About this opportunity

This solicitation seeks design-build services to renovate an existing administrative building at Fort Meade, Maryland into a Sensitive Compartmented Information Facility. The Department of the Army Corps of Engineers Engineering District Baltimore will evaluate proposals and award a firm-fixed-price contract to repair and replace site, architectural, mechanical, electrical, security and interior/exterior finishes. Proposals are due by October 22, 2021 and the selected contractor must complete all work within 730 calendar days of notice to proceed. Evaluation criteria include technical approach, past performance, and price.

There is no set-aside designation for this procurement. The primary NAICS code is 238210 and PSC code R499 apply. The total contract value is estimated between $10-25 million. The place of performance is the existing administrative building at Fort Meade, Maryland. The contract has a maximum period of performance of 730 calendar days from the notice to proceed date to complete all required repairs, renovations, demolition and new construction work.

Notice text

This design-build project includes repairs to existing failed or failing site, architectural, mechanical, electrical, telecommunication, fire alarm, security, plumbing, roofing and structural building systems. A failed flat roof will be replaced with a sloped metal roof, and the exterior will be clad in a red brick system to reduce life cycle maintenance costs and meet the requirements of the Installation Planning Standard. Demolition will include all but the concrete structure. The programmatic design assumes the existing exterior masonry infill will also remain.

Replace all interior and exterior finishes, partitions, doors and windows. Remove all fan coil units, associated dual temperature piping, condensate drain lines, thermostats, controls and dryer vent ducts. Remove all plumbing fixtures, sinks vanities, water closets, urinals, toilet partitions, toilet accessories and associated sanitary lines, vent lines, water lines and valves. Remove electrical panelboards, switchboards, circuit breakers, conduit, conductors, receptacles, switches, and lighting fixtures. Remove the electrical service entrance, primary underground ductbank, pad mounted utility service transformer, secondary underground distribution, and metering equipment. Remove the pole mounted light fixture in the parking lot. Remove telecommunication cabling, conduit, pathways, equipment racks, and jacks. Remove telecommunication outside plant cabling and ductbanks. Remove electronic security systems such as intrusion detection system, closed circuit television systems, and headend equipment. Remove fire alarm system and all communications systems.

Provide all HVAC, Electrical, Structural, Plumbing, Communications, Electronic Security, and Fire Protection systems, fixtures, partitions, finishes and accessories to provide the finished condition described in this document. Finished condition will comply with current building standards, codes, laws, and regulations. Life safety improvements will be consistent with the Reconstruction category of Building Rehabilitation.

Files

File Type Posted
W912DR21R0071 FINAL.pdf PDF
W912DR21R0071.pdf PDF

Notice history

Notice Type Posted
Marforcyber – B8605 renovation DB project, fort meade, MD Award Award Notice
Marforcyber – B8605 renovation DB project, fort meade, MD Latest solicitation Solicitation
This notice Solicitation
Marforcyber – B8605 renovation DB project, fort meade, MD Pre-Solicitation
Marforcyber – B8605 renovation DB project, fort meade, MD Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Design-Build Maintenance and Repair Army Reserve (MRAR) of Equipment Concentration Site (ECS), B-56767, at North Fort Hood, TX Bldg. 56767 Equipment Concentration Site (ECS) #6428th St. and Park Ave.North Fort Hood, TX Gatesville, Texas 76528, United States · NAICS 236220 ENDIST Louisville Total Small Business
Y1DA--512A5-22-700 | EHRM Infra Upgrades | Perry Point, MD CO: Samantha Mihaila CS: Ric Sochor Perry Point Vamc · NAICS 236220 VA Technology Acquisition Center Service-Disabled Veteran-Owned Small Business
Armed Forces Recruiting Building 25 Tenant Improvement and Renovation Project- Sources Sought Notice Lakewood, Colorado 80226, United States · NAICS 236220 — No set-aside
ICD-705 Controlled Spaces Modernization and Sustainment Program - (Progressive Design-build (PDB) Other Transaction Agreement (OTA) Osan Air Base Korea, South · NAICS 236220 ENDIST Far East No set-aside
613-22-700 | EHRM Infrastructure Upgrades Construction | Martinsburg, WV West Virginia 25405, United States · NAICS 236220 VA Technology Acquisition Center No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity