SCOPE OF WORK AAS #171770010
1. The contractor shall inspect the lot of two valves (Model # SA4-03-35-004-15) and provide a list of task to be performed, materials by part number to be replaced.
2. The cost for repair shall not exceed 70% of the cost of a new valve.
3. The contractor shall provide an exterior inspection, looking for damage and leaking.
4. Servo valves will be disassembled and pre-testing of key components like control and power wiring, current/flow, coil independence, motor, and ball weld, etc. parts required for repair as recorded.
5. All new seals & filters ultrasonically are replaced every time.
6. The motors are calibrated every time.
7. All new parts will be provided by the contractor, unless written approval is granted on a case by case basis.
7 Servo valve is cleaned and all required parts are installed.
8 Test each servo valve to OEM specifications.
9 After the valve has passed the testing procedure, package with a service report, test report, Certificate of Conformance, and a one (1) year Warranty of parts and labor. Servo Valve is to be electrostatically packaged and returned.
.

Update #1 ·

Added: Oct 25, 2017 8:40 am SCOPE OF WORK AAS #171770010
1. The contractor shall inspect the lot of two valves (Model # SA4-03-35-004-15) and provide a list of task to be performed, materials by part number to be replaced.
2. The cost for repair shall not exceed 70% of the cost of a new valve.
3. The contractor shall provide an exterior inspection, looking for damage and leaking.
4. Servo valves will be disassembled and pre-testing of key components like control and power wiring, current/flow, coil independence, motor, and ball weld, etc. parts required for repair as recorded.
5. All new seals & filters ultrasonically are replaced every time.
6. The motors are calibrated every time.
7. All new parts will be provided by the contractor, unless written approval is granted on a case by case basis.
7 Servo valve is cleaned and all required parts are installed.
8 Test each servo valve to OEM specifications.
9 After the valve has passed the testing procedure, package with a service report, test report, Certificate of Conformance, and a one (1) year Warranty of parts and labor. Servo Valve is to be electrostatically packaged and returned.