MMD hydraulic fluid removal and replacement

Award Notice Posted

Solicitation number
W912P4-16-T-0011
Agency
Awarded
to Michaelson Fluid Power, Inc.
Set-aside
No set-aside

Opportunity facts

Contract number
W912P416P0015 Federal contract award
NAICS code
811310 Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
PSC
Not on record
Place of performance
Willim B. Howyt II Visitor Center, 6103 Visitor Center Road. Mount Morris, New York 14510, United States

Notice details come from SAM.gov. Updated .

Notice text

The contractor shall perform the following work under this contract: Remove and replace approximately 3,600 gallons of hydraulic fluid. The hydraulic power system at Mount Morris Dam consists of a 750 gallon tank, eighteen
(18) 24" diameter bore by 7' 2 13/16" stroke cylinders, and approximately 1,400 total feet of both 2" XXS and SCH 40 pipe. It is estimated there is 300 gallons of fluid in the tank when all cylinders are extended and an additional 140 gallons when all cylinders are retracted. The contractor shall replace approximately 3,600 gallons of fluid with mobil DTE 10 Excel Series ISO 32, or approved equal fluid. If the contractor.
PRE-BID SITE VISIT
There will be one (1) scheduled pre-bid site visit for prospective bidders.The date and time of the visit will be February 3, 2016 at 10:00 A.M., at the William B. Hoyt II Visitor Center, 6103 Visitor Center Road. Mount Morris, New York 14510. Prospective bidders are urged to attend to gain information that will be necessarry in preparation of bid submittals. Please contact Dorothy Jones if you plan to attend. (Please read attached Statement of Work (SOW) for more detailed information.