PN 87539 SOF Operations Facility Secure Work Area

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
W912PM19R0019
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Ft Bragg, NC Ft Bragg NC 28307 USA

Notice details come from SAM.gov. Updated .

About this opportunity

This pre-solicitation notice seeks information from contractors interested in renovating an existing facility into a secure work area meeting ICD 705 standards for the U.S. Army Corps of Engineers, Wilmington District. The project includes renovating the space into private and semi-private offices, expanding latrines, installing a divisible 120 person classroom, VTC spaces, and upgrading the HVAC system to meet secure compartmented information facility requirements. Interested parties must provide responses by April 16, 2019 detailing their experience constructing similar secure facilities, bonding capacity, and ability to perform the work, which includes a projected value between $5-10 million.

The opportunity is set aside as a total small business and targets NAICS code 236220, with a PSC code S206. Respondents must detail if they are a HUB Zone, 8(a), Service Disabled Veteran Owned Small Business, Small Disadvantaged Business, or Woman-Owned Business. The renovation must be completed to a 40 year minimum life and incorporate energy efficiencies, building envelope, and integrated systems in compliance with DoD sustainability requirements.

Notice text

SOURCES SOUGHT NOTICE
PN 87539
W912PM19R0019
SOF Operations Facility Secure Work Area
Fort Bragg, North Carolina


This is a Sources Sought/Request for Information only. This is NOT a Solicitation Announcement, nor is it a Request for Proposal. This request does not obligate the Government in any contract award.

The U.S. Army Corps of Engineers, Wilmington District, is conducting research to determine the market capabilities of potential contractors to construct Project Number 87539, SOF Operations Facility Secure Work Area. The project includes renovation of an existing non-secure working area into a secure working area meeting ICD 705 requirements with private and semi-private offices, expanded Male/Female latrines, dividable 120 PN Classroom, VTC spaces, and upgraded HVAC system. Provide for STC-50 rated walls, doors, ceiling and floors, fire suppression; fire alarm, mass notification and security measures. Installation of cybersecurity measures including identity assurance and operational resilience to fire life safety systems, building automation (EMCS/UEMCS) systems, and electronic access control systems, integrated commercial intrusion detection security systems (CCTV, IDS), cable TV, a protected distribution system, and connection to the energy management control system. Provide sustainability/energy measures and building information systems. Access for individuals with disabilities will be provided. Furniture and equipment, comprehensive interior design, electronic security systems, and audio visual services are included. Existing facility construction consists of composite concrete floor slab with a steel rigid frame structure. Department of Defense principles for high performance and sustainable building requirements will be included in the design and construction of the project in accordance with federal laws and Executive Orders. Heating and air conditioning will be provided by two (2) self-contained systems. One system for the Secure Working Area and a separate system for the Team Room Vault. Facilities will be designed to a minimum life of 40 years in accordance with DoD's Unified Facilities Criteria (UFC 1-200-02) including energy efficiencies, building envelope and integrated building systems performance.
In accordance with DFARS 236.204(i) the magnitude of construction for this project will be between $5,000,0000.00 and $10,000,000.00.

All interested firms with 236220 as an approved NAICs code have until 11 APRIL 2019 at 2:00 p.m. to submit the following information:

- Name & Address of your Firm

- Point of Contact (Name/Phone/E-mail)

- Current System for Award Management (SAM) registration information

- Business Size, to include designation as HUB Zone, 8(a), Service Disabled Veteran Owned Small Business, Small Disadvantaged Business, Woman-Owned Business, and Large Business. [If an 8(a) Small Business, your firm must have an office in Region IV (GA, AL, NC, VA, TN, MS, FL, KY, SC)]. Any supporting documentation that confirms your socio-economic status should be provided, e.g., letter of certification from VA confirming SDVOSB status. The Government must be able to verify SBA certification of Hub Zone and 8(a) via SAM.

- Bonding capability - both single and aggregate capacity contracts or for multiple task orders, as evidenced by submission of Surety Company Letter stating bonding capacity.

- Evidence of capabilities to perform comparable work (i.e., construction of a secure work area) of similar size, scope and complexity on three (3) but no more than five (5) recent projects equal to or greater than $3,500,000.00 in value (not more than six (6) years old) and a minimum of 6,750 Square Feet in area. Two (2) projects must include evidence of the construction of similar Sensitive Compartment Information Facility (SCIF) construction projects constructed at ICD 705 Standards. Projects may include construction of a Sensitive Compartment Information Facility (SCIF) where the entire facility is a SCIF. All project examples submitted must be as the prime contractor, Joint Venture or Mentor Protégé. Include the project name and description of the key/salient features of the project (i.e., square footage, multi-story, phased renovation, etc.), completion date, total contract construction value, whether it was Design-Build, Construction only, Renovation or Rehabilitation, etc. Additionally, if you were teaming with another firm, clearly identify your role on the project(s) submitted. Please provide at least one point of contact (with e-mail address and phone number) for project validation. The Government will not give credit to projects if the lack of information hinders the ability to determine relevancy and/or level or experience.

- Firm's capability to perform, to include geographic span and project size. If firm has personnel with active security clearances, please provide employee name, level of clearance, and expiration date of clearance.

- Information on Teaming Arrangement (if applicable). Although we are not looking for formal signed agreements at this time, if you intend to "team" with another firm, formally or informally, you must submit information, not more than one (1) page, about your team's involvement. More specifically, you must submit sufficient information for the Government to determine the roles each team member will play and what your socio-economic status is or will be considering the proposed arrangement. Therefore, included in your one (1) page if you are a Small Business and you intend to mentor/protégé and/or JV with a large business both team members must sign agreeing that 40% of the labor will be performed by the protégé firm. Additionally, if the team is a mentor/protégé arrangement, identify the areas that will be mentored. If the offeror is a Joint Venture (J-V), relevant project experience should be submitted for projects completed by the Joint Venture entity, or the individual firms that make up the joint venture. Offerors that are part of the DoD Mentor Protégé program may submit two (2) recent and relevant projects completed by the Mentor with the remaining project being submitted on behalf of the protégé. Any supporting documentation that confirms your socio-economic status as a team should be provided.

The Government may not give credit to your socio-economic class if there is not sufficient documentation to support it or if the Government cannot verify through other means that your business is as such.

Noting your company as an interested party does not fulfill the Contracting Officer's need for information. Please be sure to submit all of the information requested above directly to the individuals shown below.

The requested information shall be submitted electronically to:

U.S. Army Corps of Engineers
Attn: Jere West
Email: jere.f.west@usace.army.mil

and

U.S. Army Corps of Engineers
Attn: Drew Cranford
E-mail: andrew.cranford@usace.army.mil

The email should be entitled: PN 87539 SOF Ops Fac Secure Work Area

Do not send hard copies of advertising or promotional materials. Please ensure that all responses are comprehensive and provide a name and point-of-contact for your firm for follow-up by this office or the procuring contracting officer. If you have responded to any previous e-mail messages or had other communications with our office regarding preliminary market research for this project, please be advised that it will be necessary for you to respond to this e-mail and the questions contained therein. Any responses involving teaming agreements should delineate between the work that will be accomplished by the Prime Contractor and work accomplished by the teaming partner

All information is to be provided on a voluntary basis at no charge to the Government. There is no entitlement to payment of direct or indirect costs related to or arising out of responding to this request for information. All information provided becomes property of the Government. There is no guarantee, expressed or implied, that the market research for this acquisition will result in any guarantee of award or acquisition strategy.

Notice history

Notice Type Posted
PN87539 SOF Operations Facility Secure Work Area Award Award Notice
PN87539 SOF Operations Facility Secure Work Area Latest solicitation Solicitation
PN87539 SOF Operations Facility Secure Work Area Pre-Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Sources Sought - Construction Repair Building 6413 Secure Space (511669 & 519580) Barksdale AFB Barksdale AFB, Louisiana 71110, United States · NAICS 236220 ENDIST Fort Worth No set-aside
Repair Naval Reserve Training Facility B3370 Charleston AFB, South Carolina 29404, United States · NAICS 236220 Air Mobility Command Total Small Business
PKA Relocatable Facility FE Warren AFB, Wyoming 82005, United States · NAICS 332311 Global Strike Command Total Small Business
Interior Secure Area Enclosure 7288 Convoy Terrace, San Diego, CA 92111 92111 Army National Guard No set-aside
REQUEST FOR INFORMATION (RFI) / MARKET RESEARCH NOTICE RELATED TO SEVERAL UPCOMING PROJECTS at WRIGHT-PATTERSON AFB, OHIO Wright Patterson AFB, Ohio 45433, United States · NAICS 236220 ENDIST Louisville No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity