SCOPE         

  1. Delivery of the Thyroid Uptake system will allow a bioassay program for quick and efficient measurement of the staff thyroid burden for radiopharmaceuticals,  I-123,  I-125 and I-131. Measurement results can be reported in cpm, dpm, uCi, or Bq.  Action levels may be set by the user for each isotope. System reporting facilitates single bioassay report, summary of multiple bioassays on an individual staff member, and summary report on multiple staff members. Reports are easily printed or saved as PDF files.
  1. The Thyroid Uptake program supports multiple time-stamped uptake measurements, auto decay correction, user-defined uptake protocols, on-screen spectrum acquisition and analysis. The system provides reports that include normal ranges and allow notes/comments entered by the facility physician and technologists.
  1. The wipe test application automatically calculates net contamination levels and reports results in dpm, uCi and Bq.  The program allows compliance with regulations for counting and reporting results of wipes taken for contamination surveys.  The system allows user to define an unlimited number of “Area” names and wipe “Locations” entered within the areas for testing and documentation.  Each area may be designated as “restricted”, “unrestricted”, “package” or “sealed source”.  The user may specify count times, activity units, wide window, and individual isotopes and geometric efficiencies or simply utilize the wide range of factory default options.
  1. The program displays and stores the full spectrum with each wipe, automatically calculates net contamination levels and reports results in dpm, uCi or Bq. Wipes above the user defined trigger levels are easily identified.  A detailed spectrum analysis may also be performed for any wipe to help identify isotopes causing contamination.  Customized reports can be printed or saved in PDF format.
  1. The application specialist will provide training and guidance to ensure safe use of the equipment and the study and administration applications provided. The contractor will provide cybersecurity best practices information and training, when applicable. 
  1. The contractor will provide application update to ensure information security in the current equipment and other factors that interconnects with the imaging system including the network, other current peripheral applications and other new tools and software that will be developed or installed to work with the current work station and imaging equipment hardware and software.

REQUIREMENT/SALIENT CHARACTERISTICS/SPECIFICATIONS

Common Nomenclature: MEDICAL SPECTROMETER HARDWARE

Kind of material: ALL IN ONE Touch Screen Computer

Electrical Data:

Power: Low voltage transformer with hospital grade power cord and plug.

Line Voltage:

120 VAC, 60 Hz, 2 AMP circuit breaker

230 VAC, 50 Hz, 1 AMP circuit breaker

Dimensions, size, capacity: 

Minimum articulating arm with a minimum of 34 inch vertical range of travel with a minimum of 220 degree collimator rotation.

Principles of operation:  

Multi-Channel Analyzer:

Channels: 1024

Spectral Resolution: FWHM 8%

Count Rate: (Maximum) 150,000 cps for Tc-99m

Count Rate Stability: 99%

Gross Count Rate Linearity: Within 5% up to 150,000 cps

Pulse Height Linearity: Within 2% (independent of detector)

Detector High Voltage Adjustment: Automatic adjustment for both probe and well; uses 10 μCi Cs-137 as the calibration source.

Restrictive environmental conditions: User Set: Unlimited user defined Isotopes, setting ROI, half life, name, efficiency and range.

Intended use: 

Factory Programmed: Au-198, Ba-133, Co-57, Co-58, Co-60, Cr-51, Cs-137, F-18, Fe-59, Ga-67, Ga-68, Gd-153, Ge-68/Ga-68, Hg-197, I-123, I-125, I-131, In-111, Ir-192, K-42, Lu-177, Na-22, Na-24, Pd-103, Ra-223, Se-75, Sr-85, Tc-99m, Tc-99m/Tl-201, Tl-201, Yb-169, Wide Window.

Equipment with which the item is used, Job related tools:

 Probe: 2" x 2" Nal (Tl) integral line scintillation detector

Other pertinent information that describes the item, material or service required:

Uptake Stand:

Dimensions:

Arm down and retracted: 34" l x 26" w x 55" h (86.4 x 66 x 139.7 cm)

Maximum Height: 60" (152.4 cm)

Maximum Length: Arm Extended: 61" (154.9 cm)

Collimated Shield: Flat field collimator meeting IAEA specifications

Positioning: Distance bar and positioning light

Casters: 4" Total locking

Maximum weigh of 300 lbs.

A maximum combined weight with Well Counter: 350 lbs.

Power: Low voltage transformer with hospital grade power cord and plug.

Line Voltage:

120 VAC, 60 Hz, 2 AMP circuit breaker

230 VAC, 50 Hz, 1 AMP circuit breaker

OTHER UNIQUE REQUIREMENTS  :   Minimum of 2 inch well container

Compatibility with Existing Equipment:  TRM Compliance with VA Directives

WINDOWS 10 compatible or Newest Windows Version compliance with VHA standards.

Must be DICOM compliance, Directives or IT Policies, Required.

Coordination with On-going Construction Project (provide the project number): N/A

Warranty: 1 year from date of receipt and verification of installation/operation. Two years part/labor warranty

Training:  Initial installation and launch training staff and service support

Service and/or Maintenance:  Preventive maintenance and training support, to include two Operating Manuals and two Service Manuals

Safety/ISO/IT/BioMed/SPS & Other Departmental Compliance: Must meet Technical Reference Model (TRM) VA/BioMed Compliance.  

DELIVERY

  • Contractor must deliver all components of the system as stated in this solicitation within 30 days of award notice.

Standard FOB Destination to:  John J. Pershing VA Medical Center, 1500 North Westwood Blvd, Poplar Bluff MO 63901.

Government-Furnished Property, Material, Equipment, or Information (GFP, GFM, GFE, or GFI) N/A

SECURITY     N/A

SPECIAL MATERIAL REQUIREMENT   two Operator’s Manuals and 2 Service Manuals

PLACE OF PERFORMANCE

The system will be installed, serviced, and updated at the facility, John J. Pershing VAMC, Poplar Bluff, MO, Nuclear Medicine Department.  Servicing, training, and support of personnel will be per stipulations on the final contract.

Attachments

Files attached to this notice, newest first
File Type Posted
36C25525Q0265.pdf PDF

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Thyroid Uptake System, Poplar Bluff, MO VAMC Latest solicitation Solicitation
Thyroid Uptake System, Poplar Bluff, MO VAMC This notice · Original Pre-Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity