Mobile Launcher 1 Modifications for Artemis II and Emergency Egress System Installation
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 80KSC02R0022
- Agency
-
Kennedy Space Center
National Aeronautics and Space Administration
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238120 Structural Steel and Precast Concrete Contractors
- Place of performance
- Florida 32899, United States
Notice details come from SAM.gov. Updated .
About this opportunity
This solicitation seeks proposals to modify Mobile Launcher 1 and install an emergency egress system at the Kennedy Space Center in Florida to support the Artemis II mission. The National Aeronautics and Space Administration is procuring these services. Offerors must be certified through the Defense Logistics Agency Joint Certification Program to obtain controlled technical documents. The work includes structural modifications, adding platforms, ground cooling systems, fire detection and suppression updates, installing camera and facility systems, and developing new cables. Proposals are due by June 23, 2021.
There is no set-aside designation. The primary NAICS code is 237990 and PSC code R499. The incumbent is expected to furnish all necessary labor, equipment, materials and activities to complete the work within 330 calendar days at the Kennedy Space Center in Florida. The value is undetermined but includes structural modifications, relocating facilities, and installing multiple systems on Mobile Launcher 1 to ready it for crewed launch.
Notice text
3 versions
Update #3 · Latest ·
All Specifications and Drawings have an Export Determination of EAR 99 and are considered controlled documents. The drawings and specifications will be limited to vendors certified by Defense Logistics Agency (DLA) Joint Certification Program (JCP). To request the controlled documents, interested vendors must submit an email to the listed POCs, C. M. Julius Williams and Tony Caruvana at the following addresses: christopher.m.williams@nasa.gov and anthony.m.caruvana@nasa.gov. The email request must include the vendors CAGE and/or JCP Certification Number. The POCs will verify the vendor has an approved JCP by utilizing the DLA JCP Search at: https://public.logisticsinformationservice.dla.mil/jcp/search.aspx. After verifying the vendor has an approved JCP certification, they will send the documents via an approved large file transfer service (NOMAD, Box, etc.).
The contractor shall furnish all labor, equipment, materials, and related activities necessary to Modify Mobile Launcher-1 for Artemis II and Install the Emergency Egress System at Kennedy Space Center, Florida.
The task associated with the proposed work includes, but is not limited to, the following:
Structural modifications to ML-1 to add platforms for the emergency egress system, adding ground cooling systems, relocating a rest room, adding fire detection systems, modifying the fire suppression systems, camera systems, and other facility systems, and building and installing new cables that are potted and molded for several critical systems including the launch release system, hazardous gas detection system in order to safely launch astronauts for Artemis II. The scope also includes all other incidental related work.
The purpose of Amendment 0001 is to:
A) Update the proposal due date to June 16, 2021 by 11:00AM EST.
B) Update Attachment J-F, Section C.2 List.
C) Add Specification K0000417797-08 22 20, Bathroom Door Specification.
D) Update Attachment J-C, Wage Determination.
E) Provide Virtual Site Visit Roster.
F) Provide Site Visit Sign in Sheet.
G) Update the Question Submission date to June 01, 2021.
The purpose of Amendment 0002 is to:
A) Update the proposal due date to June 23, 2021 by 11:00AM EST.
B) Update Section J.1 List of Attachments.
C) Add Attachment J-G, Section C.2(b) MIP & Coating Specification Corrections.
D) Update Section C.2 paragraph (b).
E) Provied Government answers to submitted questions.
Update #2 ·
All Specifications and Drawings have an Export Determination of EAR 99 and are considered controlled documents. The drawings and specifications will be limited to vendors certified by Defense Logistics Agency (DLA) Joint Certification Program (JCP). To request the controlled documents, interested vendors must submit an email to the listed POCs, C. M. Julius Williams and Tony Caruvana at the following addresses: christopher.m.williams@nasa.gov and anthony.m.caruvana@nasa.gov. The email request must include the vendors CAGE and/or JCP Certification Number. The POCs will verify the vendor has an approved JCP by utilizing the DLA JCP Search at: https://public.logisticsinformationservice.dla.mil/jcp/search.aspx. After verifying the vendor has an approved JCP certification, they will send the documents via an approved large file transfer service (NOMAD, Box, etc.).
The contractor shall furnish all labor, equipment, materials, and related activities necessary to Modify Mobile Launcher-1 for Artemis II and Install the Emergency Egress System at Kennedy Space Center, Florida.
The task associated with the proposed work includes, but is not limited to, the following:
Structural modifications to ML-1 to add platforms for the emergency egress system, adding ground cooling systems, relocating a rest room, adding fire detection systems, modifying the fire suppression systems, camera systems, and other facility systems, and building and installing new cables that are potted and molded for several critical systems including the launch release system, hazardous gas detection system in order to safely launch astronauts for Artemis II. The scope also includes all other incidental related work.
The purpose of Amendment 0001 is to:
A) Update the proposal due date to June 16, 2021 by 11:00AM EST.
B) Update Attachment J-F, Section C.2 List.
C) Add Specification K0000417797-08 22 20, Bathroom Door Specification.
D) Update Attachment J-C, Wage Determination.
E) Provide Virtual Site Visit Roster.
F) Provide Site Visit Sign in Sheet.
G) Update the Question Submission date to June 01, 2021.
Update #1 ·
All Specifications and Drawings have an Export Determination of EAR 99 and are considered controlled documents. The drawings and specifications will be limited to vendors certified by Defense Logistics Agency (DLA) Joint Certification Program (JCP). To request the controlled documents, interested vendors must submit an email to the listed POCs, C. M. Julius Williams and Tony Caruvana at the following addresses: christopher.m.williams@nasa.gov and anthony.m.caruvana@nasa.gov. The email request must include the vendors CAGE and/or JCP Certification Number. The POCs will verify the vendor has an approved JCP by utilizing the DLA JCP Search at: https://public.logisticsinformationservice.dla.mil/jcp/search.aspx. After verifying the vendor has an approved JCP certification, they will send the documents via an approved large file transfer service (NOMAD, Box, etc.).
The contractor shall furnish all labor, equipment, materials, and related activities necessary to Modify Mobile Launcher-1 for Artemis II and Install the Emergency Egress System at Kennedy Space Center, Florida.
The task associated with the proposed work includes, but is not limited to, the following:
Structural modifications to ML-1 to add platforms for the emergency egress system, adding ground cooling systems, relocating a rest room, adding fire detection systems, modifying the fire suppression systems, camera systems, and other facility systems, and building and installing new cables that are potted and molded for several critical systems including the launch release system, hazardous gas detection system in order to safely launch astronauts for Artemis II. The scope also includes all other incidental related work.
Files
Show all 19
Notice history
| Notice | Type | Posted |
|---|---|---|
| Mobile Launcher 1 Modifications for Artemis II and Emergency Egress System Installation | Award Notice | |
| This notice | Solicitation | |
| Mobile Launcher 1 Modifications and Emergency Egress System Installation for Artemis II | Pre-Solicitation | |
| Mobile Launcher 1 Modifications for Artemis II and Emergency Egress System Installation | Pre-Solicitation |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity